NAEROBIC MEMBRANE BIOREACTOR NEW BUT NOT BORN …

Post on 23-Mar-2022

5 views 0 download

transcript

ANAEROBIC MEMBRANE BIOREACTOR -

NEW, BUT NOT BORN YESTERDAY…

Alzbeta Bouskova (Ph.D.) – BPO Ltd.

Shannon Grant (MScE, MBA, PEng), Dwain Wilson (MScE, PEng), Mike Allison (MScE) – ADI Systems

LOW-RATE MEDIUM-RATE HIGH-RATE

ANAEROBIC DIGESTER TYPES

HIGH_RATE

LOW-RATE

MEDIUM-RATE

HIGH-RATE

LOW-RATE MEDIUM-RATE HIGH_RATE

PRE-TREATMENT REQUIREMENTS

ANAEROBIC MEMBRANE BIOREACTOR (ANMBR)

CSTR Digester

Membrane Filtration

influent

permeate

sludge

✓ VERSATILE

✓ HIGHLY EFFICIENT

✓ COMPACT

✓ ROBUST

✓ RELIABLE

✓ FLEXIBLE

An

MB

R

An

MB

R

KEN’S FOODS, MA (US)

Parameter Influent

Flow (m3/d) 380

COD (mg/l) 37,400

BOD (mg/l) 18,000

TSS (mg/l) 11,500

FOG (mg/l) 840

Operating results and photographs in this presentation are the property of ADI Systems Inc.

ADI-

BVF®

(8,300 m3)

ADI-SBR(1,300 m3)

AnMBR

Existing

Building

BVF Effluent

Final Effluent to

Municipal Sewer

EQ

Tank

Ken’s Foods Inc. Site Plan

Sludge

Recycle

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Ken’s Foods Inc. Process Flow Diagram

CHEMICALFEED

BARREL

POTABLE WATER

INJECTIONBLENDER

TO AnMBRs CHEMICAL CLEANING SYSTEM

BIOGAS TO

EXISTING BIOGASSYSTEM

VFD VFD VFD

BIOGAS SCOURBLOWERS

DENOTES PREVIOUSLY EXISTING

EFFLUENT FROMEXISTING ADI-BVF®REACTOR

VFD

EXISTINGADI-SBR AS

SO TANK(0.36 MG)

EFFLUENTTO POTW

WANS/RANS TO EXISTINGADI-BVF® REACTOR OR

CENTRIFUGE

VFD VFD VFD VFD

TO SBR SLUDGEWASTING PUMP

ANAEROBICMEMBRANE

TANKNo. 1

ANAEROBICMEMBRANE

TANKNo. 2

ANAEROBICMEMBRANE

TANKNo. 3

ANAEROBICMEMBRANE

TANKNo. 4

PERMEATEPUMPS

SLUDGE RECYCLE

FM FM FM FM

Operating results and photographs in this presentation are the property of ADI Systems Inc.

0.0001

500.0001

1000.0001

1500.0001

2000.0001

2500.0001

3000.0001

3500.0001

4000.0001

4500.0001

0

10,000

20,000

30,000

40,000

50,000

60,000

70,000

80,000

90,000

100,000

1/08/2008 1/08/2009 1/08/2010 1/08/2011 1/08/2012 1/08/2013 1/08/2014 1/08/2015 1/08/2016

An

MB

R E

fflu

en

t C

OD

(m

g/l)

RW

W C

OD

(m

g/l)

RWW COD AnMBR Effluent COD

Operating results and photographs in this presentation are the property of ADI Systems Inc.

0

50

100

150

200

250

300

350

400

450

500

0

5,000

10,000

15,000

20,000

25,000

1/08/2008 1/08/2009 1/08/2010 1/08/2011 1/08/2012 1/08/2013 1/08/2014 1/08/2015 1/08/2016

An

MB

R e

fflu

ent

TSS

(mg/

l)

RW

W T

SS (

mg/

l)

RWW TSS AnMBR Effluent TSS

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Parameter Influent Effluent Removal

Flow (m3/d) 380 380 -

COD (mg/l) 37,400 250 99.3%

BOD (mg/l) 18,000 25 99.9%

TSS (mg/l) 11,500 <3 ~100%

FOG (mg/l) 840 nil ~100%

✓ AnMBR allowed 60% load increase

✓ Improved effluent quality

✓ >8 years in operation with no membrane failure

✓ Consistent performance (pH 7.0 ± 0.1, VA/PA ratio 0.4 ± 0.2)

KEN’S FOODS, MA (US)

Operating results and photographs in this presentation are the property of ADI Systems Inc.

CONFECTIONERY MANUFACTURING PLANT (US)

Parameter Influent

Flow (m3/d) 170

COD (mg/l) 16,000

BOD (mg/l) 8,000

TSS (mg/l) 10,000

Operating results and photographs in this presentation are the property of ADI Systems Inc.

ANAEROBIC CSTR

(1,360 m3)

MICRONUTRIENTS

ANAEROBICMEMBRANE

TANK

VFD

VFD

BIOGAS TO

EXISTING BIOGASSYSTEM

VFD

VFD

DEFOAMER

DEGASSIFIER EFFLUENT TO DISCHARGE

WASTE ANAEROBIC SLUDGE

CIP

SPENT CHEMICALS

PERMEATE PUMPS

SCOUR BLOWERS

SLUDGE RECYCLE

Confectionery Plant Process Flow Diagram

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Operating results and photographs in this presentation are the property of ADI Systems Inc.

CONFECTIONERY MANUFACTURING PLANT (US)

Parameter Influent Effluent Removal

Flow (m3/d) 155 155 -

COD (mg/l) 12,000 350 >97%

BOD (mg/l) 4,400 30 >97%

TSS (mg/l) 1,200 nil ~100%✓ AnMBR allowed to double the load

✓ Improved effluent quality

✓ Membrane cleaning every 6 months (>4 years of operation)

✓ Consistent performance

Operating results and photographs in this presentation are the property of ADI Systems Inc.

KELLOGG COMPANY PIKEVILLE PLANT(US)

Parameter Influent

Flow (m3/d) 75

COD (mg/l) 34,500

BOD (mg/l) 17,000

TSS (mg/l) 1,600

Operating results and photographs in this presentation are the property of ADI Systems Inc.

MBR

An-CSTR(450 m3)

Pre-Aeration

(340 m3)

ANMBR

Final Effluent tochlorination/de-chlorination

BIOGAS SCOUR BLOWERS

AERATIONBLOWERS

MBR Recycle

MBR Recycle

AnMBRPermeate

Aerobic Permeate

Influent from Holding Tank

Air Scour

To MBR Compartment

EQ Tank(75 m3)

HT

Process Flow Diagram for Kellogg Kimper WWT

SANITARY WW

PERMEATEPUMPS

RECYCLEPUMPS

RWW

Operating results and photographs in this presentation are the property of ADI Systems Inc.

0

200

400

600

800

1,000

1,200

1,400

1,600

1,800

0

5,000

10,000

15,000

20,000

25,000

30,000

35,000

40,000

45,000

15-Aug-2015 15-Nov-2015 15-Feb-2016 15-May-2016 15-Aug-2016 15-Nov-2016

Effl

ue

nt

CO

D c

on

cen

trat

ion

s (m

g/l)

RW

W C

OD

(m

g/l)

RWW COD (mg/l) ADI-AnMBR Effluent COD ADI-MBR Effluent COD

Operating results and photographs in this presentation are the property of ADI Systems Inc.

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

11.0

12.0

01-Jul-15 28-Nov-15 26-Apr-16 23-Sep-16 20-Feb-17 20-Jul-17

pH

Inf. pH AnMBR pH MBR pH

Operating results and photographs in this presentation are the property of ADI Systems Inc.

KELLOGG COMPANY PIKEVILLE PLANT

Parameter Influent AnMBR Effluent Removal

Flow (m3/d) 75 75 -

COD (mg/l) 34,500 380 >97%

BOD (mg/l) 17,000 N.A. -

TSS (mg/l) 1,600 nil ~100%✓ AnMBR allowed to increase the load

✓ Maximised use of existing equipment

✓ Improved effluent quality

✓ Reduced operating input demand (from 4 operators 24/7 to 2 operators 12/7)

✓ Consistent discharge quality compliance

Operating results and photographs in this presentation are the property of ADI Systems Inc.

Project COD Load (kg/d)Construction Start

(Year)Wastewater Type

Ken’s Foods Inc. (USA) 18,500 2008 Salad Dressings

Plant A*** (USA) 48,000 2011 Supermarket Food Waste

Y&S Candies (USA) 2,700 2012 Confectionery

Kellogg Company (USA) 3,200 2012 Bakery

Plant B*** (USA) 20,440 2015 Supermarket Food Waste

Ken's Foods Inc. (USA) 45,420 2016 Salad Dressings

Operating results and photographs in this presentation are the property of ADI Systems Inc.

ANAEROBIC MEMBRANE REACTOR TECHNOLOGY

✓ Proven technology

✓ Versatile use

✓ Reliable operation

✓ Improves plant operability

✓ Compact and modular