Post on 27-Oct-2014
transcript
Version 6.00
SCANNER GUIDE
© 2011 by Anite Finland Ltd. All rights reserved.
This manual, as well as the software described in it, is furnished under license and may only be used
or copied in accordance with the terms of such license. The information in this manual is intended for
informational use only and is subject to change without notice. Anite Finland Ltd assumes no
responsibility or liability for any errors or inaccuracies that may appear in this user manual.
Except as permitted by such license, no part of this publication may be reproduced or transmitted in
any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written
permission of Anite Finland Ltd.
Windows®, Windows® XP, Windows® Vista, Windows® 7, Outlook®, and Internet Explorer are
registered trademarks of the Microsoft® Corporation in the United States and other countries.
MapInfo® and MapX® are registered trademarks of MapInfo® Corporation. CDMA 2000® is a
registered trademark of the Telecommunications Industry Association (TIA -USA). The license
management portion of this Licensed Technology is based on SentinelLM* © 1989-2003 Rainbow
Technologies, Inc. All rights reserved.
Revision 6.00.01, Last edited July 2011
NEMO SCANNER G UIDE 3
CONNECTING DEVICES 4
Connecting Nemo FSR1 Scanner 4
Connecting Anritsu Scanners 8
Connecting the DRT Wimax 4301A+ Scanner 17
Connecting the PCTEL LX CDMA/EVDO/GSM/WCDMA Scanner 20
Connecting PCTEL EX scanners 22
Connecting the PCTEL LX GSM/WCDMA Dual-Mode Scanner 26
Connecting the PCTEL MX GSM/WCDMA Scanner 29
Connecting PCTEL PCT Scanners 32
Connecting the Rohde & Schwarz TSMQ/TSML Scanner 35
Connecting the Rohde & Schwarz TSMW Scanner 39
STARTING DEVICES 43
Starting Nemo FSR1 Scanner 43
Starting Anritsu Scanners 45
Starting DRT Scanners 47
Starting PCTEL Scanners 49
Starting Rohde & Schwarz Scanners 55
STARTING MEASUREMENT 56
Nemo FSR1 Scanner 56
Anritsu Scanners 67
PCTEL Scanners 81
DRT Scanners 102
Rohde & Schwarz TSMQ/TSML/TSMW Scanners 107
TROUBLESHOOTING SCANNERS 119
NEMO SCANNER G UIDE 4
CONNECTING DEVICES
CONNECTING NEMO FSR1 SCANNER
Nemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone receiver is
achieved by using the optional AC power supply. The AC power supply is designed to work with
100 - 240VAC 50/60Hz. For other voltages or line frequencies contact Anite for the correct
supply.
The standard AC supply is rated at 130 Watts. Actual power requirements will vary depending
number of downconverters installed and the receiver tasking. The maximum power requirement
of the scanner is 50 Watts.
DC operation for the standalone receiver can be achieved by connection to a vehicle 12-volt
system. The following table is provided to budget the system current requirements for various
configurations.
Platform configuration/Module 12 VDC current requirement
Basic system w/ single downconverter 3.0 A
Two downconverter system 3.6 A
The estimates given for the scanner assume maximum utilization of the processing capabilities.
Connecting the Nemo FSR1:
1. Connect an antenna cable to scanner RF input. If you are measuring with two
downconverters, connect an antenna in both RF inputs (see picture below).
NEMO SCANNER G UIDE 5
2. Connect Ethernet cable(s) to the scanner Ethernet port(s) and to the Nemo Outdoor laptop.
3. Go to Control Panel | Network and Internet | Network and Sharing Center. Click on
Change adapter settings.
4. Right-click on Local Area Connection and select Properties. In the Local Area Connection
Properties dialog, select Internet Protocol Version 4 (TCP/IPv4) and click Properties.
NEMO SCANNER G UIDE 6
5. Select Use the following IP address and type in the IP address of the scanner in the IP
address field. Click OK and Close.
Please note that by default the Nemo FSR1 is delivered with a fixed IP address. The IP
address can be changed with a separate utility software. The following IP addresses are
used in Nemo Outdoor:
"Nemo Scanner LAN" = 192.168.3.253
"Nemo Scanner LAN 2" = 192.168.3.252
"Nemo Scanner LAN 3" = 192.168.3.251
"Nemo Scanner LAN 4" = 192.168.3.250
6. Connect the power cable to the scanner and to a power source. Switch power on.
Fuse
Power connector Power switch
Fans
NEMO SCANNER G UIDE 7
7. The default address and name settings of the scanner are generally suitable for most users.
There is no need to configure these settings when using the Nemo FSR1 scanner with Nemo
Outdoor.
8. The status LEDs at the front panel display how the scanner is functioning.
LED Name LED Color Description RxA Green Receiver A enabled
Amber Receiver A disabled i.e. EEPROM not readable RxB Green Receiver B enabled
Amber Receiver B disabled i.e. EEPROM not readable Status Green GPS Locked
Amber GPS Unlocked Active Green Ethernet link connected
Red Ethernet link disconnected All LEDs Amber If all four LEDs are amber, the bootloader is
running and the module needs to be reloaded
NEMO SCANNER G UIDE 8
CONNECTING ANRITSU SCANNERS
These instructions apply to all Anritsu scanners, except Anritsu MS2721B DVB-H
Analyzer.
1. Connect the antenna cable to scanner RF Input. If you are measuring with a dual-mode
scanner that supports both GSM and WCDMA, use the RF1 input (see picture). RF2 input
only supports WCDMA scanning.
2. Connect the battery cable to the battery and to a power source.
3. The Battery led of the scanner should turn green.
The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are
measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12.
NEMO SCANNER G UIDE 9
4. Connect the null modem cable to the scanner COM port that can be found below the power
switch.
5. Connect the null modem to one of the PC COM ports
6. Turn the power on in the scanner. The Power led should light up.
7. The scanner should now start, wait until the scanner has started
8. Press the Menu button in the scanner.
9. Use the arrow keys and the Sel button to select Interface and Behavior.
10. Check that the settings are as follows. If not, change them using the arrow keys and the Sel
button (note that the selected item will be underlined as soon as you use the arrow buttons
to switch to another line). To exit the dialog without saving, press the F4 button (Cancel). To
exit the dialog and save the modified settings, press the F5 button (OK).
COM1 Protocol: Direct
COM1 Baud Rate: 38400 or 57600 or 115200
COM1 Stop Bit(s): 1
COM1 Data Length: 8
COM1 Parity: None
The baud rate 115200 is the fastest option.
Note! Memorize the baud rate. It is needed when starting the device.
11. If you are measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see the
following steps.
NEMO SCANNER G UIDE 10
12. Insert the Anritsu installation CD in your PC.
13. Connect the USB cable to the scanner USB port found in the front panel and to the PC.
14. Switch the scanner on.
15. The New Hardware Wizard will start automatically. Select the No, not this time option and
click Next.
16. Select the Install the software automatically option and click Next.
NEMO SCANNER G UIDE 11
17. If a warning message appears, click Continue Anyway. The installation will start. Please
wait while the New Hardware Wizard installs the software. When the installation is complete,
click Finish.
18. To check that the installation was successful, go to Device Manager (Start | Settings |
Control Panel | System | Hardware | Device Manager). Expand the Universal Serial Bus
controllers item. Area Scanner should be on the list.
NEMO SCANNER G UIDE 12
19. Double-click on Area Scanner. Check that the Device Status field displays This device is
working properly. Exit the dialog by clicking OK.
Connecting the Anritsu MS2721B DVB-H Analyzer/Anritsu MS2721B Spectrum Analyzer Scanner
Installing the driver:
Please follow the following steps to install the NI-VISA 4.0 driver.
1. To install the driver the user must have administrative rights to its PC, and the Take
ownership of files or other objects policy has to be enabled for this user on this PC.
2. Copy the executable file visa400full.exe to your local drive before installing the driver, and
run the installation from the hard drive.
NEMO SCANNER G UIDE 13
3. Double-click on the file and unzip the contents to your hard-drive. This may take a couple of
minutes.
4. The installation starts automatically.
5. Click Next>> on the welcome page.
NEMO SCANNER G UIDE 14
6. Select the destination folder for the driver and click Next>>.
7. Click Next>> in the Features dialog.
8. Select I accept the License Agreement(s) in the following page and click Next>>.
9. Click Next>> in the following dialog and wait for the installation to finish, and Finish in the
Installation Complete dialog. Note that you may need to restart your computer for the
installation to take effect.
NEMO SCANNER G UIDE 15
10.Connect the scanner with your PC through a network cable. Insert one end of the network
cable in the network cable connector in the scanner, and the other end to the network cable
connector in your PC.
11.Next, you need to make some changes to your PC’s network card properties. Go to Start |
Control Panel | Network Connections, and right-click on Local Area Connection, and
select Properties. In the Local Area Connection Properties dialog, select Internet Protocol
(TCP/IP) and click on Properties. Select Use the following IP address. You need to type in
an IP address out of the range 192.168.0.11 - 192.168.0.14, as those addresses are
reserved for the scanner. Type in, for example, 192.168.0.10. Next, type 255.255.0.0 in the
Subnet mask field. Click OK and Close to exit the dialogs.
12. Next, start the scanner by pressing on the green On/Off button.
13. Press on Shift and then System (8) button on the scanner.
14. On the menu to the right of the screen, select System Options | Ethernet Config by using
the grey buttons next to the screen.
NEMO SCANNER G UIDE 16
15. Select the Set the IP Address Manually using the following Settings by pressing the top-
most grey button immediately under the Esc button.
16. Type in the same IP address for both IP and Gateway from those reserved for the scanner
(192.168.0.11 - 192.168.0.14). Here the selected IP address will be 192.168.0.14. You can
move to different directions on the screen through the grey buttons. If the Subnet field is not
automatically filled when filling the IP and Gateway fields, you can use, for example,
255.255.255.255 for it. Press Enter and restart the device by clicking twice on the On/Off
button.
17. When the scanner has restarted, start Nemo Outdoor. Go to Measurement | Add device |
Scanner, and select Anritsu MS2721B DVB-H or Anritsu MS2721B Spectrum Analyzer. Click
Next.
18.In the Scanner Properties dialog that appears, select one of Anritsu LAN 1-4 ports
depending on which IP address you entered on the device. If you entered 192.168.0.11,
select Anritsu LAN 1, if you selected 192.168.0.12, select Anritsu LAN 2, etc. Since
192.168.0.14 was selected earlier, the Anritsu LAN 4 port will be used here.
Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so
they can be left as they are.
19. Click OK. See page 77 for more information on how to perform DVB-H measurements. See
page 77 for instructions regarding settings for the Spectrum Analyzer.
NEMO SCANNER G UIDE 17
CONNECTING THE DRT WIMAX 4301A+ SCANNER
Note! The DRT 4301A+ scanner does NOT have an On/OFF switch. The unit is powered by
connecting the power cable and powered off by disconnecting the power cable. When
connecting cables to the unit, the power cable should be the last one connected and the
first one disconnected.
1. Insert one end of the RJ-45 cable in the DATA jack in the scanner, and connect the other
end with the PC.
2. Insert the power cable in the connector marked DC IN.
3. Plug the antenna cable in the FR IN B port in your DRT scanner.
Note that you can only select one of the antennas, 2300/2500MHz or the 3500MHz
antenna, and connect it with the scanner. You must select between the antennas at this
point.
4. Connect the scanner’s GPS antenna cable to the scanner’s GPS port, and place the GPS
antenna on a visible spot.
5. Go to Start | Control Panel | Network Connections on your PC.
6. Right-click on Local Area Connection and select Properties.
7. In the Local Area Connection Properties dialog, select Internet Protocol (TCP/IP) |
Properties.
NEMO SCANNER G UIDE 18
8. In the General tab, select Use the following IP address, and type 192.168.5.1 in the IP
address field, and 255.255.255.0 in the Subnet mask field.
9. Click OK and Close to exit the dialogs.
10. Now connect the scanner’s power cable. The scanner is now on. A green light will turn on in
the scanner.
11. Start Nemo Outdoor. Go to Measurement | Add New Device | Scanner. Select DRT
WIMAX 2300, DRT WIMAX 2500 or DRT WIMAX 3500 depending on which band you
choose to measure at the time.
NEMO SCANNER G UIDE 19
12. In the Scanner Properties dialog, select DRT LAN in the Port drop-down menu.
Note that the Baud rate, Antenna gain and Cable loss fields do not affect the scanner, so
they can be left as they are.
13. Click OK to exit the dialog.
14. Go to page 102 for more information on conducting WIMAX measurements with the DRT
scanner.
NEMO SCANNER G UIDE 20
CONNECTING THE PCTEL LX CDMA/EVDO/GSM/WCDMA SCANNER
1. Connect the antenna cable to the scanner RF Input.
2. Connect the scanner GPS antenna cable to the scanner GPS input (above RF Input).
NEMO SCANNER G UIDE 21
3. Connect the scanner power cable to the scanner serial port (Data).
4. The scanner cable is split into a serial cable connector and a power cable connector.
Connect the serial cable to one of the COM ports in the PC. Connect the scanner power
cable to a cigarette lighter in the car.
5. When connecting the scanner power cable, check the Power led:
If the led is first orange for a while and then turns green, the scanner is working properly
and using a baud rate of 38400
If the led blinks orange and black for a while and then turns green, the scanner is
working properly and using baud rate of 115200
If the led is red, the scanner is not working properly. Switch the power off and on again.
If this occurs after usage, the device may be overheated. Let it cool down for a while.
Note! Memorize the baud rate. It is needed when starting the device.
Connecting External GPS to PCTEL LX EVDO/GSM/WCDMA Scanner
Note that you cannot use both the integrated and an external GPS receiver at the same
time.
1. Connect the GPS serial cable to a PC serial port.
If there is only one port in the PC by default, this port should be reserved for the scanner.
In this case connect the GPS to the PCMCIA serial port adapter.
2. Connect the GPS power cable to a cigarette lighter.
NEMO SCANNER G UIDE 22
CONNECTING PCTEL EX SCANNERS
Installing the SeeGull EX VCP Device Driver
Please follow the following steps to install the VCP device driver.
1. To install the driver the user must have administrative rights to its PC, and the Take
ownership of files or other objects policy has to be enabled for this user on this PC.
2. Copy the folder /SeeGull EX VCP driver_v.2.0.0.46B to your local drive before installing the
driver, and run the installation from the hard drive.
Right click on the folder and select Properties.
Clear the Read-only attributes and click OK.
Select Apply changes to this folder, subfolder and files as below
and click OK.
3. Double-click on the SeeGull EX VCP Device Driver.msi installer file to start the driver
installation.
4. Click Next in the SeeGull Welcome window that appears.
5. Select the destination folder for the driver in the Destination Folder window, and Click Next,
and click Install.
NEMO SCANNER G UIDE 23
6. Click Finish in the InstallationShield Wizard Completed window to exit the wizard.
7. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front
panel.
NEMO SCANNER G UIDE 24
8. Connect the power cable to the Power connector in the front panel. Connect the other end of
the cable to a cigarette lighter socket. The SYS indicator in the front panel will light up.
9. Connect the antenna cables. It does not matter which antenna cable goes to which RF
connector.
NEMO SCANNER G UIDE 25
10. Connect the GPS antenna to the connector marked GPS.
11. Connect the USB data cable to the USB port in the front panel. Connect the other end of the
USB data cable to your PC.
12. Windows will automatically detect the device.
NEMO SCANNER G UIDE 26
CONNECTING THE PCTEL LX GSM/WCDMA DUAL-MODE SCANNER
1. Remove the yellow plastic caps from the antenna and GPS connectors in the front panel.
2. Connect the power cable to the Power and Data connector in the front panel. Connect the
other end to a USB port on your computer and to a power source. The green Power indicator
in the scanner front panel will light up.
NEMO SCANNER G UIDE 27
3. Connect the antenna cables. Note that the antenna cables and the connectors in the
scanner front panel are color coded. The OP042 cable marked with yellow is connected to
the RF1 connector marked with yellow (connector on the left). The OP039 cable marked with
blue is connected to the RF2 connector marked with purple (connector in the middle).
4. Connect the GPS antenna to the connector marked GPS (connector on the right).
5. Windows will have detected the new device and will install the required drivers. Insert the
PCTEL installation CD.
6. Select No, not this time in the Welcome dialog.
NEMO SCANNER G UIDE 28
7. Select Install from a list of specific location and click Next.
8. Select Include this option in the search and browse to folder D:\EdgeportUSB\Edgeport
Vendor Data\driver vx.x. Click Next to start the installation.
9. When the installation is finished, click Finish. Windows will automatically install some
additional drivers and report when the device is ready to be used.
NEMO SCANNER G UIDE 29
CONNECTING THE PCTEL MX GSM/WCDMA SCANNER
Installing the SeeGull MX Device Driver
Please follow the following steps to install the device driver.
1. To install the driver the user must have administrative rights to its PC, and the Take
ownership of files or other objects policy has to be enabled for this user on this PC.
2. Browse to folder seegull mx driver\MX winusb driver. For 32-bit operating system run
DPInst.exe from “install x86” folder and for 64-bit operating system run DPInst.exe from
“install x64” folder.
3. The PCTEL USB Device Installer window will appear. Click Next.
4. If a Windows Security message appears, click Install.
5. Click Finish in the installation completed window.
6. Remove the yellow plastic caps from the antenna, power and GPS connectors in the front
panel.
NEMO SCANNER G UIDE 30
7. Connect the power cable to the PWR connector in the front panel. Connect the other end of
the cable to a cigarette lighter socket. The Status indicator in the front panel will light up.
8. Connect the antenna cables. The label on the scanner lists the frequencies of the radio
modules connected to each specific port, labeled RF1 to RF8. The antenna ports that require
antenna connections are identified by their “frequency” on the label. Since each SeeGull MX
is configured to minimize the number of ports necessary for use, some ports may be inactive
for a particular configuration and are indicated by a blank box.
NEMO SCANNER G UIDE 31
9. Connect the GPS antenna to the connector marked GPS.
10. Connect the USB data cable to the USB port in the front panel. Connect the other end of the
USB data cable to your PC.
11. Windows Vista and Windows 7 will automatically detect and install the device.
12. With Windows XP a Found new Hardware window will appear. Select No, not this time in
the Welcome window. Select Install the software automatically (Recommended) and click
Next. Finally click Finish.
13. Go to Start | Control Panel | System | Hardware | Device Manager and select Ports.
Memorize the port number for the PCTEL Communications Port item, as you will need it later
on.
NEMO SCANNER G UIDE 32
CONNECTING PCTEL PCT SCANNERS
Installing PL2303 Prolific DriverInstaller Driver
1. Run the PL2303_Prolific_DriverInstaller_vx.x.exe (x refers to the version number) file on the
installation CD.
2. Click Next in the Welcome window that appears.
3. Click Finish to finish the driver installation.
4. Next, remove the yellow plastic caps from the antenna and GPS connectors in the front
panel of the PCTEL PCT scanner.
5. Connect the antenna cable in the RF Input connector.
NEMO SCANNER G UIDE 33
6. Connect the data cable to the Data connector. Connect the other end of the USB data cable
to your PC.
7. Connect the power cable to the Power connector in the front panel. Connect the other end of
the cable to a cigarette lighter socket.
8. Windows automatically detects the new hardware.
NEMO SCANNER G UIDE 34
9. Go to Start | Control Panel | System | Hardware | Device Manager and select Ports.
Memorize the port number for the Prolific USB-to-Serial Comm Port item, as you will need
it later on.
NEMO SCANNER G UIDE 35
CONNECTING THE ROHDE & SCHWARZ TSMQ/TSML SCANNER
Note that your PC must have a FireWire (IEEE1394) port in it and a 32-bit PC FireWire
controller card for you to be able to connect a Rohde & Schwarz TSMQ Scanner
Driver installation:
1. First, install the TSMxDriverInstall.exe file on the installation CD.
2. Click Run to run the installation file.
3. Click Next in the Welcome window that appears.
NEMO SCANNER G UIDE 36
4. Next, connect the antenna cable to the RF Input connector in the Rohde & Schwarz scanner.
5. Connect the FireWire cable to one of the IEEE ports and the other end to your PC or a
FireWire adapter in the PC.
NEMO SCANNER G UIDE 37
6. Next, connect the power cable to the DC IN connector and the other end to a power source.
7. Windows automatically detects the new hardware. Select No, not this time and click Next in
the Welcome window that appears.
NEMO SCANNER G UIDE 38
8. Select Install the software automatically (Recommended), and click Next.
9. Click Finish to finish the installation.
10. Go to Device Manager from Start | Control Panel | System | Hardware | Device Manager.
You should see the Rohde & Schwarz TSMx Devices item, and the applicable Rohde &
Schwarz scanner model under it.
NEMO SCANNER G UIDE 39
CONNECTING THE ROHDE & SCHWARZ TSMW SCANNER
1. First, connect antenna cables to the RF1 and RF2 input connectors. See chapter System
Priority Order with R&S TSMW Scanners on page 41 for information on connecting the
antennas to the correct ports.
NEMO SCANNER G UIDE 40
2. Next, connect the network cable connector to the LAN connector in the scanner.
Note that the network port in the computer to which the cable is connected should be at
least 1 Gbps.
3. Connect the power cable to the DC IN port in the scanner, and the other end of the cable to
a power source.Connect the power cable either to a Mascot power supply, or with the
applicable cigarette lighter adapter, to a cigarette lighter socket.
NEMO SCANNER G UIDE 41
4. Next, you need to make some changes to your PC’s network card properties. Go to Start |
Control Panel | Network Connections, and right-click on Local Area Connection, and
select Properties. In the Local Area Connection Properties dialog, select Internet Protocol
(TCP/IP) and click on Properties. Select Use the following IP address. You need to type in
an IP address within the range of 192.168.0.1 - 192.168.0.255. The default IP address for
the scanner is 192.168.0.2, so it should be avoided. Next, type 255.255.255.0 in the Subnet
mask field. Click OK and Close to exit the dialogs.
5. In Windows 7, go to Start | Control Panel | Network and Internet | Network and Sharing
Center. Select Local Area Connection in the View your active networks list. In the Local
Area Connection Status dialog, select Properties. In the Local Area Connection Properties
dialog that opens, select the Networking tab, and Internet Protocol Version 4 (TCP/IPv4)
in the This connection uses the following items view. Click on Properties. Select Use the
following IP address. You need to type in an IP address within the range of 192.168.0.1 -
192.168.0.255. The default IP address for the scanner is 192.168.0.2, so it should be
avoided. Next, type 255.255.255.0 in the Subnet mask field. Click OK and Close to exit the
dialogs.
6. The device is now connected to the computer. See Starting Devices below for information on
how to connect the scanner with Nemo Outdoor.
System Priority Order with R&S TSMW Scanners
Multiple cellular technologies (systems) are measured in a parallel manner. The different
systems are arranged in a priority order as shown in Figure 4. The CDMA and EVDO systems
are counted as one system. Nemo Outdoor handles priority and allocates the RF ports
automatically. In this case priority refers to the order in which systems are allocated to RF port
#1 and RF port #2. The resource slot number defines in how many processes one RF port is
divided.
Both ports, RF #1 and RF #2, have 100% of available resources. When only one system
(except LTE) is measured, for example WCDMA, it is set to be measured via RF port #1 with
100% of its resources. When two systems are measured simultaneously, for example GSM and
WCDMA, GSM has higher priority over WCDMA. GSM is set to be measured via RF port #1
with 100% of its resources, whereas WCDMA system is set to be measured via RF port #2 with
100% of its resources.
NEMO SCANNER G UIDE 42
When three systems are measured simultaneously, for example GSM, WCDMA and CDMA, the
systems are again allocated in the priority order for the two RF ports. In this case RF port #1 is
shared by two systems: GSM and CDMA. Each system gets 50% of the RF port #1 resources.
100% of RF port #2 resources are allocated to WCDMA measurements.
With LTE, individual carriers are allocated to the two RF ports. For example, when measuring
two or more LTE carriers, carriers are arranged in order from lowest frequency number to the
highest. After that, carriers (frequencies) are allocated to the RF ports so that the first carrier is
allocated to RF port #1 and the second carrier to RF port #2, third carrier is again allocated to
RF port #1 and the fourth carrier to RF port #2, etc.
If the measurement setup includes an odd number of other systems in addition to LTE, the first
LTE carrier is allocated to RF port #2. The second LTE carrier is allocated to RF port #1, etc.
However, if the measurement setup includes only one other system in addition to LTE, the other
system is allocated to RF port #1 and all LTE carriers are allocated to RF port #2.
Spectrum scanning is counted as one of the systems. Spectrum scanning always has the
highest priority and it is set to be measured via RF port #1. The resource slot number defines in
how many processes one RF port is divided.
NEMO SCANNER G UIDE 43
STARTING DEVICES
Starting Nemo Outdoor:
1. Start Nemo Outdoor from the Start menu, Nemo Tools submenu.
2. Do not load any previous device configuration if asked.
STARTING NEMO FSR1 SCANNER
1. From the Measurement menu, select Add New Device.
2. Click on Scanner.
3. From the list select Nemo FSR1 and click Next.
4. In the Scanner Properties dialog, select Nemo Scanner LAN as the Port and click OK.
NEMO SCANNER G UIDE 44
5. If the dialog did not close, the startup did not succeed. Check the cable connections and the
settings and try again.
6. If the Device Status window is not visible, open it from the View menu. A green light should
be blinking. This means that the device is working properly and scanning using the default
settings. If the status field displays, Device is not started, check that you are in online mode
(click the Work Offline/Online button ). If the device is started but not scanning, check
that you have selected channels to be scanned.
NEMO SCANNER G UIDE 45
STARTING ANRITSU SCANNERS
1. From the Measurement menu, select Add New Device.
2. Click on Scanner.
3. From the list select:
For Anritsu ML8720B: Anritsu ML8720B UMTS 2100 and click Next.
For Anritsu ML8720C without the GSM option: Anritsu ML8720C UMTS 2100 and click
Next.
For Anritsu ML8720C with the GSM option: Anritsu ML8720C GSM/UMTS and click
Next.
For Anritsu ML8740A and Anritsu ML8740B without the GSM option: Anritsu ML8740A/
ML8740B UMTS 2100 and click Next.
For Anritsu ML8740A and Anritsu ML8740B with the GSM option: Anritsu
ML8740A/ML8740B GSM/UMTS and click Next.
For Anritsu MS2721B DVB-H Analyzer: Anritsu MS2721B DVB-H, and click Next.
For Anritsu MS2721B Spectrum Analyzer: Anritsu MS2721B Spectrum Analyzer, and
click Next.
4. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to
(ML8720B/ML8720C)/select the USB port (e.g., Anritsu USB1)/or select the Anritsu LAN 1-4
with Anritsu MS2721B DVB-H depending on which IP address was selected for the scanner.
The next step is not valid for the Anritsu ML8740A, Anritsu ML8740B, Anritsu MS2721B
DVB-H, or Anritsu MS2721B Spectrum Analyzer scanner.
NEMO SCANNER G UIDE 46
5. Set the baud rate to the one used by the scanner and click OK. Note that the baud rate
must be the same that you chose when you were connecting the scanner. The dialog
will be closed and the scanner should now be connected to the system.
6. If the dialog did not close, the startup did not succeed. Check the cable connections and the
settings and try again.
7. If the Device Status window is not visible, open it from the View menu. A green light should
be blinking. This means that the device is working properly and scanning using the default
settings. If the status field displays, Device is not started, check that you are in online mode
(click the Work Offline/Online button ).
NEMO SCANNER G UIDE 47
STARTING DRT SCANNERS
1. From the Measurement menu, select Add New Device.
2. Click on Scanner.
3. From the list select:
DRT WIMAX 2300, if you want to make measurements with the 2300 MHz
(WiMAX) band.
DRT WIMAX 2500, if you want to make measurements with the 2500MHz
(WiMAX) band.
DRT WIMAX 3500, if you want to make measurements with the 3500MHz
(WiMAX) band.
NEMO SCANNER G UIDE 48
4. In the Scanner Properties dialog, set the COM Port to DRT LAN.
Note that the no changes need to be made to the Baud rate, Antenna gain, and Cable loss
fields. See the next chapter for further instructions on how to make measurements.
NEMO SCANNER G UIDE 49
STARTING PCTEL SCANNERS
Starting the GPS:
With the PCTEL LX WCDMA scanner you can use either the GSP receiver integrated into the
scanner or an external GPS. See page 51 for instructions on how to enable the integrated GPS
receiver.
Note that you cannot use both the integrated and an external GPS receiver at the same
time.
Note that with the PCTEL LX GSM/WCDMA scanner the Internal GPS receiver should be
activated only in UMTS mode.
To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix
at least 30 seconds before starting the Nemo Outdoor application in online mode. If the
existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the
configuration file in offline mode. If scanner does not send any results after 30 seconds,
it is advised to send a reset command to the scanner via the user interface.
1. From the Measurement menu, select Add New Device.
2. Click on GPS.
3. From the list, select the GPS model that you have connected to the PC and click Next.
4. The GPS Properties dialog is opened. Set the parameters (see the GPS User Manual for
instructions). They should be correct by default. Click OK. The view will return to the Nemo
Outdoor main window.
5. In the Device Status window a green light should be blinking. This means that the GPS is
working properly.
Starting the PCTEL LX/EX/PCT GSM/WCDMA/1xEV-DO/LTE Scanner:
1. From the Measurement menu, select Add New Device.
2. Click on Scanner.
3. From the list select:
For PCTEL LX UMTS 1700/2100 scanner: PCTEL LX UMTS 1700/2100, and click
Next.
For PCTEL LX UMTS 1900 scanner: PCTEL LX UMTS 1900, and click Next.
For PCTEL LX UMTS 2100 scanner: PCTEL LX UMTS 2100, and click Next.
For PCTEL LX UMTS 850/1900 scanner: PCTEL LX UMTS 850/1900, and click Next..
For PCTEL LX UMTS 850 scanner: PCTEL LX UMTS 850, and click Next..
For PCTEL LX CDMA/EV-DO 850 scanner, select PCTEL LX EVDO 800, and click
Next.
For PCTEL EX WCDMA 2100 AWS&GSM 850/ 1900 scanner: PCTEL EX GSM
850/1900 UMTS AWS, and click Next.
For PCTEL LX 1xEV-DO 450 scanner: PCTEL LX EVDO 450, and click Next.
NEMO SCANNER G UIDE 50
For PCTEL LX 1xEV-DO 850 scanner: PCTEL LX EVDO 800, and click Next.
For PCTEL LX 1xEV-DO 1900: PCTEL LX EDVO 1900, and click Next.
For PCTEL EX CDMA/EV-DO 850/1900 scanner, select CDMA2000 850/1900 EVDO
850/1900, and click Next.
For PCTEL EX GSM 850/1900 & WCDMA 850/1900 scanner: PCTEL EX GSM
850/1900 UMTS 850/1900, and click Next.
For PCTEL EX GSM 900/1800 & WCDMA 900/2100 scanner: PCTEL EX GSM
900/1800 UMTS 900/2100, and click Next.
For PCTEL PCTEL EX GSM 1900 & WCDMA 2100 AWS scanner: PCTEL EX GSM
1900 UMTS AWS, and click Next..
For PCTEL EX WIMAX scanner: PCTEL EX WIMAX, and click Next.
For PCTEL EX 900/1800 WCDMA/TD-SCDMA 2000, select PCTEL EX 900/1800
UMTS TDSCDMA 2000, and click Next.
For PCTEL EX LTE 1800/2600 scanner, select PCTEL EX LTE 1800/2600, and click
Next.
For PCTEL EX LTE 2100 scanner, select PCTEL EX LTE 2100, and click Next.
For PCTEL EX LTE 2100/2600 scanner, select PCTEL EX LTE 2100/2600, and click
Next.
For PCTEL EX LTE 700ABC scanner, select PCTEL EX LTE 700ABC, and click Next.
For PCTEL EX LTE 700C scanner, select PCTEL EX LTE 700C, and click Next.
For PCTEL EX LTE AWS/700BC scanner, select PCTEL EX LTE AWS/700BC, and
click Next.
For PCTEL EX LTE AWS/700C scanner, select PCTEL EX LTE AWS/700C, and click
Next.
PCTEL EX mini series scanners:
o For WCDMA 2100, select PCTEL EX UMTS 2100, and click Next...
o For WCDMA 850/1900, select PCTEL EX UMTS 850/1900, and click Next...
o For WCDMA 900/2100, select PCTEL EX UMTS 900/2100, and click Next...
o For WCDMA AWS, select PCTEL EX UMTS AWS, and click Next...
For PCTEL MX scanners, select PCTEL MX and click Next.
For PCTEL PCT GSM 900/1800 scanner, select PCTEL PCT GSM 900/1800, and click
Next.
For PCTEL PCT UMTS 2100 scanner, select PCTEL PCT UMTS 2100, and click Next.
NEMO SCANNER G UIDE 51
4. In the Scanner Properties dialog, set the COM Port to the port the scanner is connected to.
With MX scanners, select the PCTEL USB item.
5. Set the baud rate to the one used by the scanner and click OK. The dialog will be closed and
the scanner should now be connected to the system.
6. If the dialog did not close, the start-up did not succeed. Check the cable connections and the
settings and try again.
7. From the View menu activate Device Status. A check mark will appear next to the
command when it is activated.
8. A green light on the PCTEL scanner in the Device Status window should be blinking. This
means that the device is working properly and scanning using the default settings. See
chapter Starting Measurement (page 56) for instructions on making your own scanner
configuration.
Enabling integrated GPS receiver for PCTEL LX WCDMA/PCTEL EX WiMAX scanner
1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog click the Advanced button.
NEMO SCANNER G UIDE 52
3. In the Advanced Properties dialog, select Yes for the Enable Integrated GPS Receiver
option and click OK.
4. The integrated GPS receiver is now enabled.
Note that you cannot use both the integrated and an external GPS receiver at the same
time.
Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be
activated only with UMTS mode.
To be able to make Top-N preamble scanning the scanner receiver must acquire a GPS fix
at least 30 seconds before starting the Nemo Outdoor application in online mode. If the
existing configuration file includes a PCTEL WiMAX scanner, it is advised to open the
configuration file in offline mode. If scanner does not send any results after 30 seconds,
it is advised to send a reset command to the scanner via the user interface.
NEMO SCANNER G UIDE 53
Starting the PCTEL LX GSM/WCDMA dual-mode scanner
1. From the Measurement menu, select Add New Device. Click on Scanner.
2. From the list select PCTEL LX GSM 900/1800 and click Next.
3. In the Scanner Properties dialog, Port field you should see two consecutive COM ports
(e.g., COM 3 and COM 4). Select the COM port with the smaller number and click OK.
4. From the Measurement menu, select Add New Device. Click on Scanner.
5. From the list select PCTEL LX UMTS 2100 and click Next.
6. In the Scanner Properties dialog, Port field you should see two consecutive COM ports
(e.g., COM 3 and COM 4). Select the COM port with the bigger number and click OK.
7. A green light should be blinking in the Device Status for both devices. This means that the
devices are working properly and scanning using the default settings. If the status field
displays, Device is not started, check that you are in online mode (click the Work
Offline/Online button ).
8. The GSM and UMTS scanners will appear as separate devices and must be configured
individually.
Enabling integrated GPS receiver for PCTEL LX GSM/WCDMA dual-mode scanner
Note that with the PCTEL dual-mode scanner the integrated GPS receiver needs to be
enabled only for one scanner.
1. After the PCTEL LX scanners are connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
NEMO SCANNER G UIDE 54
2. In the Measurement Properties dialog click the Advanced button.
3. In the Advanced Properties dialog, select Yes in the Enable Integrated GPS Receiver
option and click OK.
4. The integrated GPS receiver is now enabled.
Note that you cannot use both the integrated and an external GPS receiver at the same
time.
Note that with the PCTEL LX GSM /WCDMA scanner the Internal GPS receiver should be
activated only with UMTS mode.
NEMO SCANNER G UIDE 55
STARTING ROHDE & SCHWARZ SCANNERS
1. Start Nemo Outdoor. From the Measurement menu, select Add New Device.
2. Click on Scanner.
3. From the list select the applicable R&S scanner, and click Next..
4. In the Scanner Properties dialog, select R&S IEEE1394A in the Port drop-down menu.
Click OK.
5. A green light should be blinking in the Device Status for both devices. This means that the
devices are working properly and scanning using the default settings. If the status field
displays, Device is not started, check that you are in online mode (click the Work
Offline/Online button ).
NEMO SCANNER G UIDE 56
STARTING MEASUREMENT
NEMO FSR1 SCANNER
Frequency Scanning
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog you can select the channels to be scanned.
3. On the Frequency scanning, GSM page, click the Select Channels button to select the
GSM channels to be scanned.
Channel style defines the style of the measured channel. For GSM the option is 200 kHz.
Data mode defines the type of measurement data computed from each sample. Note that the
available selection depends on the scanner type.
RX Level Average: the data reported is the average RX level, in dB, of the number of
samples.
Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
NEMO SCANNER G UIDE 57
Sample size defines the number of samples taken from each channel before a measurement
result is written to file.
Selecting the BSIC decoding option displays BSIC value in a measurement window.
BSIC threshold defines the minimum BSIC level that the scanner reports.
Select the BCCH C/I option to activate C/I measurements for the BCCH channel.
4. Click the Start Recording button to start recording the results in an output file.
TOP-N Pilot Scanning - UMTS
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N pilot mode/scanning.
To set pilot scanning settings:
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.
CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are
below the threshold, the pilots are not reported.
NEMO SCANNER G UIDE 58
Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow
Band (200kHz) and Wide Band (3.84MHz).
Correlator affects how the scanner works. Bigger correlator size enables the scanner to detect
and measure pilot channels with better dynamic but makes scanning speed slower. For
example, when using correlator size 2048 versus 512, the dynamic range for pilot measurement
changes from –21db to –17db.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
Pilot measurement mode defines the measurement mode for pilot scanning.
In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,
weak pilots may be undetected.
In High dynamic mode scanning speed is lower but sensitivity is higher.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode. The maximum number is 32.
Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID
information can be decoded from BCCH messages. Note that this is only enabled in online
mode and if the option has been purchased with the scanner. Cell information decoding is
supported only in WCDMA.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
NEMO SCANNER G UIDE 59
To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N
Configuration button. The Select Channels dialog is opened.
2. The table displays the channel numbers, not the frequencies.
3. You can remove channels from the Selected list by selecting a channel and clicking the
Remove button.
4. You can add channels to the Selected list by selecting a channel from the Available list
and clicking the Add button.
5. Click OK to return to the Measurement Properties dialog.
6. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
7. A green light on the scanner Device Status window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
8. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 60
TOP-N Pilot Scanning - CDMA/EVDO
Note that the EVDO measurements can only be performed in a proper way when a
CDMA2000 channel is measured as well. In this way, the time relationship between the
different PN offsets is resolved.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning, CDMA page.
Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the
threshold, the pilots are not scanned.
Top-N mode option enables/disables TOP-N scrambling code scanning. Number of pilots field
defines how many pilots are reported by the scanner in TOP-N mode.
Overhead message decoding, when selected, enables the scanner to decode PCH
messages.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
Note that the Nemo FSR1 scanner supports max 32 channels.
NEMO SCANNER G UIDE 61
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button to start recording the results in an output file.
TOP-N Pilot Scanning – LTE
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.
Sync signal refers to the ratio between the synchronization channel, i.e., primary and
secondary signal received power and the interference and noise from the same synchronization
signal set.
Reference signal refers to the ratio between the reference signal received power (RSRP) and
the interference and noise from the same reference signal set.
NEMO SCANNER G UIDE 62
The Select Channels button will open the Select Channels dialog where you can select
channels for pilot scanning.
When you select LTE channels, you can also define some channel-specific settings. In the LTE
Channel Specific Settings dialog, select the channel from the Selected channels list and
define the settings.
Note that the available options are device specific.
Uplink-downlink configuration refers to LTE TDD frame structure.
Frame structure type 2 is applicable to TDD. Each radio frame of length ms 10307200 sf TT
consists of two half-frames of length ms 5153600 s T each. Each half-frame consists of five
subframes of length ms 107203 s T . The supported uplink-downlink configurations are listed in
the table below where, for each subframe in a radio frame, “D” denotes the subframe is
reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink
transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One slot, Tslot=15360 Ts
GPUpPTS
DwPTS
One radio frame , Tf = 307200Ts = 10 ms
One half -frame, 153600 Ts = 5 ms
30720Ts
One subframe , 30720 Ts
GP UpPTS
D wPTS
Subframe #2 Subframe #3 Subframe #4Subframe #0 Subframe #5 Subframe #7 Subframe #8 Subframe #9
NEMO SCANNER G UIDE 63
Frame structure type 2 (for 5 ms switch-point periodicity):
Uplink-downlink configuration
Downlink-to-Uplink Switch-point periodicity
Subframe number 0 1 2 3 4 5 6 7 8 9
0 5 ms D S U U U D S U U U 1 5 ms D S U U D D S U U D 2 5 ms D S U D D D S U D D 3 10 ms D S U U U D D D D D 4 10 ms D S U U D D D D D D 5 10 ms D S U D D D D D D D 6 5 ms D S U U U D S U U D
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 64
Spectrum Analyzer Measurements
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page. Select the
Enable spectrum scanning option and click on Add.
NEMO SCANNER G UIDE 65
3. Define the start and stop frequencies within which the measurement will be performed. If
you manually define the start and stop frequencies, you can either select to add the
frequencies to the scanning list or save them as a predefined set. Select your option in the
Add to scanning list menu.
4. Select Set center frequency and bandwidth to define the center frequency and the
bandwidth to be measured. If you manually define the center frequency and bandwidth, you
can either select to add them to the scanning list, or save them as a predefined set. Select
your option in the Add to scanning list menu.
It should be noted that resolution bandwidths with FSR1 scanner devices are fixed.
Currently supported values are: 1875, 3750, 7500, 15000, 30000, 60000 and 120000 kHz.
5. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in
the Measurement Properties dialog can increase the scanner’s measuring sensitivity,
hence slightly decreasing background noise. However, it is recommended that it is not
selected when signal volume is higher than -50dBm.
NEMO SCANNER G UIDE 66
6. You can add scanning sets in the Predefined scanning sets field through the Add to
Scanning List button. Click the arrow in the button and select Save as Predefined Set.
Define a name in the Enter Frequency Set Name field and click OK.
7. The name appears in the Predefined scanning sets field along with the chosen frequency
and/or bandwidth information selected in the Reporting field.
8. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
9. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
10. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 67
ANRITSU SCANNERS
Frequency Scanning
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog you can select the channels to be scanned:
If the scanner supports only one carrier, you can select either GSM or UMTS channels to
be scanned.
If the scanner supports two carriers, you can select for scanning both GSM and UMTS
channels. If you select GSM channels, you can select a maximum of one UMTS
channel. If you do not select GSM channels, you can select one or two UMTS channels.
3. On the Frequency scanning, GSM page, click the Select Channels button to select the
GSM channels to be scanned.
Note that the scanner reports the 32 strongest channels from the selected GSM channels.
Channel style defines the style of the measured channel. For GSM the options are 200 kHz
and 30 kHz narrow.
NEMO SCANNER G UIDE 68
Data mode defines the type of measurement data computed from each sample. Note that the
available selection depends on the scanner type.
RX Level Average: the data reported is the average RX level, in dB, of the number of
samples.
RX Level Maximum: the data reported is the maximum RX level, in dB, of the number of
samples.
RX Level Minimum: the data reported is the minimum RX level, in dB, of the number of
samples.
RX Level Standard Deviation: the data reported is the standard of deviation of the
number of samples reported as an integer.
RX Level 10%: the data reported is the 10th percentile RX level, in dB, of the number of
samples.
RX Level 50%: the data reported is the 50th percentile RX level, in dB, of the number of
samples.
RX Level 90%: the data reported is the 90th percentile RX level, in dB, of the Number of
samples.
Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
Sample size defines the number of samples taken from each channel before a measurement
result is written to file.
Selecting the BSIC decoding option displays BSIC value in a measurement window.
BSIC Threshold defines the minimum BSIC level that the scanner reports.
BCCH C/I option is available with PCTEL and Rohde&Schwarz GSM scanners only.
4. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 69
TOP-N Pilot Scanning - UMTS
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode/Scanning.
To set pilot scanning settings:
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.
Note that some of the options are enabled/disabled in this dialog according to the
selected scanner model.
Channel style refers to the style of the channel. For UMTS scanners, the options are Narrow
Band (200kHz) and Wide Band (3.84MHz). For Anritsu scanners, only Wide Band is available.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Measurement period defines the time in milliseconds for which the scanner measures and then
reports the result.
NEMO SCANNER G UIDE 70
Number of fingers defines the maximum number of fingers used for RAKE in measurement.
Selective level determines a valid path. Set a value (in dB) to decide a valid path from the
noise floor (average value).
Rake threshold determines a valid path (in dB). Subtracting the set value from a path with a
maximum correlation value gives the lower limit of the valid path.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
Delay profile option enables/disables delay profile scanning. The Channel number field
provides a list of channels that can be selected for scanning.
Finger option enables and disables Finger measurements for the scanner.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for
each scrambling code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning. If you press the arrow, a drop-down menu will appear from where
you can select Top-N Search Configuration.
Please note that the Top-N Search Configuration dialog is available for Anritsu UMTS
scanners only.
NEMO SCANNER G UIDE 71
In the Top-N Search Configuration dialog you can limit the search performed by the scanner
and consequently speed up the search.
Group specifies the group number for the primary scrambling code in the range of 0 to 63.
Cell specifies the cell number for the primary scrambling code in the range of 0 to 7.
Secondary code specifies the secondary scrambling code. Limit range should be set from 0 to
0.
Channelization code specifies the channelization code. Limit range should be set from 0 to 0.
Search method defines how the search is performed. P-CPICH (primary common pilot
channel) searches with P-CPICH. SCH performs a three-step search with P-SCH and S-SCH.
To select pilot parameters:
1. Select the TOP-N Mode option.
2. Set the Number of Scrambling codes value. This defines how many strongest pilots are to
be reported by the scanner. The maximum is 32 pilots.
NEMO SCANNER G UIDE 72
To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N
Configuration button. The Select Channels dialog is opened.
2. The table displays the channel numbers, not the frequencies.
With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you
are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be
selected.
3. You can remove channels from the Selected list by selecting a channel and clicking the
Remove button.
4. You can add channels to the Selected list by selecting a channel from the Available list
and clicking the Add button.
5. Click OK to return to the Measurement Properties dialog.
NEMO SCANNER G UIDE 73
To select search parameters:
1. Open the Measurement Properties, Pilot scanning, UMTS page. Press down the Top-N
Configuration button and select Top-N Search Configuration.
2. The Top-N Search Configuration dialog opens.
NEMO SCANNER G UIDE 74
3. Set the Group search range. The group number is the scrambling code divided by 8. For
example, SC (scrambling code) 12 = group 1, cell 4.
4. Set the Cell search range. The cell number is the division modulus. For example, SC
(scrambling code) 12 = group 1, cell 4.
5. The Secondary Code and the Channelization Code ranges should be set from 0 to 0 for
scanning only the P-CPICH.
6. Select the Search Method. SCH means that the P-CPICH are searched using P-SCH and
S-SCH. P-CPICH means that the P-CPICH are searched without using P-SCH and S-SCH.
Note that the P-CPICH method is much slower than the SCH method.
7. Click OK to accept the settings and to return to the Measurement Properties dialog.
8. Data processing method defines how the scanner will process samples before reporting.
9. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data
processing method is used.
In pilot scanning mode, the RSSI is always measured for each channel.
In pilot scanning mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
10. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
11. A green light on the scanner Device Status window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
12. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 75
Pilot Scrambling Code Scanning
Pilot Scrambling Code Scanning or Known Scrambling Code Scanning can be used to scan
known pilots. The Known Scrambling Code Scanning will from now on be referred to as Normal
Pilot Mode.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. Go to the Measurement Properties, Pilot scanning, UMTS page .
3. Clear the TOP-N mode option and click the Select Channels button. The Select
Scrambling Codes dialog is opened.
4. Select channels in the Selected channel numbers table by clicking the Select button.
With the Anritsu ML8720B single carrier scanner only one channel can be selected. If you
are measuring with the Anritsu ML8720B-03 dual carrier scanner, two channels can be
selected.
5. For each selected channel, select scrambling codes. Select a channel and click the Select
button below the Selected scrambling codes table.
6. Click OK to return to the Measurement Properties dialog.
NEMO SCANNER G UIDE 76
7. When using an Anritsu scanner in Pilot Scanning mode, you can define the measurement
period. It defines the time period from which results are gathered and processed before
reporting.
8. Data processing method defines how the scanner will process samples before reporting.
In Pilot Scanning Mode the RSSI is always measured for each channel.
In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
9. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
10. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
11. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 77
DVB-H Scanning
DVB-H scanning can be performed with the Anritsu MS2721B DVB-H Analyzer scanner.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties, Pilot scanning, DVB-H page, select a frequency to be
measured. Anritsu MS2721B DVB-H Analyzer scans frequencies between (DVB-H) 474 -
850 MHz.
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
5. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 78
Spectrum Analyzer Measurements
Spectrum scanning can be performed with the Anritsu MS2721B Spectrum Analyzer scanner.
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page.
NEMO SCANNER G UIDE 79
3. Select the Enable spectrum scanning option and click on Add.
4. Define the start and stop frequencies within which the measurement will be performed. If
you manually define the start and stop frequencies, you can either select to add the
frequencies to the scanning list or save them as a predefined set. Select your option in the
Add to scanning list menu.
5. Select Set center frequency and bandwidth to define the center frequency and the
bandwidth to be measured. If you manually define the center frequency and bandwidth, you
can either select to add them to the scanning list, or save them as a predefined set. Select
your option in the Add to scanning list menu.
With Anritsu MS2721B spectrum analyzer the supported frequency range is from 9 kHz to
7.1GHz. The sample count is fixed to 551, and RBW is adjusted automatically. RBW is
between 1 Hz - 3 MHz. It is automatically adjusted to the closest value of 1 Hz, 3 Hz, 10 Hz,
30Hz, 100 Hz ... 300 kHz, 1 MHz, 3 MHz.
6. When signal volume is lower than -50dBm, selecting the Use preamplifier functionality in
the Measurement Properties dialog can increase the scanner’s measuring sensitivity,
hence slightly decreasing background noise. However, it is recommended that it is not
selected when signal volume is higher than -50dBm.
NEMO SCANNER G UIDE 80
7. You can add scanning sets in the Predefined scanning sets field through the Add to
Scanning List button. Click the arrow in the button and select Save as Predefined Set.
Define a name in the Enter Frequency Set Name field and click OK.
8. The name appears in the Predefined scanning sets field along with the chosen frequency
and/or bandwidth information selected in the Reporting field.
9. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
10. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
11. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 81
PCTEL SCANNERS
Frequency Scanning – PCTEL GSM/UMTS Scanners
Frequency scanning can be used to scan band power. It is also useful for checking that the
band is deselected and for finding out the center frequency.
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. In the Measurement Properties dialog, go to the Frequency scanning, UMTS page.
3. In the Channel style field, select the channel width. The options are narrow band (200 kHz)
and wide band (3.84 MHz).
To find out the center frequency used, set the Channel Style to 200 kHz and select all the
channels in the frequency region where the carrier should exist; for example, all channels
allocated to an operator. The center frequency will stand out in Frequency Scanning
mode. The received signal should be above the noise level in order to find out the center
frequency.
NEMO SCANNER G UIDE 82
4. Click the Select Channels button to open the Select Channels dialog.
5. The table displays the channel numbers, not the frequencies.
6. Remove channels from the Selected list by selecting a channel and clicking the Remove
button.
7. Add channels to the Selected list by selecting a channel from the Available list and clicking
the Add button.
8. Click OK to return to the Measurement Properties dialog.
9. Click OK and OK to close the Measurement Properties dialog and to re-start the scanner
with the new settings.
10. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
11. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 83
Frequency Scanning – PCTEL EX LTE Scanner
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties. By clicking
the Advanced button on the General page, you will access the Advanced Properties
dialog. Here you can enable and disable the integrated GPS receiver. This means you will
not need an external GPS receiver in order to collect position data.
2. On the Frequency scanning page, define the Channel style.
NEMO SCANNER G UIDE 84
3. By clicking the Select Channels button, you can access the Select Channels dialog.
4. Select one band from the list or all of them. You can also select one band at a time and add
the bands you want to scan. If all bands are selected, you have the possibility to select
Remove All | ... items from every band. Alternatively, if only one band is selected you can
remove only items from the current band through Remove All | ...items from current band.
The Available view provides a list of channels that are available for scanning. To add
channels to the Selected list, click on a number in the Available list and then click the Add
button or simply double-click a channel to add it to the Selected list. To select all available
channels for scanning, click the Add All button. An alternative method to select channels is
to type the channel numbers in the field at the bottom of the dialog and to click Add.
To remove channels from the Selected list, click on the channel you want to remove and
then click the Remove button or double-click the channel. To remove all channels, click the
Remove All button. You can select several channels simultaneously by holding down the
SHIFT key and clicking on the channels you want to add or remove.
5. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
6. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
7. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 85
Frequency Scanning – PCT GSM Scanner
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
3. Go to the Frequency scanning page.
Channel style refers to the style of the channel.
Selecting the BSIC decoding option displays BSIC value in a measurement window.
BSIC threshold defines the minimum BSIC level that the scanner reports.
Select the BCCH C/I option to activate C/I measurements for the BCCH channel. This option is
available with PCTEL GSM scanners only.
NEMO SCANNER G UIDE 86
4. By clicking the Select Channels button, you can access the Select Channels dialog.
5. Select one band from the list or all of them. You can also select one band at a time and add
the bands you want to scan. If all bands are selected, you have the possibility to select
Remove All | ... items from every band. Alternatively, if only one band is selected you can
remove only items from the current band through Remove All | ...items from current band.
The Available view provides a list of channels that are available for scanning. To add
channels to the Selected list, click on a number in the Available list and then click the Add
button or simply double-click a channel to add it to the Selected list. To select all available
channels for scanning, click the Add All button. An alternative method to select channels is
to type the channel numbers in the field at the bottom of the dialog and to click Add.
To remove channels from the Selected list, click on the channel you want to remove and
then click the Remove button or double-click the channel. To remove all channels, click the
Remove All button. You can select several channels simultaneously by holding down the
SHIFT key and clicking on the channels you want to add or remove.
Note that Sample size and Data mode are not enabled with PCT GSM frequency scanning
NEMO SCANNER G UIDE 87
6. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
7. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
8. Click the Start Recording button to start recording the results in an output file.
Frequency Scanning – PCTEL EVDO Scanners
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
3. Go to the Frequency scanning page.
Channel style refers to the style of the channel. For EV-DO scanners, the options are 1250
kHz Normal and 30 kHz Normal.
Sample size defines the number of samples taken from each channel before a measurement
result is written to file.
NEMO SCANNER G UIDE 88
4. By clicking the Select Channels button, you can access the Select Channels dialog.
5. Select one band from the list or all of them. You can also select one band at a time and add
the bands you want to scan. If all bands are selected, you have the possibility to select
Remove All | ... items from every band. Alternatively, if only one band is selected you can
remove only items from the current band through Remove All | ...items from current band.
The Available view provides a list of channels that are available for scanning. To add
channels to the Selected list, click on a number in the Available list and then click the Add
button or simply double-click a channel to add it to the Selected list. To select all available
channels for scanning, click the Add All button. An alternative method to select channels is
to type the channel numbers in the field at the bottom of the dialog and to click Add.
To remove channels from the Selected list, click on the channel you want to remove and
then click the Remove button or double-click the channel. To remove all channels, click the
Remove All button. You can select several channels simultaneously by holding down the
SHIFT key and clicking on the channels you want to add or remove.
6. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
7. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
8. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 89
TOP-N Pilot Scanning - UMTS
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode.
1. After the scanner is connected and activated in Nemo Outdoor, open the Measurement
Properties dialog by selecting Measurement | <device> | General Properties.
2. Go to the Pilot scanning page.
CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are
below the threshold, the pilots are not reported.
Channel style refers to the style of the channel.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Pilot measurement mode defines the measurement mode for pilot scanning.
In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,
weak pilots may be undetected.
In High dynamic mode scanning speed is lower but sensitivity is higher.
NEMO SCANNER G UIDE 90
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
Time of arrival defines if the selected scanner will measure the time of arrival for each
scrambling code. The time of arrival value is relative to GPS time and is measured in chips.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for
each scrambling code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.
To select channels:
1. In the Measurement Properties, Pilot scanning, UMTS page, click the Top-N
Configuration button. The Select Channels dialog is opened.
The table displays the channel numbers, not the frequencies. If you know the frequency
but not the channel number, the channel number can be calculated by multiplying the
frequency in MHz by five. The channel spacing is always 200 kHz.
2. Remove channels from the Selected list by selecting a channel and clicking the Remove
button.
3. Add channels to the Selected list by selecting a channel from the Available list and clicking
the Add button.
With a PCTEL LX scanner a maximum of 8 channels can be selected in the pilot mode.
With a PCTEL EX scanner a maximum of 15 channels can be selected in the pilot mode.
With a PCTEL MX scanner 1 channel can be selected in the pilot mode.
With a PCTEL LTE EX scanner a maximum of 15 channels can be selected in the pilot mode.
With a PCTEL PCT scanner a maximum of 4 channels can be selected in the pilot mode.
4. Click OK to return to the Measurement Properties dialog.
To select pilot parameters:
1. Select the TOP-N Mode option.
2. Set the Number of scrambling codes value. This defines how many strongest pilots are to
be reported by the scanner. The maximum is 32 pilots.
Note that with the PCTEL PCT Scanner the maximum number of pilots to be selected for
scanning is 8.
NEMO SCANNER G UIDE 91
Note that the PCTEL EX WCDMA scanner only supports the TOP-N mode. You can select
up to 32 pilots for scanning.
3. To improve on the accuracy of radio propagation models, High speed mode makes it
possible to acquire more samples (max 32 pilots per channel), while High dynamic mode
offers fewer samples (max 16 pilots per channel) with a larger dynamic range.
To set general parameters:
1. Data processing method defines how the scanner will process samples before reporting.
2. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data
processing method is used.
To select measured values:
In Pilot Scanning Mode the RSSI is always measured for each channel.
In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
1. In the Measurement Properties, Pilot scanning page:
Select the P-SCH option to enable P-SCH Ec/N0 and RSCP measurement.
Select the S-SCH option to enable S-SCH Ec/N0 and RSCP measurement.
Select the Time of arrival option to enable time of arrival measurement.
Select the Delay spread option to enable P-CPICH delay spread measurement.
Select the SIR option to enable P-CPICH SIR measurement.
Select the Delay profile option to enable P-CPICH Delay Profile measurement. In TOP-
N pilot scanning mode the scrambling code for delay profile measurement cannot be
selected.
2. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
3. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
4. Click the Start Recording button to start recording the results in an output file.
TOP-N Pilot Scanning - EVDO
Unknown Pilot scanning can be used for scanning unknown pilots or the strongest pilots. The
Unknown Pilot Scan will from now on be referred to as TOP-N Pilot Mode.
1. After the PCTEL LX/EX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
NEMO SCANNER G UIDE 92
3. In the Measurement Properties dialog, go to Pilot scanning page.
Channel style refers to the style of the channel.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Pilot window mode defines the position of the chips that are searched for pilot across in regard
to the ideal pilot position (0 chip delay for a given pilot).
Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1,
1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every
second sample is logged, with ratio 1:4 every 4th sample is logged, and with ratio 1:8 every 8th
sample is logged. By decreasing the sampling ratio you can decrease the output file size, but
the scanning accuracy will be diminished.
Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the
threshold, the pilots are not scanned.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
NEMO SCANNER G UIDE 93
Delay option enables/disables delay profile scanning. Delay is defined as the measured
difference between the expected arrival time (GPS time) and the actual arrival time of the
maximum peak above the PN threshold. It is reported in chips.
4. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
5. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
6. Click the Start Recording button to start recording the results in an output file.
Spectrum Scanning
Spectrum scanning is enabled on PCTEL EX scanners only in online mode. Hence, the
device needs to be added to Nemo Outdoor in online mode to activate the Spectrum
scanning functionality
1. After the PCTEL EX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page.
NEMO SCANNER G UIDE 94
3. Select the Enable spectrum scanning option, and click Add.
4. To create new scanning sets, define the scanning frequencies in the Reporting view.
Set start and stop frequencies defines the frequency range that will be scanned.
Set center frequency and bandwidth defines the frequency range that will be scanned.
The Sample count field determines the sample count measured for the given frequency range.
5. The Add to Scanning List menu enables you to decide whether the new scanning set is
added to the scanning list, or saved as a predefined set also for later use.
6. The Predefined scanning sets can be used to quickly select the frequency range to be
scanned. Select a set from the list, and click on Add to Scanning List.
With PCTEL EX scanning receivers, the internal frequency range is defined with start
frequency, resolution bandwidth (RBW) and number of points. Stop frequency = start frequency
+ (frequency spacing) * (number of points – 1). All the points need to be within the frequency
range of the requested RF Band. Frequency spacing is between the center frequencies and
spacing between points is half of the resolution bandwidth. The maximum number of samples
(points) is 2560. As seen in the formula above, stop frequency is calculated based on start
frequency and number of points. Stop frequency set by the user is only requested value but it is
not necessarily used during the measurement.
NEMO SCANNER G UIDE 95
If the requested frequency range is not supported by the device, Nemo Outdoor automatically
adjusts the frequency range for the device, and only frequency ranges supported by the
scanning receiver are used to make spectrum analyzer measurements. The number of samples
is used only for the frequency range supported by the scanning receiver. Nemo Outdoor does
not read the supported frequency range from the scanning receiver. For example, in the picture
below the user has set start and stop frequencies as seen within the red area. However, the
scanning receiver supports only frequency ranges shown by the green areas. The number of
samples is used only for green areas and the correct RBW is selected accordingly.
7. Click OK to return to the Spectrum scanning page.
NEMO SCANNER G UIDE 96
8. The added frequency ranges will be added to the Scanning list.
9. To remove items from the scanning list, select one or more, and select Remove All |
Remove Selected Items. Alternatively, click on Remove All to remove every item from the
list.
10. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
11. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
12. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 97
LTE OFDM Scanning
OFDM scanning can be used for scanning Reference signal / Sync signals with a PCTEL
LTE scanner and Nemo Outdoor.
1. After the PCTEL LTE scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. By clicking the Advanced button, you will access the Advanced Properties dialog. Here
you can enable and disable the integrated GPS receiver. This means you will not need an
external GPS receiver in order to collect position data.
3. In the Measurement Properties dialog, go to the Pilot scanning page.
Channel style refers to the style of the channel.
Cyclic prefix defines the type of signal the scanner is set to measure. With Autodetect
selected, the scanner will automatically detect the appropriate signal type.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
NEMO SCANNER G UIDE 98
Sampling ratio option is available for PCTEL EX scanners only. The available options are 1:1,
1:2, 1:4 and 1:8. With ratio 1:1 all samples (Pilotscan events) are logged, with ratio 1:2 every
second sample is logged, with ratio 1:4 every 4th sample is logged, and with ratio 1:8 every 8th
sample is logged. By decreasing the sampling ratio you can decrease the output file size, but
the scanning accuracy will be diminished.
RSSI threshold determines a valid path (in dB). Subtracting the set value from a path with a
maximum correlation value gives the lower limit of the valid path.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best cells. Number of cells field indicates the number of best cells you want the
scanning to notify you of. Up to 16 sectors are reported with specific cell ID.
CINR option activates/deactivates Carrier to Interference and Noise Ratio measuring. Carrier
refers to either reference signal power or sync signal power depending on the selected signal
type.
Time offset refers to the number of samples between P-SCH Primary Synchronization Signal
arrival time with respect to receiver frequency reference that is derived from GPS reference
time.
Sync signal refers to the ratio between the synchronization channel, i.e., primary and
secondary signal received power and the interference and noise from the same synchronization
signal set.
Reference signal refers to the ratio between the reference signal received power (RSRP) and
the interference and noise from the same reference signal set.
The Top-N Configuration button will open the Select Channels where you can select
channels for pilot scanning. The maximum number of channels that can be selected is device
specific.
NEMO SCANNER G UIDE 99
4. When you select LTE channels, you can also define some channel-specific settings. In the
LTE Channel Specific Settings dialog, select the channel from the Selected channels list
and define the settings.
Note that the available options are device specific.
Uplink-downlink configuration refers to LTE TDD frame structure.
Frame structure type 2 is applicable to TDD. Each radio frame of length ms 10307200 sf TT
consists of two half-frames of length ms 5153600 s T each. Each half-frame consists of five
subframes of length ms 107203 s T . The supported uplink-downlink configurations are listed in
the table below where, for each subframe in a radio frame, “D” denotes the subframe is
reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink
transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One s lot, Tslo t=15360 Ts
GPUpPTS
D wPTS
One radio frame , Tf = 307200Ts = 10 ms
One half -frame, 153600 Ts = 5 ms
30720 Ts
One subframe , 30720 Ts
GPUpPTS
D wPTS
Subframe #2 Subframe #3 Subframe #4Subframe #0 Subframe #5 Subframe #7 Subframe #8 Subframe #9
Frame structure type 2 (for 5 ms switch-point periodicity):
Uplink-downlink configuration
Downlink-to-Uplink Switch-point periodicity
Subframe number 0 1 2 3 4 5 6 7 8 9
NEMO SCANNER G UIDE 100
0 5 ms D S U U U D S U U U 1 5 ms D S U U D D S U U D 2 5 ms D S U D D D S U D D 3 10 ms D S U U U D D D D D 4 10 ms D S U U D D D D D D 5 10 ms D S U D D D D D D D 6 5 ms D S U U U D S U U D
5. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
6. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings.
7. Click the Start Recording button to start recording the results in an output file.
Pilot Scrambling Code Scanning
Known Scrambling Code Scanning can be used to scan known pilots. The Known Scrambling
Code Scanning will from now on be referred to as Normal Pilot Mode.
1. After the PCTEL LX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.
NEMO SCANNER G UIDE 101
3. Clear the TOP-N mode option and click the Select Channels button. The Select
Scrambling Codes dialog is opened.
4. Select channels in the Selected channel numbers table by clicking the Select button.
With a PCTEL scanner a maximum of 8 channels can be selected in the pilot mode.
5. For each selected channel, select scrambling codes. Select a channel and click the Select
button below the Selected scrambling codes table.
6. Click OK to return to the Measurement Properties dialog.
7. Data processing method defines how the scanner will process samples before reporting.
8. PN threshold defines the limit above which Ec/N0 peaks must go if Aggregated data
processing method is used.
In Pilot Scanning Mode the RSSI is always measured for each channel.
In Pilot Scanning Mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
9. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
10. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
11. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 102
DRT SCANNERS
Frequency Scanning
Frequency scanning can be used to scan band power. It is also useful for checking that the
band is deselected and for finding out the center frequency.
1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. You can enable or disable the integrated GPS receiver through the Advanced button. It is
also possible to use an external GPS device with the scanner.
3. In the Measurement Properties dialog, go to the Frequency scanning page.
4. In the Channel Style list box, select the channel width. The options are Wide Band (5000
kHz) and Wide Band 2 (10000 kHz).
NEMO SCANNER G UIDE 103
5. Click the Select Frequencies button to open the Select Frequencies dialog.
6. The table displays the available frequencies. Select and add them in the Selected view by
clicking on Add>>.
7. Remove frequencies from the Selected list by selecting a frequency and clicking the
Remove button.
8. Add frequencies in the Selected list by selecting a frequency from the Available list and
clicking the Add button.
9. Click OK to return to the Measurement Properties dialog.
10. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
11. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
12. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 104
Pilot Scanning
1. After the DRT WIMAX scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot scanning page.
Channel style refers to the style of the channel.
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is calculated.
Top-N option enables/disables TOP-N scrambling code scanning. If enabled, scanner will report
results from N best preambles. Number of preambles field defines how many preambles are
reported by the scanner in TOP-N mode.
CINR refers to the Carrier to Interference and Noise ratio value, in dB *100 (e.g., -16.34). It is
based on the requested reuse factor.
Preamble delay refers to the number of samples between expected arrival time and actual
arrival time of preamble with respect to GPS time reference. The values range from 0 to
1023+32. Each sample corresponds to 89.285 nanoseconds.
NEMO SCANNER G UIDE 105
Reuse factor refers to a system design parameter that can be manipulated to achieve the
desired balance between the interference and the network coverage. The WiMAX air interface
modulating waveform has been divided into three segments (Segment 0, 1 and 2). The
allocation of frequency sub-carrier into these three segments is done in such a way that e.g. a
downlink signal on segment 0 will not interfere with the downlink signal on segment 1. In a
Reuse Factor 1 measurement, contributions from all the three segments are considered in the
measured parameters, so that the CINRs are calculated from all the three segments. When
Reuse Factor 3 is selected, only the contribution of the desired segment is considered, and the
CINRs are calculated only from the same segment. As a broad guideline, measurements
performed with Reuse Factor 1 will provide the signal quality of the all the detected preambles
relative to each other, whereas the Reuse Factor 3 category of measurements will provide the
signal quality of preambles within the same segment.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
3. The Top-N Configuration button will open the Select Frequencies dialog where you can
select frequencies for scanning. The maximum number of frequencies that can be selected
is device specific.
NEMO SCANNER G UIDE 106
4. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
5. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
6. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 107
ROHDE & SCHWARZ TSMQ/TSML/TSMW SCANNERS
With Rohde & Schwarz TSMQ, TSML and TSMW scanners you can perform GSM frequency
scanning, GSM/UMTS scanning, CDMA TOP-N Pilot scanning, EVDO TOP-N Pilot scanning,
UMTS TOP-N Pilot scanning, and Spectrum scanning. In addition, it is possible to perform CW
scanning measurements with the TSMQ and TSML scanners and LTE measurements with the
TSMW scanner. It is possible to perform any of the measurements introduced below separately,
any combination of the measurements or all of them simultaneously.
Frequency Scanning
1. After the Rohde & Schwarz TSMQ/TSML scanner is connected and activated in Nemo
Outdoor, open the Measurement Properties dialog by selecting Measurement | <device> |
General Properties.
Selecting the BSIC decoding option displays BSIC value in a measurement window.
BSIC threshold defines the minimum BSIC level that the scanner reports.
NEMO SCANNER G UIDE 108
Select the BCCH C/I option to activate C/I measurements for the BCCH channel. This option is
available with the PCTEL GSM scanner only.
Cell information decoding. Mobile Network Code, Mobile Country Code and Cell ID
information can be decoded from BCCH messages. Note that this is only enabled in online
mode and if the option has been purchased with the scanner.
When the System information decoding option is selected, L3 messages are written in the log
file.
2. Click the Select Channels button to open the Select Channels dialog.
3. The table displays the channel numbers, not the frequencies.
4. Select one band from the Band list or all of them. You can also select one band at a time
and add the bands you want to scan. If all bands are selected, you have the possibility to
select Remove All | ... items from every band. Alternatively, if only one band is selected
you can remove only items from the current band through Remove All |...items from
current band.
5. Remove channels from the Selected list by selecting a channel and clicking the Remove
button.
6. Add channels to the Selected list by selecting a channel from the Available list and clicking
the Add button.
NEMO SCANNER G UIDE 109
7. Click OK to return to the Measurement Properties dialog.
8. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
9. A green light on the scanner Device Status window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
10. Click the Start Recording button to start recording the results in an output file.
TOP-N Pilot Scanning - UMTS
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. Go to the Pilot scanning, UMTS page to define UMTS-specific Pilot scanning settings.
CPICH Ec/No threshold defines the minimum level for the CPICH Ec/No. If the values are
below the threshold, the pilots are not reported.
Channel style refers to the style of the channel.
NEMO SCANNER G UIDE 110
Data processing method defines how the scanned data is processed by the scanner. In
aggregate method, the sum of all peak pilot Ec/Io values above the PN threshold is
calculated. If there are no peaks above the PN threshold, value -30 dB is returned for WCDMA.
Pilot measurement mode defines the measurement mode for pilot scanning.
In High speed mode scanning speed is higher but sensitivity is lower. In high speed mode,
weak pilots may be undetected.
In High dynamic mode scanning speed is lower but sensitivity is higher.
Top-N option enables/disables Top-N scrambling code scanning. If enabled, scanner will report
results from N best scrambling codes. Number of pilots field defines how many pilots are
reported by scanner in Top-N mode.
Note that the Rohde & Schwarz TSMQ, TSML-W, TSML-GW and TSMW scanners support
only TOP-N mode and High speed and High dynamic pilot measurement modes. In
addition, Data processing method and CPICH Ec/N0 threshold are supported general
settings, and P-SCH, S-SCH, Time of arrival, Delay spread and SIR are supported of the
scanning options.
Time of arrival defines if the selected scanner will measure the time of arrival for each
scrambling code. The time of arrival value is relative to GPS time and is measured in chips.
Delay spread defines if the selected scanner will also measure the delay spread value (in
chips) for each scanned scrambling code. Delay spread is determined as the difference
between the last and first component to break the threshold set in PN Threshold.
When the Missing neighbor detection option is selected, the missing neighbor information
event (NMISS) is written in the log file. You can view the missing neighbor information, for
example, in a grid view.
When the Neighbor list decoding option is selected, the NLIST (neighbor list) event is written
in the log file for both GSM and WCDMA.
Delay profile option enables/disables delay profile scanning. The Channel number field
provides a list of channels that can be selected for scanning.
P-SCH defines if the selected scanner will measure the P-SCH Ec/N0 value for each scrambling
code.
SIR (signal to interference ratio) defines if the selected scanner will measure the SIR value for
each scrambling code.
S-SCH defines if the selected scanner will measure the S-SCH Ec/N0 value for each scrambling
code.
When the System information decoding option is selected, L3 messages are written in the log
file.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
Note that with UMTS the maximum number of channels that can be scanned is 32
channels, and the maximum number of pilots per each channel is 32.
NEMO SCANNER G UIDE 111
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button to start recording the results in an output file.
TOP-N Pilot Scanning - CDMA/EVDO
Note that the EVDO measurements can only be performed in a proper way when a CDMA
2000 channel is measured as well. In this way, the time relationship between the different
PN offsets is resolved.
1. After the Rohde & Schwarz TSMQ scanner is connected and activated in Nemo Outdoor,
open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Pilot Scanning, CDMA page.
Pilot Ec/I0 threshold defines the threshold level for the pilot Ec/I0. If the values are below the
threshold, the pilots are not scanned.
NEMO SCANNER G UIDE 112
TOP-N mode option enables/disables TOP-N scrambling code scanning. Number of pilots
field defines how many pilots are reported by the scanner in TOP-N mode.
Overhead message decoding, when selected, enables the scanner to decode PCH
messages.
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
Note that the Rohde & Schwarz TSMQ scanner supports max 32 channels.
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 113
TOP-N Pilot Scanning - LTE
1. Open the Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. Go to the Pilot scanning, LTE page to define LTE-specific pilot scanning settings.
CINR option activates/deactivates Carrier to Interference and Noise Ratio measuring. Carrier
refers to either reference signal power or sync signal power depending on the selected signal
type.
Sync signal refers to the ratio between the synchronization channel, i.e., primary and
secondary signal received power and the interference and noise from the same synchronization
signal set.
Reference signal refers to the ratio between the reference signal received power (RSRP) and
the interference and noise from the same reference signal set.
NEMO SCANNER G UIDE 114
The Top-N Configuration button will open the Select Channels dialog where you can select
channels for pilot scanning.
When you select LTE channels, you can also define some channel-specific settings. In the LTE
Channel Specific Settings dialog, select the channel from the Selected channels list and
define the settings.
Note that the available options are device specific.
Uplink-downlink configuration refers to LTE TDD frame structure.
Frame structure type 2 is applicable to TDD. Each radio frame of length ms 10307200 sf TT
consists of two half-frames of length ms 5153600 s T each. Each half-frame consists of five
subframes of length ms 107203 s T . The supported uplink-downlink configurations are listed in
the table below where, for each subframe in a radio frame, “D” denotes the subframe is
reserved for downlink transmissions, “U” denotes the subframe is reserved for uplink
transmissions and “S” denotes a special subframe with the three fields DwPTS, GP and UpPTS.
One slot, Tslot=15360 Ts
GPUpPTS
DwPTS
One radio frame , Tf = 307200Ts = 10 ms
One half -frame, 153600 Ts = 5 ms
30720Ts
One subframe , 30720 Ts
GP UpPTS
D wPTS
Subframe #2 Subframe #3 Subframe #4Subframe #0 Subframe #5 Subframe #7 Subframe #8 Subframe #9
NEMO SCANNER G UIDE 115
Frame structure type 2 (for 5 ms switch-point periodicity):
Uplink-downlink configuration
Downlink-to-Uplink Switch-point periodicity
Subframe number 0 1 2 3 4 5 6 7 8 9
0 5 ms D S U U U D S U U U 1 5 ms D S U U D D S U U D 2 5 ms D S U D D D S U D D 3 10 ms D S U U U D D D D D 4 10 ms D S U U D D D D D D 5 10 ms D S U D D D D D D D 6 5 ms D S U U U D S U U D
3. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
4. A green light on the scanner Device Status window should start blinking. This means that the
device is working properly and scanning using the default settings. In TOP-N Mode this may
take a few seconds.
5. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 116
Spectrum Scanning
1. After the Rohde & Schwarz scanner is connected and activated in Nemo Outdoor, open the
Measurement Properties dialog by selecting Measurement | <device> | General
Properties.
2. In the Measurement Properties dialog, go to the Spectrum scanning page.
NEMO SCANNER G UIDE 117
3. In the Measurement Properties dialog, select the Enable spectrum scanning option.
Click Add.
4. To create new scanning sets, define the scanning frequencies in the Reporting view.
Set start and stop frequencies defines the frequency range that will be scanned.
Set center frequency and bandwidth defines the frequency range that will be scanned.
The Sample count field determines the sample count measured for the given frequency range.
With Rohde & Schwarz scanner receivers, the user can set the start and stop frequency
between 80MHz and 3000MHz. Sample counts are divided to the frequency range defined by
the user. The TSMx device has a native frequency resolution of 12.8 KHz. It should be noted
that the frequency shift cannot be lower than 12.8kHz, which sets the number of sample count
max. limit to 5000 samples. In case the selected frequency range and sample count require a
frequency shift lower than 12.8kHz, the sample count is automatically decreased. The sweep
speed, resolution bandwidth and sampling rate are fixed. The sweep speed is 1 GHz / 0.1 sec,
the resolution bandwidth is fixed at 30 kHz.
For example, if the start frequency is 80 MHz, and the stop frequency is 100 MHz, the total
measured bandwidth is 20 MHz. If the sample count is set to 20, power (RMS) is measured
from a 1 MHz bandwidth. With the frequency shift of 12.8 KHz ~ 78 samples are taken from
each 1 MHz bandwidth.
NEMO SCANNER G UIDE 118
The Add to scanning list menu enables you to decide whether the newly created scanning set
is added to the scanning list, or saved as a predefined set also for later use.
The Predefined scanning sets can be used to quickly select the frequency range to be
scanned. Select a set from the list, and click on Add to scanning list.
5. Click OK to access the Scanning list view.
6. The added frequency ranges will be added to the Scanning list.
7. To remove items from the scanning list, select one or more, and select Remove all |
Remove selected items. Alternatively, click on Remove all to remove every item from the
list.
8. After making the appropriate settings, click OK and OK again and go to online mode to start
the scanning.
9. A green light on the scanner Device Status window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
10. Click the Start Recording button to start recording the results in an output file.
NEMO SCANNER G UIDE 119
TROUBLESHOOTING SCANNERS
If a Scanner synchronization failed error message appears in the Output window, the scanner
is working properly, but the scanner did not find strong enough a CPICH in a short time period.
Nevertheless, the measurement will go on normally.
If a Scanner GPS locking failed error message appears in the Output window, the scanner is
working properly, but the scanner GPS has no fix or is not connected. The measurement will go
on normally, but the scanner accuracy is not as good as it is when the scanner GPS has a fix