CMS Tracker week – July 14-19, 2003 1
Noise in TOB modules and sensor Noise in TOB modules and sensor qualityquality
Noise in TOB modules and sensor Noise in TOB modules and sensor qualityquality
Regina DeminaUniversity of Rochester
CMS Tracker week – July 14-19, 2003 2
Module 876Module 876Module 876Module 876
Of the 16 modules tested at UCSB,
Observed peculiarity in module testing :
Noise on some channels increases with bias voltage.
Micro discharge effect (also seen in D0 sensors delivered by Micron)
CMS Tracker week – July 14-19, 2003 3
Module 876Module 876Module 876Module 876
Defects in channels 278 and 279. Not found in sensor probing
CMS Tracker week – July 14-19, 2003 4
Module 876Module 876Module 876Module 876
CMS Tracker week – July 14-19, 2003 5
Module 877Module 877Module 877Module 877
Defect (scratch) in channel 333. Not found in sensor probing
CMS Tracker week – July 14-19, 2003 6
Module 877Module 877Module 877Module 877
CMS Tracker week – July 14-19, 2003 7
Module 878Module 878Module 878Module 878
Defect in channel 377. Not found in sensor probing
CMS Tracker week – July 14-19, 2003 8
Module 878Module 878Module 878Module 878
CMS Tracker week – July 14-19, 2003 9
Module 880Module 880Module 880Module 880
Strip 91 a known pinhole in the first sensor.
CMS Tracker week – July 14-19, 2003 10
Module 880Module 880Module 880Module 880
CMS Tracker week – July 14-19, 2003 11
Module 868Module 868Module 868Module 868
Mid-sensor opens in channels 69-71 in the 1st sensor
CMS Tracker week – July 14-19, 2003 12
Module 868Module 868Module 868Module 868
CMS Tracker week – July 14-19, 2003 13
Module 883Module 883Module 883Module 883
Defect in channel 166. Not found in sensor probing
CMS Tracker week – July 14-19, 2003 14
Module 883Module 883Module 883Module 883
Scratch in channel 316
CMS Tracker week – July 14-19, 2003 15
Module 883Module 883Module 883Module 883
CMS Tracker week – July 14-19, 2003 16
Module 872Module 872Module 872Module 872
Defect in channel 303. Not found in sensor probing
CMS Tracker week – July 14-19, 2003 17
Module 872Module 872Module 872Module 872
Scratch in channel 344. Not found in sensor probing
CMS Tracker week – July 14-19, 2003 18
Module 872Module 872Module 872Module 872
CMS Tracker week – July 14-19, 2003 19
Summary Summary Summary Summary Module # Comments
875 Channel 384 has high noise, but no lithography error present. NOT SEEN IN SENSOR PROBING
874 Found High Istrip channel in 2nd sensor (294) causes noise. Remove 293-295 between sensors and module is good
873 Micro-discharge at channel 14 at 270 V (need to pluck 10-18 to remove cmn). No obvious sensor damage.
NOT SEEN IN SENSOR PROBING872 4 channels with noise increase with HV. 3 have obvious
lithographic error. NONE SEEN IN SENSOR PROBING871 Micro-discharge at channel 181 at 300 V (need to pluck 175-
187 to remove cmn). No obvious sensor damage. NOT SEEN IN SENSOR PROBING
870 Good883 Channel 166 has increasing noise with HV. Has lithographic
error (see picture). NOT SEEN IN SENSOR PROBING882 Good
CMS Tracker week – July 14-19, 2003 20
Summary Summary Summary Summary Module # Comments
881 Micro-discharge at channels 438-440 (need to pull 434-444 to stop high cmn).
Channels start discharging at 0V and get worse869 Micro-discharge at channels 29-30 (need to pull 24-36 to stop high
cmn) at 400 V868 3 mid-sensor opens, lithographic error (see photo). NOT FOUND IN
SENSOR PROBING880 NO PROBLEMS879 NO PROBLEMS878 Channel 377 has increasing noise vs bias. Lithographic error found
in second sensor (see picture). NOT SEEN IN SENSOR PROBING
877 Channel 334 has slightly higher noise at 550 V. Lithographic error found in first sensor. (See picture.) NOT FOUND IN SENSOR PROBING
876 Channels 278-279 have increasing noise vs. bias voltage. Sensor lithographic error found on both channels (see picture) NOT
FOUND IN SENSOR PROBING
CMS Tracker week – July 14-19, 2003 21
SummarySummarySummarySummary
• Out of 16 modules built 11 show some signs of micro discharge.
• Total number of noisy strips – 17
• Number of strips with high I strip – 1
• Number of strips with obvious lithographic error – 8
• Opens - 3
CMS Tracker week – July 14-19, 2003 22
Module 875Module 875Module 875Module 875
CMS Tracker week – July 14-19, 2003 23
Module 874Module 874Module 874Module 874
CMS Tracker week – July 14-19, 2003 24
Module 873Module 873Module 873Module 873
CMS Tracker week – July 14-19, 2003 25
Module 871Module 871Module 871Module 871
CMS Tracker week – July 14-19, 2003 26
Module 870Module 870Module 870Module 870
CMS Tracker week – July 14-19, 2003 27
Module 882Module 882Module 882Module 882
CMS Tracker week – July 14-19, 2003 28
Module 881Module 881Module 881Module 881
CMS Tracker week – July 14-19, 2003 29
Module 869Module 869Module 869Module 869
CMS Tracker week – July 14-19, 2003 30
Module 879Module 879Module 879Module 879