Post on 25-Apr-2018
transcript
Coventry & Solihull
Waste Disposal Company Ltd,
Bar Road, Coventry, CV3 4AN.
Telephone: (024) 7650 7400
Facsimile: (024) 7650 6154
E-moil: cswdc@cswdc.co.uk
Date:
Your Reference:
Our Reference:
01/02/08
mtfenv/retlet82]
MrN Gallagher
ENVIRONMENT AGENCY
Sentinel House
9 Wellington Crescent
FradleyPark
Lichfield
Staffordshire
WS 13 8RR
o» ini irffi-flSTER DOCUMENT
SENTWpUBLIC REGISTER
Dear Sir
COVENTRY & SOLIHULL WASTE DISPOSAL COMPANY Ltd. WASTE TO ENERGY PLANT:
PERMIT No NP3739PD
Please find enclosed Biannual reports for second halfof2007 and annual reports for
2007
I trust the above meets with your requirements, ifyou should require any further
information please do not hesitate to contact me.
Yours faithfully
Safety Health and Environment Advisor
Registered Office: as above Registered No: 02690488
Coventry S Solihull Waste Disposal Co. ltd., is o
company controlled jointly by Coventry City
Council and Solihuii Metropolitan Borough Council.
100% Recycled Paper
Annual Performance Report
The Coventry and Solihull Waste Disposal
Company Waste to Energy Plant
Permit No NP3739PD
Year 2007
Introdution
The Waste to Energy plant, which is located at Bar Road in
Coventry, disposes of Municipal Household waste arising in
Coventry and neighbouring Solihull. Small amounts of municipal
household waste, arising from other nearby local authorities is also
disposed of at the plant.
The plant is operated by The Coventry and Solihull Waste Disposal
Company Ltd.
For further information on the report, or for copies of the report the
contact the following representatives of the operator;
R.Scawin Environment and Performance Manager
M.Flounders Safety Health and Environment Advisor
Telephone Number 024 7650 7400
Plant Description
The main activity at the installation is to incinerate municipal waste
and to recover energy, in the form of steam, heat, and electricity, for
export to the local grid and factories.
A limited amount of hazardous waste, containing less than 1%
halogenated organic substances (as chlorine), is also burned with
the municipal waste.
The installation includes waste receipt and storage, waste heat
boilers, abatement of the exhaust gas, on-site storage of residues
and all systems for controlling and monitoring incinerator operation.
The plant design is capable of processing approximately 315,000
tonnes of waste per annum/36 tonnes per hour in three combustion
streams. The heat produced is used to generate 17.7MW of
electricity and 16MWt heat energy to a local industrial site.
The material is loaded into each of the furnaces via feed hoppers
from a reception hall, where the waste vehicles deposit their loads
into the storage bunkers. After entering the combustion chamber
via the refuse feed ram the material is allowed to fall onto the grate
in a controlled manner. The moving grate mechanisms are used to
agitate the waste as it progresses down to the ash discharge.
As the waste moves along, primary air is introduced from beneath
the grate enabling the waste to go through a series of drying and
burning areas. Re-circulated flue gas is introduced from above the
grate for combustion control. Auxiliary gas fired burners are located
in the combustion chamber both to heat it up on start up and to
maintain the final gas temperature.
The hot gases are maintained at a minimum temperature of 850°C
for 2 seconds in the combustion chamber before passing to the
boiler, economiser and abatement plant.
Each furnace is equipped with a 3-bank water tube boiler raising
steam at 17 bar and 208°C. Economisers are fitted down stream of
each boiler unit to pre-heat the incoming feed water.
Each incinerator line is provided with its own gas cleaning and
monitoring equipment. Gas cleaning comprises Flue Gas
Recirculation (FGR) and Ecotubes followed by activated carbon
injection, dry scrubbing with hydrated lime. The gasses pass
through bag filters to remove particulates prior to discharge to
atmosphere via one 92m stack.
Emissions from the stack are continuously monitored for
particulates, carbon monoxide (CO), sulphur dioxide (SO2),
hydrogen chloride (HCI), oxygen (O2), nitrogen oxides (NOx) and
volatile organic compounds (VOC).
There is no discharge of process liquids to controlled waters.
Uncontaminated surface and roof waters are discharged to the
surface water sewer system.
All process waste waters are discharged to foul sewer and these
are treated at Finham STW.
Bottom ash from the incinerator grate is quenched with water and
then conveyed to a concrete storage bunker prior to removal for
disposal in a landfill.
Air pollution control residues from the bag filters are collected
continuously and stored in an enclosed silo prior to removal for reuse
in a waste treatment facility to neutralise acids.
The ferrous fraction from the bottom ash is removed by magnetic
separation and stored in a bunker prior to removal for recycling for
steel making.
Summary of plant operation
The plant consists of three separate incinerator lines that incinerateup to 12 tonnes of waste per hour.
There are two electrical generating sets on the plant which utilise the
energy released from the waste incineration process. The generating
sets are designated as G1 and G2. G1 has a capacity of 12.9MW and
G2 a capacity of 4.8 MW. The process energy requirements are taken
from the electricity generated and the surplus is exported to the
community via the local grid.
The plant also exports heat, in the form of high pressure hot water, to
a local factory.
During 2007 the plant processed 230,800 tonnes of municipal waste.
The following table categorises the types and permitted maximum
amounts of wastes incinerated.
EWC Code
1912 01
19 12 12
bo oi oi
pOOl 08
E00201
Description Amount
paper and cardboard (confidential waste separately
collected)
other wastes (including mixtures of materials) from
mechanical treatment of wastes other than those
mentioned in 191211
paper and cardboard
biodegradable kitchen waste
biodegradable waste
ptO 03 01 mixed municipal waste
(20 03 02
2003 07
(2003 99 I13 0701* H
130899* h
15 0202* fcf[
150203 P
160708* to
19 12 10 K
190199 (\
waste from markets
>ulky waste
municipal waste not otherwise specified
ueloilanddiesel
wastes not otherwise specified
ibsorbents, filter materials (including oil filters not
rtherwise specified), wiping cloths, protective clothing
sontaminatfid by dangerous substances
ibsorbents, filter materials, wiping cloths and protective
lotting other than those mentioned in 15 02 02
vaste containing oil
Combustible waste (refuse derived fuel)
Pastes not otherwise specified
*5%
4%
4%
«90%
sO.1%
During 2007 the plant operated for the following hours on each
incinerator line.
Incinerator
line
1
2
3
Operating
hours
6839
7616
7667
Actual Percent
availability
78
86
86.5
Planned
Percent
availability
83.3
88
88
During 2007 there were planned outages for the following reasons.
Water washes on a quarterly basis on all three units
Planned maintenance on units 1,2 and 3.
Other periods which were not accounted for by the planned
availability to actual availability figures were primarily due to boiler
tube failures and grate failures.
The following table describes the type, amount and
destination/treatment of residues produced by the process
Residue
description
Incinerator
Bottom Ash
Air pollution
Control residue
Incinerated
metal
Quantity
produced
(tonnes)
49698
7486
4767
Destination/treatment
Landfill
Sorbant treatment with final
landfill
Recycled
The total energy generated by the plant in 2007 was:
Total electricity generated 104567MWh
Total electricity consumed on site 18875MWh
Total electricity to community 85692MWh
Total heat supply to local factory 17607MWh
The electricity exported to the community is equivalent for the
average lighting needs of 15000 to 20000 houses.
Summary of plant emissions
The Continuous Emission Monitoring System (CEMS) continuously
monitors the emissions to air of the following pollutants on each
unit:
Oxides of Nitrogen
Carbon Monoxide
Volatile organic Compounds
Particulates
Sulphur Dioxide
Hydrogen Chlorides
The CEMS continuously monitor the Dry and Wet Oxygen content
of the gasses for each unit to correct the data to normalised
conditions.
It also continuously monitors the gas flow rates for veach unit to
calculate mass release.
An attached appendix shows monthly average concentrations for
each pollutant on each unit.
During 2007 the CEMS operated normaly for 100% of the operating
time. The emissions to air from the process remained compliant
with the PPC Permit Emission Limit Values for half hourly averages
for all notifiable pollutants, except as described in the section
"Summary of plant compliance" which follows this section.
Graphs of the monthly average concentration for emissions of all
notifiable pollutants on the three incinerators are shown in
Appendix 3.
The Monthly average for Oxides of Nitrogen for all three units were
below 180mg/m3, the Daily Emission Limit Value set down in thePPC permit is 200 mg/m3
Dust levels, Hydrochlorides, and Sulphur dioxide have indicated
stable levels throughout the year (Appendix 3). Lines 1 & 2
demonstrate a high spike result in May and September
respectively. This was due to a bag failure in those months which
resulted in high, but still compliant, half hourly readings which
resulted in a higher monthly average.
Hydrocarbon results demonstrate very low monthly averages.
A summary table of the mass emissions for 2007 is shown in
Appendix 1
The combustion gasses, Carbon Dioxide, Carbon monoxide,
Oxides of Nitrogen and Hydrocarbons have shown an increase.
This is due to reduced usage of the eco-tubes as compared to
2006, and increased waste throughput.
Particulates have again shown further improvement due to the filter
bag replacement programme.
The mass emission results for heavy metals, cadmium, mercury,
dioxins and hydrocarbons are extrapolated from the periodic
monitoring carried out in November 2007. These results remain
compliant and do not indicate any significant deviation on previous
results.
Periodic sampling has been carried out 4 times during 2007 by an
external sampling house. All the results (apart from a manganese
sample) were below the PPC Permit Emission Limit Values. Where
applicable the results were comparable with the data generated by
the Continuous Emissions Monitoring equipment.
Periodic measurements are taken of the pollutants measured
continuously and also the following on each unit.
Heavy Metals
Mercury
Cadmium & thallium
Hydrogen Fluorides
Dioxins
PCB.s
Summary of plant compliance
There were three unauthorised releases to air under the
Company's PPC Permit Emission Limit values.
22/03/07 On line 2 the Half Hourly Emission Limit Value was
exceeded for both Carbon Monoxide and Hydrocarbons. The
cause was unsuitable highly volatile waste. To prevent re
occurrence the type of waste is to be rejected as unsuitable for
incineration.
24/06/07 On line 1 the Half Hourly Emission Limit Value was
exceeded for Carbon Monoxide. The cause was unstable
conditions in the process.
30/05/07 On line 2 the Periodic sampling Emission Limit Value
was exceeded for Manganese for the sampling tests carried out
in May. The figures reported were contested with the sampling
house carrying out the tests on the basis that the process would
be incapable of producing the pollutant in the phase measured.
The sampling house has responded indicating that the samples
may have become contaminated. A formal letter of explanation
has been requested for the Environment Agency from the
sampling house.
The above breaches of the permit conditions were formally
reported to the Environment Agency as required under the
Permit.
There have been 2 complaints regarding environmental
performance.
There was one complaint relating to dust fall out from the plant.
An investigation was carried out into this complaint and it was
found to be unsubstantiated, on the basis that the prevailing
wind conditions did not support the complaint.
There was one complaint of noise from the site which was
received by the Environment Agency. An investigation into the
complaint found that the source of the noise was the operation
of the soot blowers at night. The noise was being transmitted
through a temporary opening in the furnace hall wall, which was
being used to load/unload materials during a major unit outage.
It was identified that this would be a temporary occurrence for a
period of two weeks.
Summary of plant improvements
During 2006 as part of our PPC Permit improvement programme
we completed the following improvements:
9 New dedicated housing for CEMS Equipment built
• New participate sampling equipment installed
• New Hydrocarbon sampling equipment installed
• New software installed in CEMS to enable electronic reporting
Summary of information made available
The Company has a Website where the public can access
information about the Company and its processes.
An information brochure, which includes a process flow diagram,
can be obtained upon request to the Company's office.
Information on emission releases to air may be obtained from the
public registers which are held at the following addresses
Coventry City Council
Environmental Services dept
Broadgate House
Broadgate
Coventry
Environment Agency
Arthur Drive
Hoo Farm Industrial Estate
Worcester Road
Kidderminster
DY11 7RA
Visits to the plant may be arranged by contacting the Company's
office
During the course of 2007 there were 18 visits to the site by
interested external organisations. During the course of these visits
the Company's processes were described and the environmental
impact of the process was discussed. A list of the bodies visiting is
included below:
Lichfield Science Society
Coventry City Council scrutiny Committee
Tile Hill College
Environment Agency trainee Officers
Coventry City Council Health and Safety Department
Sandwell Council Officers
Loughborough University
Leicester City Council officers
Ernst and Young Accountants
Walsall Multicultural Group
Warwickshire County Council officers
Norgine Company
Solihull borough Councillors
Coventry City Council ward group (2 visits)
Probus group
BUPA
Groundworks Warwickshire
During 2007 external talks were given to external organisations by
the Safety Health and Environment Advisor. These talks informed
of the development of waste disposal in Coventry and a description
the present Company processes along with their environmental
impact. Following are the organisations visited.
Coventry Womens Institute
Styvechyle Mothers Union
Leek Wooton Womens Institute
Sydney Stringer School
Allesley ladies Club
M Flounders
Safety Health and Environment Advisor
20/01/07
APPENDIX 1 - MASS EMISSION DATA
MASS EMISSION SUMMARY 2007 (2006 COMPARATIVE) TONNES
PARAMETER
Hydrogen Chloride
Sulphur Dioxide
Oxides of nitrogen
Carbon Monoxide
Hydrocarbons
Particulates
Metals
Cadmium
Hydrogen Fluoride
Mercury
Dfoxlns (grammes)
Carbon Dioxide
UNIT1
1.80
5.87
70.65
9.77
0.12
0.86
0.0127
0.00293
0
0
0.0028
43990
MASS EMISSIONS - GRAMMES I
PARAMETER
Hydrogen Chloride
Sulphur Dioxide
Oxides of Nitrogen
Carbon Monoxide
Hydrocarbons
Particulates
Metals
Cadmium
Hydrogen Fluoride
Mercury
Dioxins (milligrammes)
Carbon Dioxide
(Tonnes)
2006
1.87
4.89
64.82
6.55
0.15
1.54
0.0237
0.00021
0
0.00033
0.00315
31826
UNIT 2
2.46
2.1
85.55
8.9
0.26
1.26
0.0193
0.00326
0
0
0.0051
49611
(Tonnes)
2006
1.97
2.43
68.28
6.57
0.05
0.78
0.0189
5.8E-05
0
5.8E-05
0.0027
38903
UNIT 3
2.81
1.6
92.08
11.6
0.12
0.47
0.0213
0.0034
0
0
0.0008
52699
(Tonnes)
2006
2.79
1.39
78.4
8.29
0.1
1.19
0.0152
0.00018
0
5.1E-05
0.0079
39880
>ER TONNE OF WASTE (Unless Stated) 2000 to 2007
TOTAL
7.07
9.57
247.3
30.28
0.514
2.58
0.0553
0.009
0
0
0.0087
146300
(Tonnes)
2006
6.63
8.71
211.5
21.41
0.3
3.51
0.0578
0.00045
0.00
0.00044
0.01375
110609
Grammes (Unless stated) TOTAL
2007
30.34
41.07
1061.4
129.9
2.3
11.07
0.23
0.038
0.00
0.00
0.000037
627897
2006
31.5
41.4
1006.2
101.9
1.4
16.7
0.3
0.0021
0.00
0.0021
0.000065
526208
2005
51
35
1491
136
7
33
0.16
0.0098
0.013
0.017
0.00007
600234
2004
48
26
1958
184
12
38
0.17
0.011
0.00004
0.015
8E-06
815378
2003
50
60
2000
130
7
35
0.3
0.002
0.06
0.015
0.00023
705960
2002
51
69
1936
188
18
33
0.3
0.0005
0.08
0.007
0.0007
711000
2001
41
87
1940
210
25
20
0.07
0.004
1.17
0.0016
0.0035
702519
2000
44
81
1842
201
25
20
0.75
0.006
1.39
0.74
0.0007
711035
28
APPENDIX 2 - MASS EMISSION SUMMARY
Mass emission per tonne waste • Oxides of Nitrogen and Carbon Monoxide
2500
2000
1500
1000
500
[—•— Oxides of Nitrogen
—■— Carbon Monoxide
• ■•'. '■'-M\>.V~.'J& ^s>>;fhz££a~i^i:
2000 2001 2002 2003 2004
Year
2005 2006 2007
Mass emission/Tonne waste • Sulphur Dioxide and Hydrogen Chloride
■ Hydrogen Chloride
Sulphur Dioxide
2000 2001 2002 2003 2004
Year
2005 2006 2007
29
Mass emission per tonne of waste - Particulafes and Hydrocarbons
Hydrocartwnsl
Partkailates J
2000 2001 2002 2003 2004
Year
2005 2006 2007
Mass emission per tonne of waste - Dioxins
0.004
2000 2001 2002 2003 2004
Year
2005 2006 2007
30
APPENDIX 3 MONTHLY EMISSIONS
Monthly Averages - Carbon Monoxide
Jan Feb mar Apr May June July Aug Sept Oct Nov Dec
Monthly Averages Sulphur Dioxide
60
SO
-Uniti
Unit 2
Unit 3
ELV
40
Jan Feb mar Apr May June July Aug Sept Oct Nov Dec
10
31
Monthly Averages - Oxides of Nitrogen
250
200
150
100
Until
Unit 2
Unit 3
ELV
V
tfj'lr'-''■',-''"* '-,.■"■ '■■':':' ; ■- ■"'■;': '."■-
Jan Feb mar Apr May June July Aug Sept Oct Nov Dec
Monthly Averages Hydrocarbons
12
Unit 2
Unit 3
ELV
&lm3'^$: i
^i:''v''4-'1^^'.J':»;'""''1:^t'-v-\:1"-^''?-,'•'-..'.'■ ■J\i?J.'"'"
'■H;jf1->.^-1,'s,-i.--.-!a?;.-
■.;:'rfe-^^v.^:V^'
v/v;
Feb mar
n
Apr
i n
May
n
June
Month
n
July
. n
Aug Sept Oct Nov Dec
32
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: A1 (dated 04/10/2005)
Six-monthly Reporting of Emissions to Air for the period from ...01/07/07. to...31/12/07
Emission Substance / Emission Resultl J Test Sample ^ Accreditation/ Uncertainty 1
Point Parameter Limit Value Method Date and Timespl Certification M: (5) 1[2] 1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
Participate Matter
VOC as Total Organic Carbon
(TOC)
Hydrogen chloride
Hydrogen fluoride
Carbon monoxide
Sulphur dioxide
Oxides of nitrogen (NO and NO2
expressed as NO2)
Cadmium & thallium and their
compounds (total)
Mercury and its compounds
Sb,As,Pb,CrlCo(CuJMnlNi
and V and their compounds
(total)
D!oxin$/fiirans(l-TEQ)«
DioxinJtePCBs(WHO-TEQ
Humans/Mammals)6
20 mg/m3 over minimum 1 hourperiod
20 mg/m3 over minimum 1 hour
period
30 mg/m3 over minimum 1 hour
period •
2 mg/m3 over minimum 1 hour
period v V
100 mg/m3 (average of tehour
averages) over minimum 4 hour
period
200 mg/m3 (average of %-hour
averages) over minimum 4 hour
penoa
400 mg/m3 (average of %-hour
averages) over minimum 4 hour
period /
0.05 mg/m3 over minimum 30
minute, maximum & hour period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period.
0.5 mg/m3 over minimum 30
minute, maximum 8 hour period
0.1 ng/im3 over minimum 6 hour,
maximum 8 hour period
no limit applies
NA
NA
NA
ND
NA
NA
NA
ND •
ND
0.0102
N/A
N/A
BSEN
13284-1
BSEN
12619
BSEN
1«Hs
US EPA26/26A
ISO12039
BS6089-
4.1
IS010849
,BSEN':14385
BSEN
!13211
BSEN
14365
BSEN
1948
30/05/07 09:30-10:37
*
29/05/07 16:06-17:13
29/05/07 16:06-17:13
29/05/07 16:06-17:13
McertsMM03 149
•
McertsMM03149
McertsMM03149
McertsMM03149
NA
ND
NA
0.0016
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: A8 (dated 04/10/2005)
Reporting ofPeriodically Monitored Emissions to Air for Dioxins Emission Point A3 for the period firom
01/07/07 .to...31/12/07
1 PERIODIC (EXTRACTIVE) SAMPLING RESULTS
Parameter
Dioxins and Furans
I-TEQ
WHO-TEQ
Huiripns/MaTnmals
WHO-TEQ- Birds
WHO-TEQ-Fish
Dioxins and Furans ng/1
Congeners < LoD**
assumed to be zero
0.0166
0.0187
0.0268
0.0186
Congeners < LoD**
assumed to be at
LoD
0.0166
0.0187
0.0268
0.0186
Uncertainty
Error
36.14
Limit
ng/1 I-TEQ
Sample Date
1 10.1 107/08/07 I
I I
I-
Notes: **LoD-limit of
Signed Date
(auth as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: A8 (dated 04/10/2005)
Reporting ofPeriodically Monitored Emissions to Air for Dioxins Emission Point A2 for the period from
01/07/07 .to...31/12/07
PERIODIC (EXTRACTIVE) SAMPLING RESULTS
Parameter
Dioxins and Furans ng/1
Congeners < LoD**
assumed to be zero
Congeners < LoD**
assumed to be at
LoD
Uncertainly
Error
Limit
ng/11-TEQ
Sample Date
Dioxins and Furans
I-TEQ 0.0027 0.0027 29.6 0.1 14/08/07
WHO-TEQ 0.0012 0.0012
WHO-TEQ - Birds 0.0048 0.0048
WHO-TEQ-Fish 0.0028 0.0028
Notes: **LoD - limit ofdetection
Signed Date.(authorised of Operator)
Permit Reference Number: NP3739PD Operator :CSWDC Ltd
Installation : Coventry EFW Facility Form Number: A8 (dated 04/10/2005)
Reporting ofPeriodically Monitored Emissions to Air for Dioxins Emission Point Al for the period from
01/07/07 .to...31/12/07
PERIODIC (EXTRAC ) SAMPLING RESULTS
Pararnstdr
Dioxins and Furans
I-TEQ
WHO-TEQ
WHO-TEQ-Biids
WHO-TEQ-Fish
Dioxins and Furans ng/1
Congeners < LoD**
assumed to be zero
0.0825
0.0967
0.1320
0.0983
Congeners < LoD**
assumed to be at
LoD
0.0825
0.0967
0.1320
0.0983
Uncertainty
Error
30.3
Limit
ng/1 I-TEQ
0.1
-
-
mm
Sample Date
07/08/07
Notes: **LoD - limit of
Signed Date.(auth sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWOC Ltd
Installation: Coventry EFW Facility Form Number: PI1 (dated 04/10/2005)
Reporting of Performance Indicators for the period 1st October 2007...to 31st December2007.
Annual Production/Treatment
Total Municipal Waste Incinerated
Total Separately collected fractions Incinerated
Electrical energy generated and exported
Electrical energy generated and used on installation
Other energy produced by the installation
7090$
0
21379000
5829000
8805200
tonnes
tonnes
KWhro
KWhrs
KWhrs
Environmental Performance Indicators
Electrical energy imported
Supplementary Gas
Mass of bottom ash produced
Mass of APC residues produced
Mass of carbon used
Mass of lime used
Water consumption
Effluent release to sewer
378
5.15
0.17
0.04
0.2
10.02
1.36
0.8
KWhrs
Ffrtonne
tonne/tonne
tonne/tonne
Kg/tonne
Kg/tonne
MTtonne
M°/tonne
Operator's comments:
Environmental performance indicators are per tonne of waste incinerated
Signed Date
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: PI1 (dated 04/10/2005)
Reporting of Performance Indicators for the period 1st July 2007...to 30th September2007.
Annual Production/Treatment
Total Municipal Waste Incinerated
Total Separately collected fractions Incinerated
Electrical energy generated and exported
Electrical energy generated and used on installation
Other energy produced by the installation
62519
0
18397000
5115000
2302200
tonnes
tonnes
KWhrs
KWhrs
KWhrs
Environmental Performance Indicators
Electrical energy imported
Supplementary Gas
Mass of bottom ash produced
Mass of APC residues produced
Mass of carbon used
Mass of lime used
Water consumption
Effluent release to sewer
2525
5.15
0.2
0.036
02
10.02
1.36
0.8
KWHRS
FfVtonne
tonne/tonne
tonne/tonne
Kg/tonne
Kg/tonne
M/tonne
M°/tonne
Operator's comments:
Environmental Performance indicators are per tonne of waste incinerated
Signed Date.
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: PI1 (dated 04/10/2005)
Reporting of Performance Indicators for the period 1st April 2007...to 30th June2007.
Annual Production/Treatment
Total Municipal Waste Incinerated
Total Separately collected fractions Incinerated
Electrical energy generated and exported
Electrical energy generated and used on installation
Other energy produced by the installation
62519
0
21700000
5855000
2302200
tonnes
tonnes
KWhre
KWhrs
KWhrs
Environmental Performance Indicators
Electrical energy imported
Supplementary Gas
Mass of bottom ash produced
Mass of APC residues produced
Mass of carbon used
Mass of lime used
Water consumption
Effluent release to sewer
425
6.3
0.18
0.027
0.2
10.02
136
0.8
kWHRS
Ff/tonne
tonne/tonne
tonne/tonne
Kg/tonne
Kg/tonne
M°/tonne
M*/tonne
Operators comments:
Environmental Performance indicators are per tonne of waste incinerated
Signed Date.
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation: Coventry EFW Facility Form Number: PI1 (dated 04/10/2005)
Reporting of Performance Indicators for the period 1st January 2007...to 31* March 2007.
Annual Production/Treatment
Total Municipal Waste Incinerated
Total Separately collected fractions Incinerated
Electrical energy generated and exported
Electrical energy generated and used on installation
Other energy produced by the installation
70806
0
24235000
6076000
8805200
tonnes
tonnes
KWhrs
KWhrs
KWhrs
Environmental Performance Indicators
Electrical energy imported
Supplementary Gas
Mass of bottom ash produced
Mass of APC residues produced
Mass of carbon used
Mass of lime used
Water consumption
Effluent release to sewer
168
5.15
0.22
0.04
0.2
10.02
1.36
0.8
KWhrs
Ff/tonne
tonne/tonne
tonne/tonne
Kg/tonne
Kg/tonne
M/tonne
M^/tonne
Operators comments:
Environmental performance indicators are per tonne of waste incinerated
Signed Date.
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation: Coventry EFW Facility Form Number: E1 (dated 04/10/2005)
Reporting of Energy Usage for the year ...2007.
Electricity*
Natural Gas
Gas Oil
TOTAL
MWh
tonnes
tonnes
-
115138
3230
118638
25030
613
25643
* Conversion factor for delivered electricity to prl mary energy
2005
2008
2007
Primary Energy
usage
97138
78348
128758
CO2
produced
20958
16884
25643
CO2 per unit
output
0.092
0.074
0.107
Operator's comments:
Signed
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator :CSWDC Ltd
Installation : Coventry EFW Facility Form Number: WU1 (dated 04/10/2005)
Reporting ofWater Usage for the year 2007.
Mains water
Site borehole
River abstraction
TOTAL WATER USAGE
201920
N/A
215358
417278
0.88
N/A
0.0.92
1.8
2005
2006
2007
Named
Water source
Main and River
Main and River
Main and River
Total
Water usage
386449
353773
417278
Water per unit
output
1.8
1.7
1.8
Operator's comments:
During 2006 river abstraction was reduced due to low river levels and abstraction plant problems resulting in higher consumption of mains water.
During 2007 boiler feed water became contaminated with oil resulting in excessive blowdowns and increased mains water consumption
Signed Date....*
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator :CSWDC Ltd
Installation : Coventry EFW Facility Form Number: S1 (dated 04/10/2005)
Reporting of Emissions to Sewer for the period from ...01/07/07 to...31/12/07.
Emission
Point
Substance-
Parameter
Sample Accreditatioi
Certification
Uncertainty
S1
<o <o
BS 6088-2.89
[1] The result given is the maximum value (or the minimum value in the case of a limit that is expressed as a minimum) obtained during the reporting period,
expressed in the same terms as the emission limit value. Where the emission limit value is expressed as a range, the result is given as the 'minimum -
maximum1 measured values.
[2] Where an internationally recognised standard test method is used the reference number is given. Where another method that has been formally agreed
with the Agency is used, then the appropriate identifier is given. In other cases the principal technique is stated, e.g. colorimetry.
[3] For non-continuous measurements the date and time of the sample that produced the result is given. For continuous measurements, or flow/time
proportional samples, the percentage of the process operating time covered by the monitoring is given.
[4] The accreditation status of the equipment and/or the monitoring organisation, as appropriate, for the methods used for both sampling and analysis.
[5] The uncertainty associated with the quoted result at the 95% confidence interval, unless otherwise stated.
Signed
(auth
Date
to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility
Reporting of Waste Disposal and Recovery for the year 2007.
Waste Disposal Recovery
Description Route Tonnes Tonnes |
1) Hazardous Wastes
Named haz. Waste
Air Pollution Control Residue
Other hazardous wastes
Total hazardous waste
2) Non-Hazardous Wastes
Incinerator bottom Ash
Incinerated Metal
Total non-hazardous waste
TOTALWASTE
Pretreatment and
landfill
Landfill
Recycling
-
7460
7460
48930
4890
53820
61280
0
0
0
4890
4890
Form Number: R1 (dated 04/10/2005)
2006
2006
2006
2007
2007
2007
Named
Waste
Air Pollution
Control Residue
Incinerator
Bottom ash
Incinerated
Metal
Air Pollution
Control residue
Incinerator
Bottom ash
Incinerated
Metal
Total
Waste
6520
44150
5050
7460
48930
4890
Waste per unit
output
0.031
0.21
0.024
0.032
0.21
0.021
operators comments:
Signed
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: Ash1 (dated 04/10/2005)
Reporting ofAsh Composition for the period from Jubyl*1 2007 .to December 31st 2007 2006
Ash Conipc
Bottom Ash
\silion (TOC/LOI)
LOI (%)
*
% Carbon (TOC)
W/w
*1.08
At least one ofLOI or TOC to be reported.
Ash Con
Bottom
Ash
APC
Residues
iposilion (h
Cd
0.00015
0.017
TI
N/A
N/A
Petals,
Hg
0.00006
0.052
j
Dioxii
Pb
0.0024
0.15
is, etc.) j
Cr
0.0027
0.0088
Cu
0.0292
0.05
Mn
0.022
0.052
Ni
0.00008
0.0039
As
0.0017
0.034
Co
0.0008
0*002
V
0.0087
0.0022
Zn
0.0079
0.55
dioxin
I-TEQ
ng/kg
5.5885
1533.6
]DIOXIN
WHO-TEQ ng/kg
Humans/mammal6.254
1748.37
Birds5.097
1668.67
Fish6.74
2685.67
Signed Date.
to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: Ash2 (dated 04/10/2005)
Reporting ofAsh Solubility for the period from July 1st 2007 .to...December 31st 2007
I Ash solubil
Bottom Ash
APC Residues
ly (Met,
mg/kg
0.004
0.011
-Us)
TI
mg/kg
N/A
N/A
Hgmg/kg
0.0005
0.0005
Pb
mg/kg
2.32
13
Cr
mg/kg
0.0159
0.04
Cu
mg/kg
6.042
0.22
Mn
mg/kg
0.085
0.01
Ni
mg/kg
0.05
1.2
As
mg/kg
0.034
0.07
Co
mg/kg
0.006
0.10
V
mg/kg
N/A
N/A
Zn
mg/kg
1.02
N/A
Sigrrasrepresentative of Operator)
Date.
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation: Coventry EFW Facility Form Number: A1 (dated 04/10/2005)
Six-monthly Reporting of Emissions to Air for the period from ...01/07/07 .to...31/12/07
Substance ■
Parameter mit Value
Result ' Test Sample Accreditation/
Method Date and Times M Certification ■'"Uncertainty
A3
A3
A3
A3
"A3
A3
A3
A3
A3
A3
A3
A3
Paniculate Matter
VOC as Total Organic Caitwn
CTOC)
Hydrogen chloride
Hydrogen fluoride
SJaSUOn mOTOXKie
Sulohurdioxkte
Oxides of nitrogen (NO and NO2
expressed as NO2)
Cadmium & thallium and their
compounds (total)
Mercury and its compounds
SblAslPb,Cr,Co,Cu,Mn,Ni
and V and their compounds
(total)
Dtaxms/furans(l-TEQ)8
DioxirvlilcePCBs(WHO.TEQ
Humans/Mammals)8
20 mg/m3 over minimum 1 hour
period
20 mg/m3 over minimum 1 hour
period
30 mg/m3 over minimum 1 hourperiod
2 mg/m3 over minimum 1 hour
period
100 mg/m3 (average of yt-hour
averages) over minimum 4 hour
period
200 mg/m3 (average of Khour
averages) over minimum 4 hour
period
400 mg/m3 (average of %4iour
averages) over minimum 4 hour
period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.05 mg/m3 over minimum 30
minute! maximum 8 hour period
0.5 mg/m3 over minimum 30
minute, maximum 8 hour period
0.1 ng/m3 over minimum 6 hour,
maximum 8 hour period
No flmlt applies
NA
NA
NA
ND
"NA
NA
NA
ND
ND
0.0206
N/A
N/A
BSEN
13284-1
BSEN
12619
BSEN
1911
US EPA
26/26A
ISO12039
BS6069-
4.1
IS010849
BSEN
14385
BSEN
13211
BSEN
14385
BSEN
1948
30/05/0716:11 -16:19
30/05/0713:56-15:08
30/05/0713:56-15:08
30/05/0713:56-15:08
McertsMM03 149
McertsMM03149
McertsMM03149
McertsMM03149
NA
NA
NA
0.0032
Emission
Substance/
Emission
Result1'
Test
Sample
^Accreditation/
Uncertainty
1
Poin
tParameter
LimitValue
Method
DateandTimes{Z]
Certification
'-'i]
[S]
1[2
]1
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Dioxin-likePCBs(WHO-TEQ
Fish)*
Diox
in-l
ikeP
CBs(WHO-TEQ
Birds)*
Dioxins/fu
rans(WHO-TEQ
Humans/Mammals)6
Dioxins
/fu
rans(WHO-TEQRsh)
6 Dioxins/fu
rans(WHO-TEQ
Bird
s)6
Poly-cyclicaromatic
hydr
ocar
bons
(PAHs)To
tal
Anth
anth
rene
Benz
o{a}
anth
race
ne
BenzD[bJfluoranthene
Benz
o|k]
fiuo
rant
hene
Benz
o[b]
naph
(2l1
-d}t
hi0j
ph«i
e
Benzo[c|phenarrthrene
Benz
o[gh
i]pe
ryle
ne
Benz
o[a]
pyre
ne
Choi
arrt
hren
e
Chrysene
Cydopenta{c,d)pyren8
Dibe
n2o[
ah]a
nthr
ac8n
e
DJbe
nzo[
a,i]
pyre
n8
Ruor
anth
ene
lndo[1,2,3-cd]pyrene
Naph
thal
ene
No
limi
tapplies
No
limi
tapplies
No
limitapplies
No
limitapplies
No
limi
tapplies
No
limitapplies
No
limi
tapplies
No
limitapplies
No
limitapplies
No
limi
tap
plie
s
No
limi
tapplies
No
limi
tap
plie
s
No
limitapplies
No
limitapplies
-
No
limi
tapplies
No
limitapplies
No
limi
tapplies
No
limi
tapplies
No
limi
tapplies
No
limi
tapplies
No
limi
tapplies
No
limi
tapplies
N/A
N/A
N/A
N/A
N/A
N/A
[2] The result given is the maximum value (or the minimum value in the case of a limit that is expressed as a minimum) obtained during the reporting period,
expressed in the same terms as the emission limit value. Where the emission limit value is expressed as a range, the result is given as the 'minimum -
maximum* measured values.
[2] Where an internationally recognised standard test method is used the reference number is given. Where another method that has been formally agreed
with the Agency is used, then the appropriate identifier is given. In other cases the principal technique is stated, e.g. gas chromatography.
[3] For non-continuous measurements the date and time of the sample that produced the result is given. For continuous measurements the percentage of the
process operating time covered by the result is given.
[4] The accreditation status of the equipment and/or the monitoring organisation, as appropriate, for the methods used for both sampling and analysis.
[5] The uncertainty associated with the quoted result at the 95% confidence interval, unless otherwise stated.
[6] The result to be reported as a range based on: All congeners less than the detection limit assumed to be zero as a minimum, and all congeners less than
the detection limit assumed to be at the detection limit as a maximum-see also reporting form A9.
Signed s//a£s^11 Date.
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation : Coventry EFW Facility Form Number: A1 (dated 04/10/2005)
Six-monthly Reporting of Emissions to Air for the period from ...01/07/07 .to...31/12/07
Darameti lit Value
Test
Method
Sample
Date and Times
Accreditation;
Certification '"'Uncertainty
IA2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Paniculate Matter
VOC as Total Organic Carton
(TOC)
Hydrogen chloride
Hydrogen fluoride
Carbon monoxide
Sulphur dioxide
Oxides of nitrogen (NO and NO2
expressed as NO2)
Cadmium & thallium and their
compounds (total)
Mercury and its compounds
Sb,As,Pb,Cr,Co,Cu,Mn,Ni
' and V and their compounds
(total)
Dtaxfos/furans{l-TEQ)»
DioxirHikePCBs(WHO-TEQ
Humans/Mammals)8
20 mg/m3 over minimum 1 hour
period
20 mg/m3 over minimum 1 hour
period
30 mg/m3 over minimum 1 hour
period
2 mg/m3 over minimum 1 hour
period
100 mg/m3 (average of 1Mour
averages) over minimum 4 hour
period
200 mg/m3 (average of H-hour
averages) over minimum 4 hour
penoo
400 mg/m3 (average of yrhour
averages) over minimum 4 hour
period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.5 mg/m3 over minimum 30
minute, maximum 8 hour period
0.1 ng/m3 over minimum 6 hour,
maximum 8 hour period
no limit applies
NA
NA
NA
ND
NA
NA
NA
ND
ND
0.1392
N/A
N/A
BSEN
13284-1
BSEN
12619
BSEN
1911
US EPA
26J26A
ISO12039
BS6069-
4.1
IS010849
BSEN
14385
BSEN
13211
BSEN
14385
BSEN
1948
30/05/07 12:48-13:56
30/05/07 11:00-12:38
30/05/07 11:00-12:38
30/05/07 11:00-12:38
•
McertsMM03 149
McertsMM03149
McertsMM03149
McertsMM03149
NA
NA
NA
0.0217
Emission
Point
Substance
/
Parameter
Emission
LimitValue
Result1
'Test
Method
[2]
Sample
DateandTimes
Accreditation/
Certification
'•'''
Uncertainty
15)
1A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Dioxin-likePCBs(WHO-TEQ
Fish)6
DtaxMePCBs(WHQTEQ
Birds)*
Dtad
ns/f
uran
s(WHO-TEQ
Humans/Mammals)6
Dtad
ns/f
uran
s(WHO-TEQ
Fish)
6 Dioxins/fu
rans(WHO-TEQ
Birds)6
Poty
-cyd
icar
omat
ic
hydr
ocar
bons
(PAHs)Total
Anth
anth
rene
Benzo{a}anthracen8
Benzolbjfluoranthene
Benz
opcj
fluo
rant
hene
Benz
o[b]
naph
(2,1
-d}t
hiop
hene
Benzo[c]phenanthrene
Benzo[ghl]perylen8
Benzolajpyrene
Chol
anth
rene
Chiysene
Cydopenta(c,d)pyiefl8
Dibe
nzo[
ah]a
nthr
acen
8
Dibe
nzo[
a,i]
pyre
ne
Ruor
anih
ene
lndo
[1>2
,3-c
xj]p
yren
8
Naph
thal
ene
No
limi
tapplies
No
limi
tap
plie
s
No
limi
tapplies
No
limi
tap
plie
s
No
limi
tapplies
No
limitap
plie
s
No
limitapplies
No
limitap
plie
s
No
limitapplies
No
limitapplies
No
limitapplies
No
limi
tapplies
No
limitap
plie
s
No
limi
tap
plie
s
No
limi
tapplies
No
limitapplies
No
limitap
plie
s
No
limi
tap
plie
s
No
limitap
plie
s
No
limitapplies
No
limitapplies
No
limitap
plie
s
N/A
N/A
N/A
N/A
N/A
N/A
\2] The result given is the maximum value (or the minimum value in the case of a limit that is expressed as a minimum) obtained during the reporting period,
expressed in the same terms as the emission limit value. Where the emission limit value is expressed as a range, the result is given as the 'minimum -
maximum1 measured values.
[2] Where an internationally recognised standard test method is used the reference number is given. Where another method that has been formally agreed
with the Agency is used, then the appropriate identifier is given. In other cases the principal technique is stated, e.g. gas chromatography.
[3] For non-continuous measurements the date and time of the sample that produced the result is given. For continuous measurements the percentage of the
process operating time covered by the result is given.
[4] The accreditation status of the equipment and/or the monitoring organisation, as appropriate, for the methods used for both sampling and analysis.
[5] The uncertainty associated with the quoted result at the 95% confidence interval, unless otherwise stated.[6] The result to be reported as a range based on: All congeners less than the detection limit assumed to be zero as a minimum, and all congeners less than
the detection limit assumed to be at the detection limit as a maximum-see also reporting form A9.
Signed^^(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation: Coventry EFW Facility Form Number: A1 (dated 04/10/2005)
Six-monthly Reporting of Emissions to Air for the period from ...01/07/07 .to...31/12/07
Emission Substance/ Emission Result Test Sample Accreditation/ Uncertainty 1
Point Parameter Limit Value Method Date and Times ("J Certification |:>] I
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
Particulate Matter
VOC as Total Organic Carbon
(TOC)
Hydrogen chloride
Hydrogen fluoride
Carbon monoxide
Sulphur dioxide
Oxides of nitrogen (NO and NO2
expressed as NO2)
Cadmium & thallium and their
compounds (total)
Mercuiy and its compounds
Sb, As, Pb, Cr, Co, Cu, Mn, Ni
and V and their compounds
(total)
Dbxins/furans(l-TEQ)6
CHoxin4ikePCBs(WHO-TEQ
Humans /Mammals)8
20 mj
perkx
An3 over minimum 1 hour
20 mg/m3 over minimum 1 hour
period
30 mg/m3 over minimum 1 hour
P&lOQ
2 mg/m3 over minimum 1 hour
penoa
100 mg/m3 (average of Vi-hour
averages) over minimum 4 hour
pertou
200 mg/m3 (average of 14-hour
averages) over minimum 4 hour
pentxi
400 mg/m3 (average of 1/«-hour
averages) over minimum 4 hour
period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.05 mg/m5 over minimum 30
minute, maximum 8 hour period
05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.1 ng/m3 over minimum 6 hour,
maximum 8 hour period
No limit applies
2.68
1.2
9.38
ND
20.5
3.6
226.6
0.0067
ND
0.029
0.0825
0.0036
BSEN
13284-1
BSEN
12619
BSEN
1911
US EPA
26/26A
ISO12039
BS6069-
4.1
IS010849
BSEN
14385
BSEN
13211
BSEN
14385
BSEN
1948
09/08 09:20-10:25
09/08 0920-11:20
07/08 10:20-11:20
09/08 09:20-10:25
09/08 09:20-11:20
09/08 09:20-1120
09/08 11:20-13:20
09/08 10:50-11:55
09/08 10:50-11:55
09/08 10:50-11:55
07/08 11:58-18:07
07/08 11:58-18:07
McertsMM03149
McertsMM03149
McertsMM03149
McerteMM03149
Mc8rtsMM03149
McertsMM03149
McertsMM03149
Mcert8MM03149
Mcerts MM 03149
McertsMM03149
Mcerts MM 03149
Mcerts MM 03149
0.29
0.16
1.38
N/A
4.11
0.17
10.68
0.0010
N/A
0.0045
0.025
0.0011
Emission Substance
Parameter
emission
Limit Value
Result nj Test Sample Accreditation
Method Date and Times ['r) Certification
1A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
Dioxin-JikePCBs (WHO-TEQ
Fish)*
Dk»divlikePCBs (WHO-TEQ
Birds)6
Dioxins/furans (WHO-TEQ
Humans /Mammals)6
Dioxins / furans (WHO-TEQ Rsh)
8
Dioxins /furans (WHO-TEQ
Birds)6
Poly-cyclic aromatic
hydrocarbons (PAHs) Total
Arrthanthrene
Benzo{a}anthracen6
Benzo[b]fluoranth8ne
Benzo[k]fluoranttiene
Benzo[b]naph(2,1-d}thiophene
Benzo[c]phenanthrene
Benzo^lpeiylene
Benzo[a]pyrene
Cholanthnene
Chrysene
Cyclopenta{c,d)pyrene
Dibenzo[ah]anthracen8
Dfoenzo[a,l]pyrene
Ruoranthene
lndo[1(2,3<xflpyrene
Naphthalene
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
0.0002
0.0085
0.0987
0.0983
0.1320
0.1873
0.0078
0.0065
0.0072
0.0072
0.0066
0.0065
0.0078
0.0072
0.0072
0.0065
0.0064
0.0079
0.0086
0.0063
0.0078
0.0799
07/08 11:58-18:07
07/08 11:58-18:07
07/08 11:58-18:07
07/08 11:58-18:07
07/08 11:58-18:07
08/08 09:45-15:45
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
Meats MM 03149
McertsMM03149
0.0001
0.0026
0.0293
0.0298
0.04
0.042
[1] The result given is the maximum value (or the minimum value in the case of a limit that is expressed as a minimum) obtained during the reporting period,
expressed in the same terms as the emission limit value. Where the emission limit value is expressed as a range, the result is given as the 'minimum -
maximum* measured values.
[2] Where an internationally recognised standard test method is used the reference number is given. Where another method that has been formally agreed
with the Agency is used, then the appropriate identifier is given. In other cases the principal technique is stated, e.g. gas chromatography.
[3] For non-continuous measurements the date and time of the sample that produced the result is given. For continuous measurements the percentage of the
process operating time covered by the result is given.
[4] The accreditation status of the equipment and/or the monitoring organisation, as appropriate, for the methods used for both sampling and analysis.
[5] The uncertainty associated with the quoted result at the 95% confidence interval, unless otherwise stated.
[6] The result to be reported as a range based on: All congeners less than the detection limit assumed to be zero as a minimum, and all congeners less than
the detection limit assumed to be at the detection limit as a maximum-see also reporting form A9.
Signed .yjL/Jhrf^ Date.
to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator :CSWDC Ltd
Installation: Coventry EFW Facility Form Number: A1 (dated 04/10/2005)
Six-monthly Reporting of Emissions to Air for the period from ...01/07/07 .to...31/12/07
Emission Substance/ Emission Resultm Test ^ Sample ^ Accreditation/ Uncertainty 1Point Parameter Limit Value Methodm Date and Timesm Certification " H |
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Paniculate Matter
VCX; as Total Organic Carbon
(TOC)
Hydrogen chloride
Hydrogen fluoride
Carbon monoxide
Sulphur dioxide
Oxides of nitrogen (NO and NO2
expressed as NO2)
Cadmium & thallium and their
compounds (total)
Mercury and its compounds
Sb,As,Pb,Cr1CofCu,MnINi
and V and their compounds
Dioxins/furans(l-TEQ)6
Dioxin-likePCBs(WHO-TEQ
Humans /Mammals)9
Dioxin-]ikePCBs(WHO-TEQ
Rsh)6
20 mg/m3 over minimum 1 hour
period
20 mg/m3 over minimum 1 hour
penoo
30 mg/m3 over minimum 1 hour
2 mg/m3 over minimum 1 hour
period
100 mg/m3 (average of %-hour
averages) over minimum 4 hour
penou
200 mg/m3 (average of %4*our
averages) over minimum 4 hour
penoo
400 mg/m3 (average of K-hour
averages) over minimum 4 hour
period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.05 rng/m5 over minimum 30
minute, maximum 8 hour period
0.5 mgftn3 over minimum 30
minute, maximum 8 hour period
0.1 ng/m3 over minimum 6 hour,
maximum 8 hourperiod
No limit applies
No limit applies
1.28
0.3
10.27
ND
13.4
20.1
253.5
0.0062
ND
0.047
0.0027
0.0012
0.0001
BS EN 13284-1
BS EN 12819
BS EN 1911
USEPA26/26A
ISO12039
BS6069-4.1
IS010849
BS EN 14385
BS EN 13211
BS EN 14385
BS EN 1948
13/08 11:45-12:53
13/08 10:20-12:20
13/08 10:25-1126
13/08 10:20-12:20
13/08 12-20-14:20
13/08 1220-14:20
13/08 10:20-12:20
13/08 12:50-13:58
13/08 12:50-13:58
13/08 1250-13:58
14/08 09:30-15:45
14/08 09:30-15:45
14/08 09:30-15:45
Moots MM 03149
McertsMM03149
McertsMM03149
McertsMM03149
McerfeMM03149
McertsMM03149
McertsMM03149
McertsMM03149
Mc8rtsMM03149
McertsMM03149
McertsMM03149
Moots MM 03149
McertsMM03149
0.14
0.06
1.51
N/A
1.86
1.24
11.81
0.0008
N/A
0.0064
0.0008
0.0004
0.0000
Emission
Point
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
MlTheresul
Substance /
Parameter
DioxirvlikePCBs(WHO-TEQ
Kids)6
Dioxins/furans(WHO-TEQ
Humans/Mammals)6
Dioxins /furans (WHO-TEQ Fish)6
Dioxins / furans (WHO-TEQ
Birds)6
Poly-cydic aromatic
hydrocarbons (PAHs) Toy
Anthanthrene
Benstfajanfluacene
Benzo[b]fluoranttiene
Benzotkjfluoranthene
BCT2O[b]napii{2,1<J}thiophen8
Benzo[c]ph8nanthrene
Ben20[ghi]pery!8fie
Befi2D[a]pyren8
Cholarrthrene
Chrysene
Cyctopentalcdjpyrene
Diben20[ahJanthracen8
Diben20[a,i]pyrene
Ftaanthene
lndo[1£3<xllpyrene
Naphthalene
t given is the maximum vak
Emission
Limit Value
No limit applies
No limit applies
No limit applies
No limit applies
No limit applies
no limn appnes
&l*h ft ■ Mill niiwtinnno uirai appnes
no until applies
No limit appTtss
No limit applies
No Omit applies
No limit applies
No Omit applies
No limit applies
No limit applies
No limit applies
No Omit applies
No limit applies
No limit applies
NofimltappOes
No Kmit applies
je (or the minimum value in t
Result Pj
0.0027
0.0012
0.0028
0.0048
0.1048
0.0057
0.0047
0.0052
0.0052
0.0049
0.0047
0.0057
0.0052
0.0053
0.0047
0.0047
0.0058
0.0063
0.0042
0.0057
0.0266
le case of a
Test Sample
Method i?) Date and Times [z]
imitthatisext
14/08 09:30-15:45
14/08 09:30-15:45
14/08 09:30-15:45
14/08 09:30-15:45
14/08 09:30-15:45
tressed as a minimumi
Accreditation/
Certification '"'
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
obtained durina the
Uncertainty 1
0.0008
0.0009
0.0008
0.0014
0.0235
reoortina oeriod.
expressed in the same terms as the emission limit value. Where the emission limit value is expressed as a range, the result is given as the 'minimum -maximum1 measured values.
[2] Where an internationally recognised standard test method is used the reference number is given. Where another method that has been formally agreedwith the Agency is used, then the appropriate identifier is given. In other cases the principal technique is stated, e.g. gas chromatography.
[3] For non-continuous measurements the date and time of the sample that produced the result is given. For continuous measurements the percentage of the
process operating time covered by the result is given.
[4] The accreditation status of the equipment and/or the monitoring organisation, as appropriate, for the methods used for both sampling and analysis.
[5] The uncertainty associated with the quoted result at the 95% confidence interval, unless otherwise stated.
[6] The result to be reported as a range based on: All congeners less than the detection limit assumed to be zero as a minimum, and all congeners less than
the detection limit assumed to be at the detection limit as a maximum-see also reporting form A9.
Signed
(authorised to sign as representative of Operator)
Permit Reference Number: NP3739PD Operator: CSWDC Ltd
Installation: Coventry EFW Facility Form Number: A1 (dated 04/10/2005)
Six-monthly Reporting of Emissions to Air for the period from ...01/07/07 .to...31/12/07
Minstanc
Limit Value
Tost
Method
Sampl
Date and Ti
Accreditation,
Certification '
Uncertainty
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
Particulate Matter
VOC as Total Organic Carbon
(TOC)
Hydrogen chloride
Hydrogen fluoride
uaroon monoxiue
Sulphur dioxide
Oxides of nitrogen (NO and NO2
expressed as NO2)
Cadmium & thallium and their
compounds (total)
Mercury and Its compounds
Sb,AslPb,Cr,Co,Cu,MntNi
and V and their compounds
Dioxins/furans(l-TEQ)«
DloxiivlikePCBs(WHO-TEQ
Humans /Mammals)8
Dloxin4ikePCBs(WHO-TEQ
Rsh)«
20 mg/m3 over minimum 1 hour
period
20 mg/m3 over minimum 1 hour
penoo
30 mg/m3 over minimum 1 hour
period
2 mg/m3 over minimum 1 hour
period
100 mg/m3 (average of %-hour
averages) over minimum 4 hour
penod
200 mgftn3 (average of Mi-hour
averages) over minimum 4 hour
penoo
400 mg/m3 (average of 1/j-hour
averages) over minimum 4 hour
period
0.05 mg/m3 over minimum 30
minute, maximum 8 hour period
0.05 mg/m3 over minimum 30
minute, maximum B hour period
0.5 mg/m3 over minimum 30
minute, maximum 8 hour period
0.1 hg/m3 over minimum 6 hour,
maximum 8 hour period
No limit applies
No limit applies
17.72
1.5
10.83
ND
8.3
3.8
226.3
0.0066
ND
0.0391
0.0166
0.0016
0.0001
BS EN 13284-1
BS EN 12619
BS EN 1911
USEPA26/26A
ISO12039
BS6069-4.1
IS010849
BS EN 14385
BS EN 13211
BS EN 14385
BS EN 1948
09/08 09:58-10:43
08/08 10:30-12:30
09/08 12*2-13:02
08/08 15:55-16:55
08/08 10:30-12:30
08/08 10:30-12:30
08/08 10:30-12:30
09/08 10:55-12:55
08/08 10:30-12:30
08/08 10:30-12:30
07/08 09:48-15:57
07/08 09:48-15:57
07/08 09:48-15:57
McertsMM03149
McerfeMM03149
MoertsMM03149
McertsMM03149
Meats MM 03149
McectsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
MoertsMM03149
1.93
0.26
1.59
N/A
0.48
0.19
10.8
0.001
N/A
0.0061
0.006
0.0005
0.0000
Emission
Substance
/Emission
Resultl
'Test
Sample
^Accreditation/
Uncertainty
1
Point
Para
mete
rLi
mitValue
Methodm
Date
andTi
mes[
Z]Certification
iA}[b]
1A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A3
A
Dioxin-likePCBs(WHO-TEQ
Bird
s)6
Dioxins/furans(WHO-TEQ
Humans/Mammals)6
Woxlns
/furans(WHO-TEQ
Fish)
6 Dtodns
/furans(WHO-TEQ
Bird
s)6
Poly-cyclicar
omat
ic
nyarocafuOfts(pahs)Total
Anth
snlh
iene
Benz
o{a}
anth
rac6
n8
Benzc{b]fluoranthene
Benz
o[k]
fluo
ranm
ene
Benzo[b]naph(2,1-<J}thtophene
Benzo[c]phenanthrene
Benzo[ghi]perylene
Benzo[alpyiene
Chol
anth
rene
Chiysene
Cyclopenta(cd}pyTene
Mbenzo{ah]anthrac8n8
Dibenzo(a1i]pyrene
Ruoranthene
lndo
[1^(
3-cd
]pyr
ene
Naph
thal
ene
No
limitap
plie
s
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tapplies
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tapplies
No
limitap
plie
s
No
limi
tap
plie
s
No
limitap
plie
s
No
limi
tapplies
No
limitap
plie
s
No
limi
tapplies
NoOmit
appl
ies
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tap
plie
s
No
limi
tap
plie
s
0.0034
0.0187
0.0186
0.0268
0.5974
0.0065
0.0054
0.006
0.006
0.0055
0.0054
0.0065
0.0060
0.0060
0.0054
0.0053
0.0066
0.0071
0.0048
0.0065
0.5084
07/0809:48-15:57
07/0809:48-15:57
07/0809:48-15:57
07/0809:48-15:57
08/0809:45-15:52
McertsMM03149
McertsMM03149
McertsMM03149
McertsMM03149
McerfsMM03149
0.001
0.0057
0.0056
0.0081
0.1338
[1]The
result
given
isthemaximumvalue(ortheminimumvalue
inthecaseofa
limitth
atisexpressedasaminimum)obtainedduringthereportingpe
riod
,
expressed
inthesametermsastheemission
limi
tvalue.Wheretheemission
limitvalue
isexpressedasarange,there
sult
isgivenasthe'minimum-
maximum'measuredvalues.
[2]Whereanintemationally
recognisedstandardte
stmethod
isusedthereferencenumber
isgiven.Whereanothermethodth
athasbeenformallyagreed
with
theAgency
isused,thentheappropriate
identifier
isgiven.
Inothercasestheprincipaltechnique
isst
ated
,e.
g.gaschromatography.
[3] For non-continuous measurements the date and time of the sample that produced the result is given. For continuous measurements the percentage of theprocess operating time covered by the result is given.
[4] The accreditation status of the equipment and/or the monitoring organisation, as appropriate, for the methods used for both sampling and analysis.[5] The uncertainty associated with the quoted result at the 95% confidence interval, unless otherwise stated.[6] The result to be reported as a range based on: All congeners less than the detection limit assumed to be zero as a minimum, and all congeners less thanthe detection limit assumed to be at the detection limit as a maximum-see also reporting form A9.
Signedo