WALKair V3.1
UMN: OPAM
Terminal Station Management Guide
P/N 110504-02 D Rev 1.0
January 2000
8/10/2019 OPAM-Terminal Station Management Guide
2/74
8/10/2019 OPAM-Terminal Station Management Guide
3/74
TABLE OF CONTENTS
P/N 110504-02 D Rev 1.0 Page i
TABLE OF CONTENTS
1 Introduct ion ............................................................................................. 1-1
2 Terminal Station LED Indicator Interface.............................................. 2-12.1 Terminal Station Base Unit LEDs................................................. 2-1
3 Terminal Station Local Craft Interface .................................................. 3-13.1 Global Navigation Key Symbol Commands.................................. 3-1
4 Configuring the TS.................................................................................. 4-1
5 Radio Link Parameters Menu ................................................................. 5-35.1 Determining the Cable Length...................................................... 5-55.2 Setting the Cable Length.............................................................. 5-65.3 Determining the Cable Type......................................................... 5-75.4 Setting the Cable Type................................................................. 5-85.5 Displaying the Gain Table for Other Cable Types...................... 5-95.6 Setting the Gain Table for Other Cable Types ......................... 5-105.7 Getting the RFU Head Type....................................................... 5-115.8 Setting the RFU Head Type ....................................................... 5-115.9 Getting the Modem Working Point.............................................. 5-12
5.10 Setting the Modem Working Point.............................................. 5-136 Administ rative Parameters Menu .......................................................... 6-1
6.1 Getting the TS Serial Number ...................................................... 6-26.2 Getting the TS Administrative Status............................................ 6-36.3 Setting the TS Administrative Status............................................ 6-46.4 Getting the TS Customer ID ......................................................... 6-56.5 Setting the TS Customer ID ......................................................... 6-66.6 Getting the System Time.............................................................. 6-76.7 Setting the System Time .............................................................. 6-86.8 Remote CPE Management .......................................................... 6-9
6.8.1 Configuration..........................................................................6-106.8.2 Activation ...............................................................................6-116.8.3 Remote Session.....................................................................6-116.8.4 CPE Alarms ...........................................................................6-11
7 Telecom Interface Parameters Menu................................................... 7-137.1 Getting the TS Telecom Configuration Parameters.................... 7-14
8 Maintaining the TS .................................................................................. 8-1
9 System Tests Menu ................................................................................ 9-39.1 Displaying the Last Reset Cause and Date.................................. 9-49.2 Resetting the System ................................................................... 9-5
9.3 Loop Back Testing........................................................................ 9-69.3.1 Getting TS Loop Backs ........................................................... 9-7
8/10/2019 OPAM-Terminal Station Management Guide
4/74
Chapter 1. Introduction
Page ii P/N 110504-02 D Rev 1.0
9.3.2 Setting TS Loop Backs............................................................ 9-89.4 Telecom Parameters Menu...........................................................9-9
9.4.1 Getting the TS Telecom Configuration Parameters ................. 9-99.4.2 Setting the TS Telecom Configuration Parameters................ 9-109.4.3 Setting the TS Telecom Admin Status................................... 9-119.4.4 Ending the TS Telecom Test Mode ....................................... 9-12
10 System Alarm and Error Menu ...........................................................10-1310.1 Displaying the Error Log ...........................................................10-1410.2 Toggling Error Messages..........................................................10-1410.3 Displaying Current Active Alarms .............................................10-1510.4 Getting Alarm Display State......................................................10-1610.5 Enabling or Disabling Alarm State ............................................10-16
11 Version Contro l Menu .........................................................................11-1811.1 Getting Version Inofrmation ......................................................11-1911.2 Switching Software Versions ....................................................11-20
12 Air Performance Monitoring ...............................................................12-2112.1 Setting the Report Format ........................................................12-2112.2 Getting the Current Performance Parameters ..........................12-2212.3 Local Measurements ................................................................12-2312.4 Resetting the FER Counters.....................................................12-24
Appendix A IF Index Tables ............ ............. ............. ............ ............. ............ A-1
8/10/2019 OPAM-Terminal Station Management Guide
5/74
LIST OF FIGURES
P/N 110504-02 D Rev 1.0 Page iii
LIST OF FIGURES
Figure 2-1: TS/BU Front Panel LEDs...................................................................... 2-1Figure 3-1: Main Menu............................................................................................ 3-2Figure 4-1: Configuration Menu............................................................................... 4-1Figure 5-1: Radio Link Parameters Menu................................................................ 5-3Figure 8-1: Maintenance Menu Options .................................................................. 8-1Figure 9-1: System Tests Menu .............................................................................. 9-3Figure 9-2: LoopBack Testing ................................................................................. 9-6
LIST OF TABLES
Table 2-1: TS/BU LED Indicators........................................................................... 2-1Table 2-2: LED Color Coding................................................................................ 2-2Table 3-1: Global Navigation Key Symbol Commands........................................... 3-1Table 3-2: LCI Print Levels .................................................................................... 3-2Table 3-3: Main Menu Option Definitions ............................................................... 3-3Table 4-1: Configuration Menu Option Definitions.................................................. 4-1Table 5-1: Radio Link Parameters Menu Option Definitions................................... 5-4Table 6-1: Administrative Parameters Menu Option Definitions ............................. 6-2Table 8-1: Maintenance Menu Option Definitions .................................................. 8-1Table 9-1: System Tests Menu Option Definitions ................................................. 9-4Table 9-2: TS Loop Back Menu definitions ............................................................ 9-7Table 10-1: System Alarm and Error Menu Option Definitions ..............................10-13Table 11-1: Version Menu Option Definitions........................................................11-18Table A-1: IF Index For 3.5 GHz Bands A, B, and C .............................................. A-1Table A-2: IF Index For 10.5 GHZ Band.................................................................A-4Table A-3: IF Index For 26 GHz Band AH ............................................................A-7
8/10/2019 OPAM-Terminal Station Management Guide
6/74
8/10/2019 OPAM-Terminal Station Management Guide
7/74
P/N 110504-02 D Rev 1.0 Page 1-1
1 INTRODUCTION
The Terminal Station Management Guide explains the operation of the TSembedded software. It is assumed that a Local Craft has already beenconnected to the TS according to the instructions provided in the TerminalStation Commissioning Guide.
8/10/2019 OPAM-Terminal Station Management Guide
8/74
8/10/2019 OPAM-Terminal Station Management Guide
9/74
P/N 110504-02 D Rev 1.0 Page 2-12-12-1
2 T ERMINAL S TATION LED I NDICATOR
INTERFACEThe operator can monitor the system and equipment status by observingthe LED indicators or the LCI terminal.
2.1 Terminal Station Base Unit LEDsThe LEDs provide visual indication of the functioning equipment and reportthe existence of system and equipment alarms. Figure 2-1 illustrates theTS/BU front panel LEDs. Table 2-1 and Table 2-2 details the LEDindicators and LED Color Coding.
F IGURE 2-1: TS/BU F RONT P ANEL LED S
Tx
LED Status Indicators
TX TX RXRX
INT EXT
T ABLE 2-1: TS/BU LED I NDICATORS
LED DESCRIPTION
EXT(Outdoor)
Indicates the status of the outdoor equipment and radio link (e.g., failure inthe RFU or a lost connection with one of the TSs).
INT(Indoor)
Indicates the status of the indoor equipment.
Telecom Indicates the status of the specificTelecom Interface.
8/10/2019 OPAM-Terminal Station Management Guide
10/74
Chapter 2. Terminal Station LED Indicator Interface
Page 2-2 P/N 110504-02 D Rev 1.0
T ABLE 2-2: LED C OLOR CODING
LED State Internal External CPE Interface
Blinking Red Disable Frequency Search Disable
RED Major Major Major
Blinking Yellow Loop back Loop back Loop back
YELLOW Minor Minor Minor
Blinking Green Software Download
GREEN Serviceable Serviceable Serviceable
8/10/2019 OPAM-Terminal Station Management Guide
11/74
P/N 110504-02 D Rev 1.0 Page 3-13-13-1
3 T ERMINAL S TATION LOCAL CRAFT INTERFACE
3.1 Global Navigation Key Symbol CommandsThe TS software provides several global key symbol commands in order tofacilitate navigation of the Menu Structure as shown in Table 3-1.
Type the then press in order to perform the requestedfunction.
T ABLE 3-1: G LOBAL N AVIGATION KEY S YMBOL COMMANDS
SYMBOLS FUNCTION
* Press * to access the Main (root) menu in the software.From the main menu you access all other LCI functions.^ Press ^ to access the previous menu in the LCI screenin the LCI hierarchy.= Press = anytime to refresh the LCI monitor screen. Thiserases all information that was on the screen and re-displays the
current menu at the top of the screen.
%Press % to toggle the ON/OFF display mode of error
messages should they occur.
+ Press + to advance the print level. The change isdisplayed on the LCI monitor.- Press - to reduce the print level. The change isdisplayed on the LCI monitor.
The LCI reports system alarms and events by displaying messages on theterminal monitor. The type of messages that are printed depends on theset print level.
8/10/2019 OPAM-Terminal Station Management Guide
12/74
Chapter 3. Terminal Station Local Craft Interface
Page 3-2 P/N 110504-02 D Rev 1.0
Table 3-2 describes the print levels in descending order. Each print levelincludes the lower level messages.
T ABLE 3-2: LCI P RINT LEVELS
PRINT LEVEL
Info The default level displays all alarm and event messages,including status message (e.g., scanning frequencies).
Warning Displays alarms that are the Warning Level.
Error Displays alarms that are the Error Level.
Fatal Displays alarms that are the Fatal Level.
Display Displays no alarms or events, only the LCI menus.
None Displays no alarms, events or LCI menus, (displays a blankscreen). If your LCI monitor displays a blank screen, press to reduce to the Display Print Level.
The Main Menu screen (see Figure 3-1) is the root or first level of the TSsoftware. It provides access to the two general-purpose operation sets of the TS as described in Table 3-3.
F IGURE 3-1: M AIN MENU
8/10/2019 OPAM-Terminal Station Management Guide
13/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 3-3
T ABLE 3-3: M AIN MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. ConfigurationMenu
Enables configuration of the Radio LinkParameters, Telecom Interfaces and the
Administrative Parameters of the TS.
2. MaintenanceMenu
Enables the operation and maintenance of the of the WALKair system including the following items:
System Tests
System Alarms
Software Download
8/10/2019 OPAM-Terminal Station Management Guide
14/74
8/10/2019 OPAM-Terminal Station Management Guide
15/74
P/N 110504-02 D Rev 1.0 Page 4-14-14-1
4 C ONFIGURING THE TS
The Configuration Menu is used to configure parameters required for air link establishment. Figure 4-1 displays the Configuration Menu; Table 4-1describes the menu options.
F IGURE 4-1: C ONFIGURATION MENU
T ABLE 4-1: C ONFIGURATION MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. Radio Link ParametersMenu
Enables configuration of the cable type,length and operating frequency.
2. AdministrativeParameters Menu
Enables the TS Parameters for selectedmodules i.e., Serial Number, Customer IDNumber, and System Time.Enables/Disables TS operation.
3. Telecom InterfacesParameters Menu
Enables the physical configuration of Telecom services for E1, V.35/X.21, andFrame Relay.
8/10/2019 OPAM-Terminal Station Management Guide
16/74
Chapter 4. Configuring the TS
Page 4-2 P/N 110504-02 D Rev 1.0
8/10/2019 OPAM-Terminal Station Management Guide
17/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 5-3
5 R ADIO LINK P ARAMETERS MENU
Figure 5-1 displays the Radio Parameters submenu. Table 5-1 describeseach of the menu commands.
F IGURE 5-1: R ADIO LINK P ARAMETERS MENU
8/10/2019 OPAM-Terminal Station Management Guide
18/74
Chapter 5. Radio Link Parameters Menu
Page 5-4 P/N 110504-02 D Rev 1.0
T ABLE 5-1: R ADIO LINK P ARAMETERS MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
0. Get Cable Length Displays the IF cable length in meters.1. Set Cable Length Specifies the IF cable length.
2. Get Cable Type Displays the IF cable type.
3. Set Cable Type Specifies the cable type. Use this option toselect the standard LMR400 cable or other cable.
4. Get other cabletype Gain Table
Displays the other cable gain table.
5. Set other cable
type Gain Table
Specifies the upstream and downstream gain
of the cable as per vendor specifications.Must be repeated for all IF frequencies.
6. Get Gain Table Displays the operating cable gain.
7. Set Gain Table Specifies the operating frequency accordingto cable length and type.
8. Get RFU HeadInformation
Displays the operating RFU Head Type.
9. Set RFU HeadInformation
Specifies the operating RFU Head Type.
A. Get ModemWorking Point Displays the working parameters of themodem.
B. Set ModemWorking Point
Specifies the working parameters of theModem. Used for fine tuning the Modem.
8/10/2019 OPAM-Terminal Station Management Guide
19/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 5-5
5.1 Determining the Cable LengthTo Display the Cable Length :1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option number 0 thenpress .The Get Cable Length menu displays the current cable length.
8/10/2019 OPAM-Terminal Station Management Guide
20/74
Chapter 5. Radio Link Parameters Menu
Page 5-6 P/N 110504-02 D Rev 1.0
5.2 Setting the Cable LengthCable length is used for computing IF cable attenuation based on apredefined cable type (see Setting Cable Type para. 5.4) .
When setting cable lengths, a whole number must be used. The number represents the cable length in meters.
To Set the Cable Length :1. From the Main Menu, select option number one then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number one then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option number 1 thenpress .The TS Cable Length parameter input is displayed.
4. Specify the Cable Length then press .
8/10/2019 OPAM-Terminal Station Management Guide
21/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 5-7
NOTE
All gain settings for cables other than the standard LMR400 andCF CU2Y 50 Ohm cables must be set to specifications supplied by thevendor.
5.3 Determining the Cable TypeTo Display the Cable Type:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.
2. From the Configuration Menu, select option number 1 then press.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option number 2 thenPress .The TS Cable Type menu displays the current Cable Type.
8/10/2019 OPAM-Terminal Station Management Guide
22/74
Chapter 5. Radio Link Parameters Menu
Page 5-8 P/N 110504-02 D Rev 1.0
5.4 Setting the Cable TypeUse this option to select the cable type. The system has built in gain tablesfor the LMR400 and the CF CU2Y 50 Ohm cable types. If Other CableTypes is selected, then the Gain Table must be inserted.
To Set the Cable Type:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option number 3 thenpress .The Cable Type parameter input is displayed.
4. Type L to select the standard LMR400 cable then press .5. Type C to select the CF CU2Y 50 Ohm cable, then press .6. Type O then press to specify another cable classification.
8/10/2019 OPAM-Terminal Station Management Guide
23/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 5-9
5.5 Displaying the Gain Table for Other CableTypes
To Determine Other Cable Types :1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option number 4 thenpress .The Other Cable Types Frequency Cable Gain table is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
24/74
8/10/2019 OPAM-Terminal Station Management Guide
25/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 5-11
NOTE
All gain settings for cables other than LMR400 and CF CU2Y S\50 ohmmust be set according to vendor specifications.
5.7 Gett ing the RFU Head TypeTo Get the RFU Head Type:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option number 8 thenpress .The following is displayed.
5.8 Sett ing the RFU Head TypeTo Set the RFU Head Type:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
26/74
Chapter 5. Radio Link Parameters Menu
Page 5-12 P/N 110504-02 D Rev 1.0
3. From the Radio Link Parameters Menu, select option number 9 thenpress .The following is displayed.
4. Select the appropriate RFU head type for either 3.5 GHZ, 10.5 GHz or 26 GHz then press .
5.9 Getting the Modem Working PointTo Access the Modem Working Point1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option A then press.The Modem Working Point Parameters is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
27/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 5-13
5.10 Setting the Modem Working PointModem configuration enables optimizing modem performance betweenthe BS and TS. Typically, the default settings are used however; it ispossible to configure the Modem Working point in order to control cell size.
When setting the Modem Working Point, select either the default values or enter the Nominal Power values for Tx and Rx.
To Set the Modem Working Point :1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 1 then press
.The Radio Link Parameters Menu is displayed.
3. From the Radio Link Parameters Menu, select option B then press.The Modem Working Point Parameters menu, containing the Currentand Default values, is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
28/74
Chapter 5. Radio Link Parameters Menu
Page 5-14 P/N 110504-02 D Rev 1.0
4. Type Y to select the default values then press .
8/10/2019 OPAM-Terminal Station Management Guide
29/74
P/N 110504-02 D Rev 1.0 Page 6-16-16-1
6 A DMINISTRATIVE P ARAMETERS MENU
The Administrative Parameters Menu enables configuration of the TSsystem settings. Table 6-1 describes the menu item options.
To Access the Administ rative Parameters Menu:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
30/74
Chapter 6. Administrative Parameters Menu
Page 6-2 P/N 110504-02 D Rev 1.0
T ABLE 6-1: A DMINISTRATIVE P ARAMETERS MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. Get TS Serial Number Displays the selected TS serial number in a decimal format.
2. Get TS AdministrativeStatus
Displays the current status of theselected TS (enabled / disabled).
3. Set TS AdministrativeStatus
Defines the selected TS operativestatus (Enabled / Disabled).
4. Get TS Customer ID Displays the TS customer ID number indecimal format.
5. Set TS Customer ID Defines the selected TS customer IDnumber in a decimal format.
6. Get System Time Displays the current date and time of the selected TS.
7. Set System Time Defines the date (dd / MM / yyyy) andtime of the selected TS.
8. Set Serial I/O to CPE Enables remote CPE management viathe RS-232 port of the TS to theRS-232 port of the BS.
9. Set CPE Alarm Prefix Enables the TS to recognize the Alarmand send it to the BS as a WALKair
Trap.
6.1 Getting the TS Serial Number To Get the TS Serial Number:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.
2. From the Configuration Menu, select option number 2 then press.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 1 thenpress .The TS serial number is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
31/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 6-3
6.2 Getting the TS Administrative StatusTo Get the TS Administration Status:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 2 thenpress .The Administrative status of the TS is displayed (Enabled / Disabled).
8/10/2019 OPAM-Terminal Station Management Guide
32/74
8/10/2019 OPAM-Terminal Station Management Guide
33/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 6-5
4. Type E then press to enable the TS.The menu displays ENABLE.
5. Type D then press to disable the TS.The menu displays DISABLE.
6.4 Getting the TS Customer IDTo Get the Customer ID Number:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 4 thenpress .The Customer ID number is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
34/74
Chapter 6. Administrative Parameters Menu
Page 6-6 P/N 110504-02 D Rev 1.0
6.5 Setting the TS Customer IDTo Set the Customer ID Number:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 5 thenpress .The Customer ID input parameter menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
35/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 6-7
4. TS Customer ID number then press .This must be an 8 digit decimal number, from 0 9.
6.6 Getting the System Time
NOTE
The following options are for the time and date of the LCI program. Theseoptions control the time and date stamps that the LCI places on reportedevents and alarms. They are not relevant for the time and date of thenetwork elements.
To Get the System Time:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 6 thenpress .The system time is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
36/74
Chapter 6. Administrative Parameters Menu
Page 6-8 P/N 110504-02 D Rev 1.0
6.7 Setting the System TimeThe TS system clock is a 24-hour clock that can be configured for hours(hh) and minutes (mm). In addition, the TS system clock can be configuredfor the day (dd), month (MM) and year (yyyy). Numbers can be set withleading zeros for single-digit days, years or months. Leading zeros for single-digit time divisions can also be used.
To Set the System Time:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 7 thenpress .The System Time input parameter is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
37/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 6-9
4. Enter the day then press .5. Enter the month then press .6. Enter the year then press .7. Enter the hour then press .8. Enter the minute then press .
6.8 Remote CPE Management
The remote CPE function is required for handling external customer premises equipment that do not support an NMS capability but areequipped with an RS-232 interface for management.
The remote CPE function enables the LCI user at the BS-BU to gainaccess and control over an external device connected to one of itsTS-BU(s) as if the user is operating directly through its terminal.
WALKair acts as a transparent pipe and delivers commands and responseinformation from the user at the BS-BU to the external equipment andbackwards with no interference in the data itself. In addition, all alarms of
the external device are reported to the BS-BU and handed to the NMS(when installed) via a trap report. This function is active whether or not theremote CPE is initiated.
8/10/2019 OPAM-Terminal Station Management Guide
38/74
Chapter 6. Administrative Parameters Menu
Page 6-10 P/N 110504-02 D Rev 1.0
6.8.1 Configuration
The customer equipment is connected to the TS using the serial LCI portof the TS and an RS-232 protocol. When connecting an external devicethe user must configure the serial I/O port of the TS using the LCIMaintenance Menu. When a CPE is connected to the TS the TS LCImenus are accessible using the remote LCI.
To Set the Serial I/O to the CPE:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
3. From the Administrative Parameters Menu, select option number 8 thenpress .The I/O Serial Port to CPE input parameter is displayed.
4. Enter Y to confirm serial connection then press .5. Enter the I/O serial port to be used for remote connection then press
.
8/10/2019 OPAM-Terminal Station Management Guide
39/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 6-11
6.8.2 Activation
The activation of control over a TS CPE is performed from all the BS LCImenus using the following command:
#CPETS.
If the process to gain control fails, then the following message is displayed:CPE Remote Control failed:.
When configured to the CPE all WALKair displays are suppressed.
6.8.3 Remote Session
When the BS remotely controls a TS CPE the BS LCI displays allmessages sent by TS CPE operation. Each line sent from the remotelycontrolled TS CPE is displayed at the BS LCI.
6.8.3.1 Regain Control
Regaining control over the TS serial I/O port is achieved by typing from theBS-BU LCI the following string:#LCI# .
6.8.4 CPE Alarms
Regardless of the remote CPE operation, all CPE alarms that begin with apre-defined prefix are locally terminated by the TS-BU and are reported tothe BS-BU and then to the NMS via a trap report.
The CPE alarms are also displayed on the LCI with the following prefix:CPE TS#.
NOTE:
The identifying prefix may be changed using the LCI Maintenance Menuoption.
To Set the CPE Alarm Prefix:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press
.The Administrative Parameters Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
40/74
Chapter 6. Administrative Parameters Menu
Page 6-12 P/N 110504-02 D Rev 1.0
3. From the Administrative Parameters Menu, select option number 9 thenpress .The CPE Alarm Prefix input parameter is displayed.
4. Enter up to 10 characters CPE Alarm Prefix then press .
8/10/2019 OPAM-Terminal Station Management Guide
41/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 7-13
7 T ELECOM INTERFACE P ARAMETERS MENU
The TS Telecom Parameters are for viewing purposes and can only beconfigured by the BS-BU. The displayed parameters for the TelecomInterface will vary depending on the type of Telecom card installed oneach port.
To Access the TS Telecom Interface Parameters Menu:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed2. From the Configuration Menu, select option number 3 then press
.The Telecom Interface Parameters Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
42/74
Chapter 7. Telecom Interface Parameters Menu
Page 7-14 P/N 110504-02 D Rev 1.0
7.1 Getting the TS Telecom Configuration
ParametersTo Get the TS theTelecom Conf igur ation Parameters:1. From the Main Menu, select option number 1 then press .
The Configuration Menu is displayed.2. From the Configuration Menu, select option number 3 then press
.The Telecom Interface Parameters Menu is displayed.
3. From the TS Telecom Parameters Menu, select option number 1 thenpress .
4. Enter the TS port number (0, 1, 2) to display the Telecom Parametersfor the specified TS port.ORSelect option A to view the TS Telecom Parameters for all ports thenpress .The Get Telecom Configuration Menu is displayed with theconfiguration parameters for all ports.
8/10/2019 OPAM-Terminal Station Management Guide
43/74
P/N 110504-02 D Rev 1.0 Page 8-18-18-1
8 M AINTAINING THE TS
The Maintenance Menu is the second option available form the TS MainMenu as shown in Figure 3-1; Table 8-1 describes the menu item options.
F IGURE 8-1: M AINTENANCE MENU OPTIONS
T ABLE 8-1: M AINTENANCE MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. System Tests Menu Defines loop back testing and displays theresults for the following:
Local TS module
Remote Station Payload
2. System Alarm andError Menu
Displays the current active alarms of thesystem and provides an historical record of all system errors.
3. Version Control Menu Displays current active software informationand enables loading of the new versions of thesoftware.
8/10/2019 OPAM-Terminal Station Management Guide
44/74
Chapter 8. Maintaining the TS
Page 8-2 P/N 110504-02 D Rev 1.0
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
4. Air PerformanceMonitoring Menu
Provides real time Performance Monitoring of the system for reports upon request. Theinformation is obtained from the internalstorage parameters and is updated in I sec. or 15 min intervals.
5. Modem Menu Enables setting the modem to test mode inorder to compute the IF cable attenuation.
8/10/2019 OPAM-Terminal Station Management Guide
45/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 9-3
9 S YSTEM TESTS MENU
The System Test Menu displays the reasons the system was last reset.Included in the display are the causes, date and time of the occurrence. Inaddition, the System Test Menu also enables resetting of the system whenrequired. TS loop back testing options are supported via the System TestMenu as well as testing of the Telecom Parameters for E1 and V.35 /X.21.
Figure 9-1 displays the System Test Menu; Table 9-1 describes the menuitem options.
F IGURE 9-1: S YSTEM TESTS MENU
8/10/2019 OPAM-Terminal Station Management Guide
46/74
Chapter 9. System Tests Menu
Page 9-4 P/N 110504-02 D Rev 1.0
T ABLE 9-1: S YSTEM TESTS MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. Display Last ResetData Cause
Displays the last reset details.
2. System Reset Resets the system .3. LoopBack Menu Defines loop back testing and displays the
results for the following::
Single channel Local TS module Remote station Payload
4. Telecom ParametersMenu
Displays the Telecom parameters for individual or all TSs.
9.1 Displaying the Last Reset Cause and DateTo Display the Last Reset Cause and Date:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
.The System Test Menu is displayed.
3. From the System Tests Menu, select option number 1 then press.The following screen is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
47/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 9-5
The system records the causes for each reset as one of the following: First Reset - the first reset is done after the commissioning process. Unknown - The cause for reset is unknown.
CPU Overload Internal timing problem. Task Request the LCI software initiated the reset for internal
reasons. User Request the operator initiated reset command.
9.2 Resetting the SystemTo Reset the System:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
.The System Test Menu is displayed.
3. From the System Tests Menu, select option number 2 then press.The following screen is displayed.
4. Type Y to reset the system then press .The system is reset.
Af ter r eset the system i ni ti alizes the boo t up sequence.
8/10/2019 OPAM-Terminal Station Management Guide
48/74
Chapter 9. System Tests Menu
Page 9-6 P/N 110504-02 D Rev 1.0
9.3 Loop Back TestingThe following are descriptions of the types of loop back testing supportedby WALKair. Local (L) loop back
Local loop back disconnects the RX lines from the receiver. The dataprovided by the system interface is routed through the analog receiver back to the system interface. This test is used to check the FALC.
Remote (R) loop backIn remote loop back testing, the clock and data recovered from the lineinputs are routed back to the line outputs via the analog or digitaltransmitter. This loop back is used for remote self-testing.
Payload (P) loop backPayload loop back loops the data stream from the receiver sectionback to the transmitter section. The looped data passes the completereceiver including the wander and jitter compensation in the receiveelastic store.
F IGURE 9-2: L OOP B ACK TESTING
Network
Network
Remote loop
Payload loop
local loopLSDI
LSDI
LSDI
BU (BS or TS)
TAFFIFO
FIFO
FIFO
Port
Port
Port
8/10/2019 OPAM-Terminal Station Management Guide
49/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 9-7
Table 9-2 describes the LoopBack Menu options.
T ABLE 9-2: TS L OOP B ACK MENU DEFINITIONS
OPTION
NUMBER
MENU ITEM FUNCTION DESCRIPTION
1. Get TS LoopBack Displays the type of loop back testingcurrently entered into the system for thespecified TS port.
2. Set TS LoopBack Specifies TS Testing for one of thefollowing:
Local
Remote
Payload
9.3.1 Getting TS Loop Backs
To Get TS Loop Backs:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
.The System Test Menu is displayed.3. From the System Tests Menu, select option number 3 then press
.The LoopBack Menu displayed.
4. From the LoopBack Menu, select option number 1 then press .The following menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
50/74
8/10/2019 OPAM-Terminal Station Management Guide
51/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 9-9
6. Enter the type of loop back test for the specified port (s) then press. For example, type option R to set a Remote loop backtest.
7. Use the None option to cancel Loop back testing.
9.4 Telecom Parameters Menu1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
.The System Test Menu is displayed.
3. From the System Tests Menu, select option number 4 then press.The Telecom Parameters Menu displayed.
9.4.1 Getting the TS Telecom Configuration Parameters
To Get the TS theTelecom Configuration Parameters:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
.The System Test Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
52/74
Chapter 9. System Tests Menu
Page 9-10 P/N 110504-02 D Rev 1.0
3. From the System Test Menu, select option number 4 then press.The Telecom Parameters menu is displayed.
4. From the Telecom Parameters, select option number 1 then press.The following screen is displayed.
9.4.2 Setting the TS Telecom Configuration Parameters
To Set the TS theTelecom Conf igur ation Parameters:
1. From the Main Menu, select option number 2 then press .The Maintenance Menu is displayed.
2. From the Maintenance Menu, select option number 1 then press. The System Test Menu is displayed.
3. From the System Test Menu, select option number 4 then press.The Telecom Parameters menu is displayed.
4. From the Telecom Parameters, select option number 2 then press.
The following input screen is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
53/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 9-11
5. Enter the TS port number then press .6. Enter the Card Type then press .7. Enter the Configuration for type V.35/X.21 then press .8. Enter the Data Rate then press .
9. Enter the Protocol then press .10. Enter the Operating Mode then press .11. Enter the TxData Clock then press .12. Enter the Clock Mode then press .13. Enter the Rx Clock Mode then press .14. If screen displays Update OK, then enter Y and press .
The Port Configuration is complete.
9.4.3 Setting the TS Telecom Admin Status
To Set the TS theTelecom Admin Status:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
. The System Test Menu is displayed.
3. From the System Test Menu, select option number 4 then press.The Telecom Parameters menu is displayed.
4. From the Telecom Parameters, select option number 3 then press.
8/10/2019 OPAM-Terminal Station Management Guide
54/74
Chapter 9. System Tests Menu
Page 9-12 P/N 110504-02 D Rev 1.0
5. Type E then press to enable the Telecom Port.ORType D then press to disable the Telecom Port.
9.4.4 Ending the TS Telecom Test Mode
To End the TS theTelecom Port Configuration:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 1 then press
. The System Test Menu is displayed.
3. From the System Test Menu, select option number 4 then press
.The Telecom Parameters menu is displayed.4. From the Telecom Parameters, select option number 4 then press
.The following screen is displayed.
5. Enter the TS port number then press .6. Enter Y then press .
The Test Mode is complete.
8/10/2019 OPAM-Terminal Station Management Guide
55/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 10-13
10 S YSTEM A LARM AND ERROR MENU
The System Alarm and Error Menu allows the display of Toggle Error Messages and Current Active Alarms as well as setting the Alarm DisplayState. Table 10-1 describes the menu item options.
The alarm status of any number of enabled TSs can be verified using thefollowing menu options.
T ABLE 10-1: S YSTEM A LARM AND ERROR MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. Display Error Log Provides an historical record of errors.
2. Toggle Error MessagesDisplay
Enables / disables error message datadisplay.
3. Display Current Active Alarms
Displays the current active alarms.
4. Get Alarms Display State Displays the alarm display status,(enabled / disabled) of the specified TS.
5. Set Alarms Display State Enables / disables the TS alarm display.
To Access the System Alarms and Errors Menu:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 2 then press
.The System Alarms and Errors Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
56/74
Chapter 10. System Alarm and Error Menu
Page 10-14 P/N 110504-02 D Rev 1.0
10.1 Displaying the Error LogTo Display the Error Log:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 2 then press
.The System Alarms and Errors Menu is displayed.
3. From the System Alarms and Errors Menu, select option number 1 thenpress to view the current alarms in the system.
NOTE
Option 1 (Display Error Log) is int ended for use by service personnel.It displays event logs of the last 100 sof tware messages.
10.2 Toggl ing Error MessagesTo Toggle Error Messages:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 2 then press
.The System Alarms and Errors Menu is displayed.
3. From the Systems Alarm and Error Menu, select option number 2 thenpress .The display state of the Error Messages toggles.
8/10/2019 OPAM-Terminal Station Management Guide
57/74
8/10/2019 OPAM-Terminal Station Management Guide
58/74
Chapter 10. System Alarm and Error Menu
Page 10-16 P/N 110504-02 D Rev 1.0
10.4 Getting Alarm Display StateTo Get Alarm Display State1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 2 then press
.The System Alarms and Errors Menu is displayed.
3. From the Systems Alarms and Errors Menu, select option number 4then press .The Alarm Display State is indicated.
10.5 Enabling or Disabling Alarm StateTo Enable or Disable the Alarm State:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 2 then press
.The System Alarms and Errors Menu is displayed.
3. From the Alarms and Errors Menu, select option number 5 then press.The Alarm Display State Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
59/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 10-17
4. Type E then press .The alarm display is enabled.
5. Type D then press .The alarm display is disabled.
8/10/2019 OPAM-Terminal Station Management Guide
60/74
Chapter 11. Version Control Menu
Page 11-18 P/N 110504-02 D Rev 1.0
11 V ERSION CONTROL MENU
Table 11-1 describes the Version Menu item options.
T ABLE 11-1: V ERSION MENU OPTION DEFINITIONS
OPTIONNUMBER
MENU ITEM FUNCTION DESCRIPTION
1. Get Version Information Details the current selected softwarespecifications for all TS/BU componentsincluding:
Version name Source path and date Version number CRC number Program size Date of installation
2. Get Download Status Displays the current status during thesoftware download session.
3. Switch Loaded Version Enables loading of the current or backupversions of the software.
To Access the Version Menu:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 3 then press
.The Version Menu is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
61/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 11-19
11.1 Getting Version InformationTo Get Version Info rmation:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 3 then press
.The Version Menu is displayed.
3. From the Version Menu, select option number 1 then press .The following screen is displayed.
3. To display the current software version information, select option C thenpress .The following screen is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
62/74
Chapter 11. Version Control Menu
Page 11-20 P/N 110504-02 D Rev 1.0
11.2 Switching Software VersionsTo Switch Software Versions:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 3 then press
.The Version Menu is displayed.
3. From the Version Menu, select option number 3 then press .The following screen is displayed.
4. Type Y to confirm software version switch then press New version will be activated after Reset
8/10/2019 OPAM-Terminal Station Management Guide
63/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 12-21
12 A IR P ERFORMANCE MONITORING
The Display Format enables control of the data format for viewing of therecord accumulated in the internal storage of the TS. You can choose todisplay Air Performance Monitoring in three ways: Regular
Displays the actual name of the accumulator, Performance MonitoringParameters and value in number format. Used to monitor TS power performance.
ExcelDisplays the same data as Regular format but separated by comas for
use with a separate application dedicated for viewing the PerformanceMonitoring Parameters. Suitable for display of the data in graphformat.
HexThe Hex option is connected to a separate utility for use by servicepersonnel.
12.1 Setting the Report FormatTo Set the Report Format:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 4 then press
.The Air Performance Monitoring Menu is displayed.
3. From the Air Performance Monitoring Menu, select option number 1then press .The following screen is displayed.
8/10/2019 OPAM-Terminal Station Management Guide
64/74
Chapter 12. Air Performance Monitoring
Page 12-22 P/N 110504-02 D Rev 1.0
4. Type in the first letter of the required display option then press .The selected display option is enabled.
12.2 Getting the Current Performance ParametersThe tables displayed in the Get Current PM Status menu show the type of reports currently available. The system automatically generates the reportfor 1 sec and for 15 min. of the actual number of TSs. If active, the reportlists the TS serial number, Customer ID, and whether the TS is operatingin the following modes: Local Remote / Local Remote Not Active
To Get t he Current PM Status:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 4 then press
.The Air Performance Monitoring Menu is displayed.
3. From the Air Performance Monitoring Menu, select option number 2then press .The following screen is displayed.
Local Measurements provide display reporting options for 1 sec., and15 min. as well as the ability to view and enable or disable the currenttime reporting measurement.
8/10/2019 OPAM-Terminal Station Management Guide
65/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page 12-23
12.3 Local MeasurementsTo Access Local Measurements:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 4 then press
.The Air Performance Monitoring Menu is displayed.
3. From the Air Performance Monitoring Menu, select option number 3then press .
4. Enter the TS serial number then press .The Report Frequency and Report States are displayed.
5. Enter the Report Frequency then press .6. Type E to Enable the Report State.7. Type D to Disable the Report State.
8/10/2019 OPAM-Terminal Station Management Guide
66/74
Chapter 12. Air Performance Monitoring
Page 12-24 P/N 110504-02 D Rev 1.0
12.4 Resett ing the FER CountersThe FER Counter is calculated by dividing the Error Frame by the Actual
Air Frame and is used by Service Personnel to determine any error correction on a TS. Resetting the FER Counter to zero helps the ServicePersonnel better determine if an error effecting the operation of the TSwas corrected.
To Reset the FER Counters:1. From the Main Menu, select option number 2 then press .
The Maintenance Menu is displayed.2. From the Maintenance Menu, select option number 4 then press
.The Air Performance Monitoring Menu is displayed.
3. From the Air Performance Monitoring Menu, Select option number 4then press .The following screen is displayed.
4. Type Y to reset the FER Counter then press .5. Enter the serial number for the TS FER Counter being reset.
8/10/2019 OPAM-Terminal Station Management Guide
67/74
P/N 110504-02 D Rev 1.0 Page A-1 A-1A-1
Appendix A
IF INDEX T ABLEST ABLE A-1: IF I NDEX FOR 3.5 GH Z B ANDS A, B , AND C
TS IF 3.5 GHZ BAND A
IF INDEX TX IF ( INTERMEDIATE FREQUENCY)
F 0 999.25
F 1 1001.00
F 2 1002.75
F 3 1004.50
F 4 1006.25
F 5 1008.00
F 6 1009.75
F 7 1011.50
F 8 1013.25
F 9 1015.00
F 10 1016.75
F 11 1018.50F 12 1020.25
F 13 1022.00
F 14 1023.75
F 15 1025.50
F 16 1027.25
F 17 1029.00
F 18 1030.75
F 19 1032.50
F 20 1034.25
F 21 1036.00
8/10/2019 OPAM-Terminal Station Management Guide
68/74
8/10/2019 OPAM-Terminal Station Management Guide
69/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page A-3
TS IF 3.5 GHZ BAND C
IF INDEX TX IF (INTERMEDIATE FREQUENCY)
F 42 1072.75
F 43 1074.50
F 44 1076.25
F 45 1078.00
F 46 1079.75
F 47 1081.50
F 48 1083.25
F 49 1085.00
F 50 1086.75F 51 1088.50
F 52 1090.25
F 53 1092.00
F 54 1093.75
F 55 1095.50
F 56 1097.25
F 57 1099.00
F 58 1100.75F 59 1102.50
F 60 1104.25
F 61 1106.00
F 62 1107.75
F 63 1109.50
8/10/2019 OPAM-Terminal Station Management Guide
70/74
Chapter 12. Air Performance Monitoring
Page A-4 P/N 110504-02 D Rev 1.0
T ABLE A-2: IF I NDEX FOR 10.5 GHZ B AND
TS IF 10.5 GHZ BAND
IF INDEX TX IF (INTERMEDIATE FREQUENCY)
F 0 1002.00
F 1 1003.75
F 2 1005.50
F 3 1007.25
F 4 1009.00
F 5 1010.75
F 6 1012.50
F 7 1014.25F 8 1016.00
F 9 1017.75
F 10 1019.50
F 11 1021.25
F 12 1023.00
F 13 1024.75
F 14 1026.50
F 15 1028.25F 16 1030.00
F 17 1031.75
F 18 1033.50
F 19 1035.25
F 20 1037.00
F 21 1038.75
F 22 1040.50
F 23 1042.25
F 24 1044.00
F 25 1045.75
F 26 1047.50
F 27 1049.25
F 28 1051.00
F 29 1052.75
F 30 1054.50F 31 1056.25
8/10/2019 OPAM-Terminal Station Management Guide
71/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page A-5
TS IF 10.5 GHZ BAND
IF INDEX TX IF (INTERMEDIATE FREQUENCY)
F 32 1058.00
F 33 1059.75
F 34 1061.50
F 35 1063.25
F 36 1065.00
F 37 1066.75
F 38 1068.50
F 39 1070.25
F 40 1072.00F 41 1073.75
F 42 1075.50
F 43 1077.25
F 44 1079.00
F 45 1080.75
F 46 1082.50
F 47 1084.25
F 48 1086.00F 49 1087.75
F 50 1089.50
F 51 1091.25
F 52 1093.00
F 53 1094.75
F 54 1096.50
F 55 1098.25
F 56 1100.00
F 57 1101.75
F 58 1103.50
F 59 1105.25
F 60 1107.00
F 61 1108.75
F 62 1110.50
F 63 1112.25F 64 1114.00
8/10/2019 OPAM-Terminal Station Management Guide
72/74
Chapter 12. Air Performance Monitoring
Page A-6 P/N 110504-02 D Rev 1.0
TS IF 10.5 GHZ BAND
IF INDEX TX IF (INTERMEDIATE FREQUENCY)
F 65 1115.75
F 66 1117.50
F 67 1119.25
F 68 1121.00
F 69 1122.75
F 70 1124.50
F 71 1126.25
F 72 1128.00
F 73 1129.75F 74 1131.50
F 75 1133.25
F 76 1135.00
F 77 1136.75
F 78 1138.50
F 79 1140.25
F 80 1142.00
F 81 1143.75F 82 1145.50
F 83 1147.25
F 84 1149.00
8/10/2019 OPAM-Terminal Station Management Guide
73/74
WALKair V3.1 UMN: OPAM Terminal Station Management Guide
P/N 110504-02 D Rev 1.0 Page A-7
T ABLE A-3: IF I NDEX FOR 26 GH Z B AND AH
TS IF 26 GHZ BAND AH
IF INDEX TX IF (INTERMEDIATE FREQUENCY)
F0 1701.875
F1 1703.625
F2 1705.375
F3 1707.125
F4 1708.875
F5 1710.625
F6 1712.375
F7 1714.125F8 1715.875
F9 1717.625
F10 1719.375
F11 1721.125
F12 1722.875
F13 1724.625
F14 1726.375
F15 1728.125F16 1729.875
F17 1731.625
F18 1733.375
F19 1735.125
F20 1736.875
F21 1738.625
F22 1740.375
F23 1742.125
F24 1743.875
F25 1745.625
F26 1747.375
F27 1749.125
F28 1750.875
F29 1752.625
F30 1754.375F31 1756.125