Page 1 of 2 SUBMITTAL AVXWVH020CE - Samsung …€¦ · Page 1 of 2 SUBMITTAL Cooling (Btu/h)...

Post on 06-Aug-2018

215 views 0 download

transcript

Page 1 of 2

SUBMITTAL

Cooling (Btu/h)

Heating (Btu/h)

Model

Type

Output (W)

Sound Level

Single Unit EEV Kit MEV-A13SAAccessories

AVXWVH020CE

Condensate Pump ASP-MO-230

Safety Certifications ETL & ETLc

11 1/4

7 1/2

19

31/21

Vivace High Wall Evaporator (Heat Pump & Heat Recovery Systems)

R410A

Electronic Expansion Valve (external to unit)

1/4"

Refrigerant

Piping Connections (inches)

Unit Dimensions

Weight (lbs.)

PerformanceCapacity

Condensate (pints/hour)

Power

Heating HighAirflow (CFM)

Fan

Type

Depth (inches)

Height (inches)

Specifications

YDK-016S1408-01

Feedback SSR

23

247

258

Cooling High

Motor

1/2"

ID 11/16" Hose

32 1/2

6,000

7,000

2.4

High/Low (Db)

1/208-230/60

0.13

Voltage (ø/V/Hz)

Running Current (amps)

Width (inches)

Control Method

Type

Liquid (flare)

Drain

Suction (flare)

Crossflow

������� ���� ����������� ��� ������� ������ �������� ���� ���� �� ���������

����������������� �������� ��������������� ������!�������� ������������

• Electro-static, washable, silver coated main filter as standard

• Supplemental, replicable, anti-allergy and deodorizing filters as standard

• MPI Generator that eliminates airborne biological contaminants

• Motorized front panel

• Digital status/function display on front panel

ConstructionUL94 V0 chassis with galvanized steel mounting bracket

Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube

Indoor FanIndoor fan is a single, antibacterial crossflow type

Three fan speed settings and auto setting

ControlsThe unit ships with a wireless controller as standard

The unit shall be operated via a wireless or wired remote control with DDC type signal

The unit shall integrate with the Samsung Controls Network Solution

Controls shall integrate with a BMS system

Control wiring shall be 16AWG shielded wire

www.SamsungSystemAC.com

Quietside maintains a policy of ongoing development, specifications are subject to change without notice.

*Nominal cooling capacities are based on: Indoor temperature: 80�F DB, 67�F WB. Outdoor temperature: 95�F DB, 75�F WB.*Nominal heating capacities are based on: Indoor temperature: 70�F DB, 60�F WB. Outdoor temperature: 47�F DB, 43�F WB.

QS-DVM-0312A

SUBMITTAL Vivace High Wall Evaporator (Heat Pump & Heat Recovery Systems)AVXWVH020CE Page 2 of 2

Unit: inches

"""#��������$����!#���%%%&'((&')'*

Ø 2 1/2"

4 3/4" 2 11/16"

1 1/16"1 1/16"

Pipe hole locations for straight-through wall penetrations

5" Minimum5" Minimum

11 1/2" Minimum

Minimum clearances from walls and ceiling

Liquid Pipe ConnectionGas Pipe ConnectionDrain Pipe ConnectionOptional Cabinet Penetration OpeningAir Inlet GrilleAir Outlet Louver

123456

NameNo. DescriptionØ 1/4" FlareØ 1/2" Flare

ID 11/16" Hose---

BOTTOM

FRONT

LEFT RIGHT

BACK

32 1/2"1 3/4"

2 1/4"3 3/8"

2 1/4"5 1/2"

15"

7 1/2"

2 1/4

"

2 1/2

"

1 1/4

"

1 5/8

"

Mounting Bracket