Post on 06-Dec-2015
description
transcript
1 © 2007 NSN Water Wu
Course Content
Parameter Configuration Load ControlCommon Channels & Power ControlAdmission ControlPacket SchedulingHandover Control
2 © 2007 NSN Water Wu
Game rule
No Name Years of RF Experience Years of Nokia Experience (C+D)/2 basic card
1 Thana Rattanapinan 10 5 7.5 7
2 Khai Sim 7 2 4.5 4
3 Phairoch Hutinant 7 2 4.5 4
4 Dennis Chen 2 2 2 1
5 John Hsiao 2 2 2 1
6 Nanox Chen 1 1 1 0
7 Jay Peng 1 1 1 0
8 Tony Huang 1 1 1 0
1 Aaron Pan 10 1 5.5 5
2 River Yu 7 3 5 4
3 Mario Dacanay 7 4 5.5 5
4 James Liu 5 1 3 2
5 Pedro Pan 1 1 1 0
6 IT Liu 3 2 2.5 2
7 Rick Lee 1 1 1 0
8 SL Lee 1 1 1 0
3 © 2007 NSN Water Wu
Illustration on RAN Function
SRNC RelocationHandover Control
RNC
BTS2UE BTS1
RNC
WCDMA WCDMA
Admission ControlCommon Channels & Power Control
Packet Scheduling
Mobility:Handover Control
Usage:Load Control
Packet Scheduling X Pre-emption
SRNC
GSM
4 © 2007 NSN Water Wu
Location of RRM Algorithms
5 © 2007 NSN Water Wu
Logical Structure of the RNC Database Objects
RNC
WBTS
WCEL ADJS
HOPS
ADJG
HOPG
FMCG
ADJI
HOPI
FMCI
FMCS
COCO
• RNC = Radio Network Controller
• WBTS = WCDMA Base Station
• WCEL = WCDMA Cell
• ADJ = Adjacency for WCDMA cell
• ADJS = intra-frequency adjacency
• ADJI = inter-frequency adjacency
• ADJG = inter-system adjacency
• HOP = Handover Path
• HOPS, HOPI, HOPG
• FMC = Frequency Measurement Control
FMCS, FMCI, FMCG
• COCO = Radio Network Connection Configuration
6 © 2007 NSN Water Wu
RNC Object• The logical object of the Radio Network Controller • It can have up to 512 WBTS objects (requires RAS51 RNC)• In the RNC object the following interfaces are defined: Iu-PS, Iu-CS and Iur • The logical object are hierarchically related to each other, therefore it is not
possible to create any other object before RNC creation.
RNCRNC
WBTSWBTS
WCELWCELADJSADJS
HOPSHOPS
ADJG
HOPG
FMCG ADJG
HOPG
FMCG
ADJI
HOPI
FMCI ADJI
HOPI
FMCIFMCI
FMCS
COCOCOCO
7 © 2007 NSN Water Wu
WBTS Object
• The logical object of the WCDMA Base Station (Node B). A WBTS can have up to 24 WCDMA cells and one COCO object.
RNCRNC
WBTSWBTS
WCELWCELADJSADJS
HOPSHOPS
ADJG
HOPG
FMCG ADJG
HOPG
FMCG
ADJI
HOPI
FMCI ADJI
HOPI
FMCIFMCI
FMCS
COCOCOCO
8 © 2007 NSN Water Wu
WCEL object
• The logical object of the WCDMA Cell is created to define the configuration of the WCDMA Node B site. In one RNC database there can be 1152 WCELs.
RNCRNC
WBTSWBTS
WCELWCELADJSADJS
HOPSHOPS
ADJG
HOPG
FMCG ADJG
HOPG
FMCG
ADJI
HOPI
FMCI ADJI
HOPI
FMCIFMCI
FMCS
COCOCOCO
9 © 2007 NSN Water Wu
Handover PathHOPx
• The Handover Path object stores mainly cell reselection and Intra frequency HHO parameters. One Hop can be related to several Adjacency objects.
• The maximum number of HOPx objects within one category is 100.• E.g. for different type of cells (urban, rural, macro/micro/pico)
• HOP Types:
• HOPS — object for intra-frequencyHandover Path
• HOPI — object for inter-frequencyHandover Path
• HOPG — object for inter-systemHandover Path
RNCRNC
WBTSWBTS
WCELWCELADJSADJS
HOPSHOPS
ADJG
HOPG
FMCG ADJG
HOPG
FMCG
ADJI
HOPI
FMCI ADJI
HOPI
FMCIFMCI
FMCS
COCOCOCO
10 © 2007 NSN Water Wu
Adjacencies ADJx
• Adjacencies for WCDMA cell refers to a handover relationship between two cells. They are defined for neighbouring cells.
• Adjacency Types:
• ADJS — object for intra-frequency Adjacency • ADJI — object for inter-frequency Adjacency• ADJG — object for inter-system Adjacency
There can be 31 intra frequency adjacencies (ADJS), 48 inter-frequency adjacencies (ADJI) and 32 inter-system adjacencies (ADJG)
Handover Path objects must be created before ADJx can be used
RNCRNC
WBTSWBTS
WCELWCELADJSADJS
HOPSHOPS
ADJG
HOPG
FMCG ADJG
HOPG
FMCG
ADJI
HOPI
FMCI ADJI
HOPI
FMCIFMCI
FMCS
COCOCOCO
11 © 2007 NSN Water Wu
Frequency Measurement Control
• The FMC object contains information concerning the frequency measurement functionality of the RNC.
• The maximum number of frequency measurement control objects within one category is 100.
• E.g. for different type of cells (urban, rural, macro/micro/pico)
• One FMC can be related to several WCDMA cells.• FMC Types:
• FMCS — object for intra-frequencyFrequency Measurement Control
• FMCI — object for inter-frequencyFrequency Measurement Control
• FMCG — object for inter-systemFrequency Measurement Control
RNCRNC
WBTSWBTS
WCELWCELADJSADJS
HOPSHOPS
ADJG
HOPG
FMCG ADJG
HOPG
FMCG
ADJI
HOPI
FMCI ADJI
HOPI
FMCIFMCI
FMCS
COCOCOCO
12 © 2007 NSN Water Wu
ADJS
ADJS
FMCS(NRT)
FMCS(RT)
HOPS(RT)
HOPS(NRT)
NrtHopsIdentifier = 1
RtHopsIdentifier = 2
HSDPAHopsIdentifier = 6
NrtHopsIdentifier = 1
RtHopsIdentifier = 2
HSDPAHopsIdentifier = 6 HOPSid = 1
HOPSid = 2
FMCSid = 1
FMCSid = 1
ADJSid = 1
ADJSid = 2
WCEL
WCEL
WCELWBTS
Each WCEL has associated 1 FMCS for NRT & 1 for RT & 2 for HSDPA, all can be reused for other cells.
Each ADJS has associated 1 HOPS for NRT & 1 for RT & 1 for HSDPA, sets can be reused for other cells.)
NrtFmcsIdentifier = 3
RtFmcsIdentifier = 40
HSDPAFmcsIdentifier = 50
NrtFmcsIdentifier = 3
RtFmcsIdentifier = 40
HSDPAFmcsIdentifier = 50
Summary
FMCS(HSDPA)
FMCSid = 2
HOPS(HSDPA) HOPSid = 6
HOPS(RT)
HOPS(NRT)
HOPSid = 1
HOPSid = 5
HOPS(HSDPA) HOPSid = 7
FMCS(RT&HSDPA)
FMCSid = 2