Pearce avenue

Post on 12-Jan-2017

282 views 1 download

transcript

_1m _3m _5m _10m0

Lounge

Dining

Media room

Kitchen

Study

Utility room

Vault above

Outside dining

WC

Garage

459.0 6000.0

3431.0

2533.0

838

Doo

r83

8 D

oor

762 Door2063.0

1647.0

SVP

Open up existingcavity and alignafter inspection

Fan outlet 15L/SEXCT FAN

AV Cupb'd St.

BBQ client toconfirm

Fireplace to clientsspecification

SVP

STAIRCASE:Timber:Part K15 Risers =186mm.Goings = 220mm.Pitch = 40°

rwp

659.0

4800.0

300.0

1100.0

1400.0

1100.0

900.0

6233.0

1083.0

2500.0

2500.0

300.0

940.0

407.0

100.0

912.0

347.0

900.0

600.0

2043.0

St. St.

600mm x 600mmPaving slabs

Timber Louvre's -client to confirmspecification

Bedroom

Bedroom

Bedroom

En-Suite

En-suite

Bedroom

Bathroom

12783.0

1200.0 3044.0 2575.0 875.0 2030.0 2159.0 900.0

11581.0

5666.0

1200.0

4715.0

11581.0

6233.0

1200.0

4148.0

12783.0

450.0 3268.0 1594.0 2159.0 2228.0 2159.0 925.0

Insulated cavity closers to allproposed doors and windows .

3655.0

4497.0

1800.0

3618.0

3642.0

4910.0

1900.0

3618.0

3000.0

3641.0

4890.0

2825.0

4448.0

2825.0

2329.0

4293.0

2600.0

2825.0

1200.0

5968.0

1150.0

1171.0

838 Door

838

Doo

r

838

Doo

r

838 Door

FD30 838

FD30 838

FD30

838

838 Door

SVP

SVP

Fan outlet 15L/SEXCT FAN

Fan outlet

15L/SEXCT FAN

TowelRail

Fan outlet

15L/SEXCT FAN

SVP

rwp

838 Door

TowelRail

838 Door protruding lightbox toelectriciansspecification

Velux TWF -Flexible suntunnel

WALL LEGEND

BLOCK AND BEAM'

'Periscopic' type vents to manufacturers details

30mm Finish Render

100mm Concrete Block

50mm Cavity

50mm Celotex

100mm Thermalite Turbo block ( to achieve K value of 0.11)

12.5mm plasterboard on 10mm dabs, taped and skimmed

STUD WORK

70mm Metal Studwork

25MM Wool batts internally (minimum thickness 25MM, Minimum

density 10 KG/M3)

15MM Plasterboard to both sides all joints to be taped and skimed.

Smoke detectorMains powered single station smoke detector units in strict

accordance with BS5446 within hall of house, exact position to be

determined with building inspector on site.

FIRE LEGEND

DRAINAGE.

Rain water pipes

Soil vent pipes

VENTILATION.

Mechanical extract fan ceiling mounted.

SVP

rwp

Heat Detector

VMZ Angle

Profile

38mm Timber

Batten

Breather

Membrane

Breather Membrane

38mm Timber Batten

VMZ Interlocking

Panels

VMZ Fixation Clip

Mesh

Welted Panels VMZinc with

perforated grids

VMZ Profile clip

Mesh

Mastic Sealant

Welted Panels VMZinc with

perforated grids

Soldered clip in VMZINC

BUILDING REGULATIONS

PROPOSED FLOOR PLANS

01202 280638

mail@dotarchitecture.co.uk

www.dotarchitecture.co.uk

as shown

MAY 14

PROPOSED GROUND FLOOR PLANSCALE 1:50@A1

23 Pearce AvenuePoole

BH14 8EG

102631BR

Mr & Mrs. S. Beales

PROPOSED FIRST FLOOR PLANSCALE 1:50@A1

G

All drawings to be read in conjunction withStructural Engineers drawings and calculations

Denotes existing structure

E Amended to clients comments AUG 14F Amended to clients comments SEP 14G Amended to clients comments SEP 14

PROPOSED ANGLE DETAILSCALE 1:10@A1

PROPOSED WINDOW DETAILSCALE 1:10@A1

_1m _3m _5m _10m0

rwp

WALL LEGEND

BLOCK AND BEAM'

'Periscopic' type vents to manufacturers details

30mm Finish Render

100mm Concrete Block

50mm Cavity

50mm Celotex

100mm Thermalite Turbo block ( to achieve K value of 0.11)

12.5mm plasterboard on 10mm dabs, taped and skimmed

STUD WORK

70mm Metal Studwork

25MM Wool batts internally (minimum thickness 25MM, Minimum

density 10 KG/M3)

15MM Plasterboard to both sides all joints to be taped and skimed.

Smoke detectorMains powered single station smoke detector units in strict

accordance with BS5446 within hall of house, exact position to be

determined with building inspector on site.

FIRE LEGEND

DRAINAGE.

Rain water pipes

Soil vent pipes

VENTILATION.

Mechanical extract fan ceiling mounted.

SVP

rwp

Heat Detector

W05 W06

W04

W06

D02D01

W01 W02

W03

SL01 SL01

W02

VMZ Continuous

welt piece

Aluminium Fascia

(to clients specification)

VMZ Fixation Clip

VMZINC Interlocking

Panels

38mm Timber Batten

screwed vertically

to Blockwork

75x75mm Batten screwed

onto vertical batten

White painted render

Existing wall make up

Render bead

Sika Sarnafil Sealant

15mm Ply

VMZINC

Interlocking

Panels

VMZ Continuous

welt piece

Aluminium Fascia

(to clients specification)

15mm Ply

38mm Timber Batten

screwed vertically

to Blockwork

Aluminium Trim

Timber Batten

Timber Joists to structural

engineers design

22mm ply sat on timber firings

Single Ply

Membrane

125mm Insulation on

top of rafters.

Insulation to be fixed

by Mechanical fixings

(U Value 0.16WmĮK)

Existing wall make up

BUILDING REGULATIONS

PROPOSED FLOOR PLANS

01202 280638

mail@dotarchitecture.co.uk

www.dotarchitecture.co.uk

as shown

MAY 14

23 Pearce AvenuePoole

BH14 8EG

103631BR

Mr & Mrs. S. BealesPROPOSED ROOF PLANSCALE 1:50@A1 PROPOSED EAVES DETAIL

SCALE 1:20@A3SCALE 1:10@A1

E

All drawings to be read in conjunction withStructural Engineers drawings and calculations

C Amended to clients comments AUG 14D Amended to clients comments AUG 14

PROPOSED FRONT ELEVATIONSCALE 1:200@A3SCALE 1:100@A1

PROPOSED SIDE ELEVATIONSCALE 1:200@A3SCALE 1:100@A1

E Amended to clients comments SEP 14

PROPOSED CLADDED RAIL DETAILSCALE 1:10@A1PROPOSED ROOF DETAIL TO GARAGE

SCALE 1:10@A1

_1m _3m _5m _10m0

White Render

D04

W07 W08W02

Marley EternitEquitone Pictura

Slate Effect RoofTile

W10

D05

W11

W09

WINDOWS SCHEDULE

ALL WINDOWS TO COMPLY WITHBUILDING REGULATIONS APPROVED DOCUMENT.

SAMPLE TO BE SUBMITTED BY CONTRACTOR FOR CLIENT APPROVALPRIOR TO ORDERING UNITS.

ALL WINDOWS TO HAVE TRICKLE VENTS AND DOUBLE GLAZED UNITS -

ALL WINDOW SIZES TO BE CONFIRMED ON SITE PRIOR TO ORDERS BEING PLACED

MANUFACTURER - TO BE CONFIRMED BY CONTRACTOR/CLIENTMAIN CONTRACTOR TO ALLOW PROVISIONAL SUM FOR THE SUPPLY ANDFITTING OF ALL WINDOW IRONMONGERY.

D01

SL01 SL01D02

W01

W02

W03

W04

W05

W051200mm x 560mm

W06

W061100mm x 560mm

W07

W07875mm x 1800mm

W08

W083044mm x 1800mm

D04 - Sliding6000mm x 2350mm

W09

D05

W08900mm x 1400mm

D04

W10

W11

W10940mm x 600mm

W11900mm x 1000mm

W07 W08W02

150.0

Breather Membrane

Aluminium Coping

VMZ Fixation Clip

38mm Timber Batten

screwed to Blockwork

200mm Ceiling Joists to

structural engineers design

100mm Dense Concrete Block

Lead Work on

top of

15mm Ply Sheathing

VMZINC Interlocking

Panels

ceiling material

to clients specification

VMZ Continuous

welt piece

Breather Membrane

Timber Fillet

75mm Celotex insulation(or equivilant)

10kg Densesound fibre

quilt

Plasterboard finish

BUILDING REGULATIONS

PROPOSED ELEVATIONS

01202 280638

mail@dotarchitecture.co.uk

www.dotarchitecture.co.uk

as shown

MAY 14

23 Pearce AvenuePoole

BH14 8EG

104631BR

Mr & Mrs. S. Beales

PROPOSED REAR ELEVATIONSCALE 1:200@A3SCALE 1:100@A1

PROPOSED SIDE ELEVATIONSCALE 1:100@A1

PROPOSED KEY SECTIONSCALE 1:50@A1

PROPOSED FOUNDATION DETAILSCALE 1:10@A1

PROPOSED FLAT ROOF DETAILSCALE 1:10@A1

F

PROPOSED INTERMEDIATE FLOOR DETAILSCALE 1:10@A1

E Amended to clients comments SEP 14F Amended to clients comments SEP 14