Post on 13-Mar-2016
description
transcript
ProductCatalog
Turnkey systems and solutions for photovoltaic power plants
Our systems and solutions for photovoltaic power plants
General Terms and Conditions
This catalogue is intended as documentation for commercial, residential and industrial users. Our terms of
payment, sales and delivery shall apply.
Our publications are intended to provide information to the best of our knowledge and are in no way intended
to be legally binding.
Illustrations are not binding, especially with regard to colour, size and equipment of the products shown.
Industrial property rights exist for many of the products.
We reserve the right to make technical and formal changes to our products in the interest of technical
progress.
All items in this catalogue which are subject to CE regulations bear the CE mark on their packaging label and
on the product itself.
Dear Customers,
Photovoltaic electricity, once confined to space exploration, has since the beginning of the 21st century,
gained access to the realm of power generation.
The impressive growth of the PV market, mainly driven during those years by the European interest for
this particular technology, has since then led to a major decrease in system prices, bringing PV technology
among the emerging technologies for power generation on a large scale.
At Sat Control we are proud to be one of the first companies worldwide to successfully implement innova-
tive, cost-effective, reliable, robust and active solar tracking systems in the world.
Sat Control accelerates technological innovations by industry led research and development tracking sys-
tems offering outstanding long-term performance. Sat Control provides solutions that demonstrate cost
effectiveness, added value, and go beyond the business. Setting the highest quality standards is Sat Con-
trol’s main objective.
Sat Control products are a result of intensive research and development efforts, manufactured in a state of
the art automated production environment and comply with the principal international standards: Interna-
tional Protection Rating (IEC 60529 IP33), Electromagnetic Compatibility (EMC Directive 89/336/EEC) and
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC).
Components and materials used in production originate from well established suppliers, are pre-certified,
tested and meet the highest quality standards. Due to the strict quality control at each step of the produc-
tion process, Sat Control is able to offer its customers up to 10-year product warranty.
Headquartered in Slovenia, at Sat Control we find our place predominantly in diverse international mar-
kets. Tracker installations of every size have been deployed internationally, including utility-scale projects
in more than 45 countries over the world including Germany, France, Italy, Slovakia, Czech Republic, Aus-
tralia, India, Canada and the United States.
Sat Control’s strategic goal is to become globally innovative and competitive Solar Energy enterprise,
providing the most appropriate solar tracking technology for achieving the highest performance and most
cost-effective production of solar electricity.
Bogdan Bolka
CEO of Sat Control
Prefaces
Table of Contents
1. SOLAR LINEAR TRACKERS
1.a. DUAL AXIS SOLAR TRACKERS
1.a.1. SM44M3V15P ..................................................................... page 1-2 1.a.1.b. Iron-reinforcement cage JEKABBSM44M3V15P ............ page 3-4 1.a.2. SM54M1V6P ....................................................................... page 5-8 1.a.3. SM44M1V4P ....................................................................... page 9-11 1.a.4. SM44M1V3P ....................................................................... page 13-16 1.a.5. SM44M1V2P ....................................................................... page 17-20 1.b. SINGLE AXIS SOLAR TRACKERS
1.b.1. SM40M3V15P ..................................................................... page 21-22 1.b.1.b. Iron-reinforcement cage JEKABBSM44M3V15P ............ page 23-24 1.b.2. SM12SLT ........................................................................... page 25-28 1.b.3. SM40M1V4P ....................................................................... page 29-32 1.b.4. SM40M1V3P ....................................................................... page 33-36 1.b.5. SM40M1V2P ....................................................................... page 37-40 1.b.6. SM3SPMOG+ ..................................................................... page 41-44
2. SOLAR LINEAR MOTORS ACTUATORS
2.a. SM4S900M3 ......................................................................... page 45-47 2.b. SM4S520M1 ........................................................................ page 48-50
3. SOLAR POSITIONERS
3.a. SOLAR POSITIONER 2-AXIS MODULE NANO ............................. page 51-52 3.b. SOLAR POSITIONER 2-AXIS MODULE MICRO ............................. page 53-54
4. GROUND SCREWS
4.a. GROUND SCREW .................................................................. page 55-57 4.b. SET GROUND SCREWS .......................................................... page 58-60
5. MONITORING SYSTEM
5.a. HELIOS ANALYTICS ............................................................... page 61-62
5.b. ENIGMA ANALYTICS .............................................................. page 63-64
5.c. SIGMA SOLAR SERVER .......................................................... page 65-66
6. SAT CONTROL WEBSHOP
6.a. SAT CONTROL WEBSHOP ....................................................... page 67-68
1.a.1. SM44M3V15P
Product code: SM44M3V15P
Dual-Axis Solar Tracker SM44M3V15P
Dual-Axis Solar Tracker SM44M3V15P with accuracy better than 0,5 deg and backstructure for 15 pieces of
solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 25 m2 solar panel
surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses,
trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial
and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.
In a Year basis with Dual axis motor you can get 7% more income of energy compared to Single axis motor.
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
1
Mechanical Capabilities
Number of turning axis Dual-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚
Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm
Type of elevation shaft and stroke Linear motor SM4S900M3 with stroke of 900mm
Hour-angle shaft diameter and length Square tube 200x200 mm, L=2280 mm (steel)
Turning speed of hour angle shaft /
Turning speed of elevation shaft /
Max. dynamic torque of the hour-angle shaft /
Max. dynamic torque of elevation shaft /
Destructive torque of the hour-angle shaft /
Destructive torque of elevation shaft /
Backstructure size 5 x 5 m (H size 4 x 2,45 m)
Type of backstructure clamp Toothed scissors gripers - 60 pcs
Tube diameter for mounting Square tube 200x200 mm, H=3500 mm (steel)
Max. dimensions of a solar panel 15 pieces of 0.99 m x 1.95 m in total 25 m2
Max. weight of a solar panel 15 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval 1 minute (0.25°)
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ±±15% 4A(5A current capacity)
Backup battery CR 2512 coin
Turning time interval 1 minute (0.25°)
Max. Current of elevation shaft /
Standby consumption (when is not moving) 60mA @ 24 VDC
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1.5mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130km/h (in vertical position) up to 180km/h (in horizontal position)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 5000 (L) x 800 (W) x 800 (H) mm (Wooden Box is not icluded with kit)
Product weight 500kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage Yes, for additional payment
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
2
Technical Capabilities
1.a.1.b Iron-reinforcement cage JEKABBSM44M3V15P
Product code: JEKABBSM44M3V15P
Iron-reinforcement cage for Overground Concrete Foundation for Solar Tracker SM44M3V15P
The foundation of the solar power system can take various forms. Consequently, optimum consideration can
be given to the local conditions.
The rectangular overground foundation is generally used if a stony or rocky substrate precludes an under-
ground variant of the foundation structure.
1. IRON - REINFORCEMENT CAGE
3
1. IRON - REINFORCEMENT CAGE
4
Technical Capabilities
1.a.1.b Iron-reinforcement cage JEKABBSM44M3V15P
1.a.2. SM54M1V6P
Model code: SM54M1V6P
Dual Axis Solar Tracker SM54M1V6P
Dual-Axis Solar Tracker SM54M1V6P with accuracy better than 0,5 deg and backstructure for 6 pieces of solar panels dimensions 0,808 m x 1,580 m and weight of 25 kg max each. So together for 7,65 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at small and large solar power plants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 130km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software func-tion included.
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
5
Mechanical Capabilities
Number of turning axis Dual-Axis, Azimuth-Elevation System
Azimuth Angle Limit 270˚
Elevation angle 90˚
Type of Azimuth-angle engine Slew drive SM5M1
Type of elevation shaft and stroke Linear motor SM4S520M1
Azimuth-angle shaft diameter and length /
Turning speed of Azimuth angle shaft 0,9˚/s
Turning speed of elevation shaft 0,052 - 0,062 °/s at no load
Max. dynamic torque of the Azimuth-angle shaft Azimuth 150 Nm
Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA
Destructive torque of the Azimuth-angle shaft 1500 Nm
Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA
Backstructure size 2,424 m x 3,160 m
Type of backstructure clamp Toothed gripers - 24 pcs
Tube diameter for mounting Ø133 x 3 mm
Max. dimensions of a solar panel Array of 6 pieces of 0,808 m x 1,580 m in total 7,65 m2
Max. weight of a solar panel 6 pcs per 25 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Communication Data
Type of communication interface RS485
Networking solution for control from centre RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2A current capacity)
Backup battery /
Turning time interval 5 sec - 15 minute, but controlled via Sigma Solar Server Web based
Max. consumption during the operation of the Azimuth-angle shaft 500 mA @ 150 Nm
Max. Current of elevation shaft 500 mA @ 400Nm
Standby consumption (when is not moving) 25 mA ± 25% @ 24V
Power supply connection 1 cable of 2 wires with an Internal Cu Conductor of 1,0 mm2 for power and 1 twisted pair 0,25mm2 (2 wires) (not included with kit)
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Neutral Salt Spray (3000 h, EN ISO 9227 NSS) /
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product /
Product weight 155kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, but controlled via Sigma Solar Server Web based
Heliostat usage Yes, but controlled via Sigma Solar Server Web based
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
6
Technical Capabilities
1.a.2. SM54M1V6P
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
7
Real energy measurement of two equal solar panels (fixed and motorized)
Two equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 1.17 kWp (producer spec. at AM 1.5) Date: May 2011 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 4890.6Wh Average energy of motorized: 7920.9Wh
Note: Sum of motor energy consumption through all day is 35.5Wh or 0.22% of all collected energy.
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
8
1.a.2. SM54M1V6P
Legend:
1.a.3. SM44M1V4P
Model code: SM44M1V4P
Dual Axis Solar Tracker SM44M1V4P
Dual Axis Solar Tracker SM44M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel sur-face. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software function included.
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
9
Mechanical Capabilities
Number of turning axis Dual-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S520M1SP26A with stroke of 520 mm
Type of elevation shaft and stroke Linear motor SM4S520M1 with stroke of 520 mm
Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)
Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph
Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph
Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph
Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph
Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph
Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph
Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm
Type of backstructure clamp Toothed scissors gripers - 16 pcs
Tube diameter for mounting Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)
Max. dimensions of a solar panel 4 pieces of 0,99 m x 1,95 m in total 7,7 m2
Max. weight of a solar panel 4 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval Tipicaly 6 - 7 s
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2A current capacity)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph
Max. Current of elevation shaft 500 mA @ 400 Nm, see graph
Standby consumption (when is not moving) 20 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm
Product weight 55 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage Yes, for additional payment
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
10
Technical Capabilities
1.a.3. SM44M1V4P
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
11
Legend:
Legend:
Legend:
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Two equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 1.2 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh
Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.
1.a.3. SM44M1V4P
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
12
Legend:
Legend:
1.a.4. SM44M1V3P
Product code: SM44M1V3P
Dual-Axis Solar Tracker SM44M1V3P
Dual-Axis Solar Tracker SM44M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar
panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface.
A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig-
nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and
output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor.
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
13
Mechanical Capabilities
Number of turning axis Dual-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm
Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm
Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)
Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph
Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph
Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph
Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph
Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph
Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph
Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm
Type of backstructure clamp Toothed scissors gripers - 12 pcs
Tube diameter for mounting Ø60 - 68 mm (not included with kit)
Max. dimensions of a solar panel 3 pieces of 0,99 m x 1,95 m in total 5,8 m2
Max. weight of a solar panel 3 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval Tipicaly 6 - 7 s
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2A current capacity)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph
Max. Current of elevation shaft 500 mA @ 400 Nm, see graph
Standby consumption (when is not moving) 20 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm
Product weight 45 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Technical Capabilities
14
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
1.a.4. SM44M1V3P
Legend:
Legend:
Legend:
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
15
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh
Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.
1.a.4. SM44M1V3P
Legend:
Legend:
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
16
1.a.5. SM44M1V2P
Product code: SM44M1V2P
Dual-Axis Solar Tracker SM44M1V2P
Dual-Axis Solar Tracker SM44M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of solar
panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel surface.
A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig-
nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and
output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor.
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
17
Mechanical Capabilities
Number of turning axis Dual-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm
Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm
Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)
Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph
Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph
Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph
Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph
Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph
Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph
Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm
Type of backstructure clamp Toothed scissors gripers - 8 pcs
Tube diameter for mounting Ø60 - 68 mm (not included with kit)
Max. dimensions of a solar panel 2 pieces of 0,99 m x 1,95 m in total 3,9 m2
Max. weight of a solar panel 2 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval Tipicaly 6 - 7 s
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2A current capacity)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph
Max. Current of elevation shaft 500 mA @ 400 Nm, see graph
Standby consumption (when is not moving) 20 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm
Product weight 35 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage Yes, for additional payment
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
18
Technical Capabilities
1.a.5. SM44M1V2P
Legend:
Legend:
Legend:
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
19
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Two equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 0.6 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh
Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.
1.a.5. SM44M1V2P
Legend:
Legend:
1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS
20
1.b.1. SM40M3V15P
Product code: SM40M3V15P
Single-Axis Solar Tracker SM40M3V15P
Single Axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 15 pieces of solar panels
dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 25 m2 solar panel surface. A
Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig-
nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and
output is connected directly to inverter or an external charging device. Minimal wind resistance is 130km/h.
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
21
Mechanical Capabilities
Number of turning axis Single-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚ (Manually Adjusted)
Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm
Type of elevation shaft and stroke /
Hour-angle shaft diameter and length Square tube 200x200 mm, L=2280 mm (steel)
Turning speed of hour angle shaft /
Turning speed of elevation shaft /
Max. dynamic torque of the hour-angle shaft /
Max. dynamic torque of elevation shaft /
Destructive torque of the hour-angle shaft /
Destructive torque of elevation shaft /
Backstructure size 5 x 5 m (H size 4 x 2,45 m)
Type of backstructure clamp Toothed scissors gripers - 60 pcs
Tube diameter for mounting Square tube 200x200 mm, H=3500 mm (steel)
Max. dimensions of a solar panel 15 pieces of 0.99 m x 1.67 m in total 25 m2
Max. weight of a solar panel 15 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval 1 minute (0.25°)
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ±±15% 4A(5A current capacity)
Backup battery CR 2512 coin
Turning time interval 1 minute (0.25°)
Max. Current of elevation shaft /
Standby consumption (when is not moving) 60mA @ 24 VDC
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1.5mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130km/h (in vertical position) up to 180km/h (in horizontal position)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 5000 (L) x 800 (W) x 800 (H) mm (Wooden Box is not icluded with kit)
Product weight 500kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage Yes, for additional payment
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
22
Technical Capabilities
1.b.1.b Iron-reinforcement cage JEKABBSM44M3V15P
Product code: JEKABBSM44M3V15P
Iron-reinforcement cage for Overground Concrete Foundation for Solar Tracker SM40M3V15P
The foundation of the solar power system can take various forms. Consequently, optimum consideration can
be given to the local conditions.
The rectangular overground foundation is generally used if a stony or rocky substrate precludes an under-
ground variant of the foundation structure.
1. IRON - REINFORCEMENT CAGE
23
1. IRON - REINFORCEMENT CAGE
24
Technical Capabilities
1.b.1.b Iron-reinforcement cage JEKABBSM44M3V15P
1.b.2. SM12SLT
Product code: SM12SLT
Single-Axis Solar Tracker SM12SLT
Single-Axis Solar Tracker SM12SLT with accuracy better than 0,5 deg and backstructure for 12 pieces of
solar panels dimensions 0,82 m x 1,604 m and weight of 25 kg max each. So together for 20m2 solar
panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof
on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are
connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
25
Mechanical Capabilities
Number of turning axis Single-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm
Hour-angle shaft diameter and length Square tube 120x120 mm, L=5000 mm (steel)
Turning speed of hour angle shaft 2,33 mm/s
Max. dynamic torque of the hour-angle shaft >4780 Nm, see graph
Destructive torque of the hour-angle shaft >9000 Nm, see graph
Destructive torque of elevation shaft >1500 Nm, see graph
Backstructure size 4 Arms lenght of 3280 (L) mm
Type of backstructure clamp Toothed scissors gripers - 48 pcs
Max. dimensions of a solar panel 12 pieces of 0,99 m x 1,68 m in total 20,00 m2
Max. weight of a solar panel 12 pcs per 25 kg
Estimated service life 10.000 rotations of 200° (100°E + 100°W), or 20 years - (DC motor service in each 10 years or 5000 turns)
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval 1 minute (0,25°)
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (5A current capacity)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 4A @ 4780 Nm
Standby consumption (when is not moving) 60mA @ 24 VDC
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1.5mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <180 km/h (tested up to 230 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 5 (L) x 0,5 (W) x 0,5 (H) m (Wooden Box is not icluded with kit)
Product weight 350kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage No
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
26
Technical Capabilities
1.b.2. SM12SLT
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
27
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Two equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 2.16 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 9028.8Wh Average energy of motorized: 14623.2Wh
Note: Sum of motor energy consumption through all day is 35.5Wh or 0.24% of all collected energy.
1.b.2. SM12SLT
Legend:
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
28
1.b.3. SM40M1V4P
Product code: SM40M1V4P
Single-Axis Solar Tracker SM40M1V4P
Single-Axis Solar Tracker SM40M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of
solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel
surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses,
trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial
and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.
In a year basis with Dual Axis motor you can get 7% more income of energy compared to Single Ais motor.
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
29
Mechanical Capabilities
Number of turning axis Single-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm
Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)
Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph
Max. dynamic torque of the le shaft 200 - 330 Nm depend from HA, see graph
Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph
Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm
Type of backstructure clamp Toothed scissors gripers - 16 pcs
Tube diameter for mounting Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)
Max. dimensions of a solar panel 4 pieces of 0,99 m x 1,95 m in total 7,7 m2
Max. weight of a solar panel 4 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval Tipicaly 6 - 7 s
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2A current capacity)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph
Max. Current of elevation shaft 500 mA @ 400 Nm, see graph
Standby consumption (when is not moving) 20 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm
Product weight 52 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage No
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
30
Technical Capabilities
1.b.3. SM40M1V4P
Legend:
Legend:
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
31
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Two equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 1.2 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh
Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.
1.b.3. SM40M1V4P
Legend:
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
32
1.b.4. SM40M1V3P
Product code: SM40M1V3P
Single-Axis Solar Tracker SM40M1V3P
Single-Axis Solar Tracker SM40M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar
panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface.
A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic signalisations,
street light, cottages, small and large powerplants where solar panels are connected in serial and output is
connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
33
Mechanical Capabilities
Number of turning axis Single-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm
Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)
Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph
Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph
Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph
Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm
Type of backstructure clamp Toothed scissors gripers - 12 pcs
Tube diameter for mounting Ø60 - 68 mm (not included with kit)
Max. dimensions of a solar panel 3 pieces of 0,99 m x 1,95 m in total 5,8 m2
Max. weight of a solar panel 3 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval Tipicaly 6 - 7 s
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2,5A current capacity)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph
Max. Current of elevation shaft 500 mA @ 400 Nm, see graph
Standby consumption (when is not moving) 20 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm
Product weight 41 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage No
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
34
Technical Capabilities
1.b.4. SM40M1V3P
Legend:
Legend:
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
35
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh
Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.
1.b.4. SM40M1V3P
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
36
1.b.5. SM40M1V2P
Product code: SM40M1V2P
Single-Axis Solar Tracker SM40M1V2P
Single-Axis Solar Tracker SM40M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of
solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel
surface. A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic sig-
nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and
output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h.
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
37
Mechanical Capabilities
Number of turning axis Single-Axis
Hour Angle Limit 100˚, software and hardware limit
Elevation angle 15-90˚, adjustable start
Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm
Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)
Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph
Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph
Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph
Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm
Type of backstructure clamp Toothed scissors gripers - 8 pcs
Tube diameter for mounting Ø60 - 68 mm (not included with kit)
Max. dimensions of a solar panel 2 pieces of 0,99 m x 1,95 m in total 3,9 m2
Max. weight of a solar panel 2 pcs per 30 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ ***)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of positioner Din Rail positioner MICRO and externor cables
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval Tipicaly 6 - 7 s
Communication Data
Type of communication interface USB interface
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply 24 VDC ± 10% (2A current capacity)
Backup battery Backup for timer, position and data
Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph
Max. Current of elevation shaft 500 mA @ 400 Nm, see graph
Standby consumption (when is not moving) 20 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Box 190 (L) x 140 (W) x 70 (H) mm with connection harness
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm
Product weight 35 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage No
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
38
Technical Capabilities
1.b.5. SM40M1V2P
Legend:
Legend:
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
39
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 0.6 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh
Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.
1.b.5. SM40M1V2P
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
40
1.b.6. SM3SPMOG+
Product code: SM3SPMOG+
Solar Tracker SM3SPMOG+
Single-Axis Solar Tracker SM3SPMOG+ made to be supplied with power from 12 to 69 VDC from external
power supply. Without charger controller. Suitable for panels on grid Up to dimensions 2m x 1m usage at
homes on-grid at roof on houses, for trafic signalisation, for street light use, for power suplly at cottages, for
small and large powerplants where solar panels are connected in serial and output is connected directly to
inverter or an external charging device. Minimal wind resistance is 180km/h is required and price is imporant
too. All metal gear parts inside ensure high destruction forces.
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
41
Mechanical Capabilities
Number of turning axis Single-Axis
Hour Angle Limit 96˚ typical / 100˚ max., software and hardware limit
Elevation angle 75° manual fixation
Type of hour-angle engine Servo motor with position encoder on cogwheel
Hour-angle shaft diameter and length Ø40 mm, L=1150 mm (steel)
Turning speed of hour angle shaft 0,5°/s ± 25% @ 24V at no load
Max. dynamic torque of the hour-angle shaft 65 Nm
Destructive torque of the hour-angle shaft >200 Nm
Backstructure size 2 pcs of 1000 (H) mm
Type of backstructure clamp Toothed scissors gripers - 4 pcs
Tube diameter for mounting Ø50,0 - 60,0 mm
Max. dimensions of a solar panel 1 piece of 2,0 m x 1,0 m in total 2,0 m2
Max. weight of a solar panel 1 pc per 25 kg
Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years
Positioning System Data
Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)
Operating Protocol TdAPS (Time derived Astronomical Positioning System)
Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.
Type of Positioner Solar Positioner SP27C
Type of timer GMT clock with EOT and calendar
Type of application program for supervision and setting Solar tracking system monitor via web site
Setting and changing data via PC Yes, It can be setup up to 1000 parameters
Monitoring possibility via PC Yes, It can be setup up to 1000 parameters
Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC
Turning time interval 1 minute (0,25°)
Communication Data
Type of communication interface USB interface since beginning of the January 2010, before RS232
Networking solution for control from centre CAN BUS, RS485
Firmware - Software
Upgrading possibility via PC Yes, firmware via PC with help of web wizard
Electrical Data
Motor Power Supply Recommended 24 VDC (working from 12 to 69 VDC), (2,5 A current capacity @ 12V)
Backup battery CR 2512 coin
Max. consumption during the operation of the hour-angle shaft 500 mA @ 65 Nm
Standby consumption (when is not moving) 35 mA ± 25% @ 24V
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Environmental Data
Operating temperature -25°C to +70°C
Operation at humidity 0% to 100%, relative humidity
Max. safe wind speed <130 km/h (tested up to 180 km/h)
Corrosion, weather and chemical resistance
Packaging
Dimensions of a packed product 1 box of 1175 (L) x 135 (W) x 200 (H) mm
Product weight 9 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Anti-Shadowing Function Yes, included
Heliostat usage No
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
42
Technical Capabilities
1.b.6. SM3SPMOG+
● G.L. and +15˚ or -15˚ according to the season
● SET TO THE CALCULATED ANGLE● FOR EXAMPLE: 45˚
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
43
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured.
Test conditions: Solar panels (both): 200W (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear
Results: Average energy of fixed: 836,8Wh Average energy of motorized: 1354,0Wh
Note: Sum of motor energy consumption through all day is 20Wh or 1.45% of all collected energy.
1.b.6. SM3SPMOG+
Legend:
1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS
44
2.a. SM4S900M3
Product code: SM4S900M3
Professional Solar Linear Actuator - Motor SM4S900M3
Professional Solar Linear Actuator - Motor SM4S900M3. Suitable for PV panels, concentrators - CPV and Helio-stats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower pow-erplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device.
2. SOLAR LINEAR MOTORS
45
2.a. SM4S900M3
Mechanical Capabilities
Construction material of linear motor Stainless steel tubes and spindle and high carbon steel
Spindle type and material ACME stainless spindle
Stroke lenght 900 mm
Max. static load 15000 N
Dynamic load capacity 8000 N
Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º
Speed at no load 2,33 mm/s
Resolution 73,5 pulses/mm (min step is 0,0136 mm)
Backlash max 0,15 mm
Electrical Data
Motor Power Supply 24VDC +/- 15% 4A (5A current capability)
Backup battery /
Turning time interval /
Power consumption in operation Tipicaly 20-50 W, max 100 W
Standby consumption (when is not moving) /
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included with kit)
Environmental Data
Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)
Operation at humidity 0% to 100%, relative humidity
Corrosion, weather and chemical resistance
Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation
Packaging
Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm
Product weight 8,5 kg
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Heliostat usage Yes
CPV usage (concentrated PV usage) Yes, all types including round parabolic
Guarantee time 2 years as standard, 5 years for +20% - for additional payment, 10 years for +35% - for additional payment
2. SOLAR LINEAR MOTORS
46
Technical Capabilities
2.a. SM4S900M3
2. SOLAR LINEAR MOTORS
47
2.b. Motor SM4S520M1
Product code: Motor SM4S520M1
Professional Solar Linear Actuator - Motor SM4S520M1
Professional Solar Linear Actuator - Motor SM4S520M1. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment.
Suitable for PV panels, concentrators - CPV and Heliostats. Heliostats for addtional payment. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included.
2. SOLAR LINEAR MOTORS
48
49
2.b. SM4S520M1
Mechanical Capabies
Construction material of linear motor Stainless steel tubes and spindle and high carbon steel
Spindle type and material ACME stainless spindle
Stroke lenght 520 mm
Max. static load 3400 N
Dynamic load capacity 1000 N
Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º
Speed at no load 0,9 mm/s at no load, 0,4 mm/s at max. load
Resolution 457 pulses/mm (min step is 0,002188 mm)
Backlash max 0,2 mm
Electrical Data
Motor Power Supply 24VDC +/- 15% 4A (2A current capability)
Backup battery /
Turning time interval /
Power consumption in operation Tipicaly 3-6 W, max 10 W
Standby consumption (when is not moving) /
Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)
Environmental Data
Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)
Operation at humidity 0% to 100%, relative humidity
Corrosion, weather and chemical resistance
Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation
Packaging
Dimensions of a packed product 1box of 1000(L) x 80(W) x 60(H) mm
Product weight 3,46 kg + 1 kg box weight
Quality Certificates
International Protection Rating (IEC 60529) IP33
Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes
Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes
Optional Properties
Heliostat usage Yes, for additional payment
CPV usage (concentrated PV usage) Yes, all types including round parabolic - for additional payment
Guarantee time 2 years as standard, 5 years for +20% - for additional payment, 10 years for +35% - for additional payment
2. SOLAR LINEAR MOTORS
Technical Capabilities
2. SOLAR LINEAR MOTORS
50
2.b. SM4S520M1
3.a. SOLAR POSITIONER NANO
3. SOLAR POSITIONERS
51
Product code: POZSOL34A1DR
Solar Positioner NANO A for Dual Axis Tracking
With even better communication, usability and accuracy, the Solar Positioner NANO A set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, and RS485 plant communication: the new generation of positioners is ideally suited in mid-sized and large stand-alone grids. With the Sigma Server, Solar Positioner NANO A creates complete, integrated system for monitoring, diagnosis and configuration of the PV plant.
Professional• Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology
Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability
Reliable• Direct communication with the Sigma Solar Server via RS485 Service Interface• Meets the requirements of the EU Medium-Voltage Directive for grid safety management
3. SOLAR POSITIONERS
52
Technical Capabilities
Operation
Geometrical Operation Dual Axis Positioner
Type Slave Positioner
Communication
Tracker communication RS485 MODBUS
Interfaces
RS485 2 Pin Connector (Grounding Option)
Max. number of controlled devices
Solar Tracker 64
Max. communication range
RS485 1000 m
Power supply
Power supply External Power Supply
Input voltage 24VDC +/- 10%
Power consumption Type 4 W / max. 12 W / 0,5 W Stand By
Environmental conditions in operation
Ambient temperature -20 °C ... +60 °C
Relative air humidity 0 % ... 45 %, non-condensing
General data
Dimensions (W / H / D) in mm 110 / 55 / 17
Weight 100 g
Mounting location Indoors
Mounting options DIN rail mounting
Status display LEDs
Hall signals 2 Hall signals per Axis
End switches 2 Switches per Axis (one required, one optional)
Manual buttons 2 (East-West, Reference)
Upgrading In The Field by RS485 MODBUS
Languages
Software language English
Language versions – manual German, English, French, Italian, Spanish; Slovenian
Features
Warranty 5 years
Certificates and approvals www.Solar-Motors.com
Technical Capabilities
3.a. SOLAR POSITIONER NANO
3.b. SOLAR POSITIONER MICRO
3. SOLAR POSITIONERS
53
Product code: POZSOL36A1DR
Solar Positioner MICRO for Dual Axis Tracking
With even better communication, usability and accuracy, the Solar Positioner MICRO set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, USB tracker and RS485 plant communication: the new generation of positioners is ideally suited in single and middle size stand-alone grids. With the Sigma Server, Solar Positioner MICRO creates complete, integrated system for monitor-ing, diagnosis and configuration of the PV plant.
Professional• Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology
Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability
Reliable• Direct communication with Helios Analytics• Meets the requirements of the EU Medium-Voltage Directive for grid safety management
3. SOLAR POSITIONERS
54
Technical Capabilities
Operationnergy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
Operation
Geometrical Operation Dual Axis Positioner
Type Stand Alone Positioner
Communication
Tracker communication USB, RS485 MODBUS
Interfaces
RS485 2 Pin Connector (Grounding Option)
Max. number of controlled devices
Solar Tracker 1
Max. communication range
RS485 1000 m
Power supply
Power supply External Power Supply
Input voltage 24VDC +/- 10%
Power consumption 2Type 4 W / max. 12 W / 0,5 W Stand By
Environmental conditions in operation
Ambient temperature -20 °C ... +60 °C
Relative air humidity 0 % ... 45 %, non-condensing
General data
Dimensions (W / H / D) in mm 110 / 55 / 17
Weight 100 g
Mounting location Indoors
Mounting options DIN rail mounting
Status display LEDs
Hall signals 2 Hall signals per Axis
End switches 2 Switches per Axis (one required, one optional)
Manual buttons 2 (East-West, Reference)
Upgrading In The Field by RS485 MODBUS, or by USB
Languages
Software language English
Language versions – manual German, English, French, Italian, Spanish; Slovenian
Features
Warranty 5 years
Certificates and approvals www.Solar-Motors.com
Technical Capabilities
3.b. SOLAR POSITIONER MICRO
Product code: ZV76X60X1400
Ground Screws
Ground Screws made of high quality hot-galvanized steel, are widely used as strong supports for many ap-plications: flag poles and masts, timber construction, fencing systems, event structures, boards and banners, gardens and parks, Roads and traffics, sheds and containers etc. For us the important thing is they can be the easy and strong support for Solar Trackers and PV systems.
Key Features
• Foundation screws for any type of soil• Ideal for Photovoltaic Installations• Solid, forged and galvanized steel with welded screw threads• Stability is accomplished by means of compression during insertion to the ground. No other digging is required.• Production process is certified ISO9001:2008, ensuring the highest quality construction, reliability and flexibility.
Advantages
• No cement foundation or any other concrete construction needed• Optimum earthing accomplished by connecting the vertical parts with tin-plated copper wire, avoid ing any additional ground wiring, creating that way a solid, low resistance grounding Ground screws come with a 25-yeat anti-corrosion guarantee• No construction permit required• All systems are adjustable to customer requirements. • All systems are assembled using specialized personnel and machinery• Time saving and cost efficient• Can be subject to weight loads immediately• Environmentally friendly
4. GROUND SCREWS
4.a. Ground Screw
55
Model type Ground screw 76X1400 L=1400 d=76/60
Length of ground screw 1400 mm Outside diameter of ground screw 76,45mm x 2,6 mm (inner dia. 71mm with zinc)
Max. diameter of tube you can put in D63,5 mm L=2m
Screw thread size and pitch 620 mm
Surface treatment protection type and thick Hot bath zincking 200 um EN ISO1461
Technical Capabilities
4. GROUND SCREWS
4.a. Ground Screw
56
4. GROUND SCREWS
4.a. Ground Screw
57
4.b. SET Ground Screws
4. GROUND SCREWS
58
Product code: SETZV14C2X1SP
SET Ground Screws
SET Ground Screws provide a solid foundation whatever your project needs. Our SET Ground Screws is engi-neered for easy installation and provide years of dependable service. There is no need for gigging or laying a concrete foundation, drastically reducing cost and time associated with installation. SET Ground Screws also lessen the environmental impact of your solar project, allowing your panel arrays to blend in more naturally into terrain. Also importantly, SET Ground Screws are easily removable and reusable.
Set Components are:
• Ground Screw: 76x1400mm• Tube D60 2x1000 mm• Junction Clamp d=76/60
Key Features
Convenience
• Easy to install and use • No gigging or poring of concrete needed • Can be used in all types of soil • Fastest possible installation time • Ready to use immediately after installation
Environmentally friendly
• Compact design ensures the least impact on ground and surrounding area • Minimal site preparation needed • Since there is no need for concrete, the ground remains intact after screws are removed
Durability
• Made with galvanized steel and welded screw threads• Can be subject to weight loads immediately after installation • Provides solid foundation in all weather conditions• 25-year anti-corrosion guarantee
Value
• Reduced installation time and cost• Minimal materials required; provides the most cost effective foundation solution• Lowers system buy back times • Removable and reusable
Model type SET Ground Screws 76x1400 with tube D60 2x1000 with junction clamp
Length of ground screw 1400mm + 2 x tube D60,3 x 1000 + junction clamp Outside diameter of ground screw 76,45mm x 2,6mm + 2 x D60,3 x 3,25mm
Max. diameter of tube you can put in D63,5 x 3,25mm L=2000mm
Screw thread size and pitch 620mm
Surface treatment protection type and thick Hot bath zincking Zn 200 um EN ISO1461
Technical Capabilities
4.b. SET Ground Screws
4. GROUND SCREWS
Product code: SETZV14C2X1SP
59
4.b. SET Ground Screws
4. GROUND SCREWS
60
5. MONITORING SYSTEM - Helios Analytics
61
Professional management, monitoring and presentation of solar tracker
System management, monitoring, remote diagnosis, data adjusting and visualization: the Helios Analytics is the high-performance communication hub for single- to small-scale of solar trackers. It continuously display all the data from the solar trackers on the system side, thereby keeping you informed of the system‘s status at any given time. The Helios Analytics is a multi-functional, energy-efficient data system which offers importing and exporting settings data for solar trackers. Overview Safe• Remote monitoring, diagnosis and configuration of the solar trackers • Quick detection of malfunctions and notification in case of a failure • Powerful data system for importing and exporting all trackers setting data User-friendly• Central administration of all customer and tracker data• Easy remote access via PC
• Easy to understand reporting
5.a. Helios Analytics
Product code: PRGSIGHELANA1
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
5. MONITORING SYSTEM - Helios Analytics
62
5.a. Helios Analytics
Languages
Software language English
Language versions – manual German, English, French, Italian, Spanish, Slovenian
System requirements
Supported operating systemsWindows XP (installed version of Microsoft .NET Framework > 2.0 is required with 64 bit systems), Windows Vista (32-Bit and 64-Bit), Windows 7 (32-Bit and 64-Bit)
Hardware (minimum requirements)
Processor PIII 800 MHz (XP) / P4 1 GHz (Vista)
Main Memory 512MB (XP) / 1 GB (Vista)
Free hard disk space 265 MB (240 MB .Net / 25 MB application)
Resolution 1024 x 768 pixels
Color depth 256 colors
Communication
Tracker communication USB 2.0, CAN BUS 2.0 A
Type IP address, URL (e.g., DynDns)
Max. number of devices
USB 2.0 / CAN BUS 2.0 A 1 / up to 2000 trackers
RS485 / Ethernet /
Max. communication range
USB 2.0 / CAN BUS 2.0 A 5 m / 500 m (Twisted Pair Cable with cross section 0,7 mm2)
RS485 / Ethernet /
Software
Type Exe
Other Zip
Client Software Requirements No installation-dependent requirements for the operation
System information
Tracker overview Ideally suited for an overview over the solar tracker by presentation of the most important data
System settings Simple parameter setting for an entire device
Current system values
Summary of current device data. The display of minimum and maximum values, sums and averages (depicted for every device category) provides the operator with detailed information about the current status of their solar tracker
Device information
Device overview The most important device information at a single glance
Device settings Individual parameter adjustment for each device
Current device values Detailed information on the current values of the selected device
Information displayed
General information Time, date
System DataPower supply voltage, current motion, position, error codes, angle,tracker version, tracker type
Advanced System Data
Motor AA1, A2, A3, A4, A5 , A6, B1, B2, min range A, max range A, gear ratio A, I motor max A, coordinate mode A, geometry mode A, I motor factor A, night position A, go to reference A
Motor BA1, A2, A3, A4, A5 , A6, B1, B2, min range B, max range B, gear ratio B, I motor max B, coordinate mode B, geometry mode B, I motor factor B, night position B, go to reference B
Common settingsNight position time, link, U supply factor , group, conf. flags, SN1, SN2, SN3, can ID, options, run, delay n.p., run delay, panel wide, panel space, rtc correction, H target angle, V target angle
Individual set-up options
Values Three configurable pre-defined positions for snow, wind, etc.
The weather station for PV plants
Current system values /
Technical Capabilities
5. MONITORING SYSTEM - Enigma Analytics
63
Remote monitoring and maintenance of large PV plants
System monitoring, remote diagnosis, data storage and visualization: the Enigma Analytics is the high-per-formance communication hub for medium- to large-scale solar power plants. It continuously collects all the data from the solar trackers on the system side, thereby keeping you informed of the system‘s status at any given time. The Enigma Analytics is a multi-functional, energy-efficient data logger which offers a wealth of options for displaying, archiving and processing data, even in networks with strict security regulations. In case of the event “Error”, the Enigma Analytics informs you immediately by e-mail. Overview Safe• Remote monitoring, diagnosis and configuration of the PV plant from anywhere in the world • Quick detection of malfunctions and notification in case of a failure via e-mail• Powerful data logger for documentation of all important PV plant data
User-friendly • Easy remote access access via PC • Including free standard access for Enigma Portal for the entire service life of the PV plant
• Flexible display, evaluation, yield and event reports via Enigma Portal
5.b. Enigma Analytics
Product code: PRGENIANA1
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
5. MONITORING SYSTEM - Enigma Analytics
64
5.b. Enigma Analytics
Languages
Software language English
Language versions – manual German, English, French, Italian, Spanish, Slovenian
System requirements
Supported operating systemsWindows XP (installed version of Microsoft .NET Framework > 2.0 is required with 64 bit systems), Windows Vista (32-Bit and 64-Bit), Windows 7 (32-Bit and 64-Bit)
Hardware (minimum requirements)
Processor PIII 800 MHz (XP) / P4 1 GHz (Vista)
Main Memory 512MB (XP) / 1 GB (Vista)
Free hard disk space 265 MB (240 MB .Net / 25 MB application)
Resolution 1920 x 1080 pixels
Color depth 256 colors
Communication
Tracker communication RS485 / Ethernet TCP/11
Type IP address, URL (e.g., DynDns)
Max. number of devices
USB 2.0 / CAN BUS 2.0 A /
RS485 / Ethernet 50 / 50
Max. communication range
USB 2.0 / CAN BUS 2.0 A /
RS485 / Ethernet 1200 m / 100 m
Software
Type Exe
Other Zip
Client Software Requirements No installation-dependent requirements for the operation
System information
Tracker overview Ideally suited for an overview over the solar tracker by presentation of the most important data
System settings Simple parameter setting for an entire device
Current system values
Summary of current device data. The display of minimum and maximum values, sums and averages (depicted for every device category) provides the operator with detailed information about the current status of their solar tracker
Device information
Device overview The most important device information at a single glance
Device settings Individual parameter adjustment for each device
Current device values Detailed information on the current values of the selected device
Information displayed
General information Time, date, latitude, longitude, geometry
System DataPower supply voltage, current motion, position, error codes, angle, tracker version, tracker type, geometries
Advanced System Data
Motor AA1, A2, A3, A4, A5 , A6, B1, B2, min range A, max range A, gear ratio A, I motor max A, coordinate mode A, geometry mode A, I motor factor A, night position A, go to reference A, etc.
Motor BA1, A2, A3, A4, A5 , A6, B1, B2, min range B, max range B, gear ratio B, I motor max B, coordinate mode B, geometry mode B, I motor factor B, night position B, go to reference B, etc.
Common settingsNight position time, link, U supply factor , group, conf. flags, SN1, SN2, SN3, can ID, options, run, delay n.p., run delay, panel wide, panel space, rtc correction, H target angle, V target angle, etc.
Individual set-up options
Values /
The weather station for PV plants
Current system values Precise acquisition of irradiation intesity, temperature, ambient temperature and wind speed values
Technical Capabilities
5. MONITORING SYSTEM - Sigma Solar Server
65
The standardized data interface for large-scale systems
Large-scale plants and PV power utility stations require customized monitoring solutions and need to link sys-tems and components into one joint control system. Sigma Server set new communication standard in the field of automation technology, that enables simple and reliable data exchange between products and applications. With the Sigma Solar Server, Sat Control equipment can be very easily integrated into compatible systems. Overview Professional• Visualization, control and monitoring of large-scale plants • Integration of Sat Control equipment into existing control-room technology Flexible• Data interface in accordance with the communication standards in the field of automation technology• Simple and fast installation, high reliability
5.c. Sigma Solar Server
Product code: POZSOLSIG1
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
5. MONITORING SYSTEM - Sigma Solar Server
66
5.c. Sigma Solar Server
Communication
Communication with Enigma Analytics Ethernet
PC communication Ethernet
Tracker communication RS485
Interfaces
Analog and digital inputs 3 analog inputs / 3 open collector outputs
Ethernet 10/100 Mbit, RJ45
RS485 2 Pin Connector (grounding option)
Max. number of controlled devices
Solar Tracker 64
Max. communication range
Ethernet 100 m
RS485 1000 m
Power supply
Power supply External Power Supply
Input voltage 12VDC - 24VDC
Power consumption Type 4 W / max. 12 W
Environmental conditions in operation
Ambient temperature -20 °C ... +60 °C
Relative air humidity 0 % ... 45 %, non-condensing
Memory
Internal 0,5 MB
External SD card 2 GB
General data
Dimensions (W / H / D) in mm 110 / 55 / 17
Weight 100 g
Mounting location Indoors
Mounting options DIN rail mounting
Status display LEDs
Languages
Software language English
Language versions – manual German, English, French, Italian, Spanish; Slovenian
Features
Operation Integrated Web server (Internet browser)
Warranty 5 years
Certificates and approvals www.Solar-Motors.com
Technical Capabilities
6. SAT CONTROL WEBSHOP
67
6.a. Sat Control WebShop
Profit from our new online shop!
Conveniently order Sat Control quality from home and profit from:• A wide range of products and services• Surprisingly low prices• The high level of quality of quality of the products and components used and• The schedule effectiveness you have become accustomed to The Sat Control WebShop. 24/7 one-stop shopping for all-round solutions Tailor-madeto your needs fast and at the same level of high quality.
2 Real energy measurement of two equal solar panels (fixed and motorized)
Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col-lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to-gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio-stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-
6. SAT CONTROL WEBSHOP
68
6.a. Sat Control WebShop
Making a Payment
The following outlines the how you can make a payment through the WorldPay Payment Service and how we deal with the transaction.
How does the WorldPay Payment Service work?
1. A shopper visits an e-commerce website and selects the products/services that they would like to buy. 2. The shopper then proceeds to the merchant’s checkout with their shopping basket. This generates a sum-mary description of the purchase that is sent to WorldPay for payment processing. This submis sion is often referred to as the “purchase token”. 3. The shopper is redirected to WorldPay’s secure server where they are presented with a series of payment pages, enabling them to choose their payment method and enter their payment details.
4. WorldPay records the shopper’s payment details against the details submitted in the purchase token, to produce a transaction. 5. WorldPay forwards the transaction details to the card issuer for authentication. The issuer returns an authorised or declined response to WorldPay and a payment response page is then displayed to the shopper.
6. If the transaction was successful, WorldPay will also send the shopper a confirmation email, confirming the transaction details.
For more informations about paying through WorldPay, and for information on the status of your payments for pur-chases made at one of the shops that uses the WorldPay Payment Service, please visit: www.rbsworldpay.com
Published by and copyright © 2011:Sat Control d.o.o.Pozenik 10,SI-4207 CerkljeSlovenia
For more information, please contactour Customer Support Center.Phone: +386 4 281 62 15Fax: +386 4 281 62 13(Charges depending on provider)E-mail: support@sat-control.si
Order No. PC2011-V1.1 Printed in SloveniaDispo 34807, c4bs No. 7827fb 2674 440101 WS 11092.0
Printed on elementary chlorine-freebleached paper.
All rights reserved.Trademarks mentioned in this documentare the property of Sat Control d.o.o., its affiliates,or their respective owners.
Subject to change without prior notice.The information in this document containsgeneral descriptions of the technical optionsavailable, which may not apply in all cases.The required technical options should thereforebe specified in the contract.