PXD Grounding & Shielding

Fernando Arteche

MPI - February 2017

1. PXD GROUNDING • PXD ground have been defined in several documents that

have been prepared during the project. – Safety and equipment protection ground

– Detector Performance ground (Noise ground)

• Safety & Equipment protection ground (Installation) – Metal parts that can be energized – should be grounded

– Ground connections - Bonding and straps (size, etc)

– Electrical Laboratory codes and Low Voltage directive • IEC 61000-5-2 Ed 1.0 (1997): EMC-Installation and mitigation

guidelines: Earthing and cabling

• IEC 62305-1 to 4 Ed 1.0 (2006): Protection against lightning

• IEC 60364-5-54 Ed 3.0 (2011): Electrical installations of buildings. Selection and erection of electrical equipment- Earthing arrangements, protective conductors and protective bonding conductors.

• Detector performance ground ……

2 de 11 Grounding Meeting

February, 2017, MPI, Germany

• Cooling blocks is defined as PXD local ground – Cooling blocks (both sides) connected via low impedance

– PXD local ground connected to experiment ground

• PXD electronics ground (each leader) is connected to the cooling blocks (Multipoint ground topology)

• Cooling pipes isolated & grounded

1. PXD GROUNDING

3 de 11 Grounding Meeting

February, 2017, MPI, Germany

• Local ground implementation : Cooling blocks

– A unique ground structure for all PXD (Stainless steel) • It should guarantee the same potential from DC to hundreds of MHz of all

PXD electronics

* Plots: Tscharlie Ackermann

• Both sides connected together via CF tubes

– Beam pipe connection is not allowed

– Special coating needed to guarantee DC connection

– R < ????? mohm

1. PXD GROUNDING

4 de 11 Grounding Meeting

February, 2017, MPI, Germany

• Local & detector gorund implementation : electronics gnd connection

– AGND-DGND: Already have a common point at module level

– A connection to local ground and detector ground are needed ????

* P

lots

: Tsc

har

lie A

cker

man

n

To detector ground connection

Half block connection

1. PXD GROUNDING

5 de 11 Grounding Meeting

February, 2017, MPI, Germany

• Local ground implementation : Cooling pipes – CO2 and airflow pipes are electrically isolated

towards the outside via ceramic joint • Inner part is grounded to cooling blocks

– It avoids any noise penetrated to detector electronics

• External part should be grounded to detector – Safety requirement (Belle Il requirements) – No floating metallic pieces

Ceramic joint located around ???? mm from the CB

Local GND Exp GnD

* Plots: Tscharlie Ackermann

1. PXD GROUNDING

6 de 11 Grounding Meeting

February, 2017, MPI, Germany

2. CABLING • PXD have a complex topology for cabling the sub-detector.

– Voltages & Currents: Signal, Power & slow control cables

• Cables has been changed since last grounding discussion (2014)

• Attention has been paid to the cabling shielding because it may lead to some integration problems.

• Cable shield connection mainly defined by Belle II rules

– Both sides connection will be the preferred option

– Floating shields has to be minimized

– Other options need to be justified

7 de 11 Grounding Meeting

February, 2017, MPI, Germany

•Infiniband: Data Transmission Shielded & TSP Data, Ctrl, sense

•Kapton: Power, control & Data Power (up to 30V , 2A) Sensing (LV , mA) ?? Data, Ctrl, JTAG

•CAT6 : JTAG Shielded ??

2. CABLING

8 de 11 Grounding Meeting

February, 2017, MPI, Germany

•Service cable 1 (x2): Power Power Inner Shields External Shields

•LVDS cable (20pin): Power & control Ctrl Power ?? Sensing (LV , mA) JTAG Shielded ??

2. CABLING

9 de 11 Grounding Meeting

February, 2017, MPI, Germany

•Service cable 2: Power & control Power (up to 30V , 2A)

No inner shields

• JBX is considered the entrance to Vertex volume – It is the last good ground

• Shields connections: – External shields

• 15m long cables – Shield connected to both sides – It protects against electric and magnetic fields

– It decreases the ability of the cable to radiate

• 2m long cable – Shield connected 1 side (JBX side) – Electrostatic protection

– External and inner shields are independent

– Inner Shields • Floating or connected 1 side (JBX side)

– Drain wires not connected

2. CABLING

10 de 11 Grounding Meeting

February, 2017, MPI, Germany

3. SUMMARY

PW

CAT6

Infin

PW

LVDS

OPT

11 de 11 Grounding Meeting

February, 2017, MPI, Germany

BACKUP SLIDES

2. PXD GROUNDING • Several issues have been considered in the grounding

definition of PXD systems. Multipoint grounding topology.

Short ground connections

Belle II General Meeting June 18-21, 2014, KEK, Japan

2.2 Grounding topology: Grounding implementation - Straps

Common Belle II SVD-PXD Meeting

February 2012, Vienna, Austria 14 de 18

• Multiple equipment or units must be connected to a signal reference system (SRS) for direct connection bonding straps are required • Bounding straps: impedance highly influenced by inductance L, dependent on geometry resonances must be avoided

Local ground at detector level (HF conection)

Short connections

2. PXD GROUNDING

Belle II General Meeting June 18-21, 2014, KEK, Japan

2. PXD GROUNDING • Standards

Belle II General Meeting June 18-21, 2014, KEK, Japan

PXD Detector

Multipoint ground Topology

1.1 PXD GROUNDING: Topology

2.1 PXD GROUNDING: Topology

3.CABLING

Belle II General Meeting June 18-21, 2014, KEK, Japan

3.CABLING

Belle II General Meeting June 18-21, 2014, KEK, Japan