Quantitative In-Situ Measurement of Asperity Compression Under the Wafer During Polishing

Post on 07-Jan-2016

33 views 2 download

description

Quantitative In-Situ Measurement of Asperity Compression Under the Wafer During Polishing. Caprice Gray MRS Spring Meeting San Francisco, CA March 30, 2005. Overview. Introduction Experimental Setup Polisher Dual Emission Laser Induced Fluorescence Pad Compression Experiments and Results - PowerPoint PPT Presentation

transcript

Quantitative In-Situ Measurement of Asperity Compression Under

the Wafer During PolishingCaprice Gray

MRS Spring MeetingSan Francisco, CA

March 30, 2005

Overview

• Introduction• Experimental Setup

– Polisher– Dual Emission Laser Induced Fluorescence

• Pad Compression Experiments and Results– Static Compression– Dynamic Compression

• Conclusion

Introduction

• DELIF is used to collect grayscale images that represent properties under the wafer during polishing– pH, temperature, fluid layer thickness

• Previous thickness measurement– time averaged– low spatial resolution

• New DELIF Setup– Laser enables instantaneous imaging– Larger distance between lens and CCD – 4 m/pixel

• In these experiments we use fluid thickness measurements to infer what is happening to pad asperities during polishing

Polishing Setup

Motor

Platen

RotoPol-31

Wafer

Force Table

Steel Table

DELIF

0

0.2

0.4

0.6

0.8

1

300 400 500 600

Wavelength (nm)

Inte

nsi

ty (

au)

Camera B Filter

Camera A Filter

Pad Em.392 nm

Calcein Abs492 nm

Calcein Em.530 nm

Pad Abs. 346nm

Laser Em.355 nm

Slurry Abs.

Slurry Em.

Why Examine 2 Emissions?

Pad

Slurry

=

Ratio

Division of 2 images cancels variationsin image source intensity

Experiments

• Pads: flat Fruedenberg FX9– Global vs. Local topography

• Static: flat glass wafer• Dynamic: etched glass wafer

Static Pad Compression• 2 Images were taken in a single

section of the pad.– 0 kPa– 70 kPa

• 17 total sections were imaged and analyzed.

Histogram Analysis

• The asperity size distribution is the same shape as the fluid layer thickness distribution.

• When force is applied to the wafer, the distribution changes both shape and location.

• Standard deviation comparison → pad compression

• Peak location → fluid layer thickness.

• Compression factor: 0

0

Static Compression Results

= 133.9 - 22.2R2 = 0.7

0

10

20

30

40

50

60

0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5

Compression Factor

(S

lurr

y T

hic

knes

s) (

um

)

Dynamic Pad Compression

• Two wafers were etched and contain square wells– 14.5 m deep– 27 m deep

• Asperities can expand under these wells.

• Histograms from regions 1 and 2 are compared

• Run Conditions:– Pad/wafer rotation: 30 RPM– Continuous conditioning– Slurry flow: 50 cc/min– Force applied to wafer: 10 kPa

Dynamic Results

(7m)

Conclusions

• DELIF can be used to measure slurry film thickness with asperity scale resolution.

• Over the 6 mm2 regions imaged, Different amounts of fluid can be displaced due to the same applied global forces.

• Pad topography deformation can be inferred from fluid layer thickness measurements.– During a static application of force, local pad compression is

roughly linearly related to the amount of fluid displaced by the compression

– In the dynamic case, asperity expansion into 27 m deep wells was greater than expansion into 14.5 m deep wells.