Post on 29-Jan-2016
transcript
RTD Basic Training
Agenda• Control PC Network Connection Setup• Configure RTD
– RTD License Installation – RTD Environment Configuration– Archives
• Basic RTD use– Opening a test– Running a test– Execution View– Results View
• Protocol Analyzer• Campaign Manager• Command Line Interface• Documentation• Support
UE
Control PC
Ethernet Switch
ME7834L & Control PC Setup
License Installation• When starting RTD for the first time, or after
clearing the license:
• To clear the license:Start Menu > All Programs > Rapid Test Designer > License Utilities >
Clear License
Environment Manager• RTD Tools menu
• -> Options
•“C2K Procedures” & “MD8470 Parameters” for MD8470A setup
•“UTRAN-GERAN L3 Procedures” & “MD8480 Parameters” for MD8480 setup
•“LTE Layer 3 Procedures” & “MD8430 Parameters” for MD8430 setup
C2K Procedures• For ME7843L system with two MD8470s, add second element under Group
UTRAN-GERAN L3 Procedures• ipAddress set for MD8480C based on serial number
• Serial number 6200??wxyz -> ipAddress 1.1.1wx.1yz
• ueIPAddressIPv4 set for ME7834L data plane
LTE Layer 3 Procedures• ipAddressIPv4 set for ME7834L data plane
MD8430 Parameters• ipAddress set for MD8430A based on serial number
• Serial number 6200abcdef -> ipAddress 1.1ab.1cd.1ef
MD8470 Parameters• Add elements to match the number of MD8470s in the configuration
MD8480 Parameters• ipAddress set for MD8480C based on serial number
• Serial number 6200??wxyz -> ipAddress 1.1.1wx.1yz
Common Parameters• Set cable loss correction files
• Use full paths for correction files • Set instrumentMap tomatch ME7834L configuration
Archives• To add an archive:
1. Click Add Archive
2. Browse to Archive Location
3. Name Archive
Opening a Test
• Click Open…
• Use drop-down menu to select archive
• Select test
and click Open
Running Tests
• Once test has opened, simply click the Run button
• RTD moves to Execution view, and test starts to run
Execution View
Timers in use
User Events
Runtime MessagesDiagram View
Stop Button
Run Comments
User Input Command
Runtime Data
Message SequenceChart
Results View
Results Navigator
Verdict Criteria
Message Detail
Message Sequence Chart
Historic Design
Protocol Analyzer
Protocol Analyzer
• Message Sequence Chart and TTCN views
• Selectable layers
• Green = Configuration• Red = Protocol
• Time stamps for reference
• RTD procedure block separators
Campaigns
• Drag and drop testcases into campaign
• Overwrite default timeout for specific tests
• Individual repeat condition for each test• Run once• Run until fail or max runs• Run until pass or max runs
Campaign Results
• Results are displayed for individual campaign runs, and an overview can be displayed to compare with past runs
Command Line Interface
• Create batch files for automated testing of sequences of testcases
• Can be run remotely using a client PC connected to the control PC
Documentation
• Stored in C:\Program Files\Anritsu\Rapid Test Designer\4.10.0\Docs– MX786201A_4.10.0_Customer_Release_Note.pdf– RTD (Rapid Test Designer) User Guide -
MX786201A.pdf– RTD_Quick_Start_Guide.pdf– RTD_Tutorial_Help.pdf– Reference Manual and Parameters doc for each
procedure library
Support1. Register at https://secure.eu.anritsu.com/wireless-support/index.php
2. Raise tickets online or send email to:
RTD.Support@anritsu.com