RTD Basic Training. Agenda Control PC Network Connection Setup Configure RTD –RTD License...

Post on 29-Jan-2016

314 views 5 download

Tags:

transcript

RTD Basic Training

Agenda• Control PC Network Connection Setup• Configure RTD

– RTD License Installation – RTD Environment Configuration– Archives

• Basic RTD use– Opening a test– Running a test– Execution View– Results View

• Protocol Analyzer• Campaign Manager• Command Line Interface• Documentation• Support

UE

Control PC

Ethernet Switch

ME7834L & Control PC Setup

License Installation• When starting RTD for the first time, or after

clearing the license:

• To clear the license:Start Menu > All Programs > Rapid Test Designer > License Utilities >

Clear License

Environment Manager• RTD Tools menu

• -> Options

•“C2K Procedures” & “MD8470 Parameters” for MD8470A setup

•“UTRAN-GERAN L3 Procedures” & “MD8480 Parameters” for MD8480 setup

•“LTE Layer 3 Procedures” & “MD8430 Parameters” for MD8430 setup

C2K Procedures• For ME7843L system with two MD8470s, add second element under Group

UTRAN-GERAN L3 Procedures• ipAddress set for MD8480C based on serial number

• Serial number 6200??wxyz -> ipAddress 1.1.1wx.1yz

• ueIPAddressIPv4 set for ME7834L data plane

LTE Layer 3 Procedures• ipAddressIPv4 set for ME7834L data plane

MD8430 Parameters• ipAddress set for MD8430A based on serial number

• Serial number 6200abcdef -> ipAddress 1.1ab.1cd.1ef

MD8470 Parameters• Add elements to match the number of MD8470s in the configuration

MD8480 Parameters• ipAddress set for MD8480C based on serial number

• Serial number 6200??wxyz -> ipAddress 1.1.1wx.1yz

Common Parameters• Set cable loss correction files

• Use full paths for correction files • Set instrumentMap tomatch ME7834L configuration

Archives• To add an archive:

1. Click Add Archive

2. Browse to Archive Location

3. Name Archive

Opening a Test

• Click Open…

• Use drop-down menu to select archive

• Select test

and click Open

Running Tests

• Once test has opened, simply click the Run button

• RTD moves to Execution view, and test starts to run

Execution View

Timers in use

User Events

Runtime MessagesDiagram View

Stop Button

Run Comments

User Input Command

Runtime Data

Message SequenceChart

Results View

Results Navigator

Verdict Criteria

Message Detail

Message Sequence Chart

Historic Design

Protocol Analyzer

Protocol Analyzer

• Message Sequence Chart and TTCN views

• Selectable layers

• Green = Configuration• Red = Protocol

• Time stamps for reference

• RTD procedure block separators

Campaigns

• Drag and drop testcases into campaign

• Overwrite default timeout for specific tests

• Individual repeat condition for each test• Run once• Run until fail or max runs• Run until pass or max runs

Campaign Results

• Results are displayed for individual campaign runs, and an overview can be displayed to compare with past runs

Command Line Interface

• Create batch files for automated testing of sequences of testcases

• Can be run remotely using a client PC connected to the control PC

Documentation

• Stored in C:\Program Files\Anritsu\Rapid Test Designer\4.10.0\Docs– MX786201A_4.10.0_Customer_Release_Note.pdf– RTD (Rapid Test Designer) User Guide -

MX786201A.pdf– RTD_Quick_Start_Guide.pdf– RTD_Tutorial_Help.pdf– Reference Manual and Parameters doc for each

procedure library

Support1. Register at https://secure.eu.anritsu.com/wireless-support/index.php

2. Raise tickets online or send email to:

RTD.Support@anritsu.com