Salter labs

Percent-O2-Lock®

Venturi SystemSingle unit variable venturi system deliveringaccurate concentrations of oxygen (from 24 to 50%) with a single unit.

Features■■ Transparent, air-entrainment mask with soft

anatomical form

■■ Easily adjusted, variable venturi system

■■ Unique, springloaded mechanism locksprescribed concentration in place

■■ Wide, adjustable elastic strap or over-the-earstyle available in adult configuration

■■ Durable, plastic humidity cup, standard

Benefits■■ Ideal for long-term users and edentulous

patients. Better fit.

■■ Accurate concentrations of oxygen with single unit

■■ Ensures safety and correct oxygen concentrations

■■ Fits comfortably in either configuration tohold mask in place

■■ Allows utilization of a humidifier or nebulizer withmask when prescribed

®

slc-53

SLC-53 6/4/08 3:57 PM Page 1

Percent-O2-Lock® Venturi System P/N 8150

The Percent-O2-Lock® air entrainment oxygen mask includes a rotating sleeve, opening and closing an airentrainment window. This provides the ability to deliver seven (7) fixed oxygen concentrations to aspontaneously breathing patient. Concentration levels are easily dialed and locked in. The dial-in airentrainment assembly is affixed to a standard aerosol mask. A high humidity adaptor permits use of anebulizer with mask if prescribed.

26%24%

28%31%35%40%50%

26%24%

28%31%35%40%50%

All units arepre-assembledwith the dialpre-set at 24%

To change a setting,pull the sleeve backuntil the spring iscompletelycompressed. Thenturn the sleeve to theprescribed setting.

Releasing the sleeveand spring forcesthe sleeve into itssetting. The springalso locks the sleeveinto place

The high humidity adaptor fits over and ispushed on until it locks on the post extendingaway from the tip of the cone. Caution: THE HUMIDIFYING ORNEBULIZING DEVICE MUST BE DRIVEN BY COMPRESSED AIR.

Ordering InformationUnits Elastic-Strap Over-The-Ear (per case) Style Style

Percent-O2-Lock® Venturi System*Adult Percent-O2 Lock® air entrainment 50 8150 8050system with humidity cup, 7'oxygensupply tube, and mask

Adult Percent-O2-Lock®/trach tee air 50 8054entrainment system with humidity cup and 7'oxygen supply tube

Adult Percent-O2-Lock® air entrainment 50 8056assembly with humidity cup(without mask or oxygen supply tube)

Adult Percent-O2-Lock® air entrainment 50 8057assembly (without mask, oxygen supply tube or humidity cup)

Adult Percent-O2-Lock® air entrainment 50 8058assembly with 7' oxygen supply tubeand humidity cup (without mask)

Adult Percent-O2-Lock® air entrainment 50 8059assembly with 7' oxygen supply tube(without mask or humidity cup)

Pediatric Percent-O2-Lock® air 50 8121entrainment system with humiditycup, 7'oxygen supply tube, and pediatric mask

Printed in U.S.A. © Copyright, 1991, Salter Labs® Revised July, 2008 SLC-53

100 W. Sycamore Road - Arvin, CA 93203Phone: 661-854-31661-800-421-00241-800-235-4203Fax: 661-854-3850Toll Free Fax: 1-800-628-4690Fax: 661-854-3850E-mail: salterlabs@us.salterlabs.comwww.salterlabs.com

0482ISO 9001 & ISO 13485

®