SIEMEN HJD63B400

Post on 16-Oct-2014

69 views 0 download

transcript

Molded Case Circuit BreakersJD 400A Frame Sentron SeriesType HJD6-A, HJXD6-A®® Black LabelInterchangeable Trip

ContinuousCurrent Rating@40°C

Complete BreakerUnassembled with Lugs

CatalogNumber

ListPrice $

Frame Only

CatalogNumber

ListPrice S

Trip Unit Only

CatalogNumber

ListPrice $

2-Pole 600V AC, 250V DC (3 Pole Width)200225250300350400

HJD62B200HJD62B225HJD62B250HJD62B300HJD62B350HJD62B400

4250.004250.004250.004250.004250.004250.00

HJD62F400 2696.00

JD62T200JD62T225JD62T250JD62T300JD62T350JD62T400

1456.001456.001456.001456.001456.001456.00

3-Pole 600V AC, 500V DC®®©200225250300350400

HJD63B200HJD63B225HJD63B250HJD63B300HJD63B350HJD63B400

5122.005122.005122.005122.005122.005122.00

HJD63F400 3353.00

JD63T200JD63T225JD63T250JD63T300JD63T350JD63T400

1622.001622.001622.001622.001622.001622.00

Type —JD6, HHJXD6-A2-Pole 600V AC (3 Pole Width) Black Label

200225250300350400

HHJD62B200HHJD62B225HHJD62B250HHJD62B300HHJD62B350HHJD62B400

5110.005110.005110.005110.005110.005110.00

HHJD62F400 3556.00

JD62T200JD62T225JD62T250JD62T300JD62T350JD62T400

1456.001456.001456.001456.001456.001456.00

3-Pole 600V AC®200225250300350400

HHJD63B200HHJD63B225HHJD63B250HHJD63B300HHJD63B350HHJD63B400

6143.006143.006143.006143.006143.006143.00

HHJD63F400 4374.00

JD63T200JD63T225JD63T250JD63T300JD63T350JD63T400

1622.001622.001622.001622.001622.001622.00

Type CJD6Fuseless Current Limiting Red LabelNon-Interchangeable Trip (Assembled Circuit Breakers Without Lugs)

ContinuousCurrent Rating@40°C

200225250300350400

2-Pole

600V AC/250V DC

For 2-pole applicationuse outside poles of3-pole circuit breaker

3-Pole

600V AC/500V DC

CatalogNumber

CJD63B200CJD63B225CJD63B250CJD63B300CJD63B350CJD63B400

ListPrice $

6400.006400.006400.006400.006400.006400.00

SELECTION/DIMENSIONS

D1

Figure 1

-W-

Figure 2

Dimensions (in inches)

BreakerType

Figure 1JXD2-A, JXD6-A, JD6-AHJD6-A, HJXD6-A, HHJD6,HJD6, HJXD6, HHJXD6,JXD6-ETI®

Figure 2CJD6, CJD6-ETI8

W

7.5

7.5

L

1 1

17.86

D

4

4

ToHandleD1

5.44

5.44

CD O

II

Enclosures

Type

13R1 24X7, 9 (200-250A)7, 9 (300-400A)

Neutral

CatalogNumber

J6N1J6N3RJ6N12LD6SS4EC4EE

W60992

ListPrice $

203.001092.00568.00

5443.003773.005221.00

308.00

Shipping WeightsNumber ofPoles

Number perCarton

ShippingWeight (Ibs.)

JXD2, JXD6, JD6, HJD6, HHJD6Assembled Breaker (less terminals)23

11

17.519.5

JD6, HJD6, HHJD6 Frame Only23

11

1 415.5

JD6 Trip Unit Only23

11

3.54

CJD6 Complete Assembled Breaker(less terminals)23

11

29.531.5

For inches / millimeters conversion,see Application Data section.

2-pole units available in 3-pole construction.©When wired as shown on page 49, this circuit breaker is

UL listed and rated for use on 500V DC ungrounded UPSsystems only.

©For non interchangeable 3-pole HJD6 or HHJD6 typecircuit breaker change the prefix identifier to HJXD6or HHJXD6. Price equals price of frame plus price oftrip, e.g. price of HJXD63B400 equals price ofHJD63F400 plus price of JD63T400. Order lugsseparately.

©JXD6-ETI, CJD6-ETI see page 106 for ordering information.©Type HJXD6, HHJXD6 Circuit Breakers are UL listed for

reverse fed applications.©CE applies to non interchangeable type HJXD only

Built to order Allow 2 weeks for production.

Discount Schedule F Siemens Electrical Products SPEEDFAX 2000

Molded Ca*^ r:—r:* Rrpp^^r^JD 400A FraiTia oun^u,, od,io5

SELECTION

Type JXD2-A240V AC, 250V DC Blue LabelNon-Interchangeable Trip (Assembled Circuit Breaker without Lugs)

ContinuousCurrent Rating@40°C200225250 ;-"-'300350400

2-Pole (3 Pole Width)CatalogNumberJXD22B200JXD22B225JXD22B250JXD22B300JXD22B350JXD22B400

ListPrice $1996.001996.001996.001996.001996.001996.00

3-PoleCatalogNumberJXD23B200JXD23B225JXD23B250JXD23B300JXD23B350JXD23B400

ListPrice S2425.002425.002425.002425.002425.002425.00

^ 600V AC, 500V DC®

\</>

t aIIO CO

Iffue LabelNon-Interchangeable Trip (Assembled Circuit Breaker without Lugs)

200225250300350400

Type JD6-A

JXD62B200JXD62B225JXD62B250JXD62B300JXD62B350JXD62B400

2494.002494.002494.002494.002494.002494.00

JX063B200JXD63B225JXD63B250JXD63B300JXD63B350JXD63B400

2950.002950.002950.002950.002950.002950.00

Blue LabelInterchangeable Trip

ContinuousCurrent Rating@40°C

Complete BreakerUnassembled with LugsCatalogNumber

ListPrice S

Frame OnlyCatalogNumber

ListPrice S

Trip Unit OnlyCatalogNumber

ListPrice S

2-Pole 600V AC, 250V DC (3 Pole Width)200225250300350400

J062B200JD62B225JD62B250JD62B300JD62B350JD62B400

2592.002592.002592.002592.002592.002592.00

JD62F400 1038.00

JD62T200JD62T225JD62T250JD62T300JD62T350JD62T400

1456.001456.001456.001456.001456.001456.00

3-Pole 600V AC, 500V DC®

Interrupting Ratings

Instantaneous Adjustment Trip Range

200225250300350400

JD63B200JD63B225JD63B250J063B300JD63B350JD63B400

3097.003097.003097.003097.003097.003097.00

JD63F400 1328.00

JD63T200JD63T225JD63T250JD63T300JD63T350JD63T400

1622.001622.001622.001622.001622.001622.00

BreakerTypeJXD2-2JXD6-2, JD6-AHJD6-A, HJXD6-AHHJD6-A, HHJXD6®CJD6

RMS Symmetrical Amperes (KA)UL 489 AIR (File E10848)Volts AC(50/60Hz)240

6565

100200200

480—

3565

100150

600—

253550

100

Volts DC

25030 (2-P)30 (2-P)30 (2-P)—

30 (2-P)

500®—

25 (3-P)35 (3-P)—

50 (3-P)

IEC 947-2Volts AC (50/60HZ)220/240leu—

65100200

Ics—

3350

100—

380/415leu—

4065

100—

Ics—203350—

500leu—304265—

Ics—1 52133—

Breaker AmpereRating

200-300350-400

Nominal Instantaneous ValuesLow

12502000

2

14302290

3

16102570

4

17902860

5

19603140

6

21403430

7

23203710

High

25004000

Ordering InformationComplete Breaker Unassembledwith LugsPrices of JD6, HJD6, and HHJD6breakers include frame, trip andboth line and load lugs (TA2J6500).When ordered by these catalognumbers, the customer will receivethe frame, trip, and lugs separatelypackaged. For applicationsrequiring different lugs, orderindividual items as needed.Complete Breaker Assembledwithout LugsPrices of JXD6, HJXD6, HHJXD6,and CJD6 include frame with non-interchangeable trip unit installedonly. Order required lugs separately.For line and load lugs (TA2J6500)installed, add suffix "L" to catalognumber (add 2 times list price oflugs for each pole).100% RatedTypes JXD2, JXD6 and HJXD6breakers are available with 100%ratings. To order add suffix "H" tocatalog number, and 10% to listprice. 100% rated JD breakersrequire the use of 90°C Cu cableand lugs TC1J6600 or TC2J6500.50°C Applications see page 1 1 1 .400Hz Applications see page 1 1 1 .

Lugs For 75°C Wire®

CatalogNumberTA2J6500

TA1L6750

TC1J6600TC2J6500

CablesperLug1 , 2211111 , 2

WireRange#3/0-500 kcmil Cu#4/0-500 kcmil Al250-500 kcmil Al500-750 kcmil Al500-600 kcmil Cu#3/0-600 kcmil Cu#3/0-500 kcmil Cu

ListPriceEachS24.50

60.00

61.0060.00

Compression LugCCL600 1 #1/0-500 kcmil Cu/AI 118.00

®Type JXD6 circuit breakers are UL Listed for reversefeed applications.

©When wired as shown on page 49, this circuit breaker isUL listed and rated for use on 500V DC ungrounded UPSsystems only.

©See Note: A, page 108.®HHJD6 type circuit breakers meet the UL criteria for

"current limiting" at 240 and 480V AC.Note: JD frame qualified to UL489 supplement B

"NAVAL." See page 111 for additional information.

Modifications page 111Enclosures pages 34-46Accessories pages 108-126

Built to order. Allow 2 weeks for production.

mLM Siemens Electrical Products SPEEDFAX 2000 Discount Schedule F

Molded Case Circuit Breakers.

Reference GuideSELECTION /APPLICATION

iiitiimcii ividyueuu nip DiedKeis

Page

Ratings

AC

DC

Dimensions ininches

OvercurrentDevices

Accessories &Modifications

IndividualEnclosures

PolesAmperes, ContinuousVolts 50/60HZ

Interrupt RatingSymmetrical RMSAmperes

2-Pole3-Pole240V

UL 480V600V

220/240V —— ——Ics

IEC947-2 380/415V 'CU

50/60HZ Ics

500V 'CU

Ics2-Pole 250V DC Interrupting Ratings3-Pole, 500V DC Interrupting Ratings®Height

Width2-Pole3-Pole

DepthThermal and Adjustable Magnetic TripAdjustable Magnetic Trip Only

Motor Circuit ProtectorMolded Case SwitchUndervoltageTripShunt TripAuxiliary SwitchAlarm SwitchMechanical InterlockRear Connection StudsElectric Motor OperatorPlug-In Mounting AssemblyFungus Proofing (ref. page 106)Type 1 — Indoor SurfaceType 1 — Indoor, FlushType 3R — Outdoor-RainproofType 7 — Flammable Gas AtmosphereType 9 — Combustion DusttightType 5, 12 — Lint, Fine Dust, Oils, CoolantsType 12K — Semi-Dusttight

General Purpose Breakers

JXD2-A782,3200-400

240

65,000————————30,000—11.00

7.50

4.00

y

yyyyyyyyjyy—yyyy

JD6-A,JXD6-A782,3200-400

600

65,00035,00025,00065,00033,00040,00020,00030,00015,00030,00025,00011.00

7.50

4.00

y—yyy•jjy

yyyy

y—yyyyy

HJD6-A,HJXD6-A792,3200-400

600

100,00065,00035,000

100,00050,00065,00033,00042,00021,00030,00035,000

11.00

7.50

4.00y-—yy

yyyV

yyyy~yyyy/

HHJD6-A,HHJXD6-A792,3200-400

600

200,000100,00050,000

200,000100,000100,00050,00065,00033,000

——11.00

7.50

4.00

y-—yyyyyyyyyy—yyvy/

CJD6792,3200-400

600

200,000150,000100,000——————30,00050,00017.86

7.50

4.00yyyyvyyyyyyyy————y—

LD6,LXD6802,3450-600

600

65,00035,00025,00065,00033,00040,00020,00030,00015,00030,00025,00011.00

7.50

4.00

V

</

yvy

yyyyyyyyyyyyV

y

HLD6,HLXD6812,3250-600

600

100,00065,00035,000

100,00050,00065,00033,00042,00021,00030,00035,000

11.00

7.50

4.00y

—^yyyyyyyyy—y/\/yyy

HHLD6,HHLXD6812,3250-600

600

200,000100,00050,000

200,000100,000100,00050,00065,00033,000

——11.00

7.50

4.00y

-—yyyyyyyyyy—yy<

yyy

CLD6812,3450-600

600

200,000150,000100,000——————

30,00050,000

17.86

7.50

4.00y

V7

yy

V

yyyyyyyy————y—

DO O

II3-en

For inches / millimeters conversion, see Application Data section.®For DC UPS application

Siemens Electrical Products SPEEDFAX 2000

Molded Case Circuit BreakersINTRODUCTION

What's New?With this Speedfax, Siemens Energy &Automation is proud to announce severalnew products. These new conceptsserve the OEM and power distributionmarkets.

CE MarkingA wide range of Sentron®thermalmagnetic circuit breakers has been fullytested for compliance with the Europeancommunity's Low Voltage Directive, andcarry the CE mark, indicating theircompliance with that directive. These arenoted in the Speedfax with the stylizedCE in watermark behind the catalognumbers. Declarations of conformity areavailable for these products. A point ofmisunderstanding lies in the area ofhandle operators. A handle operatoralone, such as that for the Max-flex,since there is no applicable EuropeanDirective, may not carry the CE mark. Themark is affixed to the finished equipmentthat incorporates the handle, but not tothis component device.

Sensitrip Ammeter Display Unit

The Ammeter display for the Sensitrip®electronic trip family of breakers brings anew level of diagnostic capability even tonon-interconnected breakers. Having aninternal clock calendar, it can record thedate and time of each trip event thatoccurs. Other products rely on beingconnected in a full network to time stampevents. This exclusive patented Siemensdevice provides current metering andbreaker-trip diagnostic informationwithout expensive networks.

PLC Level Auxiliary SwitchesA new family of gold flashed auxiliaryswitches for the FD through ND breakersallows sensing at very low voltage andcurrents for interface directly toprogrammable logic controllers and otherelectronic devices. Standard contacts,built to switch 120 Volts and highercurrents can be unreliable when the

sensing current is in the milliamp range,and the sensing voltage is 12 Volts orlower. These very reliable low levelswitches overcome that limitation.Standard switch contacts should, ofcourse, continue to be used in standardcurrent and voltage applications

DIN Rail mounted 120/240 V Breaker

Rotary Handle Operators for CQD

The Siemens BO breakers are nowavailable in 1 -and 2-pole construction,from 15 to 60 Amps in lug in - lug outDIN rail mounted configuration. Thesebreakers, rated 120/240 Volts, are idealfor applications in control panels andHVAC, and with their available finger safeterminal shields can qualify as servicedisconnects.

QJ Walking Beam Interlock

Answering the growing need for 120/240and 240 Volt standby power systems,Siemens introduces the walking beaminterlock for the QJ family of 240 Voltcircuit breakers. Useful in the cell towerand other commercial applications, theQJ walking beam allows interlocking two2 pole beakers mounted using only 4 polewidths, or two 3 pole breakers using 6pole widths. Please consult the factoryfor availability.

Both fixed and variable depth handleoperators are available for the CQDbreaker. These make the CQD aparticularly attractive product for use incontrol panels and similar configurations

Potter & Brumfield DiscontinuedWith SE&A's divestiture of SiemensElectromechanical Components, we haveceased offering the Potter & Brumfieldline of supplementary Protectors.

Enhanced SB ICCB

There have been several functionalenhancements to the SB SystemsBreaker since the last issue of theSpeedfax. These include:. Improved reliability, including regular

monthly breaker endurance testing to8,000 operations, a new ElectronicMotor Operator tested to 12,000operations, and improved secondarydisconnects

. Extended 2 Year Standard Warranty

Siemens Electrical Products SPEEDFAX 2000