Site Visit Report
The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where non-compliance against a particular condition has not been reported, this should not be construed to mean that there is full compliance with that condition of the licence.
Instructions and actions arising from the visit shall be addressed, or where applicable noted, by the licensee in order to ensure compliance, to improve the environmental performance of the installation and to provide clarification on certain issues.
The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.
Licensee
Name of Installation Anglo Beef Processors Ireland t/a ABP Proteins Waterford
Licensee Anglo Beef Processors Ireland Unlimited Company
Licence Register No. P0040-02
CRO Number 217122
Site Address Christendom, Ferrybank, Waterford, Waterford
Site Visit Reference No. SV16024
Report Detail
Issue Date 22/10/2018
Prepared By Victor Olmos
Site Visit Detail
Date Of Inspection 06/09/2018 Announced No
Time In 09:00 Time Out 17:00
Visited by on behalf of the EPA Exova Catalyst Ireland
Licensee Personnel and Role See report.
Photo Taken No Samples Taken Yes Video Taken No
Odour Assessment No
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 1 of 77
Scope
This is a technical report on the monitoring of emissions to atmosphere.
Media
Air.
Site Areas Inspected
See report.
Documents Inspected
See report.
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 2 of 77
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 3 of 77
UKAS ISO/IEC 17025 Accredited Testing Laboratory No. 4279Exova Environmental (UK) Ltd trading as Exova Catalyst & Exova Catalyst Ireland
Unit C5, Emery Court, The Embankment Business Park, Stockport, SK4 3GL
EMISSIONS REPORTEPA AIR EMISSIONS COMPLIANCE MONITORING
Exova Catalyst Ireland, Unit D8 North City Business Park, North Road, Finglas, Dublin 11E: patrick.obrien@exova.com
Your Exova Catalyst Ireland Contact: Patrick O'Brien (+353 86 416 1434)
FerrybankChristendom
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
EPA Office of Environmental Enforcement
A1-AEP1 - Biofilter
(Prepared on behalf of the EPA by Exova Catalyst - EPA Contract No. OEE-17-AEMP)-
-
Report Written byJames Magann
12th October 2018Report Date
TE1 TE2 TE3 TE4
Regional Manager
MM15 1330MCERTS Level 2
Deputy Regional Manager
TE1 TE2 TE3 TE4MM08 922
MCERTS Level 2
Donal O FaogainReport Approved by
Version
Stack Emissions Testing Report Commissioned by
6th - 7th September 2018
Job Reference NumberP0040-02-CAR18-01-A
Installation Name & Address
Dates of the Monitoring Campaign
Stack Reference
Industrial Emissions Licence: P0040-02
Signature of Report Approver
Version 2
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 4 of 77
TITLE PAGE
CONTENTS
EXECUTIVE SUMMARY
Monitoring Objectives
Monitoring Results
Monitoring Dates & Times
Process Details
Monitoring & Analytical Methods
Summary of Sampling Deviations
Sampling Location
Plant Photos / Sample Points
APPENDIX 1 - Monitoring Personnel & List of Equipment
APPENDIX 2 - Raw Data, Sampling Equations & Charts
The testing performed fully meets the technical requirements in Irish EPA Guidance Note, AG2.
Opinions and interpretations expressed herein are outside the scope of Exova Catalyst Ireland's ISO 17025 accreditation.
This test report shall not be reproduced, except in full, without the written approval of Exova Catalyst Ireland.
This version of the test report supersedes the previous version of the test report. Please destroy all previous versions to ensure no confusion arises from having multiple test reports in existence.
9
3
5
6
8
4
7
7
CONTENTS
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 2 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 5 of 77
Overall Aim of the Monitoring Campaign
Special Requirements
Target Parameters
Exova Catalyst Ireland were commissioned by the EPA Office of Environmental Enforcement to carry out stack emissions testing at Anglo Beef Processors (TA Munster Proteins Waterford) on the A1-AEP1 - Biofilter at Waterford.
The aim of the monitoring campaign was to demonstrate compliance with a set of emission limit values (ELVs) as specified in the Site's Licence.
There were no special requirements.
Ammonia, Mercaptans, Amines , Hydrogen Sulphide , Odour
MONITORING OBJECTIVES
Executive Summary(Page 1 of 7)
A1-AEP1 - Biofilter6th - 7th September 2018
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 3 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 6 of 77
where MU = Measurement Uncertainty associated with the Result
Parameter
Ammonia ¹ < .Mercaptans ¹ < .Amines ¹ < .Hydrogen Sulphide ¹ < .Water Vapour
¹ Reference Conditions (REF) are: 273K, 101.3kPa, without correction for water vapour content.
Parameter
Odour - Biofilter Odour ² .
Where CI stands for Confidence Interval (or Uncertainty associated with the result)
² Reference Conditions (REF) are: 293K, 101.3kPa, without correction for water vapour content
ouE/m³ 378 -CI
Result LOWER
% v/v- - #
---
#ppm
0.00094 50
Executive Summary
-
Limit+/-
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
6th - 7th September 2018
-Units -
-
Concentration
-
(Page 2 of 7)
--
-
MU-
MONITORING RESULTS
A1-AEP1 - Biofilter
ppm - #-
Result -
0.00460.015 #50.0031 -
ppm -1.93 0.39 -5ppm 1.25 0.13 5 -
0.49 0.026
CIUnits
- -77
RESULTS FROM ODOUR SAMPLES
Concentration -
-171
UPPER
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 4 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 7 of 77
Parameter
R1 < .R1 - .R1 < .R1 < .R1 .
All results are expressed at the respective reference conditions.
ppm 11:35 - 12:051.93
ppm
Date(s)--
Hydrogen Sulphide ouE/m³ 06/09/2018 10
-
0.0046 - 07/09/2018-
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
(Page 3 of 7)
MONITORING DATE(S) & TIMES
A1-AEP1 - Biofilter6th - 7th September 2018
Executive Summary
- minsSamplingConcentration Sampling
Ammonia - 10:12 - 10:42
-Times
Duration
ppm--
Odour - Biofilter
Units
0.015-
ppm -Mercaptans 11:02 - 11:3207/09/20183030
1.25Amines 3011:35 - 12:0507/09/2018
3007/09/201811:35 - 11:45171 --
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 5 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 8 of 77
Standard Operating Conditions
On
Continuous
Executive Summary
PROCESS DETAILS
Capacity (of 100%) and Tonnes / HourContinuous or Batch Process
NA
(Page 4 of 7)
Parameter
Process Status
NA
FuelNone
Full Capacity (100%)
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Abatement SystemAbatement System Running Status
Plume Appearance
Woodchip Biofilter
Value
Rendering Process
A1-AEP1 - Biofilter6th - 7th September 2018
Feedstock (if applicable)
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 6 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 9 of 77
CAT A1 ICCAT-TP-16 Yes
NoCEN/TS 13649
Lab Testing
NoIC
EN 14791
CAT-TP-16 Yes
ICCAT-TP-16
Hydrogen Sulphide
CAT
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
NoOL 2CAT-TP-30BS EN 13725OdourOdour
IrlYes No
Odour Ireland
Olfactometry
Yes 0.1 % v/vYesEN 14790
ANALYSIS LABORATORIES
ISO 17025 Accreditation Number: 4279ISO 17025 Accreditation Number: 1549
CAT-TP-05 CAT-TP-05 GravimetricWater Vapour CAT
(with short name reference as appears in the table above)
Exova Catalyst (CAT)
SUMMARY OF SAMPLING DEVIATIONS
RunParameter
Concept Life Sciences Ltd (CLS)RPS Laboratories Ltd (RPS) ISO 17025 Accreditation Number: 0605
Deviation
16 ouE/m³
RPS No
CAT
CAT
Yes
N/A
C28CEN/TS 13649
GCMSRPSCAT
1.249 ppm
YesAmines 1.932 ppm
RPSRPS
MercaptansA6 Yes
NoYes
CATYes
YesCAT-TP-140.004 ppm
0.006 ppm
CEN/TS 13649
Procedure (Average)
YesIn House
Ammonia
Standard ISO
Executive Summary
Analysis
Testing ISOAnalyticalTechnical MCERTSAnalyticalTechnique
MONITORING & ANALYTICAL METHODS
6th - 7th September 2018
Parameter
(Page 5 of 7)
LODLab17025
TestingProcedure
Analysis
Monitoring
A1-AEP1 - Biofilter
17025 Analysis
All There are no deviations associated with the sampling employed.All
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 7 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 10 of 77
Duct Characteristics Location of Sampling Platform
Platform Details
Sampling Location / Platform Improvement Recommendations
EN 15259 Homogeneity Test Requirements
Number of Ports - 1
Executive Summary
cm
-Type0.13
Width
Irish EPA Technical Guidance Note AG1 / EN 15259 Platform Requirements
Sample Port Size Hole
Value
Value
There are no obstructions present which hamper insertion of sampling equipment
Permanent / Temporary PlatformInside / Outside
Circular
Vertical
Yes
-
No
Yes
N/AN/A
SUITABILITY OF SAMPLING LOCATION
Outside
m²m
N/A
The sampling location meets all the requirements specified in Irish EPA Guidance Note AG1 and EN 15259, and therefore there are no improvement recommendations.
Parameter
There is no requirement to perform a EN 15259 Homogeneity Test on this Stack.
(Page 6 of 7)
Platform has chains / self closing gates at top of laddersPlatform has vertical base boards (approx. 0.25m high)Platform has 2 levels of handrails (approx. 0.5m & 1.0m high)
m
0.01
Orientation of Duct
N/A
Sufficient working area to manipulate probe and operate the measuring instruments
Value
0
Units General Platform Information
Safe Access Available
-
On Ground
-
Easy Access Available
Port Depth
Depth
Area
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 8 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 11 of 77
SAMPLE POINTS
PLANT PHOTOS
(Page 7 of 7)
Photo 1 Photo 2
Executive Summary
Line A
where = isokinetic point sampled at
= isokinetic point not sampled at
= combustion gases sample point
A1
= non-isokinetic sample point
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 9 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 12 of 77
APPENDIX 1 - Stack Emissions Monitoring Personnel, List of Equipment & Methods and Technical Procedures Used
APPENDIX 2 - Summaries, Calculations, Raw Data and Charts
APPENDICES
APPENDIX CONTENTS
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 10 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 13 of 77
Bioaerosols Temperature Logger -Electronic Refrigerator -
Stopwatch
- SELECT Horiba Model (2)SELECT Servomex Model -
Stack Thermocouple (2)
Amines
-
5m Heated Line (1) -
Ammonia
Hydrogen Sulphide
EN 14790
CEN/TS 13649 CAT-TP-16OdourWater Vapour
Position
Team Leader
-
-
-
-
MCERTS Level 1
Name
SELECT FTIR
MCERTS Number
Miscellaneous Items
-
-
Mercaptans
1m Heated Line (3)
Control Box DGM (1)
METHODS & TECHNICAL PROCEDURES USED
CAT 7.55Equipment Type Equipment Type
Control Box DGM (2)
-
James Magann MCERTS Level 2
SELECT Logger 2 -Dual Channel Heater Controller CAT 3.80500g / 1Kg Check Weights CAT 17.30
Last Impinger Arm CAT 4.005Callipers
-Umbilical (2) Testo 350 XL
MM17 1414MM15 1330
CAT 25.55
CEN/TS 13649
Parameter
-
Eco Physics CLD 822Mh
TE1 TE2 TE3 TE4
Site Balance
Ankersmid APP100
Instrumental Analysers
CAT 3.134-
Mass View (2)
1m Heated Line (1)-
-
STACK EMISSIONS MONITORING PERSONNEL
-
-
- 20m Heated Line (1)
Tubes Kit Thermocouple CAT 4.0005
20m Heated Line (2)
-
Single Channel Heater Controller
-
-
CAT 25.56
- 1m Heated Line (2)Heated Probe (2)
15m Heated Line (1)
CAT 17.30
-
Technical ProcedureStandard
Heated Probe (1)Bernath 3006 FID -
EN 14791
-
-
Technician Brian Walsh
Equipment I.D.
APPENDIX 1
Mass View (1)
CAT 4.715
Technical Endorsements
S-Pitot (1)
L-Pitot
Barometer
Digital Manometer (2)
Umbilical (1)Box Thermocouples (2)Box Thermocouples (1)
Mass Flow Controller (2)
Stack Thermocouple (1)
Gasmet Sampling SystemCAT 5.109
Extractive Sampling
LIST OF EQUIPMENT
MCERTS Accreditation
SELECT Logger 1
-
Oven Box (2)
CAT 3.134
TE1 & TE4
ABB AO2020-URAS26
Equipment I.D.
-
CAT 14.53
-
S-Pitot (2)
Equipment I.D.Digital Manometer (1)SELECT Horiba Model (1)
-
-
SELECT Gas Conditioning
CAT 13.39
Mass Flow Controller (1)
Digital Temperature Meter
Heated Probe (3) -
Stack Thermocouple (3)
-
Equipment Type
-
-
-
CEN/TS 13649
-Laboratory BalanceTape Measure CAT 16.95
CAT-TP-16CAT-TP-14
CAT-TP-05CAT-TP-30BS EN 13725
CAT-TP-16
Oven Box (1)
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 11 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 14 of 77
Sample Runs
- -
< <
- -
- -
- -
- -
Blank Runs
- -
< <
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Positioning of Filter Out Stack
Run 1
Absorption Solution 0.05 mol/l Sulphuric Acid
47mm Quartz Fibre
Maximum
1 / 1Number of Sampling Points Used 1 / 1
EN 14791
A1
Mean
Uncertainty
Water Vapour % v/v 0.47
Number of Sampling Lines Used
Probe Material TitaniumFilter Housing Material
Technical Procedure CAT-TP-14
±ppm 0.0009
Concentration
A1-AEP1 - Biofilter
Parameter Units
AMMONIA: RESULTS SUMMARY
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
±% v/v
Run 1
0.0009
Parameter Units
Value
0.01
Parameter
Parameter
Sample Point I.D.'s
TitaniumImpinger Material Borosilicate Glass
ppm
Standard
Filter Size and Material
Analytical Laboratory's Procedure
Date of Sample Analysis
RPS
Uncertainty
0.47
APPENDIX 2
24/09/2018
Units Blank 1
0.020.02
Yes
Name of Analytical Laboratory
Mean
Concentration ppm 0.0046
0.01
0.0046
A6ISO 17025 Accredited Analysis?
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 12 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 15 of 77
Sample Runs
<<--<<<<
Where: DGM stands for Dry Gas Meter
Blank Runs
<-<<
Volume in Impingers
DGM Yd -
DGM Start Temperature °C
µg/ml 0.10
DGM End Volume m³ 7.6960DGM Start Volume
Volume Sampled (STP, Wet) m³
ml 307.0
12.80
Total Mass Of Water Vapour
0.9490
Total Mass Collected
Laboratory Result for Impingers µg/ml
Liquid Trap Start Mass
Parameter
Mass in Front Impingers
m³ 1.4820
mmH₂OStart ∆H
Laboratory Result for Front Impingers µg/ml 0.10
0.10
µg 10.632.8
Volume in Back Impinger ml 106.0
End ∆H mmH₂O
Parameter Units Run 1
AMMONIA: SAMPLING DETAILS
APPENDIX 2
Calculated Concentration ppm 0.01
10:12 - 10:42
- 07/09/2018
g 20.3
Sampling Dates - 07/09/2018
Calculated Concentration ppm 0.01
l/min 196.57
1201.7
µg 22.2
- DGM
222.0
5.4008
Blank Dates
Barometric Pressure kPa 100.2
Total Mass Collected
DGM End Temperature °C
g
5.4008
Average Volume Sampled (REF) m³ 5.4008
µg 30.7
Volume Sampled (STP, Dry) m³
µg
Units
22.0
Liquid Trap End Mass g 1209.9
5.3755
Mass in Back Impinger
0.47
Silica Trap Start Mass g 894.9
-
30
25.0
12.60
Silica Trap End Mass g 907.0
Laboratory Result for Back Impinger
Sample Flow Rate
Duration mins
Blank 1
Volume in Front Impingers ml
Sampling Device
Sampling Times
Volume Sampled (REF) m³
Calculated Water Vapour % v/v
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 13 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 16 of 77
Sample Runs
² The concentration is less than 30% of the ELV, therefore no assessment against an allowable efficiency is required. 1 7 0 8
Blank Runs
Method Deviations
1
wx
- - - - -
- - - - -
- - - - -
Allowable Leak Rate l/min
0.02
YesMU Acceptable %
Post-Sampling Leak Rate l/min
Post-Sampling Leak Rate l/min 0.02
Test Conditions Units Run 1
Yes ²
- Yes
Absorption Efficiency Acceptable -
Water Droplets Units Run 1
Pre-Sampling Leak Rate l/min 0.01
Validity of Blank vs ELV Units Blank 1
ppm 5.0
0.20
% 20.0
Expected Sampling Rate l/min 10.0
Yes
Leak Test Acceptable - Yes
Allowable Blank
Ambient Temperature Recorded?
Nature of Deviation Run Number(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)
There are no deviations associated with the sampling employed.
Allowable MU
% Yes
-
Allowable Absorption Efficiency %
Blank Acceptable
Leak Test Results
Leak Test Acceptable - Yes
MU (Concurrent Water Vapour) Units Run 1
l/min 0.02
100.0
APPENDIX 2
AMMONIA: QUALITY ASSURANCE
Leak Test Results Units Run 1
Absorption Efficiency
Measurement Uncertainty (MU) % 5.3
Absorption Efficiency Units
%
Are Water Droplets Present - No
Less than 50% Faded
Run 1
N/A ²
Units Blank 1
Silica Gel (Concurrent Water Vapour) Units Run 1
Allowable Leak Rate l/min 3.93
Mean Sampling Rate l/minPre-Sampling Leak Rate
196.6
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 14 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 17 of 77
Sampled Volume (Actual)Sampled Gas TemperatureSampled Gas PressureSampled Gas HumidityLeakLaboratory Result
Sampled Volume (Actual)Sampled Gas TemperatureSampled Gas PressureSampled Gas HumidityLeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
O₂ Correction FactorStack Gas O₂ ContentMU for O₂ Correction
Combined uncertainty
Expanded uncertainty (95% confidence), without Oxygen CorrectionExpanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported Uncertainty
Expanded uncertainty (95% confidence), without Oxygen CorrectionExpanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported Uncertainty
%
%
ppm
Uncertainty in Result
N/A
-
Measured Quantities
≤2%%
0.1243
ppmLr
1.0
Vm m³ 5.3755
-
- N/A
ppm
%
Run 1
Parameter
Symbol Run 1
uρm kPa 0.5
L ppm
0.00000
10.00
1.00
≤2%
ppm 0.0005
Lr 10.00
0.00
uLr
≤1%%
2.00
%
Uncertainty as a Percentage
K
% 20.3
Units Run 1
N/A
Units Run 1
Symbol
ppm
Measured Quantities
uVm
0.0001.00
Oxygen Correction Part of MU Budget
% v/v
1.00
0.000
Hm 0.0%
Units
uL
Measured Quantities
N/A
-
Run 1
0.67
Measured Quantities Units Run 1
ppm N/A
20.3
ppm
%
N/A
0.0009
Overall MU For O₂ Measurement
Uncertainty in Measurement Units Sensitivity Coefficient
6.2140
0.0005
L 0.01
Tm
Symbol Units Run 1Measured Quantities
Vm
0.0009
20.3
ppm
ppm 0.00012
≤1%%
Run 1
%
Units
0.0009
296.5
No Requirement
uTm
0.01
%
m³2.0
0.50≤1%
uHm % v/v
APPENDIX 2
AMMONIA: MEASUREMENT UNCERTAINTY CALCULATIONS
Value Standard uncertainty
ρm 100.2
Requirement of Standard
%
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 15 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 18 of 77
Sample Runs
- -
- -
- -
- -
- -
- -
Blank Runs
- -
- -
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference ConditionsReference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
0.002
Units Run 1
% v/v 0.50
0.003
ppm
Parameter Value
Titanium
1 / 1
Parameter Units Blank 1 Maximum
Parameter Units Run 1
0.002
±ppm 0.003
0.015
Mean
CAT-TP-16
0.50
ppm 0.015
Standard
Water Vapour
MERCAPTANS: RESULTS SUMMARY
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Concentration
Uncertainty
Analytical Laboratory's Procedure In House
A1-AEP1 - Biofilter
Parameter
A1
Uncertainty ±% v/v
Mean
Absorption Solution
Parameter Molecular Weightbutyl mercaptan 90.19
All of the results were < LOD for the mercaptan suite (butyl, ethyl & methyl mercaptans). The molecular weight for butyl mercaptan was used to convert the results to ppm.
Impinger Material Borosilicate Glass
Filter Housing Material
Number of Sampling Lines Used
Positioning of Filter
Titanium
Sample Point I.D.'s
Out StackFilter Size and Material
0.03
RPS
Concentration
CEN/TS 13649Technical Procedure
No
Name of Analytical Laboratory
APPENDIX 2
1 / 1
Treated Filter
Number of Sampling Points Used
ISO 17025 Accredited Analysis?
0.03
21/09/2018
Treated Filter
Date of Sample Analysis
Probe Material
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 16 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 19 of 77
Sample Runs
--------
Where: DGM stands for Dry Gas Meter
Blank Runs
----
5.2114
10.0
Average Volume Sampled (REF) m³
Parameter Units
0.002
g
mmH₂O
30
10.00
Volume Sampled (STP, Dry)
Silica Trap Start Mass
1.0
Sample Flow RateVolume Sampled (REF)
Volume in Back Impinger
0.9490
Blank 1
Silica Trap End Mass
Liquid Trap Start Mass
µgMass in Front Impingers
10.00
-
DGM Yd -
5.2114
25.0
10.0
Total Mass Of Water Vapour g
12.60
Calculated Water Vapour % v/v 0.50
µg/ml
Total Mass Collected
20.0
ml
Volume Sampled (STP, Wet) m³ 5.2114
Volume in Front Impingers1.0
m³
Laboratory Result for Front Impingers µg/ml 10.00
Start ∆H
Duration mins
07/09/2018
DGM End Temperature
DGM Start Volume m³
Sampling Device
°C
-Sampling Dates- DGM
11:02 - 11:32
DGM Start Temperature
Mass in Back Impinger µg 10.0
1.0
MERCAPTANS: SAMPLING DETAILS
m³l/min
Parameter Units
8.2450
ppm
1542.2
Volume in Impingers
21.0
µg
Blank Dates
Calculated Concentration
ml
07/09/2018
Laboratory Result for Impingers
186.64
Total Mass Collected µg
DGM End Volume m³ 14.1450
ml
Run 1
°C
APPENDIX 2
Laboratory Result for Back Impinger µg/ml
gLiquid Trap End Mass g 4332.2
5.1853
4330.2
12.80
Calculated Concentration ppm 0.00
Barometric Pressure kPa 101.8
End ∆H mmH₂O
g 1523.2
22.0
Sampling Times -
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 17 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 20 of 77
Sample Runs
0 7 0 7
Blank Runs
Method Deviations
1
wx
- - - - -
- - - - -
- - - - -
(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)
There are no deviations associated with the sampling employed.
l/minExpected Sampling Rate 10.0
Nature of Deviation
Allowable Leak Rate
Blank Acceptable
%
Yes
l/min 0.20
Test Conditions
%
Silica Gel (Concurrent Water Vapour) Units
-
Leak Test Results Units Run 1
Pre-Sampling Leak Rate l/min
Units
%
ppm
Run 1
Post-Sampling Leak Rate
0.5
Units
APPENDIX 2
MERCAPTANS: QUALITY ASSURANCE
Allowable Blank
-
Yesl/min
Pre-Sampling Leak Rate l/min 0.02186.6
Post-Sampling Leak Rate
l/min 0.03
Leak Test Results
0.03
Blank 1
No
l/min
-
Absorption Efficiency
-
Run Number
Validity of Blank vs ELV Units Blank 1
Yes
Run 1
MU Acceptable
0.01
% YesAllowable MU
Yes
Water Droplets
MU (Concurrent Water Vapour)
Measurement Uncertainty (MU)
3.73Leak Test Acceptable
Ambient Temperature Recorded?
l/min
Units
5.3
N/A
Leak Test Acceptable
Allowable Absorption Efficiency
Less than 50% Faded
-
Units Run 1
20.0
- Yes
Absorption Efficiency
Are Water Droplets Present
Absorption Efficiency Acceptable
Run 1
Units
Allowable Leak Rate
%N/A
Run 1
Mean Sampling Rate
%
50.0
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 18 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 21 of 77
Sampled Volume (Actual)Sampled Gas TemperatureSampled Gas PressureSampled Gas HumidityLeakLaboratory Result
Sampled Volume (Actual)Sampled Gas TemperatureSampled Gas PressureSampled Gas HumidityLeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
O₂ Correction FactorStack Gas O₂ ContentMU for O₂ Correction
Combined uncertainty
Expanded uncertainty (95% confidence)Expanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported Uncertainty
Expanded uncertainty (95% confidence)Expanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported Uncertainty
m³
% v/v
Run 1
uTmTm
Requirement of Standard
%
≤1%
Units
≤1%
%
Value
ppm
0.0004
MERCAPTANS: MEASUREMENT UNCERTAINTY CALCULATIONS
-
≤2%
L
Lr 10.00
0.1180
Symbol
Units Run 1
uρm kPa
≤2%
Lr ppm
uLr %
ρm
Vm
Measured Quantities
Measured Quantities
0.0015
Measured Quantities
Run 1
Standard uncertainty
0.0015
101.8
0.0030
Measured Quantities
Run 1
ppm
% 10.00
uL % -
5.9000
Units
APPENDIX 2
% N/A
ppm 0.00
20.3
Symbol
0.5
Uncertainty as a Percentage
Run 1
1.0L 0.01
Hm
ppm
UnitsParameter
0.0
Symbol Run 1
296.5
Sensitivity Coefficient
5.1853
N/A-
m³
0.0000
Units
N/A
0.49
N/A
% 0.01
-
% 1.00
20.3
0.00
K 2.0
uVm
Uncertainty in Result
Units
Measured Quantities
Overall MU For O₂ Measurement
2.00
N/A
%
0.67 ≤1%
No Requirement
1.00
0.0000ppm
%
0.0016
ppm
ppm
% 20.3
%
0.0031
% v/v N/A
Oxygen Correction Part of MU Budget
ppm
Run 1
Uncertainty in Measurement Units
Run 1
1.00
%
ppm
Vm
uHm
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 19 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 22 of 77
Sample Runs
- -
< << << << << << <
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Sample Point I.D.'s A1
Probe Material Titanium
Dynamic Dilution Employed
Number of Sampling Points UsedNumber of Sampling Lines Used 1 / 1
Standard
0.440.22 0.22
ppm 0.42
ppm
CEN/TS 13649
Total 1.93
No
MethylamineTrimethylamine
Technical Procedure CAT-TP-16
ppmppmppm
0.32DimethylamineEthanolamine
APPENDIX 2
Analytical Laboratory's Procedure C28ISO 17025 Accredited Analysis? See Executive SummaryDate of Sample Analysis 24/09/2018
0.52
Parameter
AMINES : RESULTS SUMMARY
Mean
A1-AEP1 - Biofilter
0.42
0.32
Parameter
0.44
Units Run 1
Sample Tube Type Silica Gel
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Value
Name of Analytical Laboratory RPS
1 / 1
0.52Diethylamine
ppm 1.93
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 20 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 23 of 77
Where: MV stands for Mass View (Mass Flow Controller Technology)
< < - < << < - < << < - < << < - < << < - < <
- < <
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Tube Lot Number and Unique ID: 1011604
DiethylamineDimethylamineEthanolamineMethylamineTrimethylamine
Parameter Molecular Weight73.1445.0861.0831.1
59.11
AG2 Reporting Format ELV (ppm) Results (ppm) Breakdown of Results Exceedance?
Amines 5 > 0 and < 1.93 > (sum of ) and < (sum of 1+2+3+4+5) -
-
LOD (Front)
µg
LOD (Back)
µg
0.323 0.323 0.323 100.02.0
1.0 1.0 2.0 1.01.0
1.01.0
Lab Result (Front)
µg
2.0
2.0 0.424 0.424 0.424 100.0
Lab Result (Back)
µg
Ethanolamine1.0
N₂ to Stack Gas Dilution Ratio
- 07/09/2018
1.0
Parameter LOD (Total)
µg
AMINES : SAMPLING DETAILS
Value
Sampling Dates-
Lab Result (Total)
µg
1.0
1.01.0
1.0
Sampling Times
Duration 30
10.0
Diethylamine
10.0 1.932 1.932Trimethylamine
1.932Total
APPENDIX 2
1.0 2.0
0
1.0
Dimethylamine 1.0 2.0
Units
1.0 2.0
Sampling Device
2.0
0.438 0.4380.2230.223
Adsorption Efficiency
%
Parameter
0.223 100.0100.0
0.524
-
0.4381.02.0
1.0 0.524
Reported LOD ppm
1.0 0.524 100.0
1.0 2.0
MV
Volume Sampled (REF) m³ 0.0124
RUN 1
Reported Concentration
(Blank Reviewed) ppm
11:35 - 12:05
: 1mins
Concentration ppm
Methylamine
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 21 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 24 of 77
Where: MV stands for Mass View (Mass Flow Controller Technology)
< < - << < - << < - << < - << < - <
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Tube Lot Number and Unique ID: 1011603
Sampling Dates -
2.0
2.0 5.8881.0 1.0
1.0
1.0
2.0 2.334Ethanolamine
Lab Result (Total)
µg
1.0
Concentration ppm
1.0 2.0 0.524Dimethylamine 1.0 1.0
10.9732.0 4.386
Trimethylamine 1.0
Parameter Lab Result (Front)
µg
Lab Result (Back)
µg
APPENDIX 2
07/09/2018
AMINES : SAMPLING DETAILS
BLANK 1
Parameter Units Value
Sampling Device - MVAverage Volume Sampled (REF) m³ 0.0124
Diethylamine
Methylamine1.0
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 22 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 25 of 77
Sample Runs
Run 1
Adsorption Efficiency Units
Mean Sampling Rate
°C
Allowable Temperature
Test Conditions Units
Allowable Leak Rate
Run 1
95Adsorption Efficiency AcceptableAllowable Adsorption Efficiency
14
%-
0.2l/min
0.00Post-Sampling Leak Rate
Diethylamine %
-Leak Test Acceptable
0.00
0.01
Run 1
l/min
Yesl/min
AMINES : QUALITY ASSURANCE
Pre-Sampling Leak Ratel/min
APPENDIX 2
Leak Test Results Units
Yes
Run 1
Yes
Temperature at Sample Tubes Units
Yes
-Ambient Temperature Recorded?
Temperature Acceptable -
(PAGE 1 OF 2)
100.0
Temperature40°C
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 23 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 26 of 77
Blank Runs
Method Deviations
1
x
- - - - -
- - - - -
- - - - -
l/min 0.2
Validity of Blank vs ELV Units
Allowable Leak Rate
Run Number
There are no deviations associated with the sampling employed.
Allowable for TOTAL
(x = deviation applies to the associated run)
34.9
Nature of Deviation
ppm 0.5
ppm
Leak Test Acceptable
Leak Test Results
N/A
N/A
APPENDIX 2
AMINES : QUALITY ASSURANCE
0.5
Blank 1
Allowable for Dimethylamine
4.4
N/A
11.0 N/A
l/min
N/A
(PAGE 2 OF 2)
Allowed
l/min
Units
Expected Sampling Rate
5.9Allowable for Ethanolamine ppmppmppm
Blank 1
0.01
Allowable for MethylamineAllowable for Trimethylamine
Allowable for Diethylamine
0.00
2.3ppm
-
Sampling Leak Rate
Yes
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 24 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 27 of 77
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
O₂ Correction FactorStack Gas O₂ ContentMU for O₂ Correction
Combined uncertainty
Expanded uncertainty (95% confidence), without Oxygen CorrectionExpanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported Uncertainty
Expanded uncertainty (95% confidence), without Oxygen CorrectionExpanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported UncertaintyNOTE: Uncertainties reported in ppm are based upon the summation of all Speciated VOCs Measured.
Run 1
%
Measured Quantities
156.00
Sensitivity Coefficient
Uncertainty in ResultRun 1
m³
ppm 0.197
N/A
0.386
0.1932
- N/A
Units
20.0
Units
Symbol Units
% v/v
20.0
0.193L ppm
uL
Vm
Run 1
ppm
Units
0.0124
1.00
uLr
Symbol
2.00
Measured Quantities
0.00
L0.0002
0.039
%
ppm
Run 1
≤5%
Run 1
ppm 0.0000
≤2%
-0.00
Run 1
AMINES : MEASUREMENT UNCERTAINTY CALCULATIONS
ValueMeasured Quantities Symbol
Units
1.00
APPENDIX 2
10.00%
Vm uVm m³
ppm
0.386
No Requirement
Uncertainty as a Percentage
ppm
%
N/A-
Requirement of Standard
Lr %
0.386
%
-
Standard uncertainty
Run 1
0.0124
% 10.00
Uncertainty in Measurement Units
ppm
ppm
%% N/A
N/A
Lr
0.000
Measured Quantities
20.0
Oxygen Correction Part of MU BudgetMeasured Quantities Units Run 1
%
ppm N/A
Parameter
Overall MU For O₂ Measurement
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 25 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 28 of 77
Sample Runs
- -
< <
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Name of Analytical Laboratory
HYDROGEN SULPHIDE : RESULTS SUMMARY
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Titanium
APPENDIX 2
MeanRun 1
Sample Point I.D.'s
Dynamic Dilution Employed
1 / 1
Value
1.25
Parameter
24/09/2018
Number of Sampling Lines UsedNumber of Sampling Points Used 1 / 1
Orbo
A1
RPSAnalytical Laboratory's Procedure A1ISO 17025 Accredited Analysis? See Executive Summary
No
Technical Procedure CAT-TP-16
ppm
Date of Sample Analysis
Probe Material
A1-AEP1 - Biofilter
Parameter
Sample Tube Type
Standard CEN/TS 13649
Hydrogen Sulphide
Units
1.25
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 26 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 29 of 77
Where: MV stands for Mass View (Mass Flow Controller Technology)
< < - < <
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Tube Lot Number and Unique ID: 1011606
Reported LOD ppm
Adsorption Efficiency
%
Hydrogen Sulphide 5.0 10.0 5.0 100.05.0 5.0
Lab Result (Back)
µg
1.249 1.249 1.249
Lab Result (Total)
µg
- MV
LOD (Back)
µg
10.0
LOD (Total)
µg
Concentration ppm
Parameter Lab Result (Front)
µg
: 1 0Duration mins 30N₂ to Stack Gas Dilution Ratio
APPENDIX 2
LOD (Front)
µg
11:35 - 12:05-
Sampling DeviceSampling Dates - 07/09/2018
Volume Sampled (REF)
Reported Concentration
(Blank Reviewed) ppm
m³ 0.0122
HYDROGEN SULPHIDE : SAMPLING DETAILS
RUN 1
Parameter
Sampling Times
Units Value
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 27 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 30 of 77
Where: MV stands for Mass View (Mass Flow Controller Technology)
< < - <
Reference Conditions are: 273K, 101.3kPa, without correction for water vapour content.
Tube Lot Number and Unique ID: 1011605
Lab Result (Back)
µg
Lab Result (Total)
µg
Concentration ppm
5.0 10.0 1.249
APPENDIX 2
HYDROGEN SULPHIDE : SAMPLING DETAILS
BLANK 1
Parameter Units Value
Sampling Dates - 07/09/2018Sampling Device - MVAverage Volume Sampled (REF) m³ 0.0122
Parameter Lab Result (Front)
µg
Hydrogen Sulphide 5.0
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 28 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 31 of 77
Sample Runs
Allowable Adsorption Efficiency % 95
Temperature
Temperature Acceptable -°C 40°C 14
Temperature at Sample Tubes Units Run 1
Yes
Test Conditions Units Run 1
Ambient Temperature Recorded? - Yes
Adsorption Efficiency Acceptable - Yes
Allowable Temperature
APPENDIX 2
HYDROGEN SULPHIDE : QUALITY ASSURANCE(PAGE 1 OF 2)
Leak Test Results Units Run 1
Mean Sampling Rate l/min 0.4Pre-Sampling Leak Rate l/min 0.00
Run 1
% 100.0
Post-Sampling Leak Rate l/min 0.00Allowable Leak Rate l/min 0.02Leak Test Acceptable - Yes
Adsorption Efficiency Units
Hydrogen Sulphide
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 29 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 32 of 77
Blank Runs
Method Deviations
1
x
- - - - -
- - - - -
- - - - -
Nature of Deviation
There are no deviations associated with the sampling employed.
Allowable for TOTAL ppm
Run Number(x = deviation applies to the associated run)
0.4
Blank 1
l/min 0.00
1.2 N/A
Leak Test Acceptable
Expected Sampling Rate l/min
Yes
Validity of Blank vs ELV Units
Allowable for Hydrogen Sulphide ppm
Blank 1 Allowed
1.2 0.5
Sampling Leak Rate
APPENDIX 2
HYDROGEN SULPHIDE : QUALITY ASSURANCE(PAGE 2 OF 2)
Leak Test Results Units
-Allowable Leak Rate l/min 0.02
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 30 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 33 of 77
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
Sampled Volume (STP)LeakLaboratory Result
O₂ Correction FactorStack Gas O₂ ContentMU for O₂ Correction
Combined uncertainty
Expanded uncertainty (95% confidence), without Oxygen CorrectionExpanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported Uncertainty
Expanded uncertainty (95% confidence), without Oxygen CorrectionExpanded uncertainty (95% confidence), with Oxygen CorrectionExpanded uncertainty (95% confidence), estimated with Method DeviationsReported UncertaintyNOTE: Uncertainties reported in ppm are based upon the summation of all Speciated VOCs Measured.
Measured Quantities
N/A
Parameter Units Run 1
ppmppm 0.132ppm
% 10.6
Units
0.0000
uLr % -
≤5%% 5.00
Measured Quantities
Measured QuantitiesValue
Symbol Units
Measured Quantities Units Run 1
ppm 0.0625
≤2%%
Units Run 1
0.00
0.00
Sensitivity Coefficient
Symbol
Vm 0.0121
Run 1
0.062 1.00
Uncertainty as a Percentage
APPENDIX 2
uL % -Lr 5.00
% 2.00
Run 1
HYDROGEN SULPHIDE : MEASUREMENT UNCERTAINTY CALCULATIONS
Measured Quantities Symbol Units Run 1
L ppm 0.000
uVm m³ 0.0002
Requirement of Standard
0.0121
ppm 0.025
- N/A
Uncertainty in Measurement Units
1.00Lr ppm
Vm m³
% v/v N/A
Oxygen Correction Part of MU Budget
% 10.6
ppm
% 10.6
ppm
Standard uncertainty
L
ppm
N/A
No Requirement
0.132
Run 1
0.067
103.08
Uncertainty in Result
Run 1
-
0.132
N/AOverall MU For O₂ Measurement % N/A
%
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 31 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 34 of 77
Results Summary
- -
- -- -- -
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 293K, 101.3kPa, without correction for water vapour content
Sampling & Result Information
Analysis Result including Dilution Factor
ID of Olfactometer -Calculated Panel Threshold ouE/m³ -Reference Odourant Used -Accepted Reference Value Used ppb -
25⁰C ± 3⁰CN/A
n-butanol in N₂
Analysis Result from Laboratory ouE/m³ 171
171ouE/m³
Units
No
1 / 1
0.14
Technical Procedure
77.46
Oxygen Content of the Stack Gas
Parameter
Duration mins 10
171.00
Units GEO Mean
Concentration ouE/m³ 171.00
Parameter
Number of Sampling Lines Used
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Bag 1
N/A
Biof
ilter
Stainless Steel
Date of Olfactometric Measurement - 06/09/2018
ouE/m³ 77.46
Parameter Bag 1
% v/v N/A
Sampling Dates - 06/09/2018
Sampling Times
% v/v
Sample ID
N/A
APPENDIX 2
ODOUR: RESULTS SUMMARY
: 1
-CDU-1092 BIO
RUN
Calculated Dilution Factor
ouE/m³
Number of Sampling Points Used
Release Point 1 - Biofilter
A1
377.74
1 / 1
Sample Point I.D.'s
CAT-TP-30
Probe Material
377.74Upper CILower CI
Temperature of Olfactometric Lab -
Value
Standard BS EN 13725
- 11:35 - 11:45
Odour Presentation Mode Yes / NoEquipment Used Odour BarrelCalibration Status of Olfactometer
Times of Ofactometric Measurement - 14:35
Special Process Conditions -
Oxygen Content of the Odour Bag
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 32 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 35 of 77
Method Deviations
1
x
- - - - -
- - - - -
- - - - -
APPENDIX 2
ODOUR: METHOD DEVIATIONS
Anglo Beef Processors (TA Munster Proteins Waterford), WaterfordAll Release Points
(x = deviation applies to the associated bag/s)
There are no deviations associated with the sampling employed.
Nature of Deviation Bag Numbers
Anglo Beef Processors (TA Munster Proteins Waterford)WaterfordA1-AEP1 - Biofilter
CAT-RT (Version BY)Page 33 of 33
Job Number: CDU-1092, Version 2Industrial Emissions Licence: P0040-02
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 36 of 77
UKAS ISO/IEC 17025 Accredited Testing Laboratory No. 4279
Exova Environmental (UK) Ltd trading as Exova Catalyst & Exova Catalyst Ireland
Unit C5, Emery Court, The Embankment Business Park, Stockport, SK4 3GL
Stack Emissions Testing Report Commissioned by
6th - 7th September 2018
Job Reference Number
P0040-02-CAR18-01-B
Installation Name & Address
Dates of the Monitoring Campaign
Stack Reference
Industrial Emissions Licence: P0040-02
Signature of Report Approver
Version 1
Version
Report Written by
James Magann
5th October 2018Report Date
TE1 TE2 TE3 TE4
Team Leader
MM15 1330MCERTS Level 2
Deputy Regional Manager
TE1 TE2 TE3 TE4MM08 922
MCERTS Level 2
Donal O Faogain
Report Approved by
(Prepared on behalf of the EPA by Exova Catalyst - EPA Contract No. OEE-17-AEMP)-
-
Exova Catalyst Ireland, Unit D8 North City Business Park, North Road, Finglas, Dublin 11E: patrick.obrien@exova.com
Your Exova Catalyst Ireland Contact: Patrick O'Brien (+353 86 416 1434)
FerrybankChristendom
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
EPA Office of Environmental Enforcement
EPA AIR EMISSIONS COMPLIANCE MONITORING
Thermal Oxidiser
EMISSIONS REPORT
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 37 of 77
TITLE PAGE
CONTENTS
EXECUTIVE SUMMARY
Monitoring Objectives
Monitoring Results
Monitoring Dates & Times
Process Details
Monitoring & Analytical Methods
Summary of Sampling Deviations
Sampling Location
Plant Photos / Sample Points
APPENDIX 1 - Monitoring Personnel & List of Equipment
APPENDIX 2 - Raw Data, Sampling Equations & Charts
7
CONTENTS
5
6
8
4
9
3
7
Opinions and interpretations expressed herein are outside the scope of
Exova Catalyst Ireland's ISO 17025 accreditation.
This test report shall not be reproduced, except in full, without the written
approval of Exova Catalyst Ireland.
The testing performed fully meets the technical requirements in Irish EPA
Guidance Note, AG2.
CAT-RT (Version BY)
Page 2 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 38 of 77
Overall Aim of the Monitoring Campaign
Special Requirements
Target Parameters
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
(Page 1 of 7)
Thermal Oxidiser
6th - 7th September 2018
Sulphur Dioxide, Total VOCs (as Carbon), Oxides of Nitrogen (as NO₂), Carbon Monoxide, Odour
MONITORING OBJECTIVES
Executive Summary
Exova Catalyst Ireland were commissioned by the EPA Office of Environmental Enforcement to carry out stack emissions testing at
Anglo Beef Processors (TA Munster Proteins Waterford) on the Thermal Oxidiser at Waterford.
The aim of the monitoring campaign was to demonstrate compliance with a set of emission limit values (ELVs) as specified in the
Site's Permit.
There were no special requirements.
CAT-RT (Version BY)
Page 3 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 39 of 77
where MU = Measurement Uncertainty associated with the Result
Parameter
Sulphur Dioxide ¹ - -
Total VOCs (as Carbon) ¹ - -
Oxides of Nitrogen (as NO₂) ¹ - -
Carbon Monoxide ¹ - -
Carbon Dioxide Dry
Oxygen* Dry
Water Vapour
Stack Gas Temperature
Stack Gas Velocity
¹
- - - - - - - - - - - -NOTE: VOLUMETRIC FLOW RATE & VELOCITY DATA TAKEN FROM THE PRELIMINARY VELOCITY TRAVERSE.
¹ Reference Conditions (REF) are: 273K, 101.3kPa, dry gas, 17% oxygen.
*Average oxygen concentration taken from all sampling runs, the O2 results for individual parameters can be found in Appendix 2.
Parameter
Odour - TO Odour ²
Where CI stands for Confidence Interval (or Uncertainty associated with the result)
² Reference Conditions (REF) are: 293K, 101.3kPa, without correction for water vapour content
-
-
0.26
-
-
2453
UPPER
RESULTS FROM ODOUR SAMPLES
Concentration
3457
0.09
Units
0.14
Volumetric Flow Rate (REF)
% v/v
mg/m³ 208.29
12.110.12
10.2
mg/m³
m³/hr
73596
g/hr
15.27- g/hr
139.47
% v/v
ouE/m³ 117
CI
Result Limit
mg/m³ g/hr -1.79
Volumetric Flow Rate (ACTUAL)
CI
m/s
0.1
265.5
m³/hr
6.71
6051
2.1
128814
0.18
8.17
°C
g/hr
-
0.29 -
Units
18.54
MU
MONITORING RESULTS
Thermal Oxidiser
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
6th - 7th September 2018
+/-
Units Result
Concentration
MU
(Page 2 of 7)
0.01 -
Executive Summary
Mass Emission
Limit
+/-
26830.59 1641.99
38.31mg/m³
% v/v
0.13
1.08
Result LOWER
Limit
-
8.45
CAT-RT (Version BY)
Page 4 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 40 of 77
Parameter
R1 - -
R1 - -
R1 - -
R1 - -
R1 -
R1 -
R1
R1
All results are expressed at the respective reference conditions.
3012:25 - 13:25
% v/v
#VALUE! 13:00 - 13:1053
mg/m³ 30
12:25 - 13:25
Oxides of Nitrogen (as NO₂)
0.09 60Total VOCs (as Carbon)
g/hr
g/hr
12:25 - 13:2526830.6208.3
mg/m³
8.45
12.11
6.58
139.5mg/m³Carbon Monoxide
12:25 - 13:25Oxygen 06/09/2018
Carbon Dioxide
1.1 30
% v/v
12:25 - 13:2506/09/2018
30
06/09/2018
06/09/2018
g/hr
30
Units Units
Times
Duration
(Page 3 of 7)
Odour - TO
18.54 12:45 - 13:15Sulphur Dioxide
SamplingConcentration Sampling
mins
Thermal Oxidiser
6th - 7th September 2018
Executive Summary
MONITORING DATE(S) & TIMES
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
06/09/2018g/hr0.14
06/09/2018
06/09/2018 10ouE/m³
10:12 - 10:22Velocity Traverse 06/09/2018
Date(s)
Mass Emission
mg/m³
CAT-RT (Version BY)
Page 5 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 41 of 77
Standard Operating Conditions
Not Visible
0
Thermal Oxidiser
6th - 7th September 2018
Feedstock (if applicable)
Thermal Oxidiser
Value
Capacity (of 100%) and Tonnes / Hour
Continuous or Batch Process
N/A
(Page 4 of 7)
Parameter
Process Status
N/A
Fuel
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Abatement System
Abatement System Running Status
Plume Appearance
N/A
N/A
Continuous
Executive Summary
PROCESS DETAILS
CAT-RT (Version BY)
Page 6 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 42 of 77
CAT-TP-39
All
Pitot Tube and Thermocouple
There are no deviations associated with the sampling employed.
Technique
Analytical
MONITORING & ANALYTICAL METHODS
6th - 7th September 2018
Parameter
(Page 5 of 7)
LODAnalytical
Monitoring
Thermal Oxidiser
Analysis
Lab17025
Testing
Procedure
Testing ISO
(Average)
ISO
Executive Summary
Procedure
Analysis
YesCAT-TP-09 0.001 mg/m³YesCATCAT-AP-01YesSulphur Dioxide ICCAT
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
17025 Analysis
Technical MCERTSStandard
Carbon Dioxide
CAT-TP-39
Velocity & Vol. Flow Rate
Yes
CAT
Water Vapour CAT
CAT
Yes
Deviation
SUMMARY OF SAMPLING DEVIATIONS
Odour Ireland
Yes
Exova Catalyst (CAT)
ISO 12039
CAT-TP-05
Yes CAT
Yes
0.1 %
No
All
EN 16911-1 (MID) CAT-TP-41
Flame Ionisation Detection by Sick 3006 FID
16 ouE/m³
NDIR by Horiba PG-350E
0.32 %
Yes Yes
EN 14789 CAT-TP-39 Yes
ISO 17025 Accreditation Number:
Yes
Total VOCs (as Carbon)
CAT
Oxides of Nitrogen (as NO₂)
Gravimetric
NDIR by Horiba PG-350E
CAT-TP-20 YesEN 12619:2013
EN 14792
CAT 0.32 mg/m³
Chemiluminescence by Horiba PG-350E
Yes 0.36 mg/m³CAT
Run
Yes
ANALYSIS LABORATORIES
ISO 17025 Accreditation Number: 4279
ISO 17025 Accreditation Number: 0605
Dry Paramagnetic Cell by Horiba PG-350E YesOxygen
Parameter
RPS Laboratories Ltd (RPS)
Carbon Monoxide EN 15058
YesEN 14790
1.2 m/s
(with short name reference as appears in the table above)
CAT
NoOL 2
CAT-TP-39
Olfactometry
Yes 0.1 % v/vCAT-TP-05
CAT-TP-30BS EN 13725Odour SIL
0.41 mg/m³
Yes
CAT
EN 14791
Lab Testing
CAT-RT (Version BY)
Page 7 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 43 of 77
Duct Characteristics Location of Sampling Platform
Platform Details
Sampling Location / Platform Improvement Recommendations
EN 15259 Homogeneity Test Requirements
Sampling Plane Validation Criteria (from EN 15259)
: 1 Yes
< 15°- -
Depth
Highest Gas Velocity
Area
°
-
Lowest Differential Pressure
Port Depth
Criteria in EN 15259
Permanent
-
-
-
Yes
-
-
- -
Easy Access Available
Yes
-
-
Safe Access Available
-
-
-
-
- -10.17
< 3 : 1Ratio of Above
-
--m/s
Maximum Angle of Swirl
m
2.01
Orientation of Duct
7
Units General Platform Information
-
> 5 Pa
The sampling location meets all the requirements specified in Irish EPA Guidance Note AG1 and EN 15259, and therefore there are
no improvement recommendations.
Parameter
There is no requirement to perform a EN 15259 Homogeneity Test on this Stack.
(Page 6 of 7)
-
Platform has chains / self closing gates at top of ladders
Platform has vertical base boards (approx. 0.25m high)
No Local Negative Flow
Sample Port Size
Yes
-
9.38
-
-
Required
-
-
N/A
4" BSP
-
Sufficient working area to manipulate probe and operate the measuring instruments
Value
m²
m
Yes
Width
Irish EPA Technical Guidance Note AG1 / EN 15259 Platform Requirements
Platform has 2 levels of handrails (approx. 0.5m & 1.0m high)
-
Mean Velocity
Yes
Yes
Traverse 1
Yes
N/A
SUITABILITY OF SAMPLING LOCATION
Outside
Yes
Lowest Gas Velocity
m/s
Horizontal
Compliant
-
11.14
-
-
m/s -
There are no obstructions present which hamper insertion of sampling equipment
-
Permanent / Temporary Platform
Inside / Outside
41.0
Circular
Yes
Type
-
1.60
-
Value
-
Value
Units
Executive Summary
cm
-
Pa
0.00
4.00 -
Number of Ports - 2
1.19 0.00 0.00 0.00
CAT-RT (Version BY)
Page 8 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 44 of 77
Executive Summary
Photo 1 Photo 2
PLANT PHOTOS
(Page 7 of 7)
SAMPLE POINTS
where = isokinetic point sampled at
= isokinetic point not sampled at
= combustion gases sample point
= non-isokinetic sample pointLine A
A1
CAT-RT (Version BY)
Page 9 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 45 of 77
APPENDIX 1 - Stack Emissions Monitoring Personnel, List of Equipment & Methods and Technical Procedures Used
APPENDIX 2 - Summaries, Calculations, Raw Data and Charts
APPENDIX CONTENTS
APPENDICES
CAT-RT (Version BY)
Page 10 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 46 of 77
Oven Box (1)
ISO 12039
-
Laboratory Balance
Tape Measure -
EN 14792
Equipment I.D.
BS EN 13725
CAT-TP-09
CAT-TP-20
CAT-TP-05
CAT-TP-30
EN 12619:2013
EN 14789
Equipment I.D.
CAT 6.57
-
EN 14791
-
-
CAT 3.117
Oven Box (2)
CAT 4.830
TE1 & TE4
ABB AO2020-URAS26
Digital Manometer (1)Horiba PG-350E
CAT 20.102
Equipment Type
-
20m Heated Line (1)
Tubes Kit Thermocouple -
20m Heated Line (2)
-
CAT 12.84
-
Gasmet Sampling SystemCAT 5.116
Hioki 5043 (V)
Technical Endorsements
S-Pitot (1)
L-Pitot
Barometer
Digital Manometer (2)
Umbilical (1)
Box Thermocouples (2)
Box Thermocouples (1)
Mass Flow Controller (2) 15m Heated Line (1)
CAT 17.30
-
Technical ProcedureStandard
Heated Probe (1)
Bernath 3006 FID CAT 8.20
-
Ankersmid APS 313
CAT 13.34
Mass Flow Controller (1)
Digital Temperature Meter
Heated Probe (3) -
Stack Thermocouple (3)
Single Channel Heater Controller
-
-
CAT 25.56
- 1m Heated Line (2)Heated Probe (2)
CAT 25.55
Parameter
CAT 39.9
Eco Physics CLD 822Mh
TE1 TE2 TE3 TE4
Site Balance
M&C PSS
Instrumental Analysers
CAT 3.134
-
Mass View (2)
1m Heated Line (1)-
-
CAT 14.53
-
S-Pitot (2)
CAT 11.79
1m Heated Line (3)
Control Box DGM (1)
METHODS & TECHNICAL PROCEDURES USED
CAT 7.55
Equipment Type Equipment Type
Control Box DGM (2)
CAT 4.831
James Magann MCERTS Level 2
SELECT Logger 2 -
Dual Channel Heater Controller -500g / 1Kg Check Weights CAT 17.30
Last Impinger Arm -
Callipers
-
Umbilical (2) Testo 350 XL
MM17 1414
-
CAT 21P.92
Technician
Position
Team Leader
CAT 6.58
-
-
-
MCERTS Level 1
Name
SELECT FTIR
STACK EMISSIONS MONITORING PERSONNEL
Stack Thermocouple (1)
Extractive Sampling
LIST OF EQUIPMENT
MCERTS Accreditation
CAT 4.754
MCERTS Number
Miscellaneous Items
EN 15058Carbon Monoxide
EN 16911-1 (MID) CAT-TP-41
Carbon Dioxide
Odour
Water Vapour
CAT-TP-39
CAT-TP-39
CAT-TP-39
EN 14790
Velocity & Vol. Flow Rate
CAT-TP-39
-
Brian Walsh
Equipment I.D.
APPENDIX 1
Mass View (1)
-
Sulphur Dioxide
MM15 1330
SELECT Horiba Model (2)
-
Total VOCs (as Carbon)
Oxides of Nitrogen (as NO₂)
Oxygen
-
5m Heated Line (1) -
SELECT Servomex Model -
Stack Thermocouple (2)
Stopwatch
Bioaerosols Temperature Logger -
Electronic Refrigerator -
CAT-RT (Version BY)
Page 11 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 47 of 77
General Stack Details
Stack Gas Composition & Molecular Weights
CO₂
O₂
Moisture (H₂O)
Where: p = M / 22.41
pi = r x p
Calculation of Stack Gas Densities
Where: P STD = sum of component concentrations, kg/m³ (not including water vapour)
P STW = sum of all wet concentrations / 100 x density, kg/m³ (including water vapour)
P Actual = P STD x (TSTP / (PSTP)) x ((Pstatic + Pb) / Ta)
P ActualW (at each sampling point) = P STW x (Ts / Ps) x (Pa / Ta)
Calculation of Stack Gas Volumetric Flowrate, Q
-
Volume
kPa
kPa
0.84
-
17.0
0.00
kg/m³
Dry Density (STP), P STD
0.0845
18.02
Determinand
Average Pitot Tube Calibration Coefficient, Cp
ppm
% v/v Mr% v/v
kg/m³
m³/hr
Total Pressure
Average Wet Density (Actual), P ActualW
2.11
84.84
°C
Gas Volumetric Flowrate (STP, Dry)
1.06042
1.322
83.05
265.5
100.0
Gas Volumetric Flowrate REF ¹
-0.0
%
m³/hr
Units
Units
Gas Volumetric Flowrate (STP, Wet)
Moisture
kPa
0.01700
2.11
-
Result
Dry Density (Actual), P Actual
Units
1.311
Duct gas flow conditions
36836
73596
0.662
Wet Density (STP), P STW
36057
8.45
kg/m³
kg/m³
0.8484 28.01
101.3
1.9635
1.2498
44.01
6.71 32.00 1.4277 0.09580-
0.16583
0.0211
Conc
Mass
Component
PRELIMINARY STACK SURVEY: CALCULATIONS
%
0.8037
Temperature
N₂
kg/m³
265.5
Average Barometric Pressure, Pb
m
Actual
6.7
p pi
Result
8.27
Average Stack Static Pressure, Pstatic
48.5
Wet
m³/hr
°C
Conc
Gas Volumetric Flowrate (Actual)
2.01
-
0.0671
m³/hr
REF ¹
Oxygen (Dry)
0.328
-
mStack Width, W
Stack Details (from Traverse)
Fraction
Density
Dry
Stack Area, A
128814
kg/m³
Molar Conc
Value
1.60
100.2
Average Stack Gas Temperature, Ta
-0.187
Stack Diameter / Depth, D
Average Stack Gas Pressure
Conc
6.57
APPENDIX 2
-
Units
Pa
Gas Volumetric Flowrate (from Traverse)
m²
CAT-RT (Version BY)
Page 12 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 48 of 77
Parameter Parameter
Date of Survey Initial Pitot Leak Check
Time of Survey Final Pitot Leak Check
Atmospheric Pressure Orientation of Duct
Average Stack Static Pressure Pitot Tube, Cp
Result of Pitot Stagnation Test Number of Lines Available
Are Water Droplets Present? Number of Lines Used
Device Used
Velocity
10.29
2-
2.0
0.656
58.0
2
0.657
1.49 44.0
265.0
42.0
-
0.656
3.0
4
48.0
266.0
1.058.0
1.203 9.49
1
41.0 266.0
266.0
0.40
3.0 9.71
9.49
0.656
0.657
0.656
266.0 0.656
0.656
11.14
4.0
42.0
49.8 265.5
1.0
9.38
47.3
10.85
Pa
Point kg/m³ °
0.11
Pass
PRELIMINARY STACK SURVEY: VELOCITY TRAVERSE TO EN 16911-1 (MID)
Pa
Pass
∆P
-
(1 of 1)
2
APPENDIX 2
2.0
265.5
10.13
11.14
Value
∆P Temp
Sampling Line B
Units
Wet Density
m
-
Temp Swirl
No
STATIC (Units: Pa)
265.0
10:12 - 10:22
Sampling Line A
kPa
-
Wet Density
-
-
-187 -
10.05
0.657
kg/m³
2.0
°C°
55.0
m/s°C
-186.0
m/sPa
-
265.0
265.0
Mean
-187.0
-
0.84
Swirl
Horizontal
Pass
Traverse
100.2
VelocityDepth
S-Type Pitot with KIMO MP 210 (500Pa)
06/09/2018
ValueUnits
0.657
CAT-RT (Version BY)
Page 13 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 49 of 77
Standard uncertainty associated with the mean velocity (95% Confidence)
- Resolution
- Calibration
-
Uc(qV,w)
m/s
- Overall corrections to dynamic measurements
Standard uncertainty associated with the molar mass of the gas
- φO₂,w
0.00053
- u(qV,w)
Standard uncertainty associated with the volume flow rate (95% Confidence), relative
Standard uncertainty associated with the absolute pressure in the duct
- Atmospheric Pressure
u(drift) 0.083
0.00354
Performance characteristics (Uncertainty Components) Uncertainty
%
Standard uncertainty associated with the volume flow rate (95% Confidence)
Pa
u(res) 0.00087
u(M) 0.00004
0.146
u(v) 0.065
Uc(v)
- Drift
- Lack of Fit
0.930
u(ρ)
Standard Uncertainty on the coefficient of the Pitot Tube
0.730
u(k) 0.005
Value Units
-
0.401u(fit)
Uc,rel(v) 1.26
0.128
- Water Vapour
- Oxygen, wet
- Carbon Dioxide, wet
-
u(∆pi)Standard Uncertainty associated with the mean local dynamic pressures
- φCO₂,w
- Oxygen, dry
- Carbon Dioxide, dry
- Static Pressure
Standard uncertainty associated with the density in the duct
u(vi)
K
u(pc) 175.695 Pa
u(patm) 175.692
u(pstat)
Standard uncertainty associated with the mean velocity (95% Confidence), relative
Standard uncertainty associated with the mean velocity
0.00057
- 3110820
- 1763.8
Uc,rel(qV,w) 4.70
-
Pa
m/s
%
u(φH₂O) 0.108
u(φO₂,w) 0.201
u(φCO₂,d) 0.259
Standard uncertainty associated with the stack temperature
-
APPENDIX 2
Standard uncertainty associated with the local velocities
u(Cf)
u(cal) 0.245
PRELIMINARY STACK SURVEY: VELOCITY TRAVERSE TO EN 16911-1 (MID) - MEASUREMENT UNCERTAINTY(1 of 1)
3457.0 m³/hr
- u²(qV,w)
1.315
2.747u(Tc)
-
6.568
- 8.267
u(φO₂,d) 0.205
u(φCO₂,w) 0.253
- u²(a)/a²
- u²(qV,w)/q²V,w
CAT-RT (Version BY)
Page 14 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 50 of 77
Sample Runs
- -
- -
- -
- -
- -
- -
- -
- -
Blank Runs
- -
- -
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, dry gas, 17% oxygen.
0.14
CAT-AP-01
ISO 17025 Accredited Analysis?
Date of Sample Analysis
CAT
Mean
Concentration mg/m³ 0.14
0.001
Mass Emission
Uncertainty
2.11
APPENDIX 2
15/09/2018
Units Blank 1
0.110.11
Yes
Analytical Laboratory's Procedure
SULPHUR DIOXIDE: RESULTS SUMMARY
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
18.5g/hr
1.8
EN 14791
A1
Number of Sampling Lines Used
Standard
Filter Size and Material
1.8
Parameter Units
Value
0.001
Parameter
Uncertainty
Parameter
Titanium
Impinger Material Borosilicate Glass
Technical Procedure CAT-TP-09
Probe Material Titanium
Filter Housing Material
Sample Point I.D.'s
Thermal Oxidiser
Parameter Units
Number of Sampling Points Used 1 / 1
±% v/v
Run 1
Mean
Uncertainty
Water Vapour % v/v 2.11
Positioning of Filter
mg/m³
Name of Analytical Laboratory
0.01
1 / 1
Run 1
Absorption Solution 0.05 mol/l Sulphuric Acid
±mg/m³ 0.01
Concentration
18.5
Maximum
±g/hr
47mm Quartz Fibre
In Stack
CAT-RT (Version BY)
Page 15 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 51 of 77
Sample Runs
-
-
-
-
-
-
-
-
Where: DGM stands for Dry Gas Meter
Blank Runs
-
-
-
-
Sampling Device
Sampling Times
23.0
12.30
Sample Flow Rate
18.8974
Duration mins
Blank Dates
Volume Sampled (REF) m³
Calculated Water Vapour % v/v 2.11
Silica Trap Start Mass g 878.0
-
30
Mass in Back Impinger
Total Mass Collected
DGM End Temperature °C
Volume Sampled (STP, Dry) m³
µg
Units
23.0
Liquid Trap End Mass g 1257.0
5.3867
206.0
µg 2715.1
Barometric Pressure kPa 101.8
Laboratory Result for Back Impinger
g
5.5031
1168.6
Calculated Concentration mg/m³ 0.001
Average Volume Sampled (REF) m³ 18.8974
µg 16.0
SULPHUR DIOXIDE: SAMPLING DETAILS
Silica Trap End Mass g 883.0
Run 1
Start ∆H
- 06/09/2018
g
- DGM
APPENDIX 2
Sampling Dates - 06/09/2018
12:45 - 13:15
Parameter
Mass in Front Impingers
m³ 7.3020DGM Start Volume
Volume Sampled (STP, Wet) m³
Laboratory Result for Front Impingers µg/ml 13.18
Laboratory Result for Impingers µg/ml
Total Mass Of Water Vapour
0.9490
Calculated Concentration mg/m³ 0.14
l/min 193.56
Blank 1
Volume in Front Impingers ml
End ∆H mmH₂O
Parameter Units
mmH₂O
93.4
Total Mass Collected
12.80
0.05
Liquid Trap Start Mass
µg 5.2
2720.3
Volume in Back Impinger ml 104.0
DGM Yd -
DGM Start Temperature °C
µg/ml 0.05
DGM End Volume m³ 13.4210
Volume in Impingers ml 320.0
CAT-RT (Version BY)
Page 16 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 52 of 77
Sample Runs
1 0 0 1
Blank Runs
Method Deviations
1
wx
- - - - -
- - - - -
- - - - -
Allowable Leak Rate l/min 3.87
Measurement Uncertainty (MU) % 5.2
Mean Sampling Rate l/min
Pre-Sampling Leak Rate
Silica Gel (Concurrent Water Vapour) Units Run 1
Absorption Efficiency Units
%
APPENDIX 2
Post-Sampling Leak Rate
193.6
Are Water Droplets Present - No
Less than 50% Faded
Run 1
95
Units Blank 1
SULPHUR DIOXIDE: QUALITY ASSURANCE
Leak Test Results Units Run 1
Absorption Efficiency
Leak Test Results
Leak Test Acceptable - Yes
MU (Concurrent Water Vapour) Units Run 1
l/min 0.02
99.8
Pre-Sampling Leak Rate l/min 0.02
Blank Acceptable
-
Validity of Blank vs ELV Units Blank 1
% Yes
Expected Sampling Rate l/min 10.0
0.20
% 20.0Allowable MU
Post-Sampling Leak Rate l/min 0.02
Test Conditions
Nature of Deviation Run Number
- N/A
Yes
Leak Test Acceptable - Yes
Allowable Absorption Efficiency %
Absorption Efficiency Acceptable -
Water Droplets Units Run 1
(x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run)
There are no deviations associated with the sampling employed.
Units Run 1
mg/m³
l/min
MU Acceptable %
Allowable Leak Rate l/min
Ambient Temperature Recorded?
0.02
Yes
N/AAllowable Blank
Yes
CAT-RT (Version BY)
Page 17 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 53 of 77
Sampled Volume (Actual)
Sampled Gas Temperature
Sampled Gas Pressure
Sampled Gas Humidity
Leak
Laboratory Result
Sampled Volume (Actual)
Sampled Gas Temperature
Sampled Gas Pressure
Sampled Gas Humidity
Leak
Laboratory Result
Sampled Volume (STP)
Leak
Laboratory Result
Sampled Volume (STP)
Leak
Laboratory Result
O₂ Correction Factor
Stack Gas O₂ Content
MU for O₂ Correction
Combined uncertainty
Expanded uncertainty (95% confidence), without Oxygen Correction
Expanded uncertainty (95% confidence), with Oxygen Correction
Expanded uncertainty (95% confidence), estimated with Method Deviations
Reported Uncertainty
Expanded uncertainty (95% confidence), without Oxygen Correction
Expanded uncertainty (95% confidence), with Oxygen Correction
Expanded uncertainty (95% confidence), estimated with Method Deviations
Reported Uncertainty
≤1%
Requirement of Standard
%
0.49
%
2.0
Measured Quantities
uL
%
Vm
APPENDIX 2
SULPHUR DIOXIDE: MEASUREMENT UNCERTAINTY CALCULATIONS
Value Standard uncertainty
ρm 101.8
296.0
m³
%
Units
0.01
0.01
mg/m³ 0.004
0.01
Overall MU For O₂ Measurement
Uncertainty in Measurement Units Sensitivity Coefficient
6.1190
≤1%
%
Run 1Measured Quantities Units
%
uHm % v/v
8.4
mg/m³
Symbol Units Run 1
Symbol
K
L 0.01
Tm
0.01
7.7
mg/m³
%
mg/m³
3.56
mg/m³ 0.01
Units Run 1
mg/m³
% 8.4
0.0042
8.4
-
Run 1
0.68
Measured Quantities Units Run 1
0.0000
2.90
1.00
≤2%
mg/m³ 0.01
Oxygen Correction Part of MU Budget
% v/v
No Requirement
mg/m³
uVm
1.00
- 0.29
Run 1
0.01
0.004
1.00
%
Uncertainty as a Percentage
Units
L mg/m³ 0.000
Hm 0.0
%
Lr
1.0
Lr 2.90
0.03
uLr
≤1%
2.00
0.1224
Uncertainty in Result
Parameter
Symbol Run 1
uρm kPa 0.5
-
≤2%
%
6.97
-
Measured Quantities
mg/m³
uTm
Run 1Measured Quantities
%
%
Vm m³ 5.3867
CAT-RT (Version BY)
Page 18 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 54 of 77
Sample Runs
- -
- -
- -
- -
- -
General Sampling Information
This is the blended concentration of both propane cylinders
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, dry gas, 17% oxygen.
±g/hr
Zero Gas Type
15.3
83.29 | 79.9
Number of Sampling Points Used
Parameter
Span Gas Start Pressure (bar) 100 | 100
Gas Cylinder Concentration (ppm)
0.09
CAT-TP-20
Mean
APPENDIX 2
Mass Emission
Concentration
g/hr
Span Gas Reference Number
Parameter Units
Span Gas Set Point (ppm) 81.68
1 / 1
15.3
Span Gas Expiry Date
0.09
Thermal Oxidiser
TOTAL VOCs (as CARBON): RESULTS SUMMARY
Number of Sampling Lines Used
Standard
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
EN 12619:2013
Technical Procedure
Run 1
11/10/2022 | 11/10/2022
Uncertainty
1 / 1
Uncertainty 0.12
12.1
±mg/m³
10% O₂ in N₂ (5 Grade)
180°C
Probe Material Stainless Steel
Filtration Type / Size 0.1µm Glass Fibre
Sample Point I.D.'s A1
Value
1.0212N in N₂ | 1.0300A in AIR
2 | 2
Yes
Heated Line Temperature
mg/m³
0.12
Span Gas Uncertainty (%)
12.1
Heated Head Filter Used
Span Gas Type Propane in 10% O₂ in N₂ (5 Grade)
CAT-RT (Version BY)
Page 19 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 55 of 77
Graphical Trend of Data
APPENDIX 2
COVER ME WITH CHART/S
TOTAL VOCs (as CARBON): DATA TREND
0.0
0.1
0.1
0.2
0.2
0.31
2:2
5
12
:27
12
:29
12
:31
12
:33
12
:35
12
:37
12
:39
12
:41
12
:43
12
:45
12
:47
12
:49
12
:51
12
:53
12
:55
12
:57
12
:59
13
:01
13
:03
13
:05
13
:07
13
:09
13
:11
13
:13
13
:15
13
:17
13
:19
13
:21
13
:23
13
:25
Co
nce
ntr
atio
n (
mg/
m³)
Total VOCs At Reference Conditions
- Run 1
CAT-RT (Version BY)
Page 20 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 56 of 77
Sampling Details
Quality Assurance
Zero Drift 0 0 0
Zero Drift
Drift Correction Applied
Span Drift 0 0 0
Span Drift
Drift Correction Applied
Method Deviations
1
x
- - -
- - -
- - -
- - -
- - -
ppm 82.00
Parameter
Span Gas Value 81.7
Sampling Dates
°C
Run Number
Test Conditions
There are no deviations associated with the sampling employed.
ppm -0.80
Span Down Sampling Line (Pre)
Units
Nature of Deviation
(x = deviation applies to the associated run)
Yes-
Units
- Yes
Allowable Zero Drift
Run Ambient Temperature Range 21 - 22
4.08
Span Drift Acceptable
Allowable Span Drift ± ppm
Run 1
06/09/2018
-
ppm
82.80
CA
L 1
0.00Zero Down Sampling Line (Post) ppm
± ppm
Span Down Sampling Line (Post)
4.08
0.00ppm
100
0.00
ppm
Run 1
TOTAL VOCs (as CARBON): SAMPLING DETAILS & QUALITY ASSURANCE
Run 1Span Drift
Units Run 1
Units
ppm
Sampling Times
CA
L 1
Zero Drift
12:25 - 13:25
Instrument Range
ppm
Zero Drift Acceptable
APPENDIX 2
-
Zero Down Sampling Line (Pre)
%
2-5%
%
2-5%
0.00
No
-0.97
No
CAT-RT (Version BY)
Page 21 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 57 of 77
k =
APPENDIX 2
1.40
Volume or pressure flow dependence
mg/m³ (REF)
% of value
Zero drift 0.00
Volume or pressure flow dependence
% full scale
0.00
mg/m³
% at ELV
Ambient temperature dependence
Expanded uncertainty (no O₂) - at 95% Confidence 125.97 % of Value
RUN 1 Units
0.12
% at ELV
Overall Allowable uncertainty (no O₂) - at 95% Confidence N/A
0.04
% of Value
RUN 1
Expanded uncertainty (no O₂) - at 95% Confidence N/A
Result of Compliance with Uncertainty Requirement in M2
N/A
mg/m³
Combined interference (from MCERTS Certificate)
Expanded uncertainty 1.96 0.43 mg/m³
Uncertainty corrected to std conds. (O₂)
Measured concentration
-
Requirement for SRM is that Uncertainty should be <15% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 15% + the
uncertainty associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2.
-
126.00
mg/m³
Repeatability at span level 0.00
-
ppm
0.00
TOTAL VOCs (as CARBON): MEASUREMENT UNCERTAINTY CALCULATIONS
Limit value
% full scale
Conversion 1.61
mg/m³
TGN M2 Allowable MU
Performance characteristics RUN 1 Units
Combined interference
Ambient temperature dependence
% of value
131.2
% of value/kPa
Number of readings in measurement
Atmospheric pressure dependence 0.30
% full scale/10K
160.6
Range Used 100.0
60
% full scale
Repeatability at zero
Standard deviation of repeatability at span level
% full scale
Uncertainty of calibration gas 2.83 % of value
Units
Standard deviation of repeatability at zero
Deviation from linearity 0.08
mg/m³
1.60
mg/m³
%
0.34 mg/m³ (STP, dry)
Span drift -0.97
% of full scale
Range Used [A]
RUN 1
0.22
mg/m³ (REF)
15.0
-
RUN 1 Units
Response time 45
mg/m³
ppm to mg/m³
MCERTS Range [B] 15.0
% range
mg/m³
Lack of fit 0.01
0.45
mg/m³
Cal gas conc. 81.7 ppm
Performance characteristic
mg/m³
mg/m³
Cal gas conc.
mg/m³
0.06
mg/m³
0.50 % full scale/10V
Losses in the line (leak) 0.00
Performance characteristics
mg/m³
Lower of [A] or [B]
seconds
Measurement uncertainty
Expanded uncertainty (with O₂) - at 95% Confidence
mg/m³
Combined uncertainty
Units
N/A
Units
Dependence on voltage
Result 0.34
0.01
% at ELV
% at ELV
Losses in the line (leak) 0.00
0.20
2.00
15.0 mg/m³
mg/m³
Uncertainty of calibration gas
RUN 1
Drift 0.00
Dependence on voltage
use rep at span
Atmospheric pressure dependence 0.01
Expanded uncertainty (with O₂) - at 95% Confidence N/A
Overall Allowable uncertainty (with O₂) - at 95% Confidence
Result of Compliance with Uncertainty Requirement in M2 N/A
CAT-RT (Version BY)
Page 22 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 58 of 77
Sample Runs
- -
- -
- -
- -
- -
General Sampling Information
NOTE: Dilution performed to achieve correct span value
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, dry gas, 17% oxygen.
Span Gas Reference Number 12.0174
Span Gas Expiry Date
8.17
Span Gas Uncertainty (%)
1 / 1
Number of Sampling Points Used
Filtration Type / Size
CAT-TP-39
8.17
180
Parameter
Stainless Steel
Number of Sampling Lines Used
APPENDIX 2
OXIDES OF NITROGEN (as NO₂): RESULTS SUMMARY
Run 1
2
A1
Standard
Sample Point I.D.'s
Technical Procedure
Heated Line Temperature
1 / 1
28/07/2020
18/04/2018 - 95.1%
Zero Gas Type Nitrogen (5 Grade)
1642.0
Heated Head Filter Used
Span Gas Type Nitrogen Monoxide
Date & Result of Last Converter Check
0.1µm Glass Fibre
EN 14792
Uncertainty ±mg/m³
208.29
Span Gas Start Pressure (bar) 120
Gas Cylinder Concentration (ppm)
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Thermal Oxidiser
Parameter Units Mean
208.29
Value
Mass Emission 26830.6g/hr
Uncertainty
Probe Material
417.2
Yes
1642.0±g/hr
26830.6
Concentration mg/m³
CAT-RT (Version BY)
Page 23 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 59 of 77
Graphical Trend of Data
COVER ME WITH CHART/S
APPENDIX 2
OXIDES OF NITROGEN (as NO₂): DATA TREND
0.0
50.0
100.0
150.0
200.0
250.0
300.0
12
:25
12
:27
12
:29
12
:31
12
:33
12
:35
12
:37
12
:39
12
:41
12
:43
12
:45
12
:47
12
:49
12
:51
12
:53
12
:55
12
:57
12
:59
13
:01
13
:03
13
:05
13
:07
13
:09
13
:11
13
:13
13
:15
13
:17
13
:19
13
:21
13
:23
13
:25
Co
nce
ntr
atio
n (
mg/
m³)
Oxides of Nitrogen (as NO₂) At Reference Conditions
- Run 1
CAT-RT (Version BY)
Page 24 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 60 of 77
Sampling Details
Quality Assurance
Average Temperature
Zero Drift 0 0 0
Zero Drift
Drift Correction Applied
Span Drift 0 0 0
Span Drift
Drift Correction Applied
Method Deviations
1
x
- - -
- - -
- - -
Allowable Zero Drift
Zero Drift Acceptable
< °C
Span at Analyser (Post) ppm
Zero at Analyser (Post) ppm 0.00
-
ppm 300.00
-
Units
Run Number
Yes
ppm
Run 1
300.10
ppm
Units Run 1
0.10
Run 1
(x = deviation applies to the associated run)
4.0
Instrument Range
Run Ambient Temperature Range
15.00
There are no deviations associated with the sampling employed.
Run 1
± ppm 15.00
ppm 0.00
Nature of Deviation
Zero Drift
21 - 22
Span Drift
06/09/2018
CA
L 1
300.0
Allowable Temperature
0.00
Sampling Dates
Temperature Acceptable - Yes
Units
Zero at Analyser (Pre)
Conditioning Unit Temperature
ppm
Span Gas Value ppm
Run 1
Sampling Times
1000
Units
12:25 - 13:25
APPENDIX 2
OXIDES OF NITROGEN (as NO₂): SAMPLING DETAILS & QUALITY ASSURANCE
Parameter
°C 2.4
-
Allowable Span Drift
Test Conditions
Units
CA
L 1
± ppm
°C
Span at Analyser (Pre)
Span Drift Acceptable - Yes
% 0.00
2-5% No
% 0.03
2-5% No
CAT-RT (Version BY)
Page 25 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 61 of 77
k =
Zero drift
Units
mg/m³
OXIDES OF NITROGEN (as NO₂): MEASUREMENT UNCERTAINTY CALCULATIONS
mg/m³
-0.23
TGN M2 Allowable MU
Performance characteristic RUN 1
0.06
Ratio NO / NO₂
Measured concentration
use rep at span
-
% full scale/10K
Atmospheric pressure dependence
%
750.81
615.7
205.0
Range Used [A]
Result of Compliance with Uncertainty Requirement in M2
seconds
% of full scale
mg/m³
mg/m³
mg/m³
mg/m³
750.81
ppm to mg/m³
mg/m³
mg/m³ (REF)
10.0
% full scale
Volume or pressure flow dependence 0.10
Cal gas conc.
1.40
0.14
Atmospheric pressure dependence
Combined interference
%
Expanded uncertainty (with O₂) - at 95% Confidence
mg/m³
Drift
0.63
% of value
mg/m³
APPENDIX 2
Range Used ppm
mg/m³
Lower of [A] or [B]
Cal gas conc. 300.0
2052.3 mg/m³
ppm
Conversion 2.05
Performance characteristics RUN 1
1000.0
Converter efficiency
MCERTS Range [B] 205.0
0.04
0.10
Units
Response time 31
0.00
Limit value
mg/m³ (STP, dry)
5
% full scale
Dependence on voltage
Number of readings in measurement 30 -
% of value
Repeatability at span level 0.10
% at ELV
Overall Allowable uncertainty (with O₂) - at 95% Confidence N/A % at ELV
0.02
Requirement for SRM is that Uncertainty should be <10% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 10% + the
uncertainty associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2.
% of value
% of value
Repeatability at zero 0.00 % full scale
Expanded uncertainty (no O₂) - at 95% Confidence
mg/m³
Uncertainty corrected to std conds. (O₂) 5.88
Dependence on voltage
% full scale/10V
95.1 %
0.75
Standard deviation of repeatability at span level
Units
Expanded uncertainty (with O₂) - at 95% Confidence 3.92
Uncertainty of calibration gas blending
% at ELV
Overall Allowable uncertainty (no O₂) - at 95% Confidence N/A
Losses in the line (leak)
% at ELV
Result of Compliance with Uncertainty Requirement in M2 N/A -
RUN 1
0.00
2.00
1.59
Combined interference (from MCERTS Certificate)
-0.03
mg/m³
mg/m³
RUN 1
-
mg/m³
Expanded uncertainty (no O₂) - at 95% Confidence N/A
RUN 1
Expanded uncertainty
10.81
N/A
21.18
Uncertainty of calibration gas
mg/m³ (REF)
mg/m³
8.67
2.82
% of Value
1.96
Uncertainty of calibration gas blending 6.07
% range
Volume or pressure flow dependence 0.00
Uncertainty of calibration gas
Lack of fit
Units
Standard deviation of repeatability at zero
mg/m³
Combined uncertainty
Ambient temperature dependence 0.01
mg/m³
Units
Measurement uncertainty Result
mg/m³
Losses in the line (leak) 0.00
Converter efficiency
mg/m³
1.06
Performance characteristics RUN 1
% full scale
Deviation from linearity 1.34
Span drift 0.03
Units
% of Value
% of value/kPa
Ambient temperature dependence
N/A
CAT-RT (Version BY)
Page 26 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 62 of 77
Sample Runs
- -
- -
- -
- -
- -
General Sampling Information
NOTE: Dilution performed to achieve correct span value
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 273K, 101.3kPa, dry gas, 17% oxygen.
Uncertainty
Concentration
Value
mg/m³ 1.08
120
g/hr
APPENDIX 2
Thermal Oxidiser
Mean
CARBON MONOXIDE: RESULTS SUMMARY
Parameter Units
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Run 1
Zero Gas Type
408.3Gas Cylinder Concentration (ppm)
0.1µm Glass Fibre
±mg/m³
1.08
Span Gas Expiry Date 28/07/2020
2
Number of Sampling Lines Used 1 / 1
Span Gas Start Pressure (bar)
1 / 1
Nitrogen (5 Grade)
±g/hr
Span Gas Uncertainty (%)
139.5
Yes
Heated Line Temperature
Technical Procedure CAT-TP-39
Sample Point I.D.'s
Span Gas Reference Number
A1
Number of Sampling Points Used
12.0174
0.29
Filtration Type / Size
38.3
Parameter
Standard
Uncertainty
Mass Emission
0.29
Probe Material Stainless Steel
180
38.3
Heated Head Filter Used
139.5
Span Gas Type Carbon Monoxide
EN 15058
CAT-RT (Version BY)
Page 27 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 63 of 77
Graphical Trend of Data
APPENDIX 2
CARBON MONOXIDE: DATA TREND
COVER ME WITH CHART/S
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.51
2:2
5
12
:27
12
:29
12
:31
12
:33
12
:35
12
:37
12
:39
12
:41
12
:43
12
:45
12
:47
12
:49
12
:51
12
:53
12
:55
12
:57
12
:59
13
:01
13
:03
13
:05
13
:07
13
:09
13
:11
13
:13
13
:15
13
:17
13
:19
13
:21
13
:23
13
:25
Co
nce
ntr
atio
n (
mg/
m³)
Carbon Monoxide At Reference Conditions
- Run 1
CAT-RT (Version BY)
Page 28 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 64 of 77
Sampling Details
Quality Assurance
Average Temperature
Zero Drift 0 0 0
Zero Drift
Drift Correction Applied
Span Drift 0 0 0
Span Drift
Drift Correction Applied
Method Deviations
1
x
- - -
- - -
- - -
160.00
°C
CARBON MONOXIDE: SAMPLING DETAILS & QUALITY ASSURANCE
Parameter
4.0
Yes
Test Conditions
8.00
-
Span Drift
ppm
Zero at Analyser (Pre)
CA
L 1
Allowable Temperature < °C
Span at Analyser (Post)
0.01
Sampling Times
°C 21 - 22
APPENDIX 2
Run 1
Temperature Acceptable
ppm
ppm
158.00
Zero Drift Acceptable -
12:25 - 13:25
Units
Instrument Range 200
Nature of Deviation
ppm
Run 1
Run Number
Span at Analyser (Pre) ppm
ppm
Zero Drift
Units
- 06/09/2018
YesSpan Drift Acceptable
Run 1
Sampling Dates
-
Run 1
Span Gas Value
Run 1
Yes
8.00
Zero at Analyser (Post)
Conditioning Unit Temperature
Units
ppm
ppm 0.00
Units
CA
L 1
0.01
-2.00
± ppm
-
2.4
160.0
Units
Allowable Span Drift ± ppm
(x = deviation applies to the associated run)
There are no deviations associated with the sampling employed.
Run Ambient Temperature Range
Allowable Zero Drift
2-5% No
% -1.25
2-5% No
% 0.01
CAT-RT (Version BY)
Page 29 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 65 of 77
k =
-1.25
-
mg/m³
Cal gas conc. 160.0
Limit value
200.0
75.0
Ambient temperature dependence mg/m³
Standard deviation of repeatability at zero
0.04
% full scale
Standard deviation of repeatability at span level
Units
Expanded uncertainty (with O₂) - at 95% Confidence
mg/m³
mg/m³
Lack of fit 0.44
% of value
Performance characteristic RUN 1
Units
Response time 28
mg/m³
Combined uncertainty
Uncertainty of calibration gas 2.00
1.40 % of value
Volume or pressure flow dependence
% full scale/10K
mg/m³
Uncertainty of calibration gas blending 0.03 mg/m³
Losses in the line (leak)
Measurement uncertainty
% range
Dependence on voltage -0.35 % full scale/10V
Volume or pressure flow dependence 0.00
Performance characteristics RUN 1
% full scale
seconds
mg/m³ (REF)
6.0 %
3.90
Units
ppm to mg/m³
RUN 1
Number of readings in measurement
mg/m³
249.8
0.05 mg/m³
Combined interference (from MCERTS Certificate) -0.21
mg/m³
Drift
Dependence on voltage -0.04
% at ELV
3.90
mg/m³
Losses in the line (leak) 0.02
% at ELV
Result of Compliance with Uncertainty Requirement in M2
RUN 1
RUN 1 Units
Expanded uncertainty (no O₂) - at 95% Confidence 26.93
Overall Allowable uncertainty (with O₂) - at 95% Confidence N/A
% full scale
Deviation from linearity 1.01
% full scale
Performance characteristics
-0.03
MCERTS Range [B]
Cal gas conc. 199.9
Zero drift 0.01
use rep at span mg/m³
Atmospheric pressure dependence
0.20
-
mg/m³ (STP, dry)
Lower of [A] or [B] 75.0
% at ELV
Result of Compliance with Uncertainty Requirement in M2 N/A -
Requirement for SRM is that Uncertainty should be <6% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 6% + the uncertainty
associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2.
TGN M2 Allowable MU
Conversion 1.25
% of full scale
Atmospheric pressure dependence 0.22 % of value/kPa
Expanded uncertainty (with O₂) - at 95% Confidence N/A % at ELV
Overall Allowable uncertainty (no O₂) - at 95% Confidence N/A
27.06 % of Value
0.10
Ambient temperature dependence -0.20
mg/m³
% of Value
Expanded uncertainty (no O₂) - at 95% Confidence N/A
ppm
Range Used [A]
0.10
30
Repeatability at zero
mg/m³
Repeatability at span level
% of value
Units
Combined interference -0.48
mg/m³
ppm
APPENDIX 2
CARBON MONOXIDE: MEASUREMENT UNCERTAINTY CALCULATIONS
Range Used
Measured concentration
Span drift
-0.02 mg/m³
Uncertainty of calibration gas 0.05
0.69 % of value
Uncertainty of calibration gas blending
mg/m³
Expanded uncertainty 1.96 1.05 mg/m³
Uncertainty corrected to std conds. (O₂) 0.29 mg/m³ (REF)
Units
N/A -
mg/m³
RUN 1
Result
0.54
CAT-RT (Version BY)
Page 30 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 66 of 77
Sample Runs
- -
- -
- -
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Span Gas Expiry Date
180
Filtration Type / Size
Span Gas Uncertainty (%) 2.00
Probe Material
0.26
Technical Procedure
Span Gas Type Carbon Dioxide
Parameter
Thermal Oxidiser
Stainless Steel
Uncertainty
Concentration % v/v 8.45
Gas Cylinder Concentration (% v/v)
Sample Point I.D.'s A1
Value
16.00
Run 1
Yes
Units
0.1µm Glass Fibre
Heated Head Filter Used
Heated Line Temperature
CAT-TP-39
APPENDIX 2
CARBON DIOXIDE: RESULTS SUMMARY
Mean
0.26
Zero Gas Type Nitrogen (5 Grade)
1 / 1
Number of Sampling Points Used
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
6.0044Span Gas Reference Number
09/05/2023
Span Gas Start Pressure (bar) 100
Number of Sampling Lines Used
Parameter
Standard ISO 12039
1 / 1
8.45
±% v/v
CAT-RT (Version BY)
Page 31 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 67 of 77
Graphical Trend of Data
APPENDIX 2
CARBON DIOXIDE: DATA TREND
COVER ME WITH CHART/S
0.0
2.0
4.0
6.0
8.0
10.0
12.01
2:2
5
12
:27
12
:29
12
:31
12
:33
12
:35
12
:37
12
:39
12
:41
12
:43
12
:45
12
:47
12
:49
12
:51
12
:53
12
:55
12
:57
12
:59
13
:01
13
:03
13
:05
13
:07
13
:09
13
:11
13
:13
13
:15
13
:17
13
:19
13
:21
13
:23
13
:25
Co
nce
ntr
atio
n (
% v
/v)
Carbon DioxideCarbon Dioxide
- Run 1
CAT-RT (Version BY)
Page 32 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 68 of 77
Sampling Details
Quality Assurance
Average Temperature
Zero Drift 0 0 0
Zero Drift
Drift Correction Applied
Span Drift 0 0 0
Span Drift
Drift Correction Applied
Method Deviations
1
x
- - -
- - -
- - -
CA
L 1
% v/v
Span Down Sampling Line (Post) 16.00
Zero Down Sampling Line (Post) % v/v 0.01
% v/v 0.00
Units
21 - 22
2.4
Temperature Acceptable
Conditioning Unit Temperature
Sampling Dates
Zero Drift
- 12:25 - 13:25
% v/v
Parameter Units Run 1
Zero Down Sampling Line (Pre)
Allowable Temperature < °C
Yes
16.00
0.00
Run 1Units
Run 1
± % v/vAllowable Zero Drift
Zero Drift Acceptable
(x = deviation applies to the associated run)
4.0
CA
L 1
Nature of Deviation Run Number
°C
Allowable Span Drift
There are no deviations associated with the sampling employed.
Run Ambient Temperature Range
Test Conditions
Instrument Range % v/v
Span Gas Value % v/v 16.0
°C
30
CARBON DIOXIDE: SAMPLING DETAILS & QUALITY ASSURANCE
Units
0.01
± % v/v
0.80
% v/v
Span Down Sampling Line (Pre) % v/v
Span Drift
-
Run 1
- Yes
-
Run 1
Sampling Times
0.80
Span Drift Acceptable - Yes
APPENDIX 2
Units
06/09/2018
% 0.00
2-5% No
% 0.00
2-5% No
CAT-RT (Version BY)
Page 33 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 69 of 77
k =
Performance characteristics
Ambient temperature dependence
Atmospheric pressure dependence 0.03 %vol
APPENDIX 2
Response time
%vol
Units
Standard deviation of repeatability at zero use rep at span
Deviation from linearity 0.37
%vol
Zero drift 0.00
Number of readings in measurement 30
Atmospheric pressure dependence
Units
CARBON DIOXIDE: MEASUREMENT UNCERTAINTY CALCULATIONS
%vol
Combined uncertainty
% of value
% full scale/10V
Losses in the line (leak) 0.00 % of value
Ambient temperature dependence -0.20
0.00 % range
0.30
% full scale
Span drift
Repeatability at zero
seconds29
0.00
Repeatability at span level 0.10
%vol
RUN 1
Expanded uncertainty 1.96 0.26
N/A
%vol
RUN 1
Dependence on voltage 0.40
0.00
Range Used 30.0
%vol
Combined interference (from MCERTS Certificate)
3.08
Measured concentration
TGN M2 Allowable MU
Limit value
%
Volume or pressure flow dependence 0.00
% full scale
% full scale/10K
Performance characteristic RUN 1
-0.03
Standard deviation of repeatability at span level
Units
Expanded uncertainty (no O₂) - at 95% Confidence
%vol
Units
0.13
%vol
%vol
Uncertainty of calibration gas 2.00 % of value
0.05 %vol
%vol
Drift
% of Value
%vol
25.0
Lack of fit 0.06
RUN 1
% full scale
Combined interference
% of value/kPa
Cal gas conc. 16.0
%vol
Dependence on voltage
0.00
0.00
%vol
Losses in the line (leak) 0.00 %vol
Uncertainty of calibration gas 0.10
%vol
8.45
% of full scale
0.02
-
Performance characteristics
%vol
RUN 1 Units
Measurement uncertainty Result 8.45
% full scale
Volume or pressure flow dependence 0.10
CAT-RT (Version BY)
Page 34 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 70 of 77
Sample Runs
- -
- -
- -
General Sampling Information
NOTE: Dilution performed to achieve correct span value
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Heated Line Temperature
0.1µm Glass Fibre
% v/v 6.58
APPENDIX 2
EN 14789
OXYGEN: RESULTS SUMMARY
Heated Head Filter Used Yes
Span Gas Reference Number
Units Run 1
180
Mean
Value
Standard
Concentration
Probe Material Stainless Steel
Filtration Type / Size
Parameter
Span Gas Expiry Date 14/04/2023
Span Gas Start Pressure (bar) 100
Gas Cylinder Concentration (% v/v) 21.02
Sample Point I.D.'s A1
Thermal Oxidiser
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Span Gas Uncertainty (%) 2
Uncertainty ±% v/v 0.18 0.18
6.58
Technical Procedure CAT-TP-39
11.0345
Zero Gas Type
Number of Sampling Points Used 1 / 1
Nitrogen (5 Grade)
Parameter
1 / 1Number of Sampling Lines Used
Span Gas Type Synthetic Air (5 Grade)
CAT-RT (Version BY)
Page 35 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 71 of 77
Graphical Trend of Data
COVER ME WITH CHART/S
OXYGEN: DATA TREND
APPENDIX 2
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.01
2:2
5
12
:27
12
:29
12
:31
12
:33
12
:35
12
:37
12
:39
12
:41
12
:43
12
:45
12
:47
12
:49
12
:51
12
:53
12
:55
12
:57
12
:59
13
:01
13
:03
13
:05
13
:07
13
:09
13
:11
13
:13
13
:15
13
:17
13
:19
13
:21
13
:23
13
:25
Co
nce
ntr
atio
n (
% v
/v)
Oxygen Oxygen
- Run 1
CAT-RT (Version BY)
Page 36 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 72 of 77
Sampling Details
Quality Assurance
Average Temperature
Zero Drift 0 0 0
Zero Drift
Drift Correction Applied
Span Drift 0 0 0
Span Drift
Drift Correction Applied
Method Deviations
1
x
- - -
- - -
- - -
10.03% v/v
% v/v
Nature of Deviation
Span at Analyser (Pre)
(x = deviation applies to the associated run)
There are no deviations associated with the sampling employed.
Span Drift Units
% v/v -0.01
Allowable Zero Drift
Run 1
Run Number
2.4
25
Yes
°C
Units
Span Drift Acceptable
Yes
APPENDIX 2
-
CA
L 1
Zero at Analyser (Pre) % v/v
Temperature Acceptable -
Run 1
Zero at Analyser (Post) % v/v 0.01
± % v/v
0.01
Units Run 1
10.02
0.50
OXYGEN: SAMPLING DETAILS & QUALITY ASSURANCE
Span Gas Value
% v/v
Sampling Dates - 06/09/2018
4.0
% v/v 10.0
Zero Drift
Run Ambient Temperature Range °C 21 - 22
Zero Drift Acceptable
Test Conditions Units Run 1
Allowable Temperature < °C
0.00
12:25 - 13:25
Instrument Range
Parameter Units Run 1
Sampling Times
Yes
Allowable Span Drift ± % v/v 0.50
-
Conditioning Unit Temperature
Span at Analyser (Post) % v/v
CA
L 1
-
% 0.10
2-5% No
% -0.10
2-5% No
CAT-RT (Version BY)
Page 37 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 73 of 77
k =
RUN 1 Units
%vol
0.02
Combined interference (from MCERTS Certificate)
Dependence on voltage 0.00
Losses in the line (leak) 0.00
2.00
6.58 %vol
Combined uncertainty
%vol
Uncertainty of calibration gas 0.08
%vol
Cal gas conc. 21.0
0.04
use rep at spanStandard deviation of repeatability at zero
% of value
Uncertainty of calibration gas
%vol
Ambient temperature dependence
Expanded uncertainty 1.96 0.18 %vol
RUN 1
COMPLIANT
Units
% of value
%vol
Units
% of Value
%vol
0.00 %vol
Lack of fit
0.00
Combined interference 0.00
Performance characteristics
Standard deviation of repeatability at span level
RUN 1
Limit value
Performance characteristic
Repeatability at span level
APPENDIX 2
Requirement for SRM is that Uncertainty should be 0.5%vol absolute or 6% relative whichever is the lower, on a dry gas basis. Ref EA TGN M2.
Range Used 25.0
% full scale
Deviation from linearity
% full scale
Span drift
-
Expanded uncertainty (no O₂) - at 95% Confidence 2.73
Measured concentration
0.09 %vol
Result of Compliance with Uncertainty Requirement in M2
%vol
TGN M2 Allowable MU
OXYGEN: MEASUREMENT UNCERTAINTY CALCULATIONS
Measurement uncertainty
% full scale
%vol
Result
-0.10 % full scale
6.58 %vol
Units
-0.03
RUN 1
%vol
Volume or pressure flow dependence 0.00 %vol
Atmospheric pressure dependence %vol
Drift 0.01
0.01
% range
Dependence on voltage 0.02 % full scale/10V
Losses in the line (leak) 0.00
-
Repeatability at zero 0.02
0.26 % of value
Zero drift 0.10
% full scale/10K
% of value/kPa
% of full scale
Number of readings in measurement 30
-0.21
Atmospheric pressure dependence 0.19
Ambient temperature dependence
Volume or pressure flow dependence 0.10
%vol
Performance characteristics RUN 1 Units
Response time 41 seconds
N/A %vol
6.0 %
CAT-RT (Version BY)
Page 38 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 74 of 77
Results Summary
- -
- -
-
-
General Sampling Information
FORMAT: Number Used / Number Required
FORMAT: Number Used / Number Required
Reference Conditions
Reference Conditions are: 293K, 101.3kPa, without correction for water vapour content
Sampling & Result Information
Temperature of Olfactometric Lab -
Value
Standard BS EN 13725
- 13:00 - 13:10
Odour Presentation Mode Yes / No
Equipment Used Dynamic Dilution Probe
Calibration Status of Olfactometer
1 / 1
Sample Point I.D.'s
Times of Ofactometric Measurement
24.01
CAT-TP-30
Probe Material
APPENDIX 2
ODOUR: RESULTS SUMMARY
: 1
-CDU-1092 TO
RUN
Calculated Dilution Factor
ouE/m³
Number of Sampling Points Used
Release Point 1 - TO
A1
1 / 1
Parameter
TO
Sample ID
117.08
1.0
Stainless Steel
Date of Olfactometric Measurement - 06/09/2018
Bag 1
Upper CI
Bag 1
ouE/m³ 53.00
Lower CI
Sampling Dates - 06/09/2018
Sampling Times
ouE/m³
- 14:04
Special Process Conditions -
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
Units GEO Mean
Concentration
Parameter
Duration mins 10
0.14
Technical Procedure
53.00
Parameter
Number of Sampling Lines Used
-
25⁰C ± 3⁰C
N/A
n-butanol in N₂
Analysis Result from Laboratory ouE/m³
53ouE/m³
ID of Olfactometer
Units
NO
-
Calculated Panel Threshold ouE/m³ -
Reference Odourant Used -
Accepted Reference Value Used ppb
53
Analysis Result including Dilution Factor
CAT-RT (Version BY)
Page 39 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 75 of 77
Method Deviations
1
x x
- - - - -
- - - - -
- - - - -
Nature of Deviation Bag Numbers
(x = deviation applies to the associated bag/s)
There are no deviations associated with the sampling employed.
APPENDIX 2
ODOUR: METHOD DEVIATIONS
Anglo Beef Processors (TA Munster Proteins Waterford), Waterford
All Release Points
CAT-RT (Version BY)
Page 40 of 40
Job Number: CDU-1092, Version 1
Sample Date/s: INPUT
Industrial Emissions Licence: P0040-02
Anglo Beef Processors (TA Munster Proteins Waterford)
Waterford
Thermal Oxidiser
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 76 of 77
Summary
See report.
FOLLOW-UP ACTIONS
You are required to complete the instructions and actions, as outlined in this report, within the specified timeframe. Where required, you shall respond to actions specified in Compliance Investigations within the required timeframe.The licensee shall maintain documentary evidence, for review by the EPA, that the prescribed corrective actions were completed within the required timeframe.
(i) Compliance Investigations
You are not required to respond directly to items contained in this EPA site visit report; where an issue requires a direct response, the EPA will generate a Compliance Investigation through the EDEN system. You will receive notification when a Compliance Investigation instruction or action is generated.
(ii) Publication of reports and licensee response.
Please note that this Site Visit Report will be made available for public viewing via the EPA’s Licence Enforcement Access Portal within one day of the issue date and will be published on the Licence Details Page of the EPA’s website, www.epa.ie, that relates to your licence 60 calendar days after the issue date.
You may if you choose submit, within 45 calendar days of the issue date of this Site Visit Report, a Licensee Public Response that will be published alongside the Site Visit Report. This Response, should you wish to avail of it, provides you with an opportunity to inform the public about how you are implementing the actions set out in the report, activities underway, timescales and target completion dates. Please be aware that the content of your Licensee Public Response must be factual and should not breach the EPAs stated online publication standards.
If you wish to submit a Licensee Public Response to an EPA Site Visit Report, you should do this by clicking on the ‘Make a Response’ link on the Site Visits page in EDEN. A .pdf document containing your response can be attached and submitted from here.
(iii) Response to Site visit report
Where you do wish to respond directly to a site visit report, you should do this by generating a ‘Licensee Return’ of the type ‘Site Updates/Notifications’ and the sub-type ‘Response to EPA Report’ in EDEN.
Please note that you are required to comply with the conditions of your licence at all times, and where noncompliance occurs you must restore compliance within the shortest possible time. These actions will be verified during subsequent EPA visits.
Please quote the above Inspection Reference Number in any future correspondence in relation to this Report.
Site Visit Report - SV16024 - Anglo Beef Processors Ireland Unlimited Company Page 77 of 77