Post on 20-Feb-2016
transcript
ZXSDR B8200 L200LTE Baseband Unit
Routine Maintenance Guide
Hardware Version: HV3.10
ZTE CORPORATIONNo. 55, Hi-tech Road South, ShenZhen, P.R.ChinaPostcode: 518057Tel: +86-755-26771900Fax: +86-755-26770801URL: http://support.zte.com.cnE-mail: support@zte.com.cn
LEGAL INFORMATIONCopyright © 2014 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History
Revision No. Revision Date Revision Reason
R1.1 2014-10-30 Added BPN0A in “2.2 Version Information Collection Table”
R1.0 2014-09-18 First edition
Serial Number: SJ-20140807141023-005
Publishing Date: 2014-10-30 (R1.1)
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ContentsAbout This Manual ......................................................................................... I
Chapter 1 Overview.................................................................................... 1-11.1 Maintenance Categories ..................................................................................... 1-1
1.2 Precautions........................................................................................................ 1-1
Chapter 2 Maintenance Information ......................................................... 2-12.1 Basic Maintenance Information Collection Table ................................................... 2-1
2.2 Version Information Collection Table .................................................................... 2-2
Chapter 3 Routine Maintenance................................................................ 3-13.1 Definition of Routine Maintenance ....................................................................... 3-1
3.2 Routine Maintenance Items................................................................................. 3-1
3.3 Daily Maintenance Items..................................................................................... 3-2
3.4 Monthly Maintenance Items ................................................................................ 3-2
3.5 Quarterly Maintenance Items .............................................................................. 3-3
3.6 Semiannual Maintenance Items .......................................................................... 3-3
3.7 Annual Maintenance Items.................................................................................. 3-4
Chapter 4 Maintenance Record Table....................................................... 4-14.1 Daily Maintenance Record .................................................................................. 4-1
4.2 Monthly Maintenance Record.............................................................................. 4-2
4.3 Quarterly Maintenance Record............................................................................ 4-3
4.4 Semiannual Maintenance Record........................................................................ 4-4
4.5 Annual Maintenance Record ............................................................................... 4-4
4.6 Emergency Fault Handling Record ...................................................................... 4-6
4.7 Module Replacement Record .............................................................................. 4-7
4.8 Cable Replacement Record ................................................................................ 4-7
Glossary .......................................................................................................... I
I
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
This page intentionally left blank.
II
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
About This ManualPurposeThis manual describes how to maintain the ZXSDR B8200 L200.
Intended AudienceThis manual is intended for:
l Hardware installation engineersl Maintenance engineers
What Is in This ManualThis manual contains the following chapters.
Chapter 1, Overview Describes the routine maintenance principles, categories,
methods, and precautions of the ZXSDR B8200 L200.
Chapter 2, Maintenance
Information
Describes the templates for collecting the maintenance
information of the ZXSDR B8200 L200.
Chapter 3, Routine Maintenance Describes the routine maintenance items of the ZXSDR B8200
L200.
Chapter 4, Maintenance Record
Table
Provides maintenance record tables for your reference.
Related DocumentationThe following documents must be available before maintenance:
l Personal Health and Safety Informationl System Security Information
The following documentation is related to this manual:
l ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Hardware Descriptionl ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Product Descriptionl ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Hardware Installationl ZXSDR B8200 L200(HV3.10) LTE Baseband Unit Alarm and Notification Reference
ConventionsThis manual uses the following conventions.
I
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Danger: indicates an imminently hazardous situation. Failure to comply can result in
death or serious injury, equipment damage, or site breakdown.
Warning: indicates a potentially hazardous situation. Failure to comply can result in
serious injury, equipment damage, or interruption of major services.
II
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 1OverviewTable of Contents
Maintenance Categories.............................................................................................1-1Precautions ................................................................................................................1-1
1.1 Maintenance CategoriesMaintenance can be classified into three categories: routine maintenance, notificationhandling, and alarm handling.
Routine MaintenanceRoutine maintenance means periodical maintenance. It involves checking the operationof equipment periodically. Any problems detected during the inspection should be handledimmediately to prevent accidents.
Alarm/Notification HandlingNotification handling involves analyzing the notifications generated during systemoperation, determining whether faults exist, and taking proper measures as required.Alarm handling involves analyzing the alarms generated during equipment operation,determining whether faults exist, and taking proper measures as required. For adescription of notification and alarm handling, refer to the ZXSDR B8200 L200(HV3.10)LTE Baseband Unit Alarm and Notification Reference.
1.2 PrecautionsDuring routine maintenance, follow the precautions below:
l Keep the equipment room dry, clean, and at normal temperature. Keep rats or otheranimals out of the equipment room.
l Ensure that the primary power supply of the system is stable and reliable. Checkthe system grounding and the lightning protection grounding regularly. Ensure thatthe lightning protection system is in good condition especially before a thunderstormseason or after a thunderstorm.
l Formulate complete rules for routine maintenance. Keep a detailed duty log ofthe operations, versions, data changes, upgrade, and faults of the system for faultanalysis and handling. Ensure a shift change record is available denoting clearresponsibility.
1-1
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
l Never play games or surf the Internet on the PC. Never install, run, or copy anysoftware not related to the system on the PC. Never use the PC for other purposesnot related to work.
l Set the NetNumen passwords based on user levels and keep them open only tomaintenance personnel. Manage the passwords strictly and change them regularly.
l Receive induction training to learn about the equipment and network. Performmaintenance operations according to the instructions described in related manuals.Wear an antistatic wrist strap before touching the equipment to prevent accidentscaused by human errors.
l Do not reset the equipment, load or modify data without permission, especially theEMS database data. Data must be backed up before it is modified. A record ofthe modification should be made at the time. After data modification, the backupdata cannot be deleted until the system operates properly for a certain period of time(generally one week).
l Prepare the following common instruments and meters: flat head screwdriver, crossscrewdriver, signaling analyzer, network cable pliers, multimeter, AC power supply formaintenance, telephone line, and network cable. Test the meters regularly to ensureaccuracy.
l Inspect spare parts and accessories regularly to keep them in stock and in goodcondition. Protect them against moisture and mould. Separate the spare parts andaccessories from the replaced parts and accessories and label them respectively.Replenish the common spare parts and accessories as they are used up.
l Keep any software and documentation that may be used during maintenance in aspecified handy place for use when required.
l Lighting in the equipment room should meet maintenance requirements. Repair anybroken lights in time.
l Solve any detected problems in time. For any problems that cannot be handled,contact the local ZTE office.
l Place the contact information of the local ZTE office in a handy place and make itknown to all maintenance personnel. Update the contact information regularly.
Danger!
Power supply inspection and adjustment must be performed by professionals. Otherwise,injury, death, and equipment failures may occur.
Warning!
Data cannot be modified or synchronized without permission of the person in charge.Otherwise, major accidents may occur.
1-2
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 2Maintenance InformationTable of Contents
Basic Maintenance Information Collection Table.........................................................2-1Version Information Collection Table...........................................................................2-2
2.1 Basic Maintenance Information Collection TableTable 2-1 lists the equipment information to be collected during maintenance for theZXSDR B8200 L200.
Table 2-1 Basic Maintenance Information Collection
Basic Maintenance Information Collection
ZXSDR B8200
L200 name
North latitude
ZXSDR B8200
L200 type
East longitude
ZXSDR B8200
L200 No.
Altitude
ZXSDR B8200
L200 ID
(configured on
the OMC)
City/County Telephone
number of
the equipment
room
Position of
the equipment
room
Daisy chain
mode adopted
(description
of the link
structure)
2-1
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
2.2 Version Information Collection TableVersion information of the ZXSDR B8200 L200 should be collected and recorded formaintenance. Table 2-2 lists the ZXSDR B8200 L200 version information to be collected.
Table 2-2 Version Information Collection
Module Version
CC
CC16B
CCE1
BPL1
BPL1A
BPN0A
BPN0
FS5
CR0
SA
SE
UES
UCI
FA
PM
Remarks:
2-2
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 3Routine MaintenanceTable of ContentsDefinition of Routine Maintenance ..............................................................................3-1Routine Maintenance Items........................................................................................3-1Daily Maintenance Items ............................................................................................3-2Monthly Maintenance Items........................................................................................3-2Quarterly Maintenance Items......................................................................................3-3Semiannual Maintenance Items .................................................................................3-3Annual Maintenance Items .........................................................................................3-4
3.1 Definition of Routine MaintenanceRoutinemaintenancemeans to perform a preventive inspection regularly on the equipmentto ensure the equipment operates properly for a long time.
Routine maintenance mainly covers the following two types:
l Regular inspection and testing
Inspect and test the operation, functions, major performance indicators, and hardwarecondition of the ZXSDR B8200 L200 regularly through OMC operations, or withappropriate instruments and meters according to the technical specifications andrequirements for the equipment parts.
l Regular checking and cleaning
Check the hardware of the ZXSDR B8200 L200 and its auxiliary devices. If anyproblem is detected, adjust, fix, or replace the faulty parts immediately to ensurethat the hardware remains intact. Regularly maintain and clean the parts that arevulnerable or must be dust-free. Regularly clean the major parts of other peripheralequipment for proper operation.
Work out a reasonable maintenance schedule and perform routine maintenance onschedule.
3.2 Routine Maintenance ItemsRoutine maintenance includes various regular checks and maintenance tasks that ensurethe equipment operates in the best condition to meet the service requirements of usersand to prevent potential failures.
Routine maintenance of the equipment includes but is not limited to the following items:
l Inspection of the operating environment of the equipment
3-1
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
l Collection of performance statisticsl Alarm system maintenancel Data backupl Spare parts inspectionl Board maintenancel Log inspectionl Inspection of the grounding and lightning protection systemsl Power supply inspectionl Inspection of the antenna feeder systeml Preparation before holidays
3.3 Daily Maintenance ItemsTable 3-1 lists the daily maintenance items of the ZXSDR B8200 L200.
Table 3-1 Daily Maintenance Items
Item Sub-item Action
Handling alarms Check all the alarms that are generated since the
last inspection on the EMS and categorize and
handle the alarms based on alarm levels.
Checking
alarms and
notifications
Handling notifications Analyze the notifications that occur frequently.
Ignore common notifications.
Handling common faults Handle the common faults, such as transmission
failures and board faults.
Troubleshoot-
ing
Handling user complaints Analyze and handle the problems that users
complain about, for example, network quality.
3.4 Monthly Maintenance ItemsTable 3-2 lists the monthly maintenance items of the ZXSDR B8200 L200.
Table 3-2 Monthly Maintenance Items
Item Action
Checking the temperature and
humidity
Check the temperature and humidity of the equipment room.
Check the temperature through the alarm management system of
the OMC and measure the humidity with a hygrometer.
Checking the operation of
modules
Check the operation of modules through the alarm management
system of the OMC. For any faulty modules, diagnose the faults
through the diagnostic test system.
3-2
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 3 Routine Maintenance
Item Action
Checking the voice and data
services
Perform the tests with a terminal on site. Observe and survey the
services in each sector. Check whether there are disconnection,
interruption, or throughput errors.
Checking the operation of the
power module
Check the power supply of the ZXSDR B8200 L200.
Checking the grounding and
lightning protection systems
Inspect the operation of the grounding and lightning protection
systems and check whether the connections are secure.
3.5 Quarterly Maintenance ItemsTable 3-3 lists the quarterly maintenance items of the ZXSDR B8200 L200.
Table 3-3 Quarterly Maintenance Items
Item Action
Checking the Standing Wave
Ratio (SWR) of the antenna
feeder
Check whether or not there are SWR alarms reported on the EMS.
Measure the grounding resistance with a grounding resistance
tester, and check whether or not the resistance value is correct.
Measuring the grounding
resistance value and checking
the grounding cable Check whether or not the connectors of each grounding cable are
loose or aging.
Checking the water resistance
and grounding connection of
the antenna feeder connector
and the lightning protection
grounding kit
Check whether or not the outside surface is in good condition.
If necessary, remove the insulating tape and perform a further
inspection. Seal the connection again with the insulating tape after
the inspection.
Checking whether or not the
antenna is installed securely
and inspecting the pitch angle
and azimuth of the directional
antenna
Check whether or not the antenna is beyond the scope specified
by network planning due to wind blowing. Adjust the antenna with
such tools as spanners and angle gauges. Note that screw nuts
with a proper force.
Checking the lightning
protection
Check whether or not the connection of the lightning protection
grounding cable is secure, and check the rust resistance of the
connection.
3.6 Semiannual Maintenance ItemsTable 3-4 lists the semiannual maintenance items of the ZXSDR B8200 L200.
3-3
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
Table 3-4 Semiannual Maintenance Items
Item Action Remark
Lightning protection
and grounding
Check the working ground of the
equipment.
Check the protective ground of the
equipment room.
Check the grounding trunk line of
the eNodeB.
Check the lightning protection
ground of the building.
Test all the grounding resistances.
Perform an additional check before
and after nature disasters such as
typhoons and thunderstorms.
3.7 Annual Maintenance ItemsTable 3-5 lists the annual maintenance items of the ZXSDR B8200 L200.
Table 3-5 Annual Maintenance Items
Item Action
Checking the cleanness and
airtightness of the cabinet
Clean the outside surface of the cabinet with a vacuum cleaner or
towel. Pay special attention to the switch or power supply and do
not touch them by mistake during cleaning. Open the cabinet and
check whether or not there is water in it and whether or not the joint
between the top and the bottom covers of the cabinet are airtight.
3-4
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 4Maintenance Record TableTable of ContentsDaily Maintenance Record .........................................................................................4-1Monthly Maintenance Record .....................................................................................4-2Quarterly Maintenance Record...................................................................................4-3Semiannual Maintenance Record...............................................................................4-4Annual Maintenance Record ......................................................................................4-4Emergency Fault Handling Record .............................................................................4-6Module Replacement Record .....................................................................................4-7Cable Replacement Record........................................................................................4-7
4.1 Daily Maintenance RecordTable 4-1 Daily Maintenance Record
Date: Year Month Day
Duty hour: From to Handover from: Handover to:
Active alarm handling record of the eNodeB
eNodeB No. Alarm content Alarm start
time
Alarm end
time
Remark
Abnormal history alarm record of the eNodeB
eNodeB No. Abnormal alarm content and handling Remark
Abnormal history notification record of the eNodeB
eNodeB No. Abnormal notification content and handling Remark
4-1
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
User complaint handling
eNodeB No. Complaint content and handling Remark
Handover information:
Team leader verification:
4.2 Monthly Maintenance RecordTable 4-2 Monthly Maintenance Record
Time: Year Month Day Hour Maintained by:
Item Description Action Remark
Are the location
parameters configured
for the eNodeB the
same as the actual
parameters?
Is the rack of the
equipment clean?
Is the cable rack
secure?
Are the fiber connectors
and other cable
connectors in good
contact?
Are the indicators of the
equipment operating
properly?
Are the temperature
and humidity correct?
4-2
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 4 Maintenance Record Table
Are the voice and
data services in good
condition?
Are the grounding and
lightning protection
systems in good
condition?
Are the spare parts and
accessories in stock
and in good condition?
□ Yes □ No
Team leader verification:
4.3 Quarterly Maintenance RecordTable 4-3 Quarterly Maintenance Record
ZXSDR B8200 L200 Name: Time: Year Month Day
Maintained by:
Item Result Remark
Is the ZXSDR B8200 L200
module operating properly?
□ Yes □ No
Are the data services in good
condition?
□ Yes □ No
Is the power module operating
properly?
□ Yes □ No
Are the grounding and lightning
protection systems in good
condition?
□ Yes □ No
Is the grounding resistance
value correct and the grounding
cable in good condition?
□ Yes □ No
4-3
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
Are the water resistance and
grounding connection of the
antenna feeder connector
and the lightning protection
grounding kit in good condition?
□ Yes □ No
Is the dust-proof assembly of
the fan module cleaned?
□ Yes □ No
Fault description and
troubleshooting:
Unsolved problems:
Team leader verification:
4.4 Semiannual Maintenance RecordTable 4-4 Semiannual Maintenance Record
Time: Year Month Day Hour Maintained by:
Item Result Remark
Is the working ground of the
equipment connected securely?
□ Yes □ No
Is the protective ground of the
equipment room connected
securely?
□ Yes □ No
Is the grounding trunk line of the
eNodeB connected securely?
□ Yes □ No
Measure the grounding resistance. Value:
4.5 Annual Maintenance RecordTable 4-5 Annual Maintenance Record
Equipment name: Time: Year Month Day
Maintained by:
4-4
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 4 Maintenance Record Table
Equipment name: Time: Year Month Day
Item Result Remark
Is the cabinet clean? □ Yes □ No
Are the temperature and humidity correct? □ Yes □ No
Is the module operating properly? □ Yes □ No
Are the voice and data services in good con-
dition? □ Yes □ No
Is the power module operating properly? □ Yes □ No
Are the grounding and lightning protection
systems in good condition? □ Yes □ No
Is the SWR of the antenna feeder correct? □ Yes □ No
Is the grounding resistance value correct and
the grounding cable in good condition? □ Yes □ No
Are the water resistance and grounding con-
nection of the antenna feeder connector and
the lightning protection grounding kit in good
condition? □ Yes □ No
Is the antenna installed securely and are the
pitch angle and azimuth of the directional an-
tenna correct? □ Yes □ No
Is the lightning protection system for the an-
tenna feeder in good condition? □ Yes □ No
Fault description and troubleshooting:
Unsolved problems:
Team leader verification:
4-5
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
4.6 Emergency Fault Handling RecordTable 4-6 Emergency Fault Handling Record
Emergency Fault Handling Record
Site name: Handled by:
Occurrence time: Handling time:
Fault source:
□ Customer complaint □ Alarm system reporting □ Found during routine maintenance □ Other
Fault type:
Fault description:
Action:
Result:
Comment of the person in charge:
4-6
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
Chapter 4 Maintenance Record Table
4.7 Module Replacement RecordTable 4-7 Module Replacement Record
Module Replacement Record
eNodeB No.: Maintained by:
Module
Name
Slot Number Failure Time Replace-
ment Time
SN of the Faulty
Module
SN of the
Replacement
Module
4.8 Cable Replacement RecordTable 4-8 Cable Replacement Record
Cable Replacement Record
eNodeB No.: Maintained by:
Cable Name Cable
Connection
Position
Failure
Time
Replace-
ment Time
SN of the Faulty
Cable
SN of the
Replacement
Cable
4-7
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
ZXSDR B8200 L200 Routine Maintenance Guide
4-8
SJ-20140807141023-005|2014-10-30 (R1.1) ZTE Proprietary and Confidential
GlossaryBPL- Baseband Processing for LTE
CC- Control and Clock Module
CCE- Control Channel Element
FA- Fan Array
FS- Fabric Switch Module
OMC- Operation & Maintenance Center
PM- Power Module
SA- Site Alarm
SE- Site Alarm Extender
UCI- Universal Clock Interface
UES- Universal Ethernet Switch Board
I