Status report on segmented mesh microbulk

Post on 22-Feb-2016

29 views 0 download

Tags:

description

RD51 Common fund project. Status report on segmented mesh microbulk. Fransisco Aznar 1 , Theopisti Dafni 1 , Martyn Davenport 3, Rui De Oliveira 3 , Esther Ferrer Ribas 2 , Serge Ferry 3 , Theo Geralis Fransisco J. Iguaz 1 , Thanos Kalamaris , Mariam Kebbiri 2 ,Thomas Papaevangelou 2. - PowerPoint PPT Presentation

transcript

Status report on segmented mesh microbulk

1University of Zaragoza, 2IRFU/CEA, 3CERN, 4NCSR Demokritos,

Fransisco Aznar1, Theopisti Dafni1, Martyn Davenport3, Rui De Oliveira3, Esther Ferrer Ribas2, Serge Ferry3, Theo Geralis Fransisco J. Iguaz1, Thanos Kalamaris, Mariam Kebbiri2 ,Thomas

Papaevangelou2

RD51 Common fund project

6th February 2014, RD51 Collaboration Meeting

• Develop a 2D low mass intrinsic X-Y detector• Strategy used up to now (CAST, MIMAC, NTOF…)

Disadvantages:

• In the limit of no diffussion, the 2D capabilities are lost

• Charge collection in X-Y is not completely equivalent

• Complexity in the manufacturing of a multilayer stack microbulk

Motivations

X-strips

Y-strips

•Signal X-Y completely correlated

•Minimisation of the mass budget

•Coupled to autotrigger electronics Very low threshold

Interest: rare event detection experiments, neutron beam imagers…

Intrinsic true 2D Microbulks

Segmented mesh microbulk

Present design

1st batch: February 2012Active area ~ 38 x 38 mm2, Cu strips, pitch 1mm, strips interspacing 100 μm, amplification

gap 50 μm could not hold HV, only a few strips were operational

2nd batch: November 2012

New production technique, 4 Micromegas prototypes Hold HV, No spectrum from an 55Fe source, pitch 1mm, strips interspacing 100 μm, amplification gap 50 μm

3rd batch: September 2013

Evolution

5 Detectors manufactured with different holes diameters: 2 with 45µm and 3 with 60 µm. Pitch is 1 mm and strip interspacing reduced to 40 µm

Manufacturing: first the x-strips then the mesh holes and finally the y strips.No holes on top of the x-strips gaps.

3rd Batch

Evolution

50 55 60 65 70 7510

12

14

16

18

20

22

24Resolution=fct(Ea)

Ea(kV/cm)

Reso

lutio

n (%

)

48 53 58 63 68 73 781E+02

1E+03

1E+04

1E+05 Gain=fct(Ea)

ubulk_standard_8_D40_P90ubulk1

Ea(kV/cm)

Gai

n

First characterisations (3rd batch)

Ar + 5% IsobutaneReading the mesh (PA Ortec+ Shaper+MCA)55Fe source

Testing the x-strips with Gassiplex electronics

12% FWHM

Testing the x-strips with Gassiplex electronics

•First operational segmented microbulks have been produced: they behave as standard microbulks (high gains, Eres=12% reached)

• Differences of behaviour (Eres) between 40 and 60 µm holes: in the 60 µm there was an alignment problem during manufaturing.

•HV front end card has been validated

•Characterisation on going

Next steps:

•Read Y signals with Gassiplex electronics

•Test with autotrigger electronics: VMM1/AGET

•Optimise design

•Built a large detector with connector: NTOF neutron beam profiler

Conclusions and perspectives

BACK UP