Post on 12-Jun-2020
transcript
T F W
604.549.9379604.549.9555f l u x w e r x . c o m
Row-Configuration-Summary12 2017
PAGE1 of 2
All rights reserved. © Fluxwerx Illumination Inc 2013 Due to continuing product improvements, specifications and dimensions are subject to change without notice. Consult www.fluxwerx.com for most current technical information.
®
Luminaire Type
Project
Product
Notes
LENGTH PF NP 4 ft 6 ft 8 ft
4 ft 1 1 1 - -
6 ft 1 1 - 1 -
8 ft 1 1 - - 1
10 ft 2 1 1 1 -
12 ft 2 1 1 - 1
12 ft 2 1 - 2 -
14 ft 2 1 - 1 1
Suspended LEDTypical Row Configurations *
6-complete
pf np
8-complete
pf np
4-end
pf
6-end
pf np
8-end
pf
4-end
np pf
pf
6-end
pf np
6-end
4-complete
pf np
pf np
8-end
pf
6-end
PF = Power Feed Canopy Location
NP = Suspension Canopy Location
Aircraft cable suspension points: 4 ft fixtures 48” (1219 mm) o.c. 6 ft fixtures 72” (1829 mm) o.c 8 ft fixtures 96” (2438 mm) o.c.
NOTE: NO ELECTRICAL CONNECTIONS REQUIRED AT FIXTURE LEVEL All fixtures arrive on site prewired with LV powercord factory installed All middle fixtures arrive onsite with joints factory preinstalled All end(s) fixtures arrive onsite with endcaps factory preinstalled
4-complete
pf np
4-complete
pf np
* Refer to separate product specification datasheets for detailed dimensions of endcaps, driver enclosures, canopies, and wiring.
* Optional 12ft configuration. Consult factory.
TYPICAL ROW CONFIGURATIONS
Sept 2013Suspended Row Configs
PAGE2 of 2
All rights reserved. © Fluxwerx Illumination Inc 2013 Due to continuing product improvements, specifications and dimensions are subject to change without notice. Consult www.fluxwerx.com for most current technical information.
®
Integrated Driver, Mounting, Power Feed + Suspension *
Power Feed Canopy Suspension Canopy
(S) SURFACE Hard Lid Ceilings
Integral driver with mounting, power feed, suspension + canopy suitable for exposed surface conduit or recessed J-boxes
0-10V Dim
120-277V
Lutron
347V
50% BiLevel
Battery Pack
0-10V Dim
120-277V
Lutron
347V
50% BiLevel
Battery Pack
Perpendicular or Parallel Retrofit Method
(D) DRYWALL New or Retrofit
Integrated driver, power feed and mounting suspension points suitable for GWB or plaster thicknesses of < 0.875" (22 mm)
(R) REMOTE Hard Lid Ceilings
External remote mounted driver. Power feed and suspension points suitable for exposed conduit or recessed junction boxes
0-10V Dim
120-277V
Lutron
347V
50% BiLevel
Battery Pack
Power Feed Multivolt 120 -277V driverDetached MethodHorizontal or Vertical
(G) GRID ON or OFF Grid
Integrated clip, driver, power feed and mounting suspension points
suitable for accessible ceiling grid heights of < 1.75" (44 mm)
0-10V Dim
120-277V
Lutron
347V
50% BiLevel
Battery Pack
LENGTH PF NP 4 ft 6ft 8 ft
16 ft 2 1 - - 2
18 ft 3 1 1 1 1
18 ft 3 1 - 3 -
20 ft 3 1 1 - 2
22 ft 3 1 - 1 2
24 ft 3 1 - - 3
6-end 6-middle
pf nppf
6-end
pf
pf np pf
8-end8-end
pf np
8-end
pf
6-end4-middle
pf
pf
4-middle
pf np pf
8-end8-end
pf np
8-end
pf
8-end6-middle
pf
8-end
pf
8-middle
pf np pf
8-end
* Refer to separate product specification datasheets for detailed dimensions of endcaps, driver enclosures, canopies, and wiring.
* Optional 18ft configuration. Consult factory.