1 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
System Limits (Trunks)
1. Control facilities single CCU 245 addresses max.
Delegate units, chairman's units, and interpreters desks are counting for 1. Channel selectors are passive units and using one reserved address for all.
Reserved addresses are not a part of the 245!
2. Power handling Capacity Central Control Unit 130 Watt Extension Power Supply 255 Watt
3. Cable length After 100 meter of system cable the signal needs to be regenerated.
Units with the regenerating signal-outlets: Trunk Splitter & Tap-Off unit (Trunk Splitter protected) Extension power supply (Tap-off outlets only)
The number of serial tap-off connections from the CCU to the last tap-off in a branch must not exceed 4.
250 meter max. from the CCU to the last unit in the trunk.
I&U Instructions
2 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Discussion Unit with fixed microphone 2.75 W
Discussion Unit 2.75 W
Discussion Unit with Channel selector 2.9 W
Discussion Unit Dual 2.8 W
Discussion Unit Dual with channel selector 3.15 W
Discussion Unit with voting 3.05 W
Discussion Unit with voting and channel selector 3.20 W
Concentus Chairman unit 4.2 W
Concentus basic unit 3.4 W
Concentus with channel selector 3.7 W
Concentus full function 4.2 W
Voting Unit 1.0 W
Dual Delegate Interface 4.5 W Inclusive all connected FM panels.
Power Consumption in Watt
I&U Instructions
3 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter’s Desk 3.6 W
Channel selector unit 0.9 W
Data distribution unit 2.0 W
Extension Power Supply 0.8 W
Trunk Splitter 1.3 W
Tap-Off Unit (Trunk Splitter Protected)
1.4 W
Watt value includes the 2 meter (6.5 ft.) unit-cable.
Audio Expander Analogue 7.6 W
Audio Expander Digital 6.0 W
Cobra net interface 10.5 W
Optical Network splitter 3.9 W
Fiber Interface (POF/GOF or GOF/POF) 4.6 W
Power Consumption in Watt
I&U Instructions
4 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Power handling capacities
Central Control Unit Central Control Unit Extension Power SupplyDCN-CCUB DCN-CCU DCN-EPS
65 W 65 W
65 W 65 W
130 W
65 W
Trunk Tap-off
85 W 85 W
255 W
85 W
I&U Instructions
65 W 65 W
130 W
5 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Max. number of units within 100M from CCU
Max. per trunk: 18 Interpreter desks 50 Channel selectors
or
Max. all trunks: 36 Interpreter desks 100 Channel selectors
or
Central Control Unit
Cable length per outlet to the last unit 100M
1 n 50
1 n 18
I&U Instructions
6 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Max. number of units connected to the CCU
Max. per trunk: 18 Interpreter desks 70 Channel selectors
or
Max. all trunks: 36 Interpreter desks 140 Channel selectors
or
* * Max. Cable length 100m
Central Control Unit
1 n 18
* Tap-off outlets.Tap-off outlets.
1 5051 70TS
I&U Instructions
7 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Max. number of units within 100M from EPS
Max. per trunk: 23 Interpreter desks 50 Channel selectors
or
Max. all trunks: 69 Interpreter desks150 Channel selectors
or
Trunk Tap-off
Cable length per outlet to the last unit 100M
Extension Power Supply
1 n 23
1 n 50
1 n 50
I&U Instructions
8 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Max. number of units connected to the EPS
Max. per trunk: 23 Interpreter desks 90 Channel selectors
or
Max. all trunks: 69 Interpreter desks 270 Channel selectors
or
Trunk Tap-off
Extension Power Supply
1 5051 90
1 5051 90
1 n 23
Max. Cable length 100m
* Tap-off outlets.Tap-off outlets.
* *
* *
I&U Instructions
LBB4114
LBB4114
9 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Trunk Outlet & Tap-Off Outlets
For Trunk-cable splitting with regenerating the digital signal.
*
Tap-off outlets which regenerating the digital signal.Tap-off outlets which regenerating the digital signal.
* *
Extension Power Supply
* *
Trunk-in Trunk-out
Trunk Splitter&
Tap-Off unit (trunk splitter
protected)
I&U Instructions
10 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Using the Tap-Off unit (Trunk Splitter Protected)
* *
* Tap-off outlets with a limitation of 4,5 Watt.Tap-off outlets with a limitation of 4,5 Watt.
* *
I&U Instructions
LBB4115 LBB4115
11 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Tap-Off Limitations
Trunk Splitter
Tap-off
Tap-off Trunk-lineLoop Through
Trunk-line
1st Tap-off
1st Tap-off
3rd Tap-off
2nd Tap-off
2nd Tap-off
3rd Tap-off
4th Tap-off
4th Tap-off
5th Tap-off
Extension Power SupplyCentral ControlUnit
I&U Instructions
12 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Maximum Cable Lengths 250M
Central ControlUnit
RegenerativeTap-offTrunk Splitter
ExtensionPower Supply
RegenerativeTap-offTrunk Splitter
ExtensionPower Supply
I&U Instructions
13 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Longest Extension Cable example
The length of cable used in a system hasa direct influence on the load of a
system.
The second in- line trunk- splitter has two extension cables connected to it, with lengths of 20 m and 50 m.
When determining the cable length of a Trunk-outlet or Tap-off outlet, the longest extension cable only is taken in to account.
Therefore, the total extension cable lengthfrom a single Trunk-outlet of the CCU is calculated as 10+50= 60 m (196.8 ft.)
10 m (32.8 ft.)
50 m (164 ft.)20 m (65.6 ft.)
Central ControlUnit
I&U Instructions
14 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Power calculation Example-1
TrunkOutlet
Longest ExtensionCable length
Power consumptionwithout
ext. cable correction
Power consumption with
ext. cable correction
1 65 m. (213.2 ft.) 46.6 Watt 63.9 Watt
2 40 m. (147.4 ft.) 54.0 Watt 64.8 Watt
Total power in use 128.7 Watt
*
Max. Cable length 100m
Central Control Unit
12x 12x12x 12x
TS
10x 5x
40m.
50m.15m.
1 2
To EPSSee next slide
* TS
Example
LBB4114
15 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Power calculation Example-2
TrunkOutlet
Longest ExtensionCable length
Power consumptionwithout
ext. cable correction
Power consumption with
ext. cable correction
3 60 m. (196.8 ft.) 63.4 Watt 84.5 Watt
4 40 m. (131.2 ft.) 70.6 Watt 84.7 Watt
5 35 m. (131.2 ft.) 72.0 Watt 84.3 Watt
Total power in use 253.5 Watt
Example
Trunk Tap-off
Extension Power Supply
10x 20x15x 24x
20x 20x22x 15x
10x35m.
10x
Max. Cable length 100m
* 40m.20m.
20m.20m.
TS
TS
3 4 5
*
LBB4114
LBB4114
16 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Cable correction graph
I&U Instructions
17 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
System Limits (Optical)
1. Maximum number of nodes is 63
2. Maximum number of optical devices is 16
3. Optical Plastic Fiber length is maximum 50 Meter
4. Maximum Optical cable length is depending of the number of nodes in the system
I&U Instructions
18 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Basic Central Control Unit 0
Central Control Unit 2
Audio Expander LBB4402/00 1
Digital Audio Expander 1
CobraNet Interface 1
Optical Network Splitter 1
Fiber Interface POFGOF & GOFPOF 0
Integrus Transmitter 4 channels 1
Integrus Transmitter 8 channels 2
Integrus Transmitter 16 channels 4
Integrus Transmitter 32 channels 8
Number of nodes per optical unit
I&U Instructions
19 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Fiber interface without address
The fiber interface is used to: convert from plastic optical fiber
(POF) cable to glass optical fiber (GOF) cable and vice versa.
cover distances of more than 50 m in the optical network.
I&U Instructions
LBB4414/10 LBB4414/10
20 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Nodes Cable lengths graph
I&U Instructions
21 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Optical connections
I&U Instructions
CobraNet
Central Controle Unit
Interface
Audio Expander
Integrus Transmitter
22 DCNNG SA SD Design CalcST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
System Design and Calculation