The Park2 Wake Model - Documentation and Validation
Rathmann, Ole Steen; Hansen, Brian Ohrbeck; Hansen, Kurt Schaldemose; Mortensen, Niels Gylling;Murcia Leon, Juan Pablo
Publication date:2018
Document VersionPublisher's PDF, also known as Version of record
Link back to DTU Orbit
Citation (APA):Rathmann, O. S., Hansen, B. O., Hansen, K. S., Mortensen, N. G., & Murcia Leon, J. P. (2018). The Park2Wake Model - Documentation and Validation. DTU Wind Energy E Vol. 160
The Park2 Wake Model - Documentation and Validation
Ole Steen Rathmann, Brian Ohrbeck Hansen, Kurt S. Hansen, Niels Gylling Mortensen, Juan Pablo Murcia Leon1 1Vestas Power Solutions Report DTU Wind Energy E-0160 April 2018
The Park2 Wake Model - Documentation and Validation Report DTU Wind Energy E-0160 April 2018 By Ole Steen Rathmann, Brian Ohrbeck Hansen, Kurt S. Hansen, Niels Gylling Mortensen, Juan Pablo Murcia Leon1 1Vestas Power Solutions Copyright: Reproduction of this publication in whole or in part must include the customary
bibliographic citation, including author attribution, report title, etc. Cover photo: Fog-stripes in the wakes of the Horns Rev 1 Wind Farm Published by: Department of Wind Energy, Frederiksborgvej 399 Request report from:
www.dtu.dk
ISSN: [0000-0000] (electronic version) ISBN:
[987-87-93549-28-9] (electronic version)
ISSN: [0000-0000] (printed version) ISBN: [987-87-93549-28-9] (printed version)
Preface
This report describes the revised Park-model, Park2, and the validation and calibration of it. The Park2 model is implemented the WAsP 12 software package. Roskilde, April 2018 Ole Steen Rathmann Senior Researcher
Content
Summary .......................................................................................................................... 6
1. Introduction and Background .................................................................................. 7
2. The consistency flaw of Park1 ................................................................................ 7 2.1 The NOJ formulation .............................................................................................................. 7 2.2 Park1 formulation ................................................................................................................... 8
3. Park2: The consistent formulation. ......................................................................... 9 3.1 Surface reflection ................................................................................................................. 10
4. Selected Off-shore Wind Farm Data for Comparison ............................................ 10
5. Qualitative comparison of the effect of Park2-features to offshore windfarm data. 12 5.1 Test results .......................................................................................................................... 13 5.2 Findings from the qualitative comparisons of the effect of the Park2-features ..................... 16
6. Quantitative validation and calibration of Park2 based on offshore wind farms. .... 17
7. Qualitative Validation of Park2 against offshore wind farm data. .......................... 17 7.1 Findings from the qualitative validations. ............................................................................. 21
8. Calibration of Park2 for on-shore conditions vs. Park1 ......................................... 22
9. Conclusion ............................................................................................................ 23
References ..................................................................................................................... 23
Acknowledgements ......................................................................................................... 24
6
Summary
The WAsP Park wake model has been revised to ensure physical consistency. For off-shore conditions the revised Park2 wake model has been calibrated and validated against production data from a number of off-shore wind farms. For on-shore conditions, the Park2 wake model has been calibrated against predictions by the original Park model for a number of on-shore wind farms. The calibrations have resulted in recommended values for the wake decay constant of the revised Park2 wake model.
7
1. Introduction and Background The DTU Wind Energy Wind Atlas and Analysis and Application Program (WAsP) has for a long time used the Park wake model – hereafter referred to as Park1 - to calculate wake effects within wind farms. Park1, originally a stand-alone program (Katic et al., 1986), (Sanderhoff, 1983), is based on the so-called NOJ wake model (Jensen N.O., 1983) that uses a simple top-hat speed profile in the wake downwind of a wind turbine, the wake expanding simply linearly like a cone. However, for the interaction of wakes inside a wind farm, Park1 does not follow the NOJ wake model strictly, but uses an empirical procedure. The empirical procedure consists of an unconventional formulation of the speed deficit contribution from a certain in-farm wind turbine (in-farm: a turbine itself in the wake of another turbine), and a wake superposition model based on a quadratic summation rule for adding speed deficit contributions. In addition, wake interaction with the ground or water surface is represented by simple reflection. Others have adapted the same formulation (Nygaard 2015). The empirical procedure, however, has a consistency flaw since it will predict a ghost-turbine1 to have an unphysical effect on turbines downwind of it. Thereby a ghost-turbine will also have an unphysical effect on the total production of the wind farm. Park2 is a revision of the Park1-model, still with the simple wake representation by a top-hat profile based on the NOJ-model, but with a changed speed deficit and wake interaction formulation that removes the consistency flaw.
2. The consistency flaw of Park1 The original Park1 model was based on the NOJ-wake model (Jensen 1983), and below we will give the most relevant details from this formulation.
2.1 The NOJ formulation In his original publication, N.O.Jensen (Jensen, 1983, eq.2) states the following approximate expression for the speed in the wake at a distance x downwind of a single turbine:
2
0( ) 1 2 = − +
RV x U aR kx
(2.1.1a),
corresponding to a speed deficit of
2
0 0( ) ( ) 2 ∆ = − = + RV x U V x U a
R kx (2.1.1b)
Here a is the factor of influence with 2 1 1 ta C= − − where Ct denotes the thrust-coefficient2.
(In his publication Jensen actually uses the optimum value a=1/3). R of course denotes rotor radius =½D, and k is a wake decay constant. A top-hat speed-deficit profile is assumed where inside the wake of diameter ( )+ −i iR k x x the speed deficit has a value as given by eq. (2.1.1b)
but is zero outside the wake.
1 Ghost-turbine: A turbine with zero or very small thrust and power production for all wind speeds. 2 Thrust on the rotor T = ½ρair ArotorV2*Ct
8
Further, in the same publication (eq.7) N.O.Jensen states the following approximate expression for the incident wind speed at rotor #2 in a single row along the wind speed under the impact of the two upwind turbines #0 and #1:
2
2 1
0 0 1,2
1 1 (1 2 )
= − − − + ∆
inc incV V RaU U R k x
(2.1.2)
This corresponds to a speed deficit of
( )2
2 0 2 0 11,2
(1 2 )
∆ = − = − − + ∆
inc inc inc RV U V U V aR k x
(2.1.3)
Here it should be observed that Jensen’s eq.(7) is stated as an approximation to the resulting reduced wind speed – i.e. eq.(2.1.3) above should be seen as an approximation to the total speed deficit originating from the wakes of turbine #0 and #1.
2.2 Park1 formulation In the original Park model (Katic et al. 1986; Sanderhoff 1993 ) as well as in the present WAsP/Park model (WAsP8-WAsP11) the wake speed deficit originating from a certain in-Park turbine #i, based on the NOJ-wake model (Jensen 1983), is taken to be
( )2
0( ) 1 ( )2 ( )
∆ = − − + −
inc inc ii i t i
i i
DV x U V C VD k x x
(2.2.1)
Here x is the downwind coordinate (xi being the x-coordinate of turbine #i) and Viinc is the incident wind speed on rotor #i, and as in the NOJ-model a top-hat speed-deficit profile is assumed. It should be noticed that the turbine thrust coefficient Ct is evaluated on basis of the incident wind speed at a turbine (NOT on basis of the free wind speed). For the incident wind speed at some turbine #j, downwind of turbine #i, a factor is included to account for partial overlap between the wake and the rotor area of turbine #j:
,( ) ( )overlapi jeff
i j i j rotorj
AV x V x
A∆ = ∆ (2.2.2)
The resulting incident wind speed at a rotor #j is found using an empiric quadratic summation rule for all the speed deficits of all relevant wakes (originating from upwind turbines):
20 ( )
upwind turbinesincj i j
iV U V x= − ∆∑ (2.2.3)
As wake interaction with the surface is represented as simple reflection, the sum in the above eq.(2.2.3) includes wakes originating from real turbines as well as from “reflected turbines”, i.e. turbines with the same horizontal positions as the real turbines but with a formal hub-height of –hi (hi being the hub height of real turbine #i). Others have adopted that same formulation ( e.g. Nygaard, 2015). The above empirical formulation has the obvious unphysical consequence – inconsistency – that a “ghost-turbine” will have a speed-deficit impact just from the fact that it has a non-zero incident speed deficit, i.e. if 0 0inc
iU V− > . It is obvious that a physical formulation should fulfil
the requirement that the speed deficit impact from some turbine should tend to zero when the Ct of that turbine tends to zero.
9
Now, simple inspection reveals that eq.(2.2.1) is in fact identical to Jensen’s eq.(2.1.3), and it is tempting to think that the inspiration to use eq.(2.2.1) is in fact Jensen’s eq.(7) – or eqs.(2.1.2) and (2.1.3) above. However, where Jensen’s eq.(7) and eq.(2.1.3) is an approximation to the total speed deficit (from wakes #0 and #1), eq.(2.2.1) is used as the contribution from just a single upwind turbine: the total resulting speed deficit is obtained by combining the contributions from the individual wakes from upwind turbines using quadratic summation, eq.(2.2.3). Thus, by using eqs.(2.2.1)-(2.2.3) the impact of upwind turbines is in fact included twice. Consequently, we do not consider it correct to use formulation (2.2.1). The relative success of the inconsistent formulation (2.2.1)-(2.2.3) could be due the use of quadratic summation, which mainly considers the large contributions and thus counteracts the double inclusion of upwind wake effects as described above.
3. Park2: The consistent formulation. As stated previously, in the Park2 model we stick to the simple NOJ single-wake model with its top-hat profile and its linear wake expansion. Now, contrary to Park1, the Park2 model takes the partial effect of a certain turbine to be equal to the wake effect downwind of that turbine in the following virtual situation: (1) had there been no other turbines, and (2) had the virtual free wind speed been the actual incident wind speed at that turbine. Thus, based on eq.(2.1.1b), the partial speed deficit originating from a certain turbine #i is
( )2
( ) 1 1 ( )2 ( )
∆ = − − + −
inc inc ii i t i
i i
DV x V C VD k x x
(3.1 a)
For easy notation we introduce the wake diameter ( ) 2 ( )= + −wakei i iD x D k x x , thus
( )2
( ) 1 1 ( )( )
inc inc ii i t i wake
i i
DV x V C VD x x
∆ = − − −
(3.1 b)
This formulation (3.1) ensures consistency since a Ct tending to zero will imply that ΔVi tends to zero as well. When estimating the combined effect of overlapping wakes Park2 uses classical perturbation theory, thus assuming that, at some point, the speed-deficit effects from the individual turbines are sufficiently small that they may be simply added. In other words, we apply a linear wake superposition. So, taking into account the effect of partial overlap between a wake and a rotor we find the resulting incident wind speed at a turbine #j
,0 ( )= − ∆∑
overlapupwind turbinesi jinc
j i j rotori j
AV U V x
A (3.2)
Here Arotor and Aoverlap denote the rotor area and the area of the part of the partial wake overlapping the rotor, respectively.
10
3.1 Surface reflection The Park1 model (Katic et al., 1986), (Sanderhoff, 1983) used surface reflection of the individual wakes to represent the interaction with ground- or water-surface. The reflected wakes were then treated as “additional wakes” added up together with “true” wakes in the wake superposition procedure. However, use of surface reflection together with the consistent formulation and using linear wake superposition (eqs. (3.1), (3.2)) seems problematic. Initial investigations (section 4.2) showed that very large values of the wake decay constant would have to be assumed to get results similar to what has been observed in large off-shore wind farms. In addition, CFD-studies (Ott, 2011, Ott, 2014) have indicated that the wake-interaction with the surface is not described correctly by simple reflection since the wake expansion is a diffusion-like process occurring in a flow with a log-like vertical profile. Consequently, the speed deficit must tend to zero at the surface, which is not fulfilled by a reflection model. Hence, in Park2 wake surface reflections are simply omitted.
4. Selected Off-shore Wind Farm Data for Comparison
Operational data from three “primary” Danish and Swedish off-shore wind farms, including production details for individual turbines, have been used for qualitative validation and calibration of the Park2 model:
a) The Horns Rev wind farm, 1.Jan. 2005 – 31.Dec. 2009; b) the Nysted wind farm, 24.May 2004 – 16.Nov.2006; and c) the Lillgrund wind farm. 1.Jan. 2008 – 31.Dec. 2012.
Data from a “secondary“ wind farm was included, but only as a reference regarding total wind farm production: Anholt wind farm, Jan.2013-June 2015.
Wind farm Country Number of turbines
Turbine Wind farm rated power (MW)
Comparison use Rated
power (MW)
Hub height (m)
Rotor diameter (m)
Primary Wind Farms Horns Rev 1 DK 80 2 69 80 160
Turbine power production
Nysted DK 72 2.33 69 82 167.8 Lillgrund S 48 2.3 65 92.6 110.4 Secondary wind farm Anholt DK 111 3.6 81.6 120 399.6
W.F.power production, for reference only
The locations and the layouts of the wind farms are shown below.
11
Figure 1. Locations of the wind farms used in this study. Figure 1. The locations of the wind farms are indicated (produced by Google Earth).
Figure 2. The Horns Rev wind farm layout with selected wind directions.
Figure 3. The Nysted wind farm layout with the selected wind directions.
Figure 4. The Lillgrund wind farm layout with the selected wind directions.
Figure 5. The Anholt wind farm layout.
WT01
WT02
WT03
WT04
WT05
WT06
WT07
WT08
WT11
WT12
WT13
WT14
WT15
WT16
WT17
WT18
WT21
WT22
WT23
WT24
WT25
WT26
WT27
WT28
WT31
WT32
WT33
WT34
WT35
WT36
WT37
WT38
WT41
WT42
WT43
WT44
WT45
WT46
WT47
WT48
WT51
WT52
WT53
WT54
WT55
WT56
WT57
WT58
WT61
WT62
WT63
WT64
WT65
WT66
WT67
WT68
WT71
WT72
WT73
WT74
WT75
WT76
WT77
WT78
WT81
WT82
WT83
WT84
WT85
WT86
WT87
WT88
WT91
WT92
WT93
WT94
WT95
WT96
WT97
WT98
423 424 425 426 427 428 429 430
Easting (km) UTM Zone32
6147
6148
6149
6150
6151
6152
Nor
thin
g (k
m)
222
270
242
WT11WT21
WT31WT41
WT51WT61
WT71WT81
WT12WT22
WT32WT42
WT52WT62
WT72WT82
WT13WT23
WT33WT43
WT53WT63
WT73WT83
WT14WT24
WT34WT44
WT54WT64
WT74WT84
WT15WT25
WT35WT45
WT55WT65
WT75WT85
WT16WT26
WT36WT46
WT56WT66
WT76WT86
WT17WT27
WT37WT47
WT57WT67
WT77WT87
WT18WT28
WT38WT48
WT58WT68
WT78WT88
WT19WT29
WT39WT49
WT59WT69
WT79WT89
673 674 675 676 677 678Easting (km) UTM Zone 32
6046
6047
6048
6049
6050
Nor
thin
g (k
m)
Nysted
263
278
320
A-01
A-02
A-03
A-04
A-05
A-06
A-07
B-01
B-02
B-03
B-04
B-05
B-06
B-07
B-08
C-01
C-02
C-03
C-04
C-05
C-06
C-07
C-08
D-01
D-02
D-03
D-04
D-06
D-07
D-08
E-01
E-02
E-03
E-04
E-06
E-07
F-02
F-03
F-04
F-05
F-06
G-02
G-03
G-04
G-05
H-02
H-03
H-04
358.5 359 359.5 360 360.5 361 361.5Easting (km) UTM Zone 33
6152.5
6153
6153.5
6154
6154.5
6155
6155.5
Nor
thin
g (k
m)
Lillgrund180
120
222255
Row BRow C
Row A
Row B
A01A02A03A04A05A06A07A08A09A10A11A12A13A14A15A16
A17A18
A19A20
A22A23
A24A25
A26A27
A28A29
A30A31
B01C01
C02
C03
C04
C05
C06
C07
C09
C10
C12
C31
D01E01
F01
F02
F03
F04
F05
F06
F07
F08
F09
F10
F11
F12
F13
F14
F23F24
F25
F26F27
F28F29
G01H01
I01
I02
I03
I04
I05
I07
I08
I10
I28
J01K01
L01L02L03
L04L05
L06
M01P01P02
P03P04
P05P06
P07P08
P09P10
P11P12
P13
P15P16
P17
P19P20
P21P22
P23P24
P25P26
P27P28
630 632 634 636 638 640 642 6446264
6266
6268
6270
6272
6274
6276
6278
6280
6282
6284
6286
6288
Easting (km) UTM Zone 32
Nor
thin
g (k
m)
12
For each of the three primary wind farms, a number of flow cases have been selected and used for validation and calibration. For all three wind farms the following three speed-cases were used:
Hub-height Wind Speed 8.0 +/- 0.5 m/s 10.0 +/- 0.5 m/s 12.0 +/- 0.5 m/s
Each wind speed case was used in combination with 3 or 4 wind direction-cases: Hub-height Wind Direction Horns Rev 1 222.0 +/- 7.5 ° 242.0 +/- 7.5 ° 270.0 +/- 7.5 ° Nysted 263.0 +/- 7.5 ° 278.0 +/- 7.5 ° 320.0 +/- 7.5 ° Lillgrund 120.0 +/- 7.5 ° 180.0 +/- 7.5 ° 222.0 +/- 7.5 ° 255.0 +/- 7.5 °
5. Qualitative comparison of the effect of Park2-features to offshore windfarm data
As an initial test the above primary off-shore wind farm flow cases were used in a comparative study to see the separate effects of the 3 features introduced relative to Park1: a) Consistent formulation; b) Linear wake-superposition; c) Omission of surface reflection. Predictions were made for these flow cases in four steps: by the Park1-model, by hybrid models, where first feature a) and then feature b) are introduced; and by the Park2 model (all features a) b) and c) introduced):
Step Speed-deficit Formulation
Wake superposition Wake Surface- reflection
0 Park1 standard
Inconsistent Quadratic YES
I Park hybrid B Consistent Quadratic YES II Park hybrid C Consistent Linear YES III Park2 Consistent Linear NO
The following wake decay constants were used: Park1 and Park hybrid B: Park1 recommended value (k =0.05); Park hybrid C: the value giving closest agreement (k =0.14); Park2: the value, later found to be recommended (k =0.06). The model predictions were averaged over the same speed- and direction intervals as those used for sampling observations within each flow case. The results are shown below.
13
5.1 Test results
Figure 6. Horns Rev 1 – Effect of Park2-features a), b) and c), introduced one by one, compared to Park1 and to observations.
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 222 d
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 222 d
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 222 de
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 242 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 242 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 242 deg.
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 50
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 270 deg., Row
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 270 deg., Row
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 270 deg., Row
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 50
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 270 deg., Row
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 270 deg., Row
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 270 deg., Ro
Observations
Park1, k=0.05
Park1-B, k=0.05
Park1-C, k=0.14
Park2, k=0.06
Park1/Park2 Test 8m/s, 222 deg.
Park1/Park2 Test 8m/s, 242 deg.
Park1/Park2 Test 10m/s, 242 deg.
Park1/Park2 Test 12m/s, 222 deg.
Park1/Park2 Test 10m/s, 222 deg.
Park1/Park2 Test 12m/s, 242 deg.
Park1/Park2 Test 8m/s, 270 deg., Row4
Park1/Park2 Test 10m/s, 270 deg., Row4,
Park1/Park2 Test 12m/s, 270 deg., Row4
Park1/Park2 Test 8m/s, 270 deg., Row8
Park1/Park2 Test 10m/s, 270 deg., Row8
Park1/Park2 Test 12m/s, 270 deg., Row8
14
Figure 7. Nysted – Effect of all Park2-features, a)+b)+c), compared to Park1 and to observations. Only the results of step 0 and step III are shown.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 263 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 263 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 263 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 278 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 278 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 278 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 60
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 320 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 320 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 320 deg.
Observations
Park1, k=0.05
Park2, k=0.06
15
Figure 8. Lillgrund – Effect of Park2-features. (To continue on the following page.)
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 120 deg.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 120 deg.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 120 deg.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 250
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 180 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 250
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 180 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 180 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 180 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 180 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 180 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 250
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 222 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 222 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 222 deg., Row
Observations
Park1, k=0.05
Park1-B, k=0.05
Park2, k=0.06
180 deg., Row C
180 deg., Row B
180 deg., Row B
180 deg., Row B
180 deg., Row C
180 deg., Row C
222 deg., Row A
222 deg., Row A
222 deg., Row A
16
Figure 8. Lillgrund – Effect of Park2-feature a) (Park1-B) and features a)+b)+c) (Park2) compared to Park1 and to observations. Only the results of steps 0, I and III are shown.
5.2 Findings from the qualitative comparisons of the effect of the Park2-features
• The consistent speed-deficit formulation in combination with quadratic wake superposition (Park hybrid B) does not represent properly the way the turbine power production decreases downwind into the wind farm. Park hybrid B predicts the power production to drop from the first to the second turbine – but thereafter nearly without any further decrease; this is in contradiction to the observations which show a gradual decrease in turbine power production downwind along a turbine row. When introducing linear speed deficit summation the predicted downwind decrease of turbine power production resembles the observations to a much higher degree.
• The consistent speed-deficit formulation in combination with linear speed-deficit summation rule, but still with wake surface reflection (Park hybrid C), requires a very high wake decay constant value (k=0.14) in order to match the observed power production deficits. However, from eddy-diffusivity arguments (Rathmann, 2017) the k -value should have a clearly lower value like the ones found to match observations when surface reflection is omitted. This – together with the aerodynamic arguments already presented in section 3.1 – supports the decision to omit surface reflection in the Park2 model.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 222 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 250
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 222 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 222 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 8m/s, 255 deg., Row
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 20
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 10m/s, 255 deg., Ro
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park1/Park2 Test 12m/s, 255 deg., Row
Observations
Park1, k=0.05
Park1-B, k=0.05
Park2, k=0.06
222 deg., Row B
255 deg., Row 5
222 deg., Row B
222 deg., Row B
255 deg., Row 5
255 deg., Row 5
17
6. Quantitative validation and calibration of Park2 based on offshore wind farms.
This validation and calibration study (Murcia, 2017b) was based on production time series from the offshore wind farms Horns Rev, Nysted, Lillgrund and Anholt. The time series were preprocessed to avoid impact from the situations where one or more turbines were out of operation. The Park2-model was represented by a number of farm-specific look-up tables of total wind farm production as a function of hub-height wind speed and wind direction. The look-up tables covered a k-value range of 0.05 ... 0.16. A so-called Bayesian calibration procedure (Kennedy, 2001; Murcia, 2017a) was applied to deduce the k-value to be recommended. In short, for each single observation of wind farm production a probability density function, PDF, for k was calculated on basis of the look-up tables. By then combining the PDFs for all production observations, taking into account the uncertainty of these observations, a “total” Gaussian-like PDF for k was constructed, resulting in a mean value and a spread of the k-value, see table 7.1 and fig. 9.
Table 8.1. Results for the Bayesian calibration of k. The wind field over the Horns Rev 1, Nysted and Lillgrund wind farms may be assumed rather homogeneous, whereas the wind field over the Anholt wind farm is known to have large gradients due to variations in the distance to nearest coast – gradients not taken into account when producing the look-up tables for the Anholt wind farm. The k-value to recommend for offshore wind farms is therefore based on the results for Horns Rev, Nysted and Lillgrund only, as given in table 8.1. It should be noted that the deduced k-value for Anholt – although differing somewhat from the recommended value – within error bars in fact overlaps with the recommended value.
7. Qualitative Validation of Park2 against offshore wind farm data.
A validation for off-shore with a series of candidate k-values (0.05, 0.06, .., 0.10), including the recommended value, was performed using the observations for the off-shore wind farm flow
Wind farm µ σ Horns Rev 1 0.061 0.005 Nysted 0.057 0.007 Lillgrund 0.064 0.004 Recom-mended value
All 0.06 0.006
Anholt 0.051 0.006
Wake decay constant k
PDF(
k)
Figure 9. PDF of the k-value (Bayesian calibration)
18
cases listed in section 4. In the model predictions speed- and direction-averaging were applied over the same speed- and direction intervals as those used for sampling observations within each flow-case. The results of this validation are shown in the following plots.
Figure 10. Horns Rev 1. Qualitative validation of Park2 with various k-values.
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 222 deg.
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 222 deg.
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 222 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 242 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 242 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0Re
lativ
e Tu
rbin
e po
wer
Downwind distance [m]
Park2 Test 12 m/s, 242 deg.
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 270 deg., Row4
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 270 deg., Row4
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 270 deg., Row4
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 270 deg., Row8
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 270 deg., Row8
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
-1000 0 1000 2000 3000 4000 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 270 deg., Row8
Observations
Park2, k=0.05
Park2, k=0.06
Park2, k=0.07
Park2, k=0.08
Park2 , k=0.09
Park2, k=0.10
19
Figure 11. Nysted. Qualitative validation of Park2 with various k-values.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 263 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 263 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 263 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 278 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 6000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 278 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0 600
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 278 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 320 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000.0
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 320 deg.
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-1000.0 0.0 1000.0 2000.0 3000.0 4000.0 5000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 320 deg.
Observations
Park2, k=0.05
Park2, k=0.06
Park2, k=0.07
Park2, k=0.08
Park2 , k=0.09
Park2, k=0.10
20
Figure 12. Lillgrund. Qualitative validation of Park2 with various k-values. (To continue on the following page.)
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 120 deg.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 120 deg.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 120 deg.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 180 deg., Row B
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 180 deg., Row B
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 180 deg., Row B
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 180 deg., Row C
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 180 deg., Row C
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 180 deg., Row C
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 222 deg., Row A
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 222 deg., Row A
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 222 deg., Row A
Observations
Park2, k=0.05
Park2, k=0.06
Park2, k=0.07
Park2, k=0.08
Park2 , k=0.09
Park2, k=0.10
21
Figure 12. Lillgrund. Qualitative validation of Park2 with various k-values.
7.1 Findings from the qualitative validations. The comparisons of the results from the Park1 model (section 5) and from the Park2 model (this section) to the observations indicate: • The Park2-model with k=0.06 gives an over-all agreement with observations which is at
least as good as for the Park1-model with the recommended k-value of 0.05 for offshore wind farms (figures. 10-12).
• The qualitative validation also reveals that the optimal k-value clearly depends on the wind speed and wind direction. Thus, for a number of the lowest-speed cases – e.g. Horns Rev 222° and 270°, k=0.08 or even 0.09, would give the best fit. For some of the highest speed cases (12 m/s) – e.g. Lillgrund 180° and 255° - k=0.05 would give the best fit. This indicates, that for high wind speeds the model exaggerates the effect of the lower turbine thrust-coefficient on the wake speed deficit, thus leading to an under-prediction of the wake effects. Presumably, the inability of Park2 to model all speed and directional effects is due to the simplifications in the model.
• However, it should be recalled that the qualitative validation only concerns a limited number of wind directions, typically along wind farm “rows”. Therefore the calibration of the over-all k-value cannot be based on these comparisons alone; in addition it is needed to take all available production data into account – as is done in the section 6, “Quantitative validation and calibration based on offshore wind farms”.
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 222 deg., Row B
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 222 deg., Row B
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000 2500
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 222 deg., Row B
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 8m/s, 255 deg., Row 5
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 10m/s, 255 deg., Row 5
0.100
0.200
0.300
0.400
0.500
0.600
0.700
0.800
0.900
1.000
1.100
-500 0 500 1000 1500 2000
Rela
tive
Turb
ine
pow
er
Downwind distance [m]
Park2 Test 12m/s, 255 deg., Row 5
Observations
Park2, k=0.05
Park2, k=0.06
Park2, k=0.07
Park2, k=0.08
Park2 , k=0.09
Park2, k=0.10
22
8. Calibration of Park2 for on-shore conditions vs. Park1
No proper on-shore wind farm operational data have been readily available for validation and calibration of Park2 for on-shore conditions. Instead, a ‘calibration’ has been undertaken, using AEP-calculations by Park1 for a number of existing or projected on-shore wind farms. Thus a recommended Park2 wake decay constant k for on-shore conditions is found, that gives essentially the same AEP results as those obtained by using the original Park model, Park1, with its on-shore standard k-value (0.075).
14 different on-shore wind farms were used (Mortensen, 2015; Mortensen, 2017):
Wind farm name
Country Rated power Index Wind farm
name Country Rated power
Index
CREYAP 1 GB 14 × 2MW 1 Capel Cynon (6 wind farms)
GB 18 × 2MW 7
CREYAP 2 GB 22 × 1.3MW 2 6 × 3MW 8
Napier ZA 27 × 3.45MW 3 7 × 2MW 9
Jasseines (2 wind farms)
FR 6 × 2MW 4 9 × 2MW 10
4 × 1.8MW 5 4 × 3MW 11
La Ventosa MX 51 × 2MW 6 6 × 0.81MW 12 Vredensburg ZA 34 × 3.6MW 13 Ras Ghareb EG 100 × 3.02MW 14
Table 8.1. Onshore wind farms used for the calibration.
The result of the fitting-procedure to find the matching Park2 k-value is shown in figure 8.1 below. The error bars indicate the k-values where the Park2 production calculation differs ±0.15% from Park1.
The resulting recommended k-value (average value) with associated uncertainty is given in table 8.2.
Figure 8.1. Best-fit wake decay constants for Park2 vs. Park1.
k µ 0.088
σ 0.009
Table 8.2. Resulting recommended k-value with uncertainty.
0.05
0.06
0.07
0.08
0.09
0.1
0.11
0.12
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15Wak
e ex
pans
ion
coef
ficie
nt k
Wind Farm index
23
9. Conclusion The Park wake-model for wind farms has been modified. In the modified Park-model, Park2, we introduce a consistent formulation for the speed-deficit in the wakes. In addition, a more physically based superposition rule is introduced: linear superposition; and for aerodynamic reasons, wake reflection in the surface is omitted. For offshore conditions, the Park2 model was calibrated and evaluated by means of a number of observed production data sets from offshore wind farm flow cases. The calibration resulted in a recommended value for the wake decay constant k. With this recommended k-value Park2 was found to produce predictions at least as close as Park1 to observed offshore wind farm productions. Observed production data from on-shore wind farms for calibration and evaluation were not readily available. Consequently, for on-shore conditions Park2 has been calibrated against Park1-predictions of annual energy production (AEP) for a number of on-shore wind farms, resulting in a recommended value for the wake decay constant k for onshore conditions. The recommended wake decay constant values are given in table 9.1 below:
Windfarm type Offshore Onshore
k µ 0.06 0.09
σ 0.006 0.009
Table 9.1. Recommended wake decay constant values with associated uncertainty.
References [1] Jensen, N.O. (1983): A Note on Wind Generator Interaction. Risø-M-2411 .Risø National
Laboratory, Roskilde, Denmark.
[2] Katic, I., Højstrup, J., Jensen, N.O.(1986): A Simple Model for Cluster Efficiency. EWEA Conference and Exhibition 7-9-October 1986, Rome, Italy, paper C6.
[3] Sanderhoff, P. (1983): Park – Users’ Guide, A PC-program for calculation of wind turbine park performance. Risø-I-668(EN), Risø National Laboratory, Roskilde, Denmark.
[4] Højstrup, J. et al. (1993): Full Scale Measurements in Wind-Turbine Arrays. Nørrekær Enge II. CEC/JOULE. Risø-I-684(EN). Risø National Laboratory, Roskilde, Denmark.
[5] Ott, S., Berg, J. and Nielsen, M. (2011): Linearized CFD Models for Wakes. DTU, Risø National laboratory, Report Risø-R 1772(EN)
[6] Ott, S. and Nielsen, M. (2014): Developments of the offshore wind turbine wake model Fuga. DTU Wind Energy, Report E-0046.
[7] Nygaard, N. (2015): Derivation of the Jensen wake model. DONG Energy. Note. Private communication.
[8] Rathmann O. (2017): Estimation of the Wake Decay Constant from Eddy Diffusivity Theory. Research note, DTU Wind Energy.
24
[9] Kennedy, M.C., O’Hagan, A. (2001): Bayesian calibration of computer models. Journal of the Royal Statistical Society: Series B (Statistical Methodology), 63(3), 425-464.
[10] Murcia, J.P. et al. (2017a): Uncertainty quantification in wind farm flow models. PhD thesis, DTU Wind Energy.
[11] Murcia, J.P. et al. (2017b): Wake Model Calibration Based On SCADA Data Considering Uncertainty In The Inflow Conditions. Private communication.
[12] Mortensen,N.G. Nielsen, M., and Ejsing Jørgensen, H. (2015). Comparison of Resource and Energy Yield Assessment Procedures 2011-2015: What have we learned and what needs to be done? EWEA 2015, Paris, France, 17-20 November.
[13] Mortensen, N.G. (2017). Personal communication. DTU Wind Energy.
Acknowledgements Wind farm operational data were kindly made available by DONG Energy (now Ørsted) and Vattenfall.