Post on 19-Sep-2020
transcript
EMERSON BLUE 6” THERMOSTATS
BLUE 6” - UNIVERSAL AND SINGLE STAGE MODELS - 6 SQ. IN. DISPLAYBlue 6” Models Offer More Premium Features than Higher Priced Competitive Touchscreen Models.
F145-1328Indoor Remote Sensor
F145-1378Outdoor Remote Sensor
FEATURES•Universalmodelsquicklyconfigureforsinglestage,multi-stageorheatpumpand heat pump duel fuel systems - programmable or non-programmable •Easy Reader model is easy to read and easy to use. •Commercial offersoccupieddamperoreconomizercontrolandlockingcoverand subbase•Staging control for nearly all conventional and heat pump systems•Single stage model compatible with all single stage systems low voltage, 750 mV and 3-wire zone systems. 1F97-0671 not pictured.•HeatPumpdualfueloptioneliminatestheneedforafossilfuelkit.•Automaticchangeoveroption.•Programfanoptions.•Keypadlockoutandsetpointtemperaturelimitoptions.• Indoorremotesensorforaveragingoption.•OutdoorremotesensoroptiononselectUniversalmodelsforoutdoortemperature reading and dual fuel balance point or outdoor thermostat function (select models) •Dualpower-hardwireand/orbatteryorTripower-hardwireand/orbatterywith system assist.
PARTS AND ACCESSORIES See end of this section for additional parts and accessories
•F145-1328—IndoorRemoteSensor•F145-1378—OutdoorRemoteSensor•F61-2600—Wallplate81/8”W X 53/8”H•F61-2634—Wallplate61/2”W x 5”H(ororderF61-2648–6packofF61-2634)•F29-0198—LockingThermostatGuard-ClearPlastic•F29-0220—LockingThermostatGuard-Metal,SolidBase•AdditionalThermostatGuards—seepages24-25forquickselectionoptions
1F95EZ-0671
1F95-0671
SPECIFICATIONSElectrical Rating:Hardwire . . . . . . . . . . . . . . . . . . . . . . . . 20-30 VAC, NEC Class II 50/60HzBattery Power. . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DCTerminal Load. . . . . . . . . . . . . . . . . . . . 1.5 A per terminal, 2.5 A maximum all terminals combinedSetpoint Range. . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)Rated Differentials, Universal Models: Fast SlowHeat(Single Stage/Multi-Stage) . . . . . . 0.6°F 1.2°FCool (Single Stage/Multi-Stage) . . . . . . 1.2°F 1.7°FPump . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2°F 1.7°FEmer. Heat . . . . . . . . . . . . . . . . . . . . . . 1.2°F 1.7°FRated Differentials - Single Stage Models: Fast SlowHeat . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.6°F 1.2°FCool . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2°F 1.7°FOperating Ambient . . . . . . . . . . . . . . . . 32 to +105°F (0 to +41°C)Operating Humidity. . . . . . . . . . . . . . . . 90% non-condensing max.Shipping Temperature Range. . . . . . . . -4 to +150°F (-20 to 65°C)Dimension. . . . . . . . . . . . . . . . . . . . . . . 43/16”H x 61/2”W x 15/8”D (17/8”D – Commercial model )
1F95-0680
THER
MO
STAT
S
www.white-rodgers.com10
EMERSON BLUE 6”THERMOSTATS
UNIVERSAL STAGING/HEAT PUMP THERMOSTATS – EMERSON BLUE 6” THERMOSTATS
SingleStage
Multi-Stage
HeatPump Programs Model Applications
Ther
mos
tat P
ower
Sou
rce*
Selectable Performance FeaturesComfort and Convenience
Features Terminals
Stages Heat/Coolby System
Program Options
Periods Per Day Options
ModelNumber
Gas
/ O
il / E
lect
ric
3 W
ire Z
one
Valv
e
Mill
ivol
t Com
patib
le
Hum
idity
Con
trol
(H)-H
umid
ity /
(D)-D
ehum
idify
Aut
o C
hang
eove
r
Prog
ram
mab
le F
an
Ener
gy M
gt. R
ecov
ery
Dua
l Fue
l Hea
t Pum
p C
ontr
ol(L
)-Log
ic /
(O)-O
utdo
or S
enso
rK
eypa
d Lo
ckou
t(T
)-Tot
al /
(P)-P
artia
lSe
t-Poi
nt T
empe
ratu
re L
imits
Adj
usta
ble
Max
/Min
Indo
or R
emot
e Se
nsor
sM
ax. N
umbe
r + T
herm
osta
tAv
erag
e an
d/or
Wei
ghte
d
Out
door
Rem
ote
Sens
or
Dis
play
Siz
eSq
uare
inch
es
Ligh
ted
Dis
play
Coo
l Sav
ings
Mem
ory
Bac
k-U
p(P
)-Per
man
ent /
(B)-B
atte
ry
1/1 2/2 4/2 7, 5+1+1, Ø
4, 2, Ø 1F95-0680Universal
Commercial
3 3 3 B, H, PA
3 3 3 O‡ T, P 3 1 + 1 1t 6.0 3*** 3 P RC, RH, C, G, Y, Y2, W/E, W2, O/B, L, +,
S, -, 6, A11/1 2/2 4/2 7, 5+1+1,
Ø4, 2, Ø 1F95-0671
Universal3 3 3 B, H,
PA3 3 3 O‡ T, P 3 1 + 1 1t 6.0 3*** 3 P RC, RH, C, G, Y, Y2,
W/E, W2, O/B, L, 6, +, S, -
1/1 2/2 4/2 Ø, 7 2, 4 1F95EZ-0671Easy Reader
3 3 3 B, H, PA
3 3 3 L 3 6.0 3*** 3 P RC, RH, C, G, Y, Y2, W/E, W2, O/B, L
SINGLE STAGE THERMOSTAT – EMERSON BLUE 6” THERMOSTAT
SingleStage
Multi-Stage
HeatPump Programs Model Applications
Ther
mos
tat P
ower
Sou
rce*
Selectable Performance FeaturesComfort and Convenience
Features Terminals
Stages Heat/Coolby System
Program Options
Periods Per Day Options
ModelNumber
Gas
/ O
il / E
lect
ric
3 W
ire Z
one
Valv
e
Mill
ivol
t Com
patib
le
Hum
idity
Con
trol
(H)-H
umid
ity /
(D)-D
ehum
idify
Aut
o C
hang
eove
r
Prog
ram
mab
le F
an
Ener
gy M
gt. R
ecov
ery
Dua
l Fue
l Hea
t Pum
p C
ontr
ol(L
)-Log
ic /
(O)-O
utdo
or S
enso
rK
eypa
d Lo
ckou
t(T
)-Tot
al /
(P)-P
artia
lSe
t-Poi
nt T
empe
ratu
re L
imits
Adj
usta
ble
Max
/Min
Indo
or R
emot
e Se
nsor
sM
ax. N
umbe
r + T
herm
osta
tAv
erag
e an
d/or
Wei
ghte
d
Out
door
Rem
ote
Sens
or
Dis
play
Siz
eSq
uare
inch
es
Ligh
ted
Dis
play
Coo
l Sav
ings
Mem
ory
Bac
k-U
p(P
)-Per
man
ent /
(B)-B
atte
ry1/1 1/1 7, 5+1+1,
Ø4, 2, Ø 1F97-0671 3 3 3 B, H,
PA3 3 3 T, P 3 1 + 1 1t 6.0 3*** 3 P RC, RH, C, W, Y, G,
O, B, L, 6, +, S, -
* H=Hardwired(RequiresCommon) ‡ If F145-1378 outdoor remote sensor is not used, install manufacturers B,H=BatteryPoweredorHardwired fossilfuelkitforDualFuelapplications B = Battery Powered *** Optional Continuous Display Light w/ Hardwire connection PA = Power Saving Battery Assist t Only one (1) remote sensor may be used – either Indoor or Outdoor
?PAGES 134-143
TECHNICAL HELP1F97-0671 ..................... WiringDiagrams/Configuration ...............See pages 134-1351F95EZ-0671.................WiringDiagrams/Configuration ...............See pages 136-1371F95-0671 ..................... WiringDiagrams/Configuration ...............See pages 138-1401F95-0680 .....................WiringDiagrams/Configuration ...............See pages 141-143
THER
MO
STAT
S
www.white-rodgers.com 11