Post on 15-May-2018
transcript
TRi ChloRine GeneRaToR
insTRuCTion Manual and WaRRanTy CaRd
1
Part: Qty: description:
a. 1 TRiPowerpack
b. 1 Chlorinegeneratingcell
c. 1 Powerpackbracket
d. 2 Reducingbushes
This KiT ConTains:
1
WelCoMe To ZodiaC
CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.
iMPoRTanT infoRMaTion
YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY.
2 3
ZodiaC Believes in safeTy fiRsT
AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.
GeneRal WaRninGs
Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.
Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.
Keepequipmentoutofreachofchildren.
Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.
Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.
Beforeperforminginstallation,disconnectallpower.
Forswimmingpools,Australianstandardsrecommendaminimumof1PartPerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.
ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.
2 3
ZodiaC Believes in safeTy fiRsT
Child safeTy
Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.
Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.
Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.
eleCTRiCal haZaRd
Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.
TheZodiacTRIPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.
Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.
Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).
Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.
Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.
Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.
4 5
insTallaTion Guide
ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRiChlorinegenerator.
PosiTioninG The PoWeR PaCK
1. Locateasuitablespaceforthepowerpackbracket.Itshouldbeinstallednofurtherthan1.8metresawayfromthecell-ideallyinafiltrationshedorclosetothefiltrationequipment.
PLEASENOTE:iffixingtoapostitmusthaveawaterproofpanelfitted(behindtheunit),atleast450mmwideand470mmhigh.
2. Usingscrewsprovided,fastenthebracketsecurelytothewallandpositionthepowerpackonthebracket.Plugintopowerpoint,butdon’tturnonthepower.
PosiTioninG The ChloRine GeneRaTinG Cell
PLEASENOTE:Thecellshouldalwaysbethelastdeviceplacedonthewaterpipe(Inthereturnlinetothepool).
3. Ensurethecellisplacedhorizontally,withtheInletpipeconnectingtothefittingclosesttothecelllead.
4. Usingscrewbarrelfittings(supplied),attachthecelltothepipe.Ifusing40mmpipe,youwillneedtofitthecellusingthereducingbushes(alsosupplied).
5. Whenconnectingtheleadfromthepowerpacktothecellmatchupthecorrespondingcoloursandpins,thenfittheendcap.
(Note:EitherREDwirecanbeconnectedtoeitherREDpinontheelectrode.)
6. PlugyourpoolpumpintotheoutletsocketinthebottomoftheTRi(thiswillallowtheTRitimertocontrolthefiltrationtimes)
7. OnceallconnectionsaretogetherpressthemainspowerswitchtoON.
4 5
naviGaTion BuTTons
UsethefollowingUIbuttonstoaccessandselectallmenusandcommands:
on/off
TurnUIpoweron/off.
uP/doWn
Scrollup/downwithincurrentmenutohighlightaspecificmenucommand.
Menu/BaCK
Entersintothemainmenu,andusedtogobacktopreviousmenu.
seleCT/enTeR
Select/enterscurrenthighlightedmenucommand.Displaythenextrelatedcommandoractivatetheselectedfunction
6 7
usinG inBuilT CloCK and TiMeRs
Whenitcomestochlorination,everypoolisdifferent.Togetwhat’srightforyou,youwillneedtosettheunit’sclockandtimers.
seTTinG The CloCK
1. Switchpoweron.
2. Waitforthestart-upsequencetocomplete.
3. Pressthe buttontoentertheMAINMENU.
4. Use / buttonsandscrolltoSETCLOCK.
5. Press .
6. Use / buttonstosetthehours.
7. Press tosavethehours.
8. Usethe / buttonstosettheminutes.
9. Press tosavetheminutes.
TRiwillthenreturntotheMAINMENU.
10.Press toreturntotheoperatingscreen.
NOTE:Thetimeisdisplayedin24Hourformat
6 7
TuRninG ChloRine GeneRaTion on
ThechlorinegenerationoftheTRicanbecontrolledinanumberofways:
1. Manuallysettoanoutputlevel,withtheoperatingtimesdeterminedbyanexternaltimer.
2. Usingthein-builttimersontheTRiunit(referto‘TheTimers’)
3. Usingaconnectiontoanexternalcontroller(referto‘Connectingtoacontroller’).
Toturnthechlorinegenerationonmanually,presstheON/OFFbutton.Theoutputlevelcanbesetasdescribedin‘SettingtheChlorineOutput.’NOTE:Forsafetyreasons,theTRichlorinegeneratorwillcontinuallydosechlorineforamaximumof30hoursifleftrunningwithno‘OFF’time–unlessconnectedtoenexternalcontroller.Afterthistime
theTRiwillswitchto‘OFF’.
The TiMeRs
TheZodiacTRichlorinegeneratorcomeswithtwoinbuilttimersthatswitchthefiltrationandchlorinationsystemonandoffasrequired.
Duringswimmingseason,considerrunningthesystemforaround8hoursaday.Thiscanbeincreasedto10hoursduringperiodsofveryhotweather.
Inwinter,itmayonlybenecessarytorunyourpool’sfiltrationsystemfor4hoursaday.Theseshorterperiodsofactivitywilllengthenthelifeoftheunit’selectrode.
Forbestyearroundresults,settheunittooperateduringthecoolerhoursoftheearlymorning,eveningorwhenswimmersareusingthepool.
PRoGRaMMinG The TiMeRs
Toactivatethetimer,youwillneedtoenterbothanONandOFFtime.IfnoOFFtimeisentered,thechlorinegeneratorwillswitchoffatthedefaulttimeof12:00am(0:00).
Youwillknowthatavalidtimehasbeenenteredwhena“T”SymbolisdisplayedinthetoprighthandcorneroftheLCDdisplaywhentheunitisdisplayingthe‘operatingscreen’.
usinG inBuilT CloCK and TiMeRs
8 9
usinG inBuilT CloCK and TiMeRs
Toprogramthetimer:
1. Pressthe button.
2. Press buttontomovearrowto‘SETTIMERS’.
3. Press toenterthe‘SETTIMERS’menu.
4. Press / toselectthetimeryouwishtoset.(Timer1orTimer2)
5. Press .
6. Press / tosetthehours(ontime).
7. Press tosavethehours.
8. Press / tosettheminutes(ontime).
9. Press tosavetheminutes.
10.Press / tosetthehours(offtime).
11.Press tosavethehours.
12.Press / tosettheminutes(offtime).
13.Press tosavetheminutes.
TRiwillreturntothe‘SETTIMERS’menu.
8 9
CleaRinG The TiMeRs
Toclearthetimer:
1. Pressthe button.
2. Press / buttontoscrollto‘SETTIMERS’.
3. Press toenterthe‘SETTIMERS’menu.
4. Press / toscrollto‘CLEARTIMERS’.
5. Press .
Aconfirmationmessagewillappearonthescreen.
exTeRnal TiMe CloCK
Attimes,itmaybedesirabletocontrolchlorinegenerationusinganexternaltimeswitch.IfthechlorinegeneratoristurnedON,andtheexternaltimerfailstoswitchthemainspoweroffwithin30hours,theZodiacTRiwillautomaticallystopchlorinatinginordertopreventoverchlorination.
Tosetthechlorinegeneratortorunfromanexternalclock:
1. CleartheTimerbyfollowingtheprocedureoutlinedin‘ClearingtheTimers’.
2. Pressthe buttontoturnthechlorinegeneratoron.
usinG inBuilT CloCK and TiMeRs
10 11
seTTinG The ChloRine ouTPuT
Theamountofchlorinerequiredbyyourpoolisdependentonanumberoffactorsincludingthesizeofthepool,thenumberofusersandtheclimate.
Outputwillappearasapercentageonthescreenreadout,monitorthelevelaccordingtothereadingovertimewillhelpensureoptimumoutput.
ForuserswhoupgradetotheTRi-PROmodel,chlorineoutputwillbecontrolledautomatically.
TosetChlorineOutputlevels:
1. Pressthe buttontoturnthechlorinegeneratoron.
2. Pressthe / buttonstosetthedesiredoutputlevel.
PLEASENOTE:ifusingapoolcoveryouwillneedtoreducethechlorineproductionsubstantially,pleaseuseLOWmodeifyouuseacover.SimplypressLOWbutton.
ChloRine ouTPuT levels
10 11
CoRReCT seTTinGs foR youR TRi ConTRolled Pool
fre
e
Ch
lori
ne
(p
pm
)
ph
To
tal
alk
alin
ity
(pp
m)
Cal
ciu
m
hard
ne
ss
(pp
m)
Cyan
uri
c a
cid
(p
pm
)
sal
t l
eve
l (p
pm
) s
en
sors
au
stra
lian
sta
nd
ard
1–3
7.2–7.8
80–300
90–300
30–50
4000-7000
ide
al r
ead
ing/
ran
ge
1–3
7.5
80–140
90–300
504000ppm
at27ºC**
To
in
cre
ase
*
Add
chlorine
orincrease
outputof
equipm
ent
Addbuffer
orsodaash
(sodium
carbonate)
Add
sodium
bicarbonate
Add
calcium
chloride
Add
Cyanuric
acid
AddSalt
To
de
cre
ase
*
Add
muriatic
acid
Add
muriatic
acidor
dryacid
Partially
drain
&refillpool
Partially
drain
&refillpool
Partially
drain
&refillpool
fre
qu
en
cy o
f te
stin
g (i
n p
eak
se
aso
n)
Weekly
Weekly
Weekly
Weekly
Weekly
Monthly
Quarterly
Co
RR
eC
T s
eT
Tin
Gs
fo
R y
ou
R T
Ri
Co
nT
Ro
ll
ed
Po
ol
12 13
IfyouuseanautomationorcontrollersystemtocontrolyourpoolyouwillneedtoconfigureyourTRiChlorinegeneratortoallow“communication”betweenthetwo.
you must set the controller type on the TRi before making the wiring connection.
seTTinG The ConTRolleR (To be done before making a wiring connection)
1. SwitchpowertotheTRiuniton.
2. Waitforthestart-upsequencetocomplete.
3. Pressthe button.
4. Pressthe buttontoscrolldownto‘CONTROLLER’.
5. Press toenterthecontrollermenu.
6. Press / tohighlightthecontrollerbeingused.
7. Press tosavethecontrollersetting.
8. TRiwillreturntothemainmenu.
9. Press toreturntotheoperatingscreen.
ConneCTinG To a ConTRolleR
12 13
aTTenTion Jandy ‘Rev l’ oR laTeR useRs
ItiscriticalthatthecontrollersettingbesettothecorrectZodiac,JandyorPentaircontrollerdesignation.ThereareanumberofdifferentrevisionslockedintotheTRisoftware.Pleaseseetheusermanualtodeterminethemodeland/orrevisionyouareusing.Iftheincorrectsettingisselected,damagecanbecausedtotheJandyAqualinkControlUnit.
CauTion When WiRinG To a ConTRolleR
IMPORTANT
Wiringofthecontrollershouldbecompletedbyanauthorisedpoolequipmentinstaller.
Beforeanywiringconnections/disconnectionsensuremainspowerisremovedfromboththecontrollerandtheZodiacTRiunit.
Whenconnectedtoacontroller,theTRiChlorinegeneratoractsasthe‘slave’-respondingtorequests.Thismeanstimersettingsareignoredandtheoutputsettingscannotbechanged,althoughallother‘menu’functionsarestillaccessible,exceptforLOWandBOOSTmodes.
WiRinG To a ConTRolleR
ThefollowinginstructionsshouldbereadinconjunctionwiththeinstallationguideprovidedwiththeController.
1. Removesilver‘dress’coverbypressinginatthesideswhereindicatedbelowandlift.
2. Removethetwoscrewswhichattachthelowercovertothemainunit:
ConneCTinG To a ConTRolleR
14 15
ConneCTinG To a ConTRolleR
3. RemovethelowercoverfromtheTRiunit.NOTE:IfusingeitherpHupgradeorPROunit–carefullydisconnecttheribboncablefromtheTRiunit.
4. RemovethesmallwhitebungclosesttothecentreofthelowerpaneloftheTRiunit.
5. Threadthecontrollercablethroughthehole(agrommetmaybenecessarydependingonthesizeofthecablebeingused).
6. Attachacabletietothecontrollercableasshowninthediagram.Thewiringcolourcodesareoutlinedbelow:
DependingonthemakeoftheController,makethefollowingwiringconnections:
Polaris eos / Jandy / Zodiac aqualink / aqualink TRi
Greenwire(0V)to‘0V’terminalontheTRi
Redwiretothe(+V)‘POS’terminalontheTRi
Yellow/White(B)wireto‘B’terminalonTRi
Blackwire(A)to‘A’terminalonTRi
Pentair intellitouch
GREENwireto‘B’terminalonTRi
Redwireto‘POS’terminalonTRi
Yellowwireto‘A’terminalonTRi
Blackwireto‘0V’terminalonTRi
14 15
TesTinG The WiRinG ConneCTion
OnceaconnectionhasbeenmadebetweentheControllerandtheChlorinegenerator,itwillneedtobetested.
1. TurnonthepowertotheControllerandtheZodiacTRi.
2. Ifsuccessful,a‘ ’symbolwillappearinthetoprighthandcornerofthescreenafterabout20seconds.
3. Ifthecontrollerdoesnotconnect,turnpowerofftoboththedevicesandtryagain.
veRify The WiRinG ConneCTions
Toverifytheconnection:
1. SwitchtheTRiunitonandcheckthecontrollersetting(followinstructionsunder‘SETTINGCONTROLLER’.
2. Re-testtheconnection. Note:Forsafetyreasons,theZodiacTRirevertstotheOFFsettingifthecommunication
connectionislost.
ConneCTion To ConTRolleR foR Pool/sPa CoMBinaTions
ToconnectaZodiacTRiunittoPoolorSpaValves,youwillneedtomakea“splice”intothecontrollinesfromtheController,locatedinsidethecontrolleritself.
Forfurtherinformation,consulttheinstallationmanualoftheControllerbeingused.
ConneCTinG To a ConTRolleR
16 17
Ifyourpoolhasacover,youshouldsettheoutputlevelto“low”.Thisisalsoknownas“winter”mode.
Reducingyourchlorineoutputwillhelppreventdamagetoyourpool’scoverandotherequipment.
Manual seTTinG
1. ToselectLowmodepress .
Thiswilldropthechlorineoutputtoaround10%.
2. ‘Low’willappearonthescreen. Note:LoworWintermodecannotbeselectedwhenTRiisbeing
controlledbyanexternalcontroller.
auToMaTiC seTTinG
TheZodiacTRicanbeconnectedtothevalvesofanautomaticpool/spasystem.
Whentheinputfromthevalvesissetto‘Low’theTRiwillautomaticallyrevertto‘Low’modeandtheoutputwillbelockedat10%
Detailsofthewiringconnectionareoutlinedinthe‘‘ConnectiontoAutomaticPool/SpaValve”sectionofthismanual.
for users who have upgraded to the TRi-ph or TRi-PRo, the automatic ph/aCl control function is disabled when in loW mode.
seTTinG The Mode To loW: Important If usIng a pool cover
16 17
Attimesyourpoolmayrequirealargerthannormalapplicationofchlorine.TheBoostfunctionisusedtorapidlyaddchlorine.
InBOOSTor“Superchlorinate”mode,outputsettingsaretemporarilyoverriddenandthechlorinegeneratorrunsfor24hoursat100%ChlorineProduction.
In‘TIMER’mode,thecirculationpumpwillrunfor24hours,beforeautomaticallyrevertingtopreviousoutput/timersettings.
In‘MANUAL’mode,thechlorinegeneratorwillrunat100%foracumulativetotalof24hoursbeforerevertingtothepreviousoutputsetting.
NOTE:
The‘BOOST’modecannotbeengagedunderthefollowingcurcumstances:
1) IftheTRiisinthe‘OFF’operatingmode.Thechlorinatormustbe‘ON’forBOOSTtobeengaged.
2) IfyouhaveupgradedtotheTRi-PRO
3) OrfromthefrontpanelwhentheTRiisbeingcontrolledbyanexternalcontroller.
InmostcasesaBOOSTfunctioncanbesetfromthecontrollermenu.
Consultyourthirdpartycontrollermanualformoreinformation.
seTTinG The BoosT Mode
ToactivatetheBOOSTsetting:
Pressthe button.
‘BOOST’willbedisplayedonthescreenandchlorinegenerationwillcommence.
The BoosT seTTinG
18 19
TheZodiacTRichlorinegeneratorautomaticallyprovidesanumberofinbuiltwarningsthatcanhelpidentifyproblemsandoffersolutions.
ToaccesstheHELPmenu:
1. Pressthe button.
2. Usingthe / buttons,scrolltothe‘HELP/DIAG’menu.
3. Press toenterthe‘HELP/DIAG’menu.
4. Onceinthe‘HELP/DIAG’menu,usethe / buttonstoscrollto
theerror/warningthathasbeendisplayed.
5. Press .
Anumberofsuggestedsolutionsaremomentarilydisplayed,inorderofpriority.
Afterdisplaying,theTRiautomaticallyrevertsbacktothe‘HELP/DIAG’menu.
6. Toexittothedefaultoperatingscreenwait~5seconds
ORpressthe button.
helP and TRouBleshooTinG
18 19
TokeepyourTRiUnitinthebestpossibleconditionitisrecommendedregularmaintenanceshouldbeperformed.
insPeCTinG and CleaninG The eleCTRode
InareasthatexperiencecalciumhardnesstheTRielectrodewillbenefitfromcleaning.
Tocleanyourelectrode:
1. Switchoffthefilterpumpandchlorinegenerator,closenecessaryvalvesandunplugthecellterminalcap.
2. Unscrewtheretainingringandremovetheelectrode.Ifcalciumbuildupispresent,immersetheelectrodeincellcleaningsolutionwithoutimmersingtheterminals.
3. WerecommendusingZodiacSaltChlorinatorCellCleanertocleantheelectrode.Howeveryoucanmixyourownbycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswater.Strongersolutionswillshortenterminallife.
4. Allowthecleaningsolutiontodissolvethecalciumdepositsforabout10minutes.DisposeofthecleaningsolutionatanapprovedCouncilDepotandneverintostormwaterorsewagedrains.
6. Rinsetheelectrodeincleanwaterandre-fittheelectrodeinthecellhousing.
7. Replacethecellheadandplugassemblyandresetvalvesandswitches.TurnpumpandTRion.
8. Confirmchlorineoutputandsettingsonthepowerpack.Timersettingswillbeautomaticallyretained.
MainTenanCe
20 21
eRRoRs and WaRninGs. WhaT They Mean.
no floW
Diagnosis:Insufficientwaterflowinthecell.Thiscouldmeanthecirculationpumphasceasedtofunction,orthefilterneedscleaning.Thechlorineoutputwillbeturnedoffatthistime.
CheCK salT
Diagnosis:Saltlevelisbetween3000and4000ppm,dependingonthewatertemperature.
Alwaysmaintainasaltlevelabove4000ppm.ifyoudon’tknowwhatyoursaltlevelisorhowtotestit,consultyourlocalpoolcareprofessional.
CheCK PoWeR suPPly
Diagnosis:Therecouldbeaproblemwiththepowersupply.Turnpoweroffatthepowerpointandconsultyourlocalpoolcareprofessional.
CleaninG
Diagnosis:Thecellisintheprocessofreversingpolarity.Waitapproximately5minutesandchlorineproductionshouldresumeasnormal.
20 21
TRouBleshooTinG
additional information about this product can be found at zodiac.com.au
Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.
Your Local Dealer:
22 23
express Warranty*ZodiacGroupAustralia Pty Ltd (Zodiac australia)warrants that theZodiacTRiSaltwaterChlorineGeneratorwillbefreefromdefectsinmaterialsandworkmanshipfortheperiodof3yearsfromthedateofpurchase.
* The warranty applicable to commercial application is limited to 12 months from the date of installation.
Conditions
1 Thisexpresswarrantyonly applies if theProducthasbeenpurchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).
PurchasefromanAuthorisedDealerensuresthattheproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,and that thePurchaserhasaccess toappropriate technicalknowledgeandadvice.
2 ZodiacAustralia’s liabilityunder thisexpresswarranty is limited, at itsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.
3 Thisexpresswarrantydoesnotapplyinthefollowingcircumstances:
(a)if the Product has not been installed in accordancewithZodiac’sinstallationinstructions;
(b)iftheProducthasbeenmodifiedotherthanasauthorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;
(c)if a defect results fromuse of the Product outside recommendedoperatingconditions;or
(d)if a defect results from damage (including damage to any internalelectronics)causedbyapowersurgeorlightningstrike.
Zodiac chlorinators are designed and tested in accordance withInternational Standard EN 61000-6-1 immunitymeasurements. Theyaredesignedtotolerateminorfluctuations(2000volts)inpowersupplythatcanbereasonablyexpectedtooccurintheenergygrid.Theywillnottoleratepowersurgesoutsidetheselimitsnorwilltheywithstandlightningstrikes.
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
22 23
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithintheseparameters,ZodiacAustraliawillnotberesponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.
5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobefreefromdefectsinmaterialsandworkmanshipfortheremainderofthewarrantyperiodorfor12monthsfromthesupplyofthereplacement,whicheverislonger.
6 WarrantyclaimsrelatingtoreplacementoftheelectrodesforLMseries,Cseries,DuoClearandDserieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionofthewarrantyperiod duringwhich theoriginal electrode functioned effectively. Thewarrantyperiodforthereplacementelectrodeistheremainderofthewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.ThePurchasermustpayfullcostforanyreplacementelectrodesafterthefirstreplacement.
Product warranty registration
7 PurchasersshouldregistertheirProductsassoonasconvenientlypossibleafterpurchasebycompletingaProductWarrantyRegistrationFormandpostingittoZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.
8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.
24 25
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
how to make a warranty claim
9 ThePurchasermusttelephoneoremailZodiacAustraliaCustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.
Contactdetailsare:
Zodiac Group australia Pty ltd 219WoodparkRoadSmithfieldNSW2164
Customer service Telephone:1800688552Emailaddress:aftersales@zodiac.com
10ZodiacAustralia reserves the right to determine, in relation to eachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerat theaddresswhere thePurchaserpurchased theProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshoporatthepremisesofanauthorizedZodiacwarrantyagent.
11 IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawillreimbursethePurchaserforchargesreasonablyincurreduponproofofthecharges.
24 25
ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees
additional guarantees, rights and remediesaustralian Purchasers - Guarantees under the australian Consumer law
12Thebenefitsofthisexpresswarrantyareinadditiontootherguarantees,rights and remediesAustralian consumers have under theAustralianConsumerLaw.
13ZodiacAustraliaproductscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.
Purchasers in other Countries
14ThelawsandregulationsofothercountriesmayconferonPurchasersinthosecountriesadditionalrightsandremedies.Totheextentthattheycannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthatitispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoastobeconsistentwithZodiacAustralia’sexpresswarranty.
inConsisTenCy WiTh WaRRanTy sTaTeMenTs in PRoduCT Manuals oR oTheR doCuMenTs aCCoMPanyinG PRoduCTs
Ifanywarrantystatements inaZodiacAustraliaproductmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.
ZodiacisaregisteredtrademarkofZodiacGroupAustraliaPtyLtdABN87002641965
ZodiaC CusToMeR seRviCe CenTRe
ZodiacGroupAustralia:
219WoodparkRd,Smithfield,NSW2164Australia
Tel:1800688552Fax:1300781688
Email:aftersales@zodiac.com.auwww.zodiac.com.au
Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.
Improperusecouldaffectperformanceandvoidwarranty.
©CopyrightZodiacAustraliaLtd2013
W176781REV.A