Post on 15-Sep-2019
transcript
ACCESSORY CATALOGUE UK and IrelandIssue 3
www.trylon.com
ABOUT US
Anixter is a leading global supplier of communications and security products and electrical and electronic wire and cable. We help our customers specify solutions and make informed purchasing decisions around technology, applications and relevant standards. Throughout the world, we provide innovative supply chain management solutions to reduce our customers’ total cost of production and implementation.
“ Anixter’s value to customers can be summed up in the depth and breadth of our inventory, application-specific technical and product knowledge, and a wide array of inventive Supply Chain Solutions mapped to our customers’ specific requirements.”
Bob Eck, President & CEO
ANIXTER IS A PROUD DISTRIBUTOR OF TRYLON PRODUCTS.
UNITED KINGDOM AND IRELAND
INDUSTRIALAberdeen Oil and Gas Tel: +44 (0)1224 275680
Birmingham Construction Tel: +44 (0)121 322 7140
Dublin Construction Tel: +353 1 257 2000
Glasgow Construction Tel: +44 (0)1698 503810
Uxbridge Construction Tel: +44 (0)845 604 1301
Warrington Construction Tel: +44 (0)1925 810121
Warrington Rail Tel: +44 (0)870 242 2822
anixter.co.uk
anixter.ie
OEMBarrow-in-Furness Tel: +44 (0)1229 825871
Chesterfield Tel: +44 (0)1246 451600
Coventry Tel: +44 (0)24 7646 5829
Diss Tel: +44 (0)1379 643506
Glasgow Tel: +44 (0)141 445 2193
Leeds Tel: +44 (0)113 244 0321
Liverpool Tel: +44 (0)151 355 2211
Luton Tel: +44 (0)1582 498900
Newcastle Tel: +44 (0)191 482 7660
Plymouth Tel: +44 (0)1752 341100
Portsmouth Tel: +44 (0)23 9286 5469
Sheffield Tel: +44 (0)1142 709300
Warrington Marine and Defence Tel: +44 (0)1925 816166
anixter.co.uk
FOR FURTHER INFORMATION CONTACT YOUR LOCAL ANIXTER REPRESENTATIVE.
PHONE, FAX, EMAIL WITH SALES REP
B2B INTEGRATION (E.G., EDI, JIT, ERP SYSTEMS)
EPROCUREMENTPUNCHOUT CATALOG(E.G., ARIBA, SCIQUEST)
CUSTOM CATALOG(E.G., INTELLIBID, ACCUBID)
ANIXTER.COM(RETAIL PRICING)
EANIXTER.COM(CONTRACT PRICING)
CUSTOMER BRANDED E-COMMERCE WEBSITE(CONTRACT PRICING)
PHYSICAL STORES ELECTRONIC INVOICES AND PAYMENTSCONSOLIDATED INVOICESTATEMENTS Major enhancements coming soon.
AUTOMATED ORDER CONFIRMATION AND SHIPMENT NOTIFICATION
eAnixter.com
DIFFERENT WAYS TO BUY FROM ANIXTER
GLOBAL REACH. LOCAL ADVANTAGE.With Anixter, you get a true local partner around the world. No other distributor of our kind can claim an in-country presence in more than 50 countries and 300 cities.
We do business in more than 35 currencies and 30 languages, which means we are uniquely positioned to help facilitate your project in the local environment, reduce risks and keep costs down.
CORPORATE SNAPSHOT
500,000PRODUCTS
OVER
50COUNTRIES
APPROXIMATELY
$$1.1 BILLIONINVENTORY
IN
300CITIES
STOCK SYMBOL
AXEFORTUNE
500 LIST
NUMBER OFEMPLOYEES
APPROXIMATELY 9,100
YEAR FOUNDED
1957APPROXIMATELY
100,000CUSTOMERS
270WAREHOUSES/
BRANCHES
Anixter Inc. World Headquarters2301 Patriot BoulevardGlenview, Illinois 60026224.521.8000
Wire & Cable EMEA HeadquartersUnit A, The BeaconsBirchwood ParkBirchwood, WarringtonCheshire, WA3 6GP+44 (0) 1925 838658
info@trylon.com www.trylon.com 4
CE Product Cer fi ca on Example ....................6
Mount Calcula on Example ............................7
Antenna/MW Standoff Mounts ......................8
Apex Standoff Mount .....................................9
Yoke Bracket Mount .....................................10
Light Duty Wall Mount Assembly ..................11
Wall Mount Assembly ..................................12
Corner Mount Assembly ...............................13
Pipe Extension Assembly ..............................14
3-Pipe 3-Sector Spine Mount ........................15
6-Pipe 3-Sector Spine Mount ........................16
Pole Ring Standoff ........................................17
2-Level Pole Ring Standoff ............................18
2L 6P Pole Ring Standoff ...............................19
Bulk Pipe ......................................................20
Light Duty Roo op Ballast Mount .................21
Single Pipe Roof Ballast Mount .....................22
Double Pipe Roof Ballast Mount ...................23
4-Hole Feeder Bracket ..................................25
6-Hole Feeder Bracket ..................................26
Gantry Poles .................................................27
Fixed Crossover Assembly .............................28
Universal Fixed Crossover Assembly .............29
2-Way RRU Mount ........................................30
3-Way RRU Mount ........................................31
4-Way RRU Mount ........................................32
Installa on Drawings ....................................33Antenna/MW Standoff Mount (4.927.0108.001) .....................33Apex Standoff Mount (4.927.0150.001) ...................................36Yoke Bracket Mount (4.927.0102.001) .....................................37Yoke Bracket Mount Without Pipe (4.927.0102.101) ...............38Light Wall Mount (4.954.0012.001) ..........................................39Wall Mount (4.954.0010.001) ..................................................40Corner Mount (4.954.0011.001) ..............................................41Pipe Extension Assembly (4.927.0100.001) .............................423-Pipe 3-Sector Spine Mount (4.927.0104.001) .......................433-Pipe 3-Sector Spine Mount Without Pipe (4.927.0104.101) .446-Pipe 3-Sector Spine Mount (4.927.0105.001) .......................456-Pipe 3-Sector Spine Mount Without Pipe (4.927.0105.101) .46Pole Ring Standoff (4.927.0101.001) ........................................47Pole Ring Standoff Without Pipe (4.927.0101.101) ..................482-Level Pole Ring Standoff (4.927.0106.001)............................492L 6P Pole Ring Standoff (4.927.0107.001) ..............................50Light Duty Roof Ballast Mount (4.951.0012.001) .....................51Single Pipe Roof Ballast Mount (4.951.0010.001) ....................52Double Pipe Roof Ballast Mount (4.951.0011.001) ..................534-Hole Feeder Bracket (4.939.0090.001) ..................................546-Hole Feeder Bracket (4.939.0091.001) ..................................55Gantry poles (5.939.1500.003) .................................................56Fixed Cross Over Assemblies (4.960.0001.001) ........................57Universal Fixed Cross Over Assemblies (4.960.0007.001) ........592-Way RRU Mount (4.927.0110.001) .......................................603-Way RRU Mount (4.927.0111.001) .......................................614-Way RRU Mount (4.927.0109.001) .......................................62
Trylon Also Off ers .........................................64
TABLE OF CONTENTS
Table of Contents
Note: Full details of our products are available upon request. Please contact EMEA Director Adam Allan, adam.allan@trylontsf.com, for further information. Additional requests can also be sent to info@trylon.com
info@trylon.com www.trylon.com 5
CE PRODUCT CERTIFICATION
EXAMPLE
Identification No. 1381 of Notified Body Trylon TSF
21 South Field Drive Elmira, Ontario
Canada N2B 0A6
14 Kit Part #4.927.0103.001
Essential Characteristics Declared Performance Harmonized Technical Specification
Tolerances on dimensions and shape
In accordance with EN 1090-2 EN 1090-1:2009
Weldability Based in S355JR Material, Max CEV % is 0.543
Fracture toughness / brittle strength
As per EN 10025:2004 requirements for S275JR & S355JR steel - 27 J at 20° C
Impact resistance See Above.
Load bearing capacity As per EN-1993-3-1 (2007), Minimum capacity is 4.2kN
Deformation at serviceability limit state
As per EN-1993-3-1 (2007), Maximum deflection is 0.6mm
Fatigue strength NPD
Resistance to fire As per EN-13501-1, REI 180
Reaction to fire As per EN-13501-2, A1
Release of Cadmium and its compounds
NPD
Emission of Radioactivity NPD
Durability All products Galvanized to European EN ISO 1461
info@trylon.com www.trylon.com 6
CE PRODUCT CERTIFICATION
EXAMPLE
Declaration of Performance (according to REGULATION (EU) No 305/2011)
Kit Description: MW Standoff Mount (1m Pipe) Kit Part Number: 4.927.0103.001 DoP Number: 4.927.0103.001 Applicable Harmonized Standard: EN 1090-1:2009 Intended Usage: Antenna Support Mount Manufacturer Information: Trylon TSF 21 South Field Drive Elmira, Ontario Canada N2B 0A6 Tel: (519) 669 – 5421 Website: www.Trylon.com CE Marking Notified Body: SGS Italia S.p.A. Via G. Gozzi 1/a Milan, 20129 Italy Tel: +39 02 73 931 Website: www.sgsgroup.it/
System of assessment and verification of constancy of performance of the product: EXC2 Notified factory production control certification body No. 1381 performed the initial inspection of the manufacturing plant and of factory production control and the continuous surveillance, assessment, and evaluation of factory production control and issued the certificate of conformity of the factory production control Stephanie Berry Date: June 29, 2015 Director of Product Operations Trylon
info@trylon.com www.trylon.com 7
MOUNT CALCULATION
EXAMPLE
Antenna/MW Standoff Mount (0.5m Pipe)
With Medium Backings Kit # 4.927.0108.001
21 South Field Drive, PO Box 186 Design Code: BS8100
Elmira, Ontario, Canada N3B 2Z6
519-669-5421 (ph), 519-669-8912 (fx)
INPUT VALUES
1) SITE AND TOWER PARAMETERS
Wind Speed* 24.0 m/s
Tower Height 60.0 m
Antenna Elevation* 60.0 m
Site Altitude 100 m
2) ANTENNA
Antenna Type* r (Flat,Round)
Height of Antenna* 1.50 m
Width of Antenna* 0.50 m
Weight of Antenna* 50.0 kg
3) MOUNT OPTIONS
Number of Mounting Angles* 1 (1 or 2)
OK!
Length of Horizontal Pipe* 0.5 m (0.5, 1, 2 or 3)
Backing* Medium (Medium, Small)
4) MAX ALLOWABLE ANTENNA DEFLECTION
Relative to tower/wall* 5.00 mm
SUMMARY of RESULTSDESIGNED TO: 24M/S WIND SPEED
(1) 1.5M x0.5M ANTENNAResults Capacity
Vertical Pipe Bend Check 500mm LONG x 76mm OD x 6mm THK [345MPa] 21.71 MPa 310.28 MPaPASS [1.7%]
Horizontal Angle Bend Check 64mm x 64mm x 6mm, 613mm LONG [300MPa] 228.79 MPa 273.04 MPaPASS [83.8%]
Backing Channel Bend Check 260mm LONG x 44mm WIDE x 57mm DEEP x 5mm THK [300MPa] 111.15 MPa 273.04 MPaPASS [40.7%]
Backing Rod Combined Shear & Tension CheckPASS [8.2%]
Tower Leg Reactions Per Backing Horizontal 1.35 kNVertical 0.63 kN
Torsional Moment 0.52 kN.mTotal mount Deflection 0.55 mm PASS
APPROX. MOUNT WEIGHT: 0.60 kN (Antenna and tower connection included)
Assumptions: - Areas calculated usings BS8100 guidelines - Quality Class: A - Design based on 50 year return basic wind speed - Terrain Category: III (Typ UK farmland) - Environment Conditions: Adjacent to Main Road - Checked Design for Member Stresses - Usage: Broadcasting - S values are calculated using std tables/formulas - Antenna centrally located on vertical Pipe - Atmospheric environment assumed to by Type (a) as per BS8100, cl. 3.1.1
ELEVATION VIEW
PLAN VIEW
info@trylon.com www.trylon.com 8
ANTENNA/MW STANDOFF
MOUNTS
NOTES: 1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Mount assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 33, 34, and 35 for Installation Drawings
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Length of Pipe (0.5m) - Round / Flat
Allowable Antenna Loading
1.41 m2 1.23 m2 1.08 m2 1.26 m2 1.10 m2 0.96 m2
0.61 m2 0.52 m2 0.44 m2 0.54 m2 0.45 m2 0.39 m2
Length of Pipe (1m) - Round / Flat
3.95 m2 2.45 m2 2.15 m2 2.52 m2 2.19 m2 1.92 m2
1.24 m2 1.05 m2 0.89 m2 1.08 m2 0.91 m2 0.78 m2
Length of Pipe (2m) - Round / Flat
2.74 m2 2.39 m2 2.10 m2 2.46 m2 2.14 m2 1.87 m2
1.20 m2 1.02 m2 0.87 m2 1.05 m2 0.89 m2 0.76 m2
Length of Pipe (3m) - Round / Flat
2.67 m2 2.33 m2 2.05 m2 2.40 m2 2.08 m2 1.82 m2
1.17 m2 0.99 m2 0.85 m2 1.02 m2 0.86 m2 0.74 m2
Kit # Description Qty Weight (kg) 4.927.0108.001 MW Standoff Mount (76mm OD x 0.5m Pipe) Each 13.2 kg
4.927.0103.001 MW Standoff Mount (76mm OD x 1m Pipe) Each 24.5 kg
4.927.0103.002 MW Standoff Mount (76mm OD x 2m Pipe) Each 36.0 kg
4.927.0103.003 MW Standoff Mount (76mm OD x 3m Pipe) Each 47.7 kg
4.927.0103.101 MW Standoff Mount (Without Pipe) Each 14.7 kg
info@trylon.com www.trylon.com 9
Kit # Description Qty Weight (kg) 4.927.0150.001 Apex Standoff Mount (Without Pipe & U-Bolts) Each 31.8 kg
APEX STANDOFF MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
5.43 m2 4.50 m2 3.80 m2 4.77 m2 3.96 m2 3.33 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 36 for Installation Drawing
info@trylon.com www.trylon.com 10
YOKE BRACKET MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
3.93 m2 3.25 m2 2.73 m2 3.38 m2 2.79 m2 2.34 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 37 and 38 for Installation Drawings
Kit # Description Qty Weight (kg)
4.927.0102.001 2-Pipe Yoke Bracket Mount (60mm OD x 3m Pipe) Each 77.0 kg
4.927.0102.101 2-Pipe Yoke Bracket Mount (Without Pipe) Each 44.9 kg
info@trylon.com www.trylon.com 11
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
2.93 m2 2.93 m2 2.93 m2 2.93 m2 2.93 m2 2.93 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 39 for Installation Drawing
LIGHT DUTY WALL MOUNT
ASSEMBLY
Kit # Description Qty Weight (kg)
4.954.0012.001 Solid Light Wall Mount Assembly (60mm OD x 1m Pipe) Each 13.7 kg
4.954.0012.002 Brick Light Wall Mount Assembly (60mm OD x 1m Pipe) Each 11.7 kg
info@trylon.com www.trylon.com 12
WALL MOUNT ASSEMBLY
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
16.75 m2 13.88 m2 11.69 m2 14.47 m2 11.96 m2 10.05 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 40 for Installation Drawing
Kit # Description Qty Weight (kg)
4.954.0010.001 Solid Wall Mount Assembly (76mm OD x 2m Pipe) Each 60.0 kg
4.954.0010.002 Brick Wall Mount Assembly (76mm OD x 2m Pipe) Each 54.0 kg
info@trylon.com www.trylon.com 13
CORNER MOUNT ASSEMBLY
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
4.87 m2 4.27 m2 3.75 m2 4.38 m2 3.81 m2 3.34 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top wall.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 41 for Installation Drawing
Kit # Description Qty Weight (kg)
4.954.0011.001 Solid Wall Corner Mount Assembly (76mm OD x 2m Pipe) Each 37.0 kg
4.954.0011.002 Brick Wall Corner Mount Assembly (76mm OD x 2m Pipe) Each 35.0 kg
info@trylon.com www.trylon.com 14
PIPE EXTENSION ASSEMBLY
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Mount assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) Assumed 0.2m Clamp Distance and 2m Extension Pipe.6) See page 42 for Installation Drawing
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
4.71 m2 3.90 m2 3.27 m2 4.04 m2 3.34 m2 2.81 m2
Kit # Description Qty Weight (kg)
4.927.0100.001 Pipe Extension Assembly Each 6.0 kg
info@trylon.com www.trylon.com 15
3-PIPE 3-SECTOR SPINE
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
2.29 m2 2.29 m2 2.29 m2 2.29 m2 2.29 m2 2.29 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 43 and 44 for Installation Drawings
Kit # Description Qty Weight (kg)
4.927.0104.001 3-Pipe, 3-Sector Spine Mount (76mm OD x 2m Pipe) Each 156.0 kg
4.927.0104.101 3-Pipe, 3-Sector Spine Mount (Without Pipe) Each 88.4 kg
info@trylon.com www.trylon.com 16
6-PIPE 3-SECTOR SPINE
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading
1.11 m2 1.11 m2 1.11 m2 1.11 m2 1.11 m2 1.11 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 25.0 kg antenna weight per square meter of antenna area.5) See pages 45 and 46 for Installation Drawings
Kit # Description Qty Weight (kg)
4.927.0105.001 6-Pipe, 3-Sector Spine Mount (60mm OD x 1.5m Pipe) Each 223.0 kg
4.927.0105.101 6-Pipe, 3-Sector Spine Mount (Without Pipe) Each 179.0 kg
info@trylon.com www.trylon.com 17
POLE RING STANDOFF
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
5.80 m2 5.28 m2 4.84 m2 5.38 m2 4.89 m2 4.48 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See pages 47 and 48 for Installation Drawings
Kit # Description Qty Weight (kg)
4.927.0101.001 Pole Ring Standoff (76mm OD x 2m Pipe) Each 158.0 kg
4.927.0101.101 Pole Ring Standoff (Without Pipe) Each 88.4 kg
info@trylon.com www.trylon.com 18
2-LEVEL POLE RING
STANDOFF
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
8.43 m2 6.97 m2 5.85 m2 7.23 m2 5.98 m2 5.02 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 49 for Installation Drawing
Kit # Description Qty Weight (kg)
4.927.0106.001 2-Level Pole Ring Standoff (76mm OD x 4m Pipe) Each 316.0 kg
info@trylon.com www.trylon.com 19
2L 6P POLE RING STANDOFF
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810030m MOUNT AGL 60m MOUNT AGL
Wind Speed 20 m/s 22 m/s 24 m/s 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading per Pipe
9.22 m2 7.62 m2 6.40 m2 7.91 m2 6.54 m2 5.49 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 50 for Installation Drawing
Kit # Description Qty Weight (kg)
4.927.0107.001 2L 6P Pole Ring Standoff (60mm OD x 3.5m Pipe) Each 397.0 kg
info@trylon.com www.trylon.com 20
BULK PIPE
Kit # Description Qty Weight (kg) 5.960.0191.001 60mm OD CHS Pipe x 4mm thk x 0.5m long Each 2.8 kg
5.960.0191.002 60mm OD CHS Pipe x 4mm thk x 1m long Each 5.7 kg
5.960.0191.005 60mm OD CHS Pipe x 4mm thk x 1.5m long Each 8.6 kg
5.960.0191.003 60mm OD CHS Pipe x 4mm thk x 2m long Each 11.4 kg
5.960.0191.007 60mm OD CHS Pipe x 4mm thk x 2.5m long Each 14.3 kg
5.960.0191.004 60mm OD CHS Pipe x 4mm thk x 3m long Each 17.1 kg
5.960.0191.006 60mm OD CHS Pipe x 4mm thk x 3.5m long Each 20.0 kg
5.960.0190.005 76mm OD CHS Pipe x 6mm thk x 0.5m long Each 5.8 kg
5.960.0190.001 76mm OD CHS Pipe x 6mm thk x 1m long Each 11.4 kg
5.960.0190.002 76mm OD CHS Pipe x 6mm thk x 2m long Each 23.0 kg
5.960.0190.006 76mm OD CHS Pipe x 6mm thk x 2.5m long Each 28.8 kg
5.960.0190.003 76mm OD CHS Pipe x 6mm thk x 3m long Each 34.4 kg
5.960.0190.004 76mm OD CHS Pipe x 6mm thk x 4m long Each 46.0 kg
5.960.0193.001 88.9mm OD CHS Pipe x 5mm thk x 0.5m long Each 5.9 kg
5.960.0193.002 88.9mm OD CHS Pipe x 5mm thk x 1m long Each 11.9 kg
5.960.0193.003 88.9mm OD CHS Pipe x 5mm thk x 1.5m long Each 17.7 kg
5.960.0193.004 88.9mm OD CHS Pipe x 5mm thk x 2m long Each 23.6 kg
5.960.0193.005 88.9mm OD CHS Pipe x 5mm thk x 2.5m long Each 29.6 kg
5.960.0193.006 88.9mm OD CHS Pipe x 5mm thk x 3m long Each 35.5 kg
5.960.0193.007 88.9mm OD CHS Pipe x 5mm thk x 3.5m long Each 41.5 kg
5.960.0193.008 88.9mm OD CHS Pipe x 5mm thk x 4m long Each 47.2 kg
info@trylon.com www.trylon.com 21
LIGHT DUTY ROOFTOP BALLAST
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020m Roof Height AGL
Wind Speed 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading 0.48 m2 0.35 m2 0.26 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 51 for Installation Drawing
Kit # Description Qty Weight (kg)
4.951.0012.001 Light Duty Roof Ballast Mount Each 45.5 kg
info@trylon.com www.trylon.com 22
SINGLE PIPE ROOF BALLAST
MOUNT
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020 m Roof Height AGL
Wind Speed 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading 2.61 m2 2.13 m2 1.76 m2
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 52 for Installation Drawing
Kit # Description Qty Weight (kg)
4.951.0010.001 Single Pipe Roof Ballast Mount Each 205.0 kg
info@trylon.com www.trylon.com 23
DOUBLE PIPE ROOF BALLAST
MOUNT
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antennas assumed at 3.0m ARL.3) Terrain Category V; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 53 for Installation Drawing
MAXIMUM ALLOWABLE ROUND ANTENNA AREA - PER BS810020m Roof Height AGL
Wind Speed 20 m/s 22 m/s 24 m/s
Allowable Antenna Loading 4.12 m2 3.39 m2 2.82 m2
Kit # Description Qty Weight (kg)
4.951.0011.001 Double Pipe Roof Ballast Mount Each 297.0 kg
info@trylon.com www.trylon.com 24
• Rhino Tile is fi xed together using interlocking mechanism, no need for taping together
• Can be used inside or outside for temporary or semi-permanent applications
• Edging strip can be purchased separately and provide non-trip access where needed. Edging strip come in male or female formats
• Easy to cut to size with jigsaw or stanley knife
Guidelines for Use
Rhino Tile InformationMaterial PVC Tile
Size 500mm x 500mm 14 mmWeight 1.7kg per tileColor Black (Recycled) from stock
Fire & Heat Resistance UL 94 V-2Slip Resistance BS EN 7188
Recyclability 100% recycled and recyclableAnixter Electrical and Electronic Solutions Part Numbers
SMMATM5000M5000000 Black Rhino Tile PVC-FRSMTILEM5000003 Yellow Rhino edging strip (male) SMTILEM5000004 Yellow Rhino edging strip (female)
Why Choose Rhino Tile• Interlocking mechanism, no need for tape• Extremely durable, absorbing impact and
shock• Perfect for heavy foot traffi c• Easy to cut if required• 100% Recycled• Easy to clean & can be used over and over
again
OPTIONAL ROOFMOUNT
ACCESSORY
info@trylon.com www.trylon.com 25
4-HOLE FEEDER BRACKET
NOTES:1) See page 54 for Installation Drawing
Kit # Description Qty Weight (kg)
4.939.0090.001 4-Hole Feeder Bracket Each 3.0 kg
info@trylon.com www.trylon.com 26
6-HOLE FEEDER BRACKET
NOTES:1) See page 55 for Installation Drawing
Kit # Description Qty Weight (kg)
4.939.0091.001 6-Hole Feeder Bracket Each 3.4 kg
info@trylon.com www.trylon.com 27
GANTRY POLES
NOTES:.1) See page 56 for Installation Drawing
Kit # Description Qty Weight (kg)
5.939.1500.003 114 OD x 6 length 1.5m Each 69.1 kg
5.939.1500.004 114 OD x 6 length 3.0m Each 132.9 kg
info@trylon.com www.trylon.com 28
FIXED CROSSOVER ASSEMBLY
NOTES:1) See pages 57 and 58 for Installation Drawing
Kit # Description Qty Weight (kg)
4.960.0001.001 Fixed Crossover Assembly (60mm to 60mm) Each 4.7 kg
4.960.0002.001 Fixed Crossover Assembly (89mm to 89mm) Each 6.0 kg
4.960.0003.001 Fixed Crossover Assembly (89mm to 76mm) Each 6.0 kg
4.960.0004.001 Fixed Crossover Assembly (60mm to 89mm) Each 6.0 kg
4.960.0005.001 Fixed Crossover Assembly (76mm to 76mm) Each 6.0 kg
4.960.0006.001 Fixed Crossover Assembly (60mm to 76mm) Each 6.0 kg
info@trylon.com www.trylon.com 29
UNIVERSAL FIXED CROSSOVER
ASSEMBLY
NOTES:1) Assumed 100m Site Altitude. Assume 20% less allowable antenna area per 100m increase in Site Altitude.2) Antenna assumed at top tower.3) Terrain Category III; Partial Wind Safety Factor 1.2; Design Strength Factor 1.14) Assumed 50.0 kg antenna weight per square meter of antenna area.5) See page 59 for Installation Drawing
Kit # Description Qty Weight (kg)
4.960.0007.001 Universal Fixed Crossover Assembly Each 10.9 kg
info@trylon.com www.trylon.com 30
2-WAY RRU MOUNT
Kit # Description Qty Wt
4.927.0110.001 2-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Each 13.5 kg
NOTES:1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models 2) See page 60 for Installation Drawing
info@trylon.com www.trylon.com 31
3-WAY RRU MOUNT
Kit # Description Qty Wt
4.927.0111.001 3-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Ea 18.6 kg
NOTES: 1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models2) See page 61 for Installation Drawing
info@trylon.com www.trylon.com 32
4-WAY RRU MOUNT
Kit # Description Qty Wt
4.927.0109.001 4-way RRU Mount Kit (6.0 cm OD to 11.5 cm OD, 7.6 cm to 10.1 cm angle) Ea 23.5 kg
NOTES:1) Can be used on Ericsson RRU Models, RRU S11, RRU S01, RRUL, RRUA2. Please inquire for all other RRU Models 2) See page 62 for Installation Drawing
info@trylon.com www.trylon.com 33
ANTENNA/MW STANDOFF MOUNT
INSTALLATION
info@trylon.com www.trylon.com 34
ANTENNA/MW STANDOFF MOUNT
INSTALLATION
info@trylon.com www.trylon.com 35
ANTENNA/MW STANDOFF MOUNT WITHOUT PIPE
INSTALLATION
info@trylon.com www.trylon.com 36
APEX STANDOFF MOUNT
INSTALLATION
info@trylon.com www.trylon.com 37
YOKE BRACKET MOUNT
INSTALLATION
info@trylon.com www.trylon.com 38
YOKE BRACKET MOUNT WITHOUT PIPE
INSTALLATION
info@trylon.com www.trylon.com 39
LIGHT WALL MOUNT
INSTALLATION
info@trylon.com www.trylon.com 40
WALL MOUNT INSTALLATION
info@trylon.com www.trylon.com 41
CORNER MOUNT INSTALLATION
info@trylon.com www.trylon.com 42
PIPE EXTENSION ASSEMBLY
INSTALLATION
info@trylon.com www.trylon.com 43
3-PIPE 3-SECTOR SPINE MOUNT
INSTALLATION
info@trylon.com www.trylon.com 44
3-PIPE 3-SECTOR SPINE MOUNT WITHOUT PIPE
INSTALLATION
info@trylon.com www.trylon.com 45
6-PIPE 3-SECTOR SPINE MOUNT
INSTALLATION
info@trylon.com www.trylon.com 46
6-PIPE 3-SECTOR SPINE MOUNT WITHOUT PIPE
INSTALLATION
info@trylon.com www.trylon.com 47
POLE RING STANDOFF
INSTALLATION
info@trylon.com www.trylon.com 48
POLE RING STANDOFF WITHOUT PIPE
INSTALLATION
info@trylon.com www.trylon.com 49
2-LEVEL POLE RING STANDOFF
INSTALLATION
info@trylon.com www.trylon.com 50
2L 6P POLE RING STANDOFF
INSTALLATION
info@trylon.com www.trylon.com 51
LIGHT DUTY ROOF BALLAST MOUNT
INSTALLATION
info@trylon.com www.trylon.com 52
SINGLE PIPE ROOF BALLAST MOUNT
INSTALLATION
info@trylon.com www.trylon.com 53
DOUBLE PIPE ROOF BALLAST MOUNT
INSTALLATION
info@trylon.com www.trylon.com 54
4-HOLE FEEDER BRACKET INSTALLATION
info@trylon.com www.trylon.com 55
6-HOLE FEEDER BRACKET INSTALLATION
info@trylon.com www.trylon.com 56
GANTRY POLES INSTALLATION
info@trylon.com www.trylon.com 57
FIXED CROSS OVER ASSEMBLIES INSTALLATION
info@trylon.com www.trylon.com 58
FIXED CROSS OVER ASSEMBLIES INSTALLATION
info@trylon.com www.trylon.com 59
UNIVERSAL FIXED CROSS OVER ASSEMBLIES
INSTALLATION
info@trylon.com www.trylon.com 60
2-WAY RRU MOUNT
INSTALLATION
info@trylon.com www.trylon.com 61
3-WAY RRU MOUNT
INSTALLATION
info@trylon.com www.trylon.com 62
4-WAY RRU MOUNT
INSTALLATION
info@trylon.com www.trylon.com 63
NOTES
info@trylon.com www.trylon.com 64
TRYLON ALSO OFFERS
SuperTitan KD Specifi ca ons• Brand New Packaging Process
• Minimize freight costs (weight & dimensions)• Minimizes storage space• Improved economic footprint
• All members are hot-dip galvanized throughout• Designed to conform with CE standard• Maximum height: 57.9 meters• Sec on height: 3.0 meters
The SuperTitan KD is a modular tower that can be built up to 57.9 meters high. Consis ng of 21 standard sec ons, each 3.0 meters high, this modular system can be confi gured to create towers of varying heights and loading capaci es.
SuperTitan MAX Specifi ca ons
• Tallest stock product tower off ered• Ships from Trylon• Designed to conform with CE Standards• Maximum height: 76.5 meters• Sec on height: 5.8 meters
Designed using the same basic modular confi gura on as the SuperTitanKD model, the SuperTitan MAX features a wide range of heights and op ons for increasing strength and capacity. The SuperTitan MAX is shipped in 5.8 meters sec ons which can be assembled to a maximum height of 76.5 meters, making it Trylon’s tallest self-suppor ng stocked tower.
www.trylon.com
TM, ®, ©, LOGOS, STYLIZED NAMES ARE TRADEMARKS OF TRYLON MANUFACTURING COMPANY LTD. © 2017 PRINTED IN CANADA
For further informa on please call your local Anixter Electrical and
Electronic Solu ons representa ve. Contact informa on can be found
on page 2 of this brochure.