B163 main requirements
• To be recuperated 163 cold box
Fresca
7 Cryostats including their distribution line and 1.9 K pumping system
• New infrastructure 163 combined valve box
Related cryogenic lines• Combined line for Fresca, Fresca 2, Cryostats
• Lines to cold box
• 1.9 K pumping line including heater
• 163/165 transfer line
New 1.9 K pumping unit, 2.3 g/s @ 10 mbar
GHe panel for Fresca 2 and Fresca including He guards
12 000 l LHe Dewar instead the existing 6 000 l LHeDewar if approved
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 3
B. 163 current state
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 4
B. 163, elements to be recuperated MEYLSQLH0002
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 5
7 cryostats including the cryogenic
line and 1.9 K pumping system
Fresca
Cold box
B165 main requirements
• To be recuperated 165 cold box
165 Filling station
• New infrastructure 20 000 l LHe Dewar replacing the existing 5 000 l LHe
Dewar
165 combined valve box
Related cryogenic lines• From 165 CB to 165 combine valve box
• From 165 combined valve box to the Filling station
• From 165 combined valve box to Trailer Dewar
• 163/165 transfer line
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 6
B. 165, elements to be replaced
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 7
Common 165 & 163, LN distribution
• Valve box
• Related cryogenic lines
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 8
Preliminary simplified flow scheme
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 9
163 Dewar6 000 l
165 Dewar 20 000 l
CB 163 CB 165
Trailer Dewar
Fresca Fresca 2
Filling station
7x small cryostats
LPGazo
Gazo LP Gazo
Gazo LP Gazo
Gazo
Valve box 163
Valve box 165
He gas panel F
He gas panel F2
B. 163
B. 165
Cryogenic valves
Warm valves
LP
B. 163
B. 165
163 Combine valve box
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 10
Combined line: Fresca + Fresca 2
Gazo/LPGazo/LP
Gazo/LP
CB 163
HP GHe
To 7 cryostats
To 165 Dewar
LHe in
LHe out
LHe in
Cold GHe out
Fresca 2 Fresca1.9 K
pumping line
163 LHe Dewar
163 valve box
1 2 3 4 5 6 7 8 9 11 12 13 14 15 16
Fresca 2
1-GHe return, external2-GHe return, internal3-LN in, shield4-CD/WU, external down5-LHe in, external up6-LHe in, internal7-1.9 K LHe in, external8-1.9 K pumping, external9-1.9 K pumping, internal
Fresca
11-1.9 K pumping, internal12-1.9 K pumping, external13-LHe in, internal14-LHe in, external15-GHe return internal16-GHe return, external
HX
MIXMIX
Valve box shield
CD/WU
LN, shield
LHe
GHe return
1.9 K pumping
*On an outlet of 7 cryostats LN line continues directly to 163 CB or to LN phase separator and later on to 163 CB (if content of GN is too high).
*
Gazo/LP
Pre-cooling line
Gazo/LP
22 may 2017
Fresca 2 simplified schema
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 11
Internal cryostat
Current lead
External cryostat
Current lead
GHe outlet, warm
GHe outlet, warm
2
6
9
1
5
8
7
4
Internal cryostat
2-GHe return, internal6-LHe in, internal9-1.9 K pumping, internal
External cryostat
1-GHe return, external5-LHe in, external up7-1.9 K LHe in, external8-1.9 K pumping, external4-CD/WU, external down & filling
165 Combined valve box
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 12
CB 165
To filling station
Gazo/LP
Gazo/LP
Line 165/163 pre-cooling
LN
To B. 163
165 Dewar
LHe in
LHe out
LHe in
Cold GHe out
165 valve box
LN
LHe
GHe return
VB shield
Trailer Dewar
B. 165 existing simplified layout
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 13
B. 165 proposed preliminary layout
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 14
B. 163 proposed preliminary layout 3D,a
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 15
B. 163 proposed preliminary layout 3D, b
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 16
Extra civil
engineering
required
B.163 combine line at reverse side
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 17
B.163 combined line at reverse side, top view
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 18
Building 163 equipment
Approximate mass of components:• Dewar ≈ 9T
• Valve box ≈ 3T
• Fresca ≈ TBC (approx. 20 T)
• Fresca 2 ≈ TBC (approx. 20T)
Mass distribution:• Assuming mass is equally distributed over the area of the pit floor.
• Area of pit = 4.85 m * 2.43 m = 11.79 m²
• Total mass ≈ 50 T
• Distributed mass ≈ 4.24 T/m² (limit = 1T/m²)
Conclusion:• The current strength of the floor of the pit should be confirmed as the drawing is
old.
• If the drawing found is correct civil works may be required to strengthen the pit.
R.GUEYDAN - TE/CRG/ME19/06/2017
Cryogenic infrastructure for Fresca 2 in B.163
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 20
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
To 7 cryostats
To 165 Dewar
Cool down/warm up - external
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 21
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
LHe filling - external
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 22
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
LHe nominal inlet - external
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 23
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
1.9 K pumping - external
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 24
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
LHe to internal – cool down & filling
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 25
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
LHe internal - nominal
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 26
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
1.9 K circuit - internal
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 27
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
LN shield circuit
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 28
CB 163
HX
MIX
GN to atmosphere
Warm GHe outlet of CLs
Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line
Infrastructure for Fresca 2, optionvalves relocation from main valve box to local distribution valve boxes
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 29
Fresca 2, 9 lines Fresca, 6 lines
Fresca 2 distribution valve box, 5 valves
Fresca distribution valve box, 3 valves
163 valve box, 13 valves
To 1.9 K pumping unit
To 163 cold box
To 7 cryostats
To B. 165
163 LHe Dewar
LP
LPLP
Main combined line, 7 lines
F2 combined line. 4 lines
F combined line, 3 lines
Fresca 2
1-GHe return, external2-GHe return, internal3-LN in, shield4-CD/WU, external down5-LHe in, external up6-LHe in, internal7-1.9 K LHe in, external8-1.9 K pumping, external9-1.9 K pumping, internal
Fresca
11-1.9 K pumping, internal12-1.9 K pumping, external13-LHe in, internal14-LHe in, external15-GHe return internal16-GHe return, external
1 23 4 5 6 7 8 9 15 11 12 13 14 16
HP
Fresca 2 infrastructure - option
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 30
Fresca 2 infrastructure - option, top view
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 31
Planning
6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 32
1 week delay in
design phase