Post on 16-Apr-2022
transcript
zoetis.com
1. Please refer to direction insert for the species covered2. Mackay EM. The distribution of glucose in human blood (Scripps Metabolic Clinic). J Biological Chem. May 1932: 685-688. 3. Coldman MF, Good W. The distribution of sodium, potassium and glucose in the blood of some mammals. Comp Biochem Physiol. April 1967; 21(1): 201-206. 4. Data on fi le, Study Report No. 11-06-MC-D-CT-AT, Zoetis Inc. 5. Data on fi le, Study Report No. 11-07-VE-H-CT-AT, Zoetis Inc.6. See the codes shown in the direction insert7. Durham AE, McGowan CM, Fey K, et al. Pituitary pars intermedia dysfunction: diagnosis and treatment. Equine Vet Educ 2014;26(4):216-223.8. Durham AE, Hughes KJ, Cottle HJ, et al. Type 2 diabetes mellitus with pancreatic ß-cell dysfunction in 3 horses confi rmed with minimal model analysis. Equine Vet J 2009;41(9):924-929.9. Frank N, Geor RJ, Durham AE, et al. Equine metabolic syndrome. J Vet Intern Med 2010;24:467-475.10. Hackett ES, McCue PM. Evaluation of a veterinary glucometer for use in horses. J. Vet. Intern. Med. 2010;24:617-621.
All trademarks are the property of Zoetis Services LLC or a related company or a licensor unless otherwise noted. © 2016 Zoetis Services LLC. All rights reserved; ATK-00086
VETERINARY BLOOD GLUCOSE METER
1 AlphaTRAK blood glucose meter25 AlphaTRAK test strips1 lancing device30 blood sample lancets1 control solution1 user guide1 diabetes diary
ALPHATRAK STARTER KIT
◗ Accurately monitors blood glucose levels in newborn foals
◗ Helps determine the risk of laminitis linked with “Cushing’s disease” (malfunction in the pars intermedia of the pituitary gland) 7
◗ Calculates the risk of diabetes mellitus 7,8
◗ Confi rms insulin resistance linked with equine metabolic syndrome 9
◗ Similar results to those obtained using reference methods 5,10 and more accurate than portable human blood glucose meters 5
FOCUS: on horses
VETERINARY BLOOD GLUCOSE METER
DIAGNOSTICS BY ZOETIS
Calibrated for animals 1…
which makes all the di� erence!
Small sample volumeLong shelf life test strips
Extended measurement range
DESIGNED SPECIFICALLY FOR ANIMALS
Sampling on the left or right of the test strip Quick result
Inbuilt calibration for each species
Portable meterMore accurate than portable human blood glucose meters
IDEAL FOR GLUCOSE CURVES
AT25
D17 -
Adv
Alph
atra
k avr
il 17 -
Conc
eptio
n gra
phiqu
e : ©
Grou
pe A
xxes
s
VETERINARY BLOOD GLUCOSE METER
1 AlphaTRAK blood glucose meter25 AlphaTRAK test strips1 lancing device30 blood sample lancets1 control solution1 user guide1 diabetes diary
ALPHATRAK STARTER KIT
◗ Accurately monitors blood glucose levels in ◗ Confi rms insulin resistance linked with equine
FOCUS: on horses
1 µL0.6 µL
Size required for other commonly used blood
glucose meters
4 µL2 µL
AlphaTRAK sample size
Only 0.3 µL
Small volume of blood◗ The smallest sample volume on the market◗ Avoids blood draw: saves time, less stress for the
animal so reduced disturbance of blood glucose
DESIGNED SPECIFICALLY FOR ANIMALSWHY AlphaTRAK?
Portable blood glucose meters use whole blood to measure the glucose levels in plasma. They are calibrated to take into account the distribution of glucose between the plasma and red blood cells in humans. AlphaTRAK accounts for the fact that the distribution of glucose between the plasma and red blood cells changes depending on the animal species being tested 1, in order to provide an accurate and specifi c blood glucose reading.
1 • GLUCOSE IS DISTRIBUTED DIFFERENTLY in human and animal blood 2,3
Comparative studies show that blood glucose measured using AlphaTRAK in dogs, cats and horses is more accurate than when using portable blood glucose meters designed for humans. 4.5
2 • HUMAN BLOOD GLUCOSE METERS ARE NOT SUITABLE for animal health
10
0
-10
-20
-30
Percentage Bias from a Commercial Reference Laboratory* Commerical reference lab is at zero on this graph.
0.1 %
-22.71 %
-28.5 %
DOG 4
Zoet
is Al
phaT
RAK
Baye
r Co
ntou
r®
Roch
e Ac
cu-C
heck
® Av
iva
-1.6 %
-18.9 %-23 %
CAT 4
Zoet
is Al
phaT
RAK
Baye
r Co
ntou
r®
Roch
e Ac
cu-C
heck
® Av
iva
0.44 %
-20.4 % -18.9 %
HORSE 5
Zoet
is Al
phaT
RAK
Baye
r Co
ntou
r®
Roch
e Ac
cu-C
heck
® Av
iva
Extended measurement range ◗ Measurement of hyperglycaemia up to 750 mg/dL
(compared to 600 mg/dL for all the other meters on the market)
Long shelf life test strips◗ 18-24 months, even after opening, for easier
stock management
Blood sampling on the right or left of the test strip
◗ Practical, regardless of how the animal is restrained
Quick result◗ Rapid blood absorption thanks to a specifi cally-
designed test strip which breaks the meniscus of the blood drop
◗ Results displayed in just seconds, and only if there is a su� cient amount of blood (confi rmed by an audible “beep”)
◗ Saves time, in particular for creating glucose curves
More accurate than portable human blood glucose meters, as demonstrated by multiple studies 4,5
Inbuilt calibration for each species 1
◗ Takes into account the distribution of glucose in the blood, which is unique to each species covered
◗ Species-specifi c code, allows switching from cats to dogs (no changing of chips)
◗ Multi-species matching: ferret, horse, rat 6, mouse 6
Portable blood glucose meters use whole blood to measure the glucose levels in plasma. They are calibrated to take into account the distribution of glucose between the plasma and red blood cells in humans. AlphaTRAK accounts for the fact that the distribution of glucose between the plasma and red blood cells changes depending on the animal species glucose between the plasma and red blood cells changes depending on the animal species
7 %of glucose 3
93 %of glucose
42 %of glucose 2
58 %of glucose
12.5 %of glucose 3
87.5 %of glucose
Glucose Red Blood Cells Plasma
Portable meter ◗ Results are ready in seconds and can be
communicated directly to the owner during the visit
◗ For an easy transition from exam room to kennel