Voltage Tester Used for testing voltage on electrical outlets, fuse clips, and circuit breakers will...

Post on 17-Jan-2016

217 views 1 download

Tags:

transcript

Voltage Tester

Used for testing voltage on electrical outlets, fuse clips, and circuit breakers will test voltage from 120 to 600 volts.

Continuity Tester

A device used to the continuity of a circuit.

Multi-Tester or Volt-Ohm Meter

An analog or digital meter that commonly will measure AC volts, DC volts, Ohms, and milli-amps.

Wire Stripper

Used to strip plastic coating from solid electrical wires without damaging the wire .Can be adjusted to be used on various wire sizes.

Lineman's Pliers

They are used on both bare and insulated wire. Note: These tools are also used for fence work and tying concrete rebar.

NM Cable Cutter

A cutter for cutting Type NM cable.

Long Nose Pliers

Also used for stripping wire, making eyes in wire and holding wire in place while inserting screws.

Wire Stripper And Crimping Tool

Used for stripping wire, cutting wire and crimping wire terminals on stripped wire ends.

Fuse Puller

Made of plastic to prevent electrician from being shocked while installing or removing fuses.

Fish Tape

Fish tapes come in 25, 50 and 100 foot lengths.

Armored Cable

This cable must run from box to box without splices.

Knife Fuse

The knife fuse is made in several sizes for service of 60 to 600 amps and is not interchangeable with cartridge fuses or knife fuses of different capacities.

Circuit Breaker

Used to protect the wire in a circuit. Rated in amps.

Wire Nut

Used to connect AC wires. Color coded to denote capacity.

Solderless Connector

Used where a permanent connection is desired. Connectors can be insulated or un-insulated. Commonly used for wiring on mobile equipment.

Friction Tape

Used over rubber insulating tape on wire Splices and is used to replace the outer braid.

Plastic Tape

It is used alone without friction tape.

Electric Cord

A flexible cable used for extension cords and connecting power tools. May be plastic (e.g. Type xx) or rubber covered (e.g.. Type SJ)

Conduit Straps

Conduit is placed in the curved portion and strap is secured by nails or screws. Single foot and double foot styles. Sized for EMT and rigid/PVC conduit.

Cartridge Fuse

It is a cylinder shaped like a cartridge case and has metal ferrules at each end and a soft fusible element inside.

Non-Metallic Clamp

The cable is secured by means of a bracket tightened with screws. Used to secure a NM cable to a box.

UF Cable

A solid plastic covering is used on this cable making it suitable for direct burial of the cable. UF cable is sized like NM cable.

Single Conductor

A single conductor with thermal plastic insulation. Wire may be solid or stranded. Typical types are TW and THHN. Common sizes 14-0

Non-Metallic Cable

A cable with a plastic cover used for residential indoor wiring. Commonly found with 3 and 4 conductor in sizes 14-6. For example "14-2 w/ ground" will have 3 14 gauge conductors, 1 black, one white, and one bare.

Rubber Tape

Used on high voltage connections. It is covered with friction tape or plastic tape.

Service Entrance Panel (SEP)

Used to distribute power in a building. Contains a main disconnect and circuit breakers.

Flexible Conduit

It consists of a heavily zinc coated steel strip wound spiraling, with interlocked construction permitting greater flexibility.

Electrical Metallic Tubing

A thin walled conduit. Commonly abbreviated as EMT. It is coupled with special fittings and is smooth inside. Manufactured in 10 foot lengths. Common sizes 1/2"-2". Approved for indoor use.

Ridged Conduit

It is available in galvanized and enamel finishes.

Cord Cap

It is some times called a male plug. Used on extension cords and power tool cords.

Cord Connectors

This connecting body is designed to accommodate the cord cap and is sometimes called a female plug.

Lampholder

A plastic or porcelain device that holds a lamp.

Duplex Receptacle

Receptacles may be installed in outlet boxes flush with the wall or in surface mounted boxes or junction boxes.

Switch Box

Comes with knockouts for non-metallic sheathed cable or electrical metallic tubing. Boxes must be covered either with a cover or a fixture.

Plastic Box

Commonly constructed of PVC plastic and used with NM cable. May be attached with nails (shown) or screws. Comes in 1 -4 gang sizes and varying depths.

Junction Box

Usually made of metal in square or octagon shaped boxes. Boxes must be covered either with a cover or a fixture.

Box Cover

Used to cover a device such as a switch or DR. May configurations are available.

Surface Cover

Used with 4" junction boxes to adapt the box to a specific device when the box is mounted on the surface of a wall. In this case a switch and DR, but they come in many configurations. Blank (flat) covers are also used when no device is mounted in the box.

Toggle Switch

When the toggle switch is pushed up the service is on and off when pushed down.

Three-Way Toggle Switch

Traveler or go between wires connect to lighter colored brass screws; hot wire is connected to the darker colored brass screw.