WBKY FM TOWER RUTLAND, WISCONSIN ZONING DRAWINGS · title sheet a-1 c-2 c-1 1-3 t-1 c c c c c...

Post on 16-Jul-2020

1 views 0 download

transcript

T-1

TIT

LE S

HE

ET

SITE LOCATION MAPS

MEMBER

ON

EC

AL

L

SYSTEMS

INT

ER

NA

TI

ON

AL

TELCO SERVICE PROVIDER:

ELECTRIC SERVICE PROVIDER:

UTILITY INFO:

TO OBTAIN LOCATION OF PARTICIPANTS’ UNDERGROUND FACILITIES BEFORE YOU DIG IN

TOLL FREE:1-800-242-8511 OR

FAX A LOCATE 1-800-338-3860

WISCONSIN, CALL DIGGER’S HOTLINE

NOTICE BEFORE YOU EXCAVATE

REQUIRES MIN. OF 3 WORK DAYS

WI STATUTE 182.0175 (1974)

SHEET INDEX:

PAGE TITLE:NO.: REV.

* PREPARED BY OTHERS

PROJECT DIRECTORY: PROJECT INFORMATION:

Signature:

Date:

ENGINEER SEAL:

NOT F

OR CONS

TRUC

TION

PRELIMINAR

Y -

NORTH

SITE LOCATION

4/8/2011

T-1.dgn

PROJECT #:

5080

SHEE

T TITL

E:

A

B

C

D

E

0

1

2

3

4

STAMPED FINALS:

PRELIMINARY CDS:

CHECKED BY:

PLOT DATE:

FILE NAME:

DRAWN BY:

SHEET NUMBER:

C EDGE CONSULTING ENGINEERS, INC.

I:\50

00\5

080\

CA

D\Plot\

ZDs\

T-1.dgn

Ed

ge

ww

w.edgeconsult.co

m

608.64

4.15

49 fax

608.64

4.14

49 voice

Prairie du Sac, WI 53

578

624

Water Street

Co

ns

ultin

g E

ngin

eers, In

c.

UNDER THE LAWS OF THE STATE OF WISCONSIN.

A DULY LICENSED PROFESSIONAL ENGINEER

NOTED IN THE SHEET INDEX, AND THAT I AM

SUPERVISION OTHER THAN THE EXCEPTIONS

PREPARED BY ME OR UNDER MY DIRECT

I HEREBY CERTIFY THAT THIS PLAN SET WAS

CJL

DCL

PRELIM ZDS - 08/02/2010

1.800.862.6222

ALLIANT ENERGY

1.800.483.1000

VERIZON NORTH

PRELIM ZDS - 08/29/2010

ZONING DRAWINGS

RUTLAND, WISCONSIN

WBKY FM TOWER

RU

TL

AN

D,

WIS

CO

NSIN

WB

KY F

M T

OW

ER

PHONE: 414.507.3751

CONTACT: DICK ROGERS

WHITEFISH BAY, WI 53217

100 W. HENRY CLAY STREET

WIRELESS PLANNING, LLC.

SITE ACQUISITION:

PHONE: 608.372.9600

CONTACT: DAVE MAGNUM

TOMAH, WI 54660

1021 N. SUPERIOR AVE.

MAGNUM COMMUNICATIONS, INC.

CLIENT:

FAX: 608.644.1549

PHONE: 608.644.1449

CONTACT: DAVE LYSHEK

PRAIRIE DU SAC, WI 53578

624 WATER STREET

EDGE CONSULTING ENGINEERS, INC.

ENGINEERING COMPANY:

APRIL 2011

489’ GUYED TOWER

PRELIM ZDS - 04/06/2011

TOWER ELEVATION

COMPOUND PLAN

SITE PLAN

SITE SURVEY*

TITLE SHEET

A-1

C-2

C-1

1-3

T-1

C

C

C

C

C

0510-341-8150-0

0510-341-9590-0

0510-341-9000-9

TAX KEY NUMBER:

WISCONSIN

DANE COUNTY

TOWN OF RUTLAND,

SECTION 34, T.5N, R.10E,

OF THE NE 1/4,

PART OF E1/2 & THE S 1/2

PLSS INFORMATION:

OREGON, WI 53575

4198 OLD STONE ROAD

STOUGHTON FARMS

PROPERTY OWNER:

OREGON, WI 53575

3768 OLD STAGE ROAD

E911 TBD

SITE LOCATION:

4/8/2011

C-1.dgn

PROJECT #:

5080

SHEE

T TITL

E:

A

B

C

D

E

0

1

2

3

4

STAMPED FINALS:

PRELIMINARY CDS:

CHECKED BY:

PLOT DATE:

FILE NAME:

DRAWN BY:

SHEET NUMBER:

C EDGE CONSULTING ENGINEERS, INC.

I:\50

00\5

080\

CA

D\Plot\

ZDs\

C-1.dgn

Ed

ge

ww

w.edgeconsult.co

m

608.64

4.15

49 fax

608.64

4.14

49 voice

Prairie du Sac, WI 53

578

624

Water Street

Co

ns

ultin

g E

ngin

eers, In

c.

CJL

DCL

PRELIM ZDS - 08/02/2010

PRELIM ZDS - 08/29/2010

RU

TL

AN

D,

WIS

CO

NSIN

WB

KY F

M T

OW

ER

PRELIM ZDS - 04/06/2011

950’

951’

952’

953’

954’

954’

955’

955’

955’

955’

955’

955’

956’

956’

956’

957’

957’

95

7’

957’

958’

958’

958’

958’

958’

959’

959’

959’

959’

959’

960’

960’

960’

960’

960’

961’

961’

961’

96

2’

962’

962’

963’

963’

963’

963’9

64’

965’

965’9

66’967’968’969’

969’

970’

970’

970’

970’

971’

972’

972’

972’

973’

973’

973’

971’

C-1

SIT

E P

LA

N

0

SCALE: 11" x 17" - 1" = 300’-0"22" x 34" - 1" = 150’-0"

NORTH

150’-0" 150’-0" 300’-0"BIRD’S EYE PHOTOPROPOSED SITE

PROPOSED TOWER LOCATION

PARCEL TO BE PURCHASEDAPPROX. LOCATION OF

EXISTING R.O.W.

EXISTING R.O.W.

EXISTING R.O.W.

EXISTING BUILDINGS

OLD STAGE ROAD

SECTION LINESECTION LINE

SECTIO

N LIN

E

SECTION LINE / PROPERTY LINESECTION LINE

SECTIO

N LIN

E

SECTIO

N LIN

E

SECTION LINE

SECTION LINE / PROPERTY LINE

SECTIO

N LIN

E / PROPER

TY LIN

E

SECTIO

N LIN

E / PROPER

TY LIN

E

66’-0"OF PARCEL TO BE PURCHASEDPROPOSED 66’ WIDE ACCESS PORTION

PROPOSED PROPERTY LINE

BE MOWED & MAINTAINED FOR SITE ACCESSPROPOSED 12’ WIDE GRASS STRIP TO

EXISTING FIELD LINE

WOODS

WOODS WOODS

725’-5"

709’-2"

775’-3"

PROPOSED 489’ GUYED TOWER

COMPOUND & EQUIPMENT SHELTERPROPOSED 20’ x 20’ FENCED

316’-10"

410’-5"

ANCHOR FENCE (TYPICAL)PROPOSED 3’ x 22’ GUY

(APPROX. 15.47 ACRES)= 673,947 SQUARE FEET

PURCHASED, TOTAL AREAPROPOSED PARCEL TO BE

UTILITIES, APPROX. 2100’ FROM R.O.W.EXACT SOURCE & ROUTING WITH LOCALPROPOSED BURIED UTILITIES, VERIFY

AG FIELD

AROUND GUY ANCHORPROPOSED TREE CLEARING

UNTILLED

UNTILLED

(50% OF TOWER HEIGHT)DEBRIS FALL RADIUS

(25% OF TOWER HEIGHT)GROSS TOWER MAST FALL RADIUS

(80% TOWER HEIGHT)PROPOSED 391.2’ GUY WIRE

(40% TOWER HEIGHT)PROPOSED 195.6’ GUY WIRE

92’-9" +/-

74’-9" +/-

4/8/2011

C-2.dgn

PROJECT #:

5080

SHEE

T TITL

E:

A

B

C

D

E

0

1

2

3

4

STAMPED FINALS:

PRELIMINARY CDS:

CHECKED BY:

PLOT DATE:

FILE NAME:

DRAWN BY:

SHEET NUMBER:

C EDGE CONSULTING ENGINEERS, INC.

I:\50

00\5

080\

CA

D\Plot\

ZDs\

C-2.dgn

Ed

ge

ww

w.edgeconsult.co

m

608.64

4.15

49 fax

608.64

4.14

49 voice

Prairie du Sac, WI 53

578

624

Water Street

Co

ns

ultin

g E

ngin

eers, In

c.

CJL

DCL

PRELIM ZDS - 08/02/2010

PRELIM ZDS - 08/29/2010

RU

TL

AN

D,

WIS

CO

NSIN

WB

KY F

M T

OW

ER

PRELIM ZDS - 04/06/2011

C-2

0

SCALE:

3’-0" 3’-0" 6’-0"

NORTH

CO

MP

OU

ND P

LA

N

C-2

AEXISTING SITE

LOCAL UTILITIES, APPROX. 2100’ FROM R.O.W.EXACT SOURCE & ROUTING WITH

PROPOSED BURIED UTILITIES, VERIFY

& TELCO PEDESTALPROPOSED TRANSFORMER

30’-0"

10’-0"

10’-0"

10’-0"10’-0"

10’-0"

4’-0"

12’-0"

4’-0"

ICE BRIDGEPROPOSED 10’ LONG

GUYED TOWERPROPOSED 489’ TALL

PROPOSED 12’ WIDE DOUBLE SWING GATE

PROPOSED 20’-0" FENCED COMPOUND

UNTILLED

PROPOSE

D 20’-0" FE

NCED C

OM

PO

UN

D

22" x 34" - 1" = 3’-0"11" x 17" - 1" = 6’-0"

& 200’ G

UY WIRE, APP

ROX. 40% TO

WER HEIGHT

PROPO

SED 400’ G

UY WIRE, APP

ROX. 80% TO

WER HEIGHT (T

YP.)

UNTILLED

GRASS LANE TO SITEPROPOSED

UNTILLED UNTILLED

FENCED COMPOUNDPROPOSED CHAIN LINK

SING (TYPCIAL EA. SIDE)PROPOSED "NO TRESPASSING"

SING (TYPCIAL EA. SIDE)PROPOSED "NO TRESPASSING"

WEST, SOUTH, AND EASTWOODLINES TO THE

AND COMPLIMENT EXISTINGVISUALY SCREEN COMPOUNDPROPOSED LANDSCAPING TO

PROVIDERS SPECIFICATIONSTO MEET LOCAL UTILITY

PROPOSED UTILITY RACK

EQUIPMENT SHELTER (EXACT SHELTER TBD)PROPOSED 10’ x 20’ MAGNUM COMMUNICATIONS

4/8/2011

A-1.dgn

PROJECT #:

5080

SHEE

T TITL

E:

A

B

C

D

E

0

1

2

3

4

STAMPED FINALS:

PRELIMINARY CDS:

CHECKED BY:

PLOT DATE:

FILE NAME:

DRAWN BY:

SHEET NUMBER:

C EDGE CONSULTING ENGINEERS, INC.

I:\50

00\5

080\

CA

D\Plot\

ZDs\

A-1.dgn

Ed

ge

ww

w.edgeconsult.co

m

608.64

4.15

49 fax

608.64

4.14

49 voice

Prairie du Sac, WI 53

578

624

Water Street

Co

ns

ultin

g E

ngin

eers, In

c.

CJL

DCL

PRELIM ZDS - 08/02/2010

PRELIM ZDS - 08/29/2010

RU

TL

AN

D,

WIS

CO

NSIN

WB

KY F

M T

OW

ER

PRELIM ZDS - 04/06/2011

A-1

TO

WE

R E

LE

VA

TIO

N

A

A-1 SCALE:

TOWER PROFILE (SOUTH ELEVATION)

22" x 34" - 1" = 30’-0"11" x 17" - 1" = 60’-0"

ALL ANTENNA AZIMUTHS TO BE FROM TRUE NORTH

ANTENNA WITH PROJECT MANAGERCONTRACTOR TO VERIFY HEIGHT AND DIRECTION OF

REPRESENT ACTUAL CONDITIONSFOUNDATIONS SHOWN ARE TYPICAL AND DO NOT

NOTES:

EQUIPMENT SHELTER (EXACT SIZE TBD)PROPOSED MAGNUM COMMUNICATIONS

GUYED TOWERPROPOSED 489’

LIGHTNING ROD & BEACONPROPOSED TOP OF TOWER

COMMUNICATIONSSIZE & ELEVATION TBD BY MAGNUM

PROPOSED FM ANTENNAS, EXACT

PROP

OSED G

UY WIRE (T

YP.) - 400’ RA

DIUS; 80% TO

WER HEIG

HT

200’-0" FROM TOWER CENTER (40% TOWER HEIGHT)

400’-0" FROM TOWER CENTER (80% TOWER HEIGHT)

PROPO

SED

GUY WIRE (TYP.) - 200’ R

ADIUS; 40

% TO

WER HEIG

HT

PROPOSED MID-TOWER LIGHTING BEACON

LIGHTING BEACONPROPOSED 1/4 TOWER

LIGHTING BEACONPROPOSED 3/4 TOWER

OVER

ALL T

OW

ER H

EIG

HT

W/

APPURTE

NA

NCE 48

9’-0" A

GL

MANUFACTURER RECOMMENDATIONS.INSTALLATION AND HARDWARE REQUIREMENTS WITH EXACT TOWER LIGHTING KITS TO BE DETERMINED. VERIFY EXACT

TOWER LIGHTING SYSTEM TO FOLLOW FAA ADVISORY CIRCULAR .

TOWER LIGHTING NOTES: