28
© 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability Carbon Neutrality and Buildings The Design Process Overview: Steps to Carbon Neutral Design Optimizing the Building Envelope with Respect to Daylighting Design Goals Management of Solar Heat Gain Natural Ventilation Minimizing Internal Loads with Natural Ventilation Onsite Renewable Energy
Transcript
Page 1: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Autodesk Sustainable Design Curriculum

Lesson Five: Optimizing the Design of the Building Envelope for Sustainability

Carbon Neutrality and Buildings The Design Process Overview: Steps to Carbon Neutral Design Optimizing the Building Envelope with Respect to Daylighting Design Goals Management of Solar Heat Gain Natural Ventilation Minimizing Internal Loads with Natural Ventilation Onsite Renewable Energy

Page 2: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

2030 Voluntary Carbon Neutral Initiative

Architecture 2030, a nonprofit, nonpartisan, and independent organization founded by architect Edward Mazria, has issued The 2030 Challenge asking the global architecture and building community to adopt the following targets:

All new buildings, developments, and major renovations shall be designed to meet a fossil fuel, GHG-emitting, energy-consumption performance standard of 50% of the regional (or country) average for that building type.

At a minimum, an equal amount of existing building area shall be renovated annually to meet a fossil fuel, GHG-emitting, energy-consumption performance standard of 50% of the regional (or country) average for that building type.

Increase the fossil fuel reduction standard for all new buildings to:

60% in 201070% in 201580% in 202090% in 2025

Carbon-neutral in 2030 Achieve these targets by implementing innovative sustainable design strategies, generating

onsite renewable power, and/or purchasing (20% maximum) renewable energy and/or certified renewable energy credits.

Page 3: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

2030 Voluntary Carbon Neutral Initiative

U.S. Conference of Mayors (Resolution #50; unanimously passed) (USCM) The American Institute of Architects (AIA)U.S. Green Building Council (USGBC)Royal Architecture Institute of Canada (RAIC)County of Sarasota, FLState of New Mexico (Governor Bill Richardson)City of Santa Fe, NMCounty of Santa Fe, NMCity of Albuquerque, NMCity of Plano, TXRocky Mountain Institute (RMI)International Council for Local Environmental Initiatives (ICLEI)World Business Council for Sustainable Development (WBCSD)Environmental Protection Agency (EPA/Target Finder)American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE)National Wildlife Federation (NWF)Society of Building Science Educators (SBSE)AIA Committee on the Environment (AIA/COTE)Association of Collegiate Schools of Architecture (ACSA)Union Internationale des Architectes (UIA)American Solar Energy Society (ASES)

The following organizations have already adopted these targets:The following organizations have already adopted these targets:

Page 4: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Carbon Neutrality and Buildings

The definition of what constitutes a carbon neutral building is in flux, with no uniform definition existing among the regulatory or design community.

A carbon neutral building, (as defined by the Autodesk Green Building Studio web service) accounts for regional differences in the carbon footprint of the regional electric grid, and mandates that any fossil fuel-based electricity and fuel use be eliminated through efficiency gains or offset by onsite nonfossil fuel-based energy sources such as PV or wind energy.

Carbon neutrality is often used interchangeably with net-zero energy consumption.

A net-zero energy project is defined as a project/building that consumes only what it produces with respect to energy, on an annual basis.

Renewable noncarbon sources are required to meet the typical definition of a net-zero energy building.

Noncarbon renewable sources include wind energy, solar energy, and biofuels.

In some cases, partial renewable energy “credits” are assigned for certain technologies such as geothermal heat pumps, which use the earth as a heat source/sink.

The definition of what constitutes a carbon neutral building is in flux, with no uniform definition existing among the regulatory or design community.

A carbon neutral building, (as defined by the Autodesk Green Building Studio web service) accounts for regional differences in the carbon footprint of the regional electric grid, and mandates that any fossil fuel-based electricity and fuel use be eliminated through efficiency gains or offset by onsite nonfossil fuel-based energy sources such as PV or wind energy.

Carbon neutrality is often used interchangeably with net-zero energy consumption.

A net-zero energy project is defined as a project/building that consumes only what it produces with respect to energy, on an annual basis.

Renewable noncarbon sources are required to meet the typical definition of a net-zero energy building.

Noncarbon renewable sources include wind energy, solar energy, and biofuels.

In some cases, partial renewable energy “credits” are assigned for certain technologies such as geothermal heat pumps, which use the earth as a heat source/sink.

Page 5: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Why Is a Process Change Essential for Design of Carbon Neutral Buildings?

BIM tools, such as Autodesk Revit Architecture, enable architects to analyze their schematic designs using various software tools that can carry out robust energy analyses in minutes.

The process of submitting schematic designs for energy analysis can and must be repeated as a design progresses, in order to compare results and minimize resource use for various configurations of building form, product selection, and environmental response.

This iterative approach and the need to begin analyses early in the design process is a fundamental departure from traditional approaches that involve specifying efficient components late in the design process.

It must be emphasized that the design process is iterative, repeating design process steps as the team moves ever-closer to an optimal carbon neutral design.

BIM tools, such as Autodesk Revit Architecture, enable architects to analyze their schematic designs using various software tools that can carry out robust energy analyses in minutes.

The process of submitting schematic designs for energy analysis can and must be repeated as a design progresses, in order to compare results and minimize resource use for various configurations of building form, product selection, and environmental response.

This iterative approach and the need to begin analyses early in the design process is a fundamental departure from traditional approaches that involve specifying efficient components late in the design process.

It must be emphasized that the design process is iterative, repeating design process steps as the team moves ever-closer to an optimal carbon neutral design.

Page 6: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Process Change is Essential for Effective Sustainable Design

Page 7: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Iterate to Improve Design and Reduce Energy Use

Page 8: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Residential vs. Commercial Buildings: A Brief Primer

0%

5%

10%

15%

20%

25%

30%

35%

% o

f T

ota

l Bu

ildin

g E

ner

gy

Use

Spa

ce H

eatin

g

Ligh

ting

Spa

ce C

oolin

g

Wat

er H

eatin

g

Ref

riger

atio

n

Ele

ctro

nics

Coo

king

Ven

tilat

ion

Com

pute

rs

Oth

er

Comparison of Energy End Use

Residential

Commercial

Source: 2005 Buildings Energy Data Book, 2003 data

The graph illustrated compares the percentage of energy end-use for residential buildings in the U.S. compared to commercial buildings in the U.S. As you can see, in residential buildings, the largest percentage of energy is devoted to space heating—nearly 35%; however, in commercial buildings, space heating comprises only about 16% of the total building energy end-use.

This tells us that measures that reduce heating loads (passive solar design, increased levels of insulation, windows with a lower u-value) play a larger role in designing carbon-neutral houses than in designing carbon neutral commercial buildings.

Page 9: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

The Design Process Overview – Steps to Carbon Neutral Design

1. Set Savings Target

2. Optimize Site and Building Form and Openings

3. Minimize Internal and External Loads

4. Select HVAC System

5. Onsite Renewables

6. Commissioning

7. Purchase Green Power & Carbon Credits

Page 10: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

The Design Process Overview – Steps to Carbon Neutral Design

Set Savings Target

How will you know if your design has “arrived” if you do not first determine a destination?

Without establishing an energy savings target, the architect is “working blindly.” There are many Fossil Fuel Reduction Goals established by prominent organizations, including the following:

• A carbon neutral building, as defined by ASHRAE Standard 189, the U.S. EPA (draft only) and others.

• A net-zero energy project annually consumes only what it produces.

• American Institute of Architects – “Promote integrated/high performance design including resource conservation resulting in a minimum 50% or greater reduction in the consumption of fossil fuels used to construct and operate new and renovated buildings by the year 2010 and promote further reductions of 10% or more in each of the following 5 years.” - High Performance Building Position Statements ©2005, The American Institute of Architects, Washington, DC.

• Architecture 2030 – “All new buildings and major renovations reduce their fossil-fuel GHG-emitting consumption by 50% by 2010, incrementally increasing the reduction for new buildings to carbon neutral by 2030.”

• U.S. Green Building Council – All new commercial LEED projects are required to reduce CO2 emissions by 50 percent when compared to current emission levels.

• U.S. Conference of Mayors – Adopted the “2030 Challenge” for City Buildings and calls on the Conference of Mayors to increase the fossil-fuel reduction standard for all new buildings to carbon neutral by 2030

Page 11: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Optimizing the Building Envelope with Respect to Daylighting Design Goals

A general rule of thumb is that the daylighting zone may be considered to be a depth of about 1-1/2 to 2 times the window head height.

For example, if a space has windows with a head height of six feet, it may be feasible to daylight up to about 12 feet deep into the space (assuming no internal partitions block the light).

A narrow building will have a greater proportion of its interior in the usable daylight zone.

Daylight penetration can be increased to up to 2.5 times the window head height by using light shelves or other means of reflecting the light farther into the space.

Light shelves simultaneously shade and reflect incoming daylight Source “Daylighting” http://www.arch.hku.hk/~kpcheung/teaching/b4link/b4-link1.htmLight shelves simultaneously shade and reflect incoming daylight Source “Daylighting” http://www.arch.hku.hk/~kpcheung/teaching/b4link/b4-link1.htm

Page 12: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Window Materials, Light Levels, and Thermal Tradeoffs

Cool daylighting design carefully controls light entering the building using several key techniques:  

• Exterior shading prevents too much direct sunlight from entering the building.

• Carefully placed windows admit light up high, where it illuminates the ceiling (simulating our experience of the sky) and shines deep into a building's interior.

• High-performance, low-transmittance glass prevents glare from interfering with computer-based tasks, but the visible transmittance of the glass must be balanced with the need to bring in sufficient, high-quality daylight.

• High performance glazing (low solar heat gain) also generally reduces the required size of the HVAC system, peak electrical demand, lifetime building energy use, and ongoing maintenance costs for a facility. In addition, through first cost reallocation, it is also less expensive than that portion of the HVAC system it replaces.

• Window blinds offer extra shading when the sun is low in the sky or if total darkness is needed.

• Paint and fabric colors, when carefully chosen, can maximize reflected light and minimize potential glare.

(Source: The Daylighting Collaborative, http://www.daylighting.org)

Page 13: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Window Materials, Light Levels, and Thermal Tradeoffs

The most important interior light-reflecting surface is the ceiling.

Using high reflectance surfaces will better bounce daylight around the room and also reduce extreme brightness contrast.

The daylight that arrives at a work surface comes from three sources:

1. The exterior reflected component, which includes: • Ground surfaces• Pavement• Adjacent buildings• Wide windowsills• Other objects

2. The direct sun/sky component

3. The internal reflected component

Once daylight enters a room, the surrounding wall, ceiling, and floor surfaces become important light reflectors. Once daylight enters a room, the surrounding wall, ceiling, and floor surfaces become important light reflectors.

Page 14: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Modeling DaylightModeling of sunlight on the exterior facade of a building, and how it casts shade and creates shadows on various surfaces, is relatively easy.

Most 3D CAD applications can model the movement of the sun in the sky at any time of the day and year for any location globally.

These tools are now increasingly able to model the contributions of diffuse light from the sky and interreflection.

Modeling daylit interiors is a far more challenging matter.

Most sunlight entering inside the building needs to be controlled by numerous fenestration features that help to diffuse, redirect, and distribute it.

Three tools that capture all these aspects of daylight design are Radiance (http://radsite.lbl.gov/radiance/) and Autodesk® Ecotect® and Autodesk® 3ds Max® software.

The Autodesk Green Building Studio tool automatically analyzes qualification for the LEED daylighting credit.

Page 15: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

WindowsProperly placed windows and other openings are indispensable for both daylighting and natural ventilation strategies.

Natural ventilation cooling strategies must be complemented by effective control of solar gains. Typically, light from a window is able to penetrate a depth of approximately 15 feet into a space for daylighting purposes.

Some important definitions relating to glass and windows are:

• U-value or U-factor indicates how well a window resists conduction. The rate of heat conductivity is indicated by the U-value (inverse of the R-value) of a window assembly. The lower the U-value, the greater a window’s resistance to conductive heat flow and the better its insulating value.

• SHGC measures a window's ability to block radiant heat transfer, typically from sunlight. The SHGC is the fraction of incident solar radiation admitted through a window. SHGC is expressed as a number between 0 and 1. The lower a window's solar heat gain coefficient, the less solar heat it transmits.

• Visible light transmittance (Tvis or VLT) measures the transmission of visible light. The visible transmittance is an optical property that indicates the amount of visible light transmitted. Most VLT values are between 0.3 and 0.8. The higher the VLT, the more light is transmitted. A high VLT is typically desirable to maximize daylight; however, too much light transmission can cause glare.

Page 16: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Skylights and Roof Glazing How much roof glazing is enough?

For 100% daylighting from traditional skylights, approximately 5% of roof area should be in skylights, (5% Skylight-to-Roof Ratio or SRR).

In general, a high VLT/SHGC ratio is desirable, but the ideal skylight specification depends on climate. All climates should have high visible transmittance (Tvis or VLT).

Hot climates should have low SHGC. It is almost always cheaper to use skylights to light a space than photovoltaic panels to generate renewable electricity that would be used in turn to power electric lighting.

• Tubular skylights require a much lower SRR than traditional skylights, approximately 1-2%.• U-value is more important in cold climates and has energy and condensation implications:

the lower the U-value, the greater the insulation value.• Dampers (to darken space) are available with most skylights.

Page 17: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Management of Solar Heat Gain Once you have explored a variety of daylighting strategies, it is essential to consider the implications each of these strategies has on solar heat gain.

BIM tools can enable designers to assign measures of density, solar absorption, and solar transmittance relevant to the analysis of solar heat gain to each specific building component, including: 

• External exposed thermal mass• Windows and doors• Curtain walls, masonry, and envelopes• Internal exposed thermal mass (walls, floors ceilings and casework, and so on) • Insulation

BIM tools can be leveraged to enable a designer to experiment with and consider the following in their design:  

• Experiment with a variety of building massing models and layouts in a variety of orientations to discover how they affect penetration of daylight.

• Experiment with a variety of reflective devices, including light shelves.• Experiment with a variety of wall and ceiling treatments (exposed materials, colors,

shades and tints of paint, tiles, and other surface treatments), and also consider the psychological impacts of color.

Consider different glazings with varying visible light transmittances and tints.

Page 18: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Management of Solar Heat GainSolar Heat Gain Rules of Thumb

In cold climates, for optimal performance:

• Heat-gaining spaces should face within 15 degrees of true solar south. In most parts of the U.S., optimizing for solar orientation can cut total energy usage by 30 to 40 percent at no additional cost.

• The building's south face should receive sunlight between the hours of 9:00 a.m. and 3:00 p.m. (sun time) during the heating season.

• Expose thermal mass and its properties during the heating season; in a direct gain system, the thermal mass floors and walls are functional parts of the building.

• For every square foot of south-facing glass, use 150 pounds of masonry or 4 gallons of water for thermal mass.

The surface area of mass should be six times the area of the accompanying glazing; less may be necessary in overcast climates. Consider different glazings with varying visible light transmittances and tints.

Page 19: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Material Choices for Management of Solar Heat GainMetal Framing: While valued for its structural benefits and recycled content, metal framing has the drawback of a lower assembly insulation value than a wood-framed component has because of the high conductivity of the metal. It is critical to ensure that metal-framed buildings use thermal breaks, both for energy and moisture reasons. Wood Framing: Wood construction offers a better overall insulation quality than steel, but it is not suitable for high-rise construction. Also, wood is vulnerable to insect damage and rot. High Mass Construction Materials: The use of concrete/brick/stone and other high mass materials for building facades is typically limited to low-rise buildings for cost and structural reasons. In climates with large diurnal temperature swings, high mass buildings may be able to store energy if the building’s interior temperature is allowed to float and if the mass is “charged” during the warm or cool hours. Insulation (R-Value): Does your project need a low conduction (High R-value) roof and/or walls for high performance? It depends on the building type, climate, and occupancy schedule. You need to perform whole building energy analysis on your project to answer the question. Continuous Insulation: Insulation that covers the framing members and thereby provides a greater insulation value. This is especially important for metal framing to control condensation. Cool Roof: The use of reflective roofing materials or cool roof systems is one means of keeping solar heat out of buildings and increasing energy savings. Cool roofs (generally white) stay as much as 70 degrees F cooler at peak times than traditional asphalt roofs, offering important benefits to building owners and also protecting the environment from the negative effects of urban heat islands. glazings with varying visible light transmittances and tints.

Page 20: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Material Choices for Management of Solar Heat GainGreen or Living Roof: Green roofs, garden roofs, or planted roofs are “specialized roofing systems that support vegetation growth on rooftops.”

Researchers have analyzed the thermal performance of green roofs using three different approaches: field experimentation, numerical studies, and a combination of laboratory or field experiments with numerical models.

All three types of analysis have confirmed that green roofs can significantly reduce heat transfer between building and outside environment.

This reduction in heat transfer can lead directly to energy savings and cost reduction for the building owner.

One study measured a 75% reduction in average daily demand for space conditioning. glazings with varying visible light transmittances and tints.

Page 21: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Material Choices for Management of Solar Heat GainNon-Traditional Construction Materials and Methods

• Structural Insulated Panels (SIPs) are rigid panels of foam insulation joined to oriented strand board (OSB). They are typically used as floors, walls, and roofs on smaller buildings. Benefits of using SIPS in construction generally include lower labor cost, less job-site waste, shorter construction time, and better-insulated buildings. SIPS are prefabricated in the factory with window openings and electrical/plumbing chases. Especially in the case of larger projects, the use of SIPS should be considered based on economies of scale. Outside finishes can be customized to meet whatever “look” is desired. More information about this technology, including links to suppliers, can be found at www.sips.org.

• Insulated Concrete Forms (ICFs) are forms/molds or hollow blocks with built-in insulation. These are stacked and filled with reinforcing bar and concrete.

Both SIPS and ICFs have a typical insulation value of approximately R5 per inch. ICFs also have thermal mass benefits. Both also reduce infiltration/noise.

• Straw Bales: Many factors can affect the insulating quality of a straw bale wall, including moisture content, bale size, and bale orientation. Autodesk Green Building Studio has adopted the California Energy Commission’s default assumption insulation value of R-30 for Straw Bale construction.

• Radiant Barriers: Radiant barriers consist of shiny “foil” like materials that lessen the ability of a hot surface to transfer heat by radiation to adjacent surfaces. Consider specifying a layer of radiant barrier film to the underside of the roof decking for those areas with plenums, and foil-faced insulation for those areas where the insulation is at the roof deck. This measure effectively cuts down the radiant heat entering the space directly below the roof, which means mechanical systems face lower cooling loads.

with varying visible light transmittances and tints.

Page 22: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Natural Ventilation Natural ventilation occurs when outdoor air is introduced to a space without the use of mechanical systems, such as a fan.

Most often, natural ventilation is assured though operable windows but it can also be achieved through temperature and pressure differences between spaces.

There are two types of natural ventilation for buildings: wind driven ventilation and stack ventilation.

The pressures generated by buoyancy, also known as "the stack effect," are quite low (typical values: 0.3 Pa to 3 Pa), while wind pressures are usually far greater (~1 Pa to 35 Pa).

Although the majority of buildings rely primarily on wind-driven ventilation, stack ventilation also has numerous benefits. The most efficient design for a natural ventilation building implements both types of ventilation.

To adequately ventilate a building using the stack effect, the inside and outside temperatures must be different so that warmer indoor air rises and escapes the building through higher apertures, while colder, denser air from the exterior enters the building through lower level openings.

The stack effect increases with greater temperature differences and increased height between the higher and lower apertures.

Page 23: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Natural Ventilation Rules of Thumb In order to adequately ventilate a building via the stack effect, the inside and outside temperatures must be different so that warmer indoor air can rise and escape the building at higher apertures, while colder, denser air from the exterior can enter the building through lower level openings

• Do not obstruct inlet and outlet openings with nearby objects. • Locate windows in opposing pressure zones since this usually will increase ventilation rate. • Keep enough vertical distance between apertures to produce stack effect. • Avoid multiple openings at the same level and near the ceiling or else much of the air flow may bypass

the occupied zone. • Use architectural elements like wing walls, parapets, and overhangs to promote air flow into the building. • Use topography, landscaping, and surrounding buildings to redirect airflow and give maximum exposure

to breezes. • Maximize air velocities in occupied zones to promote bodily cooling if you live in a hot, humid climate.• Orient the long façade of the building and the door and window openings with respect to the prevailing

wind direction to admit wind airflow. • Make window openings accessible to and operable by occupants if possible. • Use vertical shafts and open staircases to increase and generate stack effect. • Reduce the number of openings near the neutral pressure level because they are less effective for

thermally induced ventilation. • Ensure that all inlet and outlet openings are of nearly equal areas to obtain a balanced and greater

ventilation.

(“Air Movement and Natural Ventilation,” Dr. Sam C M Hui Department of Mechanical Engineering, The University of Hong Kong, http://www.arch.hku.hk/teaching/lectures/airvent/sect03.htm).

Page 24: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Compressorless CoolingIn Persia, during the Medieval era, builders created a natural cooling technique that is still in use today in modern Iran. Buildings were built over cisterns and capped with wind towers to cool subterranean rooms during the hot season. The cisterns are large, open, below-ground pools that are fed by subterranean water canals called qanats.

The air from the qanat is drawn into the tunnel at some distance away and is cooled both by contact with the cool tunnel walls and water, and by giving up latent heat as water evaporates into the air stream. In dry desert climates, this can result in a greater than 27°F/15°C reduction in the air temperature coming from the qanat.

This technology has been in use for over 1,000 years.

Left: Traditional cisterns with double domes and windcatchers in the central desert city of Naeen, near Yazd, Iran. Photo by Zereshk , 2005, Wikimedia Commons.

Creative Commons Attribution ShareAlike 3.0 License, http://creativecommons.org/licenses/by-sa/3.0/

Right: Windcatcher used for cooling in conjunction with qanat. Illustration based on concepts as discussed in article by Bahadori, M. N., "Passive Cooling Systems in

Iranian Architecture" Scientific American, February 1978, pp. 144-154,

Left: Traditional cisterns with double domes and windcatchers in the central desert city of Naeen, near Yazd, Iran. Photo by Zereshk , 2005, Wikimedia Commons.

Creative Commons Attribution ShareAlike 3.0 License, http://creativecommons.org/licenses/by-sa/3.0/

Right: Windcatcher used for cooling in conjunction with qanat. Illustration based on concepts as discussed in article by Bahadori, M. N., "Passive Cooling Systems in

Iranian Architecture" Scientific American, February 1978, pp. 144-154,

Page 25: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Compressorless CoolingOther non-mechanical approaches to air-cooling include:

Night sky cooling, which cools water by spraying it over a building roof at night. Once cooled, the water is collected from the roof, filtered, and stored. It can be used the following day to cool the building either in conventional water-cooled HVAC systems or by passive cooling of the roof or floor.

Evaporative coolers use water to cool air. Air blowing through a wet medium (a bathing suit, cellulose membranes, and so on) evaporates some of the water and its dry bulb temperature is lowered. The cooling effect of an evaporative cooler depends on two factors. The first is level of humidity (the difference between the air’s dry bulb and wet bulb temperatures); the second is the cooling device’s efficiency.

Evaporative coolers typically come in three general designs:

• Direct evaporative cooling. With direct evaporative cooling, outside air is blown through a water-saturated medium (usually cellulose) and cooled by evaporation. A blower circulates the cooled air. Direct evaporative cooling adds moisture to the air stream until the air stream is close to saturation. The dry bulb temperature is reduced, while the wet bulb temperature stays the same.

• Indirect evaporative cooling. With indirect evaporative cooling, a secondary (scavenger) air stream is cooled by water. The cooled secondary air stream goes through a heat exchanger, where it cools the primary air stream. A blower circulates the cooled primary air stream. Indirect evaporative cooling does not add moisture to the primary air stream. Both the dry bulb and wet bulb temperatures are reduced. During the heating season, an indirect system’s heat exchanger can preheat outside air if exhaust air is used as the secondary air stream.

• Indirect/direct evaporative (IDEC) cooling. With indirect/direct evaporative cooling, the primary air stream is cooled first with indirect evaporative cooling, and then cooled further with direct evaporative cooling.

Page 26: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Onsite Renewable EnergyElectrical energy can be generated from a variety of renewable sources that are available on the building site.

These sources can include:

• Solar photovoltaic power • Wind power• Micro-hydroelectric power • Tidal/wave power• Renewable biofuels

Photovoltaic solar panels on the roof of a house near Boston, Massachusetts, photo by Gray Watson, 2006, http://256.com/solar/, Wikimedia Commons, Creative Commons Attribution ShareAlike 3.0 License,

http://creativecommons.org/licenses/by-sa/3.0/

Photovoltaic solar panels on the roof of a house near Boston, Massachusetts, photo by Gray Watson, 2006, http://256.com/solar/, Wikimedia Commons, Creative Commons Attribution ShareAlike 3.0 License,

http://creativecommons.org/licenses/by-sa/3.0/

Regents Quarter development at Kings Cross, London, UK, with wind turbines on the roof, photo by Judith, London, UK, 2008, Wikimedia Commons, Creative Commons Attribution 2.0, http://creativecommons.org/licenses/by/2.0/

Regents Quarter development at Kings Cross, London, UK, with wind turbines on the roof, photo by Judith, London, UK, 2008, Wikimedia Commons, Creative Commons Attribution 2.0, http://creativecommons.org/licenses/by/2.0/

Voltage profile of an on site wind power turbine generator, Marco Ortiz, Juan Ríos, Manuel Acosta, “Wind Generation and Power System Interaction Analysis Using Probabilistic Techniques”, Electrical Systems Planning Division CVG EDELCA Caracas, Venezuela, "2008 International Conference on Renewable Energy and Power Quality (ICREPQ´08)," Santander, Spain, 2008, http://www.icrepq.com/icrepq-08/277-ortiz.pdf.

Voltage profile of an on site wind power turbine generator, Marco Ortiz, Juan Ríos, Manuel Acosta, “Wind Generation and Power System Interaction Analysis Using Probabilistic Techniques”, Electrical Systems Planning Division CVG EDELCA Caracas, Venezuela, "2008 International Conference on Renewable Energy and Power Quality (ICREPQ´08)," Santander, Spain, 2008, http://www.icrepq.com/icrepq-08/277-ortiz.pdf.

Page 27: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Summary

The design of the building envelope for carbon neutrality can be optimized through a variety of daylighting, passive solar heating and cooling, and natural ventilation techniques. The renewable energy producing potential of a building site can also be effectively modeled.

Page 28: © 2009 Autodesk Autodesk Sustainable Design Curriculum Lesson Five: Optimizing the Design of the Building Envelope for Sustainability  Carbon Neutrality.

© 2009 Autodesk

Autodesk, AutoCAD, Civil 3D, Ecotect, Green Building Studio and Revit are registered trademarks or trademarks of Autodesk, Inc. and/or its subsidiaries and/or affiliates, in the USA and/or other countries. All other brand names, product names, or trademarks belong to their respective holders. Autodesk reserves the right to alter product offerings and specifications at any time without notice, and is not responsible for typographical or graphical errors that may appear in this document.

© 2009 Autodesk, Inc. All rights reserved.


Recommended