METRIC 142 [5.6] OPTIONAL ISOLATOR SPRINGS 650 25.6 2850 112.2 925 36.4 1863 73.3 MLCB HEIGHT (NOTE 2) 616 24.2 HIGH VOLTAGE STUB-UP 60 2.4 A ALT AIR OUT ALT AIR OUT RADIATOR DRAIN (NOTE 3) FUEL FILTER PRIMARY CIRCUIT BREAKER OIL DRAIN (NOTE 3) 2042 80.4 EXHAUST OUTLET (NOTE 3) 141 5.5 RADIATOR CAP 369 14.5 RADIATOR CAP 396 15.6 RADIATOR CAP 1050 41.3 EXHAUST OUTLET (NOTE 3) OPTIONAL SECONDARY CIRCUIT BREAKER BATTERY LOCATION (NOTE 1) PRIMARY CIRCUIT BREAKER OPTIONAL BATTERY LOCATION (NOTE 1) PRIMARY BLOCK HEATER LOCATION SECONDARY BLOCK HEATER LOCATION 2098 82.6 BASE WIDTH 1049 [41.3] 170 6.7 1768 69.6 RAD. OPEN AREA (NOTE 4) 1810 71.3 RAD. OPEN AREA (NOTE 4) RADIATOR DRAIN (NOTE 3) 900 35.4 C/C MTG. HOLES 2006 79.0 C/C MTG. HOLES 2088 82.2 FLEX CONN. 1865 73.4 EXH. OUTLET 2389 94.0 4565 179.7 4X 127[5.0] LIFTING EYE AIR DISCHARGE SEE NOTE 9 DETAIL A SCALE 1 : 12 FUEL OUT FUEL IN 15.00° 533 21.0 476 18.8 B.C. 12X 1.12[28.6] THRU 222 8.8 SCALE 1:24 320 12.6 280 11.0 B.C. 8X 23[0.9] THRU ENGINE CONNECTION (JIS 200MM) NOTES: 1. BATTERY (24 VOLT GROUND SYSTEM) 2. MAIN LINE CIRCUIT BREAKER (MLCB), AC LOAD LEADS. (DIMENSIONS MAY VARY DUE TO UNIT CONFIGURATION) 3. ENGINE SERVICE CONNECTIONS: INLET DIESEL = 3/4" NPT RETURN DIESEL = 3/4" NPT OIL DRAIN = 3/4" NPT COUPLING RADIATOR DRAIN = 3/4" NPT FLEX PIPE OUTLET - 21" O.D. (14" ASA) EXHAUST OUTLET = 200MM (8IN) JIS FLANGE 4. GENERATOR SET MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND DISCHARGE AIR FROM THE RADIATOR IS NOT RECIRCULATED. 5. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION. 6. EXHAUST SYSTEM MAXIMUM BACK PRESSURE = 23" 7. OPTIONAL ISOLATOR SPRINGS INCREASES UNIT HEIGHT BY APPROXIMATELY 5.6" 8. CONNECT THE OPEN SET EXHAUST PER NFPA 37. 9. OPTIONAL ALTERNATORS: (480 V. 125 C TEMP. RISE ALTERNATOR SHOWN.) 10. ALL DIMENSIONS ARE IN MM [INCHES] INSTALLATION DRAWING EXHAUST CONNECTION (14 IN ASA) D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 SLS-SD-750-800-OP D C B A A B C D 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS. GENERAC POWER SYSTEMS 2013 000000858864 SD/MD/750/800 KW INSTALLATION DRAWING OPEN SET D33.9 SLS-SD-750-800-OP - - - - 1:48 SHEET WT-KG SCALE: B REV/VER DWG NO. CAGE NO. SIZE DRAWN BY: DATE APPROVAL PAINT SURFACE FINISH GENERAC MATL SPECIFICATION MATERIAL c INTERPRET DIM AND TOL PER ASME Y14.5M-1994 TITLE THIRD ANGLE PROJECTION GENERAL TOLERANCES UNLESS NOTED TDR: REF: MODEL NO: REV. DESC: 00 - 98.M2800-G1 12:42:56 12/02/2014 - PGMICG0 - 2 OF 1 -
Transcript

METRIC

142[5.6]

OPTIONALISOLATORSPRINGS

65025.6

2850112.2

92536.4

186373.3

MLCBHEIGHT

(NOTE 2)

61624.2

HIGH VOLTAGESTUB-UP

602.4

A

ALT AIROUT

ALT AIROUT

RADIATOR DRAIN(NOTE 3)

FUEL FILTER

PRIMARYCIRCUITBREAKER

OIL DRAIN(NOTE 3)

204280.4

EXHAUST OUTLET(NOTE 3)

1415.5

RADIATORCAP

36914.5

RADIATORCAP

39615.6

RADIATORCAP

105041.3

EXHAUST OUTLET(NOTE 3)

OPTIONALSECONDARYCIRCUITBREAKER

BATTERYLOCATION(NOTE 1)

PRIMARY CIRCUITBREAKER

OPTIONAL BATTERYLOCATION (NOTE 1)

PRIMARY BLOCKHEATER LOCATION

SECONDARYBLOCKHEATER

LOCATION

209882.6

BASE WIDTH

1049[41.3]

1706.7

176869.6RAD.

OPEN AREA(NOTE 4)

181071.3

RAD. OPEN AREA(NOTE 4)

RADIATORDRAIN

(NOTE 3)

90035.4

C/C MTG.HOLES

200679.0

C/C MTG. HOLES

208882.2FLEX

CONN. 186573.4EXH.

OUTLET

238994.0

4565179.7

4X 127[5.0]

LIFTING EYE

AIRDISCHARGE

SEENOTE 9

DETAIL ASCALE 1 : 12

FUELOUT

FUELIN

15.00°

53321.0

47618.8B.C.

12X 1.12[28.6]THRU

2228.8

SCALE 1:24

32012.6

28011.0B.C.

8X 23[0.9]THRU

ENGINECONNECTION(JIS 200MM)

NOTES:1. BATTERY (24 VOLT GROUND SYSTEM)2. MAIN LINE CIRCUIT BREAKER (MLCB), AC LOAD LEADS. (DIMENSIONS MAY VARY DUE TO UNIT CONFIGURATION)3. ENGINE SERVICE CONNECTIONS: INLET DIESEL = 3/4" NPT RETURN DIESEL = 3/4" NPT OIL DRAIN = 3/4" NPT COUPLING RADIATOR DRAIN = 3/4" NPT FLEX PIPE OUTLET - 21" O.D. (14" ASA) EXHAUST OUTLET = 200MM (8IN) JIS FLANGE4. GENERATOR SET MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND DISCHARGE AIR FROM THE RADIATOR IS NOT RECIRCULATED.5. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION.6. EXHAUST SYSTEM MAXIMUM BACK PRESSURE = 23"7. OPTIONAL ISOLATOR SPRINGS INCREASES UNIT HEIGHT BY APPROXIMATELY 5.6"8. CONNECT THE OPEN SET EXHAUST PER NFPA 37.9. OPTIONAL ALTERNATORS: (480 V. 125 C TEMP. RISE ALTERNATOR SHOWN.)10. ALL DIMENSIONS ARE IN MM [INCHES]

INSTALLATION DRAWING

EXHAUSTCONNECTION

(14 IN ASA)

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

SLS-SD

-750-800-OP

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS

WRITTEN CONSENT OF GENERAC POWER SYSTEMS.

GENERAC POWER SYSTEMS 2013

000000858864

SD/MD/750/800 KWINSTALLATION DRAWING OPEN SET D33.9

SLS-SD-750-800-OP

-- -

-1:48 SHEETWT-KGSCALE:B

REV/VERDWG NO.CAGE NO.SIZEDRAWN BY:

DATEAPPROVALPAINT SURFACE

FINISHGENERAC MATL SPECIFICATION

MATERIALc

INTERPRET DIM AND TOLPER ASME Y14.5M-1994

TITLE

THIRD ANGLE PROJECTIONGENERAL TOLERANCES UNLESS NOTED

TDR:REF:MODEL NO:REV. DESC:

00-

98.M2800-G1

12:42:56 12/02/2014

-

PGMICG0-

2OF1

-

METRIC

59723.5

1359

53.5

212183.5

2883113.5

3645143.5

209982.7

200679.0

MTG.HOLE

CENTERS

4565179.7

97438.4

90035.4

MTG.HOLE

CENTERS

100339.5

105041.3

45017.7

48719.2

522.0

152

6.0

71128.0

38115.0

25410.0

1526.0

199678.6

1526.0

903.5

29511.6

125749.5

143056.3

ELECTRICALSTUB-UP

AREA

OPTIONALSECONDARYSTUB-UPAREA

FUELSTUB-UP

AREA

10X 22[0.87] MTG HOLES

BATTERY RACKLOCATION

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

SLS-SD

-750-800-OP

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS

WRITTEN CONSENT OF GENERAC POWER SYSTEMS.

GENERAC POWER SYSTEMS 2013

000000858864

SD/MD/750/800 KWSTUB-UP INSTALLATION DRAWING OP D33.9

SLS-SD-750-800-OP

-- -

-1:16 SHEETWT-KGSCALE:B

REV/VERDWG NO.CAGE NO.SIZEDRAWN BY:

DATEAPPROVALPAINT SURFACE

FINISHGENERAC MATL SPECIFICATION

MATERIALc

INTERPRET DIM AND TOLPER ASME Y14.5M-1994

TITLE

THIRD ANGLE PROJECTIONGENERAL TOLERANCES UNLESS NOTED

TDR:REF:MODEL NO:REV. DESC:

1-

98.M2800-G1

12:42:56 12/02/2014

A

PGMICG0-

2OF2

-

METRIC

ZY

X

CGREFERENCE POINT(0,0,0)(NO TANK OPTION)

STANDARDENCLOSUREOUTLINE

CGREFERENCE POINT(0,0,0)(TANK OPTION)

PRIMARYCIRCUITBREAKER

INSTALLATION DRAWING

LO ENCLOSURE, STEEL

OPEN UNIT

LO ENCLOSURE, ALUMINUM

L2 ENCLOSURE, ALUMINUML2 ENCLOSURE, STEEL

L1 ENCLOSURE, STEEL L1 ENCLOSURE, ALUMINUM

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 10204 22496 2316 [91.2"] 1102 [43.4"] 835 [32.9"] NO TANK11996 26446 2391 [94.1"] 1189 [46.9"] 1110 [43.7"] 12 HR TANK12620 27822 2399 [94.4"] 1190 [46.9"] 1365 [53.7"] 24 HR TANK

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 12723 28049 2347 [92.4"] 1191 [46.9"] 1221 [48.1"] NO TANK13644 30078 2361 [93.0"] 1193 [47.0"] 1267 [49.9"] 12 HR TANK14268 31454 2370 [93.3"] 1194 [47.0"] 1524 [60.0"] 24 HR TANK

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 12198 26890 2339 [92.1"] 1189 [46.8"] 1201 [47.3"] NO TANK13118 28919 2354 [92.7"] 1192 [46.9"] 1246 [49.1"] 12 HR TANK13742 30295 2363 [93.0"] 1193 [47.0"] 1500 [59.1"] 24 HR TANK

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 14268 31454 2604 [102.5"] 1193 [47.0"] 1243 [48.9"] NO TANK14999 33067 2677 [105.4"] 1195 [47.0"] 1164 [45.8"] 12 HR TANK15521 34217 2709 [106.6"] 1196 [47.1"] 1339 [52.7"] 24 HR TANK

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 13742 30295 2521 [99.3"] 1191 [46.9"] 1208 [47.6] NO TANK13955 30764 2607 [102.6"] 1193 [47.0"] 1126 [44.3"] 12 HR TANK14476 31914 2643 [104.1"] 1194 [47.0"] 1299 [51.1"] 24 HR TANK

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 14803 32633 2665 [104.9"] 1195 [47.0"] 1339 [50.0"] NO TANK16052 35388 2739 [107.8"] 1197 [47.1"] 1198 [47.2"] 12 HR TANK16574 36538 2767 [108.9"] 1197 [47.1"] 1375 [54.1"] 24 HR TANK

UNIT VOLTAGE WEIGHT (KG) WEIGHT (LBS) CofG DIM X CofG DIM Y CofG DIM Z TANK OPTION

SD800 208/480/600V 13313 29349 2558 [100.7"] 1192 [46.9"] 1299 [48.2"] NO TANK14481 31924 2643 [104.1"] 1194 [47.0"] 1146 [45.1"] 12 HR TANK15003 33074 2677 [105.4"] 1195 [47.0"] 1320 [52.0"] 24 HR TANK

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

SLS-SD

-800-CG

D

C

B

AA

B

C

D

12345678

8 7 6 5 4 3 2 1

GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT THE EXPRESS

WRITTEN CONSENT OF GENERAC POWER SYSTEMS.

GENERAC POWER SYSTEMS 2013

--

SD/MD/750/800KWINSTALLATION DRAWING CG D33.9

SLS-SD-800-CG

-- -

-1:75 SHEETWT-KGSCALE:B

REV/VERDWG NO.CAGE NO.SIZEDRAWN BY:

DATEAPPROVALPAINT SURFACE

FINISHGENERAC MATL SPECIFICATION

MATERIALc

INTERPRET DIM AND TOLPER ASME Y14.5M-1994

TITLE

THIRD ANGLE PROJECTIONGENERAL TOLERANCES UNLESS NOTED

ECO:REF:MODEL NO:REV. DESC:

1-

98.M2800-G1

4/17/2015

A

MRADEMACINITIAL RELEASE

1OF1

-

pcurry
Rectangle

R

MH18481 MH46743 MH25279File Numbers:

LUR

Underwriters

LISTED

Laboratories, Inc.

AutoCAD SHX Text
%%UTOP
AutoCAD SHX Text
%%uSIDE
AutoCAD SHX Text
%%uEND
AutoCAD SHX Text
%%URADIATOR END
AutoCAD SHX Text
SLS-SD-750-800-OP RCK 081215
AutoCAD SHX Text
SLS-SD-750-800-OP RCK 081215
AutoCAD SHX Text
SLS-SD-750-800-OP RCK 081215
AutoCAD SHX Text
SLS-SD-750-800-OP RCK 081215
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
CALDYN RJSD-7855
AutoCAD SHX Text
L POWER COMPONENTS
AutoCAD SHX Text
BY
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
CHANGE MADE
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
1-1
AutoCAD SHX Text
X
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
9/21/2015
AutoCAD SHX Text
RCK
AutoCAD SHX Text
X LBS
AutoCAD SHX Text
TANK WEIGHT
AutoCAD SHX Text
GENSET MODEL
AutoCAD SHX Text
500 GAL
AutoCAD SHX Text
TANK CAPACITY
AutoCAD SHX Text
SD750 OPU
AutoCAD SHX Text
AAAQ20147
AutoCAD SHX Text
QUOTE #
AutoCAD SHX Text
179.7" X 82.7"
AutoCAD SHX Text
GENSET FOOTPRINT
AutoCAD SHX Text
GEN TECH
AutoCAD SHX Text
ALOFT HOTEL AUSTIN
AutoCAD SHX Text
JOB REF:
AutoCAD SHX Text
CUSTOMER/ID:
AutoCAD SHX Text
CHANGE MADE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
THIS AUTOCAD DRAWING IS THE PROPERTY OF GLOBAL POWER COMPONENTS AND MAY NOT BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF G.P.C. ANY MANUAL CHANGES WILL VOID THIS DRAWING. SPECIFICATIONS MAY CHANGE WITHOUT NOTICE.
AutoCAD SHX Text
SUB BASE TANK W/ RUPTURE BASIN & STUB UP
AutoCAD SHX Text
DRAWING REF:
AutoCAD SHX Text
DWG #:
AutoCAD SHX Text
AAAQ20147
AutoCAD SHX Text
PRELIMINARY DRAWING
pcurry
Rectangle

R

MH18481 MH46743 MH25279File Numbers:

LUR

Underwriters

LISTED

Laboratories, Inc.

AutoCAD SHX Text
%%UTOP
AutoCAD SHX Text
%%uSIDE
AutoCAD SHX Text
%%uEND
AutoCAD SHX Text
%%URADIATOR END
AutoCAD SHX Text
10X 1516" HOLE BOTTOM
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
Z
AutoCAD SHX Text
S
AutoCAD SHX Text
40X 1516"X1 " SLOT 12" SLOT SUPPORT PLATE
AutoCAD SHX Text
X
AutoCAD SHX Text
Y
AutoCAD SHX Text
G
AutoCAD SHX Text
F
AutoCAD SHX Text
V
AutoCAD SHX Text
H
AutoCAD SHX Text
ISOLATOR PAD SUPPORT PLATE CALDYN RJSD-7855 MAT'L: " STEEL QTY: 1014" STEEL QTY: 10
AutoCAD SHX Text
L POWER COMPONENTS
AutoCAD SHX Text
BY
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
CHANGE MADE
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
QTY
AutoCAD SHX Text
2
AutoCAD SHX Text
PART #
AutoCAD SHX Text
3164
AutoCAD SHX Text
V
AutoCAD SHX Text
U
AutoCAD SHX Text
T
AutoCAD SHX Text
LETTER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BILL OF MATERIAL
AutoCAD SHX Text
FLANGE, 4", EMERGENCY VENT
AutoCAD SHX Text
1-1
AutoCAD SHX Text
X
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
9/21/2015
AutoCAD SHX Text
RCK
AutoCAD SHX Text
X LBS
AutoCAD SHX Text
TANK WEIGHT
AutoCAD SHX Text
GENSET MODEL
AutoCAD SHX Text
500 GAL
AutoCAD SHX Text
TANK CAPACITY
AutoCAD SHX Text
SD750 OPU
AutoCAD SHX Text
AAAQ20147
AutoCAD SHX Text
QUOTE #
AutoCAD SHX Text
179.7" X 82.7"
AutoCAD SHX Text
GENSET FOOTPRINT
AutoCAD SHX Text
GEN TECH
AutoCAD SHX Text
ALOFT HOTEL AUSTIN
AutoCAD SHX Text
JOB REF:
AutoCAD SHX Text
CUSTOMER/ID:
AutoCAD SHX Text
CHANGE MADE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
THIS AUTOCAD DRAWING IS THE PROPERTY OF GLOBAL POWER COMPONENTS AND MAY NOT BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF G.P.C. ANY MANUAL CHANGES WILL VOID THIS DRAWING. SPECIFICATIONS MAY CHANGE WITHOUT NOTICE.
AutoCAD SHX Text
SUB BASE TANK W/ RUPTURE BASIN & STUB UP
AutoCAD SHX Text
DRAWING REF:
AutoCAD SHX Text
DWG #:
AutoCAD SHX Text
3655
AutoCAD SHX Text
3655
AutoCAD SHX Text
AAAQ20147
AutoCAD SHX Text
FLANGE, 2", SUPPLY, W/ 3/4" DIP TUBE
AutoCAD SHX Text
1
AutoCAD SHX Text
1000
AutoCAD SHX Text
FLANGE, 2", RETURN, W/ 3/4" DIP TUBE
AutoCAD SHX Text
PRELIMINARY DRAWING
AutoCAD SHX Text
S
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1003
AutoCAD SHX Text
4306
AutoCAD SHX Text
3152
AutoCAD SHX Text
Y
AutoCAD SHX Text
FUEL IN BASIN ALARM
AutoCAD SHX Text
FLANGE, 2", STANDARD VENT CAP
AutoCAD SHX Text
3502
AutoCAD SHX Text
FLANGE, 1/2", BASIN DRAIN
AutoCAD SHX Text
1
AutoCAD SHX Text
8410
AutoCAD SHX Text
FLUSH MOUNT LIFTING PLATE
AutoCAD SHX Text
4
AutoCAD SHX Text
FLANGE, 2", FUEL LEVEL GAUGE
AutoCAD SHX Text
8003
AutoCAD SHX Text
REMOVABLE END PLATE - 3" BEND
AutoCAD SHX Text
1
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
34" STANDARD ELECTRICAL STUB UP
AutoCAD SHX Text
4000
AutoCAD SHX Text
1
AutoCAD SHX Text
3005
AutoCAD SHX Text
FLANGE, 2", LOCKING FILL PORT
AutoCAD SHX Text
1
AutoCAD SHX Text
H. COUPLING, 2", LOW LEVEL ALARM @50%%%
AutoCAD SHX Text
DW-101
AutoCAD SHX Text
DOUBLE WALL SECONDARY CONTAINMENT
AutoCAD SHX Text
PAINT COLOR
AutoCAD SHX Text
GLOSS BLACK (9638)
AutoCAD SHX Text
G
AutoCAD SHX Text
FLANGE, 2", EXTRA FITTING W/ PLUG
AutoCAD SHX Text
3195
AutoCAD SHX Text
4
AutoCAD SHX Text
6" I-BEAM GENSET SUPPORT
AutoCAD SHX Text
8303
AutoCAD SHX Text
5
AutoCAD SHX Text
8420
AutoCAD SHX Text
10
AutoCAD SHX Text
ISOLATOR PAD SUPPORT PLATE
AutoCAD SHX Text
X
AutoCAD SHX Text
Z
AutoCAD SHX Text
F
AutoCAD SHX Text
FLANGE, 2", 2" x 1-1/4" TAPPED BUSHING
AutoCAD SHX Text
1006
AutoCAD SHX Text
1
AutoCAD SHX Text
(GENERAC SENDER)
AutoCAD SHX Text
1
AutoCAD SHX Text
H
AutoCAD SHX Text
FLANGE, 2", EXTRA FITTING W/ PLUG
AutoCAD SHX Text
3195
AutoCAD SHX Text
1
AutoCAD SHX Text
(4-20MA SENDER)
AutoCAD SHX Text
1

ULR

UnderwritersLaboratories, Inc. Listed

R

MH18481FILE NO. MH46743

MH25279

6682 W. GREENFIELD AVEWEST ALLIS, WI 53214

PH (414)475-3000 FAX (414) 475-3441

www.globalpowercomponents.com

GLOBAL POWER COMPONENTS

68

3FLANGE

14 14 25.5

65 1.5

END

L

9

21.5

32 0

33

23

58

53

48

43

38

28

16

6

0 5

12

18

26

34

53 58 9

S

YUV T

X

TOP

A

Z

H

B RAD

IATO

R EN

D

F

G

K

J

H

2X 1/2" X 1.125"WELD STUD

42

5TYP

9

68 17.5

28.5

5612

2

C

SIDE

4X 1516" HOLEBOTTOM

REVISIONSREV. DESCRIPTION DATE BY

BILL OF MATERIALS

ITEM PART NUMBER DESCRIPTION QTY.

S 3165 FLANGE, 5", EMERGENCY VENT 2T 3650R FLANGE, 2", FUEL RETURN W/ 1/2" DIP TUBE 1U 3650S FLANGE, 2", FUEL SUPPLY W/ 1/2" DIP TUBE 1V 1000 FLANGE, 2", LOW LEVEL ALARM (SET AT 21") 1X 1001 FLANGE, 2", KRUEGER FUEL GAUGE (SET AT 39") 1Y 3152 FLANGE, 2", STANDARD VENT CAP 1Z 3005 FLANGE, 2", LOCKING FILL PORT 1A 4300 FLANGE, 2", FUEL IN BASIN ALARM (TOP MOUNT) 1B 3502 FLANGE, 1/2", BASIN DRAIN 1C 8410 1/4" FLUSH MOUNT LIFTING PLATE 4

F1010 FLANGE, 2", HIGH LEVEL ALARM (SET AT 4-3/4") 11020 CRITICAL HIGH LEVEL ALARM (SET AT 2-3/4") 1

G 3600 FLANGE, 2", 1/2" DIP TUBE 1H 3195 FLANGE, 2", EXTRA FITTING W/ PLUG 4J 3191 FLANGE, 1/2", EXTRA FITTING W/ PLUG 1K 4306 FUEL IN BASIN ALARM 1L 3185 FULL COUPLING, 2", EXTRA FITTING (PUMP CONTAINMENT) 2

1380 SERIES 400 CONTROLLER SINGLE W/ REVERSE 12025 SINGLE PUMP SYSTEM 1

6040

1/3 HP CARBONATE MOTOR, SINGLE PHASE1

115/208-230V, 50/60Hz, 48YZ FRAMEBRONZE CLOSE COUPLED 4 GPM

1ROTARY GEAR PUMP, 3/8" PORTS

SPECIAL PUMP CONTAINMENT BOX W/ PUMP BASE 1700-1025 1/2" FUEL STRAINER, Y-STYLE (SHIP LOOSE) 1700-1096 1/2" SOLENOID VALVE (120VAC, NC) (SHIP LOOSE) 1700-1065 1/2" SPRING CHECK VALVE (SHIP LOOSE) 1

1055-AFP4STEEL REMOTE ALARM FILL STATION (FLUSH MOUNT) 1

REMOTE FOUR ALARM FILL PANEL W/ RELAYS 1SPECIAL MORRISON DRY DISCONNECT ADAPTOR (927-0200A, 2") 1SPECIAL MORRISON DUST CAP (735DC-2500ACEVR) 1700-1055 2" BALL VALVE 1700-1080 2" SPRING CHECK VALVE 1700-1118 2" SOLENOID VALVE (120VDC, NO) 1

DW-101 DOUBLE WALL SECONDARY CONTAINMENTPAINT COLOR GLOSS BLACK (9638)

JOB # TANK CAPACITY ACTUAL GENSET MODELTANK WEIGHTAPPROVED BY: DATE:26510 518 GAL X 1800 LBS

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFGLOBAL POWER COMPONENTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT

THE WRITTEN PERMISSION OF GLOBAL POWER COMPONENTS IS PROHIBITED.

TANK CAPACITY USEABLE

500 GALGENSET FOOTPRINT

X

15-26510B

DESCRIPTION

SHEET 2 OF 6

DWG. NO.SIZE

SCALE: 1:24

FREESTANDING TANK WITH RUPTURE BASIN

DRAWING REFERENCE:

JOB REFERENCE:

CUSTOMER NAME:

X

LE MERIDEN AC HOTEL MARRIOTT

GEN TECH 8/18/2016

RCK

DATE

DRAWN BY

THIRD ANGLE PROJECTION

REV. ± .1± .06± 2°± .005

.X.XX

THE TOLERANCES ARE:

ONE PLACETWO PLACEANGLEHOLE DIA.

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES

ULR

UnderwritersLaboratories, Inc. Listed

R

MH18481FILE NO. MH46743

MH25279

6682 W. GREENFIELD AVEWEST ALLIS, WI 53214

PH (414)475-3000 FAX (414) 475-3441

www.globalpowercomponents.com

GLOBAL POWER COMPONENTS

ISO VIEW

15-26510B

DESCRIPTION

SHEET 3 OF 6

DWG. NO.SIZE

SCALE: 1:10

JOB # APPROVED BY: DATE:26510

FREESTANDING TANK WITH RUPTURE BASINISO VIEW

DRAWING REFERENCE:

JOB REFERENCE:

CUSTOMER NAME:

X

LE MERIDEN AC HOTEL MARRIOTT

GEN TECH 8/18/2016

RCK

DATE

DRAWN BY

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFGLOBAL POWER COMPONENTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT

THE WRITTEN PERMISSION OF GLOBAL POWER COMPONENTS IS PROHIBITED.

REV.

THIRD ANGLE PROJECTION

± .1± .06± 2°± .005

.X.XX

THE TOLERANCES ARE:

ONE PLACETWO PLACEANGLEHOLE DIA.

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES

ULR

UnderwritersLaboratories, Inc. Listed

R

MH18481FILE NO. MH46743

MH25279

6682 W. GREENFIELD AVEWEST ALLIS, WI 53214

PH (414)475-3000 FAX (414) 475-3441

www.globalpowercomponents.com

GLOBAL POWER COMPONENTS

12

2

30

24

8 1TYP

A

5

4TYP

4TYP

2X 2" FULL COUPLING

1.38TYP

4.25TYP

2.13TYP

2.75TYP

DETAIL ASCALE 1 : 4

4X 1/4" X 1-1/4" SLOTS

NOTE:WELD 2" FULL COUPLINGS HALF WAY THROUGH

15-26510BSHEET 6 OF 6

DWG. NO.SIZE

SCALE: 1:8

JOB # APPROVED BY: DATE:26510

PUMP BOX

DRAWING REFERENCE:

JOB REFERENCE:

CUSTOMER NAME:

X

LE MERIDEN AC HOTEL MARRIOTT

GEN TECH 8/18/2016

RCK

DATE

DRAWN BY

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFGLOBAL POWER COMPONENTS. ANY REPRODUCTION IN PART OR WHOLE WITHOUT

THE WRITTEN PERMISSION OF GLOBAL POWER COMPONENTS IS PROHIBITED.

REV.

THIRD ANGLE PROJECTION

± .1± .06± 2°± .005

.X.XX

THE TOLERANCES ARE:

ONE PLACETWO PLACEANGLEHOLE DIA.

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHES

DESCRIPTION

Low Voltage Customer Connections Panel

AU

X C

ontacts

N.C.

N.O.

COM

178 (0)

183

Automatic Transfer Switch

Utility P

ow

er S

upply

240 V

AC

, 30 A

mp

TB1

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

RS485+

RS485-

SHLD

178 (0)

183

Common

D 14 (N.O.)

D 13 (N.C.)

B+

B-

TB2

TB4

1

2

3

4

5

6

7

8

9

10

11

12

13

14

L1

Neutral

L2

GN

D

Located in High Voltage Customer Connection Module

BLK

WHT

BLK

GRN

Provides AC power for AC powered Accessories

21 Light Remote

Annunciator Panel

Ext Alarm Com

Ext. Alarm N/O

Screen

SHLD

Battery -

Battery + (12V/24V)

RS485 -

RS485 +

TB1-9

TB1-11

TB1-8

E-STOP

TB1 - E-STOP

TB1 - E-STOP

REMOTE EMERGENCY STOP

1

2

E-STOP

E-STOP

#14 Ga. Stranded Wire

#14 Ga. Stranded Wire

#14 Ga. Stranded Wire

Single twisted pair, 16 ga., shielded (RS485)

#14 Ga. Stranded Wire

GENERAC CONTROL WIRING DIAGRAM

N.O.

COM

Ele

va

to

r

Co

nta

cts

Pre

-S

ig

na

l

Co

nta

cts

#14 Ga. Stranded Wire

#14 Ga. Stranded Wire

ELEVATOR CONTROLLER

Ele

va

to

r

Co

nta

cts

Pre

-S

ig

na

l

Co

nta

cts

REMOTE GENERATOR START SWITCH

RSC-178 (0)

RSC-183

#14 Ga. Stranded Wire

SPARE OUTPUT RELAY

1

2

3

4

5

6

7

8

9

10

11

12

AU

X 1

Customer Connection Cabinet

Programable output relays

NO

NC

COM

AU

X 2

NO

NC

COM

AU

X 3

NO

NC

COM

AU

X 4

NO

NC

COM

Rem

ote S

tart

Rem

ote S

tart

#14 Ga. Stranded Wire

#14 Ga. Stranded Wire

#14 Ga. Stranded Wire

Single twisted pair, 16 ga., shielded (RS485)

AU

X C

ontacts

N.C.

N.O.

COM

178 (0)

183

Automatic Transfer Switch

#14 Ga. Stranded Wire

N.O.

COM

Ele

va

to

r

Co

nta

cts

Pre

-S

ig

na

l

Co

nta

cts

Rem

ote S

tart

RS485+

RS485-

SHLD

Single twisted pair, 16 ga., shielded (RS485)

RS485+

RS485-

SHLD

Single twisted pair, 16 ga., shielded (RS485)

Transfer Switch

Annunciator Panel

Screen

SHLD

Battery -

Battery + (12V/24V)

RS485 -

RS485 +

Single twisted pair, 16 ga., shielded (RS485)

#14 Ga. Stranded Wire

AU

X C

ontacts

N.C.

N.O.

COM

178 (0)

183

Automatic Transfer Switch

N.O.

COM

Ele

va

to

r

Co

nta

cts

Pre

-S

ig

na

l

Co

nta

cts

Rem

ote S

tart

RS485+

RS485-

SHLD

Single twisted pair, 16 ga., shielded (RS485)

AU

X C

ontacts

N.C.

N.O.

COM

178 (0)

183

Automatic Transfer Switch

N.O.

COM

Ele

va

to

r

Co

nta

cts

Pre

-S

ig

na

l

Co

nta

cts

Rem

ote S

tart

RS485+

RS485-

SHLD

Single twisted pair, 16 ga., shielded (RS485)

S2653

Le Meridien

AC Hotel Marriott

Generac SD 750 Generator Set

Wiring

2.01/10/2016

NTS

Wiring

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

Remote Start Circuit

ATS#4

Generator Controller Remote Start Circuit

Transfer Switch Control Conduit (Auto Start - ATS Control ) - #14ga Wire

Remote Annunciator Panel Remote Start Circuit

ATS#3

ATS#FP

For Reference Only, refer to Submittal Drawing for Additional Information

ATS#2ATS#1

2.29/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

La Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Transfer Switch Switch Position

ATS-#2 (Critical)

Elevator Controller

Controller

Transfer Switch Control Conduit(Position and Pre Transfer Signal - Elevator Control ) - Qty 4 - #14ga

ATS-#2 (Critical)

Controller

Transfer Switch Elevator Pre-Signal Switch Elevator Controller

For Reference Only, refer to Submittal Drawing for Additional Information

2.39/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Master Remote Annunciator

RS-485 Communication (Mater Controller)

Annunciator

24 VDC Power (Mater Controller)

Generator Controller

Remote Annunicator Panel Control Conduit (Communication and Power )Qty 2 - #14ga DC Power,Qty 1 - RS-485 Communication

For Reference Only, refer to Submittal Drawing for Additional Information

Master Remote Annunciator

Annunciator

Generator Remote Annunciator Panel

Engineer's OfficeFire Command

Generator Remote Annunciator Panel

2.49/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Remote Stop Panel

Remote Emergency Stop Station

Remote Stop

Generator Controller

Generator Remote Stop StationQty 2 - #14ga control wire

For Reference Only, refer to Submittal Drawing for Additional Information

2.59/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Transfer Switch

Transfer Switch Control Conduit (Transfer Switch Indication - ATS Control ) - Qty 4 - #14ga for each ats

For Reference Only, refer to Submittal Drawing for Additional Information

ATS #1 - 4 Display Panel

ATS Remote Annunciator Panel

Transfer Switch Control Conduit (Transfer Switch Communication - ATS Control ) - Qty 1 - #RS-485, Qty 1 - 18ga Shielded Twisted Pair

ATS #1 - 4 Display Panel

ATS Remote Annunciator Panel

Engineer's OfficeFire Command

ATS # 4 ATS # 3 ATS # 2 ATS # 1

2.69/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Level Indication Sender

Remote Fill Station Panel Generator Fuel Tank - Fuel Tank Sender ( Communication)

Generator Set Remote Fill Station Control ConduitQty 1- Wire Control wires fuel Level Sender (RS-485)Qty 8 - #14ga Wire Control wires Fuel Level Full, High, and Critical High)Qty 2 - 120/208vac Power (control power (emergency))

120/208vac Power

Emergency Power 120/208 vac Panel

For Reference Only, refer to Submittal Drawing for Additional Information

Level Indication Sender

Full Indication Sender

Critical High Indication Sender

High Indication Sender

Full Indication Sender

Critical High Indication Sender

High Indication Sender

2.79/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Fire Alarm Control Panel

Generator Set and ATS Status

Fire Alarm Control PanelQty 2 - Control wire for Generator StatusQty 2 - Control wire for ATS Status

Generator Status - Run

Generator Set Status - Run Relay

ATS Status - Emergency

Automatic Transfer Switch ATS Status

For Reference Only, refer to Submittal Drawing for Additional Information

2.89/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout

Controller

Louver Control / Generator Air Supply

Run Relay

Generator Controller

Generator Louver ControlQty 2 - Control Wiring for Lovuver operation

For Reference Only, refer to Submittal Drawing for Additional Information

2.99/25/2015

NTS

Pad Layout

Arizona Generator Technology

7901 North 70th Avenue

Glendale, Arizona 85303

-

GEN-TECH POWER GENERATION SPECIALISTS

S2653

Le Meridien

AC Hotel Marriott

Generator Set

Wiring and Conduit Layout


Recommended