MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
ECCO Supply™ www.eccosupply.ca 2-1
Expert Service. Quality Products. Since 1960.
This section contains product information only. For additional information and product pricing please contact your local ECCO Supply™ Sales Branch.
For Technical & Warranty information see www.magic-pak.com
INDEXINTRODUCTION ................................................................................................................................................................ 2-2M-SERIES PACKAGED THRU-THE-WALL UNITS
MCE4 — ELECTRIC HEATING / ELECTRIC COOLING ..................................................................................... 2-3MHP4 — ELECTRIC HEAT PUMP ........................................................................................................................... 2-4
V-SERIES PACKAGED THRU-THE-WALL UNITSEWC — ELECTRIC HEATING / ELECTRIC COOLING ....................................................................................... 2-6HWC — GAS HEATING / ELECTRIC COOLING ................................................................................................. 2-5
WALL SLEEVES ................................................................................................................................................................... 2-7
MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –
ECCO Supply™2-2 www.eccosupply.ca
YEAR-ROUND COMFORT CONTROL... IN ONE COMPLETE PACKAGEDesigned by and for Architects, Engineers, Developers, Constructors
Conventional Split System Installation Requirements Thru-the-Wall Magic-Pak... Easy Installation 1. Uncrate and set furnace. Uncrate and set unit.2. Uncrate and set condensing unit. No!3. Uncrate and erect cooling coil plenum. No!4. Uncrate and set cooling coil. No!5. Run refrigerant lines. No!6. Connect, purge and evacuate refrigerant lines. No!7. Provide “B” vent from unit through roof (gas furnace installation). No!8. Provide roof jack and flashing for gas vent. No!9. Provide combustion air supply. No!10. Cut return air opening into furnace casing. No! It’s provided.11. Cut supply opening into coil plenum. No! It’s provided.12. Provide gas line and connect it at furnace location. Yes. (Gas / Electric only)13. Provide a condensate drain at furnace location. Yes.14. Provide drain line from cooling coil to condensate drain. Drain line included with unit.15. Provide power wiring from panel to condensing unit, 1 phase, 230V, 60 Hz. No!16. Provide weatherproof disconnect at condensing unit. No!17. Provide power connection into furnace, 1 phase, 120V, 60 Hz. Provide 1 phase, 230V, 60 Hz18. Provide low voltage connection from furnace to thermostat. Yes.19. Provide low voltage control wiring from furnace to condensing unit. No!20. Provide pad for condensing unit. No!TOTAL: 20 TIME-CONSUMING STEPS TOTAL: 5 TIME-SAVING STEPS
Magic-Pak Comfort Control AdvantagesCompletely self-contained heating and cooling package: • No outside condenser • No external refrigerant lines • No separate cooling coil • No chimney or external flue
Features• Pre-wired and pre-charged• Low operating sound levels• Easy to install• Low installation and operating costs• GAMA and AHRI performance certified• Design certified direct vent appliance• Many different louver styles and colours available• 5-year limited warranty – parts
COMPARE WHAT YOU DON'T GET WITH MAGIC-PAKWhat you don’t get with Magic-Pak Thru-The-Wall combination units can save you time and expense as a builder or contractor.You actually eliminate 15 installation steps, and the time it takes to perform them. Time is money, and you will save both when you choose Magic-Pak products for your project.
You also eliminate unsightly vents, stacks and condensing units. Building lines remain as clean and uncluttered as they appeared on the architect’s rendering or model.Discover the difference in heating and cooling convenience for yourself. Pick Magic-Pak Thru-The-Wall Combination Heating ⁄ Cooling Units.
MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –
ECCO Supply™ www.eccosupply.ca 2-3
Features• Up to 10.4 EER cooling efficiency• Completely self-contained heating and cooling package • No outside condensing unit • No external refrigerant lines • No separate cooling coil• Pre-wired and pre-charged• Individually metered and controlled• Easy service access• Louver colour options to match building façade• Available with optional factory-installed ventilation air kit• Available with no electric heat
Refrigerant System• R410a refrigerant• High efficiency compressor• Copper tubing with enhanced fin coils
Cabinet• Fully insulated cabinet for quiet operation• Anti-microbial insulation in all air handling compartments
Blower• Four-speed permanently lubricated motor for low
maintenance, maximum efficiency and wide airflow range• PSC permanently lubricated motor for low maintenance
and maximum efficiency• Dynamically balanced blower with resilient motor mounts
for smooth and quiet operation• Internal washable filter
Controls• Colour-coded wiring for easy service• Fuse protection on 24V circuit• No heat models include 24V output to control external
heat source
Installation• Easy to install and service• Louver mounts flush to outside wall
M-SERIES PACKAGED THRU-THE-WALL UNITSMCE4 — ELECTRIC HEATING / ELECTRIC COOLINGElectric kW range of 3–10 kW and BTUH cooling range of 12,000–35,000
MODEL NUMBER GUIDE
Revision Code
P = 208/230v/60hz/1
L = Factory Installed Ventilation Kit
Series
NOMINAL COOLING CAPACITY12 - 12,000 Btuh 18 - 18,000 Btuh 24 - 24,000 Btuh 30 - 30,000 Btuh
kW - 0, 3, 5, 7, 10
M = Magic-Pak
CE = Coolin/Electric
4 = R410a Refrigerant
09 - Standard Efficiency10 - High Efficiency
3 M CE 4 09 18 1 F - P 1Model Number Guide
MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –
ECCO Supply™2-4 www.eccosupply.ca
Features• Up to 10.0 EER cooling efficiency• Completely self-contained heating and cooling package • No outside condensing unit • No external refrigerant lines • No separate cooling coil• Pre-wired and pre-charged• Individually metered and controlled• Easy service access• Louver colour options to match building façade• Available with optional factory-installed ventilation air kit
Refrigerant System• R410a refrigerant• High efficiency compressor• Copper tubing with enhanced fin coils
Cabinet• Fully insulated cabinet for quiet operation• Anti-microbial insulation in all air handling compartments
Blower• Four-speed permanently lubricated motor for low
maintenance, maximum efficiency and wide airflow range• PSC permanently lubricated motor for low maintenance
and maximum efficiency• Dynamically balanced blower with resilient motor mounts
for smooth and quiet operation• Internal washable filter
Controls• Colour-coded wiring for easy service• Fuse protection on 24V circuit
Installation• Easy to install and service• Louver mounts flush to outside wall
M-SERIES PACKAGED THRU-THE-WALL UNITS (cont’d)MHP4 — ELECTRIC HEAT PUMPA COP of 3.0, BTUH cooling range of 12,000–34,800 and BTUH heating range of 11,000 – 34,600
Revision Code
P = 208/230v/60hz/1
F = Factory Installed Ventilation Kit
Series
NOMINAL COOLING CAPACITY12 - 12,000 Btuh 18 - 18,000 Btuh 24 - 24,000 Btuh 30 - 30,000 Btuh 36 - 30,000 Btuh
kW - 0, 3, 5, 7, 10
M = Magic-Pak
HP= Coolin/Electric
4 = R410a Refrigerant
09 - Standard Efficiency10 - High Efficiency
3 M HP 4 09 18 1 F - P 1
Model Number Guide
MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –
ECCO Supply™ www.eccosupply.ca 2-5
Features• High efficiency heating and cooling• Completely self-contained heating and cooling package • Microban® anti-microbial drain pan • No outside condensing unit • No external refrigerant lines • No separate cooling coil • No separate venting system• Pre-wired and pre-charged• Individually metered and controlled• Self-contained, replaceable, slide-out cooling chassis• Internal vent system (direct vent)• Freeze Shield™ condensate trap* with side or front
condensate connection**Patent Pending
Refrigerant System• High efficiency compressor• Copper tubing with enhanced fin coils
Heat Exchanger• Stainless steel primary and secondary heat exchanger and
transition box standard on high efficiency models
Blower• Multispeed motor for wide airflow range• ECM blower motor in high efficiency units• Dynamically balanced blower with resilient motor mounts
for smooth and quiet operation• Internal filter, optional MERV8
Controls• Colour-coded wiring for easy service• Diagnostic LED
Installation• Plug & Play like features
V-SERIES PACKAGED THRU-THE-WALL UNITSHWC — GAS HEATING / ELECTRIC COOLINGGas input heat capacity of 22,000 – 55,000 BTUH and a net cooling capacity of 12,000 – 30,000 BTUH
Revision Code
Series
NOMINAL COOLING CAPACITY12 - 12,000 Btu/hr 18 - 18,000 Btu/hr 24 - 24,000 Btu/hr 30 - 30,000 Btu/hr
P = 208/230 V - 60 Hz - 1 Ph
COOLING EFFICIENCY09 = 9.2 EER11 = Up to 11 EER
22 = 22,000 Btu/hr33 = 33,000 Btu/hr44 = 44,000 Btu/hr55 = 55,000 Btu/hr
H = Gas Heat
W = With
C = Electric Cooling
GAS HEAT EFFICIENCY9 = up to 95% TE
GAS HEAT FEATUREN = Stainless steel heat exchanger
R = Aluminized steel heat exchanger
GAS HEATING INPUT
H W C 9 N 55 11 P 18 A 1Model Number Guide
MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –
ECCO Supply™2-6 www.eccosupply.ca
Features• Standard and high efficiency cooling• Completely self-contained heating and cooling package • Microban® anti-microbial drain pan • No outside condensing unit • No external refrigerant lines • No separate cooling coil• Pre-wired and pre-charged• Individually metered and controlled• Slide-out cooling chassis
Refrigerant System• High efficiency compressor• Copper tubing with enhanced fin coil
Blower• Multispeed motor for wide airflow range• ECM blower motor in high efficiency units, PSC blower
motor in standard efficiency models• Dynamically balanced blower with resilient motor mounts
for smooth and quiet operation• Internal filter, optional MERV8
Controls• Colour-coded wiring for easy service
Installation• Plug & Play like features
V-SERIES PACKAGED THRU-THE-WALL UNITS (cont’d)EWC — ELECTRIC HEATING / ELECTRIC COOLINGElectric kW range of 5–20 kW and BTUH cooling range of 12,000–30,000
Model Number Guide
Revision Code
Series
NOMINAL COOLING CAPACITY12 - 12,000 Btu/hr 18 - 18,000 Btu/hr 24 - 24,000 Btu/hr 30 - 30,000 Btu/hr
P = 208/230 V - 60 Hz - 1Ph
COOLING EFFICIENCY9 = 9.2 EER11 = Up to 11.0 EER
E = Electric Heat
W = Thru-the-Wall
C = Electric Cooling
HEATER SIZE05 = 5kW07 = 7kW10 = 10kW15 = 15kW
E W C 05 11 P 18 A 1
MAGIC-PAKwww.magic-pak.com
Revised: June 2015 • Replaces: May 2013
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –
ECCO Supply™ www.eccosupply.ca 2-7
V-SERIES WALL SLEEVES• A wall sleeve is required
for every Magic-Pak installation
• Provides accurate opening during building construction
• Compatible with wood frame, cement block, poured concrete or metal stud walls
• 2", 6", 8", 10" and 12" sizes available
M-SERIES WALL SLEEVES• A wall sleeve is required for every
Magic-Pak installation• Provides accurate opening during
building construction• Compatible with wood frame,
cement block, poured concrete or metal stud walls
• 2", 6", 8", 10" and 12" sizes available