SS-GSZ16 www.goodmanmfg.com 12/16 Supersedes 11/16 Contents Nomenclature........................................ 2 Product Specificaons ........................... 3 Expanded Cooling Data ......................... 4 Expanded Heang Data....................... 18 Performance Data ............................... 20 AHRI Rangs ........................................ 21 Dimensions .......................................... 33 Wiring Diagrams .................................. 34 Accessories .......................................... 36 Cooling Capacity: 18,000 to 60,000 BTU/h Heating Capacity: 18,000 to 60,000 BTU/h Proper sizing and installaon of equipment is crical to achieving opmal performance. Split system air condioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. GSZ16 High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Online registraon is not required in California or Quebec. Standard Features High-efficiency scroll compressor SmartShiſt® technology to ensure quiet reliable defrost Single-speed ECM condenser fan motor Factory-installed bi-flow liquid-line filter drier Factory-installed sucon-line accumulator Factory-installed compressor crankcase heater Factory-installed high-capacity muffler High- and low-pressure switches Service valves with sweat connecons and easy access to gauge ports Copper tube/enhanced aluminum fin coil Fully charged for 15’ of tubing length Contactor with lug connecon Ground lug connecon AHRI Cerfied; ETL Listed Cabinet Features Goodman® brand sound control top design Steel louver coil guard Heavy-gauge galvanized-steel cabinet Aracve Architectural Gray powder-paint finish with 500-hour salt-spray approval Top and side maintenance access Service ports and controls are accessible while unit is operang When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Transcript
Page 1: * Not used for inventory control.literature.puertoricosupplier.com/086/RT85912.pdf2 SS-GSZ16 SS-GSZ16 3 Nomenclature G S Z 16 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering * G

SS-GSZ16 www.goodmanmfg.com 12/16Supersedes 11/16

ContentsNomenclature ........................................ 2Product Specifications ........................... 3Expanded Cooling Data ......................... 4Expanded Heating Data ....................... 18Performance Data ............................... 20AHRI Ratings ........................................ 21Dimensions .......................................... 33Wiring Diagrams .................................. 34Accessories .......................................... 36

Cooling Capacity: 18,000 to 60,000 BTU/hHeating Capacity: 18,000 to 60,000 BTU/h

Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

GSZ16High-Efficiency

Split System Heat PumpUp to 16 SEER & 9.0 HSPF

1½ to 5 Tons

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.

Standard Features• High-efficiency scroll compressor• SmartShift® technology to

ensure quiet reliable defrost• Single-speed ECM condenser fan motor• Factory-installed bi-flow liquid-line filter drier• Factory-installed suction-line accumulator• Factory-installed compressor crankcase heater• Factory-installed high-capacity muffler • High- and low-pressure switches• Service valves with sweat connections

and easy access to gauge ports• Copper tube/enhanced aluminum fin coil• Fully charged for 15’ of tubing length• Contactor with lug connection• Ground lug connection• AHRI Certified; ETL Listed

Cabinet Features• Goodman® brand sound control top design• Steel louver coil guard• Heavy-gauge galvanized-steel cabinet • Attractive Architectural Gray powder-paint

finish with 500-hour salt-spray approval• Top and side maintenance access• Service ports and controls are

accessible while unit is operating• When properly anchored, meets the 2010

Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

Page 2: * Not used for inventory control.literature.puertoricosupplier.com/086/RT85912.pdf2 SS-GSZ16 SS-GSZ16 3 Nomenclature G S Z 16 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering * G

2 www.goodmanmfg.com SS-GSZ16 SS-GSZ16 www.goodmanmfg.com 3

Nomenclature

G S Z 16 036 1 AA

1 2 3 4,5 6,7,8 9 10,11

Brand Engineering *

G Goodman® Brand Major & Minor revisions* Not used for inventory control.

Product Category

S Split System Electrical

1 - 208/230 V, 1 Phase, 60 Hz

Unit Type

X Condenser R-410A Nominal Capacity

Z Heat Pump R-410A 018 - 1½ tons 042 3½ Tons

024 - 2 tons 048 4 Tons

Efficiency 030 - 2½ tons 060 5 Tons

13 13 SEER 16 16 SEER 036 - 3 tons

14 14 SEER 18 18 SEER

Page 3: * Not used for inventory control.literature.puertoricosupplier.com/086/RT85912.pdf2 SS-GSZ16 SS-GSZ16 3 Nomenclature G S Z 16 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering * G

2 www.goodmanmfg.com SS-GSZ16 SS-GSZ16 www.goodmanmfg.com 3

Product Specifications

GSZ160181B*

GSZ160241B*

GSZ160301B*

GSZ160361B*

GSZ160421B*

GSZ160481B*

GSZ160601B*

Nominal Capacities

Cooling (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000

Heating (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000

Decibels 72 75 75 73 73 74 76

Compressor

RLA 9.0 10.9 13.4 14.1 16.7 19.9 28.8

LRA 47.5 62.9 72.5 72.2 109.0 109.0 152.9

Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll

Condenser Fan Motor

Horsepower 1/6 1/6 1/6 1/4 1/4 1/4 1/6

FLA 0.95 1.1 1.1 1.5 1.26 1.5 1

Refrigeration System

Refrigerant Line Size¹

Liquid Line Size (“O.D.) 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

Suction Line Size (“O.D.) 3/4" 3/4" 3/4" 7/8" 1 1/8" 1 1/8" 1 1/8"

Refrigerant Connection Size

Liquid Valve Size (“O.D.) 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

Suction Valve Size (“O.D.) 3/4" 3/4" 7/8” 7/8" 7/8” 7/8" 7/8"

Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat

Refrigerant Charge 140 150 160 175 180 231 291

Electrical Data

Volts/Phase (60 Hz) 208/230 208/230 208/230 208/230 208/230 208/230 208/230

Minimum Circuit Ampacity ² 12.2 14.7 18.0 19.1 22.1 26.4 37

Max. Overcurrent Protection ³ 20 25 30 30 35 45 60

Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253

Electrical Conduit Size 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4" 1/2" or 3/4"

Unit Weights

Equipment Weight 174 180 186 220 226 250 306

Shipping Weight 189 200 206 240 237 270 326

ENERGY STAR® Certified ^

^ Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must

be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. See Page 21 for all ENERGY STAR certified combinations

as of this document’s revision date.

¹ Tested and rated in accordance with AHRI Standard 210/240² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Notes• Always check the S&R plate for electrical data on the unit being installed.• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.• Installation of these units requires the specified TXV Kit to be installed on the indoor coil.

THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.

Page 4: * Not used for inventory control.literature.puertoricosupplier.com/086/RT85912.pdf2 SS-GSZ16 SS-GSZ16 3 Nomenclature G S Z 16 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering * G

32 www.goodmanmfg.com SS-GSZ16 SS-GSZ16 www.goodmanmfg.com 33

Dimensions

87

56

41

23

86

74

51

23

E D B AC

E D B AC

CON

FIDE

NTI

AL P

ROPE

RTY

OF

THE

GO

ODM

AN M

ANU

FACT

URI

NG

CO

MPA

NY,

L.P

. NO

T TO

BE

DISC

LOSE

D TO

OTH

ERS,

CO

PIED

, OR

USE

D FO

R AN

Y PU

RPO

SEEX

CEPT

AS

AUTH

ORI

ZED

IN W

RITI

NG

. M

UST

BE

RETU

RNED

UPO

N D

EMAN

D, O

N C

OM

PLET

ION

OF

ORD

ER, O

R O

THER

PU

RPO

SE F

OR

WH

ICH

IT W

AS L

ENT.

COM

PON

ENTS

AN

D M

ATER

IALS

SPE

CIFI

ED H

EREI

N W

ILL

ALSO

CO

NFO

RM T

O T

HE

APPL

ICAB

LE S

ECTI

ON

OF

GO

ODM

AN M

SP 8

24.0

1 W

ORK

MAN

SHIP

STAN

DARD

FO

R FI

T, F

EEL

AND

FIN

ISH

. S

PECI

AL C

HAR

ACTE

RIST

ICS:

=6S

IGM

A

=

CRIT

ICAL

CH

ARAC

TERI

STIC

= S

IGN

IFIC

ANT

CHAR

ACTE

RIST

ICSC

CC6s

ENG

: DW

N B

Y:

DO N

OT

SCAL

E DR

AWIN

G AREV

SHT

1 O

F 1

TOLE

RAN

CES:

ANG

LES

± 1.

5°.X

: ±

.1.X

X : ±

.03

.XXX

: ±

.015

HO

LE Ø

: ±

.005

TUBE

CU

T LG

: ± .0

63

DRAW

ING

TO

BE

INTE

RPRE

TED

INAC

CORD

ANCE

WIT

H A

SME

Y14.

100

DIM

ENSI

ON

S AR

E IN

INCH

ESU

NLE

SS O

THER

WIS

E N

OTE

D

ECN

REV

DESC

RIPT

ION

CHK

D DA

TEXX

XXXX

XA

-G

LZO

NE

XXXX

X

H

WD

Goo

dman

Man

ufac

turin

g Co

mpa

ny, L

.P.

Mod

elDi

men

sion

sW

”D”

H”

GSZ

1601

81L*

2929

36⅜

GSZ

1602

41L*

35½

35½

34⅝

GSZ

1603

01L*

35½

35½

34⅝

GSZ

1603

61L*

35½

35½

40

GSZ

1604

21L*

2929

36⅜

GSZ

1604

81L*

35½

35½

34⅝

GSZ

1606

01L*

35½

35½

40

GSZ

16 H

eat P

ump

Page 5: * Not used for inventory control.literature.puertoricosupplier.com/086/RT85912.pdf2 SS-GSZ16 SS-GSZ16 3 Nomenclature G S Z 16 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering * G

34 www.goodmanmfg.com SS-GSZ16 SS-GSZ16 www.goodmanmfg.com 35

Wiring Diagram — GSZ16018-481**

IND

OO

R P

OW

ER S

UPP

LY

NO

TES:

1. T

O IN

DO

OR

UN

IT L

OW

VO

LTAG

E TE

RM

INAL

BLO

CK

& IN

DO

OR

TH

ERM

OST

AT.

2. S

TAR

T AS

SIST

FAC

TOR

Y EQ

UIP

PED

WH

EN R

EQU

IRED

.3.

USE

CO

PPER

CO

NDUC

TOR

ON

LY.

4. C

RAN

KCAS

E H

EATE

R &

CR

ANKC

ASE

HEA

TER

SW

ITC

H A

RE

FAC

TOR

Y IN

STAL

LED

OPT

ION

.

CR

ANKC

ASE

HEA

TER

MAY

NO

T H

AVE

ADD

ITIO

NAL

GR

OU

ND W

IRE

5. 4

0VA

MIN

IMU

M T

RAN

SFO

RM

ER IS

REQ

UIR

ED.

6. C

OM

MO

N S

IDE

OF

TRAN

SFO

RM

ER M

UST

BE

GR

OUN

DED

.

CO

MP

ALTERNATE DOUBLEPOLE CONTACTOR ONLY

IO

T1

C

MAINR

AUX

5

S

SR

SA

21

RC

CF

SC

T2

C

L1

L2

(IF U

SED

)N

OTE

2CH

CF

MAIN

AUXIO C

M

0140

R00

171

- D

OR

BL/P

KBLR

D

O Y CR

COLO

R CO

DEBK

-----

------

---- B

LAC

KBL

/PK

------

---- B

LUE/

PIN

K ST

RIP

EBR

-----

------

---- B

RO

WN

GR-

------

------

--- G

REE

NO

R --

------

------

- OR

ANG

EPU

-----

------

---- P

URPL

ERD

-----

------

---- R

EDW

H --

------

------

WH

ITE

YL --

------

------

- YEL

LOW

YL/P

K----

------

- YEL

LOW

/PIN

K ST

RIP

E

CO

MPO

NEN

T C

OD

EC

-----

------

---- C

ON

TAC

TOR

CAD

M --

------

CO

MFO

RT

ALER

T D

IAG

NO

STIC

MO

DU

LECC

R --

------

--- C

OM

PRES

SOR

CO

NTA

CTO

R R

ELAY

CH --

------

-----

CRAN

KCAS

E H

EATE

RCH

S ---

------

-- C

RAN

KCAS

E H

EATE

R S

WIT

CH

CM

-----

------

- OU

TDO

OR

FAN

MO

TOR

CM

R --

------

-- C

OND

ENSE

R M

OTO

R R

ELAY

CO

MP

------

-- C

OM

PRES

SOR

CS

------

------

- CO

MPR

ESSO

R S

OLE

NO

IDDC

-----

------

-- D

EFR

OST

CO

NTR

OL

DFT

-----

------

DEF

RO

ST T

HER

MO

STAT

DT

------

------

- DIS

CHAR

GE

THER

MO

STAT

HPS

-----

------

HIG

H P

RES

SUR

E SW

ITC

HH

VDR

-----

--- H

IGH

VO

LTAG

E D

EFR

OST

REL

AYIO

-----

------

--- IN

TERN

AL O

VER

LOAD

LPS

----

------

LO

W P

RES

SUR

E SW

ITC

HLV

DR --

------

- LO

W V

OLT

AGE

DEF

RO

ST R

ELAY

LVJB

----

-----

LOW

VO

LTAG

E JU

NCTI

ON

BO

XRC

CF

------

--- R

UN C

APAC

ITO

R F

OR

CO

MPR

ESSO

R &

FAN

RVC

-----

------

REV

ERSI

NG

VAL

VE C

OIL

SA --

------

-----

STAR

T AS

SIST

SC --

------

-----

STAR

T C

APAC

ITO

R F

OR

CO

MPR

ESSO

R (O

PTIO

NAL

)SR

-----

------

-- ST

ART

REL

AY F

OR

CO

MPR

ESSO

R (O

PTIO

NAL

)C

ON

TRO

LS S

HO

WN

WIT

H T

HER

MO

STAT

IN 'O

FF' P

OSI

TIO

N.

OUT

DO

OR

PO

WER

SU

PPLY

SEE

RAT

ING

PLA

TE

LVJB

CO

NTR

OL

BOX

SC

RD

BL

L2T2

L1T1

C

BKBK

BKR

D RD

BL

RD

RC

CF

YL

BR

PU

RD

SR

5 21

BK YL

BL

IO CM

AUX

MAI

N

BRPU

YL

RD

BK

YL/P

K LPS

DF1 DF2

CH

LVD

R

R

CN

T

DFT

C

Y

DC

DFT

WH

W2

DC

BL/P

K

HPS

O

C

RVC

W2

R

HVD

R

YL/P

K

BK

BK

BL

BLC

HS

R-D

FT

C-R

VLP

S

PS2

O

WC

HPS

CC

R

}FIEL

D L

OW

VOLT

AGE

CO

NN

ECTI

ON

S

RD

BK

CH

SA(IF

USE

D)

NO

TE 2

DFT

RVC

RD

BKBL

/PK

BK

Y

T1 L1

T2 L2

R

DF1

DF2

0

0-RV

C-RV

W

LVDR

HVDR

CCR CNT

0

DFT

R-DF

T

R-PS

1

Y

Y

CR C C

PS2

RD

RD

BK

BK

SEE

NO

TE 4

SEE

NO

TE 5

& 6

BK

BK

RD

SEE

NO

TE 1

EQUI

PMEN

T G

RO

UND

SEE

NO

TE 3

ALTE

RNA

TED

OUB

LE P

OLE

CO

NTA

CTO

R

WH

BKBL

/PK

YL/P

K

YL/P

K

OR

PU

PU

CHS C

R

S

AUX

MAI

N

CO

MP

HF

C

RD

RD

YLYL

GR

USE

N.E

.C. C

LASS

2 W

IRE

SEE

NO

TE 4

RD

R-P

S1

O-R

V

WIR

ING

CO

DE

FAC

TOR

Y W

IRIN

GH

IGH

VO

LTAG

ELO

W V

OLT

AGE

OPT

ION

AL H

IGH

VO

LTAG

E

FIEL

D W

IRIN

GH

IGH

VO

LTAG

ELO

W V

OLT

AGE

SEE

NO

TE 1

Wiri

ng is

sub

ject

to c

hang

e. A

lway

s re

fer

to t

he w

iring

dia

gram

or

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

.⚠

W

arning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Fai

lure

to d

o so

may

cau

se p

rope

rty

dam

age,

per

sona

l inj

ury,

or d

eath

.⚡

Page 6: * Not used for inventory control.literature.puertoricosupplier.com/086/RT85912.pdf2 SS-GSZ16 SS-GSZ16 3 Nomenclature G S Z 16 036 1 AA 1 2 3 4,5 6,7,8 9 10,11 Brand Engineering * G

34 www.goodmanmfg.com SS-GSZ16 SS-GSZ16 www.goodmanmfg.com 35

Wiri

ng is

sub

ject

to c

hang

e. A

lway

s re

fer

to t

he w

iring

dia

gram

or

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

.⚠

W

arning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Fai

lure

to d

o so

may

cau

se p

rope

rty

dam

age,

per

sona

l inj

ury,

or d

eath

.⚡

USE

N.E

.C. C

LASS

2 W

IRE

COM

P

ALTERNATE DOUBLEPOLE CONTACTOR ONLY

IO

T1

C

MAINR

AUX

5

S

SR

SA

21

RCC

F

SC

T2

C

L1L2

(IF U

SED)

NO

TE 2C

H

C

F

MAIN

AUXIO CM

COLO

R CO

DEBK

-----

------

---- B

LACK

BL/P

K ---

------

- BLU

E/PI

NK S

TRIP

EBR

-----

------

---- B

RO

WN

OR

-----

------

---- O

RAN

GE

PU --

------

------

- PUR

PLE

RD

-----

------

---- R

EDW

H --

------

------

WH

ITE

YL --

------

------

- YEL

LOW

YL/P

K----

------

- YEL

LOW

/PIN

K ST

RIP

E

CO

MPO

NEN

T C

ODE

C --

------

------

- CO

NTA

CTO

RCC

R----

------

-- C

OM

PRES

SOR

CO

NTA

CTO

R R

ELAY

CH --

------

-----

CRAN

KCAS

E HE

ATER

CHS

------

-----

CRAN

KCAS

E HE

ATER

SW

ITCH

CM --

------

---- O

UTD

OO

R F

AN M

OTO

RCM

R --

------

-- C

OND

ENSE

R M

OTO

R R

ELAY

CO

MP

------

-- C

OM

PRES

SOR

CS --

------

-----

COM

PRES

SOR

SO

LEN

OID

DC --

------

-----

DEFR

OST

CO

NTR

OL

DFT

-----

------

DEF

RO

ST T

HER

MO

STAT

DT

------

------

- DIS

CHAR

GE

THER

MO

STAT

HPS-

------

-----

HIG

H P

RESS

URE

SW

ITC

HHV

DR

-----

--- H

IGH

VO

LTAG

E DE

FRO

ST R

ELAY

IO --

------

------

INTE

RNA

L O

VER

LOAD

LPS

------

------

LO

W P

RES

SURE

SW

ITC

HLV

DR --

------

- LO

W V

OLT

AGE

DEF

RO

ST R

ELAY

LVJB

-----

-----

LOW

VO

LTAG

E JU

NCTI

ON

BO

XRC

CF

------

--- R

UN C

APAC

ITO

R F

OR

CO

MPR

ESSO

R &

FAN

RVC

-----

------

REV

ERSI

NG V

ALVE

CO

ILSA

-----

------

-- ST

ART

ASSI

STSC

-----

------

-- ST

ART

CAPA

CIT

OR

FO

R C

OM

PRES

SOR

(OPT

IONA

L)SR

-----

------

-- ST

ART

RELA

Y FO

R C

OM

PRES

SOR

(OPT

IONA

L)

CO

NTR

OLS

SH

OW

N W

ITH

THE

RMO

STAT

IN 'O

FF' P

OSI

TIO

N.

OU

TDO

OR

PO

WER

SU

PPLY

SEE

RATI

NG

PLA

TE

WIR

ING

COD

EFA

CTO

RY

WIR

ING

HIG

H V

OLT

AGE

LOW

VO

LTAG

EO

PTIO

NAL

HIG

H V

OLT

AGE

FIEL

D W

IRIN

GH

IGH

VO

LTAG

ELO

W V

OLT

AGE

CONT

ROL

BOX

SC

RDBL

L2T2

L1T1

C

BKBK

BKRD

RD

BL

RD

RC

CF

BR

PU

SR

5 21

BK YL

BL

BKBR

PU

BK

YL/P

K LPS

DF1

DF2

(HIG

H)

CH

LVD

R

R

IND

OO

R P

OW

ER S

UPP

LY

Y

HPS

OW

2R

(LOW

)

542

HVD

R

CMR

(HIG

H)

(LO

W)

RD

BK

YL/P

K

CMR

BL

RDBK

134

25

RDRD

RD

BKBK

BL

YL/P

K

BL

PU

CHS

LPS

PS2

R-P

S1

O

W

CCR

Y

Y2C

Y2C

S

}FIEL

D L

OW

VOLT

AGE

CO

NN

ECTI

ON

S

BK

BK

RD

SA(IF

USE

D)NO

TE 2

BL/P

K

DFT

BK

RVC

BK

RDBK

DT

RD

RD

BL

BK

GR

BL/P

K

BK

BK

DT

HPS

CSC Y2

T1 L1

T2 L2

CN T

DFT

CDC

DFT

C

RVC

13

R-DF

T

O-R

V

CMR

C-RV

C

0140

R00

172-

C

DC

R

DF1

DF2

0

0-RV

C-RV

W

LVDR

HVDR

CCR

CNT

0

DFT

R-D

FT

R-P

S1

Y

Y

CR C C

PS2

RD RD

EQUI

PMEN

TG

RO

UND

NO

TE 4

NO

TES:

1) T

O IN

DOO

R U

NIT

LO

W V

OLT

AGE

TER

MIN

AL

BLO

CK A

ND

IND

OO

R TH

ERM

OST

AT.

2) S

TAR

T AS

SIST

FAC

TORY

EQ

UIP

PED

WH

EN

REQ

UIR

ED.

3) T

HE

CO

MM

ON

SID

E O

F LO

W V

OLT

AGE

SHAL

L

NO

T BE

GR

OU

NDED

.4)

USE

CO

PPER

CO

NDU

CTO

R O

NLY

.5)

CRA

NKC

ASE

HEAT

ER M

AY N

OT

H

AVE

ADD

ITIO

NAL

GR

OU

ND

WIR

E.6)

CRA

NKC

ASE

HEAT

ER &

CRA

NKCA

SE

HEA

TER

SW

ITC

H A

RE

FAC

TORY

IN

STAL

LED

OPT

ION

.SEE

NO

TE 6

YL

BL/

PK

YL/P

KPU

WH

PUO

R

OR

WH

RD PU BL YL

O W2

R Y C Y2

LVJB

ALTE

RN

ATE

DO

UBL

E PO

LEC

ON

TAC

TOR

CHS

CH

RD

BK

SEE

NOTE

1

BL

BK

IO

AUX

MAI

N

RD YL

CM

HF

C

YLYL

YL

YL/

PK

RD

RD

AUX

MAI

NCO

MP

CS

R

SEE

NO

TE 6

SEE

NOTE

1

Wiring Diagram — GSZ160601**


Recommended