2
Page 1 of 2 SUBMITTAL Job Name Location Purchaser Engineer Submitted to Reference Unit Designation Schedule# NJ0351HXCA www.Quietside.com Quietside maintains a policy of ongoing development, specifications are subject to change without notice. *Nominal cooling capacities are based on: Indoor temperature: 80F DB, 67F WB. Outdoor temperature: 95F DB, 75F WB. *Nominal heating capacities are based on: Indoor temperature: 70F DB, 60F WB. Outdoor temperature: 47F DB, 43F WB. Cooling (Btu/h) Heating (Btu/h) Type Output (W) Sound Level Accessories Front Panel (required) Wireless Remote Controller PSSMA MR-BH01U R410A Electronic Expansion Valve in outdoor unit 1/4" 3/8" VP20 (OD 1 , ID 3/4") 38 1/4 Specifications Safety Certifications ETL & ETLc 5 3/8 16 1/8 23 32/37 Height (inches) 1 Panel Dimensions (PSSMA) Panel Weight (lbs.) 7 Length (inches) 46 1/2 Width (inches) 26 1/2 High/Low (Db) 12,000 13,000 3.3 1/208-230/60 0.25 Crossflow Feedback SSR 30 283 318 Cooling High Motor 16 Up to 8.0 Fan Type Depth (inches) Height (inches) Width (inches) Control Method Type Refrigerant Piping Connections (inches) Liquid (flare) Drain (Quick Lock) Suction (flare) Unit Dimensions Weight (lbs.) Heating High Airflow (CFM) Performance Capacity Condensate (pints/hour) Power (Supplied by condenser) Voltage (ø/V/Hz) Running Current (amps) SEER HSPF Slim 1-Way Cassette for Samsung Free Joint Multi, Split Systems • Electro-static, washable, pleated filter as standard • Built in drain pump with check valve, maximum 29" lift Construction UL94 V0 fascia panel and insulated chasis Heat Exchanger The heat exchanger shall be mechanically bonded fin to copper tube Indoor Fan Indoor fan is a single crossflow type Three fan speed settings and auto setting Controls The unit shall be operated via a wireless or wired remote control with DDC type signal Control wiring shall be 16AWG X 2 shielded wire MWR-WH00 wired controller ships with unit as standard Compatibility This unit will only operate with Samsung Free Joint Multi (FJM) condensing units: MH050FXCA2A and MH080FXCA4A Approval Construction QS-FJM-0311
Transcript

Page 1 of 2SUBMITTAL

Job Name LocationPurchaser EngineerSubmitted to ReferenceUnit Designation Schedule#

NJ0351HXCA

www.Quietside.comQuietside maintains a policy of ongoing development, specifications are subject to change without notice.

*Nominal cooling capacities are based on: Indoor temperature: 80⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.*Nominal heating capacities are based on: Indoor temperature: 70⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.

Cooling (Btu/h)

Heating (Btu/h)

Type

Output (W)

Sound Level

AccessoriesFront Panel (required)

Wireless Remote Controller

PSSMA

MR-BH01U

R410A

Electronic Expansion Valve in outdoor unit

1/4"

3/8"

VP20 (OD 1 , ID 3/4")

38 1/4

Specifications

Safety Certifications ETL & ETLc

5 3/8

16 1/8

23

32/37

Height (inches) 1

Panel Dimensions (PSSMA)

Panel Weight (lbs.) 7

Length (inches) 46 1/2

Width (inches) 26 1/2

High/Low (Db)

12,000

13,000

3.3

1/208-230/60

0.25

Crossflow

Feedback SSR

30

283

318

Cooling High

Motor

16

Up to 8.0

Fan

Type

Depth (inches)

Height (inches)

Width (inches)

Control Method

TypeRefrigerant

Piping Connections (inches)

Liquid (flare)

Drain (Quick Lock)

Suction (flare)

Unit Dimensions

Weight (lbs.)

Heating HighAirflow (CFM)

Performance

Capacity

Condensate (pints/hour)

Power (Supplied by condenser)

Voltage (ø/V/Hz)

Running Current (amps)

SEER

HSPF

Slim 1-Way Cassette for Samsung Free Joint Multi, Split Systems

• Electro-static, washable, pleated filter as standard

• Built in drain pump with check valve, maximum 29" lift

ConstructionUL94 V0 fascia panel and insulated chasis

Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube

Indoor FanIndoor fan is a single crossflow type

Three fan speed settings and auto setting

ControlsThe unit shall be operated via a wireless or wired remote control with DDC type signal

Control wiring shall be 16AWG X 2 shielded wire

MWR-WH00 wired controller ships with unit as standard

CompatibilityThis unit will only operate with Samsung Free Joint Multi (FJM) condensing units: MH050FXCA2A and MH080FXCA4A

Approval Construction

QS-FJM-0311C

SUBMITTAL NJ0351HXCA

Quietside West : 8750 Pioneer Blvd, Santa Fe Springs, CA 90670 • Phone : 888-699-6067 • Fax : 562-699-4351Quietside Central : 3001 Northern Cross Blvd. Suite 361, Fort Worth, TX 76137 • Phone : 817-838-6066 • Fax : 817-838-8670

Quietside East : 6 Pine Hill Drive, Carlisle, PA 17013 • Phone : 1-877-262-4731 • Fax : 717-243-7917

www.Quietside.com

Unit: Inches

Slim 1-Way Cassette for Samsung Free Joint Multi, Split Systems