Date post: | 23-May-2018 |
Category: |
Documents |
Upload: | truongquynh |
View: | 231 times |
Download: | 0 times |
www.courbi.com
We welcome you at the KOUROUPIS – BINIARIS SA web site. At the new version of our web site you can
find the new product catalogue and also all the information about our new products and latest news about
our activities. In addition at www.courbi.com you can download the product catalogue and other product
brochures and also the ISO product certificates.
Enjoy the navigation
SalonicaSalonica
Korinthos Korinthos
HeraklionCrete HeraklionCrete
Our Company The Company KOUROUPIS – BINIARIS SA (COURBI SA) has being operating for over 30 years. We at COURBI by placing great effort to understand and project the needs of the greek and global environment, having human resources with high tech education and also respecting each customer, have managed to become the number one company in the market.
With very well organized premises and with all the new logistics systems we guarantee the immediate delivery of our products.
The main production facility is based at privately owned modern plant at Solomos Korinthias while the company also has distributors at:
• Korinthos • Salonica• Heraklion Crete • Bucharest
Our philoshophy on which the future of the company is based is:
TOTAL QUALITY OF PRODUCTS AND SERVICES
Quality Management
The policy of our Company is to provide our customers with high quality products; this quality is ensured through the implementation of a Quality System according to ISO 9001:
2000.
The establishment and implementation of the Quality
System in the company is carried out keeping in mind the
constant improvement of both the system as well as the
quality of the products manufactured.
New Products 2009
Courbox - Switch boxes EVO
Courbox - Switch boxes FRAME
Courbox - Switch boxes MODUL 3/4/6
Courbox - Junction boxes O/ 100
Courbox - Junction boxes ULTRA
Courbox - Plasterboard Switch boxes
Courbox - Plasterboard Junction boxes
Courbox- Watertight Elements ΙP54 - Switches/Sockets
Courbox - Watertight Junction Boxes IP54 65x65x40
Contents
FLEXIBLE CONDUITS
Si Bi Super page 8
Si Bi Wire page 9
Spiral Courbi DIN - Light Type 320Ν page 10
Spiral Courbi DIN - Medium Type 750Ν page 11
Spiral Courbi EURO - Light Type 320Ν page 12
Spiral Courbi EURO - Medium Type 750Ν page 13
Spiral Courbi EURO - Heavy Type 1250Ν page 14
Spiral Courbi EURO Halogen Free -
Medium Type 750Ν page 15
SPECIAL FLEXIBLE CONDUITS
Courfl ex® page. 18
Di Flex® page 19
Betosol® page 20
EL FLEX® page 21
Steel Spiral - Heavy Type 1250Ν page 22
STRAIGHT CONDUITS
Courline STRAIGHT CONDUIT DIN- Light Type 320Ν page 25
Courline EURO - Light Type 320Ν page 26
Courline EURO - Medium Type 750N page 27
Courline EURO - Heavy Type 1250N page 28
Courline EURO Halogen Free
- Medium Type 750N page 29
CONDUIT CONNECTION, SUPPORT
& CUTTING ACCESSORIES
Couplings page 32
Bend 900 page 32
Angle 900 page 32
“Τ” Joint page 33
Racor page 33
Flexible Connection page 33
Snap Clip Supports page 34
Omega Clip Supports page 34
Support Guide Rail page 35
Conduit Cutting Scissors page 35
Gland Racor Courfl ex page 35
Halogen Free Couplings page 36
Bend 900 Halogen Free page 36
Racor Connection Box - Conduit Halogen Free page 37
Halogen Free Snap Clip Supports page 37
COURBOX
ELECTRICAL INSTALLATION ELEMENTS
Junction Boxes page 40
Junction Boxes ULTRA page 41
Switch Boxes Super page 42
Switch Boxes EVO page 43
Connected Switch Boxes - FRAME page 44
Switch Boxes MODUL page 45
Plasterboard Junction Boxes page 46
Plasterboard Switch Boxes
(single-double-triple) page 47
Switch Boxes D65 page 48
Spotlight Boxes page 49
Watertight Junction Boxes IP54 page 50
Watertight External Elements IP54 page 51
CABLE DISTRIBUTION CHANNELS
Channels page 54
Floor Mounted page 55
Air Conditioning Drainage page 55
SUPPORT & PROTECTION ACCESSORIES
Cable Ties page 58
Roca Supports page 59
Plugs page 60
Plugs with nailed screw page 60
Sico Fastening Nails O/ 2 Χ 12
- with plastic coating page 61
Fix Pin Fastening Nails page 61
Robot Μ6 Fastening Nails page 61
Punches - FixPin - Robot page 61
Terminal Strips page 62
Cable Connewction Protection
Caps page 62
Socket Protection Caps page 63
Panel Filling Flange page 63
Support Strap page 63
Nylon Cable Puller page 63
TECHNICAL GUIDE page 65-74
Flexible Conduits
Si Bi Super
Si Bi Wire
Spiral DIN - Light Type 320Ν
Spiral DIN - Medium Type 750Ν
Spiral EURO - Light Type 320Ν
Spiral EURO - Medium Type 750Ν
Spiral EURO - Heavy Type 1250Ν
Spiral EURO - Halogen Free - Medium Type 750Ν
8
SiBi® SuperGENERAL DESCRIPTION• Pliable, with special coating • Suitable for light and medium mechanical loads > 500N• Made of polyvinyl chloride, conduit: (U-PVC), coating: (P-PVC)• Self extinguishing; flame retardant
APPLICATIONS• Indoor residential and industrial installations• Encased in concrete• Infloor installations • Available with special coupling for quick and easy connection• Fits with: Courbox Junction, Spotlight
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004, DIN 49018 (Dimensions)
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C >500Ν / 5cm 2Resistance to Impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 2321
TYPE 11 13.5 16 23CODE 04-21006-S11 04-21007-S13 04-21008-S16 04-21009-S23PACKAGING – ROLL LENGTH / m 50 50 50 25Ο/ EXTERNAL DIAMETER / mm 15.6 18.3 21 28Ο/ Min. INT. DIAMETER / mm (±0.1) 11.8 14 16.5 23.3COLOR GRAY (RAL.7035)
Flexible Conduits
9
SiBi® WireGENERAL DESCRIPTION
• Pliable, with special coating and metalic cable puller inside • Suitable for medium mechanical loads >500N• Made of polyvinyl chloride, conduit: (U-PVC), coating: (P-PVC)• Self extinguishing; flame retardant
APPLICATIONS • Indoor residential and industrial installations• Encased in concrete• Infloor installations • With special galvanized wire internally, for quick and easy installation of cables• Type of wire: Ο/ 0,8 mm - 700/810 N/mm2
• Fits with: Courbox, Spotlight
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004, DIN 49018 (Dimensions)
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 500 Ν / 5cm 2Resistance to Impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100ΜΩCLASSIFICATION CODE ΕΝ: 61386-1 2321
TYPE 11 B 13.5 B 16 B 23 BCODE 04-21001-B11 04-21002-B13 04-21003-B16 04-21004-B23PACKAGING – ROLL LENGTH / m 50 50 50 25Ο/ EXTERNAL DIAMETER / mm 15.6 18.3 21 28Ο/ Min. INT. DIAMETER / mm (±0.1) 11.8 14 16.5 23.3COLOR BLUE (RAL.5005)
Galvanized wire Diameter: Ο/ 0.8mm Pulling Force: 700-850 N/mm2
Flexible Conduits
10
Spiral DIN - Light Type 320NGENERAL DESCRIPTION• Corrugated (spiral), pliable• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardant
APPLICATIONS• Indoor residential and industrial installations• Cable routing through masonry – Flush installations• Fits with: Courline Straight L/T, Courbox Junction, Switches, Plasterboard
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004, DIN 49018 (Dimensions)
PROPERTIESREQUIREMENT CLASSIFICATIONCompression strength – (compressive force) at 22 ±2 0C 320 N / 5cm 2Impact strength – (Weight mass/ Fall height) at -5 0C m:1kg / h:100mm 2Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric Strength 2 kv / 15 minInsulation Resistance 100 ΜΩCLASSIFICATION CODE ΕΝ.61386-1 2221
TYPE 11 13.5 16 23CODE 03-21025-L11 03-21026-L13 03-210027-L16 03-21028-L23ROLL LENGTH / m 50 50 50 25PACKAGING 200 200 200 100Ο/ EXTERNAL DIAMETER / mm (±0.1) 16 18.7 21.2 28.3Ο/ Min. INT. DIAMETER / mm (±0.1) 12 14.5 17 24COLOR WHITE (RAL.9018) GRAY (RAL.7035) RED GREEN BLUE*
Flexible Conduits
11
Spiral DIN - Medium Type 750NGENERAL DESCRIPTION• Corrugated (spiral), pliable• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardantα• UV protection
APPLICATIONS• Indoor or outdoor residential and industrial installations• Cable routing through masonry – Flush installations• Encased in concrete. Infloor installations • Available with special coupling for quick and easy connection • Fits with: Courline Straight L/T, Courbox Junction, Switches, Plasterboard
Available with special galvanized wire internally for quick and easy installation of cablesupon order with an extra charge of 0,06 €/m
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004, DIN 49018 (Dimensions)
PROPERTIESREQUIREMENT CLASSIFICATIONCompression strength – (compressive force) at 22 ±2 0C 750 N / 5cm 3Impact strength – (Weight mass/ Fall height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric Strength 2 kv / 15 minInsulation Resistance 100 ΜΩCLASSIFICATION CODE EN.61386-1 3321
TYPE 11 13.5 16 23CODE 03-21001-011 03-21002-135 03-21003-016 03-21004-023PACKAGING - ROLL LENGTH / m 50 50 50 25Ο/ EXTERNAL DIAMETER / mm 16 18.7 21.2 28.3Ο/ Min. INT. DIAMETER / mm (±0.1) 11.5 14 16.6 23.5COLOR GRAY (RAL.7040)
Flexible Conduits
12
Spiral ΕURO - Light Type 320NGENERAL DESCRIPTION• Corrugated (spiral), pliable• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardan
APPLICATIONS• Indoor residential and industrial installations• Cable routing through masonry – Flush installations• Fits with: EURO conduit connection
Available with special galvanized wire internally for quick and easy installation of cablesupon order with an extra charge of 0,06 €/m
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 320 N / 5cm 2Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:1kg / h:100mm 2Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric Strength 2 kv / 15 minInsulation Resistance 100 ΜΩCLASSIFICATION CODE EN.61386-1 2221
TYPE 16 20 25 32CODE 31-21025-016 31-21026-020 31-21027-025 31-21028-032ROLL LENGTH / m 50 50 50 25PACKAGING / m 200 200 100 100Ο/ EXTERNAL DIAMETER / mm (±0.1) 16 20 25 32Ο/ Min. INT. DIAMETER / mm (±0.1) 11.3 14.6 18.5 24.5COLOR GRAY (RAL.7035) BLACK
Flexible Conduits
13
Spiral ΕURO - Medium Type 750NGENERAL DESCRIPTION• Corrugated (spiral), pliable, Suitable for medium mechanical loads• Made of polyvinyl chloride – (U-PVC), Self extinguishing; flame retardant• UV protection
APPLICATIONS• Outdoor residential and industrial installations• Encased in concrete • Infloor installations, Wall mounted installations (supports – collars) • Cable routing through masonry – Flush installations• Fits with: Courline EURO, EURO accessories, Courbox
Available with special galvanized wire internally for quick and easy installation of cablesupon order with an extra charge of 0,06 €/m
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 750 N / 5cm 3Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance 100 ΜΩCLASSIFICATION CODE EN.61386-1 3321
TYPE 16 20 25 32 40 50CODE 31-21001-016 31-21002-020 31-21003-025 31-21004-032 31-21005-040 31-21006-050
PACKAGING – ROLL LENGTH / m 50 50 50 50 25 25Ο/ EXTERNAL DIAMETER / mm 16 20 25 32 40 50Ο/ Min. INT. DIAMETER / mm (±0.1) 11.1 14.5 18.4 24.4 31.1 39.5COLOR GRAY (RAL.7035)
Flexible Conduits
14
Spiral ΕURO - Heavy Type 1250NGENERAL DESCRIPTION• Corrugated (spiral), pliable• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardant• UV protection
APPLICATIONS• Residential and industrial installations• Encased in concrete • Infloor installations • Wall mounted installations (supports – collars)• Fits with: Courline EURO, Courbox, EURO accessories
Available with special galvanized wire internally for quick and easy installation of cablesupon order with an extra charge of 0,06 €/m
APPLICATION STANDARDS: EN.61386-1/2004, EN.61386-22/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 1250 N / 5cm 4Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:300mm 4Minimum temperature limit -50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE ΕΝ.61386-1 4421
TYPE 16 20 25 32 40 50CODE 31-21007-016 31-21008-020 31-21009-025 31-21010-032 31-21011-040 31-21012-050
PACKAGING - ROLL LENGTH / m 50 50 50 50 25 25Ο/ EXTERNAL DIAMETER / mm 16 20 25 32 40 50Ο/ Min. INT. DIAMETER / mm (±0.1) 10.8 14.1 18.3 24.3 31 39.4COLOR GRAY (RAL.7035)
Flexible Conduits
15
Spiral EURO Halogen Free - Medium Type 750ΝGENERAL DESCRIPTION• Corrugated (spiral), pliable, suitable for medium mechanical loads• Made of special halogen free and low smoke emission thermoplastic material• Self extinguishing; flame retardant, UV protection
APPLICATIONS• Suitable for common use spaces, where flame retardation, low smoke emission and zero toxic or corrosive
gas emission is required in case of fire. • Outdoor residential and industrial installations• Encased in concrete • Infloor installations, wall mounted installations (supports – collars) • Fits with: EURO Halogen Free, Courline EURO Halogen Free, Courbox Halogen Free connection accessories
Available with special galvanized wire internally for quick and easy installation of cablesupon order with an extra charge of 0,06 €/m
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 750 N / 5cm 3Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 150C 3Maximum temperature limit + 900C 2Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 3332
TYPE 16 20 25 32 40 50CODE 31-... 21043-H16 21044-H20 21045-H25 21046-H32 21047-40 21048-H50PACKAGING - ROLL LENGTH / m 50 50 50 50 25 25Ο/ EXTERNAL DIAMETER / mm 16 20 25 32 40 50Ο/ Min. INT. DIAMETER / mm (±0.1) 11.1 14.5 18.4 24.4 31.1 39.5COLOR GRAY (RAL.7035)
Flexible Conduits
Special Flexible Conduits
Courflex®
Di Flex®
Betosol®
EL - FLEX®
Steel Spiral
18
Courflex®
GENERAL DESCRIPTION• Flexible spiral • Made of polyvinyl chloride – (P-PVC), reinforced with a spiral made of polyvinyl chloride – (U-PVC)• Suitable for light mechanical loads • Self extinguishing; flame retardant
APPLICATIONS• Residential and industrial installations• Infloor, wall mounted installations – Equipment manufacturing • Air Conditioning drainage • Connection with gland - Racor Courflex • Fits with: Courline EURO, Courbox Watertight, Watertight External Elements IP 54
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-23/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 320 N/ 5cm 2Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit + 50C 1Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 2311
TYPE 12 14 16 18 20 22 25 30 38 50 62CODE 16-210... 12-L12 13-L14 14-L16 15-L18 16-L20 17-L22 18-L25 19-L30 20-L38 22-L50 23-L62
PACKAGING - ROLL LENGTH / m 30 30 30 30 30 30 30 30 30 30 30Ο/ EXTERNAL DIAMETER / mm 16 16.3 20 21.2 22.5 25.3 28.1 36 44.5 55.5 69Ο/ Min. INT. DIAMETER / mm (±0.1) 12 14 16 18 20 22 25 30 38 50 62COLOR GRAY (RAL.7035) RED GREEN BLUE* WHITE
Special Flexible Conduits
19
Di Flex®
GENERAL DESCRIPTION• Flexible spiral • Made of polyvinyl chloride – (P-PVC), reinforced with a spiral made of polyvinyl chloride – (U-PVC)• Suitable for light mechanical loads • Special internal threading for quick and easy routing of cables • Self extinguishing; flame retardant
APPLICATIONS • Residential and industrial installations• Infloor, wall mounted installations • Encased in concrete • Underground networks, lighting supply lines, (roads, squares, sidewalks)• Connection with gland • Fits with: Courbox Watertight
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-23/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 320 N/ 5cm 2Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 2321
TYPE 12 14 16 18 22 25 30 34 38 50 62CODE 16-210... 01-012 02-014 03-016 04-018 05-022 06-025 07-030 08-034 09-038 10-050 11-062
PACKAGING - ROLL LENGTH / m 50 50 50 50 50 50 50 50 50 50 50Ο/ EXTERNAL DIAMETER / mm 16 16.5 20 21.2 25.3 28.1 36 38 44.5 55.5 68Ο/ Min. INT. DIAMETER / mm (±0.1) 12 14 16 18 22 25 31 34 38 50 64COLOR GRAY (RAL.7001)
Special Flexible Conduits
20
Betosol®
GENERAL DESCRIPTION• Corrugated (spiral), pliable• Suitable for light and medium mechanical loads• Made of special polymer material• Resistant to impact, acids and solvents
APPLICATIONS• Indoor residential and industrial installations• Encased in concrete• Infloor installations • Available with special galvanized wire internally for quick and easy installation of cables• Fits with: Courbox Junction Box, Switch Box, Spotlight Box
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004, DIN 49018 (Dimensions)
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 320 N / 5cm 2Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 150C 3Maximum temperature limit + 900C 2Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 2332
TYPE 13.5 16 23CODE 07-21004-P13 07-21005-P16 07-21006-P23PACKAGING - ROLL LENGTH / m 50 50 50Ο/ EXTERNAL DIAMETER / mm (±0.1) 18.3 21 27,7Ο/ Min. INT. DIAMETER / mm (±0.1) 13.4 16.4 23COLOR ORANGE (RAL.2004)
Special Flexible Conduits
21
ΕL FLEX®
GENERAL DESCRIPTION• Semi-flexible, corrugated (spiral)• Made of special polymer material
APPLICATIONS• Underground networks, lighting supply lines to roads, squares, sidewalks• Infloor installations • Encased in concrete• Resistant to acids and solvents
APPLICATION STANDARDS: EN 50086-1, EN 50086-2-4
PROPERTIESREQUIREMENT Resistance to compression – (compression force) at 22 ±2 0C 450 N / 5cmResistance to impact – (Weight mass/ Fall Height) at -5 0C m:3kg / h:100mmMinimum temperature limit - 250CMaximum temperature limit + 1050CDielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION ΕΝ.50086-1 L - DUTY
TYPE 23 29 48CODE 05-21001-P23 05-21002-P29 05-21003-P48PACKAGING - ROLL LENGTH / m 50 50 25Ο/ EXTERNAL DIAMETER / mm (±0.1) 32 40 57.5Ο/ Min. INT. DIAMETER / mm (±0.1) 23.5 30.8 48COLOR ORANGE (RAL.2004)
Special Flexible Conduits
22
Steel Spiral - Heavy Type 1250NGENERAL DESCRIPTION• Corrugated (spiral), pliable• Suitable for heavy mechanical loads• Made of steel lamina internally and externally with special insulation in between• Incombustible
APPLICATIONS• Residential and industrial installations• Enclosed in concrete - asphalt• Infloor installation • Wall/floor mounted installations (supports – collars)• Available with special coupling for quick and easy connection • Fits with: Courbox, Courline EURO H/T
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-22/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 1250 Ν / 5cm 4Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:300mm 4Minimum temperature limit - 450C 5Maximum temperature limit + 2500C 6Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE ΕΝ.61386-1 4456
TYPE 16 20 25 32CODE 19-20004-016 19-20005-020 19-20006-025 19-20007-032PACKAGING - ROLL LENGTH / m 25 25 25 25Ο/ EXTERNAL DIAMETER / mm (±0.1) 16 20 25 32Ο/ Min. INT. DIAMETER / mm (±0.1) 11.7 15.7 20.2 26.7
Special Flexible Conduits
Straight Conduits
Courline STRAIGHT DIN - Light Type 320N
Courline EURO - Light Type 320Ν
Courline EURO - Medium Type 750Ν
Courline EURO - Heavy Type 1250Ν
Courline EURO - Ηalogen Free - Medium Type 750Ν
25
Courline STRAIGHT DIN - Light Type 320NGENERAL DESCRIPTION• Rigid• Suitable for light mechanical loads• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardant
APPLICATIONS• Indoor residential and industrial installations• Cable routing through masonry – Flush installations • Fits with: Its external diameter fits to the internal diameter of the corresponding Spiral Din Light Type conduit,
Courbox Junction Box, Switch Box and Switch Box for plasterboard
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-21/2004, Τ.Φ.Π (External Diameter)
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 320 N / 5cm 2Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:1kg / h:100mm 2Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 2221
TYPE 11 13,5 16 23CODE 03-21025-L11 03-21026-L13 03-210027-L16 03-21028-L23CONDUIT LENGTH / m 3 3 3 3PACKAGING 300 300 300 150Ο/ EXTERNAL DIAMETER / mm (±0.1) 11.7 14.3 16.8 23.3Ο/ Min. INT. DIAMETER / mm (±0.1) 10.6 12.8 15.5 22COLOR WHITE (RAL.9018) GRAY (RAL.7035) RED GREEN BLUE*
Straight Conduits
26
Straight Conduits
Courline ΕURO - Light Type 320NGENERAL DESCRIPTION• Rigid• Suitable for light mechanical loads• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardant
APPLICATIONS• Indoor residential and industrial installations• Cable routing through masonry – Flush installations • Fits with: Spiral EURO L/T, Courbox
APPLICATION STANDARDS: ΕΝ 61386-1/2004, EN 61386-21/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 320 Ν / 5cm 2Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:1kg / h:100mm 2Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE ΝΕ.61386-1 2221
TYPE 16 20 25 32CODE 30-21013-E16 30-21014-E20 30-21015-E25 30-21016-E32CONDUIT LENGTH / m 3 3 3 3PACKAGING 300 300 300 150Ο/ EXTERNAL DIAMETER / mm (±0.1) 16 20 25 32Ο/ Min. INT. DIAMETER / mm (±0.1) 14 17.5 22.5 28COLOR GRAY (RAL.7035)
27
Straight Conduits
Courline ΕURO - Medium Type 750NGENERAL DESCRIPTION• Rigid• Suitable for medium mechanical loads• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardant • UV protection
APPLICATIONS• Outdoor or indoor residential and industrial installations• Cable routing in motion – lighting installations • Ability to configure networks with EURO connection and support accessories • Infloor – Wall mounted installations • Encased in concrete• Fits with: EURO connection accessories, Spiral EURO M/T, Courflex, Courbox
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-21/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 750 N/ 5cm 3Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 3321
TYPE 16 20 25 32 40 50CODE 30-2... 1007-M16 1008-M20 1009-M25 1010-M32 1011-M40 1012-M50LENGTH / m 3 3 3 3 3 3PACKAGING 30 30 15 15 9 9Ο/ EXTERNAL DIAMETER / mm 16 20 25 32 40 50Ο/ Min. INT. DIAMETER / mm (±0.1) 13.5 17 21.5 27.5 35 44.5COLOR GRAY (RAL.7035)
28
Straight Conduits
Courline ΕURO - Heavy Type 1250NGENERAL DESCRIPTION• Rigid• Suitable for heavy mechanical loads• Made of polyvinyl chloride – (U-PVC)• Self extinguishing; flame retardant• UV protection
APPLICATIONS• Outdoor or indoor residential and industrial installations• Cable routing in motion – lighting installations • Ability to configure networks with EURO connection and support accessories • Infloor – Wall mounted installations • Encased in concrete• Fits with: EURO connection accessories, Spiral EURO M/T, Courflex, Courbox
APPLICATION STANDARDS: EN 61386-1/2004, EN 61386-21/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 1250 N / 5cm 4Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:300mm 4Minimum temperature limit - 50C 2Maximum temperature limit + 600C 1Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE EN.61386-1 4421
TYPE 16 20 25 32 40 50CODE 30-2... 1001-016 1002-020 1003-025 1004-032 1005-040 1006-050LENGTH / m 3 3 3 3 3 3PACKAGING 30 30 15 15 9 9Ο/ EXTERNAL DIAMETER / mm 16 20 25 32 40 50Ο/ Min. INT. DIAMETER / mm (±0.1) 13 16.5 21.3 27.2 34.5 44COLOR GRAY (RAL.7035)
29
Straight Conduits
Courline EURO Halogen Free - Medium Type 750ΝGENERAL DESCRIPTION• Rigid• Suitable for medium mechanical loads• Made of halogen free and low smoke emission thermoplastic material• Self extinguishing; flame retardant• UV protection
APPLICATIONS• Suitable for common use spaces, where flame retardation, low smoke emission and zero toxic or corrosive
gas emission is required in case of fire. • Outdoor or indoor residential and industrial installations• Cable routing in motion – lighting installations • Ability to configure networks with Halogen Free accessories • Infloor – Wall mounted installations • Encased in concrete• Fits with : EURO Halogen Free, Spiral, EURO Halogen Free, Courbox Halogen Free
APPLICATION STANDARDS: ΕΝ 61386-1/2004, EN 61386-21/2004
PROPERTIESREQUIREMENT CLASSIFICATIONResistance to compression – (compression force) at 22 ±2 0C 750 N/ 5cm 3Resistance to impact – (Weight mass/ Fall Height) at -5 0C m:2kg / h:100mm 3Minimum temperature limit -250C 4Maximum temperature limit + 900C 2Dielectric strength 2 kv / 15 minInsulation resistance > 100 ΜΩCLASSIFICATION CODE ΕΝ.61386-1 3342
TYPE 16 20 25 32 40 50CODE 30-2... 1031-H16 1032-H20 1033-H25 1034-H32 1035-H40 1036-H50LENGTH / m 3 3 3 3 3 3PACKAGING 30 30 15 15 9 9Ο/ EXTERNAL DIAMETER / mm 16 20 25 32 40 50Ο/ Min. INT. DIAMETER / mm (±0.1) 13.5 17 21.5 27.5 35 44.5COLOR GRAY (RAL.7035)
COURFLEX
RACOR
WATERTIGHT JUNCTION BOXES
COUPLINGS
FLEXIBLE CONNECTION
SNAP CLIP SUPPORTS
ANGLE 90o
WATERTIGHT JUNCTION BOXES
SPIRAL EURO
OMEGA CLIP SUPPORTS
SUPP
ORT
GU
IDE
RA
IL CO
UPL
ING
SO
MEG
A C
LIP
SUPP
ORT
S
ANGLE 900“Τ” JOINT
GLANDRACOR-COURFLEX
Couplings
Angle 90ο
Racor
Support Guide Rail
Conduit Cutting Scissors
Couplings Halogen Free
Racor Halogen Free
Bend 90ο
“Τ” Joint
Flexible Connection
Snap clip & Omega Clip Supports
Gland Racor Courflex
Halogen FreeBend 90ο
Halogen Freesnap clip supports
Conduit connection, support and cutting accessories
NEW
32
Conduit connection, support and cutting accessories
• Special coupling for the connection of straight and flexible conduits
• Water tightness level: IP 40 – (IP55 use of glue)
• Fits with: Courline EURO, Spiral EURO, Courflex
TYPE 16 20 25 32 40 50For conduits with an ext. Diameter of / mm 16 20 25 32 40 50CODE 38-20... 001-016 002-020 003-025 004-032 005-040 006-050 PACKAGING Bag 10 10 10 5 • •PACKAGING Carton box 400 250 150 80 10 10COLOR GRAY (RAL.7035)
Couplings
Bend 90°
• Fixed special bend for the connection of straight and flexible conduits
• Water tightness level: IP 40 – (IP 55 use of glue)
• Fits with: Courline EURO, Spiral EURO, Courflex
TYPE 16 20 25 32 40 50For conduits with an ext. Diameter of / mm 16 20 25 32 40 50CODE 39-2.. 0007-016 0008-020 0009-025 0010-032 0011-040 0012-0506 PACKAGING Bag 10 10 10 5 • •PACKAGING Carton box 150 100 250 150 100 100COLOR GRAY (RAL.7035)
Angle 90° • Fixed for the connection of straight and flexible conduits
• Splitable to 2 pieces – ability to control cables
• Water tightness level: IP 40
• Fits with: Courline EURO, Spiral EURO, Courflex
TYPE 16 20 25 32For conduits with an ext. Diameter of / mm 16 20 25 32CODE 36-20001-016 36-20002-020 36-20003-025 36-20004-032PACKAGING Bag 10 10 10 5PACKAGING Carton box 250 250 250 150COLOR GRAY (RAL.7035)
33
Conduit connection, support and cutting accessories
“Τ” Joint
Racor
• Special for the connection of straight and flexible conduits
• Splitable to 2 pieces – ability to control cables
• Water tightness level: IP 40
• Fits with: Courline EURO, Spiral EURO, Courflex
TYPE 16 20 25 32For conduits with an ext. Diameter of / mm 16 20 25 32CODE 37-20001-016 37-20002-020 37-20003-025 37-20004-032PACKAGING Bag 10 10 10 5PACKAGING Carton box 250 250 250 150COLOR GRAY (RAL.7035)
• Elastic connection of Courbox watertight boxes with straight and flexible conduits
• Water tightness level: IP 44
• Fits with: WATERTIGHT Courbox, Courline EURO, Spiral EURO, Courflex
TYPE 16 20 20 25 32 40 50For conduits with an ext. Diameter of / mm 16 20 20 25 32 40 50CODE 33-2000... 1-016 2-203 3-209 4-025 5-032 6-040 7-050Installation hole diameter / mm in watertight Courbox 23 23 29 29 37 37 48PACKAGING Bag 10 10 10 10 5 5 5
COLOR GRAY (RAL.7035)
Flexible Connection
• Flexible connection of straight and flexible Courline EURO conduits
• Water tightness level: IP 44
ΤYPE 16 20 25 32 40 50For conduits with an ext. Diameter of / mm 16 20 25 32 40 50CODE 39-2... 0001-016 0002-020 0003-025 0004-032 0005-040 0006-050 Connection Length / mm 135 160 205 280 400 515COLOR GRAY (RAL.7035)
34
Conduit connection, support and cutting accessories
Snap Clip Supports• Installation of straight and flexible conduits
(Wall mounted – Floor mounted)
• Ability to connect and assemble on a rail
• Fits with: Courline EURO, Spiral EURO, Courflex
TYPE 16 20 25 32 40 50For conduits with an ext. Diameter of Ο/ mm 16 20 25 32 40 50CODE 34-21... 001-016 002-020 003-025 004-032 005-040 006-050PACKAGING 100 100 100 100 50 50COLOR GRAY (RAL.7035)
Proposed support installation interval for Courline EURO (+25ο) conduits
Conduit TYPE 16 20 25 32 40 50
Distance / cm 60 60 60 50 70 70
Omega Clip Supports • Installation of straight and flexible conduits
(Roofs – Wall mounted – Floor mounted)
• Ability to connect and assemble on rail
• Fits with: Courline EURO, Spiral EURO, Courflex
TYPE 16 20 25 32For conduits with an ext. Diameter of Ο/ mm 16 20 25 32CODE 41-20001-Κ16 41-20002-Κ20 41-20003-Κ25 41-20004-Κ32PACKAGING 25 25 25 25
COLOR GRAY (RAL.7035)
35
Conduit connection, support and cutting accessories
GLAND Racor Courflex
Support Guide Rail
• Ability to install and assemble multiple supplies
• Fits with: Omega – Snap clip supports
LENGTH / mm 200CODE 35-20001-ΡΑΓCOLOR GRAY (RAL.7035)
• Ability to cut straight and flexible light type conduits
• Plastic grips and ergonomical design for easy cutting even inside installation boxes
• Sharp edges made of stainless steel with opening spring and locking position
LENGTH / mm 140WEIGHT / gr 50CODE 12-20120-SHE
Conduit Cutting Scissors for Light Type Conduits 320N
• Connection of watertight boxes courbox with flexible conduits courflex
• Water tightness lever: ΙΡ 65
• With fixing nut - Metric thread
ΤΥΠΟΣ 12 16 20 25 32For conduits internal Diam Ο/ mm 12 16 20 25 32CODE 33-200... 08-12M 09-16M 10-20M 11-25M 12-32MInstallation hole o mm in courboxwatertight courbox 23 23 28 37 37Mertic - Thread Μ16x1.5 Μ20x1.5 Μ25x1.5 Μ32x1.5 Μ40x1.5PACKAGING 10 10 10 10 5COLOR GREY (RAL.7035)
NEW
36
Couplings • Made of special thermoplastic, self-extinguishing, halogen free material
• Special for the connection of straight and flexible conduits
• Water tightness level: IP 67
• Fits with: Courline EURO Halogen Free, Spiral EURO Halogen Free
TYPE 16 20 25 32 40
For conduits with an ext. Diameter of / mm 16 20 25 32 40
CODE 38-200... 10 - H16 11-H20 12-H25 13-H32 14-H40
PACKAGING Bag 25 25 20 10 •
COLOR GRAY (RAL.7035)
• Made of special thermoplastic, self-extinguishing, Halogen Free and low smoke emission material
• Fixed special bend for the connection of straight and flexible conduits
• Water tightness level: IP 67
• Fits with: Courline EURO Halogen Free, Spiral EURO Halogen Free
TYPE 16 20 25 32 40For conduits with an ext. Diameter of / mm 16 20 25 32 40CODE 39-200... 13-H16 14-H20 15-H25 16-H32 17-H40PACKAGING Bag 10 10 10 5 •
COLOR GRAY (RAL.7035)
90° Bend
Conduit connection, support and cutting accessories
37
Racor Connection Box - Conduit• Made of special thermoplastic, self extinguishing, halogen free and
low smoke emission material
• Connection of Courbox watertight boxes with straight and flexible conduits
• Water tightness level: IP 67
• Fits with: Watertight Courbox, Courline EURO Halogen Free, Spiral EURO Halogen Free
TYPE 16 20 25 32 40 For conduits with an ext. Diameter of Ο/ mm 16 20 25 32 40 CODE 33-200... 10-H16 11-H20 12-H25 13-H32 14-H40 Installation hole diameter Ο/ mm in watertight Courbox 23 23 29 37 37 PACKAGING Bag 10 10 10 5 5
COLOR GRAY (RAL.7035)
• Made of special thermoplastic, self extinguishing, halogen free and low smoke emission material
• Installation of straight and flexible conduits (Wall mounted – Floor mounted)
• Ability to connect and assemble on a rail
• Fits with: Courline EURO Halogen Free, Spiral EURO Halogen Free
TYPE 16 20 25 32 40For conduits with an ext. Diameter of Ο/ mm 16 20 25 32 40CODE 34-210... 10-H16 11-H20 12-H25 13-H32 14-H40PACKAGING 100 100 100 100 100COLOR GRAY (RAL.7035)
Proposed support installation interval for Courline EURO (+25o) conduits
Conduit TYPE 16 20 25 32 40Distance / cm 60 60 60 70 70
Snap Clip Supports
Conduit connection, support and cutting accessories
Courbox | Electrical Installation Elements
Junction Boxes
Junction Boxes Ultra
Switch Boxes Super
Switch Boxes EVO
Connected Switch Boxes FRAME
Switch Boxes ΜΟDUL
NEW
NEW
NEW
NEW
NEW
NEWW
Plasterboard Junction Boxes
Plasterboard Switch Boxes
Switch Boxes D65
Spotlight Boxes
Watertight Junction Boxes IP54
Watertight External Elements IP54
NEW
NEW
40
COURBOX Electrical Instalation Elements
Junction BoxesGENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of hard polymer material
APPLICATIONS• Indoor residential and industrial installations• Cable junction in masonry – Flush installations • Special design of lateral partitions for easy cutting and installation of conduits• Practical cap for easy installation and control• Fits with: Spiral DIN L/T, Courline STRAIGHT L/T, Si Bi, Spiral EURO L/T
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIESProtection rating against solid bodies and water IP 20Glow wire test 6500CMinimum temperature limit - 150CMaximum temperature limit + 900C
CODE TYPE DIMENSIONS (mm) PACKAGING / PIECES08-21008-ROV ROUND N/T – Press-on Lid Ο/ 72 Χ 30 10008-21009-ROV ROUND 100 – Press-on Lid Ο/ 100 Χ 35 6008-21003-075 SQUARE 7.5 x 7.5 – Press-on Lid 75 Χ 75 Χ 33 5008-21001-010 SQUARE 10 x 10 – Screw-on Lid 100 Χ 100 Χ 38 4008-21002-015 SQUARE 10 x 15 – Screw-on Lid 100 Χ 150 Χ 40 30COLOR ORANGE (RAL.2004)
CODE TYPE DESCRIPTION DIMENSIONS (mm) PACKAGING/
PIECES
08-21015-105 ULTRA 105 105 Χ 105 - Screw-on Lid 105 Χ 105 Χ 43 40
08-21016-155 ULTRA 155 155 Χ 105 - Screw-on Lid 155 Χ 155 Χ 43 30
08-21018-153 ULTRA 153 153 Χ 123 - Screw-on Lid 153 Χ 123 Χ 49 20
08-21019-190 ULTRA 190 190 Χ 145 - Screw-on Lid 190 Χ 145 Χ 49 10
COLOR ORANGE (RAL.2004)
41
Junction Boxes Ultra
GENERAL DESCRIPTION
● Non-corrosive. Resistant to impact and pressure
● Made of special hard polymer material
APPLICATIONS
● Indoor residential and industrial installations
● Cable junction in masonry - Flush installations
● Special design of lateral partitions for easy cutting and installation of conduits
● Practical cap for easy installation and control
● Higher capacity to manage multiple supplies
● Fits with: Spiral DIN / EURO -Courline STRAIGHT / EURO - SiBi conduits
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIES
Protection rating against solid bodies and water ΙΡ 20
Glow wire test 650°C
Minimum temperature limit - 15°C
Maximum temperature limit + 70°C
COURBOX Electrical Installation Elements
NEW
42
Switch Boxes SuperGENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of special polymer material
APPLICATIONS• Indoor residential and industrial installations• Switch-socket installation reception in masonry – Flush installations • Ability to connect for multiple configurations (sockets – switches) • Fits with: Spiral DIN L/T, Courline STRAIGHT L/T, SiBi, Spiral EURO L/T
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIESProtection rating against solid bodies and water IP 20Glow wire test 6500CMinimum temperature limit - 150CMaximum temperature limit + 900C
CODE TYPE DIMENSIONS (mm) PACKAGING / PIECES08-21005-SUP SUPER Ο/ 61 x 36 100COLOR ORANGE (RAL.2004)
COURBOX Electrical Instalation Elements
COURBOX Electrical Installation Elements
Switch Boxes EVO
GENERAL DESCRIPTION
● Plastic boxes made of synthetic polymer.
● Non-corrosive, insulating.
APPLICATIONS
● Switch - socket installation recess in masonry - Indoor - Flush Installations.
● They fully combine and cover all types of switches, Single - Simple - Single Frame
● They off er safe and fast Switch - Socket support.
● They fi t with all conduit types: Flexible Spiral - Straight Courline Ε/Τ
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIES
Protection rating against solid bodies and water IP 20
Glow wire test 6500C
Minimum temperature limit -150C
Maximum temperature limit +900C
Dielectric strength 400V
CODE TYPE PACKAGING / PIECES
08-21012-EVO EVO 100
08-21030-EVO SPACER 100
COLOR ORANGE
NEW
43
COURBOX Electrical Instalation Elements
Switch Boxes - FrameGENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of special polymer material
APPLICATIONS• Indoor installations• Switch - socket installation recess in masorny - Flash installations• Ability to connect for multiple configurations (sockets - switches)• Fits with: all types of conduits, Flexible Spiral, Straight Courline L/T
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIESProtection rating against solid bodies and water IP 20Glow wire test 6500 CMinimum temperature limit - 150 CMaximum temperature limit + 900 C
CODE ΤΥPE PACKAGING / PIECES08-21020-COV FRAME 100COLOR BLACK
NEW
44
45
Switch Boxes ΜODUL
GENERAL DESCRIPTION
● Non-corrosive. Resistant to impact and pressure
● Made of special hard polymer material
APPLICATIONS
● Indoor residential and industrial installations
● Switch - socket installation recess in masonry - Flush Installations
● Special design of lateral partitions for easy cutting and installation of conduits
● Ideal installation of electrical - electronic modules
● Fits with: Spiral DIN / EURO -Courline STRAIGHT / EURO - SiBi conduits
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIES
Protection rating against solid bodies and water ΙΡ 20
Glow wire test 650°C
Minimum temperature limit - 15°C
Maximum temperature limit + 70°C
COURBOX Electrical Installation Elements
NEW
CODE TYPE DESCRIPTION DIMENSIONS (mm) MOUNTING PACKAGING/
BASE (mm) PIECES
08-21021-3MO MODUL 3 3 positions 94 Χ 58 Χ 48 83,5 100
08-21022-4MO MODUL 4 4 positions 118 Χ 58 Χ 48 108,5 50
08-21023-6MO MODUL 6 6 positions 171 Χ 58 Χ 48 100 30
COLOR BLUE
COURBOX Electrical Installation Elements
NEW
PROPERTIES
Protection rating against solid bodies and water ΙΡ 3X
Glow wire test 850°C
Minimum temperature limit - 15°C
Maximum temperature limit + 90°C
CODE TYPE INSTALLATION DIAMETER (mm) PACKAGING / PIECES
08-21013-105 105 105 Χ 105 Χ 43 40
08-21014-155 155 105 Χ 155 Χ 43 40
08-21017-220 220 160 Χ 220 Χ 75 6
COLOR YELLOW (RAL. 1021)
Plasterboard Junction Boxes
GENERAL DESCRIPTION
● Non-corrosive. Resistant to impact and pressure
● Made of special hard polymer material
● Flame retardant. Self extinguishing
APPLICATIONS
● Indoor residential and industrial installations
● Recess for installation in plasterboards 7mm to 35mm thick
● Junction of cables
● Special design of lateral partitions for easy cutting and installation of conduits
● Practical cap for easy installation and control
● Fits with: Spiral DIN - Spiral EURO - SiBi - Steel Spiral
APPLICATION STANDARDS: IEC 60670 - 1/2002
46
PROPERTIES
Protection rating against solid bodies and water ΙΡ 3X
Glow wire test 850°C
Minimum temperature limit - 15°C
Maximum temperature limit + 90°C
CODE TYPE INSTALLATION HOLE (mm) PACKAGING/
PIECES
08-21007-PLASTER SINGLE Ο/ 68 100
08-21010-2DL DOUBLE Ο/ 65 Χ 2 60
08-21011-3TR TRIPLE Ο/ 65 Χ 3 40
COLOR YELLOW (RAL.1021)
09-21005-NNT Single CAP 50
COLOR WHITE
COURBOX Electrical Installation Elements
Plasterboard Switch Boxes Single-Double-Triple
GENERAL DESCRIPTION
● Non-corrosive. Resistant to impact and pressure
● Made of special hard polymer material
● Flame retardant. Self extinguishing
APPLICATIONS
● Indoor residential and industrial installations
● Switch - socket recess for installation in plasterboards 7mm to 35mm thick
● Junction with special screw-on cap (single)
●Fits with: Spiral DIN - Spiral EURO - SiBi - Steel Spiral
APPLICATION STANDARDS: IEC 60670 - 1/2002
NEW
47
Switch Boxes D65GENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of special polymer material
APPLICATIONS• Indoor residential and industrial installations• Switch-socket installation recess in masonry – Flush installations • Special for the installation of dimmer switches• With special screw-on cap • Fits with: Spiral DIN L/T, Courline STRAIGHT L/T, SiBi, Spiral EURO L/T
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIESProtection rating against solid bodies and water IP 20Glow wire test 6500 CMinimum temperature limit - 150 CMaximum temperature limit + 900 C
CODE ΤΥPE DIMENSIONS (mm) PACKAGING / PIECES08-21004-ΝΤ D.65 Ο/ 65 Χ 43 100
COLOR ORANGE (RAL.2004)LID 09-21005-ΝΝΤ Srew-on Lid Ο/ 73 50COLOR WHITE
COURBOX Electrical Instalation Elements
48
49
Spotlight Installation BoxesGENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of special polymer material
APPLICATIONS• Indoor residential and industrial installations• Encased in concrete• Recess for the installation of ceiling spotlights R.50 – R.63/80• Special design of lateral partitions for easy cutting and conduits installation• Fits with: SiBi, Spiral EURO M/T, Betosol
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIESProtection rating against solid bodies and water IP 20Glow wire test 6500CMinimum temperature limit - 150CMaximum temperature limit + 900C
CODE TYPE DIMENSIONS (mm) PACKAGING / PIECES29-21001-R50 R.50 Ο/ 74 Χ 108 3029-21002-R63 R.63/80 Ο/ 94 Χ 126 20COLOR BLACK
COURBOX Electrical Instalation Elements
NEW
50
Watertight Junction Boxes IP54 GENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of durable polymer material • Flame retardant. Self extinguishing
APPLICATIONS• Outdoor and indoor residential and industrial installations• Motion installations – Equipment power supply – Lighting • Special design of side caps for easy cutting and installation of conduits - cables• Threaded base for quick installation on Robot M6 nails• Fit with: Racor EURO, Courline EURO, Spiral, EURO, SiBi, Courflex
APPLICATION STANDARDS: IEC 60670 - 1/2002
PROPERTIESProtection rating against solid bodies and water IP 54Glow wire test 8000CMinimum temperature limit - 150CMaximum temperature limit + 900C
CODE TYPE INTERNAL INSTALLATION PACKAGING / DIMENSIONS (mm) HOLES Ο/ mm PIECES32-21001-653 ROUND 65 – Press-on lid* Ο/ 65 Χ 35 4 / 23 6032-21002-804 ROUND 80 – Press-on lid* Ο/ 80 Χ 40 4 / 23 60CODE TYPE INTERNAL DIMENSIONS INSTALLATION PACKAGING / (mm) LxWxH HOLES Ο/ mm PIECES32-20008-654 SQUARE 65 - Screw-on lid* 65 Χ 65 Χ 40 4 / 23 6032-21003-808 SQUARE 80 - Press-on lid* 80 Χ 80 Χ 40 6 / 23 6032-21004-100 SQUARE 100 - Screw-on lid* 100 Χ 100 Χ 50 6 / 29 6032-20005-120 SQUARE 120 - Screw-on lid 120 Χ 80 Χ 50 6 / 29 4032-20006-150 SQUARE 150 - Screw-on lid 150 Χ 110 Χ 70 8 / 29 2432-20007-190 SQUARE 190 - Screw-on lid 190 Χ 140 Χ 70 10 / 37 1232-20008-240 SQUARE 240 - Screw-on lid 240 X 190 X 90 12 / 37 1232-20009-300 SQUARE 300 - Screw-on lid 300 X 220 X 120 12 / 37 632-20010-380 SQUARE 380 - Screw-on lid 380 X 300 X 120 12 / 37 4
COLOR GRAY (RAL.7035) WHITE
ROUND 65 – ROUND 80 – SQUARE 80 – SQUARE, 100 Special Halogen Free types also available
Courbox Watertight Elements of Electrical Installations
51
Watertight External Elements IP54GENERAL DESCRIPTION• Non-corrosive. Resistant to impact and pressure• Made of durable polymer material • Flame retardant. Self extinguishing, AC 250V – 16A• Protection rating against solid bodies and water IP 54
APPLICATIONS• Outdoor and indoor residential and industrial installations• Motion – installations – Lighting • Special design of side cups for easy cutting and installation of conduits max o 20 - cables• Fit with: Courline EURO, Spiral EURO, Courflex
APPLICATION STANDARDS: DIN EN.606691-1 (VDE 0632 TEIL.1): 2003-09 EN.60669-1:1999 + A1:2002
PROPERTIESProtection rating against solid bodies and water ΙΡ 54Glow wire test 800°CMinimum temperature limit - 15°CMaximum temperature limit + 90°C
CODE TYPE DIMENSIONS (mm) PACKAGING/PIECES32-20001-SWI External Switch mechanism. One gang - Two way 65 Χ 77 Χ 50 1032-20002-SWI External Double Switch mechanism 65 Χ 77 Χ 50 1032-20003-PLU Single plug socket 65 Χ 77 Χ 53 1032-20009-PLD External push button 124 Χ 77 Χ 53 632-20004-BUT Button 65 Χ 77 Χ 50 10COLOR GREY (RAL.7035)
Courbox Watertight Elements of Electrical Installations
Distribution channels
Channels
Floor Mounted
Air Conditioning Drainage
GENERAL DESCRIPTION• Straight rigid plastic channels• Made of hard polyvinyl chloride (U-PVC) • Self extinguishing, flame retardant
APPLICATIONS• In residential, industrial and professional spaces• Installations in suspended ceilings• The back of the channels is perforated for easy installation• Cover for practical application and easy installation• Type 100 x 35: System of multiple use channels with flush accessories, easy installation of sockets, switches
APPLICATION STANDARDS: EN 50085-1, EN 50085-2-1
PROPERTIESMinimum temperature limit - 150CMaximum temperature limit + 600CGlow wire test 8000CCOLOR: WHITE (RAL.9016) Length: 2m
DIMENSIONS TYPE CODE PACKAGING TYPE m / PIECES
12 X 13 24-21001-K12 CARTON Box 220/110
20 X 13 24-21002-K20 CARTON Box 126/63
25 X 25 24-21003-K28 CARTON Box 60/30
24-21009-F25 PLASTIC Film 16/8
40 X 30 24-21004-K42 CARTON Box 60/30
24-21010-F30 PLASTIC Film 16/8
40 X 40 24-21005-K42 CARTON Box 60/30
24-21011-F40 PLASTIC Film 16/8
60 X 40 24-21006-K62 CARTON Box 30/15
24-21012-F60 PLASTIC Film 8/4
60 X 60 24-20003-606 PLASTIC Film 12/6
80 X 40 24-21007-K82 CARTON Box 30/15
24-21013-F80 PLASTIC Film 8/4
80 X 60 24-20005-806 PLASTIC Film 12/6
100 X 35 24-21008-102 CARTON Box 32/16
24-21014-F10 PLASTIC Film 8/4
100 X 40 24-20006-100 PLASTIC Film 8/4
100 X 60 24-20007-106 PLASTIC Film 8/4
Channels
Distribution Channels
54
55
GENERAL DESCRIPTION• Straight rigid plastic channels • Made of hard polyvinyl chloride (U-PVC)• Self extinguishing, flame retardant
APPLICATIONS• Floor mounted installations in offices and industrial or professional spaces
APPLICATION STANDARDS: EN 50085-1, EN 50085-2-1
TYPE CODE PACKAGING TYPE m / PIECES60 X 15 24-20010-601 PLASTIC Film 16/8 70 X 18 24-20011-701 PLASTIC Film 16/8
Floor Mounted Distribution Channels
Distribution Channels
Air Conditioning Drainage Channels
GENERAL DESCRIPTION
• Straight rigid plastic channels
• Made of hard polyvinyl chloride (U-PVC)
• Self extinguishing, flame retardant
APPLICATIONS
• Air conditioning unit drainage, operation installations
APPLICATION STANDARDS: EN 50085-1, EN 50085-2-1
TYPE CODE PACKAGING TYPE m / PIECES
75 X 60 24-20009-756 PLASTIC Film 12/6
Support and protection accessories
Cable Ties
Installation Tools Punches
Cable Clips
Terminal Strips
Plugs
Caps
Nail plugs
Socket Protection Caps
Siko Fastening Nails
Panel Filling Flanges
Fix Pin Fastening Nails
Support Strap
Robot M6 Fastening Nails
Nylon CablePuller
DIMENSION / mm A X B CODE WHITE CODE BLACK PACKAGING / PIECES / BAG
140 x 2.5 25-20100-142 25-20101-142 100
160 x 2.5 25-20102-162 25-20103-162 100
200 x 2.5 25-20104-202 25-20105-202 100
250 x 3.6 25-20106-203 25-20107-203 100
250 x 3.6 25-20108-253 25-20109-253 100
290 x 3.6 25-20110-303 25-20111-303 100
200 x 4.8 25-20112-204 25-20113-204 100
250 x 4.8 25-20114-254 25-20115-254 100
290 x 4.8 25-20116-294 25-20117-294 100
360 x 4.8 25-20118-364 25-20119-364 100
360 x 7.6 25-20120-367 25-20121-367 100
CODE WHITE
58
Support & Protection Accessories
Cable Ties
GENERAL DESCRIPTION• High strength plastic cable ties made of polyamide 6/6 (Nylon)• Safe, quick and easy tying of cables, conduits etc.• Self Extinguishing UL 94 V2• Utilization temperature range -400C + 850C • Manufactured in two types: White for usual applications and reinforced Black
for greater resistance and outdoor applications.• COLOR: White (natural) – Black (carbonate black)
APPLICATION STANDARDS: EN.50146/2000
59
Cable Clips
GENERAL DESCRIPTION• Plastic cable clips made of polyolefin with a hardened steel concrete nail• Resistance to chemical and atmospheric agents. Utilization temperature range: -200C +750C• Safe and quick installation of cables, conduits etc.
CODE TYPE DIMENSIONS / mm AxB PACKAGING / PIECES
28-20105-420 4 X 20 flat 100
28-20106-520 5 X 20 flat 100
Support & Protection Accessories
CODE TYPE DIMENSIONS / mm AxB PACKAGING / PIECES28-20107-420 4 X 20 100
28-20108-520 5 X 20 100
28-20109-625 6 X 25 100
28-20110-725 7 X 25 100
28-20111-825 8 X 25 100
28-20112-925 9 X 25 100
28-20113-102 10 X 25 100
28-20114-112 11 X 25 100
28-20115-122 12 X 25 100
28-20116-635 6 X 35 100
28-20117-735 7 X 35 100
28-20118-835 8 X 35 100
28-20119-935 9 X 35 100
28-20120-103 10 X 35 100
28-20121-113 11 X 35 100
28-20122-123 12 X 35 100
28-20123-133 13 X 35 100
28-20124-143 14 X 35 100
28-20125-153 15 X 35 100
28-20126-163 16 X 35 100
28-20127-173 17 X 35 100
28-20128-195 19 X 50 50
28-20129-225 22 Χ 50 50
c D
c
Α
O/
60
GENERAL DESCRIPTION• Plastic plugs made of polyolefin• Resistance to chemical and atmospheric agents.
Utilization temperature range: -200 +750
• Safe and quick installation of all types of screws• Excellent adaptation between screw and installation hole
CODE TYPE DIMENSION /mm PACKAGING / Ο/ Χ Α PIECES28-20002-006 6 6 x 30 10028-20003-007 7 7 x 35 10028-20004-008 8 8 x 40 10028-20005-010 10 10 x 50 10028-20006-012 12 12 x 60 5028-20007-014 14 14 x 75 40
Installation instructions
Support & Protection Accessories
Plugs
Plugs With Nailed ScrewGENERAL DESCRIPTION• Plastic plugs made of nylon • Incorporated ‘nailed-in’ chromium screw CODE TYPE DIMENSION / mm PACKAGING / Ο/ X A PIECES28-20010-640 SP 6x40 6 x 40 10028-20011-655 SP 6x55 6 x 55 10028-20012-855 SP 8x55 8 x 55 100
Installation instructions
61
Support & Protection Accessories
GENERAL DESCRIPTION• Hardened steel concrete nail coated with plastic insulation• Special for installation of NYFY cables (flat)
CODE TYPE PACKAGING / PIECES DIMENSIONS / mm BAG – CARTON BOX Ο/ X A
28-20200-PIN 2 x 12 100 / 1000
GENERAL DESCRIPTION• Hardened steel concrete nail for installations in concrete, plaster, etc.
CODE TYPE DIMENSIONS / mm Ο X L PACKAGING / PIECES28-20061-618 Μ6x8x18 10028-20062-625 Μ6x8x25 10028-20063-630 Μ6x8x30 100
SIKO Fastening Nails With Plastic Coating
GENERAL DESCRIPTION• Special hardened steel concrete nail for installations in concrete, plaster, etc.
CODE TYPE DIMENSIONS /mm PACKAGING / Ο/ X A PIECES
28-20051-414 FP 14 4 x 14 10028-20052-418 FP 18 4 x 18 10028-20053-422 FP 22 4 x 22 100
Fix Pin Fastening Nails
Robot M6 Fastening Nails
Installation Tools – Punches
FixPin PUNCH with capCode : 28-20050-ZOU
FixPin PUNCHCode : 28-20049-ZFP
Robot M6 PUNCH Code: 28-20048-RM6
GENERAL DESCRIPTION• Plastic clamps for junctions and connections of cables in 12 pole bars • Hard bronze connectors• Utilization temperature range: -50 C +850 C • Electrical insulation: 380 V• COLOR: White
CODE TYPE PACKAGING / PIECES BAG /CARTON BOX
12-20001-004 4 10 / 25012-20002-006 6 10 / 25012-20003-010 10 10 / 25012-20004-016 16 10 / 100
TYPE DIMENSIONS / mm Max. connection capacity Α 12 pole B C,Ο/ D, Ο/ Multi-branch, single branch cable4 92 7 2 3 4 mm2
6 109 8.5 3.2 3.5 6 mm2
10 129.5 10 3.2 4 10 mm2
16 171 14 3.2 6 16 mm2
Caps For Protection of Cable Connections
GENERAL DESCRIPTION
• Plastic caps made of polyolefin with internal bronze spiral guide
• Offers protection and safety to the junction – connection of cables
• Application temperature range: -200 C +750 C
CODE TYPE Connection capacity PACKAGING / PIECES
Multi-branch, BAG / CARTON BOX single branch cable
12-20101-C12 1.5 - 2.5 1.5 - 2.5 mm2 100 / 5,000
12-20102-C46 4-6 4 - 6 mm2 100 / 2,000
12-20103-C10 10 10 mm2 50 / 1,000
Terminal Strips
Support & Protection Accessories
c D
62
GENERAL DESCRIPTION• Plastic socket protection caps made of polyolefin• Quick installation and extraction with the use of special accessory only • Offers protection and safety for the socket in order
to prevent access to it
CODE PACKAGING / PIECES BAG / CARTON BOX
12-20100-COV 10 / 1000
Support & Protection Accessories
Panel Filling Flange
CODE PACKAGING / PIECES BAG / CARTON BOX
12-20110-FLP 300
Support Strap
GENERAL DESCRIPTION• Support strap made of high strength synthetic material • Ideal installation with Fix Pin FASTENING NAILS • Easy installation of conduits – cables
CODE PACKAGING / PIECES BAG / CARTON BOX28-20047-IMA 5 / 300
Nylon Cable Puller• Nylon Cable Puller with hole and spring for easy and quick cables
penetration in the conduits
CODE LENGHT/m DIMENSIONS Ο/ /mm PACKAGING / PIECES28-20030-45Μ 5 3 12028-20031-410 10 3 8028-20032-415 15 3 60COLOR GREY
Socket Protection Caps
63
Technical Guide
1. Product Certification
2. ΕΝ 61386 New European Standards for Electrical Installation Conduits
3. IP Protection Rating
4. Halogen Free
64
Technical Guide
65
1. Product Certification
All our products comply with European Regulation requirements on safety and reliability. Low voltage Directive 73/23 EEC and 89/106 EEC – 92/59 EEC.
National provisions: Ministerial Decision 470/1.4.85 (Official Ga-zette Issue 183/B/85) – Ministerial Decision B6467/608/18.3.88, Ministerial Decision 1617/5052/22.12.94 (Official Gazette Issue 922/B/94).
The members of CENELEC (European Committee for Electro-technical Standardi-zation) are obliged to comply with the re-quirements of internal regulations specifying the terms accord-ing to which the status of National Standard is awarded to this European Standard without any modification.
Courbi products dispose of a CE declaration of conformity and all the necessary certifications based on the European Stand-ards, through strict and systematic controls at a private owned laboratory, as well as through permanent cooperation with in-dependent certified laboratories (ELKEPYH – KDEP).
Our Company’s Policy is to provide our customers with high
quality products. This quality is ensured by the implementation of a random control system with reference to the requirements of European standards, in cooperation with the certified inde-pendent body: Hellenic Center of Electric Material Quality Con-trol, ELKEPHY).
Within the frame of the quality policy, all the products distrib-uted by our Company are accompanied by all the required cer-tificates by the corresponding certification bodies.
Technical Guide
2. ΕΝ 61386 New European Standards for Cable Management (electrical installation) Conduits
New European standards on control, concerning the management of cables within conduits – pipes have taken effect since 22/06/2004. These are based on and will gradually replace the current EN.50086-1/994 standards that will remain in force until 2008.
• ΕΝ. 61386-1 Conduit systems for cable management - Part 1: General requirements
The present Standard specifies the requirements and tests for conduit systems, including conduits and con-duit fittings for the protection and arrangement of insulated conduits and/or cables in electrical installa-tions or in communication systems up to 1000 V of alternating current and/or 1500 V of direct current. The present Standard applies to metallic, non-metallic and composite conduit systems, including cone threaded or non-cone threaded inlets that terminate the system.
• ΕΝ. 61386 - 21 Particular requirements - Part 21: Rigid Conduit systems
The present Standard specifies the requirements and tests for straight, rigid conduits, including conduit fittings for the protection and arrangement of insulated conduits and/or cables in electrical installations or in communication systems.
• ΕΝ. 61386 - 22 Particular requirements - Part 22: Pliable Conduit systems
The present Standard specifies the requirements and tests for semi-rigid, pliable conduits, including conduit fittings for the protection and arrangement of insulated conduits and/or cables in electrical installations or in communication systems.
• ΕΝ. 61386 - 23 Particular requirements - Part 23: Flexible Conduit systems
The present Standard specifies the requirements and tests for flexible conduits, including conduit fittings for the protection and arrangement of insulated conduits and/or cables in electrical installations or in com-munication systems.
• ΕΝ. 61386 - 24 Particular requirements - Buried under ground Conduit systems
The present Standard specifies the requirements and tests for underground conduits, including conduit fittings for the protection and arrangement of insulated conduits and/or cables in electrical installations or communication systems.
66
Technical Guide
Classification of conduits according to standard EN 61386-16-1 According to the European standards, electrical installation conduits are characterized by a classification
code format, based on their mechanical properties produced by a series of laboratory tests. The conduit can be marked by a classification code including at least the first 4 digits of that code where
each digit represents a different property.
1st DIGIT: Resistance to compression 2nd DIGIT: Resistance to impact 3rd DIGIT: Minimum operating temperature 4th DIGIT: Maximum operating temperature
In particular, the requirements regarding mechanical properties of conduits according to EN 61386-1 are as follows:
CLASSIFICATION CONDUITS COMPRESSION FORCE N (Newton +4% -0%) 1 Very Light 125 2 Light 320 3 Medium 750 4 Heavy 1250 5 Very Heavy 4000
COMPRESSION TEST (EN 61386-1, § 10.2) Conduit samples, (200±5) mm long, are placed on a flat metallic base and an intermediate steel piece is
placed in the middle of the sample (Figure 1); a steadily increasing compressive force is applied on the steel piece over a period of 30 sec, reaching the values given in the above table. Once applied for (60±2) sec, the external diameter of the sample must be measured without removing the force.
The difference between the initial diameter of the conduit before the test and the compressed diameter must not exceed 25% of the initial external diameter.
The force and the intermediate piece are removed and 60 sec after removal, the external diameter of the compressed sample must not exceed 10% of its initial external diameter. The samples must not have cracks that are visible with the naked eye.
67
Technical Guide
2nd DIGIT: Resistance to impact (EN 61386-1, § 6.1.2)
CLASSIFICATION CONDUITS HAMMER MASS FALL HEIGHT Kg (+1 - 0%) mm ±1% 1 Very Light 0,5 100 2 Light 1,0 100 3 Medium 2,0 100 4 Heavy 2,0 300 5 Very Heavy 6,8 300
IMPACT TEST (ΕΝ 61386-1 § 10.3) Twelve samples of conduits, (200±5) mm long, or twelve conduit fittings are submitted to an impact test by
the apparatus shown in (Figure 2). When the samples reach the specified temperature (minimum operating temperature) they are placed on the steel base of the apparatus. The hammer must be left to fall once on each sample. The hammer’s mass and the fall height must be those shown in the above table.
After the test, at least 9 samples must not have cracks that are visible with the naked eye, or distortions that prevent their normal use.
68
69
3rd DIGIT: Minimum operating temperature (EN 61386-1, § 6.2.1, Table 1)
CLASSIFICATION TEMPERATURE 0C 1 +5 2 -5 3 -15 4 -25 5 -45
4th DIGIT: Maximum operating temperature (EN 61386-1, § 6.2.2, Table 2) CLASSIFICATION TEMPERATURE 0C 1 60 2 90 3 105 4 120 5 150 6 250 7 400
Detailed conduit properties according to EN 61386-1
5. BENDING STRENGTH (EN 61386-1 § 6.1.3)
CLASSIFICATION CONDUIT TYPE 1 Rigid 2 Pliable 3 Pliable / Self restoration 4 Flexible
6. TENSILE FORCE (ΕΝ 61386-1 § 6.1.4 / 10.7)
CLASSIFICATION TYPE CONDUIT TENSILE STRESS N (Newton +2% - 0%)
1 Very Light 100 2 Light 250 3 Medium 500 4 Heavy 1000 5 Very Heavy 2500
Technical Guide
7. SUSPENDED LOAD BEARING CAPACITY (ΕΝ 61386-1 § 6.1.5 / 10.8)
CLASSIFICATION FITTINGS LOAD DURATION N (Newton +2% - 0%) h / +15-0min 1 Very Light 20.0 48 2 Light 30.0 48 3 Medium 150.0 48 4 Heavy 450.0 48 5 Very Heavy 850.0 48
8. ELECTRICAL CHARACTERISTICS (ΕΝ 61386-1 § 6.3 - 6.3.1 - 6.3.2)
CLASSIFICATION Conduits with electrical continuity characteristics Conduits with electrical insulation characteristics
9. RESISTANCE TO EXTERNAL IMPACTS (ΕΝ 61386-1 § 6.4)9a. Protection according to standard EN 60529
REQUIREMENT min/ PROTECTION RATING Entrance of SOLID objects – (EN 61386-1, § 6.4.1) IP3X Inflow of WATER – (EN 61386-1, § 6.4.2) IP X0
9b. Protection against corrosion – (EN 61386-1, § 6.4.3 Table 10) CLASSIFICATION OFFERED PROTECTION EXAMPLE 1 Low protection inside & outside Primer coating
2 Average protection inside & outside Electric stove enamel Electro-galvanized plate Air drying paint
3 Average/High protection of composites Electric stove enamel Inside: Class 2 – Outside: Class 4 Diffusion
4 High protection inside & outside Coating by hot immersion in Zn Diffusion Stainless steel
10. RESISTANCE TO SPREADING OF FIRE (ΕΝ 61386-1 § 6.5 ) REQUIREMENT
Flame retardant conduits – (EN 61386-1, § 6.5.1)
Non flame retardant conduits – (EN 61386-1, § 6.5.2)
Technical Guide
70
71
11. THERMAL PROPERTIES (ΕΝ 61386-1 § 12)
• Resistance to the spreading of flames. Test (ΕΝ 61386-1 § 12.1)
MATERIAL THICKNESS mm MATERIAL THICKNESS mm FLAME APPLICATION TIME over under sec (+1-0) - 0,5 15 0,5 1,0 20 1,0 1,5 25 1,5 2,0 35 2,0 2,5 45 2,5 3,0 55 3,0 3,5 65 3,5 4,0 75 4,0 4,5 85 4,5 5,0 130 5,0 5,5 200 5,5 6,0 300 6,0 6,5 500
Samples of non-metallic and composite conduits must be checked by the application of a flame of 1kW (Bunsen Burner – EN 60695-2-4/1).
A conduit sample, (675 ± 10) mm long, is placed vertical-ly in the apparatus shown in (Figure 3). The test is carried out on 3 samples. The flame is applied to the samples according to the above Table and then it is removed. The sample is considered to have passed the test if it is not ignited.
The sample is considered to have passed the test when it is burned or ruined without being burned and when after the burning has stopped, there is no indication of burning or scorching within 50 mm of the upper and lower ends of the clamps. If the sample is burned, it must be considered to have failed the test if the burning con-tinues 30 sec after the removal of the flame. If the paper tissue under the sample is ignited, the sample must be considered to have failed the test.
Technical Guide
• Heat resistance. Test – (EN 61386-1, § 12.2) The load of this test must be of the same classification as the compression strength test corresponding to
the maximum operating temperature.
Load for heating test
CLASSIFICATION CONDUITS MASS – WEIGHT kg +1 - 0% 1 Very Light 0.5 2 Light 1.0 3 Medium 2.0 4 Heavy 4.0 5 Very Heavy 8.0
Samples of conduits, (100±5) mm long, are kept in a hot chamber together with the test appara-tus (Figure 4) for 4h±5min at the highest operat-ing temperature stated.
Then, each sample is placed in the appa-ratus to-gether with the corresponding mass-weight and they remain in the hot chamber for 24h±15min.The sample together with the load must be left to cool-off at room temperature.
Then, the load is removed. Immediately after re-moval, it must be possible to pass a suitable cali-brator through the conduit with the same load and without initial speed, with the sample in ver-tical position.
Technical Guide
72
73
3. ΙΡ Protection Rating
Classification of electrical material according to EN 60529
According to the European standards, the protection rating of the electrical material of electrical installation boxes, fittings and conduits is specified by the IP protection index, that comprises 2 digits where each digit represents a different property of protection against external effects.
1st DIGIT: 0-6 Protection against penetration of solid particles. 2nd DIGIT: 0-8 Protection against penetration of liquids.
GLOW WIRE TEST (EC 695 2-1)The glow wire must be applied once to each sample at the most unfavourable utilisation position intended (with the test surface in vertical position). The sample is considered to have passed the test when there is no visible flame or prolonged glow or when the flames or glow are extinguished within 30 sec from the removal of the glow wire.
TEST APPARATUS WIRE GLOW TEMPERATURES
650οC 750οC 850οC
Technical Guide
4. Halogen Free Products
1. WHY USE HALOGEN FREE PRODUCTS
Halogen free and some other special products, are necessary or even imperative when the primary goal is to safe-guard human life and there is a pressing need to protect property.
2. HALOGEN FREE PRODUCT APPLICATIONS
Halogen free products are gradually and increasingly applied where a potential fire may have fatal results, e.g. Public buildings, underground railways, airplanes, ships, etc., as well as other equipment systems, the destruc-tion of which may have tremendous financial consequences.
3. HALOGEN FREE PRODUCT PROPERTIES
1. Flame retardation2. Low smoke emission 3. Zero toxic or corrosive gas emissions.
4. RESULTS OF USE OF HALOGEN FREE PRODUCTS
1. High resistance to the initiation of fire or restriction of its propagation. 2. Increase of visibility and easier identification of escape routes during a fire incident. 3. Low toxicity fields during the escape from closed spaces, in case of fire. 4. Safety of equipment and installations against the emission of toxic or corrosive gases.
Technical Guide
74