25
PLAN SECTION VERTICAL SECTION Structural Rail Structural Rails Design for lateral loads and for gravity load of façade system. System weights are provided in current product data sheets. Steelwork Tolerances The permissible steelwork tolerance between the bearing planes of adjacent supports is spacing/600. Rev: Drawing Nº. Drawing Title: Drawn By: Project: Date: By Kingspan System: © Kingspan 2013 Fax: 01352 710 161 Tel: 01352 716 100 Flintshire. CH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: [email protected] Website: www.kingspanbenchmark.com BENCHMARK Dri-Design and QuadCore Karrier System Layout AE 07/04/2017 DD QK Vt Rail 001 0 0 100mm BENCHMARK QuadCore Karrier - Vertically laid. Thickness to meet U value Panel fasteners. Frequency subject to applied loads BENCHMARK QuadCore Karrier - Vertically laid. Thickness to meet U value Panel fasteners. Frequency subject to applied loads 1100 34 34 BENCHMARK Dri-Design Cassette BENCHMARK SVG2540 PVC Foam Tape BENCHMARK Dri-Design Rivet centres subject to wind loads and cassette width BENCHMARK Dri-Design Cassette Factory Applied Weatherseal Site Applied Vapour Seal 16
Transcript
Page 1: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

PLAN SECTION

VERTICAL SECTION

Structural Rail

Structural RailsDesign for lateral loads and for gravity load offaçade system. System weights are provided incurrent product data sheets.

Steelwork TolerancesThe permissible steelwork tolerance betweenthe bearing planes of adjacent supports isspacing/600.

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

System Layout

AE 07/04/2017

DD QK Vt Rail 001 0

0 100mm

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

BENCHMARK QuadCore Karrier- Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

1100

34

34

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARK Dri-Design Rivetcentres subject to wind loadsand cassette width

BENCHMARKDri-Design Cassette Factory Applied Weatherseal

Site Applied Vapour Seal

16

Page 2: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Drip Detail

AE 07/04/2017

DD QK Vt Rail 002 0

0 100mm

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

Air seal - Gun grade sealantat male joint

Cladding rail

Air seal - Continuous beadof gun grade sealant

Ground floor slab

VCL - EPDM Membrane bonded

to rear of panel and DPM

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARKDri-Design Rivet

BENCHMARKDri-Design 1/2" FaceSmall J ExtrusionRef: BMDD-SMALLJ

30

Page 3: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Drip Detail

AE 07/04/2017

DD QK Vt Rail 002F 0

0 100mm

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

Air seal - Gun grade sealantat male joint

Cladding rail

Air seal - Continuous beadof gun grade sealant

Ground floor slab

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARKDri-Design Rivet

BENCHMARKDri-Design End Trim

VCL - EPDM Membrane bonded

to rear of panel and DPM

35

Page 4: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Drip Detail

AE 07/04/2017

DD QK Vt Rail 002E 0

0 100mm

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

Air seal - Gun grade sealantat male joint

Cladding rail

Air seal - Continuous beadof gun grade sealant

Ground floor slab

VCL - EPDM Membrane bonded

to rear of panel and DPM

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARK Dri-DesignStart/Cut ExtrusionRef: BMDD-STARTCUT

BENCHMARK Dri-DesignExtrusion GasketRef: BMDD-GASKET

BENCHMARKDri-Design Rivet

BENCHMARK Dri-DesignExtrusion Face CapRef: BMDD-JCAP

BENCHMARK Dri-DesignJ Extrusion BackRef: BMDD-JBACK

37

Page 5: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

External Corner

AE 07/04/2017

DD QK Vt Rail 004 0

Cladding Rail

Cla

ddin

g R

ail

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Air Seal - Continuous beadof gun grade sealant

4mm dia butyl rubber seal

Panel fasteners at 500mmcr/s subject to applied loads

Fire rated canister applied insulation

Air Seal - Continuous beadof gun grade sealant

4mm dia butyl rubber seal

Panel fasteners at 500mmcr/s subject to applied loads

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Internal cleader angle bysteelwork sub-contractor.Joints air sealed with vinylfaced butyl rubber sealing strip

0 100mm

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design Corner Cassette(Site measure)

BENCHMARKDri-Design Cassette

0.7mm thk XL Forteexternal corner trim

25mm PIR InsulationBoard

Page 6: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

External Corner

AE 07/04/2017

DD QK Vt Rail 004E 0

Cladding Rail

Cla

ddin

g R

ail

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Air Seal - Continuous beadof gun grade sealant

Panel fasteners at 500mmcr/s subject to applied loads

Fire rated canister applied insulation

Air Seal - Continuous beadof gun grade sealant

4mm dia butyl rubber seal

Panel fasteners at 500mmcr/s subject to applied loads

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Internal cleader angle bysteelwork sub-contractor.Joints air sealed with vinylfaced butyl rubber sealing strip

0 100mm

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design Cassette

External Closure Angle Flashingsealed to face of both panels

25mm PIR Insulation Board

BENCHMARK Dri-DesignOutside Corner Extrusion BackRef: BBDD-OSCORNERBK

Site trim cassette

BENCHMARK Dri-DesignStart/Cut ExtrusionRef: BMDD-STARTCUT

BENCHMARK Dri-DesignOutside Corner Extrusion CapRef: BMDD-OSCORNERCAP

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARKDri-Design Rivet

16

16

Page 7: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Internal Corner

AE 07/04/2017

DD QK Vt Rail 005 0

0 100mm

Fire rated canisterapplied insulation

Panel fasteners at500mm maximum cr/s

Air seal - Continuous beadof gun grade sealant

0.7mm thk XL Forteinternal corner trim BENCHMARK QuadCore

Karrier - Vertically laid.Thickness to meet U value

4mm dia butyl rubber seal

Internal cleader angle bysteelwork sub-contractor.Joints air sealed with vinylfaced butyl rubber sealing strip

Cladding Rail

Cla

ddin

g R

ail

Panel fasteners at 500mm maximum cr/s

Air seal - Continuous bead of gun grade sealant

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design Cassette

16

Page 8: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Internal Corner

AE 07/04/2017

DD QK Vt Rail 005E 0

0 100mm

Fire rated canisterapplied insulation

Panel fasteners at500mm maximum cr/s

Air seal - Continuous beadof gun grade sealant

External Closure Angle Flashingsealed to face of both panels

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Internal cleader angle bysteelwork sub-contractor.Joints air sealed with vinylfaced butyl rubber sealing strip

Cladding Rail

Cla

ddin

g R

ail

Panel fasteners at 500mm maximum cr/s

Air seal - Continuous bead of gun grade sealant

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design Cassette

BENCHMARK Dri-DesignInside Corner Extrusion BackRef: BBDD-ISCORNERBK

Site trim cassette

BENCHMARK Dri-DesignStart/Cut ExtrusionRef: BMDD-STARTCUT

BENCHMARK Dri-DesignInside Corner Extrusion CapRef: BMDD-ISCORNERCAP

BENCHMARKSVG2540 PVC Foam Tape

Page 9: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Internal finish to

Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

Window by Others

VCL - Continuous membrane

by window installer

BENCHMARKDri-Design Cassette

Site trim cassette

BENCHMARK Dri-DesignStart/Cut Extrusion Ref:BMDD-STARTCUT

BENCHMARK Dri-DesignExtrusion Gasket Ref:BMDD-GASKET

BENCHMARK Dri-DesignExtrusion Face Cap Ref:BMDD-JCAP

BENCHMARK Dri-DesignJ Extrusion Back Ref:BMDD-JBACK

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Sill

AE 07/04/2017

FC FF DD QK Vt Rail 007E 0

0 100mm

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

VCL - Continuous bead

of gun grade sealant

Weather seal by Window Installer

Window Sill by Window Installer

Panels typically fixed at500mm centres, subject towind load

VCL - Continuous membrane

around window opening by

facade contractor

(Special care at corners)

25mm thick PIR board insulation

Page 10: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Sill

AE 07/04/2017

FC FF DD QK Vt Rail 007F 0

0 100mm

Internal finish to

Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

Window by Others

VCL - Continuous membrane

by window installer

BENCHMARKDri-Design Cassette

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

VCL - Continuous bead

of gun grade sealant

Panels typically fixed at500mm centres, subject towind load

VCL - Continuous membrane

around window opening by

facade contractor

(Special care at corners)

Weather seal by Window Installer

Window Sill by Window Installer

25mm thick PIR board insulation

Page 11: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Sill

AE 07/04/2017

FC FF DD QK Vt Rail 007 0

0 100mm

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

VCL - Continuous bead

of gun grade sealant

Weather seal by Window Installer

Window Sill by Window Installer

Panels typically fixed at500mm centres, subject towind load

Internal finish to

Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

Window by Others

VCL - Continuous membrane

around window opening by

facade contractor

(Special care at corners)

VCL - Continuous membrane

by window installer

25mm thick PIR board insulation

BENCHMARKDri-Design Cassette

Page 12: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Head

AE 07/04/2017

DD QK Vt Rail 008 0

0 100mm

VCL - Continuous bead

of gun grade sealant

Weather seal by Window Installer

Internal finish to

Architects Design

Window support angle/plate

by Window Installer

Fire rated canister

applied insulation by

Window Installer

Window by Others

VCL - Continuous membrane

by window installer

25mm thick PIR board insulation

VCL - Continuous membrane

around window opening by

facade contractor

(Special care at corners)

Inner Window Trim

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARKDri-Design Rivet

BENCHMARKDri-Design 1/2" FaceSmall J ExtrusionRef: BMDD-SMALLJ

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

Gun grade sealantto panel joint

Panels typically fixed at500mm centres, subject towind load

Page 13: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Weather seal by Window Installer

Internal finish to

Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

Window by Others

VCL - Continuous membrane

by window installer

25mm thick PIR board insulation

VCL - Continuous membrane

around window opening by

facade contractor

(Special care at corners)

Inner Window Trim

BENCHMARKDri-Design End Trim

BENCHMARKDri-Design Cassette

VCL - Continuous bead

of gun grade sealant

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

Panels typically fixed at500mm centres, subject towind load

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Head

AE 07/04/2017

DD QK Vt Rail 008F 0

0 100mm

Page 14: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Weather seal by Window Installer

Window support

angle/plate by Window

Installer

Fire rated canister applied

insulation by Window

Installer

Window by Others

25mm thick PIR board insulation

Inner Window Trim

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARK Dri-DesignStart/Cut ExtrusionRef: BMDD-STARTCUT

BENCHMARK Dri-DesignExtrusion GasketRef: BMDD-GASKET

BENCHMARKDri-Design Rivet

BENCHMARK Dri-DesignExtrusion Face CapRef: BMDD-JCAP

BENCHMARK Dri-DesignJ Extrusion BackRef: BMDD-JBACK

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Head

AE 07/04/2017

DD QK Vt Rail 008E 0

0 100mm

VCL - Continuous bead

of gun grade sealant

Internal finish to

Architects Design

VCL - Continuous

membrane by window

installer

VCL - Continuous

membrane around window

opening by facade

contractor

(Special care at corners)

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

Panels typically fixed at500mm centres, subject towind load

Page 15: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Jamb

AE 07/04/2017

DD QK Vt Rail 009 0

0 100mm

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

VCL - Continuous bead

of gun grade sealant

Weather seal by Window Installer

Internal finish to Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

Window by Others

VCL - Continuous membrane

by window installer

25mm thick PIR board insulation

VCL - Continuous membrane around

window opening by facade contractor

(Special care at corners)

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design Rivet

Inner Window Trim

Panels typically fixed at 500mmcentres, subject to wind load

Page 16: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design End Trim

Site trim cassette

Weather seal by Window Installer

Window by Others

25mm thick PIR board insulation

Inner Window Trim

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Jamb

AE 07/04/2017

DD QK Vt Rail 009F 0

0 100mm

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

VCL - Continuous bead

of gun grade sealant

Internal finish to Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

VCL - Continuous membrane

by window installer

VCL - Continuous membrane around

window opening by facade contractor

(Special care at corners)

Panels typically fixed at 500mmcentres, subject to wind load

Page 17: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

BENCHMARKDri-Design Cassette

Weather seal by Window Installer

Window by Others

25mm thick PIR board insulation

Inner Window TrimSite trim cassette

BENCHMARK Dri-Design Start/CutExtrusion Ref: BMDD-STARTCUT

BENCHMARK Dri-DesignExtrusion Gasket Ref: BMDD-GASKET

BENCHMARK Dri-DesignExtrusion Face Cap Ref: BMDD-JCAP

BENCHMARK Dri-DesignJ Extrusion Back Ref: BMDD-JBACK

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

VCL - Continuous bead

of gun grade sealant

Internal finish to Architects Design

Window support angle/plate

by Window Installer

Fire rated canister applied

insulation by Window Installer

VCL - Continuous membrane

by window installer

VCL - Continuous membrane around

window opening by facade contractor

(Special care at corners)

Panels typically fixed at 500mmcentres, subject to wind load

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Window Jamb

AE 07/04/2017

DD QK Vt Rail 009E 0

0 100mm

Page 18: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Curtain Wall Head

AE 07/04/2017

DD QK Vt Rail 012 0

0 100mm

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARKDri-Design Rivet

BENCHMARKDri-Design 1/2" FaceSmall J ExtrusionRef: BMDD-SMALLJ

Curtain walling system

by Others

VCL - Continuous bead of

gun grade sealant

Insulation by Curtain

Wall Installer

VCL by Curtain Wall Installer

Weather seal by

Curtain Wall Installer

Internal finish to

Architects design

VCL - Continuous membrane

around opening by facade

contractor

(Special care at corners)

Gun grade sealantto panel joint

Panels typically fixed at500mm centres, subject towind load

Page 19: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design End Trim

Curtain walling system

by Others

Insulation by Curtain

Wall Installer

VCL by Curtain Wall Installer

Weather seal by

Curtain Wall Installer

Internal finish to

Architects design

VCL - Continuous membrane

around opening by facade

contractor

(Special care at corners)

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

VCL - Continuous bead of

gun grade sealant

Gun grade sealantto panel joint Panels typically fixed at

500mm centres, subject towind load

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Curtain Wall Head

AE 07/04/2017

DD QK Vt Rail 012F 0

0 100mm

Page 20: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Curtain walling

system by Others

Insulation by Curtain

Wall Installer

VCL by Curtain

Wall Installer

Weather seal by

Curtain Wall Installer

Internal finish to

Architects design

VCL - Continuous membrane

around opening by facade

contractor

(Special care at corners)

BENCHMARKDri-Design Cassette

BENCHMARKSVG2540 PVC Foam Tape

BENCHMARK Dri-DesignStart/Cut ExtrusionRef: BMDD-STARTCUT

BENCHMARK Dri-DesignExtrusion GasketRef: BMDD-GASKET

BENCHMARKDri-Design Rivet

BENCHMARK Dri-DesignExtrusion Face CapRef: BMDD-JCAP

BENCHMARK Dri-DesignJ Extrusion BackRef: BMDD-JBACK

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

Air seal - Gun gradesealant at male joint

VCL - Continuous bead of

gun grade sealant

Gun grade sealantto panel joint

Panels typically fixed at500mm centres, subject towind load

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Curtain Wall Head

AE 07/04/2017

DD QK Vt Rail 012E 0

0 100mm

Page 21: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Curtain Wall Jamb

AE 07/04/2017

DD QK Vt Rail 013 0

0 100mm

Weather seal by

Curtain Wall Installer

Curtain walling system by Others

Insulation by Curtain Wall Installer

VCL by Curtain Wall Installer

Internal finish to Architects design

BENCHMARKDri-Design Cassette

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

VCL - Continuous bead

of gun grade sealant

VCL - Continuous membrane around

window opening by facade contractor

(Special care at corners)

Panels typically fixed at 500mmcentres, subject to wind load

Page 22: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Weather seal by

Curtain Wall Installer

BENCHMARKDri-Design Cassette

BENCHMARKDri-Design End Trim

Site trim cassette

BENCHMARKSVG2540 PVC Foam Tape

Curtain walling system by Others

Insulation by Curtain Wall Installer

VCL by Curtain Wall Installer

Internal finish to Architects design

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

VCL - Continuous bead

of gun grade sealant

VCL - Continuous membrane around

window opening by facade contractor

(Special care at corners)

Panels typically fixed at 500mmcentres, subject to wind load

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Curtain Wall Jamb

AE 07/04/2017

DD QK Vt Rail 013F 0

0 100mm

Page 23: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Weather seal by

Curtain Wall Installer

BENCHMARKDri-Design Cassette

BENCHMARK Dri-Design Start/CutExtrusion Ref: BMDD-STARTCUT

BENCHMARK Dri-DesignExtrusion Gasket Ref: BMDD-GASKET

BENCHMARK Dri-DesignExtrusion Face Cap Ref: BMDD-JCAP

BENCHMARK Dri-DesignJ Extrusion Back Ref: BMDD-JBACK

BENCHMARKSVG2540 PVC Foam Tape

Site trim cassette

Curtain walling system by Others

Insulation by Curtain Wall Installer

VCL by Curtain Wall Installer

Internal finish to Architects design

BENCHMARK QuadCore Karrier -Vertically laid.Thickness to meet U value

VCL - Continuous bead

of gun grade sealant

VCL - Continuous membrane around

window opening by facade contractor

(Special care at corners)

Panels typically fixed at 500mmcentres, subject to wind load

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Curtain Wall Jamb

AE 07/04/2017

DD QK Vt Rail 013E 0

0 100mm

Page 24: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Parapet

AE 07/04/2017

DD QK Vt Rail 006 0

0 100mm

Kingspan Topdek InsulatedMembrane Roof Panel.Thickness to meet U value

Kingspan Topdek InsulatedMembrane Roof Panel.Thickness to meet U value

PIR board insulation

Membrane taken over parapet

Aluminium parapet coping

Air seal - Gun grade sealant atmale joint

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

Air seal - Continuous bead ofgun grade sealant

BENCHMARKDri-Design Cassette

Kingspan Topdek InsulatedMembrane Roof Panel.Thickness to meet U value

BENCHMARKDri-Design Cassette

Page 25: 0 100mm -   · PDF fileCH8 7GJ Greenfield, Holywell Greenfield Business Park No.2 Technical: 0800 970 9036 Email: technical@kingspanbenchmark.com Website:

Rev:Drawing Nº.

Drawing Title:

Drawn By:

Project:

Date:By Kingspan

System:

© Kingspan 2013

Fax: 01352 710 161Tel: 01352 716 100Flintshire. CH8 7GJ Greenfield, HolywellGreenfield Business Park No.2

Technical: 0800 970 9036Email: [email protected]: www.kingspanbenchmark.com

BENCHMARK Dri-Design and QuadCore Karrier

Parapet

AE 07/04/2017

DD QK Vt Rail 006E 0

0 100mm

Kingspan Topdek InsulatedMembrane Roof Panel.Thickness to meet U value

Kingspan Topdek InsulatedMembrane Roof Panel.Thickness to meet U value

PIR board insulation

Membrane taken over parapet

Aluminium parapet coping

Air seal - Gun grade sealant atmale joint

BENCHMARK QuadCoreKarrier - Vertically laid.Thickness to meet U value

Panel fasteners. Frequencysubject to applied loads

Air seal - Continuous bead ofgun grade sealant

BENCHMARKDri-Design Cassette

Kingspan Topdek InsulatedMembrane Roof Panel.Thickness to meet U value

BENCHMARKDri-Design Cassette

Aluminium parapet coping


Recommended