2
+ Red Red Yellow Count Up BLK BLK Display Board 00 to 99 Counter Display - Connection Diagram Non-Resettable CAT# CTR-92 Control Board 9 VAC AC1 (red) AC2 (red) 0V (yellow) ~ ~ AC Connection OR Power Supply DC Connection + or Ground (-) 1) Connect power supply to control board Cut small plug from end of wire and remove an inch or more of black jacket. White center lead is covered with wire mesh shield. Twist shield mesh together to form your ground lead (- lead) which connects to the yellow lead on the counter. Strip the end of the white lead and connect to one of the red leads. 2) Connect momentary, normally open push button to the black leads Each time this is pushed, the counter advances one digit.
Transcript
Page 1: 00 to 99 Counter Display - Connection Diagram Non-Resettable00 to 99 Counter Display - Connection Diagram Non-Resettable CAT# CTR-92 Control Board 9 VAC AC1 (red) AC2 (red) 0V (yellow)

+ Red

Red

Yellow

Count Up

BLK

BLK

Display Board

00 to 99 Counter Display - Connection Diagram Non-ResettableCAT# CTR-92

Control Board

9 VAC

AC1 (red)

AC2 (red)

0V (yellow)

~

~

AC ConnectionOR

Power SupplyDC Connection

+or

Ground (-)

1) Connect power supply to control boardCut small plug from end of wire and remove an inch or more of black jacket. White center lead is covered with wire mesh shield. Twist shield mesh together to form your ground lead (- lead) whichconnects to the yellow lead on the counter. Strip the end of the white lead and connect to one of the red leads.

2) Connect momentary, normally open push button to the black leadsEach time this is pushed, the counter advances one digit.

Page 2: 00 to 99 Counter Display - Connection Diagram Non-Resettable00 to 99 Counter Display - Connection Diagram Non-Resettable CAT# CTR-92 Control Board 9 VAC AC1 (red) AC2 (red) 0V (yellow)

MODIFICATION FOR RESET FUNCTIONCAT# CTR-92 – 2-DIGIT COUNTEROne of our customers figured out how to make our two-digit counter, CAT# CTR-92, resettable. Using that information, we present you with the following solution.

Required parts:1 each -- Momentary, normally open pushbutton

switch CAT# PB-160 or similar1 each -- 0.01Uf, 50V disc capacitor CAT# 103D501 each --10K 1/4W resistor CAT# 291-10K1-2 feet of insulated wire, 22AWG stranded or similar. Different colors are useful

1. See Figure 1 -- Cut the PC board copper traces in two places to isolate Pin 15 on the two CD4033 Counter ICs.You can carefully use a Dremel tool or blade of some sort. It is important to break the circuit to solder spot withoutharming the solder spot or the rest of the circuit. Note that the pin is in the lower quadrant of the IC on the left sideof the board and the upper quadrant on the right side. 2. See Figure 2 -- Solder a jumper wire between the two pins.3. See Figure 3 -- We attached all of the circuitry to the push-button switch. Obviously, if you have a better idea, go for it.Solder a 0.01uDF disc capacitor between the two terminals on the normally-open, momentary pushbutton switch. At the same time solder a wire lead to each terminal and another lead & a 10K resistor in-line to the other terminal.4. The lead with the resistor connects to the Negative (-) lead of the power supply. The other lead on that side connects to the jumper on the circuit board. The other lead connects to the positive lead of the power supply.

Vcc

Reset

0.01uF

10K

PushbuttonSwitch

To PC board &jumper

CD4033Pin 15

Jumperbetween pin 15, CD4033

CD4033Pin 15

Cut trace here Cut trace here

Figure 1

Enlargement of this area Enlargement of this area

10K 1/4WResistor

To negative-9 Vdc (ground)0.01 uf

disc cap.To +9 Vdc To jumper on

PC Board

Figure 3Reset Button

Figure 2Jumper wire and lead to pushbutton


Recommended