ACTIVATED SLUDGE
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
3/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
INDEX
1 Generalities
2 Carbon removal
3 Nitrogen removal
4 Phosphorous removal
5 Clarifier
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
4/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
Simple
Cheap
Efficient
A lot of references
existing
Why the activated sludge remains the
most popular biological process forwastewater treatment ?
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
5/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
Activated sludge
Transformation of colloids and solublecompounds in settleable biomass
Separation of solid and liquid phase
Functions
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
6/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
AS : Generalities
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
7/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
AS : BOD efficiency vs. Applied load
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
8/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
Relation between sludge age and Applied load
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
9/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
Sludge settleability
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
10/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
What is bulking?
Bad floc SVI 200-900 ml/g
Ideal floc = SVI < 150-200 ml/g
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
11/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
Tokophrya EpistyllisVorticelle
Rotifre Aelosoma
(annlide)
Nmatode
Some good microorganism
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
12/27
Toute reproduction interdite sans autorisation crite pralable de VeoliaWater Solutions & Technolgies Tous droits rservs pour tous pays
Some Filaments and foams
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
13/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
Some cause of filamentous bacteria
Low dissolved oxygen
Sulphures (septic effluent)Greases, oils
Long sludge Age
Low Nutriments (N, P..)
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
14/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
In the net
Short retention timeNo deposits
If possible aeration
In the WWTP
Contact zone (or selector), anaerobiczone
Not too long sludge ages
Alternating presence / absence O2
Preventives Solutions
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
15/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
ANTI-BULKING techniques
Anaerobic zone
+ Biological P elimination
Selector AS Clarification
Primary
settling
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
16/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
ANTI BULKING techniques
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
17/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
Activated sludge :Range values
> 90%
90%
1.3
0.65 to 0.9
0.32 to 0.6
0.08 to 0.25
Low
load
>95%
95%
90%
-
80%
-
50%
-
Removal efficiencies
C
N
0.6 to 0.80.91.01.3Sludge production
Kg SS/ Kg removed BOD5
> 1.30.80.550.45O2 consumption
Kg O2/ Kg removed BOD5
Volume load
Kg BOD5/m3/d
Mass load
Kg BOD5/kg SS/d
>2.0
>1.0
Very high load
0.04 to 0.080.25 to 0.750.75 to 1.0
0.2 to 0.320.8 to 1.01.0 to 2.0
High load Extended
aeration
Intermediate
load
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
18/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
ACTIVATED SLUDGE
AERATIO
N
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
19/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
ACTIVATED SLUDGE
generalities
Oxygen equipments
Type of aeration equipments :Surface aerators
Diffused aeration
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
20/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
Surface aeration
Turbines
Efficiency 0,8 1,2
kg O2/kWh
Brushes
Efficiency 1,2 1,8
kg O2/kWh
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
21/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
Air diffusion
Synthetique membranes +
Compressors
Efficiency 1,0 3,0 kg
O2/kWh
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
22/27
Carbon elimination
Average load
Activated Sludge
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
23/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
AS : Average load Example Angers,
France
Design load 1986 250 000 PE:
Flow: 52 000 m3/d 5500 m3/h
COD: 42 600 kg/d
BOD: 15 100 kg/d
TSS: 18 500kg/d
Max load 2003 260 000
PE:
Flow: 79 000 m3/d
COD: 45 400 kg/d
BOD: 15 900 kg/d
TSS: 19 050kg/d
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
24/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
AS : Average load Example Angers,
France
Influent
Excess sludge
AS : continous aeration
Sludge recirculation
Clarification
Treated water
Primary settling
Primary sludge
1 circular primary tank 38 m
2 Classical Multiflo 5x24 m1 AS basin 3250 m3
1 AS basin 5000 m3
Sludge age 3-5 days
F/M ratio 0,2 kgBOD/kg TSS/d
1 circular settling tank 40 m
1 circular settling tank 50 m
5 Clariflo with lamellas 5x17 m
Effluent guarantee
COD: 125 mg/l
BOD: 30 mg/lTSS: 35 mg/L
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
25/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
AS : Average load Example Angers,
FranceAngers Multiflo + Activated Average load activated sludge
0
100
200
300
400
500
600
700
800
900
1 000
00-janv-00 18-juil-00 03-fvr-01 22-aot-01 10-mars-
02
26-sept-02 14-avr-03 31-oct-03 18-mai-04 04-dc-04
Date
Infl
uent
COD
BOD
TSS
8/14/2019 003 as Generalities_Bo Mon_ Xu_ Ly_ Nuoc_ Thai_ Sinh_ Hoat
26/27
Toute reproduction interdite sans autorisation crite pralable de Veolia
Water Solutions & Technolgies Tous droits rservs pour tous pays
AS : Average load Example Angers,
FranceAngers Multiflo + Activated Average load activated sludge
0
20
40
60
80
100
120
140
160
180
200
00-janv-00 18-juil-00 03-fvr-01 22-aot-01 10-mars-
02
26-sept-02 14-avr-03 31-oct-03 18-mai-04 04-dc-04
Date
Effluent
COD
BODTSS
BLOWER FAILURE