5
WWW.SDCSECURITY.COM SECURITY DOOR CONTROLS Security Door Controls ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1 Communicating Bathroom Package Pre-spec’d so you don’t have to. One part number covers it all, whether you’re looking for a mortise, cylindrical, or electromagnetic locking system. Each Shared Bathroom Package is complete with everything needed to ensure privacy and coordinate emergency access to a common bathroom facility from adjoining rooms in hospitals, long term care facilities, schools and dormitories. (2) Electrified Locking Devices (Mortise, Cylindrical or ElectroMagnetic) (1) 1.5 Amp Power Supply with Universal Relay Module (631RFXUR1) (2) Emergency Access Push Button Switches (CB400-B) (1) System Activation Push Button Switch (CB400-A) (2) Build-in Latch or Door Position Status Sensors (DPS , L) (2) Power Transfer Hinges* *(not required for EMLocks) (PTH) PACKAGE COMPONENTS: MODELS CBP-ME-78 includes Eclipse style mortise locks (Z7850LQDE) CBP-MG-78 includes Galaxy style mortise locks Z7850LQDG) MORTISE LOCK OPTION: CB400-A Series CB400-B Series W A R R A N T Y YEAR 5 CBP-CE-72 includes Eclipse style cylindrical locks (Z7250EQ) CBP-CG-72 includes Galaxy style cylindrical locks (Z7250GQ) CYLINDRICAL LOCK OPTION: CBP-EM-81 includes EMLock locking devices 650lb (1581VD) CBP-EM-71 includes EMLock locking devices 1200lb (1571VD) CBP-EM-11 includes EMLock locking devices 1650lb (1511VD) ELECTRO MAGNETIC OPTION: Every Shared Bathroom Package also includes a Riser Diagram, Components List, Method of Operation and Wiring Diagram to help you determine the materials and installation costs to complete your project bid. 85 ŽŽƌ ϭ ŽŽƌ Ϯ ŽŽƌ ηϭ ŽŽƌ ηϮ
Transcript
  • WWW.SDCSECURITY.COM SECURITY DOOR CONTROLS

    Security Door ControlsACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1

    Communicating Bathroom PackagePre-specd so you dont have to. One part number covers it all, whether youre looking for a mortise, cylindrical, or electromagnetic locking system. Each Shared Bathroom Package is complete with everything needed to ensure privacy and coordinate emergency access to a common bathroom facility from adjoining rooms in hospitals, long term care facilities, schools and dormitories.

    (2) Electrified Locking Devices (Mortise, Cylindrical or ElectroMagnetic)

    (1) 1.5 Amp Power Supply with Universal Relay Module (631RFXUR1)

    (2) Emergency Access Push Button Switches (CB400-B)

    (1) System Activation Push Button Switch (CB400-A)

    (2) Build-in Latch or Door Position Status Sensors (DPS , L)

    (2) Power Transfer Hinges* *(not required for EMLocks) (PTH)

    PACKAGE COMPONENTS:

    MODELS

    CBP-ME-78 includes Eclipse style mortise locks (Z7850LQDE)

    CBP-MG-78 includes Galaxy style mortise locks Z7850LQDG)

    MORTISE LOCK OPTION:

    CB400-A Series

    CB400-B Series

    WARRANT

    Y

    YEAR5

    CBP-CE-72 includes Eclipse style cylindrical locks (Z7250EQ)

    CBP-CG-72 includes Galaxy style cylindrical locks (Z7250GQ)

    CYLINDRICAL LOCK OPTION:

    CBP-EM-81 includes EMLock locking devices 650lb (1581VD)

    CBP-EM-71 includes EMLock locking devices 1200lb (1571VD)

    CBP-EM-11 includes EMLock locking devices 1650lb (1511VD)

    ELECTRO MAGNETIC OPTION:

    Every Shared Bathroom Package also includes a Riser Diagram, Components List, Method of Operation and Wiring Diagram to help you determine the materials and installation costs to complete your project bid.

  • 2017 SECURITY DOOR CONTROLS WWW.SDCSECURITY.COM

    Security Door Controls

    LIT-CBP COMMUNICATING BATHROOM PACKAGE 08/17

    [t] 800.413.8783 805.494.0622 [f] 866.215.3138 801 Avenida Acaso, Camarillo, CA 93012 PO Box 3670, Camarillo, CA 93011

    APPLICATION

    Z7850 x DPS Electrified Mortise Lock with Door Status

    631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module

    402-B Emergency Release Button

    PTH Power Transfer Hinge

    1581 x DPS EMLock 650lb1571 x DPS EMLock 1200lb1511 x DPS EMLock 1650lb

    Z7250 Electrified Cylindrical Lock with Latch Status

    PTH Power Transfer Hinge

    402-A System Activation Button

    631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module

    402-B Emergency Release Button

    402-A System Activation Button

    631RFXUR-1 1.5 Amp, 12/24 VDC Class 2 Output Power Supply w/Comm. Bath Control Module

    401-B Emergency Release Button

    401-A System Activation Button

  • C NO C NO - NO C NC - NO C NC

    - +

    TRIG A TRIG B RELAY A RELAY B

    w

    DA

    w

    DB

    J1

    UR-1

    PWR

    PROJECT NAME:

    DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:

    SO NO.: REVTITLE:-801 Avenida Acaso

    Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861

    www.sdcsecurity.com

    --

    --

    2-Door Communicating Bath System Electrified Cylindrical Solution

    - [email protected] --06/17Page 1 of 3

    -

    2017 Security Door Controls Printed in U.S.A

    Door 1

    Door 2

    EMERGENCY

    RELEASE

    PUSHTO UNLOCK DOOR

    CB402-B

    (OUTSIDE DOOR 2)

    CB402-A

    ACTIVATION

    BUTTON

    SWITCH

    (INSIDE)

    C

    N/CN/O

    YEL

    WHT

    C

    N/CN/O

    YEL

    WHT

    BATHROOM LOCKBOTH DOORS MUST BE

    CLOSED TO LOCK

    LIGHT ON DOOR LOCKED

    PUSH TO LOCK

    EMERGENCY

    RELEASE

    PUSHTO UNLOCK DOOR

    CB402-B

    (OUTSIDE DOOR 1)

    C

    N/CN/O

    YEL

    WHT

    RED

    RED

    LAMP

    RED

    RED

    LAMP

    ROCKER SWITCH SETTINGS:

    SWITCH #1 IS ON

    ALL OTHER SWITCHES OFF

    WET/DRY SELECTION JUMPERS:

    Both A & B set to WET

    WET

    DRY

    RED

    RED

    LAMP

    Method of Operation:

    Both doors are normally closed and unlocked.

    System Activation:

    Upon entering the bathroom and closing both doors,

    momentarily pressing the Activation Button will lock both

    doors and turn ON the indicator lamps on the Activation

    and Emergency Release Buttons, indicating the system

    is active.

    System Deactivation:

    Operating the inside lever to retract the latch on either

    door will unlock both doors and turn off all indicator

    lamps. Using a key override from the outside to enter

    either door will also reset the system and unlock both

    doors.

    Emergency Override:

    Momentarily pressing either Emergency Release Button

    located outside each door will immediately unlock both

    doors and reset the system.

    CBP-C Series System Components:

    (1) 631RFXUR1 1A Power Supply w/

    Comm. Bath Controller

    (1) CB402-A Activation Button

    (2) CB402-B Emergency Release Button

    (2) Z7250EQ or Z7250GQ Electrified

    Cylindrical Lock, Eclipse or Galaxy Lever

    (2) PTH-4Q 4.5"x4.5" Power Transfer

    Hinge

    Battery

    Charger

    Indicator Fuse

    AC Power

    LED

    Primary

    Fuse 250V

    1.5AmpBattery

    Input

    System Status

    LED

    G W B

    TO 120VAC PRIMARY

    VOLTAGE CONNECTION

    (Remove factory installed jumper only

    when fire alarm interface is used)

    +

    -

    DC Voltage

    Output

    Terminals+ - C

    12V

    S

    H

    O

    R

    T

    O

    P

    E

    N24V

    VOLTAGE

    SELECT

    Note:

    SET TO 24VDC.

    Power must be turned

    off before changing

    voltage jumper631RF

    NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE

    PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS

    CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE

    WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL

    WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES

    FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.

    22/4C

    AC

    Mains

    (3) COND

    18/4C

    22/4C

    18/4C

    Z7250EQ/GQ

    Electrified Cylindrical Lock

    (Fail-Safe)

    Z7250EQ/GQ

    Electrified Cylindrical Lock

    (Fail-Safe)

    631RF

    Power

    Supply

    x UR-1

    PTH-4Q

    Power

    Transfer

    Hinge

    PTH-4Q

    Power

    Transfer

    Hinge

    CB402-A

    Activation

    Button

    CB402-B

    Emergency

    Release

    (Outside)

    CB402-B

    Emergency

    Release

    (Outside)

    Door #1 Door #2

    22/4C

  • C NO C NO - NO C NC - NO C NC

    - +

    TRIG A TRIG B RELAY A RELAY B

    w

    DA

    w

    DB

    J1

    UR-1

    PWR

    PROJECT NAME:

    DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:

    SO NO.: REVTITLE:-801 Avenida Acaso

    Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861

    www.sdcsecurity.com

    --

    --

    2-Door Communicating Bath System Electrified Mortise Solution

    - [email protected] --06/17Page 2 of 3

    -

    2017 Security Door Controls Printed in U.S.A

    Door 1

    Door 2

    EMERGENCY

    RELEASE

    PUSHTO UNLOCK DOOR

    CB402-B

    (OUTSIDE DOOR 2)

    CB402-A

    ACTIVATION

    BUTTON

    SWITCH

    (INSIDE)

    C

    N/CN/O

    YEL

    WHT

    C

    N/CN/O

    YEL

    WHT

    BATHROOM LOCKBOTH DOORS MUST BE

    CLOSED TO LOCK

    LIGHT ON DOOR LOCKED

    PUSH TO LOCK

    EMERGENCY

    RELEASE

    PUSHTO UNLOCK DOOR

    CB402-B

    (OUTSIDE DOOR 1)

    C

    N/CN/O

    YEL

    WHT

    RED

    RED

    LAMP

    RED

    RED

    LAMP

    ROCKER SWITCH SETTINGS:

    SWITCH #1 IS ON

    ALL OTHER SWITCHES OFF

    WET/DRY SELECTION JUMPERS:

    Both A & B set to WET

    WET

    DRY

    RED

    RED

    LAMP

    Method of Operation:

    Both doors are normally closed and unlocked.

    System Activation:

    Upon entering the bathroom and closing both doors,

    momentarily pressing the Activation Button will lock both

    doors and turn ON the indicator lamps on the Activation

    and Emergency Release Buttons, indicating the system

    is active.

    System Deactivation:

    Operating the inside lever & opening either door will

    unlock both doors and turn off all indicator lamps. Using

    a key override from the outside to enter either door will

    also reset the system and unlock both doors.

    Emergency Override:

    Momentarily pressing either Emergency Release Button

    located outside each door will immediately unlock both

    doors and reset the system.

    CBP-M Series System Components:

    (1) 631RFXUR1 1A Power Supply w/

    Comm. Bath Controller

    (1) CB402-A Activation Button

    (2) CB402-B Emergency Release Button

    (2) Z7850LQDE or Z7850LQDG

    Electrified Mortise Lock w/ DPS, Eclipse or

    Galaxy Lever

    (2) PTH-4Q 4.5"x4.5" Power Transfer

    Hinge

    Battery

    Charger

    Indicator Fuse

    AC Power

    LED

    Primary

    Fuse 250V

    1.5AmpBattery

    Input

    System Status

    LED

    G W B

    TO 120VAC PRIMARY

    VOLTAGE CONNECTION

    (Remove factory installed jumper only

    when fire alarm interface is used)

    +

    -

    DC Voltage

    Output

    Terminals+ - C

    12V

    S

    H

    O

    R

    T

    O

    P

    E

    N24V

    VOLTAGE

    SELECT


Recommended