+ All Categories
Home > Documents > 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Date post: 07-Nov-2020
Category:
Upload: menani.zineddine
View: 9 times
Download: 0 times
Share this document with a friend
29
Baseband on-site troubleshooting | 2017-03-05 | Page 0 (29) Baseband 5212 Site Operation, Alarm Handling
Transcript
Page 1: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 0 (29)

Baseband 5212 Site Operation, Alarm Handling

Page 2: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 1 (29)

› Install EMCLI

› Using EMCLI for Checking Site Operation

› Common Faults

› Fault Handling by Alex

Agenda

Page 3: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 2 (29)

Installation EMCLIQuá trinh tích hợp tại trạm đã thực hiện xong

Truy cập link sau https://169.254.2.2/em/index.html để download Cygwin and Element

Management Launcher. Hai chương trình này dùng để kiểm tra alarm, trạng thái cell…

Download và cài đặt như hướng dẫn bên dưới.

Page 4: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 3 (29)

Installation EMCLI Run file setup-x86.exe

Chọn Install from Local Directory, thư mục Root Directory giữ nguyên

Trỏ đến thư mục Cygwin_emcli_2.1.0_3

Page 5: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 4 (29)

Installation EMCLI Chọn các thư mục cài đặt như bên dưới

Sau khi cài đặt xong Cygwin, cài phần mềm EMCLI

Page 6: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 5 (29)

Installation EMCLI Sau khi cài đặt xong, giao diện EMCLI như hình bên dưới

Nhập địa chỉ IP của baseband 169.254.2.2, xong chọn Yes rồi click vào EMCLI

ở bên phải

Page 7: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 6 (29)

Using EMCLI for checking Site

Operation Sau khi click vào EMCLI giao diện EMCLI như hình dưới.

Nhập lệnh lt all để load toàn bộ MO của trạm

User: rbs

Pass: rbs

Page 8: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 7 (29)

› Install EMCLI

› Using EMCLI for Checking Site Operation

› Common Faults

› Fault Handling by Alex

Agenda

Page 9: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 8 (29)

Logical Components of an WCDMA

RBS

Cell Cell

Cell Cell

Radio Unit

Sector

Digital Unit

Support System

TMA TMA

X

X

X

X

X

X

Antenna

Unit Group

OSS-RC

Cell Cell

Remote

Radio Unit

Sector

CPRI Connection

X

X

X

Antenna

Unit Group

O&M

RNCIub

Page 10: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 9 (29)

Check Alarm at Site Sử dụng command alt để kiểm tra cảnh báo tại trạm

Mỗi cảnh báo sẽ bao gồm:

– Thời gian xuất hiện cảnh báo (ngày & giờ)

– Phân loại mức độ nghiêm trọng của cảnh báo (Critical – C; Major – M, Minor

– m, Warning – W)

– Tên cảnh báo tương ứng

– MO liên quan tương ứng bị ảnh hưởng

Page 11: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 10 (29)

Check Equipment at Site Sử dụng command st field để kiểm tra hardware như RU/RRU tại trạm

Như hình trên thì RRU tại S1/S2/S3 đều đang hoạt động.

TH nếu RRU/RU bị trạng thái “Disable” như bên dưới thì cần phải kiểm tra

lại cảnh báo tại trạm

Page 12: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 11 (29)

Check Equipment at Site Trong TH bị lỗi RRU “disable” nên sử dụng command st rilink để kiểm tra

lại kết nối quang giữa Baseband và RRU

Thông thường RRU sẽ không enable được do mất kết nối quang giữa

Baseband và RRU

Page 13: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 12 (29)

Check Antenna Part Một số lỗi thường gặp: High VSWR (RL Low)

Sử dụng command cabx để kiểm tra giá trị

VSWR tại trạm

Đảm bảo giá trị VSWR nằm trong ngưỡng cho

phép

RBS

RRU

ANT

ANT port

RBS ant portRBS

ANT

Main-RemoteFeeder

B: Ref. Pt.RX

power

A: Ref. Pt.TX/RX power

ANT feeder

ANT jumper

Optical fiber

Antenna part

Page 14: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 13 (29)

Sử dụng command st cell để kiểm tra nhanh trạng thái của cell

Cần đảm bảo sau khi xử lý xong thì cell phải được enable, trường hợp vẫn còn

phát sinh lỗi thì nên phối hợp với đội tích hợp tại RNC

Check Cell State

Page 15: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 14 (29)

Sử dụng command cvls để kiểm tra software đang sử dụng

Gói software đang sử dụng là bản “R16EK – 16B”

Đảm bảo sử dụng đúng gói upgrade software được cung cấp trong dự án

Check Software running at Node

Page 16: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 15 (29)

Sử dụng command lpr router để kiểm tra quá trình tích hợp (chạy

SmartLaptop hoặc Web-Integrate) có khai báo đủ OAM & Traffic cho trạm

hay chưa

MO AddressIPv4 sẽ chứa thông tin địa chỉ IP tại trạm

MO NextHop sẽ chứa thông tin địa chỉ IP Default Router 0

Check Transmission at Node

Page 17: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 16 (29)

Sử dụng command get để lấy thông tin IP đang sử dụng, cần đảm bảo giá trị

này chính xác với quy hoạch IP có trong ATND

Địa chỉ IP OAM của Node

Địa chỉ Default Router của OAM

Check Transmission at Node

Page 18: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 17 (29)

Sử dụng command sau để ping test từ Node về Default Router, cũng như OSS

Command synctax: mcc <MO_IpAddress> ping <IpAddress> --count 5

Ping test

Page 19: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 18 (29)

› Install EMCLI

› Using EMCLI for Checking Site Operation

› Common Faults

› Fault Handling by Alex

Agenda

Page 20: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 19 (29)

Common FaultsMột số lỗi thường gặp trong khi triển khai

Link Failure

Power Loss

VSWR Over Threshold

SFP Stability Problem

Service Unavailable

No Connection

HW Fault

RET Failure

RET Not Calibrated

Page 21: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 20 (29)

Link Failure AlarmSever Specific Problem MO (Cause/AdditionalInfo)

=========================================================================================

Min Link Failure RiLink=RI_A (Not in operation.

ManagedElement=1,Equipment=1,FieldReplaceableUnit=1,RiPort=A (transportType=NOT_SET))

Min Link Failure RiLink=RI_B (Not in operation.

ManagedElement=1,Equipment=1,FieldReplaceableUnit=1,RiPort=B (transportType=NOT_SET))

Mô tả: lỗi mất kết nối quang giữa Baseband và RRU, quan sát đèn chỉ

thị CPRI tại vị trí port A/B/C sẽ tắt

Checking: trong quá trình lắp đặt đã làm hỏng dây quang hoặc gắn

dây quang chưa khớp với module SFP

Action:

– Thử cắm lại dây quang tại vị trí SFP của Baseband & RRU

– Swap dây quang để kiểm tra lại, nếu vẫn còn xuất hiện lỗi thì

thay thế dây quang

Page 22: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 21 (29)

Power Loss AlarmSever Specific Problem MO (Cause/AdditionalInfo)

==============================================================================

Min Power Loss FieldReplaceableUnit=RRU-1 (Power Failure Alarm (PFA).)

Min Power Loss FieldReplaceableUnit=RRU-2 (Power Failure Alarm (PFA).)

Min Power Loss FieldReplaceableUnit=RRU-3 (Power Failure Alarm (PFA).)

Mô tả: RRU đang trong quá trinh hoạt động thì bị mất nguồn

Checking: đèn chỉ thị Operation của RRU đang tắt

Action:

– Kiểm tra lại nguồn của RRU

– Sau khi bật nguồn cho RRU cần kiểm tra lại đèn chỉ thị Operation của

RRU sáng

Page 23: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 22 (29)

VSWR Over Threshold Mô tả: giá trị VSWR đo được tại port RF A/B/C/D vượt quá ngưỡng

Checking: cell đang bị lock khi kiểm tra trạng thái hoạt động

Action:

– Kiểm tra kết nối của port RF RRU và dây cáp jumper

– Kết hợp với câu lệnh cabx để kiểm tra lại giá trị VSWR sau khi xử lý

– Swap jumper giữa các port để kiểm tra cáp jumper, TH cần thiết thì

thay thế jumper mới

Page 24: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 23 (29)

SFP Stability Problem Alarm:Sever Specific Problem MO (Cause/AdditionalInfo)

==============================================================================

Warn SFP Stability Problem FieldReplaceableUnit=1,SfpModule=A (SFP VCC-LOW

alarm.)

Mô tả: lỗi xuất hiện khi điều kiện hoạt động của SFP không thỏa mãn, có thể

là nhiệt độ, công suất Tx/Rx đo tại SFP …

Checking: SFP bị lỗi dẫn đến các điều kiện hoạt động của SFP không đảm

bảo

Action:

– Kiểm tra lại SFP đang sử dụng có tương thích với thiết bị phần cứng

hay không

– Thử rút ra rồi gắn lại SFP để kiểm tra kết nối giữa SFP và port CPRI,

nếu vẫn còn lỗi thì thay thế SFP mới

Page 25: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 24 (29)

HW Fault Alarm:=====================================================================

Sever Specific Problem MO (Cause/AdditionalInfo)

=====================================================================

Min HW Fault FieldReplaceableUnit=RRU-1 (Not functional carrier HW

resources [ DL/A ])

Mô tả: lỗi thiết bị hỏng cần thay thế, lỗi này sẽ đi kèm với tên của thiết bị

cần thay thế

Checking: nếu RRU/Baseband bị lỗi này thì đèn chỉ thị Fault (màu đỏ) sẽ

sáng

Action:

– Thay thế thiết bị hư hỏng sau đó kiểm tra lại cảnh báo

Page 26: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 25 (29)

› Install EMCLI

› Using EMCLI for Checking Site Operation

› Common Faults

› Fault Handling by Alex

Agenda

Page 27: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 26 (29)

Fault Handling by Alex

Page 28: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 27 (29)

Fault Handling bằng Alex

Tham khảo mục 1.Alarm Description để biết mô tả về lỗi

Tham khảo mục 3.Procedure để biết cách xử lý lỗi

Page 29: 03.b_Baseband Site Operation & Alarm Handle_V1.pdf

Baseband on-site troubleshooting | 2017-03-05 | Page 28 (29)


Recommended