FOR MORE INFO +33 (0) 557 977 780 PE Labory Baudan II - 105, rue Gay Lussac 33127 Saint Jean d’Illac - France Fax : +33 (0) 557 977 781 Email : [email protected] www.polyprocess.fr High performance polyester products The purpose of the Fire Resistant Systems developed by POLYPROCESS is to delay or slow the combustion of naturally inflammable resin glass laminates. The main objective is safety: evacuating and rescuing people, response by emergency services, preventing fire propagation, preventing intoxication by vapours and fumes. Respecting the company’s QSE policy, the Fire Resistant Systems do not use technologies based on halogens (chlorine and bromine), or antimony. HALOGENS ANTIMONY 0% Panneaux fabriqués par Rollecate - Photo Schiphol Hotel Property Company, Xander Richters.
Transcript

FOR MORE INFO +33 (0) 557 977 780

PE Labory Baudan II - 105, rue Gay Lussac 33127 Saint Jean d’Illac - FranceFax : +33 (0) 557 977 781 Email : [email protected]

www.polyprocess.fr

High performance polyester products

The purpose of the Fire Resistant Systems developed by POLYPROCESSis to delay or slow the combustion of naturally inflammable resin glasslaminates.

The main objective is safety: evacuating and rescuing people, response by emergency services, preventing fire propagation, preventing intoxication by vapours and fumes.

Respecting the company’s QSE policy,the Fire Resistant Systems do not usetechnologies based on halogens(chlorine and bromine), or antimony.

HALOGENSANTIMONY0%

Pann

eaux

fabr

iqué

s pa

r Rol

leca

te -

Phot

o Sc

hiph

ol H

otel

Pro

pert

y Co

mpa

ny, X

ande

r Ric

hter

s.

FOR MORE INFO +33 (0) 557 977 780

PE Labory Baudan II - 105, rue Gay Lussac 33127 Saint Jean d’Illac - FranceFax : +33 (0) 557 977 781 Email : [email protected]

www.polyprocess.frHigh performance polyester products

FR SYSTEM

The Intumescent Fire Resistant systems developed by POLYPROCESS have improved fire safety. Formulated from intumescent fillers, on contact with flames they create a protective carbon foam on the surface, hence limiting the propagation of the fire.

IFR SYSTEM

The Fire Resistant systems developed by POLYPROCESS have improved fire safety. They are formulated from aluminium hydroxides.

RATINGS

HALOGENSANTIMONY0%

HALOGENSANTIMONY0%

EUROCLASS EN 13-501 European fire resistance standard for construction materials

NF 16 101 French standard determining fumes

NF 92-501 French fire resistance standard for construction materials

M2/F1 GCIG FR21 and PO FR 531 RESINM1/F0 GCIG FR10 and PO FR 510 RESINM1/F1 GCIG IFR11 and PO IFR 511 RESINM2/F1 GCIG FR21 and PO FR 531 RESIN

B-s2-d0 POLYFIRE FR Series B + POLYFIRE FR 1000 RESINB-s2-d0 POLYFIRE IFR Series B + POLYFIRE IFR 1500 RESINE-s3-d0 GCIG WHITE XMA 90000 + STANDARD RESIND-s3-d0 GCIG WHITE XMA 90000 + POLYFIRE FRD 1000 RESIN D-s2-d0 GCIG WHITE XMA 90000 + POLYFIRE FR 1000 RESIN D-s3-d0 POLYFIRE FR Series B + STANDARD RESIN D-s3-d0 POLYFIRE IFR Series B + STANDARD RESIN

OMI International Marine Organization /SOLAS RATING for sea transport

Rating for floor POLYFIRE FR Series M + POLYFIRE FR 3000 RESINcovering

Rating for floor POLYFIRE IFR Series M + POLYFIRE IFR 3500 RESINcovering UL94 STANDARD US standard for devices and appliances

V0 Rating GCIG FR21 + PO FR 531

EN45545 STANDARD Railway applications, in accordance with R1, R7, R17 requirements

HL2 Rating POLYFIRE IFR Series R + POLYFIRE IFR 2800 RESIN Available in SPI version for injection and infusion applications