1

© 2009 Delmar, Cengage Learning

Foundations of Fire Fighting Tactics and Strategies

Chapter 5 Page101

Page 2: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

2

© 2009 Delmar, Cengage Learning

Objectives

• Describe the process of developing the fire fighting strategy and tactics involved in planning, locating, confining, extinguishing, and overhauling fires in buildings and other special fire situations

• Discuss the methods used for the determination of the proper fire operating mode: offensive, transitional, defensive, or non-attack mode

2

Page 3: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

3

© 2009 Delmar, Cengage Learning

Objectives

• Define the term size-up and explain the steps and factors involved in making a size-up

• Review the fire strategy and tactics used by firefighters and apply the fire behavior characteristics discussed in the text to the situations reviewed

• Describe difficult fire situations encountered by firefighters and the strategies and tactics they should use to resolve these situations 3

Page 4: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

4

© 2009 Delmar, Cengage Learning

Introduction

• Learn about:– Structure fires and fire behavior patterns most likely

to be encountered– How to apply fire behavior tactics

• Overall mission for fire incidents has three major components: finding the location of the fire, confining the fire, and extinguishing the fire

• Size-up: method used to identify problem(s) presented by the incident 4

Page 5: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

5

© 2009 Delmar, Cengage Learning

Development of Strategy and Tactics

• Overall mission for firefighters responding to fire:– Locate the fire– Confine the fire– Extinguish the fire

• Decision-making model: overall strategy on emergency incidents

5

Page 6: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

6

Page 7: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

7

Page 8: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

8

© 2009 Delmar, Cengage Learning

Development of Strategy and Tactics (cont’d.)

Figure 5-2 The five steps in the decision-making model

Page 9: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

9

© 2009 Delmar, Cengage Learning

Attack Modes

• Offensive mode: make a direct attack on fire for purposes of control and extinguishment

• Transitional mode: shifting from offensive to defensive mode or from defensive to offensive mode

• Defensive mode: conducted on exterior of building to protect adjacent buildings from fire spreading

9

Page 10: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

10

© 2009 Delmar, Cengage Learning

Attack Modes (cont’d.)

• Non-attack mode (passive approach): under certain circumstances, a fire attack may be too dangerous and incident command will choose to let the fire burn out without an attack– Cannot be made without careful consideration and by

making every effort to include the owner in the decision making process

10

Page 11: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Mill Fires

11

Page 12: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

12

© 2009 Delmar, Cengage Learning

Size-Up at the Incident Scene

• RECEO-VS– Rescue– Exposures– Confinement– Extinguishment– Overhaul– Ventilation– Salvage

12

Page 13: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

13

© 2009 Delmar, Cengage Learning

Construction

• Includes building components, materials, and extent of their fire-resistive abilities

• Five NFPA classifications – Type I, II, III, IV, and V

13

Page 14: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

14

© 2009 Delmar, Cengage Learning

Type I or Fire-resistive Construction

• Columns, beams, floors, walls, and roof made of materials classified as non-combustible

Figure 5-4 Type I orfire-resistive construction

Page 15: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

15

© 2009 Delmar, Cengage Learning

Type II or Non-combustible Construction

• Non-combustible and either protected or unprotected

Figure 5-5(a) Type II or noncombustible construction

Page 16: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

16

© 2009 Delmar, Cengage Learning

Type III or Exterior Protected/Ordinary Construction

• Exterior walls made of masonry materials

• Interior walls and materials permitted to be partially or wholly combustible

Figure 5-6 Type III or ordinary construction

Page 17: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

17

© 2009 Delmar, Cengage Learning

Type IV or Heavy Timber/Mill Construction

• Exterior walls are usually made of masonry and therefore are non-combustible

Figure 5-7 Type IV or heavy timber/mill construction

Page 18: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

18

© 2009 Delmar, Cengage Learning

Type V or Wood Frame Construction

• All major structural components can be made of combustible materials

Figure 5-8 In Type V construction, all major structural components can be made of combustible materials

Page 19: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

19

© 2009 Delmar, Cengage Learning

Occupancy or Use

• The building code that classifies buildings by their use

• Loss of lives in building fires is always a concern where large numbers of people gather

19

Page 20: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

20

© 2009 Delmar, Cengage Learning

Apparatus and Staffing

• Standard operating procedure (SOP): specific information and instructions on how a task or assignment is to be accomplished

• Need to know manpower resources– Number, type of pumping, and ladder capability

20

Page 21: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Need to Know Resourses

21

Page 22: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

22

© 2009 Delmar, Cengage Learning

Life Hazard

• Primary search– Aggressive primary search for victims during the first

few moments after arrival

• Personal alert safety system (PASS)– Small, motion sensitive unit attached to and worn with

the SCBA by firefighters when entering an Immediately Dangerous to Life and Health (IDLH) environment

22

Page 23: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

23

© 2009 Delmar, Cengage Learning

Terrain

• Structure can be built on land with different grade levels

• Careful pre-incident planning can help in reducing the time required to deal with terrain problems

23

Page 24: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

24

© 2009 Delmar, Cengage Learning

Water Supply

• Can water be delivered in sufficient gallons per minute to suppress the number of BTUs being given off by the fire?

• Learn location of water lines of other jurisdictions or districts

24

Page 25: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

25

© 2009 Delmar, Cengage Learning

Auxiliary Appliances

• Fire sprinklers have record of over one hundred years of being 90% to 98% effective in controlling fires

• Three types of water sprinkler application systems – Wet pipe– Dry pipe– Deluge

25

Page 26: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

26

© 2009 Delmar, Cengage Learning

Street Conditions

• Narrow streets, traffic congestion, double-parked cars, and construction work can severely impact fire operations

• Close coordination with public works and traffic departments can reduce such problems

26

Page 27: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Narrow Streets

27

Page 28: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

28

© 2009 Delmar, Cengage Learning

Weather

• Extreme weather conditions can affect operations

• Rehabilitation system:– Hydration– Nourishment– Rest and recovery– Medical evaluation

28

Page 29: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Rehab Unit

29

Page 30: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

30

© 2009 Delmar, Cengage Learning

Exposures

• Using water by running it down side of exposed building, coating it with water

• Water spray can protect against movement of heated air currents and direct flame impingement

• Use large water appliances to reduce or redirect air currents and to cool threatened building surfaces

30

Page 31: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

31

© 2009 Delmar, Cengage Learning

Area and Height

• Indicates maximum potential fire area• Height of building raises issues of whether the

fire department has necessary ladder lengths to reach upper building areas

• Height may provide exposure hazard to nearby buildings

• Impacts use of master streams

31

Page 32: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

32

© 2009 Delmar, Cengage Learning

Location and Extent of Fire

• The lower the fire, the more serious the threat of fire is to the building

• Fire below grade such as a basement fire, are hotter, and generally more complex

32

Page 33: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

33

© 2009 Delmar, Cengage Learning

Time

• May determine life-threatening situation• Time of day impacts time required for a fire

apparatus to arrive– Morning and evening traffic peaks can double the

response time

33

Page 34: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

34

© 2009 Delmar, Cengage Learning

Special Concerns

• Personnel accountability report (PAR): reports on location/condition of personnel

• Personnel accountability system (PAS): determines entry/exit of personnel

• Rapid intervention team or crew (RIT/RIC): assignment of group for rapid deployment of reports on personnel in trouble/missing

34

Page 35: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

35

© 2009 Delmar, Cengage Learning

Building Construction Methods and Occupancy Types

• Platform construction method: floors built separately from outer walls and ceiling and floor area serves as fire block to stop movement of hot fire gases between floors

• Balloon frame method of construction: obsolete construction method where wood studs run from foundation to roof and floors are nailed to studs

35

Page 36: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

36

© 2009 Delmar, Cengage Learning

Fire Behavior in Specific Occupancies

• Different procedures need followed for various types of buildings

• Important to understand essential differences of building methods and building types when evaluating how to approach a fire

36

Page 37: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

37

© 2009 Delmar, Cengage Learning

Single-Story Family Dwellings of the Past

• 1940s – 1950s– Plastered walls covering wood/wire mesh which was

painted/covered with heavy paper or cloth– Bare wood, rugs, linoleum, wool carpets– Bare wood to upholstered furniture with cotton, wool,

or leather– Rooms poorly insulated with single-paned windows– Fire load was low and the rooms were well ventilated

37

Page 38: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

38

© 2009 Delmar, Cengage Learning

Today’s Residential Properties

• Better insulation and increase in fire load• More plastics• Interior fire fighting hotter• Decreased time to flashover• Has become much more dangerous in these

occupancies

38

Page 39: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

39

© 2009 Delmar, Cengage Learning

Multiple-family Dwellings

• Vary from city to city

Figure 5-16 Open atticand truss construction

39

Page 40: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Strip Mall Fires

40

Page 41: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

41

© 2009 Delmar, Cengage Learning

Mercantile Fires

• Strip malls made as cheaply as possible• Barely meet code requirements• Fire originating in one store of a strip has good

chance of communicating to others – Can extend into cockloft area and once there, will

move horizontally with little or no resistance

• Roof ventilation is important

41

Page 42: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Hotel Fires

42

Page 43: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

43

© 2009 Delmar, Cengage Learning

Hotel Fires

• Not designed with fire safety in mind• Older hotels built with open stairways and rooms

off of corridors with transoms• HVAC units can circulate hot fire gases

throughout the building if unit is not protected with fire dampers

• Not equipped with an eyebrow– Designed to prevent or inhibit fire and smoke from

lapping into the upper floor(s) in a multistory building43

Page 44: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

44

© 2009 Delmar, Cengage Learning

Industrial Occupancies

• Vary considerably due to manufacturing processes

• Tenant factory/loft building– Potential for a fast-spreading fire is high

• Newer manufacturing buildings constructed using concrete tilt-up construction– Provide open void spaces where fire gases can

accumulate

44

Page 45: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

45

© 2009 Delmar, Cengage Learning

Churches

• Similar construction• Large hanging ceilings or cocklofts lead to

church’s destruction• If steeple present, collapse is likely• Life safety record for church fires is good

45

Page 46: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

46

© 2009 Delmar, Cengage Learning

Schools

• Fire drills usually constructed• Significant improvement in the use of fire-

resistant construction materials in new schools• Some schools use modular classrooms

46

Page 47: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Basement Fires

47

Page 48: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

48

© 2009 Delmar, Cengage Learning

Basement Fires

• Good location for storage of combustible items• Can become fully developed and present a very

hot, smoky fire situation where visibility is limited• Long hoses may be required• Possibility of gas ignition

48

Page 49: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

49

© 2009 Delmar, Cengage Learning

Attic Fires

• Burn upward• Respond quickly to proper vertical ventilation• Should be attacked as fast as possible• As little water as possible should be used

49

Page 50: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

Attic Fires

50

Page 51: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

51

© 2009 Delmar, Cengage Learning

Flat Roofs

• Attic space is approximately three feet deep and provides open space between underside of roof and top side of ceiling

• Always work with wind at your back or side from where the wind is blowing: windward side– Keeps smoke and hot gases downwind

51

Page 52: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

52

© 2009 Delmar, Cengage Learning

Peaked Roofs

• Encourage the use of aerial ladders• Roof ladder also used if aerial not possible• Vent hole cut as close to the ridge as possible

without damaging the underlying rafters– Should be made on leeward side

52

Page 53: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

53

© 2009 Delmar, Cengage Learning

Carport/Garage

• Carport: freestanding structure open on all sides– Carport itself is not serious fire problem because it is

constructed using a minimum amount of combustible materials

– Flammable liquid fires common

• Garage– One-story: line inside house to prevent extension of

the fire into this area– Two-story: direct attack on garage and line upstairs

53

Page 54: 1 © 2009 Delmar, Cengage Learning Foundations of Fire Fighting Tactics and Strategies Chapter 5 Page101.

54

© 2009 Delmar, Cengage Learning

Summary

• Understand basic principles of fire fighting and characteristics of fire behavior

• Three efforts:– Locate the fire– Confine the fire– Extinguish the fire

• Determine type of attack necessary