1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability Only 1 moving part MTBF of over 2 Years Simultaneous amplification and detection Closed, solid barrier amplification reaction system Isothermal Low maintenance Efficient workflow LIS capable
Transcript
Page 1: 1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability –Only 1 moving part –MTBF of over 2 Years Simultaneous.

1

BD ProbeTec™ ET System

• High Throughput – 552 test results per 8-hour shift

• Excellent reliability– Only 1 moving part– MTBF of over 2 Years

• Simultaneous amplification and detection

• Closed, solid barrier amplification reaction system

• Isothermal• Low maintenance• Efficient workflow• LIS capable

Page 2: 1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability –Only 1 moving part –MTBF of over 2 Years Simultaneous.

2

BD ProbeTec™ Reagents

• Dry lyophilized reagents

• Room temperature storage

• 96-well microtiter plate format

Page 3: 1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability –Only 1 moving part –MTBF of over 2 Years Simultaneous.

3

BD ProbeTec™ ET System

• The only “CLOSED, SOLID BARRIER”

amplification reaction system on the market– Solid (plastic seal) barrier to

amplicon contamination– Never opened or accessed after

the start of amplification

Page 4: 1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability –Only 1 moving part –MTBF of over 2 Years Simultaneous.

4

10 - 13 feet total linear footprint*

* 13 feet with the CA6000 Centrifuge.

Instrumentation and Footprint

BD ProbeTec™ ET System

Page 5: 1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability –Only 1 moving part –MTBF of over 2 Years Simultaneous.

5

Workflow Overview

Sample preparation.

Specimens are incubated for lysis for 30 minutes.

Specimens are cooled for 15 minutes.

150 µL of lysed specimen is added to the Priming plate to reconstitute reagents and then incubates for 20 minutes.

Priming plate is incubated with the Amplification plate for 10 minutes (hot start).

100 µL is transferred from the Priming plate to the Amplification plate.

Plate sealer is placed onto the Amplification plate.

Sealed plate is placed in the BD ProbeTec™ instrument. Results are available in 60 minutes.

Page 6: 1 BD ProbeTec™ ET System High Throughput – 552 test results per 8-hour shift Excellent reliability –Only 1 moving part –MTBF of over 2 Years Simultaneous.

6

BD ProbeTec™ ET Pipettor

• 8 samples at a time• Programmable –

touch of a button• Performs aspiration

& dispense steps• Re-chargeable• Uses aerosol

resistant tips with filter


Recommended