Dosimetric Control System Dosimetric Control System for the IBR-2 Reactorfor the IBR-2 Reactor
Joint Institute for Nuclear ResearchFrank Laboratory of Neutron Physics
A.S. KirilovM.L. KorobchenkoS.V. KulikovF.V. LevchanovskiyS.M. MurashkevichT.B. Petukhova
NEC’2011
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Control the radiation situation
Technological premises
Personnel work places
Atmospheric emissions
NEC’2011
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Monitoring of ionizing radiation
Alpha-aerosols
Beta-aerosols
Beta-active gases
Gamma-ray
Neutron
NEC’2011
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Dosimetric Control System
“System 8004-01”
132 detectors
12 shutters
Multichannel
block of counters
FT245 USB FIFO
TCP/
IP
NEC’2011
Remote computer
Control computer
USB-interface
The reactor dosimetric control room
Main control room of the reactor
CAM A C
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Data-transfer CircuitDetectors Control Circuit
Detector Signal Shapers
Hardware: Block of counters
NEC’2011
USB interface
D001
D132
F001
F132
ALTERA FT245R PC
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Software package
Multichannel Block of Counters
d_sdc
Database VARMANs_sdc
SDC
SDC_SERVER
SDC_CLIENT
TCP/IP
US
B
NEC’2011
Hardware
Control computer
Remote computer
Data Procession
User Graphical Interface
Block Driver
User Graphical Interface
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКСNEC’2011
Control computer: Main Window
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Data Processing
NEC’2011
The data processing module periodically stores logs to hard disk in individual files:
• current levels of radiation
• maximal levels of radiation during observation and the time of their appearance
• exceedance of the threshold values: - time of its appearance - threshold exceedance duration - corresponding dose during the threshold exceedance in any channel
• integral values of radiation levels
• mean values of radiation levels during the shift
• beam shutters status log
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Control computer: Main Window
NEC’2011
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Remote computer: graphical interface
NEC’2011
Мурашкевич С.М. ОИЯИ ЛНФ НЭОКС
Conclusion
A new dosimetric control hardware and software complex for the IBR-2 reactor was put into operation in the winter of 2010.
In the summer of 2011 the complex was successfully tested during the trial start-up of the modernized reactor.