+ All Categories
Home > Documents > 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale...

1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale...

Date post: 29-Jan-2016
Category:
Upload: jack-underwood
View: 215 times
Download: 0 times
Share this document with a friend
Popular Tags:
17
1 Industry leading Industry leading Temperature & Temperature & Humidity Humidity Control Control and Monitoring and Monitoring with Ethernet in-built with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back” to return
Transcript
Page 1: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

1

Industry leading Industry leading Temperature & Temperature &

Humidity Humidity Control Control

and Monitoring and Monitoring with Ethernet in-builtwith Ethernet in-built

Industry leading Industry leading Temperature & Temperature &

Humidity Humidity Control Control

and Monitoring and Monitoring with Ethernet in-builtwith Ethernet in-built

Phasefale JouleTemp

Click left mouse button to advance, “back” to return

Page 2: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

2

Click left mouse button to advance, “back” to return

ApplicationsApplications Cool Rooms in all situationsCool Rooms in all situations Medical and Pathology Medical and Pathology

applicationsapplications Production environmentsProduction environments HACCPHACCP Environmental control includingEnvironmental control including

HumidityHumidity

Page 3: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

3

Click left mouse button to advance, “back” to return

Features & BenefitsFeatures & Benefits

Reliable and robust control; hassle Reliable and robust control; hassle free keeps your customers happyfree keeps your customers happy

Powerful control, defrost and alarmPowerful control, defrost and alarmfunctionsfunctions

Inbuilt data loggingInbuilt data logging

Page 4: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

4

Click left mouse button to advance, “back” to return

Simple to useSimple to use

easy to install and commissioneasy to install and commission programming via keypad OR programming via keypad OR

your Computeryour Computer clear, precise instructionsclear, precise instructions local support and backuplocal support and backup Instructions available on lineInstructions available on line

from our websitefrom our website Backup program to text fileBackup program to text file

Page 5: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

5

Click left mouse button to advance, “back” to return

No CONFUSION!No CONFUSION! fully featured control meets fully featured control meets

requirements for cool room requirements for cool room and freezer applications, and freezer applications, plus many moreplus many more

a single model covers a wide a single model covers a wide spectrum of requirementsspectrum of requirements

in-built data logging of in-built data logging of temperature & humiditytemperature & humidity

Software all browser based, Software all browser based, no installationno installation

Page 6: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

6

Click left mouse button to advance, “back” to return

JouleTemp: Control FunctionJouleTemp: Control Function

On/OFF control function: Cool /Heat + On/OFF control function: Cool /Heat + Optional HumidityOptional Humidity

2 stages each control *2 stages each control * controls cool room solenoid controls cool room solenoid

or compressoror compressor accurate, precise with power saving accurate, precise with power saving

optionoption PID Option proportional,PID Option proportional,

derivative, integral)derivative, integral) Limit Start timerLimit Start timer

* limit total 4 control outputs * limit total 4 control outputs with option PCB with option PCB

Page 7: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

7

Click left mouse button to advance, “back” to return

DefrostDefrost up to 12 defrosts per dayup to 12 defrosts per day Set exact time for each Set exact time for each

defrostdefrost manual initiation/ manual initiation/

terminationtermination heater drain functionheater drain function fan start delay functionfan start delay function separate defrost separate defrost

termination sensor termination sensor optionoption

Page 8: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

8

Click left mouse button to advance, “back” to return

Alarm FunctionsAlarm Functions very sophisticated; best very sophisticated; best

available. available. high, low setting with time high, low setting with time

delaydelay Door Alarm (or monitor)Door Alarm (or monitor) Light, buzzer in-built and Light, buzzer in-built and

security output security output acknowledge, panic inputacknowledge, panic input Transmit alarm via Dialler, Transmit alarm via Dialler,

Email or SMS ( SMS needs Email or SMS ( SMS needs service)service)

Page 9: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

9

Click left mouse button to advance, “back” to return

Data logging, SoftwareData logging, Software Set interval 1-60 minutesSet interval 1-60 minutes Graphs for monthsGraphs for months view via web browser interfaceview via web browser interface

Hover over point Hover over point displays statusdisplays status

Set time and date to Set time and date to viewview

Page 10: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

10

Click left mouse button to advance, “back” to return

Software - Main PageSoftware - Main Page

Page 11: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

11

Click left mouse button to advance, “back” to return

Software: Software: *settings page*settings page

*password protected*password protected

Page 12: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

12

Click left mouse button to advance, “back” to return

Software: Software: advancedadvancedsettings settings page*page*

*password protected*password protected

Page 13: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

13

Click left mouse button to advance, “back” to return

Software: Software: DiagnosticDiagnostic& & maintenancemaintenance

settings settings page*page*

*password protected*password protected

Page 14: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

14

Click left mouse button to advance, “back” to return

Software: Software: Event Event LogsLogsand and Periodic Periodic data data ( forExcel)( forExcel)

Page 15: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

15

Click left mouse button to advance, “back” to return

PCB for freezer PCB for freezer (Fan/Heater outputs)(Fan/Heater outputs)

JouleTemp accessories….JouleTemp accessories….

Alarm Light & BuzzerAlarm Light & Buzzer

AD2 Voice DialerAD2 Voice Dialer

other optionsother options

Humidity SensorHumidity Sensor Additional temp sensors Additional temp sensors

Page 16: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

16

Click left mouse button to advance, “back” to return

Warranty, Backup & SupportWarranty, Backup & Support

unlimited phone supportunlimited phone support 12 months warranty12 months warranty technical staff available to technical staff available to

provide telephone supportprovide telephone support On site service ( extra On site service ( extra

cost)cost)possiblepossible

Full installation quotesFull installation quotes

Page 17: 1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”

18

Click left mouse button to advance, “back” to return

AvailabilityAvailability

Ex stock at all timesEx stock at all times Small quantities overnightSmall quantities overnight Larger quantities next dayLarger quantities next day

Available through Available through refrigeration refrigeration

wholesalerswholesalers


Recommended