Date post: | 27-Dec-2015 |
Category: |
Documents |
Upload: | eunice-gaines |
View: | 220 times |
Download: | 1 times |
2
Two wire loop testers
Two wire loop testing
Objective of the instrument range:
• Two wire Non-tripping loop impedance measurement
• Improvement on existing loop test performance
• Extended operational voltage range
• New high resolution option
3
Two wire loop testers
LTW300 series loop testers
LTW315 replaces the LT310 No-trip 2 wire testing
2 wire fast test
CATIV 300V applications
0.01ohms resolution
100V to 280V loop testing
Auto test start
PFC Calculation
Backlit display
4
Two wire loop testers
LTW300 series loop testers
LTW325 replaces the LT320
Additional features over LTW315
50V centre tap testing
440V Phase to Phase testing
MaxZ – Maximum loop value
R1+R2 measurement
5
Two wire loop testers
LTW300 series loop testers
LTW335 replaces the LT330
Additional features over the LTW325
300 test result storage
• Job, db, ct, Ph etc
Result recall to screen
Downloading via USB
6
Two wire loop testers
LTW300 series loop testers
LTW425 new high resolution range
High resolution loop tester
No trip testing to 0.01ohms
0.001 resolution on high current test
Extended PFC calculation (40KA)
7
Two wire loop testers
LTW Benefits
All instruments: Direct replacements for the LT300 series
2 wire measurements on all loop tests
No tripping of RCDs
Automatic test extension on noise detection
50V to 440V loop measurement on all test modes
AUTO start on contact loop test
High resolution loop test (LTW425)
• Greater confidence in loop result
• Increased PSCC and PFC calculation range
CATII, III and IV, 300V applications
8
Two wire loop testers
Selling against the competition
Key sales point• Two wire NO-TRIP loop test
– Simple connection
– Radial circuits as easy as rings
– Safer testing – no loose leads
• CATIV applications– Used outside the premise
• 50V to 440V operation– Centre tap 110V applications (even RCD protected)
• Advanced noise detection system– Test extension and noise warning
9
Two wire loop testers
Selling against the competition
Additional sales points• High resolution 0.001ohm resolution• Extended PFC range to 40KA• R1+R2 and MaxZ measurements• Voltage and frequency measurement• Automatic voltage display• Large clear backlit display
• IP54 weatherproof case• Calibration certificate included • 3 year warranty
LTW425 display
10
Two wire loop testers
Product availability
Engineering product field trials continuing Pre-production run August 2006 Field trial units September 2006 FPS End September 2006 Product launch Beginning October 2006
LT to LTW product transfer
LT and LTW to run concurrently for 6 months
Sales teams to focus on transferring distributors and enquiries to new LTW
11
Two wire loop testers
Sales tools
Product launch document
Datasheets
Pricing/discount structure
Broad competitor comparison spreadsheet
Colour LTW single fold A4 brochure
A5 leaflet
Counter mats
Head -to- head comparisons
Simple old new conversion chart
Loop testing & CATIV applications guides
Presentation