Pneuma Series FeaturesPneuma 1
MODE
Dual Limb Dual LimbSingle Limb Single Limb*Single Limb*Ex-Valve
*Single Limb*Ex-Valve
PSIMVVACV
PACV
VSIMVAUTO (Emergency quick start)Spont+
PRVCO2StreamACPAP+ABIPAP+
Pneuma 2
OptionalNasal Cannula for O2Stream
Remark : *single limb * - Single limb circuit with external exhalation valve
SpO2
EtCO2
Peripherals
High Pressure Oxygen Mixer
Exhalation Drive Line InputLow Flow Oxygen Supply Inlet
Proximal Pressure Line Input
Trend Trend (72hrs)
[Technology] It is decreased Inspiratory Phase Work of Breathing through Inspiratory Trigger function and Pressure Support function. It makes possible to inhalation with small effort of patient (WOB_inspiration). It is decreased Expiratory Phase Work of Breathing through Ex_Sesnse. In this time, interrupt the flow rapidly and supply brk_time (Expiration Break Time). It makes possible to exhalation with small effort of patient (WOB_expiration) and minimize of breaths with difficulty.
* (brk_time: Expiration Break Time): Application to most convenience respiration pattern.
MTV 1000
O2 streamRecently the clinical aim of ventilator is minimized of lung injury and recovered of spontaneous respiration. It should be deal with carefully that interrupt ventilation and assistance of breathing in clinically. After weaning by ventilation, it may happen to use the ventilator (or assistance of breathing) again frequent. That is necessary a method for proper and effective assistance of breathing. The High Flow Therapy is suitable device for the method and it is contrived by principal that makes sufficient ventilation in the nasal cavity and upper airway. In this aspect, it isdifferent from Nasal CPAP. This function is using with Nasal Cannula was contrived specially and use with humidifier.
ACPAP+(Adaptive CPAP Plus Pressure Support)
[ACPAP+ Function] It is developed with high technology which applying to the highest class ICU ventilator and applying for a patent. It is innovated reaserch object comfortable breathing in CPAP. MEKICS created unique ACPAP+ technology completed the clinical effect and comfortable breathing simultaneous.
[Principal] Based on the CPAP, it is contrived to minimize of breaths with difficulty in CPAP as induction of airway open, pressure support that is decreased patients effort in inspiration, and active break (rapid pressure interruption) that makes easy of expiration.
Encorder for setting parameter 7 Color TFT Touch Screen
LAN, USB RS-232 Upgrade Port
Optional : SpO2, EtCO2
Proximal Pressure Line InputExhalation Drive Line Outlet
Home Care.
Transport.
Hospital.
Pneuma1
Pneuma1
Pneuma2
Dual Limb Circuit >PACV, PSIMV, VACV, VSIMV, Spont(Spont+PS) , PRVC,Apnea Back-up Ventilation, AUTO(Emergency Quick Start)
Single Limb Circuit >PACV, PSIMV, PRVC, Apnea Back-up Ventilation.ACPAP+, ABiPAP+Optional : SpO2, EtCO2
Dual Limb Circuit >PACV, PSIMV, VACV, VSIMV, Spont(Spont+PS), PRVC, AUTO(Emergency Quick Start), Apnea Back-up Ventilation.
Single Limb Circuit >PACV, PSIMV, PRVC, Spont(Spont+PS), Apnea Back-upVentilation, ACPAP+, ABiPAP+,O2 Stream with high flow oxygen supply.with High Pressure Oxygen MixerOptional : SpO2, EtCO2, Nasal Cannula for O2Stream
Multi Purpose Ventilator forHospital, Long Term Care and Transport
Trigger
Pressure
Flow-Machine
Flow-PatientEx.time
=Easy Expiration
PSV
Quick Pause