SMMS-i Data book
-110
10 Controls
1. Outline of application Control
S
ide
rem
ote
Mas
ter r
emot
e
Sch
edul
e
timer
TC
B-E
XS
21TL
E
Cen
tral r
emot
e co
ntro
ller
TCB
-SC
642T
LE2
R
emot
e O
N/O
FF
TC
B IF
CB
-4E
2
E
xter
nal m
aste
r ON
/OFF
boa
rd
TCB
-PC
MO
2E
Pow
er p
eak-
out c
ontro
l bo
ard
TCB
-PC
DM
2E
Err
or o
utpu
t con
trol b
oard
TC
B-P
CIN
2E
Bat
ch d
rive,
err
or o
utpu
t
Mas
ter O
N/O
FF s
igna
l
Err
or/o
pera
tion
outp
ut
Mas
ter O
N/O
FF s
igna
l P
ower
pea
k-ou
t con
trol s
igna
l
“1:1
mod
el” c
onne
ctio
n
TCC
-Lin
k In
terfa
ce
TCB
-PC
NT3
0TLE
2
Sup
er D
igita
l Inv
erte
r
Dig
ital I
nver
ter
SM
MS
S
MM
S-i
Ala
rm S
tatu
s ou
tput
ON
/OFF
C
omm
and
Min
i-SM
MS
BM
S-L
SV
4E
BM
S-IF
LSV
4UL(
U.S
.)
TCS
-Net
Rel
ay In
terfa
ce
Mod
bus
(M
aste
r)
BM
S-L
SV
6E
BA
Cne
t Ser
ver
TCB
-IFM
B64
0TLE
BA
Cne
t
LON
WO
RK
S
Gen
eral
Pur
pose
I/F
TCB
-IFC
G1T
LE
Touc
h-sc
reen
Con
trolle
r B
MS
-TP
0641
AC
E
BM
S-T
P51
21A
CE
B
MS
-TP
0641
PW
E
BM
S-T
P51
21P
WE
Com
plia
nt M
anag
er
BMS-
CM
1280
FTLE
C
ompl
iant
Man
ager
B
MS-
CM
1280
TLE
Wire
d re
mot
e co
ntro
ller
with
Wee
kly
timer
R
BC
-AM
S41
E
Wire
d r
emot
e co
ntro
ller
RB
C-A
MT3
2(31
)E
Sim
ple
rem
ote
cont
rolle
r R
BC
-AS
21E
2
Wire
less
rem
ote
cont
rolle
r
Rem
ote
Sen
sor
TCB
-TC
21LE
2
BM
S-W
B01
GTE
Mas
ter S
erve
r
Web
serv
er
BM
S-W
B25
61P
WE
BM
S-W
B25
61P
WE
Gat
eway
BM
S-W
B25
61P
WE
Gat
eway
Sen
sors
/sw
itch/
key/
actu
ator
.Lon
Wor
ks
Ana
log
I/F(D
Cvo
ltage
)
TCB
-IFLN
642T
LE/T
CB
-IFLN
642U
L
TCB
-IFC
B64
0TLE
Op
Ope
n Sy
stem
en
Sys
tem
Dai
seik
ai
GSM
REMO
TE C
ONTR
OL I/F
TCB
-IFG
SM
1E
GS
M M
odem
Air-c
ondi
tioni
ng M
anag
emen
t
Sys
tem
TCC
-LIN
K
Intra
net
Ene
rgy
mon
itorin
g R
elay
I/F
BM
S-IF
WH
5E
BM
S-IF
WH
5UL(
U.S
.)
Dig
ital I
/O
Rel
ay I/
F B
MS
-IFD
D03
E
BM
S-IF
DD
O3U
L(U
.S.)
Pow
er M
eter
I/O
Dev
ice
*Mon
itorin
g
*Rem
ote
cont
rol
*S
ched
ule
oper
atio
n
*Err
or c
ode
indi
catio
n
*Ala
rm li
st in
dica
tion
*M
onth
ly re
port
*E
nerg
y m
onito
ring
data
etc
.
1.Lo
nWor
ks: R
egis
tere
d tr
adem
ark
by E
chel
on c
orpo
ratio
n.2.
BA
Cne
t: A
NSI
/ASH
RA
E 1
35-1
995,
A da
ta C
omm
unic
atio
n Pr
otoc
ol fo
r B
uild
ing
Aut
omat
ion
and
Con
trol
Net
wor
k.
3.M
odbu
s: R
egis
tere
d tr
adem
ark
by S
chne
ider
E.
Not
es:C
o-ex
iste
nce
and
inte
rope
rabi
lity
of e
ach
prod
uct
shal
l be
re
ferr
ed
to
anot
her
docu
men
ts.
RS48
5
RS48
5 RS
485
RS48
5
RS48
5
RS48
5
RS48
5
RS48
5
RS48
5 TCC-
LIN
K
TCC-
LIN
K
TCC-
LIN
K
TCC-
LIN
K
TCC-
LIN
K
ON
-OFF
con
trol
ler
TCB-
CC16
3TLE
2
Err
or o
utpu
t con
trol b
oard
C
ompr
esso
r ope
ratio
n /s
yste
m o
pera
tion
ratio
(SM
MS
-i on
ly)
TCB
-PC
IN4E
Com
pres
sor o
pera
tion
/sys
tem
oper
atio
n ra
tio(S
MM
S-i
only
)
Ext
erna
l sw
TCB
-KB
OS1
E
for
SD
I4 o
nly
Cab
le fo
r co
nnec
tor
CN32
(TCB
-KBC
N32
VEE)
CN
60(T
CB-K
BCN
60O
PE)
CN61
(TCB
-KBC
N61
HAE
) CN
70(T
CB-K
BCN
70O
AE)
CN73
(TCB
-KBC
N73
DEE
) CN
80(T
CB-K
BCN
80EX
E)
Cab
le fo
r co
nnec
tor
CN32
(TCB
-KBC
N32
VEE)
CN
60(T
CB-K
BCN
60O
PE)
CN61
(TCB
-KBC
N61
HAE
) CN
70(T
CB-K
BCN
70O
AE)
CN73
(TCB
-KBC
N73
DEE
) CN
80(T
CB-K
BCN
80EX
E)
Ene
rgy
mon
itorin
g
Rel
ay
I/F
Dig
ital I
/O R
elay
I/F
Pow
er M
eter
I/O
Dev
ice
Ene
rgy
mon
itorin
g R
elay
I/F
D
igita
l I/O
Rel
ayI/F
Ene
rgy
mon
itorin
g R
elay
I/F
Dig
italI
/OR
elay
I/F
TCC-
LIN
K
TP
DC
lin
e
Air-
cond
ition
ing
Man
agem
ent S
yste
m o
n si
te
10Controls
-210
2. Applications for indoor remote controller
Basic function System diagram Model
2-1
Individual controlAir conditioner is individually operated at a distance.
• Wired remote controllerRBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Simple wired remote controllerRBC-AS21E2
• Wireless remote controller kitRBC-AX31U(W)-ERBC-AX31U(WS)-ERBC-AX22CE2TCB-AX21E2
2-2
GROUP controlOne remote controller can control a group of up to a max. 8 indoor units. Operating on the same setting.
• Wired remote controllerRBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Simple wired remote controllerRBC-AS21E2
• Wireless remote controller kitRBC-AX31U(W)-ERBC-AX31U(WS)-ERBC-AX22CE2TCB-AX21E2
2-3
Two remote controlAir conditioner is controlled by two remote controllers in two locations.
• Wired remote controllerRBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Simple wired remote controllerRBC-AS21E2
• Wireless remote controller kitRBC-AX31U(W)-ERBC-AX31U(WS)-ERBC-AX22CE2TCB-AX21E2
2-4
Control by schedule timer
Schedule timer mode and Weekly timer mode
• Wired remote controllerRBC-AMT32ERBC-AMT31E
• Central remote controllerTCB-SC642TLE2
• Schedule timerTCB-EXS21TLE
(((
Main remote controller
Receiver unit
Wireless remote controller
Indoor unit
Remote controller
Wireless remote
controller
Indoor unit
Max.8 indoor units
Indoor unit
Indoor unit
Indoor unit
Indoor unit
Remote controller
(((
( ( (
( ( (
Wireless system
Wired system
Indoor unit
Indoor unit
Remote controller
Remote controller
Wireless remote
controller 1
Wireless remote
controller 2
Master Side
Master Side
Indoor unit
Wired & Wireless combination control(Either one of the two controllers can be set as side control.)
Remote controller
Wireless remote
controller
When two wireless remote controllers are operated at the same time, the communication are not done by interference of both infrared rays.
Indoor unit
Central remote
controller
Schedule timer
Weekly timer modeSchedule timer mode
Schedule timer
Wired remote
controller
Indoor unit
TCC-LINK
SW setting at schedule timer is necessary.
10Controls
-310
3. Application control for central remote controller
Basic function System diagram Model
3-1Central management
controllers for 64/128 units Controller for 64 units(TCB-SC642TLE2)
• Individual control up to 64 indoor units• Individual control for max. 64 indoor units divided in to 4 zones
(Up to 16 indoor units for each zone)• Up to 16 outdoor header units are connectable.• Setting for one of 1 to 4 zones is available.
Controller for 128 units(BMS-CM1280TLE)• Individual control of up to (64 indoor units) 2 TCC-LINK buses• Individual control of up to (64 indoor units divided 1 to 64
zone) 2 TCC-LINK buses (Up to 64 indoor units for each zone)• Up to 16 outdoor header units are connectable per 1 TCC-LINK
bus• Setting for (one of 1 to 64 zones) 2ch is available.• Setting for (one of 1 to 64 groups) 2ch is available.• Return back setting
Common• 4 types central control settings to restrict individual operation by
remote controller are selectable.• Usable with other central control devices (Up to 10 central
control devices in one control circuit)• Two control mode selectively Contral controller mode/Remote
controller mode• Master/Sub setting possible
• Central remote controllerTCB-SC642TLE2BMS-CM1280TLE
Indoor remote controller• Wired remote controller
RBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Simple wired remote controllerRBC-AS21E2
• Wireless remote controller kit
Outdoor unit
Indoor unitLine-3
U3, U4
U5, U6
U1, U2
Single phase 220V
Powersupply
Central remote controller
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
Indoor remote controller
Indoor remote controller
Indoor remote controller
Line-2
Line-1
U3, U4
U3, U4
Zone4
Zone3
Zone2
Zone1
U5, U6
U1, U2
Header unit
Header unit
U1, U2
Header unit
Function of central remote controller
10Controls
-410
3-2
Central remote controller+
Schedule timerWeekly operation schedule can be set by connecting a schedule timer to the central remote controller
• Central remote controllerTCB-SC642TLERBC-CM1280TLE
+• Schedule timer
TBC-EXS21TLE
Indoor remote controller• Wired remote controller
RBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Simple wired remote controllerRBC-AS21E2
• Wireless remote controller kit
3-3
Either one of the two controllers can be set as
side control without indoor remote controller.
• Central remote controllerTCB-SC642TLE2
Indoor remote controller• Wired remote controller
RBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Wireless remote controller kit
Basic function System diagram Model
Outdoor unitU3, U4
U1, U2
Indoor remote controller
Indoor unit
Schedule timerCentral
remote controller
Power supply
Single phase 220V
Even when grouping operation is performed by connecting multiple indoor units to 1 line, the indoor remote controller is required.
Available
Available
U3, U4 Outdoor unitU1, U2
Indoor unitPower supply
Central remote controller
Single phase220V
Example of grouping operation
U3, U4Outdoor unitU1, U2
(Group)
Indoor remote controller is required
Central remote controller
Power supply
U3, U4Outdoor unitU1, U2
(Group)Power supply
Central remote controller
Single phase220V
Single phase220V
10Controls
-510
3-4 Central management control with ‘‘1 : 1 model’’
* TOSHIBA Digital Inverter System and Super Digital Inverter System
• Central remote controllerTCB-SC642TLE2BMS-CM1280TLE
• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).
Indoor remote controller• Wired remote controller
RBC-AMT32ERBC-AMT31E
• Wired remote controller with weekly timer RBC-AMS41E
• Simple wired remote controllerRBC-AS21E2
• Wireless remote controller kit
Basic function System diagram Model
Super MMS * 1
Power supply
Central remote controller
U3, U4
U1, U2
Header unit
Indoor unit
Indoor remote controller
“1 : 1 model” connection interface
10Controls
-610
4. Application control for network
Basic function System diagram Model
4-1-1 LONWORKS
*1TOSHIBA Digital Inverter System and Super Digital Inverter System
The LONWORKS interface should be connected between a building management computer and a Super MMS air conditioning system.
• LN InterfaceTCB-IFLN640TLE
• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).
4-1-2 BACnet
*1TOSHIBA Digital Inverter System and Super Digital Inverter System
The local server should be connected to the BACnet network, and the Super MMS air conditioning system through the interface.
• Intelligent serverBMS-LSV6E
• BACnet server softwareBMS-STBN08E
• TCS-Net Relay InterfaceBMS-IFLSV3E
• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).
4-1-3 Modbus
*1TOSHIBA Digital Inverter System and Super Digital Inverter System
• Modbus InterfaceTCB-IFMB640TLE
• ‘‘1 : 1 model’’ connection interfaceTCB-PCNT30TLE2High-wall type for SDI/DI is not necessary this. 4-way and compact 4-way cassette type for SDI/DI need the metal fitting kit (TCB-PX30MUE).
TCB-
Super MMS
LN Interface
Remote controller
LON centerLON WORKS
TCB-IFLN060
TCB-
* 1
“1:1 model”connection interface
• • •
TCB-
Super MMS
Intelligent server
TCS-NetRelay Interface
Remote controller
BACnet center
* 1
“1:1 model”connection interface
■ BACnet server software
TCB-
Super MMS
Modbus Interface
Remote controller
Modbus
* 1
“1:1 model”connection interface
10Controls
-710
Touch screen controller system
System diagram
4-2-1
Dev
ices
Model Name Model Name SpecificationTouch Screen controller BMS-TP0641ACE Max. 64 indoor units, without electrical bill calculation
BMS-TP5121ACE Max. 512 indoor units, without electrical bill calculationBMS-TP0641PWE Max. 64 indoor units, with electrical bill calculationBMS-TP5121PWE Max. 512 indoor units, with electrical bill calculation
TCS-Net Relay Interface BMS-IFLSV3E I/F in between Touch Screen controller & Control wiringEnergy Monitoring Relay Interface BMS-IFWH4E2 I/F for Power MeterDigital I/O Relay Interface BMS-IFDD02E2 I/F for I/O signal
Func
tion
(1) Monitoring air-conditioners Operation status can be viewed according to a unit.[Unit] All building, All tenants, Each tenant, Each area, Each air-conditioning system[Monitoring contents] Operation and alarm status, Setting status for each air-conditioning system
(2) Operating of air-conditioners Header/individual control can be performed according to a unit.[Operating contents] ON/OFF, Operation setting (operation mode, air volume, louver position,
setting temp., restricted setting from remote location)(3) Schedule operation Air-conditioners are operated according to the set-up schedule/operation pattern.
Schedule operataion can be performed according to a unit.[Operation pattern] Weekly pattern, special day pattern (4 pattern), Non-operation days pattern
(4) Alarm list display The present alarm contents are list-displayed.[Display contents] Alarm contents, Unit number, Generated time
(5) Alarm record display The alarm history records are displayed.[Display contents] Alarm contents, Unit number, Generated time
(6) Monthly report data extraction Monthly report data is written to ‘‘Compact Flash’’. Monthly reports can be created according to a unit using the monthly report software.[Monthly report contents] The number of ON/OFF, Operating time, Results of energy monitoring
Monthly report creation software
1:1model
Touch Screen Controller
Ethernet
RS-485 Relay I/F
Power Meter Energy monitoring Relay I/F
Digital I/O Relay I/F
Pulse signal
Digital I/O signal Fire alarmDoor key Error
TCC-link bus
TCC-link bus Fire alarm Door key etc
Digital I/O signal
Max12
Max8
Max8
Max8
Max In 8 /Out 4
Max In3 /Out3
Relay I/F
Connection I/F
Max 64/512 Indoors/groups
Power meter: Pulse width:50-1000ms Pulse generator constants (kWh/pulse) 0.1-99.9
10Controls
-810
Compliant Manager
System diagram
4-2-2
• Compliant ManagerBMS-CM1280TLE
• Compliant Manager with WEBBMS-CM1280FTLE
TCC-LINK LINE 1
Compliant Manager
TCC-LINK LINE 2
Local Supply (BMS-CM1280FTLE only)
HUB
Monitoring
Zone setting (64 zone x ~ 2)Individual units operation (ON/OFF, Operation mode, Setting temperature, Air volume, Filter sign)Operation restrictionAlarm display
Operation
Individual operationMax. 128 indoor unitsReturn Back operationWeekly Schedule Operation* (ON/OFF)External control inputStatus outputFire alarm inputAlarm display * accessory necessary
Web Application (WEB model only)
Network connectionSchedule operation (ON/OFF, Setting temperature, operation mode and Remote control Permit/Prohibit)Alarm historyEnergy monitoring external connection* * accessory necessary
10Controls
-910
WEB Based Controller
System diagram
4-2-3
WEB Based Controller• Gateway Server
BMS-WB2561PWE• TCS-Net Relay I/F
BMS-IFLSV3E
• Energy Monitoring Relay I/FBMS-IFWH4E2
• Digital I/O Relay I/FBMS-IFDD02E2
4-2-4
WEB Based Controller• Master server
BMS-WB01GTE• Gateway Server
BMS-WB2561PWE• TCS-Net Relay I/F
BMS-IFLSV3E
• Energy Monitoring Relay I/FBMS-IFWH4E2
• Digital I/O Relay I/FBMS-IFDD02E2
System diagram for connecting 256FCUs or less
BMS-WB2561PWE(Web Server) TCS-Net Relay I/F
TCC-LINK
TCC-LINK
SMMS
SMMS SMMS
MiNi-SMMS
BMS-IFLSV3E
BMS-IFLSV3E
TCS-Net Relay I/F
I/F for Power Meter(BMS-IFWH4E2)
I/F for I/O signal(BMS-IFDD02E2E)
Ethernet
RS-485
Network, Intranet, connection through LAN port
HUB
Local Supply
System diagram for connecting 257FCUs or more
Local Supply
BMS-WB01GTE(Master Server)
TCS-Net Relay I/F
TCC-LINK
TCC-LINK
SMMS
SMMS
SMMS
SMMS
SMMS
MiNi-SMMS
BMS-WB2561PWE(Gateway)
HUB
Ethernet
RS-485
SMMS
MiNi-SMMS
TCS-NetRelay I/F
TCS-Net Relay I/F
TCS-NetRelay I/F
TCC-LINK
TCC-LINK
I/F for Power Meter (BMS-IFWH4E2)
I/F for I/O signal(BMS-IFDD02E2E)
BMS-WB2561PWE(Gateway)
Network, Intranet, connection through LAN port Enable to connector up to 2,048 FCUs
RS-485
10Controls
-1010
Application control of optional devices connectable to indoor units
[1] Remote location ON/OFF control box
[2] ‘‘1 : 1 model’’ connection interface
Model Name Appearance Features
TCB
-IFC
B-4
E2
Start and stop of the air conditioner is possible by a external signal and indication of operation/alarm externally.
Application Function
• MonitoringON/OFF status (for indoor unit)Alarm status (system & indoor unit stop)
• ON/OFF commandAir conditioner can be turned ON/OFF by external signals.The external ON/OFF signals will initiate the signals shown below.
Model Name Appearance Features
TCB
-PC
NT3
0TLE
2
Install optional P.C. board in Electrical parts box of indoor unit.
Link adapter for ‘‘1 : 1 model’’ into super modular multi network
1 : 1 model: Super digital inverter Digital inverter
Connection of cables
Application
Wiring diagram of indoor P.C. board
Display
Operation
Interface
RemoteController ON/OFF
COM
Non-voltageON/OFF continious signal
ON-OFFcontroldevices
Central Remote Controller
1:1 model connection
interfaceIndoor units
Super MMS control wiring
Digital Inverter Super Digital Inverter
Outdoor unit
Metal fitting kit (TCB-PX30MUE) is necessary for 4-way and Compact 4-way cassette type.
adoptor
10Controls
-1110
Application controls by optional P.C. board of outdoor unit
Model name Application Feature
TCB
-PC
DM
4E
* Install these optional P.C.Board in the inverter assembly of the header outdoor unit.
[1] Power peak-cut ControlThe upper limit capacity of the outdoor unit is restricted based on the power peak cut request signal from outside.
TCB
-PC
MO
4E
[2] Snowfall fan controlOutdoor fan is operated by a snowfall signal from outside.
[3] External master ON/OFF controlThe outdoor unit starts or stops the system.
[4] Night operation (Sound reduction) controlSound level can be reduced by restricting the compressor and fan speeds.
[5] Operation mode selection controlThis control can restrict the selectable operation mode.
TCB
-PC
IN4E [6] Error/Operation output control
Error/operation are displayed and output.[7] Compressor operation output control
Three compressor’s operation/stop output[8] System operation output control