+ All Categories
Home > Documents > 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid...

1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid...

Date post: 01-Apr-2019
Category:
Upload: doquynh
View: 235 times
Download: 0 times
Share this document with a friend
18
- 1 -
Transcript
Page 1: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 1 -

Page 2: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

Pipeline or pipeline system

All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe, valves and other appurtenances connected to line pipe, pumping units, fabricated assemblies associated with pumping units, metering and delivery stations and fabricated assemblies therein, and breakout tanks.

- 2 -

Page 3: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 3 -

§195.1 Which pipelines are covered by this part? (c) Breakout tanks. Breakout tanks subject to this Part must comply with requirements that apply specifically to breakout tanks and, to the extent applicable, with requirements that apply to pipeline systems and pipeline facilities. If a conflict exists between a requirement that applies specifically to breakout tanks and a requirement that applies to pipeline systems or pipeline facilities, the requirement that applies specifically to breakout tanks prevails.

Page 4: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

§ 195.2 Definitions. Breakout tank means a tank used to (a) relieve surges in a hazardous liquid pipeline system or (b) receive and store hazardous liquid transported by a pipeline for reinjection and continued transportation by pipeline.

- 4 -

Page 5: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 5 -

Page 6: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,
Page 7: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 7 -

Flow Valve

Pump Meter

Breakout Tank

M

Main Line

Fenced

M

Jurisdiction

PHMSA

Tank Mixing system

Surge Tank (Breakout)

Relief

To vacuum truck

1

Page 8: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 8 -

Flow Valve

Pump Meter

Storage Tank

M

Main Line

Fenced

Storage Tank

Loading Area

Jurisdiction

PHMSA Not Jurisdictional

M

If meter is used in conjunction with Leak detection system; jurisdiction ends at Valve #3; if not, it reverts upstream to Valve #1 and #2.

3

2

1

Pig

Rece

iver

2

Page 9: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 9 -

Flow Valve

Pump Meter M

Main Line

Fenced

Storage Tank

Processing

Plant

If meter is used in conjunction with Leak detection system; jurisdiction ends at Valve #2; if not, it reverts up-stream to Valve #1.

M M

Jurisdiction

PHMSA Not

Jurisdictional

1

2 Outlet of Facility: PHMSA jurisdic-tion extends to the pressure influ-encing device which effects the main pipeline pressure.

3

Page 10: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 10 -

Flow Valve

Pump Meter M

Main Line

Fenced

Breakout Tank

Unloading Rack

M M

Breakout Tank

M

Loading Rack M M

M

Jurisdiction

PHMSA Not

Jurisdictional

4

Page 11: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 11 -

Flow Valve

Pump Meter M

Main Line

Fenced

Breakout Tank

M M

Breakout Tank

Loading Rack

Jurisdiction

PHMSA Not

Jurisdictional

5

Page 12: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 12 -

Flow Valve

Pump Meter M

Main Line

Jurisdiction

PHMSA Not

Jurisdictional

If meter is used in conjunction with Leak detection system; jurisdiction ends at Valve #2; if not, it reverts up-stream to Valve #1.

1

Fence

Storage Tank

M (Un)Loading Rack

Storage Tank

Storage Tank

Storage Tank

Storage Tank

Storage Tank

M

M 2

6

Page 13: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 13 -

Flow Valve

Pump Meter M

Main Line

Fenced

Breakout Tank

Unloading Rack

M M

Breakout Tank

M

Loading Rack M M

M

Jurisdiction

PHMSA Not

Jurisdictional

7

Page 14: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 14 -

Flow Valve

Pump Meter M

Main Line

Fenced

Breakout Tank

M M

Breakout Tank

Loading Rack

Jurisdiction

PHMSA Not

Jurisdictional

8

Page 15: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 15 -

Flow Valve

Pump Meter M

Main Line

Fenced

Breakout Tank

Refinery

M M

Storage Tank

M Loading Rack

Jurisdiction

PHMSA Not

Jurisdictional

9

Page 16: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 16 -

10

Page 17: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 17 -

Flow Valve

Pump Meter M

Main Line

If meter is used in conjunction with Leak de-tection system; jurisdiction ends at Valve #2; if not, it reverts upstream to Valve #1.

Fractionation Plant M M Loading Rack

Jurisdiction

PHMSA Not

Jurisdictional

Storage well

Storage well

Storage well

M

2

1

11

Page 18: 1 · Pipeline or pipeline system All parts of a pipeline facility through which a hazardous liquid or carbon dioxide moves in transportation, including, but not limited to, line pipe,

- 18 -

Flow Valve

Pump Meter

Storage Tank

M

Main Line

Fenced

Storage Tank

Un-Loading Area

Jurisdiction

PHMSA Unregulated

M

Pig

Laun

cher

Tank

Tank

Tank

Tank

This line is not regulated when the pipeline is low stress and

serves truck or rail, and is less than one mile long (measured

outside facility grounds).

12


Recommended