Compare the total cost ( Capital and running) for the following types of water heating: Solar type Electric type Gas type
Assuming the following data: Daily hot water usage = 150 liters, 6 hours/day Hot water temperature = 65 Co
Cold water temperature = 20 Co
The capital cost of solar heater = L.E. 4000, Bank interest rate = 10%
2
Water Heating Energy System Design
Annual maintenance for solar system= L.E. 75 and 20 years life time.
Assuming 30 days/year without solar thermal, and using electric system
The capital cost of electric heater = L.E. 1500 Annual maintenance for electric system= L.E. 50 The Electricity cost (flat rate) = 0.25 to 0.50 L.E. /kWh The capital cost of gas heater = L.E. 2000 The cost of gas bottle, 14 m3 = L.E. 20 to 30 L.E., and
consumed in two weeks Annual maintenance for gas system= L.E. 60
3
Water Heating Energy System Design
Outline
Hybrid Energy Systems (HES) Application in
Remote Area.
HES Application in Rural Areas (WWTP)
4
Hybrid Energy Systems (HES) Application in
Remote Area The problem:-
Optimum Sizing of Hybrid Energy System for Electrification of Remote Area in Egypt.
Solution:
Optimum topology selection ( Generator, PV, Wind, Hybrid, etc..),
Percentage share of each source,
Best operation strategies
Optimum components sizing,
Target :
for minimum overall system cost.
5
Hybrid Energy System (HES) A hybrid energy system can be defined as: “a combination of
different, but complementary energy supply systems at the same place.
It is commonly installed in remote areas isolated from the utility grid.
6
Advantages of Hybrid Energy System
Reductions in size of diesel engine and battery storage system,
which can save the fuel and reduce pollution.
Improves the load factors and help saving on maintenance and
replacement costs.
The cost of electricity can be reduced by integrating diesel
systems with renewable power generation.
7
Advantages of Hybrid Energy
System (Cont.) Renewable hybrid energy systems can reduce the cost of
high-availability renewable energy systems. This results from the system’s ability to take advantage of the complementary diurnal (night/day) and seasonal characteristics of available renewable resources at a given site.
On the other hand, high initial capital of the hybrid is a barrier
to adopt the system thus the needs for long lasting, reliable and cost-effective system.
8
Hybrid Energy System/ Applications (Remote Area)
Villages
Residential Buildings
Hospitals
Schools
Farmhouses
Hotels
Irrigation systems
Desalination Systems
10
Hybrid Energy System Optimization
General formulation of HES optimization problem:
The problem is to develop a multi-objective model to design a HES
with battery storage and diesel generators taking into consideration
future system expansion.
The design objectives are cost and CO2 gas emission minimization.
The problem constraints are:
(1) reliability constraint which dictates that a certain percentage of
the peak demand must be secured as a reserve,
(2) energy balance constraint.
11
HES Optimization Modeling Tools
HOMER: Hybrid Optimization Model for Electric Renewable by NREL(National Renewable Energy Laboratory’s) of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy by Midwest Research Institute RETSCREEN: developed by Natural Resources Canada's CEDRL with the contribution of 85 experts from industry, government and academia. HYBRID2: developed by NREL and the University of Massachusetts
12
Comparison between Modeling Tools 13
HES MODELLING WITH HOMER
Main features of HOMER:- HOMER’s fundamental capability is simulating the long-term
operation of a micropower system. Its higher-level capabilities, optimization and sensitivity
analysis, rely on this simulation capability. The simulation process determines how a particular system
configuration, a combination of system components of specific sizes, and an operating strategy that defines how those components work together, would behave in a given setting over a long period of time.
14
Schematic diagrams of some micro-power system types that HOMER models
15
HOMER Economics Analysis
HOMER uses the total net present cost (NPC) to represent the life-cycle cost of a system.
The total Net Present Cost of a system is the present
value of all the costs that it incurs over its lifetime, minus the present value of all the revenue that it earns over its lifetime. Costs include capital costs, replacement costs, O&M costs, fuel costs, emissions penalties, and the costs of buying power from the grid. Revenues include salvage value and grid sales revenue.
16
The NPC is calculated according to the following equation:
Where: TAC is the total annualized cost (which is the sum of the annualized costs of each system component).
Where: N is the number of years and ‘i’ is the annual real interest rate (%).
● The capital recovery factor (CRF) is given by:
17
System Under Study
Site Selection
Demand load and resources
Initial search space for system
components
Economic consideration,
System constraints and control
Net present cost
calculations
Optimization technology,
system components and sizing
18
Site selection Remote Village in East of Owienat area 22.35 °N and 28.42 °E It is 340 km from the nearest Egyptian electricity grid line at
Aswan City
19
20
Electrical Load Demand
kW
Hours 0
200
400
600
800
1000
1200
1400
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Load
21
Load demand 22
Renewable Energy Sources
Solar energy measured by kWh/m2/day
Source: Egypt atlas 23
Wind energy measured by m/s
Source: Egypt atlas 24
Source: NASA
25
Energy Resources
26
27
search space
28
Economics consideration
29
System Control
30
Constraints
31
System Components
32
Simulation Results
Case I : Generator only
Case II: Generator and PV
Case III: Generator, PV and Wind turbine
33
Case I : Generator only
34
35
The 11 possible results:-
36
37
Discussion for Case I:-
In case I we can have 11 possible solutions.
The optimum solution is to use two generators with 50%
load sharing.
The total NPC is $27,167,26.
38
Case II: Generator and PV
39
40
41
42
43
Discussion for case II :-
In this case, we have 2 possible solutions.
The optimum solution is to use the PV with 83% and the
Diesel Generator with 17%.
The NPC is $ 16,260,053.
44
Case III: Generator, PV and Wind turbine
45
46
47
48
Discussion for case III :-
For this case, there are 6 possible solutions.
The optimum solution is to use PV with 79 %, DG with 14%
and WT with 7%.
The NPC $ 14,518,144.
49
Results Discussion These results are based on the available data, subject to the
increase or decrease of the prices.
Diesel generator fuel Transportation cost was considered in the
fuel price (USD/Littre).
Wind turbine with low cut-in speed was chosen to match the
wind speed range in the selected site.
50
Conclusion
In this thesis, the world’s energy problem was discussed, mentioning its main drivers (world’s population, economic growth and energy prices).
Hybrid energy system was presented explaining its applications, different configurations, advantages and disadvantages.
HOMER software was chosen as the simulation tools for its great advantages over other programs.
51
Conclusion (cont.)
A case study ( remote village at East of Oienate ) was chosen and simulation carried out based on the available load data and renewable resources data.
The HOMER simulations results indicate that the use of hybrid energy source with the aid of available renewable resources (solar and wind) resulting in reduction of the NPC of the overall system from 27,167,26 (in case of diesel generators powered system) to 17,406,764 USD (in case of hybrid PV, wind, and diesel system)