T project package solution
BBU structure
15 4 8
16 3 7 14 2 6
13 1 5
Flexible installation mode - Mounted on the wall independently - 19 inch standard cabinet - Installed in the Hub cabinet - Installed in the outdoor cabinet
BBU installation
wall-mounted installation of BBU
On transmission rack or macro base station
Pole-mounted Installation Mode
Wall-mounted Installation Mode
LPU
DCPD & LPU
RRU
BBU
4.1. 8700_BC rack Install
Code Materials Qty Size mm
52904000001 8 hole busbar 1 07910200
0086 420*320*2
20
129554181000 ZXSDR BS8800 U240 1 52740204883 DS-91238-003| alarm cable 1 52740203332 NETS-91228-001| ethnet cable 10M 1 122600061652 .3|RJ45(0.3m) 1
4.1.8700- BBU Install
Code Materials Qty Size mm
52904000001 8 hole busbar 1 129553781004 ZXSDR B8200 GU360 1
066876024500
740*330*260
52740204883 DS-91238-003| internal alarm cable 1 52740203332 NETS-91228-001| ethnet cable 10M 1 122600061652 .3|RJ45(0.3m) 1 52740309842 PWR-96515-002| 2M BBU power cable 1 624104161001 | for cable laying 1 129554261080 1.35|DS-95542-001|| 1 129122861007 DS-91228-005| outsitde alarm cable 1
4.1.3RRU Install900M/1800M R8860E
Code Materials Qty Size mm 52740310663 PWR-95539-009|0.800 3
066876019300
560*435*515
56472000031 electical PVP tape 15 56472000030 water proof 9 624409054301 R8860 lable 1 129552480007 ZXWR R8840 EA(t>=-25 ) 3 51603000018 DC power module| PIMDC 3
4.1. 3RRU Install1800M/MBR R8882
Code Materials Qty Size mm
52740306628 PWR-95539-005 0.800 3
066876019300
560*435*515
56472000031 electical PVP tape 15 56472000030 water proof 9 624409054301 R8860 lable 1or2 129552480007 ZXWR R8840 EA(t>=-25 ) 3 51603000018 DC power module| PIMDC 3
RRU amout + RRU pole
RRU jumper
RRU firber cable
RRU outdoor power cable 2*4mm2
clamp for RRU power cable outdoor Y&G cable--16mm2
outdoor DC dule core cable--16mm2
metal pipe for firber and power cable
outdoor cable tray
daisy chain firber cable, 3M daisy chain RF cable, 3M
E1 cable, 10M DDF | 19 1/2 feeder cable 1/2"feeder clamp 1/2"feeder grounding clip 7/16 DM connector for 1/2 feeder cable
Code Material Rate Remark 624114018901 Basic part 1:01 1 RRU 624114019201 Common part
Code Material Rate Remark 624114018901 Basic part 1:02 2 RRU 624114019201 Common part
Code Material Rate Remark 624114018901 Basic part
1:03:01 3 RRU 624114019201 Common part 624114019001 extention part
16 pcs of 70M firber cable
30 pcs of 5M jumper cable
Site1 Site2 Site3
BBU BBU BBU
RACK RACK RACK
RRU1 RRU1 RRU1
RRU2 RRU2 RRU2
RRU3 RRU3 RRU3
Site Site1~10 Site11~20
BBU BBU
RACK RACK
RRU1 RRU1
RRU2 RRU2
RRU3 RRU3
Firber
Type BBU
UBPG SiteXX
RACK BBU
RRU1 RACK
1 RRU1
RRU2 1
2 RRU3
RRU3 3
3
Module
Firber
Deferent package solution
Q&A AC cabling if any should follow the following color codes:
Single Phase: Line: Brown Neutral: Blue Earth: Yellow / Green Three Phase: Line: Red/Yellow/Blue Neutral: Black Earth: Yellow / Green
DC Cabling shall follow following colors code: - Positive-Red - Negative-Blue - Earth-Green
T project package solutionBBU structure BBU installation wall-mounted installation of BBUOn transmission rack or macro base stationPole-mounted Installation ModeWall-mounted Installation ModeDCPD & LPU 9 10 11 12 13 14 15 16 17 18 19 20 21 22Q&A