ZXG10-BSS Base Station Subsystem Operation Manual (Performance Measurement Counter) Version 2.95 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected]
Transcript
Page 1: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSSBase Station Subsystem Operation Manual(Performance Measurement Counter)

Version 2.95

ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected]

Page 2: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

LEGAL INFORMATION Copyright © 2005 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. The contents of this document and all policies of ZTE CORPORATION, including without limitation policies related to support or training are subject to change without notice.

Revision History

Date Revision No. Serial No. Description

30/07/2006 R1.0 Sjzl20060779 English – For Customers

Page 3: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZTE CORPORATION Values Your Comments & Suggestions! Your opinion is of great value and will help us improve the quality of our product documentation and offer better services to our customers.

Please fax to: (86) 755-26772236; or mail to Publications R&D Department, ZTE CORPORATION, ZTE Plaza, A Wing, Keji Road South, Hi-Tech Industrial Park, Shenzhen, P. R. China 518057.

Thank you for your cooperation!

Document Name

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Management Counters)

Product Version V2.95 Document

Revision Number R1.0

Equipment Installation Date

Presentation: (Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization, Appearance)

Good Fair Average Poor Bad N/A

Accessibility: (Contents, Index, Headings, Numbering, Glossary)

Good Fair Average Poor Bad N/A

Your evaluation of this documentation

Intelligibility: (Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)

Good Fair Average Poor Bad N/A

Your suggestions for improvement of this documentation

Please check the suggestions which you feel can improve this documentation: Improve the overview/introduction Make it more concise/brief Improve the Contents Add more step-by-step procedures/tutorials Improve the organization Add more troubleshooting information Include more figures Make it less technical Add more examples Add more/better quick reference aids Add more detail Improve the index Other suggestions

___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ # Please feel free to write any comments on an attached sheet.

If you wish to be contacted regarding your comments, please complete the following:

Name Company

Postcode Address

Telephone E-mail

Page 4: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

This page is intentionally blank.

Page 5: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Contents

About this Operation Guide .......................................................... xi Purpose of this Operation Guide...............................................................xi Typographical Conventions.....................................................................xiii Mouse Operation Conventions................................................................xiv Safety Signs..............................................................................................xv How to Get in Touch................................................................................xvi

Customer Support ................................................................................................xvi Documentation Support ........................................................................................xvi

Chapter 1........................................................................................ 1

Key Performance Indicators.......................................................... 1 Network Performance Measurement ........................................................1

KPI Counters..........................................................................................................1 KPI Counters Explanation ........................................................................................5

Chapter 2......................................................................................39

BTS Measurement........................................................................39 Power Control Measurement .................................................................. 39

Power Control Counters.........................................................................................40 Power Control Counters Explanation.......................................................................41

TRX Service Measurement...................................................................... 49 TRX Service Counters ...........................................................................................50 TRX Service Counters Explanation..........................................................................52

Paging Messages Measurement ............................................................. 71 Paging Messages Measurement Counters................................................................71

TRX Basic Measurement ......................................................................... 71 TRX Basic Measurement Counters..........................................................................72

TRX Power &Temperature Measurement............................................... 72 TRX Power & Temperature Measurement Counters..................................................72 TRX Power & Temperature Measurement Counters Explanation................................72

Page 6: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 3......................................................................................75

Wireless Channels........................................................................75 Channels Measurement........................................................................... 75

Channels Counters................................................................................................75 Channels Counters Explanation..............................................................................77

Chapter 4......................................................................................87

Random Access ............................................................................87 Random Access Measurement................................................................ 87

Random Access Counters ......................................................................................87 Random Access Counters Explanation ....................................................................88

Chapter 5......................................................................................97

SDCCH Measurement ...................................................................97 SDCCH Counters...................................................................................... 97

SDCCH Counters Explanation.................................................................................98

Chapter 6....................................................................................107

TCH/F Measurement..................................................................107 TCH/F Counters..................................................................................... 107

TCHF Counters Explanation ................................................................................. 112

Chapter 7....................................................................................137

Service Access Point Identifier 3...............................................137 SAPI 3 Introduction .............................................................................. 137 SAPI 3 Counters .................................................................................... 138

SAPI 3 Counters Explanation ............................................................................... 139

Chapter 8....................................................................................147

Radio Management Module Measurement................................147 RMM Assignment Measurement ........................................................... 147

RMM Assignment Counters.................................................................................. 147 RMM Assignment Counters Explanation ................................................................ 148

RMM Queue Measurement.................................................................... 153 RMM Queue Counters ......................................................................................... 154

Chapter 9....................................................................................155

RMM Call Drop Measurement.....................................................155

Page 7: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

7

RMM Call Drop Counters ....................................................................... 155 Call Drop Counters Explanation............................................................................ 157

Chapter 10..................................................................................175

Handover Cause Measurement..................................................175 Handover Cause Counters..................................................................... 175

Handover Cause Counters ................................................................................... 175 Handover Cause Counters Explanation ................................................................. 177

Chapter 11..................................................................................193

General Handover Measurement...............................................193 Handover Counters ............................................................................... 193

Handover Counters Explanation ........................................................................... 198

Chapter 12..................................................................................241

Synchronization Mode Handover Measurement .......................241 Synchronization Mode Counters........................................................... 241

Synchronization Mode Counters Explanation ......................................................... 242

Chapter 13..................................................................................245

Paging Message Measurement..................................................245 Paging Message Counter....................................................................... 245

Chapter 14..................................................................................247

Abis-Interface Signaling............................................................247 Abis-interface Measurement................................................................. 247

Abis-interface Counters ....................................................................................... 247 Abis-interface Counters Explanation ..................................................................... 248

Chapter 15..................................................................................259

Resource Availability Measurement ..........................................259 Resource Availability Counters............................................................. 259

Resource Availability Counters Explanation ........................................................... 260

Chapter16...................................................................................269

Sub Cell Measurement ...............................................................269 Sub Cell Counters .................................................................................. 269

Sub Cell Counters Explanation ............................................................................. 271

Page 8: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 17..................................................................................287

A-interface Signal Measurement ...............................................287 BSSAP Message Counters ..................................................................... 287

BSSAP Message Counters Explanation.................................................................. 288 BSSMAP Message Counters .................................................................. 289

Chapter 18..................................................................................293

A- Interface Service Measurement............................................293 SMM Assignment Counters ................................................................... 293

Assignment Process............................................................................................ 293 SMM Assignment Counters Explanation ................................................................ 294

SMM Handover in Counters................................................................... 296 SMM Handover in Process ................................................................................... 297 Handover in Counters Explanation........................................................................ 297

SMM Call Drop Counters........................................................................ 300 Call Drop Counters Explanation............................................................................ 300

Chapter19...................................................................................303

SCCP Connection Measurement.................................................303 SCCP Connection Counters ................................................................... 303

SCCP Connection Counters Explanation ................................................................ 304

Chapter 20..................................................................................307

Terrestrial Resources Measurement .........................................307 Trunk Circuit Counters .......................................................................... 307

Trunk Circuit Counters Explanation....................................................................... 307

Chapter 21..................................................................................311

TRX LAPD Link Measurement ....................................................311 LAPD Link Counters............................................................................... 311

LAPD Link Counters Explanation........................................................................... 312

Chapter22...................................................................................317

Processor Load Measurement ...................................................317 RMM Load Counters .............................................................................. 317

RMM Load Counters Explanation .......................................................................... 318 Service Load Counter ............................................................................ 319

Service Load Counter Explanation ........................................................................ 319

Page 9: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

9

Usability Measurement Counter ........................................................... 320 Usability Measurement Counter Explanation.......................................................... 320

SMM Load Counters............................................................................... 320 SMM Load Counters Explanation .......................................................................... 321

File System Load Counters.................................................................... 321

Chapter 23..................................................................................323

Q3 Module Measurement...........................................................323 Q3 Module Counters.............................................................................. 323

Q3 Module Counters Explanation.......................................................................... 324

Chapter 24..................................................................................333

Q3 Cell and BTS Measurement ..................................................333 Q3 Cell and BTS Counters ..................................................................... 333

Chapter 25..................................................................................335

Adjacent Cell Handover Measurement ......................................335 Adjacent Cell Handover Counters......................................................... 335

Intra-MSC Handover........................................................................................... 335 Intra-BSC Handover ........................................................................................... 336 Adjacent Cell Handover Counters Explanation ....................................................... 337

Chapter 26..................................................................................345

Phase-3 NMS Measurement for Cell ..........................................345 Phase-3 NMS Counters.......................................................................... 345

Phase-3 NMS Counters Explanation...................................................................... 347

Chapter 27..................................................................................359

TCH/H Measurement .................................................................359 TCH/H Counters .................................................................................... 359

TCHH Counters Explanation................................................................................. 364

Chapter 28..................................................................................389

Half Rate Statistics.....................................................................389 HR Measurement Counters................................................................... 389

HR Measurement Counters Explanation ................................................................ 392

Chapter 29..................................................................................413

Reserved Channel Measurement...............................................413

Page 10: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Reserved Channel Counters.................................................................. 413 Reserved Channel Counters Explanation............................................................... 413

Chapter 30..................................................................................417

Packet Switched Service Measurement ....................................417 PS Basic Measurement Counters.......................................................... 417

PS Basic Measurement Counters Explanation ........................................................ 421 PS Traffic Counters................................................................................ 462

PS Traffic Counters Explanation............................................................................ 466 Network Service Sub layer Counters.................................................... 500

Network Service Sub layer Counters Explanation................................................... 501 BSSGP Layer Counters .......................................................................... 508

BSSGP Counters Explanation............................................................................... 509 NSE Performance Counters................................................................... 518

NSE Performance Counters Explanation................................................................ 519 Resource Management Counters.......................................................... 529

Resource Management Counters Explanation........................................................ 530

Appendix A .................................................................................541

Abbreviations .............................................................................541

Appendix B .................................................................................545

Tables .........................................................................................545

Appendix C .................................................................................547

Figures........................................................................................547

Appendix D.................................................................................549

Index ..........................................................................................549

Page 11: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION xi

About this Operation Guide

Purpose of this Operation Guide This guide provides information about the ZXG10-BSS Base Station Subsystem Counters.

TAB L E 1 C H AP T E R S S U M M AR Y

Section Summary

Chapter 1, Basic Measurement This chapter describes definition, description and calculation formulas of basic measurement task counters.

Chapter 2, BTS measurement This chapter describes definition, description and measurement points of BTS performance measurement counters. BTS performance measurement includes power control measurement, carrier service measurement, paging measurement and carrier frequency-level basic measurement.

Chapter 3, Cell Wireless Measurement This chapter describes definition, description and measurement points of cell wireless measurement counters.

Chapter 4, Wireless Access Measurement This chapter describes definition, meaning and measurement points of wireless access measurement counters.

Chapter 5, SDCCH Measurement This chapter describes definition, description and measurement points of SDCCH measurement counters.

Chapter 6, TCH/F Measurement This chapter describes definition, description and measurement points of TCH/F measurement counters.

Chapter 7, SAPI 3 Measurement This chapter describes definition, description and measurement points of SAPI 3 measurement. Counters.

Chapter 8, RMM Assignment Measurement

This chapter describes definition, description and measurement points of RMM assignment measurement counters.

Chapter 9, RMM Call Drop Measurement This chapter describes definition, description and measurement points of RMM call drop measurement counters.

Page 12: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

xii Confidential and Proprietary Information of ZTE CORPORATION

Section Summary

Chapter 10, Handover Cause Measurement

This chapter describes the meanings and measurement points of handover cause measurement counters.

Chapter 11, Handover Common Measurement

This chapter describes the meanings and measurement points of handover common measurement counters.

Chapter 12, Handover Synchronous Measurement

This chapter describes the meanings and measurement points of handover synchronous measurement counters.

Chapter 13, Paging Measurement This chapter describes the meanings and measurement points of paging measurement counters.

Chapter 14, Abis-interface Signaling Statistics

This chapter describes the meanings and measurement points of Abis-interface signaling statistics counters.

Chapter 15, Wireless Resource Availability Measurement

This chapter describes the meanings and measurement points of wireless resource availability measurement counters.

Chapter 16, Sub Cell Related Statistics Measurement

This chapter describes sub cell related statistics measurement counters for second sub cell in dual frequency cell.

Chapter 17, A-interface Signaling Measurement

This chapter describes the meanings and measurement points of A-interface signaling statistics measurement counters.

Chapter 18, A-interface Service Measurement

This chapter describes the measurement of Assignment, Call Drop and Handover Statistics at A-interface.

Chapter 19, SCCP Connection Counters This chapter describes SCCP connection counters for SCCP messages that are used to setup an SCCP connection.

Chapter 20, terrestrial Resource Trunk Circuit Measurement

This chapter describes trunk circuit counters for BSC trunk circuits.

Chapter 21, TRX LAPD Link Measurement This chapter describes LAPD link counters for the TRX LAPD board, which transfers the signaling messages to its contiguous layers.

Chapter 22, Processor Load Measurement This chapter describes processor load measurement counters for CPU load, memory consumption, service load and file system load in SMM and RMM.

Chapter 23, Q3 Module Measurement This chapter describes the Q3 module measurement counters.

Chapter 24, Q3 Cell and BTS measurement

This chapter describes the Q3 Cell and Q3 BTS Measurement Counters. These counters provide statistics for received signal level, received signal quality and call distance.

Chapter 25, Adjacent Cell Handover Measurement

This chapter describes the measurement counters for handover between the specified cells and their adjacent cells.

Page 13: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

About this Operation Guide

Confidential and Proprietary Information of ZTE CORPORATION xiii

Section Summary

Chapter 26, Phase-3 NMS Measurement for Cell

This chapter describes counters for phase three NMS – cell basic measurement and measuring points

Chapter 27, TCH/H Measurement This chapter describes TCH/H Measurement Counters.

Chapter 28, HR Statistics This chapter provides statistics for the HR related services and resources.

Chapter 29, Statistic Measurement due to dual frequency on the same cell

This chapter describes statistic measurement counter related to dual frequency on the same-cell and measurement points

Typographical Conventions ZTE documents employ the following typographical conventions.

TAB L E 2 TY P O G R AP H I C AL C O N V E N T I O N S

Typeface Meaning

Italics References to other guides and documents.

“Quotes” Links on screens.

Bold Menus, menu options, input fields, radio button names, check boxes, drop-down lists, dialog box names, window names

Bold, with first

letter capitalized

Keys on the keyboard and buttons on screens

Constant width Text that you type, program code, files and directory names, and function names

[ ] Optional parameters

{ } Mandatory parameters

| Select one of the parameters that are delimited by it

Note: Provides additional information about a certain topic.

Checkpoint: Indicates that a particular step needs to be checked before proceeding further.

Tip: Indicates a suggestion or hint to make things easier or more productive for the reader.

Page 14: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

xiv Confidential and Proprietary Information of ZTE CORPORATION

Mouse Operation Conventions TAB L E 3 M O U S E OP E R AT I O N C O N V E N T I O N S

Typeface Meaning

Click Represents clicking the primary mouse button (usually the left mouse button) once.

Double-click Represents quickly clicking the primary mouse button (usually the left mouse button) twice.

Right-click Represents clicking the secondary mouse button (usually the right mouse button) once.

Drag Represents pressing and holding a mouse button and moving the mouse.

Page 15: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

About this Operation Guide

Confidential and Proprietary Information of ZTE CORPORATION xv

Safety Signs TAB L E 4 S AF E T Y S I G N S

Safety Signs Meaning

Danger: Indicates an imminently hazardous situation, which if not avoided, will result in death or serious injury. This signal word should be limited to only extreme situations.

Warning: Indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury.

Caution: Indicates a potentially hazardous situation, which if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices.

Note: Indicates a potentially hazardous situation, which if not avoided, could result in injuries, equipment damage or interruption of services.

Erosion: Beware of erosion.

Electric shock: There is a risk of electric shock.

Electrostatic: The device may be sensitive to static electricity.

Microwave: Beware of strong electromagnetic field.

Laser: Beware of strong laser beam.

No flammables: No flammables can be stored.

No touching: Do not touch.

No smoking: Smoking is forbidden.

Page 16: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

xvi Confidential and Proprietary Information of ZTE CORPORATION

How to Get in Touch The following sections provide information on how to obtain support for the documentation and the software.

Customer Support If you have problems, questions, comments, or suggestions regarding your product, contact us by e-mail at [email protected]. You can also call our customer support center at (86) 755 26771900 and (86) 800-9830-9830.

Documentation Support ZTE welcomes your comments and suggestions on the quality and usefulness of this document. For further questions, comments, or suggestions on the documentation, you can contact us by e-mail at [email protected]; or you can fax your comments and suggestions to (86) 755 26772236. You can also explore our website at http://support.zte.com.cn, which contains various interesting subjects like documentation, knowledge base, forum and service request.

Page 17: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 1

C h a p t e r 1

Key Performance Indicators

This chapter covers the following topics;

Network Performance Measurement

Network Performance Measurement In GSM, performance of the network can be analyzed through KPIs. KPIs are the specific counters, which represent statistics of overall performance of the network. Network performance judgment such as about resource status, service status or channel quality is possible through these statistics. Statistics comes from the basic measurement of the Control System. Degradation in the performance of the specific cells can be identified in OMCR by analyzing the KPIs. In this way specific problem can be resolved accordingly.

Table 4 lists the entire Key Performance Measurement Counters.

KPI Counters

TAB L E 5 K E Y P E R F O R M AN C E I N D I C AT O R S

Counter No. Counter Definition

C11601 Total number of available SDCCHs

C11602 Total number of unavailable SDCCHs

C11603 Total number of attempts for SDCCH.

C11604 Total number of SDCCH overflows

C11605 Total number of SDCCH call drops

C11606 Total SDCCH busy time

C11607 Total number of available TCHs

C11608 Total number of unavailable TCHs

Page 18: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

2 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C11609 Total number of call attempts of TCHs (excluding handover)

C11610 Total number of overflows of TCHs (excluding handover)

C11611 Total number of call attempts of the TCHs (including handover)

C11612 Total number of overflows of the TCHs (including handover)

C11613 Total number of seizures of TCHs (excluding handover)

C11614 Total number of seizures of TCHs (including handover)

C11615 Total number of TCH call drops

C11616 Total busy time of TCHs

C11617 Total number of handover requests (number of executing handin)

C11618 Total number of successful handovers (number of successful handin)

C11619 Total dual band handover call attempts

C11620 Number of successful dual band handovers

C11621 Number of sending paging messages

C11622 Number of call drops due to wireless link failure

C11623 Number of call drops due to LAPD link failure

C11624 Number of call drops due to handover failure

C11625 Number of random access call attempts

C11626 Number of successful random access

C11627 Maximum number of busy SDCCHs

C11628 Mean number of busy SDCCHs

C11629 Total time of SDCCH congestion

C11630 Maximum number of busy TCH/Fs

C11631 Mean number of busy TCH/Fs

C11632 Total time of TCH/F congestion

C11633 Total number of healthy TRXs

C11634 Number of successful access of emergency calls

C11635 Number of successful access of call re-establishment

C11636 Number of MOC access success

C11637 Number of MTC access success

C11638 Number of LOC access success

C11639 Number of other successful access requests

C11640 Number of SDCCH allocation successes (excluding handover)

C11641 Number of SDCCH allocation failures (excluding handover)

C11642 Number of SDCCH allocation successes (including handover)

C11643 Number of SDCCH allocation failures (including handover)

C11644 Number of successful SDCCH assignments

C11645 Number of failed SDCCH assignments

Page 19: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 3

Counter No. Counter Definition

C11646 Number of successful SDCCH handovers

C11647 Number of failed SDCCH handover with return

C11648 Number of failed SDCCH handover without return

C11649 Number of DTAP messages used as SDCCH uplink point-to-point short messages (SMs)

C11650 Number of DTAP messages used as SDCCH downlink point-to-point short messages (SMs)

C11651 Number of DTAP messages used as FACCH/F uplink point-to-point short messages (SMs)

C11652 Number of DTAP messages used as FACCH/F downlink point-to-point short messages (SMs)

C11653 Number of TCH/F allocation successes (excluding handover)

C11654 Number of TCH/F allocation failures (excluding handover)

C11655 Number of TCH/F allocation successes (including handover)

C11656 Number of TCH/F allocation failures (including handover)

C11657 Number of TCH/F assignment successes

C11658 Number of TCH/F assignment failures

C11659 Number of TCH/F handover successes

C11660 Number of failed TCH/F handover with return

C11661 Number of failed TCH/F handover without return

C11662 Number of assignment queuing attempts

C11663 Number of assignment execution due to queuing

C11664 Total time of successful assignment queuing

C11665 Number of assignment queuing successes

C11666 Number of assignment directed retry attempts

C11667 Number of assignment execution because of directed retry

C11668 Handout executions

C11669 Successful handout times

C11670 Mean number of idle TCHs with interference band 1

C11671 Mean number of idle TCHs with interference band 2

C11672 Mean number of idle TCHs with interference band 3

C11673 Mean number of idle TCHs with interference band 4

C11674 Mean number of idle TCHs with interference band 5

C11675 Intra-cell successful handover times

C11676 Intra-cell failed handover times

C11677 Number of Intra-BSC intra-cell hand in attempts (the actual value is the number of hand in execution)

C11678 Number of successful Intra-BSC intra-cell hand ins

C11679 Number of Intra-BSC intra-cell handout attempts (the actual value is

Page 20: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

4 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

the number of handout execution)

C11680 Number of successful Intra-BSC intra-cell handouts

C11681 Total number of TRXs

C11682 Number of access attempts of emergency calls

C11683 Number of access attempts of call re-establishment

C11684 Number of MOC access attempts

C11685 Number of MTC access attempts

C11686 Number of LOC access attempts

C11687 Number of other access request attempts

C11688 Dual band handout executions

C11689 Number of successful dual band handouts

C11690 Number of access due to location update (statistics establishment indication)

C11691 Number of access due to originating calls (statistics establishment indication)

C11692 Number of access due to paging response (statistics establishment indication)

C11693 Number of access due to call re-establishment (statistics establishment indication)

C11694 Number of access due to IMSI detachment (statistics establishment indication)

C11695 Number of access due to others (statistics establishment indication)

C11696 Total number of call attempts of the TCHs (excluding handover) (signaling)

C11697 Total number of overflows of the TCHs (excluding handover) (signaling)

C11698 Total number of call attempts of the TCHs (including handover) (signaling)

C11699 Total number of overflows of the TCHs (including handover) (signaling)

C116100 Number of TCH/F allocation success (excluding handover) (signaling)

C116101 Number of TCH/F allocation failures (excluding handover) (signaling)

C116102 Number of TCH/F allocation success (including handover) (signaling)

C116103 Number of TCH/F allocation failures (including handover) (signaling)

C116104 Handover attempt due to uplink receiving strength (on TCH/F)

C116105 Handover attempt due to downlink receiving strength (on TCH/F)

C116106 Handover attempt due to uplink interference (on TCH/F)

C116107 Handover attempt due to downlink interference (on TCH/F)

C116108 Handover attempt due to C/I RATIO concentric cells (on TCH/F)

C116109 Handover attempt due to PBGT (on TCH/F)

C116110 Handover attempt due to too large TA (on TCH/F)

Page 21: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 5

Counter No. Counter Definition

C116111 Handover attempt due to uplink quality (on TCH/F)

C116112 Handover attempt due to downlink quality (on TCH/F)

C116113 Handover attempt due to other factors (on TCH/F)

C116114 Number of samples with uplink RQ = 0

C116115 Number of samples with uplink RQ = 1

C116116 Number of samples with uplink RQ = 2

C116117 Number of samples with uplink RQ = 3

C116118 Number of samples with uplink RQ = 4

C116119 Number of samples with uplink RQ = 5

C116120 Number of samples with uplink RQ = 6

C116121 Number of samples with uplink RQ = 7

C116122 Number of samples with downlink RQ = 0

C116123 Number of samples with downlink RQ = 1

C116124 Number of samples with downlink RQ = 2

C116125 Number of samples with downlink RQ = 3

C116126 Number of samples with downlink RQ = 4

C116127 Number of samples with downlink RQ = 5

C116128 Number of samples with downlink RQ = 6

C116129 Number of samples with downlink RQ = 7

C116130 Number of call drops due to inter-BSC handover failure

C116131 Total half rate channel busy time

KPI Counters Explanation C11601 Definition

Number of available SDCCHs

Description

C11601 represents the number of SDCCHs in each cell that can be assigned.

Refer to section Resource Availability Counters for C11501 explanation.

Calculation formula

C11601=C11501

Page 22: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

6 Confidential and Proprietary Information of ZTE CORPORATION

C11602 Definition

Number of unavailable SDCCHs

Description

C11602 represents the number of SDCCHs in each cell that cannot be assigned.

Refer to section Resource Availability Counters for C11502 explanation.

Calculation formula

C11602 = C11502

C11603 Definition

Total number of attempts for SDCCH

Description

C11603 represents the total number of requests for SDCCHs. Request for SDCCH includes all the causes such as normal call origination, location update, call re-establishment, IMSI request, IMSI separation and short messages.

Refer to section SDCCH Counters Explanation for counters (C10101, C10104) explanation.

Measurement Point

Reception of the ‘Channel Request’ message

Calculation formula

C11603 = C10101 + C10104

C11604 Definition

Total number of SDCCH overflows

Description

C11604 represents all the unsuccessful requests for SDCCH due to the limited Radio Resource (RR). Overflow means no channel is available to fulfill the SDCCH request.

Refer to section SDCCH Counters Explanationfor counter (C10103, C10106) explanation.

Calculation formula

C11604= C10103+ C10106

Page 23: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 7

C11605 Definition

Total number of SDCCH call drops

Description

C11605 represents the total number of call drops after SDCCHs assignment and before seizure of TCHs during calls.

Refer to section Call Drop Counters Explanation for counter (C10643) explanation.

Calculation formula

C11605= C10643

C11606 Definition

Total SDCCH busy time

Description

It represents the total time of SDCCH seizure in each cell.

Refer to section Resource Availability Counters Explanation for counter (C11505) explanation.

Calculation formula

C11606=C11505

C11607 Definition

Total number of available TCHs

Description

C11607 represents the number of TCHs that can be assigned in cells. TCHs include the number of TCH/Fs and that of TCH/Hs.

Refer to section Resource Availability Counters Explanation for counters (C11507, C11513) explanation.

Calculation formula

C11607=C11507+C11513

C11608 Definition

Total number of unavailable TCHs

Page 24: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

8 Confidential and Proprietary Information of ZTE CORPORATION

Description

C11608 represents the number of TCHs that can not be assigned in cells. TCHs include the number of TCH/Fs and that of TCH/Hs.

Refer to section Resource Availability Counters Explanation for counters (C11508, C11514) explanation.

Calculation formula

C11608=C11508+C11514

C11609 Definition

Total number of call attempts for TCH (excluding handover)

Description

C11609 represents the total number of calls attempts for TCHs (seizure attempts) after all SDCCHs in cells are seized.

Refer to section TCHF Counters Explanation for C10301, C10320, C10351 and TCHH Counters Explanation for C10401, C10420 and C10451 explanation.

Calculation formula

C11609=C10301+C10320+C10351+C10401+C10420+C10451

C11610 Definition

Total number of unsuccessful assignments due to TCH overflow (excluding handover)

Description

It represents the number of overflows in calls to TCHs after all SDCCHs in cells are seized. Overflows mean TCH setup failures after the calling or called occupies SDCCHs, including the case where TCH is assigned as SDCCH in abnormal early allocation but excluding different handover cases. TCHs comprise TCH/Fs and TCH/Hs.

Calculation formula

C11610=C10303+C10322+C10353+C10403+C10422+C10453

C11611 Definition

Total number of call attempts for TCH (including handover)

Description

Page 25: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 9

It represents the number of call attempts to TCHs after all SDCCHs in cells are seized. Call attempts comprise the calling attempts and called attempts, including the case TCH is assigned as SDCCH in abnormal early allocation and also including different handover cases and direct retries. TCHs comprise TCH/Fs and TCH/Hs.

Refer to sections TCHF Counters Explanation and TCHH Counters Explanation.

Calculation formula

C11611=C11609+C10304+C10323+C10354+C10404+C10423+C10454

C11612 Definition

Total number of unsuccessful assignments due to TCH overflow (including handover)

Description

It represents the number of overflows in calls to TCHs after all SDCCHs in cells are seized. Overflows comprise the TCH setup failures after the calling or called occupies SDCCH. It also includes the case where TCH is assigned as SDCCH in abnormal early allocation and also including different handover and direct retries. TCHs comprise TCH/Fs and TCH/Hs.

Refer to sections TCHF Counters Explanation and TCHH Counters Explanation.

Calculation formula

C11612=C11610+C10306+C10325+C10356+C10406+C10425

+ C10456

C11613 Definition

Total number of TCH seizures (excluding handover)

Description

It represents the number of successful seizures of TCHs (excluding handover), including voice and data seizures. TCHs comprise TCH/Fs and TCH/Hs.

Refer to sections TCHF Counters Explanation and TCHH Counters Explanation.

Calculation formula

C11613=C10302+C10321+C10352+C10402+C10421+C10452.

Page 26: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

10 Confidential and Proprietary Information of ZTE CORPORATION

C11614 Definition

Total number of TCH seizures (including handover)

Description

It represents the number of successful seizures of TCHs (including handover), including voice and data seizures. TCHs comprise TCH/Fs and TCH/Hs.

Refer to sections TCHF Counters Explanation and TCHH Counters Explanation.

Calculation formula

C11614=C11613+C10305+ C10324+ C10355+ C10405+ C10424+

C10455

C11615 Definition

Total number of TCH call drops

Description

It represents call losses due to wireless factors after TCHs are successfully assigned to users. Call losses comprise the call drops during handover and after handover. TCHs comprise TCH/Fs and TCH/Hs.

Refer to sections TCHF Counters Explanation and TCHH Counters Explanation.

Calculation formula

C11615=C10644+C10645

C11616 Definition

Total busy time of TCH

Description

It represents the total traffic of all TCHs in this system. TCHs comprise TCH/Fs and TCH/Hs.

Refer to the Section Resource Availability Counters

Calculation formula

C11616=C11511+C11517

Page 27: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 11

C11617 Definition

Total number of handover requests

Description

It represents the total number of requests for handover between cells in the same BSC and between those in different BSCs. Requests for handing into cells is measured.

Refer to the Section Handover Counters Explanation

Calculation formula

C11617=C10912+C10915+C10917+C10919+C10982

C11618 Definition

Total number of successful handovers

Description

It represents the total number of successful handovers between cells in the same BSC and between those in different BSCs. Number of successful handing into cells is measured.

Refer to the Section Handover Counters Explanation

Calculation formula

C11618=C10913+C10920+C10982

C11619 Definition

Total dual-band handover attempts

Description

It represents the number of attempts of handover between the GSM 900 system and the GSM 1800 system, including handover both in the same layer and between different layers.

Refer to the Section Handover Counters Explanation

Calculation formula

C11619=C10934+C10939+C10952+C10957+C10962+C10967+

C15972+ C15977

Page 28: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

12 Confidential and Proprietary Information of ZTE CORPORATION

C11620 Definition

Total number of successful dual-band handovers in busy time

Description

It represents the number of successful handovers between the GSM900 system and the GSM1800 system, including handovers both in the same layer and between different layers.

Refer to the Section Handover Counters Explanation

Calculation formula

C11620= C10935+ C10940+ C10953+ C10958+ C10963+ C10968

+ C15973+ C15978

C11621 Definition

Total number of paging messages

Description

It represents the number of cells sending paging messages.

Refer to the Section Paging Messages Measurement Counters

Calculation formula

C11621= C11301

C11622 Definition

Number of call drops due to wireless link failure

Description

It represents the number of call drops due to wireless link failure, including voice and data. Call drops comprise those on TCH/Fs and those on TCH/Hs.

Refer to section Call Drop Counters Explanation for counters (C10608, C10614, C10620, C10626, C10632 and C10638) explanation.

Calculation formula

C11622=C10608+C10614+C10620+C10626+C10632+C10638

C11623 Definition

Number of call drops due to LAPD link failure

Page 29: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 13

Description

It represents the number of call drops due to LAPD link breakage, including voice and data. Call drops comprise those on TCH/Fs and those on TCH/Hs.

Refer Call Drop Counters Explanation for counters (C10609, C10615, C10621, C10627, C10633 and C10639) explanation.

Calculation formula

C11623=C10609+C10615+C10621+C10627+C10633+C10639

C11624 Definition

Number of call drops due to handover failure

Description

It represents the number of call drops due to handover failure, including voice and data. Call drops comprise those on SDCCHs, TCH/Fs and TCH/Hs.

Refer to section Call Drop Counters Explanation for counters (C10646, C10647, C10648, C10649, C10650, C10651 and C10652) explanation.

Calculation formula

C11624=C10646+C10647+C10648+C10649+C10650+C10651

+C10652

C11625 Definition

Number of requests on RACH

Description

Refer to the description of the counter in section SDCCH Counters Explanation.

Calculation formula

C11625 = C10101

C11626 Definition

Number of successful requests on RACH

Description

Refer to the description of the counter (C10102) in Section SDCCH Counters Explanation.

Page 30: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

14 Confidential and Proprietary Information of ZTE CORPORATION

Calculation formula

C11626 = C10102

C11627 Definition

Maximum number of busy SDCCHs

Description

Refer to the description of the counter (C11503) in Section Resource Availability Counters Explanation.

Calculation formula

C11627 = C11503

C11628 Definition

Mean number of busy SDCCHs

Description

Refer to the description of the counter (C11504) in Section Resource Availability Counters Explanation.

Calculation formula

C11628 = C11504

C11629 Definition

Total SDCCH congestion time

Description

Refer to the description of the counter (C11506) in Section Resource Availability Counters Explanation.

Calculation formula

C11629 = C11506

C11630 Definition

Maximum number of busy TCH/Fs

Description

Refer to the description of the counter (C11515) in Section Resource Availability Counters Explanation.

Page 31: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 15

Calculation formula

C11630 = C11515

C11631 Definition

Mean number of busy TCH/Fs

Description

Refer to the description of the counter (C11516) in Section Resource Availability Counters Explanation.

Calculation formula

C11631 = C11516

C11632 Definition

Total TCH/F congestion time

Description

Refer to the description of the counter (C11518) in Section Resource Availability Counters Explanation.

Calculation formula

C11632 = C11518

C11633 Definition

Total number of healthy TRXs

Description

Refer to the description of the counter (C11520) in Section Resource Availability Counters Explanation.

Calculation formula

C11633 = C11520

C11634 Definition

Number of successful accesses for emergency calls

Description

Refer to the description of the counter C10013 in Section Random Access Counters Explanation.

Page 32: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

16 Confidential and Proprietary Information of ZTE CORPORATION

Calculation formula

C11634 = C10013

C11635 Definition

Number of successful accesses for call re-establishment

Description

Refer to the description of the counter C10010 in Section Random Access Counters Explanation.

Calculation formula

C11635 = C10010

C11636 Definition

Number of successful MOC accesses

Description

Refer to the description of the counter C10014 in Section Random Access Counters Explanation.

Calculation formula

C11636 = C10004

C11637 Definition

Number of successful MTC accesses

Description

Refer to the description of the counter C10007 in Section Random Access Counters Explanation.

Calculation formula

C11637 = C10007

C11638 Definition

Number of LOC access success

Description

Refer to the description of the counter C10016 in Section Random Access Counters Explanation.

Page 33: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 17

.

Calculation formula

C11638 = C10016

C11639 Definition

Number of other successful access requests

Description

Refer to the description of the counter C10019 in Section Random Access Counters Explanation.

Calculation formula

C11639 = C10019

C11640 Definition

Number of successful SDCCH allocations (excluding handover)

Description

Refer to the description of the counter C10108 in Section SDCCH Counters Explanation.

Calculation formula

C11640 = C10108

C11641 Definition

Number of SDCCH allocation failures (excluding handover)

Description

Refer to the description of the counter (C10109) in Section SDCCH Counters Explanation.

Calculation formula

C11641 = C10109

C11642 Definition

Number of SDCCH allocation successes (including handover)

Description

Page 34: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

18 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of the counter (C10111) in Section SDCCH Counters Explanation.

Calculation formula

C11642 = C11640 + C10111

C11643 Definition

Number of SDCCH allocation failures (including handover)

Description

Refer to the description of the counter (C10112) in Section SDCCH Counters Explanation.

Calculation formula

C11643 = C11641 + C10112

C11644 Definition

Number of successful SDCCH assignments

Description

Refer to the description of the counter (C10114) in Section SDCCH Counters Explanation.

Calculation formula

C11644 = C10114

C11645 Definition

Number of unsuccessful SDCCH assignments

Description

Refer to the description of the counter (C10115) in Section SDCCH Counters Explanation.

Calculation formula

C11645 = C10115

C11646 Definition

Number of successful SDCCH handovers

Description

Page 35: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 19

Refer to the description of the counter (C10117) in Section SDCCH Counters Explanation.

Calculation formula

C11646 = C10117

C11647 Definition

Number of unsuccessful SDCCH handover with return

Description

Refer to the description of the counter (C10117) in Section SDCCH Counters Explanation.

Calculation formula

C11647 = C10118

C11648 Definition

Number of failed SDCCH handover without return

Description

Refer to the description of the counter (C10119) in Section SDCCH Counters Explanation.

Calculation formula

C11648 = C10119

C11649 Definition

Number of DTAP messages used as SDCCH uplink point-to-point short messages (SMs)

Description

Refer to the description of the counter C10216 in Section SAPI 3 Counters Explanation

Calculation formula

C11649 = C10216

C11650 Definition

Number of DTAP messages used as SDCCH downlink point-to-point short messages (SMs)

Page 36: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

20 Confidential and Proprietary Information of ZTE CORPORATION

Definition

Refer to the description of the counter (C10217) in Section SAPI 3 Counters Explanation

Calculation formula

C11650 = C10217

C11651 Definition

Number of DTAP messages used as FACCH/F uplink point-to-point short messages (SMs)

Description

Refer to the description of the counter C10218 in Section SAPI 3 Counters Explanation

Calculation formula

C11651 = C10218

C11652 Definition

Number of DTAP messages used as FACCH/F downlink point-to-point short messages (SMs)

Description

Refer to the description of the counter (C10219) in Section SAPI 3 Counters Explanation

Calculation formula

C11652 = C10219

C11653 Definition

Number of TCH/F allocation successes (excluding handover)

Description

It represents the number of receiving activation response messages after channels are activated in assigning TCH/Fs for assignment (signaling, voice and data).

Refer to the description of the counters C10308, C10327, C10333, C10339 and C10358 in section TCHF Counters Explanation.

Calculation formula

C11653 = C10308 + C10327 + C10333 + C10339 +C10358

Page 37: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 21

C11654 Definition

Number of TCH/F allocation failures (excluding handover)

Description

It represents the number negative replies in response TCH/F activation request for assignment (signaling, voice and data).

Refer to the description of the counters C10309, C10328, C10334, C10340 and C10359 in section TCHF Counters Explanation.

Calculation formula

C11654 = C10309 + C10328 + C10334 + C10340 + C10359

C11655 Definition

Number of TCH/F allocation successes (including handover)

Description

It represents the number of receiving activation response messages after channels are activated in assigning and hand over to TCH/Fs (voice and data).

Refer to the description of the counters C10311, C10330, C10336, C10342 and C10361 in Section TCHF Counters Explanation.

Calculation formula

C11655 = C11653 + C10311 + C10330 + C10336 + C10342 +

C10361

C11656 Definition

Number of TCH/F allocation failures (including handover)

Description

It represents the number negative replies in response of TCH/F activation request for assignment and handover (voice and data).

Refer to the description of the counters C10312, C10331, C10337, C10343 and C10362 in section TCHF Counters Explanation.

Calculation formula

C11656 = C11654 + C10312 + C10331 + C10337 + C10343 +

C10362

Page 38: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

22 Confidential and Proprietary Information of ZTE CORPORATION

C11657 Definition

Number of TCH/F assignment successes

Description

It represents the number of receiving Establish Indication or Assignment Complete messages after TCH/F assignment command (signaling, voice and data).

Refer to the description of the counters C10314, C10345 and C10364 in section TCHF Counters Explanation.

Calculation formula

C11657 = C10314 + C10345 +C10364

C11658 Definition

Number of TCH/F assignment failures

Description

It represents the number negative replies in response of TCH/F Assignment Command (signaling, voice and data).

Refer to the description of the counter C10315, C10346 and C10365 in section TCHF Counters Explanation.

Calculation formula

C11658 = C10315 + C10346 +C10365

C11659 Definition

Number of TCH/F handover successes

Description

It represents the number of successful TCH/F handovers after receiving the handover complete or assignment complete messages (signaling, voice and data).

Refer to the description of the counters C10317, C10348 and C10367 in section TCHF Counters Explanation.

Calculation formula

C11659 = C10317 + C10348 +C10367

Page 39: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 23

C11660 Definition

Number of failed TCH/F handover with return

Description

It represents the number of receiving the handover failure or assignment failure messages during TCH/Fs handover (signaling, voice and data).

Refer to the description of the counters C10318, C10349 and C10368 in section TCHF Counters Explanation.

Calculation formula

C11660 = C10318 + C10349 +C10368

C11661 Definition

Number of failed TCH/F handover without return

Description

It represents the number of not receiving the handover failure or assignment failure messages during TCH/Fs handover (signaling, voice and data).

Refer to the description of the counters C10319, C10350 and C10369 in section TCHF Counters Explanation.

Calculation formula

C11661 = C10319 + C10350 +C10369

C11662 Definition

Number of assignment queuing attempts

Description

It represents the number of queuing for resources after voice and data services fail to apply for resources.

Refer to the description of the counter C10504 and C10513 in Section RMM Assignment Counters Explanation

Calculation formula

Page 40: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

24 Confidential and Proprietary Information of ZTE CORPORATION

C11662 = C10504 + C10513

C11663 Definition

Number of successful assignments after queuing

Description

It represents the number of successful assignments after queuing for voice and data channel.

Refer to the description of the counters C10505 and C10514 in Section RMM Assignment Counters Explanation

Calculation formula

C11663 = C10505 + C10514

C11664 Definition

Total time of successful assignment queuing

Description

It represents the total time for voice and data services queue to obtain channels.

Refer to the description of the counter C10506 and C10515 in Section RMM Assignment Counters Explanation.

Calculation formula

C11664 = C10506 + C10515

C11665 Definition

Number of assignment queuing successes

Description

It represents the number of successful channel assignments after queuing (voice and data channels).

Calculation formula

C11665 = C10507 + C10516

C11666 Definition

Number of assignment attempts for direct retry

Description

Page 41: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 25

It represents the number of voice and data assignment attempts for directed retry.

Refer to the description of the counter C10508 and C10517 in Section RMM Assignment Counters Explanation.

Calculation formula

C11666 = C10508 + C10517

C11667 Definition

Number of assignment execution because of directed retry

Description

It represents the number of voice and data assignment executions for directed retry.

Refer to the description of the counters C10509 and C10518 in RMM Assignment Counters Explanation.

Calculation formula

C11667 = C10509 + C10518

C11668 Definition

Handover out executions

Description

It represents the total number of handover out executions for intra-cell handover, Intra-BSC inter-cell handover and Intra-MSC inter-cell handover.

Refer to the description of the counter C10902, C10909 and C10982 in Section Handover Counters Explanation.

Calculation formula

C11668 = C10902 + C10909 +C10982

C11669 Definition

Number of successful handover outs

Description

It represents the total number of successful handover outs for intra-cell handover, Intra-BSC inter-cell handover and Intra-MSC inter-cell handover.

Page 42: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

26 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of the counter C10903, C10910 and C10982 in Section Handover Counters Explanation.

Calculation formula

C11669 = C10903 + C10910 +C10982

C11670 Definition

Mean number of idle TCHs with interference band 1

Description

It represents the total mean number ofidle TCH/Fs and TCH/Hs with interference band 1.

Refer to the description of the counters C10719 and C10725 in Section Channels Counters Explanation.

Calculation formula

C11670 = C10719 + C10725

C11671 Definition

Mean number of idle TCHs with interference band two

Description

It represents the total mean number of idle TCH/Fs and TCH/Hs with interference band 2.

Refer to the description of the counters C10720 and C10726 in Section Channels Counters Explanation.

Calculation formula

C11671 = C10720 + C10726

C11672 Definition

Mean number of idle TCHs with interference band three

Description

It represents the total mean number of idle TCH/Fs and TCH/Hs with interference band 3.

Refer to the description of the counters C10721 and C10727 in Section Channels Counters Explanation.

Calculation formula

C11672 = C10721 + C10727

Page 43: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 27

C11673 Definition

Mean number of idle TCHs with interference band four

Description

It represents the total Mean number of idle TCH/Fs and TCH/Hs with interference band 4.

Refer to the description of the counter C10722 and C10728 in Section Channels Counters Explanation.

Calculation formula

C11673 = C10722 + C10728

C11674 Definition

Mean number of idle TCHs with interference band five

Description

It represents the total mean number of idle TCH/Fs and TCH/Hs with interference band five.

Refer to the description of the counter C10723 and C10729 in Section Channels Counters Explanation.

Calculation formula

C11674 = C10723 + C10729

C11675 Definition

Number of successful Intra-cell handovers.

Description

Refer to the description of the counter C10982 in Section Handover Counters Explanation

Calculation formula

C11675 = C10982

C11676 Definition

Number of Intra-cell handover failures.

Description

It represents the number of intra-cell handover failures.

Page 44: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

28 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of the counter C10981 and C10982 in Section Handover Counters Explanation

Calculation formula

C11676 = C10981 - C10982

C11677 Definition

Number of intra-BSC handover in attempts

Description

Refer to the description of the counter C10912 in Section Handover Counters Explanation

Calculation formula

C11677 = C10912

C11678 Definition

Number of successful Intra-BSC intra-cell handover in

Description

Refer to the description of the counter C10913 in Section Handover Counters Explanation

Calculation formula

C11678 = C10913

C11679 Definition

Number of Intra-BSC intra-cell handout attempts

Description

Refer to the description of the counter C10902 in Section Handover Counters Explanation

Calculation formula

C11679 = C10902

C11680 Definition

Number of successful Intra-BSC intra-cell handouts

Description

Page 45: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 29

Refer to the description of the counter C10903 in Section Handover Counters Explanation.

Calculation formula

C11680 = C10903

C11681 Definition

Total number of TRXs

Description

Refer to the description of the counter C11519.

Calculation formula

C11681 = C11519

C11682 Definition

Number of access attempts of emergency calls

Description

Refer to the description of the counter C10011 in Section Random Access Counters Explanation.

Calculation formula

C11682 = C10011

C11683 Definition

Number of access attempts of call re-establishment

Description

Refer to the description of the counter C10008 in Section Random Access Counters Explanation.

Calculation formula

C11683 = C10008

C11684 Definition

Number of MOC access attempts

Description

Page 46: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

30 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of the counter C10002 in Section Random Access Counters Explanation.

Calculation formula

C11684 = C10002

C11685 Definition

Number of MTC access attempts

Description

Refer to the description of the counter C10005 in Section Random Access Counters Explanation.

Calculation formula

C11685 = C10005

C11686 Definition

Number of LOC access attempts

Description

Refer to the description of the counter C10014 in Section Random Access Counters Explanation.

Calculation formula

C11686 = C10014

C11687 Definition

Number of other access request attempts

Description

Refer to the description of the counter C10017 in Section Random Access Counters Explanation.

Calculation formula

C11687 = C10017

C11688 Definition

Number of dual band handover out attempts

Description

Page 47: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 31

It represents the number of handover from the GSM 900 to the GSM 1800 and handover from the GSM 1800 to GSM 900.

Refer to the description of the counter C10991 and C10992 in Section Handover Counters Explanation.

Calculation formula

C11688 = C10991 + C10992

C11689 Definition

Number of successful dual band handover outs.

Description

It represents the number of successful handover from the GSM 900 to the GSM 1800 and successful handover from the GSM 1800 to the GSM 900.

Refer to the description of the counters C10937, C10942, C10955, C10960, C10965, C10970, C10975 and C10980 in Section Handover Counters Explanation.

Calculation formula

C11689 = C10937 + C10942 + C10955 + C10960 + C10965 + C10970 + C10975 + C10980

C11690 Definition

Number of accesses due to location updates (statistics establishment indication)

Description

Refer to the description of the counter C10020 in Section Random Access Counters Explanation.

Calculation formula

C11690 = C10020

C11691 Definition

Number of accesses due to call origination (statistics establishment indication)

Description

Refer to the description of the counter C10021 in Section Random Access Counters Explanation.

Page 48: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

32 Confidential and Proprietary Information of ZTE CORPORATION

Calculation formula

C11691 = C10021

C11692 Definition

Number of accesses due to paging response (statistics establishment indication)

Description

Refer to the description of the counter C10022 in Section Random Access Counters Explanation.

Calculation formula

C11692 = C10022

C11693 Definition

Number of accesses due to call re-establishment (statistics establishment indication)

Description

Refer to the description of the counter C10023 in Section Random Access Counters Explanation.

Calculation formula

C11693 = C10023

C11694 Definition

Number of access due to IMSI detachment (statistics establishment indication)

Description

Refer to the description of the counter C10024 in Section Random Access Counters Explanation.

Calculation formula

C11694 = C10024

C11695 Definition

Number of access due to others (statistics establishment indication)

Description

Page 49: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 33

Refer to the description of the counter C10025 in Section Random Access Counters Explanation.

Calculation formula

C11695 = C10025

C11696 Definition

Number of call attempts on TCH (signaling) (excluding handover)

Description

It represents the total number of call attempts on TCH/Fs and TCH/Hs for signaling assignment.

Refer to the description of the counter C10301 and C10401 in Section TCHF Counters Explanation

Calculation formula

C11696 = C10301 + C10401

C11697 Definition

Total number of overflows of the TCHs (excluding handover) (signaling)

Description

It represents the total number of failures in call attempt for TCH/Fs and TCH/Hs for signaling assignment.

Refer to the sections TCHH Counters Explanation and Channels Counters Explanation.

Calculation formula

C11697 = C10303 + C10403

C11698 Definition

Total number of TCHs call attempts (including handover) (signaling)

Description

It represents the total number of call attempts on TCH/Fs and TCH/Hs for signaling assignment and handover.

Calculation formula

C11698 = C11696 + C10304 +C10404

Page 50: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

34 Confidential and Proprietary Information of ZTE CORPORATION

C11699 Definition

Total number of overflows of the TCHs (including handover) (signaling)

Description

It represents the total number of failures in call attempt applying for channels on TCH/Fs and TCH/Hs for signaling assignment and handover.

Calculation formula

C11699 = C11697 + C10306 +C10406

C116100 Definition

Number of successful TCH/F allocation (excluding handover) (signaling)

Description

Refer to the description of the counter C10308 in Section TCHF Counters Explanation.

Calculation formula

C116100 = C10308

C116101 Definition

Number of TCH/F allocation failure (excluding handover) (signaling)

Description

Refer to the description of the counter C10309 in Section TCHF Counters Explanation.

Calculation formula

C116101 = C10309

C116102 Definition

Number of TCH/F allocation success (including handover) (signaling)

Description

It represents the number of TCH/F allocation success for assignment and handover.

Refer to counter C116100 and explanation of the counter C10311 in Section TCHF Counters Explanation.

Page 51: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 35

Calculation formula

C116102 = C116100 + C10311

C116103 Definition

Number of TCH/F allocation failure (including handover) (signaling)

Description

It represents the number of TCH/F allocation failures for assignment and handover.

Refer to the counter C116101 and the description of the counter C10312 in Section TCHF Counters Explanation.

Calculation formula

C116103 = C116101 + C10312

C116104 Definition

Handover attempt due to uplink receiving strength (on TCH/F)

Description

Refer to the description of the counter C10812 in Section Handover Cause Counters Explanation.

Calculation formula

C116104 = C10812

C116105 Definition

Handover attempt due to downlink receiving level(on TCH/F)

Description

Refer to the description of the counter C10813 in Section Handover Cause Counters Explanation.

Calculation formula

C116105 = C10813

C116106 Definition

Handover attempt due to uplink interference (on TCH/F)

Description

Page 52: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

36 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of the counter C10814 in Section Handover Cause Counters Explanation.

Calculation formula

C116106 = C10814

C116107 Definition

Handover attempt due to downlink interference (on TCH/F)

Description

Refer C10815.

Calculation formula

C116107 = C10815

C116108 Description

Handover attempt due to C/I RATIO concentric cells (on TCH/F)

Definition

Refer to the description of the counter C10814 in Section Handover Cause Counters Explanation.

Calculation formula

C116108 = C10816

C116109 Definition

Handover attempt due to PBGT (on TCH/F)

Description

Refer to the description of the counter C10817 in Section Handover Cause Counters Explanation.

Calculation formula

C116109 = C10817

C116110 Definition

Handover attempt due to large TA (on TCH/F)

Description

Page 53: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 1 - Key Performance Indicators

Confidential and Proprietary Information of ZTE CORPORATION 37

Refer to the description of the counter C10818 in Section Handover Cause Counters Explanation.

Calculation formula

C116110 = C10818

C116111 Definition

Handover attempt due to uplink quality (on TCH/F)

Description

Refer to the description of the counter C10836 in Section Handover Cause Counters Explanation.

Calculation formula

C116111 = C10836

C116112 Definition

Handover attempt due to downlink quality (on TCH/F)

Description

Refer to the description of the counter C10837 in Section Handover Cause Counters Explanation.

Calculation formula

C116112 = C10837

C116113 Definition

Handover attempt due to other factors (on TCH/F)

Description

Refer to the description of the counter C10821 in Section Handover Cause Counters Explanation.

Calculation formula

C116113 = C10821

C116114 Definition

Number of uplink signal samples with RQ = 0

Description

Page 54: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

38 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of the counter C10821 in Section Handover Cause Counters Explanation.

Calculation formula

C116114 = C10821

C116130 Definition

Number of call drops due to inter-BSC handover failure

Description

It represents the number of call drops due to Intra-MSC inter-cell handover failure. It is the number of call drops due to all handover minus call drops due to intra-BSC handover.

Refer to the description of the counter C11715 in Section TCHF Counters Explanation.

Calculation formula

C116130 = C11624 - C11715

C116131 Definition

Total TCH/H busy time

Description

It represents total seize time of each TCH/H in a cell. Total number of seize TCH/H in a cell shows TCH/H traffic in that cell.

Refer to the description of the counter C11715 in Section Resource Availability Counters Explanation.

Calculation formula

C116131 = C11511

Page 55: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 39

C h a p t e r 2

BTS Measurement

This chapter covers the following topics:

Power Control Measurement

TRX Service Measurement

Paging Messages Measurement

TRX Basic Measurement

TRX Power & Temperature Measurement

Power Control Measurement Power Control enables the mobile station and/or the BTS to increase or decrease the transmission power on a per-radio link basis.

Power Control is separately performed for the uplink and downlink. In both cases the BSC is responsible for initiating Power Control; the mobile station and the BTS adopt transmit power according to the BSC Power Control commands.

Two modes of power control are:

Normal power control

Rapid power control

Amplitude of power adjustment in rapid control is greater than normal power control.

BTS regularly samples the power of MS and BTS itself, to obtain average power. BTS regularly reports the average power to BSC through PC TEST RPT message, for power control. Measurement report helps in analyzing the coverage quality as well as the effect and rate of power control.

Page 56: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

40 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 1 - P O W E R C O N T R O L P R O C E S S

A1

BSCBTS: TRXMS

Power control for TRX

PC TEST RPT

Power control for MS

A2

B1

Regularly scanpower of MS and

BTS

A3

Table 6 lists power control measurement counters.

Power Control Counters

TAB L E 6 P O W E R C O N T R O L C O U N T E R S

Counter No. Counter definition

C00001 Number of normal increase in MS power due to uplink signal level

C00002 Number of rapid increase in MS power due to uplink signal level

C00003 Number of normal decrease in MS power due to uplink signal level

C00004 Number of rapid decrease in MS power due to uplink signal level

C00005 Number of normal increase in BTS power due to downlink signal level

C00006 Number of rapid increase in BTS power due to downlink signal level

C00007 Number of normal decrease in BTS power due to downlink signal level

C00008 Number of rapid decrease in power BTS due to downlink signal level

C00009 Number of normal increase in MS power due to uplink signal quality

C00010 Number of rapid increase in MS power due to uplink signal quality

C00011 Number of normal decrease in MS power due to uplink signal quality

C00012 Number of rapid decrease in MS power due to uplink signal quality

Page 57: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 41

Counter No. Counter definition

C00013 Number of normal increase in BTS power due to downlink signal quality

C00014 Number of rapid increase in BTS power due to downlink signal quality

C00015 Number of normal decrease in BTS power due to downlink signal quality

C00016 Number of rapid decrease in BTS power due to downlink signal quality

C00017 Total value of power scans of MS transmitting power

C00018 Number of power scans of MS transmitting power

C00019 Total value of power scans of BTS power

C00020 Number of power scans of BTS power

C00021 Total value of power scans of downlink signal level

C00022 Number of power scans of downlink signal level

C00023 Total value of power scans of uplink signal level

C00024 Number of power scans of uplink signal level

C00025 Total value of power scans of downlink signal quality

C00026 Number of power scans of downlink signal quality

C00027 Total value of power scans of uplink signal quality

C00028 Number of power scans of uplink signal quality

Power Control Counters Explanation C00001 Definition

Number of normal increase in MS power due to uplink signal level

Description

BTS periodically measures the uplink signal level. It calculates average level value and sends this value to BSC. BSC compares the average level value with threshold value and decides normal increase in MS power according to the power control algorithm.

Measurement point

Normal increase in MS power at point A1 in FIGURE 1

C00002 Definition

Number of rapid increase in MS power due to uplink signal level

Description

Page 58: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

42 Confidential and Proprietary Information of ZTE CORPORATION

BTS periodically measures the uplink signal level. It calculates average level value and sends this value to BSC. BSC compares the average level value with threshold value and decides rapid increase in MS power according to the power control algorithm.

Measurement point

Rapid increase in MS power at point A1 in FIGURE 1

C00003 Definition

Number of normal decrease in MS power due to uplink signal level

Description

BTS periodically measures the uplink signal level. It calculates average level value and sends this value to BSC. BSC compares the average level value with threshold value and decides normal decrease in MS power according to the power control algorithm.

Measurement point

Normal decrease in MS power at point A1 in FIGURE 1

C00004 Definition

Number of rapid decrease in MS power due to uplink signal level

Description

BTS periodically measures the uplink signal level. It calculates average level value and sends this value to BSC. BSC compares the average level value with threshold value and decides rapid decrease in MS power according to the power control algorithm.

Measurement point

Rapid decrease in MS power at point A1 in FIGURE 1

C00005 Definition

Number of normal increase in BTS power due to downlink signal level

Description

BTS periodically receives measurement report of downlink signal level. BSC compares the average level value with the threshold value and decides normal increase in BTS power according to the power control algorithm.

Page 59: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 43

Measurement point

Normal increase in BTS power at point A2 in FIGURE 1

C00006 Definition

Number of rapid increase in BTS power due to downlink signal level

Description

BTS periodically receives measurement report of downlink signal level. BSC compares the average level value with the threshold value and decides rapid increase in BTS power according to the power control algorithm.

Measurement point

Rapid increase in BTS power at point A2 in FIGURE 1

C00007 Definition

Number of normal decrease in BTS power due to downlink signal level

Description

BTS periodically receives measurement report of downlink signal level. BSC compares the average level value with the threshold value and decides normal decrease in BTS power according to the power control algorithm.

Measurement point

Normal decrease in BTS power at point A2 in FIGURE 1

C00008 Definition

Number of rapid decrease in BTS power due to downlink signal level

Definition

BTS periodically receives measurement report of downlink signal level. BSC compares the average level value with the threshold value and decides rapid decrease in BTS power according to the power control algorithm.

Measurement point

Rapid decrease in BTS power at point A2 in FIGURE 1

Page 60: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

44 Confidential and Proprietary Information of ZTE CORPORATION

C00009 Definition

Number of normal increase in MS power due to uplink signal quality

Description

BTS periodically measures the uplink signal quality. It calculates average quality value and sends this value to BSC. BSC compares the average quality value with threshold value and decides normal increase in MS power according to the power control algorithm.

Measurement point

Normal increase in MS power at point A1 in FIGURE 1

C00010 Definition

Number of rapid increase in MS power due to uplink signal quality

Description

BTS periodically measures the uplink signal quality. It calculates average quality value and sends this value to BSC. BSC compares the average quality value with threshold value and decides rapid increase in MS power according to the power control algorithm.

Measurement Point

Rapid increase in MS power at point A1 in FIGURE 1

C00011 Definition

Number of normal decrease in MS power due to uplink signal quality

Description

BTS periodically measures the uplink signal quality. It calculates average quality value and sends this value to BSC. BSC compares the average quality value with threshold value and decides normal decrease in MS power according to the power control algorithm.

Measurement Point

Normal decrease in MS power at point A1 in FIGURE 1

C00012 Definition

Number of rapid decrease in MS power due to uplink signal quality

Page 61: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 45

Description

BTS periodically measures the uplink signal quality. It calculates average quality value and sends this value to BSC. BSC compares the average quality value with threshold value and decides rapid decrease in MS power according to the power control algorithm.

Measurement Point

Rapid decrease in MS power at point A1 in FIGURE 1

C00013 Definition

Number of normal increase in BTS power due to downlink signal quality

Description

BTS periodically receives measurement report of downlink signal quality from MS. BSC compares the average of received measurement values with threshold value and decides normal increase in BTS power according to the power control algorithm.

Measurement Point

Normal increase in BTS power at point A2 in FIGURE 1

C00014 Definition

Number of rapid increase in BTS power due to downlink signal quality

Description

BTS periodically receives measurement report of downlink signal quality from MS. BSC compares the average of received measurement values with threshold value and decides rapid increase in BTS power according to the power control algorithm.

Measurement Point

Rapid increase in BTS power at point A2 in FIGURE 1

C00015 Definition

Number of normal decrease in BTS power due to downlink signal quality

Description

BTS periodically receives measurement report of downlink signal quality from MS. BSC compares the average of received measurement values with threshold value and decides normal decrease in BTS power according to the power control algorithm.

Page 62: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

46 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Normal decrease Rapid increase in BTS power at point A2 in FIGURE 1

C00016 Definition

Number of rapid decrease in BTS power due to downlink signal quality

Description

BTS periodically receives measurement report of downlink signal quality from MS. BSC compares the average of received measurement values with threshold value and decides rapid decrease in BTS power according to the power control algorithm.

Measurement Point

Rapid decrease Rapid increase in BTS power at point A2 in FIGURE 1

C00017 Definition

Total value of power scans of MS transmitting power

Description

BTS periodically measures the MS transmitting power and accumulates each power scan value in this counter. Value of this counter is used to calculate the average value, which BTS sends to BSC for power control.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00018 Definition

Number of power scans of MS transmitting power

Description

BTS periodically measures the MS transmitting power. This counter represents the number of power scans of MS transmitting power. Each time BTS accumulates the power scan values, value of this counter increment by one.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

Page 63: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 47

C00019 Definition

Total value of power scans of BTS power

Description

BTS periodically measures its own power and accumulates the power scan values in this counter. Value of this counter is used to calculate the average value, which BTS sends to BSC for power control.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00020 Definition

Number of power scans of BTS power

Description

BTS periodically measures its own power. This counter represents the number of BTS power scans. Each time BTS accumulates the power scan values, this counter increment by one.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00021 Definition

Total value of power scans of downlink signal level

Description

BTS periodically measures the downlink signal level through information received from MS. MS sends the received signal level information to BTS for power control. This counter contains total value of number of downlink power scans.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00022 Definition

Number of power scans of downlink signal level

Description

BTS periodically measures the downlink signal level through information received from MS. MS sends the received signal level

Page 64: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

48 Confidential and Proprietary Information of ZTE CORPORATION

information to BTS for power control. This counter represents the number of downlink power scans. Each time BTS accumulates the power scan values, value of this counter increment by one.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00023 Definition

Total value of power scans of uplink signal level

Description

BTS periodically measures the uplink signal level and accumulates all the power scan values in this counter. Value of this counter is used to calculate the average power, which BTS sends to BSC for power control.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00024 Definition

Number of power scans of uplink signal level

Description

BTS periodically measures the uplink signal level. This counter represents the number of uplink power scans to measure uplink signal level. Each time BTS accumulates the power scan values, value of this counter increment by one.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00025 Definition

Total value of power scans of downlink signal quality

Description

BTS periodically measures the downlink signal quality through information received from MS. MS send the received signal quality information to BTS for power control. This counter represents the number of downlink power scans. Each time BTS accumulates the power scan values, value of this counter increment by one.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

Page 65: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 49

C00026 Definition

Number of power scans of downlink signal quality

Description

BTS periodically measures the downlink signal quality through information received from MS. MS send the received signal quality information to BTS for power control. This counter represents the number of downlink power scans. Each time BTS accumulates the power scan values, value of this counter increment by one.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00027 Definition

Total value of power scans of uplink signal quality

Description

BTS periodically measures the uplink signal quality and accumulates all the power scan values in this counter. Value of this counter is used to calculate the average power, which BTS sends to BSC for power control.

Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00028 Number of power scans of uplink signal quality

Description

BTS periodically measures the uplink signal quality. This counter represents the number of uplink power scans to measure uplink signal quality. Each time BTS accumulates the power scan values, value of this counter increment by one.

Measurement point

Accumulation occurs at point A3 in FIGURE 1

TRX Service Measurement TRX Service Measurement provides statistics of all the events relating TRX. It involves the measurement counters, which keeps the statistics such as:

Channel Activation

Page 66: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

50 Confidential and Proprietary Information of ZTE CORPORATION

Channel Deactivation

Handover Success

Handover Failure

Carrier Frequency interference band

Maximum and minimum uplink signal level

Maximum and minimum downlink signal level

Table 7 lists all TRX Service counters.

TRX Service Counters

TAB L E 7 T R X S E R V I C E C O U N T E R S

Counter No. Counter Definition

C00029 Number of intra-cell handover in attempts

C00030 Number of successful intra-cell handover ins

C00031 Number of Intra-BSC inter-cell handover in attempts

C00032 Number of successful Intra-BSC inter-cell handover ins

C00033 Number of Intra-MSC inter-cell handover in attempts

C00034 Number of successful Intra-MSC inter-cell handover ins

C00035 Total TCH busy time of

C00036 Total number of TCH seizures (including handover)

C00037 Total number of call drops due to TCH LAPD breakage

C00038 Number of call drops due to TCH wireless link failure

C00039 Total number of TCH handover call drops

C00040 Number of TCH/F activation attempts (including handover)

C00041 Number of successful TCH/F activations (including handover)

C00042 Number of TCH/F assignment attempts

C00043 Number of TCH/F assignment successes

C00044 Number of TCH/H activation attempts (including handover)

C00045 Number of successful TCH/H activations (including handover)

C00046 Number of TCH/H assignment attempts

C00047 Number of TCH/H assignment successes

C00048 Total SDCCH busy time

C00049 Total number of SDCCH call attempts

C00050 Total number of SDCCH call drops

C00051 Number of SDCCH activation attempts (including handover)

C00052 Number of SDCCH activation successes (including handover)

C00053 Number of SDCCH assignment attempts

C00054 Number of successful SDCCH assignments

Page 67: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 51

Counter No. Counter Definition

C00055 Number of samples with uplink RQ = 0

C00056 Number of samples with uplink RQ = 1

C00057 Number of samples with uplink RQ = 2

C00058 Number of samples with uplink RQ = 3

C00059 Number of samples with uplink RQ = 4

C00060 Number of samples with uplink RQ = 5

C00061 Number of samples with uplink RQ = 6

C00062 Number of samples with uplink RQ = 7

C00063 Number of samples with downlink RQ = 0

C00064 Number of samples with downlink RQ = 1

C00065 Number of samples with downlink RQ = 2

C00066 Number of samples with downlink RQ = 3

C00067 Number of samples with downlink RQ = 4

C00068 Number of samples with downlink RQ = 5

C00069 Number of samples with downlink RQ = 6

C00070 Number of samples with downlink RQ = 7

C00071 Mean number of idle TCH/Fs with interference band 0

C00072 Mean number of idle TCH/Fs with interference band 1

C00073 Mean number of idle TCH/Fs with interference band 2

C00074 Mean number of idle TCH/Fs with interference band 3

C00075 Mean number of idle TCH/Fs with interference band 4

C00076 Mean number of idle TCH/Fs with interference band 5

C00077 Mean number of idle TCH/Hs with interference band 0

C00078 Mean number of idle TCH/Hs with interference band 1

C00079 Mean number of idle TCH/Hs with interference band 2

C00080 Mean number of idle TCH/Hs with interference band 3

C00081 Mean number of idle TCH/Hs with interference band 4

C00082 Mean number of idle TCH/Hs with interference band 5

C00083 Mean number of idle SDCCHs with interference band 0

C00084 Mean number of idle SDCCHs with interference band 1

C00085 Mean number of idle SDCCHs with interference band 2

C00086 Mean number of idle SDCCHs with interference band 3

C00087 Mean number of idle SDCCHs with interference band 4

C00088 Mean number of idle SDCCHs with interference band 5

C00089 Maximum value obtained in regular scan of uplink signal level

C00090 Minimum value obtained in regular scan of uplink signal level

C00091 Maximum value obtained in regular scan of downlink signal level

Page 68: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

52 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C00092 Minimum value obtained in regular scan of downlink signal level

TRX Service Counters Explanation C00029 Definition

Number of intra-cell handover in attempts

Description

Intra-cell handover triggers due to receiving signal level, receiving quality level, interference and concentric cell. In intra-cell handover, source cell and target cell are same. During intra-cell handover, initially BSC sends CHANEL ACTIVATE message to destination channel. Then BTS sends CHANNEL ACTIVATE ACK message to BSC.

FIGURE 2 - I N T R A C E L L H AN D O V E R P R O C E S S

A1

BSCBTS:TRXMS

ASSIGNMENT COMMAND

CHANNEL ACTIVATE

A2

CHANNEL ACTIVATE ACK

ASSIGNMENT COMPLETE

Measurement Point

Counter starts when BSC receives Channel Activation Acknowledgment. Refer point A1 as shown in FIGURE 2.

C00030 Definition

Number of successful intra-cell handover-ins

Description

After successful activation of destination channel, BSC sends ASSIGNMENT COMMAND message to MS on source channel. When BSC

Page 69: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 53

receives ASSIGNMENT COMPLETE message from MS on destination channel, it indicates successful intra-cell handover.

Measurement Point

Refer point A2 as shown in FIGURE 2.

C00031 Definition

Number of Intra-BSC inter-cell handover in attempts

Description

In Intra-BSC inter-cell handover, source cell and target cell are different but lay under one BSC. During inter-cell handover, initially BSC sends CHANNEL ACTIVATE message to destination channel.

FIGURE 3 - I N T R A B S C H AN D O V E R P R O C E S S

A1

BSCOld BTS:MS

HANDOVER COMMAND

CHANNEL ACT

A2

CHANNEL ACT ACK

HANDOVER COMPLETE

New BTS

HANDOVER COMMAND

HANDOVER COMPLETE

Measurement Point

Refer point A1 as shown in FIGURE 3.

C00032 Definition

Number of successful Intra-BSC inter-cell handover-ins

Description

After successful activation of destination channel, BSC sends HANDOVER COMMAND message to MS on source channel. When BSC receives HANDOVER COMPLETE message from MS on destination channel, it indicates successful intra-BSC inter-cell handover.

Page 70: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

54 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Refer point A1 as shown in FIGURE 3.

C00033 Definition

Number of Intra-MSC inter-cell handover in attempts

Description

Intra-MSC inter-cell handover means handover initiation when BSC receives HANDOVER REQUEST message from MSC. Initially BSC receives HANDOVER REQUEST message form MSC. Then BSC sends CHANNEL ACTIVATE message to destination channel.

Measurement Point

After BSC receive CHANNEL ACTIVATE ACK message, value of this counter increments. Refer point A1 as shown in FIGURE 3.

C00034 Definition

Number of successful Intra-MSC inter-cell handover-ins

Description

After BSC successfully activates the destination channel, it receives HANDOVER COMPLETE message from MS, which indicates successful intra-MSC inter-cell handover.

Measurement Point

After successful handover, counter value increments. Refer point A2 as shown in FIGURE 3.

C00035 Definition

Total TCHs busy time

Description

It represents the total time for which MSs seizes the TCHs on TRX. TCHs comprise TCH/Fs and TCH/Hs. C00035 represents TRX traffic.

Measurement Point

Counter increments when:

MS seizes TCH successfully.

MS release TCH.

During timely measurement.

Page 71: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 55

Reported measurement value is accumulation of each measurement value. After each measurement, current time is set as last time for the next measurement. When MS seizes TCH successfully, number of seized TCHs increments by one. When MS releases TCH, number of seized TCHs decrements by one.

Measurement formula:

(Current time – time of last measurement) X (number of seized TCHs)

C00036 Definition

Total number of TCHs seizures (including handover)

Description

C00036 represents total number of TCH seizures on TRX. TCHs comprise both TCH/Fs and TCH/Hs.

Measurement Point

Counter increments upon successful TCHs seizures.

C00037 Definition

Total number of TCH LAPD call drops

Description

C00037 represents call drops due to LAPD link break.

Measurement Point

Counter increments when BSC receives LADP broken message.

C00038 Definition

Number of call drops due to TCH wireless link failure.

Description

C00038 represents call drops due to wireless link failure. Wireless link fails due to poor signal level and handover is not possible.

Measurement Point

Counter increments at reception of wireless link failure message.

C00039 Definition

Total number of TCH handover call drops

Page 72: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

56 Confidential and Proprietary Information of ZTE CORPORATION

Description

C0039 represents call drops due to handover failure. During intra-cell handover, if BSC does not receive ASSIGNMENT COMPLETE message in guard period, handover fails. During Intra-BSC handover, if BSC does not receive HANDOVER COMPLETE message in guard period, handover fails.

FIGURE 4 - I N T E R -C E L L H AN D O V E R F AI L U R E P R O C E S S

A1

BSCOld BTS:MS

HANDOVER COMMAND

CHANNEL ACT

A2

CHANNEL ACT ACK

New BTS

HANDOVER COMMANDSET T3103

T3103 Timeout

FIGURE 5 - I N T R A C E L L H AN D O V E R F AI L U R E P R O C E S S

A1

BSCBTS:TRXMS

ASSIGNMENT COMMAND

CHANNEL ACTIVATE

A2

CHANNEL ACTIVATE ACK

SET T3107

T3107 Timeout

Measurement Point

Counter increments when BSC receives T3103 or T3107 expiry message. Refer point A2 in FIGURE 4 and point A2 in FIGURE 5.

C00040 Definition

Number of TCH/F activation attempts (including handover)

Page 73: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 57

Description

C00040 represents number of TCH/Fs activation attempts on TRX, when CHANNEL ACTIVATE message is send.

Measurement Point

C00040 increments when BSC sends CHANNEL ACTIVATION message to BTS. Refer to FIGURE 1.

C00041 Definition

Number of successful TCH/F activations (including handover)

Description

C00041 represents number of successful TCH/F activations on TRX.

Measurement Point

C00041 increments when BSC receives CHANNEL ACTIVATE ACK message.

C00042 Definition

Number of TCH/F assignment attempts

Description

BSC sends an ASSIGNMENT COMMAND message to assign TCH/F.

Measurement Point

C00042 increments when BSC sends ASSIGNMENT COMMAND message to BTS.

C00043 Definition

Number of successful TCH/F assignments.

Description

BSC sends an ASSIGNMENT COMMAND message to assign TCH/F. After the BSC receives the EST IND or ASSIGNMENT COMPLETE message, indicates successful channel assignment.

Measurement Point

C00043 increments when BSC receives EST IND or ASSIGNMENT COMPLETE message.

Page 74: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

58 Confidential and Proprietary Information of ZTE CORPORATION

C00044 Definition

Number of TCH/H activation attempts (including handover)

Description

C00044 represents number of TCH/Hs activation attempts on TRX.

Measurement Point

C00044 increments when the BSC sends the CHANNEL ACTIVATE message to BTS.

C00045 Definition

Number of successful TCH/H activations (including handover)

Description

C00045 represents number of successful TCH/H activations on TRX.

Measurement Point

C00045 increments when BSC receives CHANNEL ACTIVATE ACK message.

C00046 Definition

Number of TCH/H assignment attempts

Description

BSC sends an ASSIGNMENT COMMAND message to assign TCH/H.

Measurement Point

C00046 increments when BSC sends ASSIGNMENT COMMAND message to BTS.

C00047 Definition

Number of successful TCH/H assignments

Description

BSC sends an ASSIGNMENT COMMAND message to assign a TCH/H. After BSC receives EST IND or ASSIGNMENT COMPLETE message, indicates successful TCH/H assignment.

Measurement Point

Page 75: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 59

C00047 increments when BSC receives EST IND or ASSIGNMENT COMPLETE message.

C00048 Definition

Total SDCCHs busy time

Description

C00048 represents total time of SDCCHs seizures on TRX. It includes both assignment and handover. C00048 shows traffic of SDCCHs on TRX.

Measurement Point

C00048 increments when:

MS seizes SDCCH successfully.

MS releases SDCCH.

During timely measurement.

Reported measurement value is accumulation of each measurement value. After each measurement, current time is set as last time for the next measurement. When MS seizes SDCCH successfully, number of seized SDCCH increments by one. When MS releases SDCCH, number of seized SDCCH decrements by one.

Measurement formula:

(Current time – time of last measurement) X (Number of seized SDCCHs)

C00049 Definition

Total number of SDCCH call attempts

Description

Total number of SDCCH call attempts = Number of successful SDCCH seizers + Number of unsuccessful SDCCH seizers

Measurement Point

C00049 increments for each successful or unsuccessful SDCCH seizer

C00050 Definition

Total number of SDCCH call drops

Description

SDCCH call drops due to following causes:

Page 76: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

60 Confidential and Proprietary Information of ZTE CORPORATION

T3103 expires in case of inter-cell handover (FIGURE 4)

T3107 expires in case of intra-cell handover (FIGURE 5)

T8 expires in case of external handover (FIGURE 6)

FIGURE 6 - T8 T I M E O U T

A1

BSCOld BTS:MS

HANDOVER COMMAND

CHANNEL ACT

A2

CHANNEL ACT ACK

New BTS

HANDOVER COMMANDSET T3103

T3103 Timeout

C00050 increments when:

BSC receives LAPD link break message on SDCCH.

BSC receives connection failure message and the channel is an SDCCH.

T8 expires.

T3103 expires.

T3107 expires.

C00051 Definition

Number of SDCCH activation attempts (including handover)

Description

C00051 represents number of SDCCHs activation attempts on TRX when CHANNEL ACTIVATE message is send.

Measurement Point

Counter increments when BSC sends CHANNEL ACTIVATE message to BTS.

C00052 Definition

Number of successful SDCCH activations (including handover)

Page 77: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 61

Definition

C00052 represents number of successful SDCCH activations on TRX.

Measurement Point

C00052 increments when BSC receives CHANNEL ACTIVATE ACK message.

C00053 Definition

Number of SDCCH assignment attempts

Description

BSC sends an IMMEDIATE ASSIGNMENT or ASSIGNMENT COMMAND message to assign an SDCCH.

Measurement Point

C00053 increments when BSC sends IMMEDIATE ASSIGNMENT or ASSIGNMENT COMMAND message to BTS.

C00054 Definition

Number of successful SDCCH assignments

Description

BSC sends an IMMEDIATE ASSIGNMENT or ASSIGNMENT COMMAND message to assign an SDCCH. After BSC receives EST IND (CM SERV REQ) or ASSIGNMENT COMPLETE message, indicates successful channel assignment.

Measurement Point

C00054 increments when BSC receives EST IND (CM SERV REQ) or ASSIGNMENT COMPLETE message.

C00055 Definition

Number of samples with uplink RQ = 0

Description

BTS measures level, quality and interference of uplink signals through measurement report from MS. BTS sends measurement report to BSC after every multi frame (480ms). The measurement value is the number of samples with uplink RQ = 0 in the measurement report.

Measurement Point

C00055 increments when BSC receives uplink samples with RQ=0

Page 78: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

62 Confidential and Proprietary Information of ZTE CORPORATION

C00056 Definition

Number of samples with uplink RQ = 1

Description

C00056 represents number of samples with uplink RQ = 1 in measurement report.

Measurement Point

C00056 increments when BSC receives uplink samples with RQ=1

C00057 Definition

Number of samples with uplink RQ = 2

Description

C00057 represents number of samples with uplink RQ = 2 in measurement report.

Measurement Point

C00057 increments when BSC receives uplink samples with RQ=2

C00058 Definition

Number of samples with uplink RQ = 3

Description

C00058 represents number of samples with uplink RQ = 3 in measurement report.

Measurement Point

C00058 increments when BSC receives uplink samples with RQ=3

C00059 Definition

Number of samples with uplink RQ = 4

Description

C00059 represents number of samples with uplink RQ = 4 in measurement report.

Measurement Point

C00059 increments when BSC receives uplink samples with RQ=4

Page 79: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 63

C00060 Definition

Number of samples with uplink RQ = 5

Description

C00060 represents number of samples with uplink RQ = 5 in measurement report.

Measurement Point

C00060 increments when BSC receives uplink samples with RQ=5

C00061 Definition

Number of samples with uplink RQ = 6

Description

C00061 represents number of samples with uplink RQ = 6 in measurement report.

Measurement Point

C00061 increments when BSC receives uplink samples with RQ=6

C00062 Definition

Number of samples with uplink RQ = 7

Definition

C00062 represents number of samples with uplink RQ = 7 in measurement report.

Measurement Point

C00062 increments when BSC receives uplink samples with RQ=7

C00063 Definition

Number of samples with downlink RQ = 0

Description

C00063 represents number of samples with downlink RQ = 0 in measurement report.

Measurement Point

C00063 increments when BSC receives downlink samples with RQ=0

Page 80: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

64 Confidential and Proprietary Information of ZTE CORPORATION

C00064 Definition

Number of samples with downlink RQ = 1

Description

C00064 represents number of samples with downlink RQ = 1 in measurement report.

Measurement Point

C00064 increments when BSC receives downlink samples with RQ=1

C00065 Definition

Number of samples with downlink RQ = 2

Description

C00065 represents number of samples with downlink RQ = 2 in measurement report.

Measurement Point

C00065 increments when BSC receives downlink samples with RQ=2

C00066 Definition

Number of samples with downlink RQ = 3

Definition

C00066 represents number of samples with downlink RQ = 3 in measurement report.

Measurement Point

C00066 increments when BSC receives downlink samples with RQ=3

C00067 Definition

Number of samples with downlink RQ = 4

Definition

C00067 represents number of samples with downlink RQ = 4 in measurement report.

Measurement Point

C00067 increments when BSC receives downlink samples with RQ=4

Page 81: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 65

C00068 Definition

Number of samples with downlink RQ = 5

Description

C00068 represents number of samples with downlink RQ = 5 in measurement report.

Measurement Point

C00068 increments when BSC receives downlink samples with RQ=5

C00069 Definition

Number of samples with downlink RQ = 6

Description

C00069 represents number of samples with downlink RQ = 6 in measurement report.

Measurement Point

C00068 increments when BSC receives downlink samples with RQ=6

C00070 Definition

Number of samples with downlink RQ = 7

Description

C00070 represents number of samples with downlink RQ = 7 in measurement report.

Measurement Point

C00070 increments when BSC receives downlink samples with RQ=7

C00071 Definition

Mean number of idle TCH/Fs with interference band 0

Description

System regularly queries database to obtain Mean number of idle TCH/Fs and various interference levels on TRX. System uses querying point value to represent average value. System updates interference band levels of TCH/Fs after BSC receives wireless resource indication message from BTS. Measurement mechanisms of counters C00072 to

Page 82: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

66 Confidential and Proprietary Information of ZTE CORPORATION

C00088 is same as this counter. C00071 represents the Mean number of idle TCH/Fs on TRX with interference band 0.

Measurement Point

Counter increments when database is queried regularly.

C00072 Definition

Mean number of idle TCH/Fs with interference band 1

Description

C00072 represents the mean number of idle TCH/Fs on TRX with interference band 1.

Measurement Point

Counter increments when database is queried regularly.

C00073 Definition

Mean number of idle TCH/Fs with interference band 2

Description

C00073 represents the mean number of idle TCH/Fs on TRX with interference band 2.

Measurement Point

Counter increments when database is queried regularly.

C00074 Definition

Mean number of idle TCH/Fs with interference band 3

Description

C00074 represents the mean number of idle TCH/Fs on TRX with interference band 3.

Measurement Point

Counter increments when database is queried regularly.

C00075 Definition

Mean number of idle TCH/Fs with interference band

Description

Page 83: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 67

C00075 represents the mean number of idle TCH/Fs on TRX with interference band 4.

Measurement Point

Counter increments when database is queried regularly.

C00076 Definition

Mean number of idle TCH/Fs with interference band 5

Description

C00076 represents the mean number of idle TCH/Fs on TRX with interference band 5.

Measurement Point

Counter increments when database is queried regularly.

C00077 Definition

Mean number of idle TCH/Hs with interference band 0

Description

C00077 represents the mean number of idle TCH/Hs on TRX with interference band 0.

Measurement Point

Counter increments when database is queried regularly.

C00078 Definition

Mean number of idle TCH/Hs with interference band 1

Description

C00078 represents the mean number of idle TCH/Hs on TRX with interference band1.

Measurement Point

Counter increments when database is queried regularly.

C00079 Definition

Mean number of idle TCH/Hs with interference band 2

Description

Page 84: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

68 Confidential and Proprietary Information of ZTE CORPORATION

C00079 represents the mean number of idle TCH/Hs on TRX with interference band 2.

Measurement Point

Counter increments when database is queried regularly.

C00080 Definition

Mean number of idle TCH/Hs with interference band 3

Description

C00080 represents the mean number of idle TCH/Hs on TRX with interference band 3.

Measurement Point

Counter increments when database is queried regularly.

C00081 Definition

Mean number of idle TCH/Hs with interference band 4

Description

C00081 represents the number of idle TCH/Hs on TRX with interference band4.

Measurement Point

Counter increments when database is queried regularly.

C00082 Definition

Mean number of idle TCH/Hs with interference band 5

Description

C00082 represents the Mean number of idle TCH/Hs on TRX with interference band 5.

Measurement Point

Counter increments when database is queried regularly.

C00083 Definition

Mean number of idle SDCCHs with interference band 0

Description

Page 85: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 69

C00083 represents the Mean number of idle SDCCHs on TRX with interference band 0

Measurement Point

Counter increments when database is queried regularly.

C00084 Definition

Mean number of idle SDCCHs with interference band 1

Description

C00084 represents the Mean number of idle SDCCHs on TRX with interference band 1.

Measurement Point

Counter increments when database is queried regularly.

C00085 Definition

Mean number of idle SDCCHs with interference band 2

Description

C00085 represents the Mean number of idle SDCCHs on TRX with interference band two.

Measurement Point

Counter increments when database is queried regularly.

C00086 Definition

Mean number of idle SDCCHs with interference band 3

Description

C00086 represents the Mean number of idle SDCCHs on TRX with interference band three.

Measurement Point

Counter increments when database is queried regularly.

C00087 Definition

Mean number of idle SDCCHs with interference band 4

Description

Page 86: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

70 Confidential and Proprietary Information of ZTE CORPORATION

C00087 represents the number of idle SDCCHs on TRX with interference band four.

Measurement Point

Counter increments when the database is queried regularly.

C00088 Definition

Mean number of idle SDCCHs with interference band 5

Description

C00088 represents the number of idle SDCCHs on TRX with interference band 5.

Measurement Point

Counter increments when database is queried regularly.

C00089 Definition

Maximum value obtained in regular scan of uplink signal level

Description

C00089 represents maximum uplink signal value that BSC receives among all the sample values for power control.

Measurement Point

Counter increments when BSC receives PC TEST RPT message.

C00090 Definition

Minimum value obtained in regular scan of uplink signal level

Description

C00090 represents minimum uplink signal value that BSC receives among all the sample values for power control.

Measurement Point

Counter increments when BSC receives PC TEST RPT message.

C00091 Definition

Maximum value obtained in regular scan of downlink signal level

Description

Page 87: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 71

C00091 represents maximum downlink signal value that BSC receives among all the sample values for power control.

Measurement Point

Counter increments when BSC receives PC TEST RPT message.

C00092 Definition

Minimum value obtained in regular scan of downlink signal level

Description

C00092 represents maximum downlink signal value that BSC receives among all the sample values for power control.

Measurement Point

Counter increments when BSC receives PC TEST RPT message.

Paging Messages Measurement Paging messages measurement provides statistics of discard Circuit Switched (CS) and Packet Switched (PS) paging messages due to full queue length. Measurement unit is TRX.

Paging Messages Measurement Counters Table 8 lists all paging messages measurement counters.

TAB L E 8 P AG I N G M E AS U R E M E N T C O U N T E R S

Counter No. Counter Definition

C01001 Number of PS paging message discarded because the queue is full

C01002 Number of CS paging message discarded because the queue is full

C01003 Average length of CH queue: 9 x 9

C01004 Average length of PCH queue: 9 x 64

TRX Basic Measurement TRX basic measurement provides statistics of time slot seizures in TRX. TRX Basic Measurement Counters provides information such as time duration and number of TCH and SDCCH seizures.

Page 88: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

72 Confidential and Proprietary Information of ZTE CORPORATION

TRX Basic Measurement Counters

TAB L E 9 C O U N T E R S O F C AR R I E R FR E Q U E N C Y -LE V E L B AS I C M E AS U R E M E N T

Counter No. Counter Definition

C13001 Seizure duration of TCHs

C13002 Number of TCH seizure

C13003 Seizure duration of SDCCHs

C13004 Number of SDCCH seizure

TRX Power &Temperature Measurement TRX temperature and TRX power is measured on TRU and reported to BSC periodically.

TRX Power & Temperature Measurement Counters Table 10 lists all the TRX Temperature and Power measurement counters.

TAB L E 10 TRX P O W E R AN D TE M P E R AT U R E C O U N T E R S

Counter Name Counter Definition

C14001 Maximum TRX power value

C14002 Minimum TRX power value

C14003 Mean TRX power value

C14004 Maximum TRX temperature value

C14005 Minimum TRX temperature value

C14006 Mean TRX temperature value

TRX Power & Temperature Measurement Counters Explanation C14001 Definition

Maximum TRX power value

Description

Page 89: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 2 - BTS Measurement

Confidential and Proprietary Information of ZTE CORPORATION 73

C14001 represents the maximum value of TRX power within the measurement period. Measurement unit is dbm

Measurement Point

System collects the measurement from TRU.

C14002 Definition

Minimum value of TRX power

Description

C14002 represents the minimum value of TRX power within the measurement period. Measurement unit is dbm.

Measurement Point

System collects the measurement from TRU.

C14003 Definition

Mean TRX power value

Description

It represents the mean value of TRX power within the measurement period. Measurement unit is dbm.

Measurement Point

System collects the measurement from TRU.

C14004 Definition

Maximum TRX temperature value

Description

C14004 represents the maximum value of TRX temperature within the measurement period. Measurement unit is Celsius.

Measurement Point

System collects the measurement from TRU.

C14005 Definition

Minimum TRX temperature value

Description

Page 90: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

74 Confidential and Proprietary Information of ZTE CORPORATION

C14005 represents the minimum value of TRX temperature within the measurement period. Measurement unit is Celsius.

Measurement Point

System collects the measurement from TRU.

C14006 Definition

Mean TRX temperature value

Description

C14006 represents the mean value of TRX temperature within the measurement period. Measurement unit is Celsius

Measurement Point

System collects the measurement from TRU.

Page 91: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 75

C h a p t e r 3

Wireless Channels

This chapter covers the following topics:

Channels Measurement

Channels Measurement Channel Measurement here means wireless channel measurement in a cell, as mobile communication is always through wireless medium. It refers to the measurement of channel properties, which directly affects the Quality of Service (QoS) in wireless communication, in a particular cell. Channel properties such as received level, received quality, Timing Advance (TA) and interference of both uplink and downlink signals. These measurements are for the channels in busy or idle modes.

BTS sends MS measurement report to BSC every 480ms. BSC measures uplink and downlink signal, TA and RQ value in a channel. BSC updates interference band in database when it receives measurement report from BTS.

Channels Counters Table 11 lists all the Channel Measurement Counters.

TAB L E 11 C H AN N E L M E AS U R E M E N T C O U N T E R S

Counter No. Counter Definition

C10701 Number of uplink signal quality samples in wireless channels

C10702 Level of worst uplink signal quality in wireless channels

C10703 Total value of uplink quality level values in wireless channels

C10704 Number of downlink signal quality samples in wireless channels

C10705 Level of worst downlink signal quality in wireless channels

C10706 Total value of downlink quality strength values in wireless channels

Page 92: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

76 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C10707 Number of received uplink signal strength samples in wireless channels

C10708 Maximum received uplink signal strength in wireless channels

C10709 Minimum received uplink signal strength in wireless channels

C10710 Total value of uplink signal strength in wireless channels

C10711 Number of received downlink signal strength samples in wireless channels

C10712 Maximum received downlink signal strength in wireless channels

C10713 Minimum downlink received signal strength in wireless channels

C10714 Total value of downlink signal strength in wireless channels

C10715 Number of TA samples in wireless channels

C10716 Maximum TA in wireless channels

C10717 Total number of TAs in wireless channels

C10718 Mean number of idle TCH/Fs with interference band 0

C10719 Mean number of idle TCH/Fs with interference band 1

C10720 Mean number of idle TCH/Fs with interference band 2

C10721 Mean number of idle TCH/Fs with interference band 3

C10722 Mean number of idle TCH/Fs with interference band 4

C10723 Mean number of idle TCH/Fs with interference band 5

C10724 Mean number of idle TCH/Hs with interference band 0

C10725 Mean number of idle TCH/Hs with interference band 1

C10726 Mean number of idle TCH/Hs with interference band 2

C10727 Mean number of idle TCH/Hs with interference band 3

C10728 Mean number of idle TCH/Hs with interference band 4

C10729 Mean number of idle TCH/Hs with interference band 5

C10730 Mean number of idle SDCCHs with interference band 0

C10731 Mean number of idle SDCCHs with interference band 1

C10732 Mean number of idle SDCCHs with interference band 2

C10733 Mean number of idle SDCCHs with interference band 3

C10734 Mean number of idle SDCCHs with interference band 4

C10735 Mean number of idle SDCCHs with interference band 5

C10736 Number of samples with uplink RQ = 0

C10737 Number of samples with uplink RQ = 1

C10738 Number of samples with uplink RQ = 2

C10739 Number of samples with uplink RQ = 3

C10740 Number of samples with uplink RQ = 4

C10741 Number of samples with uplink RQ = 5

C10742 Number of samples with uplink RQ = 6

Page 93: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 3 - Wireless Channels

Confidential and Proprietary Information of ZTE CORPORATION 77

Counter No. Counter Definition

C10743 Number of samples with uplink RQ = 7

C10744 Number of samples with downlink RQ = 0

C10745 Number of samples with downlink RQ = 1

C10746 Number of samples with downlink RQ = 2

C10747 Number of samples with downlink RQ = 3

C10748 Number of samples with downlink RQ = 4

C10749 Number of samples with downlink RQ = 5

C10750 Number of samples with downlink RQ = 6

C10751 Number of samples with downlink RQ = 7

Channels Counters Explanation C10701 Definition

Number of uplink signal quality samples in wireless channels

Description

BTS sends measurement report of MS to BSC. BSC upon receiving the measurement report does pre-processing. C10701 represents number of uplink signal quality samples that BSC receives in measurement report.

Measurement Point

C10701 increments when BSC receives the samples or preprocesses the measurement report.

C10702 Definition

Level of worst uplink signal quality in wireless channels

Description

BTS sends measurement report of MS to BSC. BSC upon receiving the measurement report does pre-processing. If uplink signal quality level of wireless channels is lower than the lowest uplink quality level recoded previously, this counter stores the new lowest value.

Measurement Point

C10702 increments when BSC receives the samples or preprocesses the measurement report.

Page 94: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

78 Confidential and Proprietary Information of ZTE CORPORATION

C10703 Definition

Total value of uplink quality values in wireless channels

Description

C10703 accumulates uplink quality level values that BSC receives in measurement report and represents the total value.

Measurement Point

C10703 increments when BSC receives the values or preprocesses the measurement report.

C10704 Definition

Number of downlink signal quality samples in wireless channels

Description

BTS sends measurement report of MS to BSC. BSC upon receiving the measurement report does pre-processing. C10704 represents number of downlink signal quality samples that BSC receives in measurement report.

Measurement Point

C10704 increments when BSC receives the samples or preprocesses the measurement report.

C10705 Definition

Level of worst downlink signal quality in wireless channels

Description

BTS sends measurement report of MS to BSC. BSC upon receiving the measurement report does pre-processing. If downlink signal quality level of wireless channels is lower than the lowest downlink quality level recoded previously, this counter stores the new lowest value.

Measurement Point

C10705 increments when BSC receives the samples or preprocesses the measurement report.

C10706 Definition

Total value of downlink signal quality values in wireless channels

Page 95: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 3 - Wireless Channels

Confidential and Proprietary Information of ZTE CORPORATION 79

Description

C10706 accumulates downlink quality level values that BSC receives in measurement report and represents total value.

Measurement Point

C10706 increments when BSC receives the values or preprocesses the measurement report.

C10707 Definition

Number of received uplink signal strength samples in wireless channels

Description

BTS sends measurement report of MS to BSC. BSC upon receiving the measurement report does pre-processing. C10707 represents number of uplink signal strength samples that BSC receives in measurement report.

Measurement Point

C10707 increments when BSC receives the samples or preprocesses the measurement report.

C10708 Definition

Maximum received uplink signal strength in wireless channels

Description

If received uplink signal strength is higher than the previously record maximum uplink signal strength, then this counter stores the new value.

Measurement Point

C10708 increments when BSC receives the samples or preprocesses the measurement report.

C10709 Definition

Minimum received uplink signal strength in wireless channels

Description

If received uplink signal level is lower than the previously record maximum uplink signal level, then this counter stores the new value.

Page 96: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

80 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C10709 increments when BSC receives the samples or preprocesses the measurement report.

C10710 Definition

Total value of uplink signal strength in wireless channels

Definition

C10710 accumulates the uplink receiving strength values that BSC receives in the measurement report from MS and represents the total value.

Measurement Point

C10710 increments when BSC receives the values or preprocesses the measurement report.

C10711 Definition

Number of received downlink signal strength samples in wireless channels

Description

BTS sends measurement report of MS to BSC. BSC upon receiving the measurement report does pre-processing. C10711 represents number of downlink signal strength samples that BSC receives in measurement report.

Measurement Point

C10711 increments when BSC receives the values or preprocesses the measurement report.

C10712 Definition

Maximum received downlink signal strength in wireless channels

Description

If received downlink signal strength is higher than the previously record maximum downlink signal strength, then this counter stores the new value.

Measurement Point

C10712 increments when BSC receives the values or preprocesses the measurement report.

Page 97: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 3 - Wireless Channels

Confidential and Proprietary Information of ZTE CORPORATION 81

C10713 Definition

Minimum received downlink signal strength in wireless channels

Description

If received downlink signal strength is lower than the previously record minimum downlink signal strength, then this counter stores the new value.

Measurement Point

C10713 increments when BSC receives the values or preprocesses the measurement report.

C10714 Definition

Total value of downlink signal strength in wireless channels

Description

C10714 accumulates the downlink receiving strength values that BSC receives in the measurement report from MS and represents the total value.

Measurement Point

C10714 increments when BSC receives the values or preprocesses the measurement report.

C10715 Definition

Number of TA samples in wireless channels

Description

C10715 represents total number of TA samples that BSC receives in the measurement report of MS.

Measurement Point

C10715 increments when BSC receives the values or preprocesses the measurement report.

C10716 Definition

Maximum TA in wireless channels

Page 98: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

82 Confidential and Proprietary Information of ZTE CORPORATION

Description

If TA in the measurement report is greater than the maximum TA in the previous record, this counter stores the new value.

Measurement Point

C10716 increments when BSC receives the values or preprocesses the measurement report.

C10717 Definition

Total number of TAs in wireless channels

Description

C10717 accumulates TA in measurement report and obtains total TA in wireless channels.

Measurement Point

C10717 increments when BSC receives the values or preprocesses the measurement report.

For counters C10718~C10751, refer to TRX Service Counters Explanation.

C10718 Definition

Mean number of idle TCH/Fs with interference band 0

C10719 Definition

Mean number of idle TCH/Fs with interference band 1

C10720 Definition

Mean number of idle TCH/Fs with interference band 2

C10721 Definition

Mean number of idle TCH/Fs with interference band 3

C10722 Description

Page 99: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 3 - Wireless Channels

Confidential and Proprietary Information of ZTE CORPORATION 83

Mean number of idle TCH/Fs with interference band 4

C10723 Definition

Mean number of idle TCH/Fs with interference band 5

C10724 Definition

Mean number of idle TCH/Hs with interference band 0

C10725 Definition

Mean number of idle TCH/Hs with interference band 1

C10726 Definition

Mean number of idle TCH/Hs with interference band 2

C10727 Definition

Mean number of idle TCH/Hs with interference band 3

C10728 Definition

Mean number of idle TCH/Hs with interference band 4

C10729 Definition

Mean number of idle TCH/Hs with interference band 5

C10730 Definition

Mean number of idle SDCCHs with interference band 0

Page 100: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

84 Confidential and Proprietary Information of ZTE CORPORATION

C10730 Definition

Mean number of idle SDCCHs with interference band 0

C10731 Definition

Mean number of idle SDCCHs with interference band 1

C10732 Definition

Mean number of idle SDCCHs with interference band 2

C10733 Definition

Mean number of idle SDCCHs with interference band 3

C10734 Definition

Mean number of idle SDCCHs with interference band 4

C10735 Definition

Mean number of idle SDCCHs with interference band 5

C10736 Definition

Number of samples with uplink RQ = 0

C10737 Definition

Number of samples with uplink RQ = 1

C10738 Definition

Number of samples with uplink RQ = 2

Page 101: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 3 - Wireless Channels

Confidential and Proprietary Information of ZTE CORPORATION 85

C10739 Definition

Number of samples with uplink RQ = 3

C10740 Definition

Number of samples with uplink RQ = 4

C10741 Definition

Number of samples with uplink RQ = 5

C10742 Definition

Number of samples with uplink RQ = 6

C10743 Definition

Number of samples with uplink RQ = 7

C10744 Definition

Number of samples with downlink RQ = 0

C10745 Definition

Number of samples with downlink RQ = 1

C10746 Definition

Number of samples with downlink RQ = 2

C10747 Description

Number of samples with downlink RQ = 3

Page 102: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

86 Confidential and Proprietary Information of ZTE CORPORATION

C10748 Definition

Number of samples with downlink RQ = 4

C10749 Definition

Number of samples with downlink RQ = 5

C10750 Definition

Number of samples with downlink RQ = 6

C10751 Definition

Number of samples with downlink RQ = 7

Page 103: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 87

C h a p t e r 4

Random Access

This chapter covers the following topics:

Random Access Measurement

Random Access Measurement Random access measurement provides statistics such as number of:

Random access attempts

Random access processes

Successful random accesses

For random access slot-aloha is used as an access protocol. Single access may have multiple random access requests.

Random access success ratio means of number of successful random accesses divided by successful random access requests. This ratio reflects the channel blocking status.

Collision may occur between numbers of random access requests, for which time interval adjustment is required.

FIGURE 5 illustrates the Random Access Process.

Random Access Counters Table 12 lists all the random access counters.

TAB L E 12 R AN D O M AC C E S S C O U N T E R S

Counter No. Counter Definition

C10001 Number of invalid access requests

C10002 Number of Mobile Originated Call (MOC) random access attempts

C10003 Number of successful random access processes due to MOC

Page 104: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

88 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

attempts

C10004 Number of successful random accesses due to MOC

C10005 Number of Mobile Terminated Call (MTC) random access attempts

C10006 Number of successful random access processes due to MTC attempts

C10007 Number of successful random accesses due to MTC

C10008 Number of random access attempts due to call re-establishment.

C10009 Number of successful random access processes due to call re-establishment

C10010 Number of successful random accesses due to call re-establishment

C10011 Number of random access attempts due to emergency calls

C10012 Number of successful random access processes due to emergency calls

C10013 Number of successful random accesses due to emergency calls

C10014 Number of random access attempts due to LOC

C10015 Number of successful random access processes due LOC

C10016 Number of successful random accesses due to LOC

C10017 Number of random access attempts for other causes

C10018 Number of successful random access processes for other causes

C10019 Number of successful random accesses for other causes

C10020 Number of wireless channel accesses due to location update

C10021 Number of wireless channel accesses due to call originations

C10022 Number of wireless channel accesses due to paging responses

C10023 Number of wireless channel accesses due to call re-establishments

C10024 Number o number of wireless channel accesses due to IMSI detachment

C10025 Number of wireless channel accesses due to other causes

Random Access Counters Explanation C10001 Definition

Number of invalid random access requests

Description

C10001 represents number of invalid requests for channel. Initially MS sends Channel request to BTS for random access. Then BTS sends Channel required message to BSC in response of MS request. If TA

Page 105: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 4 - Random Access

Confidential and Proprietary Information of ZTE CORPORATION 89

exceeds cell range, BSC treats this access request as interference. At this time, BSC discards invalid channel request and C10001 increments.

Measurement Point

Refer point A2 as shown in FIGURE 7.

FIGURE 7 - R AN D O M AC C E S S P R O C E S S

M S B T S B S C

C H L _ R E Q

C H L _ R Q D

A 1

A 2C H L _ A C T

C H L _ A C T _ A C K

A 3

I M M _ A S S _ C M D

I M M _ A S S

S A B M

E S T _ I N D

A 4

C10002 Definition

Number of Mobile Originated Call (MOC) random access attempts

Description

C10002 represents number of random access requests due to Mobile Originated Call (MOC). If TA does not exceed cell range, BSC treats this random access request as valid mobile originated call and C10003 increments.

Measurement Point

Refer point A1 as shown in FIGURE 7.

C10003 Definition

Number of successful random access processes due to MOC attempts

Description

BSC allows MS to access the network due to MOC. Initially MS sends CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT command to BTS to activate the channel for MS. BTS in response sends CHL_ACT_ACK message to BSC. After that, C10003 increments and BSC sends IMM_ASS_CMD message to BTS and then to MS.

Measurement Point

Page 106: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

90 Confidential and Proprietary Information of ZTE CORPORATION

Refer point A3 in FIGURE 7.

C10004 Definition

Number of successful MOC random accesses

Description

C10004 represents number of successful random accesses, when BTS assigns the channel to MS due to mobile originated call (MOC). After successfully access, MS sends EST_IND message to BSC through BTS. C10004 increments when BSC receives EST_IND message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10005 Definition

Number of Mobile Terminated Call (MTC) random access attempts

Description

C10005 represents number of random access requests due to MTC. If TA does not exceed cell range, BSC treats this random access request as valid mobile Terminated call and C10003 increments.

Measurement Point

Refer point A1 as shown in FIGURE 7.

C10006 Definition

Number of successful random access processes due to MTC attempts

Description

BSC allows MS to access the network due to MTC. Initially MS sends CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT command to BTS to activate the channel for MS. BTS in response sends CHL_ACT_ACK message to BSC. After that, C10003 increments and BSC sends IMM_ASS_CMD message to BTS and then to MS.

Measurement Point

Refer point A3 as shown in FIGURE 7.

C10007 Definition

Number of successful MTC random accesses

Page 107: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 4 - Random Access

Confidential and Proprietary Information of ZTE CORPORATION 91

Description

C10007 represents number of successful random accesses, when BTS assigns the channel to MS due to MTC. After successfully access, MS sends EST_IND message to BSC through BTS. C10007 increments when BSC receives EST_IND message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10008 Definition

Number of random access attempts due to call re-establishment.

Description

C10008 represents number of random access requests due to call re-establishment. Initially MS sends CHL_REQ message to BTS to apply for channel. Then BTS sends CHL_RQD message to BSC in response of MS request. C10003 increments, if TA does not exceed cell range and cause of wireless access is call reestablishment.

Measurement Point

Refer point A1 as shown in FIGURE 7.

C10009 Definition

Number of successful random access processes due to call re-establishment

Description

BSC allows MS to access the network due to MTC. Initially MS sends CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT command to BTS to activate the channel for MS. BTS in response sends CHL_ACT_ACK message to BSC. After that, C10009 increments and BSC sends IMM_ASS_CMD message to BTS and then to MS.

Measurement Point

Refer point A3 as shown in FIGURE 7.

C10010 Definition

Number of successful random accesses due to call re-establishment

Description

C10010 represents number of successful random accesses, when BTS assigns the channel to MS due for call-reestablishment. After

Page 108: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

92 Confidential and Proprietary Information of ZTE CORPORATION

successfully access, MS sends EST_IND message to BSC through BTS. C10010 increments when BSC receives EST_IND message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10011 Definition

Number of random access attempts due to emergency calls

Description

C10011 represents number of random access requests due to emergency calls. Initially MS sends CHL_REQ message to BTS to apply for channel. Then BTS sends CHL_RQD message to BSC in response of MS request. If TA does not exceed cell range and cause of wireless access is call reestablishment, C10011 increments.

Measurement Point

Refer point A1 as shown in FIGURE 7.

C10012 Definition

Number of successful random access processes due to emergency calls

Description

BSC allows MS to access the network due to emergency calls. Initially MS sends CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT command to BTS to activate the channel for MS. BTS in response sends CHL_ACT_ACK message to BSC. After that, C10012 increments and BSC sends IMM_ASS_CMD message to BTS and then to MS.

Measurement Point

Refer point A3 as shown in FIGURE 7.

C10013 Definition

Number of successful random accesses due to emergency calls

Description

C10013 represents number of successful random accesses, when BTS assigns the channel to MS due for emergency calls. After successfully access, MS sends EST_IND message to BSC through BTS. C10013 increments when BSC receives EST_IND message.

Page 109: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 4 - Random Access

Confidential and Proprietary Information of ZTE CORPORATION 93

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10014 Definition

Number of wireless access attempts due to location update request

Description

C10014 represents number of accesses to wireless channel requests due to location update request. Initially MS sends CHL_REQ message to BTS to apply for a wireless channel. Then BTS sends CHL_RQD message to BSC as a response of MS request. If TA does not exceed cell range and cause of random access is location update, C10014 increments.

Measurement Point

Refer point A1 as shown in FIGURE 7.

C10015 Definition

Number of successful random access processes due to location update

Description

BSC allows MS to access the network due to location update. Initially MS sends CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT command to BTS to activate the channel for MS. BTS in response sends CHL_ACT_ACK message to BSC. After that, C10015 increments and BSC sends IMM_ASS_CMD message to BTS and then to MS.

Measurement Point

Refer point A3 as shown in FIGURE 7.

C10016 Definition

Number of successful random accesses due to location update

Description

C10016 represents number of successful random accesses, when BTS assigns the channel to MS due for location update. After successfully access, MS sends EST_IND message to BSC through BTS. C10016 increments when BSC receives EST_IND message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

Page 110: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

94 Confidential and Proprietary Information of ZTE CORPORATION

C10017 Definition

Number of random access attempts for other causes

Description

C10017 represents number of random access requests for causes other than MOC, MTC, call re-establishment, LOC, emergency call or IMSI detachment. Initially MS sends CHL_REQ message to BTS to apply for a channel. Then BTS sends CHL_RQD message to BSC in response of MS request. If TA does not exceed cell range and cause of random access is other than the above mention causes C10017 increments.

Measurement Point

Refer point A1 as shown in FIGURE 7.

C10018 Definition

Number of successful random access processes for other causes

Description

BSC allows MS to access the network for other causes. Initially MS sends CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT command to BTS to activate the channel for MS. BTS in response sends CHL_ACT_ACK message to BSC. After that, C10018 increments and BSC sends IMM_ASS_CMD message to BTS and then to MS.

Measurement Point

Refer point A3 as shown in FIGURE 7.

C10019 Definition

Number of successful random accesses for other causes

Description

C10019 represents number of successful random accesses, when BTS assigns the channel to MS for other causes. After successfully access, MS sends EST_IND message to BSC through BTS. C10019 increments when BSC receives EST_IND message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

Page 111: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 4 - Random Access

Confidential and Proprietary Information of ZTE CORPORATION 95

C10020 Definition

Number of wireless accesses due to is location update

Description

C10020 represents number of wireless accesses due to location update. Counter C10020 increments when BSC receives EST_IND message and access cause is location update in L3 message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10021 Definition

Number of wireless channel accesses due to call origination

Description

C10021 represents number of wireless channel accesses due to call origination. C10021 increments when BSC receives EST_IND message and access cause is call origination in L3 message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10022 Definition

Number of wireless channel accesses due to paging response

Description

C10022 represents number of wireless channel accesses due to paging response. Counter C10022 increments when BSC receives EST_IND message and access cause is paging response in L3 message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10023 Definition

Number of wireless channel accesses due to call re-establishment

Description

C10023 represents number of wireless channel accesses due to call re-establishment. Counter C10023 increments when BSC receives

Page 112: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

96 Confidential and Proprietary Information of ZTE CORPORATION

EST_IND message and access cause is call re-establishment in L3 message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10024 Definition

Number of wireless channel accesses due to IMSI detachment

Description

C10024 represents number of wireless channel accesses due to IMSI detachment. Counter C10024 increments when BSC receives EST_IND message and access cause is IMSI detachment in L3 message.

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10025 Definition

Number of wireless channel accesses due to other causes

Description

C10025 represents number of number of wireless channel accesses due to other causes. Counter C10025 increments when BSC receives EST_IND message. Wireless accesses causes are not Mobile Originated Call (MOC), Mobile Terminated Call (MTC), call re-establishment, location update (LOC), emergency call or IMSI detachment in L3 message.

Measurement Point

Refer point A4 as show in FIGURE 7.

Page 113: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 97

C h a p t e r 5

SDCCH Measurement

This chapter covers the following topics:

SDCCH Counters

SDCCH Counters SDCCH Counters provide statistics about:

SDCCH allocation

SDCCH seizure

SDCCH assignment

Related RF parameters can be adjusted by analyzing SDCCH counters.

FIGURE 8 - S D C C H AS S I G N M E N T F L O W

MS BTS BSC

CHL_REQ

CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

A2

IMM_ASS_CMD

IMM_ASS

SABM

EST_IND

A3

Table 13 lists all the SDCCH counters.

Page 114: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

98 Confidential and Proprietary Information of ZTE CORPORATION

TAB L E 13 S D C C H C O U N T E R S

Counter No. Counter Definition

C10101 Number of SDCCH call attempts during assignment

C10102 Number of successful SDCCH call attempts during assignment

C10103 Number of unsuccessful SDCCH call attempts during assignment

C10104 Number of SDCCH call attempts during handover

C10105 Number of successful SDCCH call attempts during handover

C10106 Number of unsuccessful SDCCH call attempts during handover

C10107 Number of SDCCH allocation attempts during assignment

C10108 Number of successful SDCCH allocations during assignment

C10109 Number of unsuccessful SDCCH allocations during assignment

C10110 Number of SDCCH allocation attempts during handover

C10111 Number of successful SDCCH allocations during handover

C10112 Number of unsuccessful SDCCH allocations during handover

C10113 Number of SDCCH assignment attempts

C10114 Number of successful SDCCH assignments

C10115 Number of unsuccessful SDCCH assignments

C10116 Number of SDCCH handover attempts

C10117 Number of successful SDCCH handovers

C10118 Number of unsuccessful SDCCH handovers with return

C10119 Number of unsuccessful SDCCH handovers without return

SDCCH Counters Explanation C10101 Definition

Number of SDCCH call attempts during assignment

Description

Number of SDCCH call attempts during assignment = Number of successful SDCCH call attempts during assignment + Number of unsuccessful SDCCH call attempts during assignment

Measurement Point

C10101 increments at the same time with the counters C10102 or C10103.

Page 115: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 5 - SDCCH Measurement

Confidential and Proprietary Information of ZTE CORPORATION 99

C10102 Definition

Number of successful SDCCH call attempts during assignment

Description

C10102 represents number of successful requests for SDCCH during assignment.

Initially MS sends CHL_REQ message to BSC through BTS and it triggers SDCCH allocation attempts.

After receiving CHL_REQ message, BSC attempts to allocate a channel for this request.

If SDCCH allocation succeeds, C10102 increments.

If return for application message shows that there is no SDDCH, BSC puts SDCCH request on waiting.

If the waiting succeeds, counter C10102 increments.

Measurement Point

Point A1 in FIGURE 8

C10103 Definition

Number of unsuccessful SDCCH call attempts during assignment

Description

C10103 represents number of unsuccessful SDCCH requests during assignment.

Initially MS sends CHL_REQ message to BSC through BTS and it triggers SDCCH allocation attempts.

After receiving CHL_REQ message, BSC attempts to allocate a channel for this request.

If SDCCH call attempt fails, C10103 increments.

If return for application message shows that there is no SDDCH, BSC puts SDCCH request on waiting.

If the waiting fails, counter C10103 increments.

Measurement Point

C10103 increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10104 Definition

Number of SDCCH call attempts during handover

Page 116: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

100 Confidential and Proprietary Information of ZTE CORPORATION

Description

Number of SDCCH call attempts during handover = Number of successful SDCCH call attempts during handover + Number of unsuccessful SDCCH call attempts during handover

Measurement Point

C10104 increments at the same time with the counters C10105 or C10106.

C10105 Definition

Number of successful SDCCH call attempts during handover

Description

C10105 represents number of successful requests for SDCCH during handover. SDCCH allocation attempts trigger due to RADIO_APPLY message from other channel instances. After receiving RADIO_APPLY message, BSC attempts to allocate a channel for this request.

If allocation of SDCCH succeed, C10105 increments.

If return for application message shows that there is no SDCCH BSC put this application on waiting.

If waiting succeeds, C10105 increments.

If return for application message shows that transceiver is faulty, the three counters remains change.

Measurement Point

Point A1 in FIGURE 8

C10106 Definition

Number of unsuccessful SDCCH call attempts during handover

Description

Counter C10106 represents number of unsuccessful SDCCH requests during handover. SDCCH allocation attempts trigger due to RADIO_APPLY message from other channel instances. After receiving RADIO_APPLY message, BSC attempts to allocate a channel for this request.

If SDCCH call attempt fails, C10106 increments.

If return for application message shows that there is no SDCCH, BSC puts this application on queuing.

If waiting for SDCCH fail, C10106 increments

If return for application message shows that transceiver is faulty, C10106 remains unchanged.

Page 117: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 5 - SDCCH Measurement

Confidential and Proprietary Information of ZTE CORPORATION 101

In other cases, C10106 increments.

Measurement Point

C10106 increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10107 Definition

Number of SDCCH allocation attempts during assignment

Description

C10107 represents number of SDCCH allocations requests during assignment.

Number of SDCCH allocation attempts during assignment = Number of successful SDCCH allocations during assignment + Number of unsuccessful SDCCH allocations during assignment

Measurement Point

C10107 increments at the same time with the counters C10108 or C10109.

C10108 Definition

Number of successful SDCCH allocations during assignment

Description

C10108 represents number of successful allocations of SDCCH during assignment. Initially BSC responds to SDCCH request when BSC sends CHL_ACT message to BTS to activate SDCCH. After successful allocation of SDCCH, counter C10108 get incremented.

Measurement Point

Point A2 in FIGURE 8

C10109 Definition

Number of unsuccessful SDCCH allocations during assignment

Description

C10109 represents number of SDCCH allocation failures during SDCCH assignment. Initially BSC responds to SDCCH request message from MS by seizing SDCCH successfully and BSC sends CHL_ACT message to BTS to activate SDCCH.

Counter C10109 increments in the following conditions:

SDCCH activation fails

Page 118: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

102 Confidential and Proprietary Information of ZTE CORPORATION

BSC receives incorrect SDCCH response message

Timer T9103 expires

BSC releases SDCCH normally or forcibly.

Measurement Point

C10109 increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10110 Definition

Number of SDCCH allocation attempts during handover

Description

C10110 represents number of SDCCH allocations requests during handover.

Number of SDCCH allocation attempts during handover = Number of successful SDCCH allocations during handover + Number of unsuccessful SDCCH allocations during handover

Measurement Point

C10110 increments at the same time with the counters C10111 or C10112.

C10111 Definition

Number of SDCCH successful allocations during handover

Description

C10111 represents number of successful allocation of SDCCH during handover. Initially BSC responds to SDCCH request by sending CHL_ACT message to BTS to activate SDCCH. After successful allocation of SDCCH, counter C10111 increments.

Measurement Point

C10111 increments when BSC correctly receives CHL_ACT_ACK message from BTS during handover.

C10112 Definition

Number of SDCCH unsuccessful allocations during handover

Description

C10112 represents number of SDCCH allocation failures. Initially BSC responds to SDCCH request message from MS by sending CHL_ACT message to BTS to activate SDCCH.

Page 119: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 5 - SDCCH Measurement

Confidential and Proprietary Information of ZTE CORPORATION 103

C10109 increments in the following conditions:

SDCCH activation fails

BSC receives incorrect SDCCH response message

Timer T9103 expires,

BSC releases SDCCH normally or forcibly

Measurement Point

C10109 increments when BSC receives the negative acknowledgment in response to the SDCCH ‘Channel Activation’ message.

C10113 Definition

Number of SDCCH assignment attempts

Description

Number of SDCCH assignment attempts = Number of successful SDCCH assignments + Number of unsuccessful SDCCH assignments

Measurement Point

C10113 increments at the same time with the counters C10114 or C10115.

C10114 Definition

Number of successful SDCCH assignments

Description

C10114 represents number of successful SDCCH assignments when BSC sends IMM_ASS message to MS to use the allocated SDCCH during assignment. If BSC successfully assigns SDCCH, counter C10114 increments.

Measurement Point

C10114 increments when BSC receives correct EST_IND message or assignment complete message.

C10115 Definition

Number of unsuccessful SDCCH assignments

Description

C10115 represents number of unsuccessful SDCCH assignments when BSC sends IMM_ASS message to MS to use the allocated SDCCH

Page 120: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

104 Confidential and Proprietary Information of ZTE CORPORATION

during assignment. If SDCCH assignment fails, counter C10115 and counter C10114 increments at the same time.

Measurement Point

C10115 increments when BSC receives the negative acknowledgment in response to the SDCCH ‘Assignment Command’ message.

C10116 Definition

Number of SDCCH handover attempts

Description

Number of SDCCH handover attempts = Number of successful SDCCH handovers + Number of unsuccessful SDCCH handovers

For successful handover, counter C10116 and counter C10117 increments at the same time.

For unsuccessful handover, counter C10116 and counter C10118 increments at the same time.

For other handover failures, counter C10116and counter C10119 increments at the same time.

Measurement Point

C10116 increments when BSC receives ASS_COM (for intra-cell handover) or HO_COM (for inter-cell handover) message

C10117 Definition

Number of successful SDCCH handovers

Description

C10117 represents number of successful SDCCH handovers. During handover, after MS successfully accesses new channel, BSC receives ASS_COM (for intra-cell handover) or HO_COM (for inter-cell handover) message. If handover is successful, this counter increment at the same time.

Measurement Point

C10117 increments when BSC receives ASS_COM (for intra-cell handover) or HO_COM (for inter-cell handover) message

C10118 Definition

Number of unsuccessful SDCCH handovers with return

Description

Page 121: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 5 - SDCCH Measurement

Confidential and Proprietary Information of ZTE CORPORATION 105

Not Implemented

C10119 Definition

Number of unsuccessful SDCCH handovers without return

Description

Not Implemented

Page 122: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

106 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank

Page 123: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 107

C h a p t e r 6

TCH/F Measurement

This chapter covers the following topics:

TCH/F Measurement Counters.

TCH/F Counters TCH/F measurement counters provide statistics for the following channels:

TCH/F allocation requests

TCH/F allocations

TCH/F assignment requests

TCH/F assignments

TCH/F handover requests

TCH/F handovers

Two types of Assignment flow:

Immediate Assignment

Common Assignment

Immediate Assignment: MS originates the assignment request, which BSC has to fulfill.

Common Assignment: MSC originates the assignment command for the MS.

FIGURE 9 and FIGURE 10 illustrates the two types of assignment flows.

Page 124: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

108 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 9 - I M M E D I AT E AS S I G N M E N T F L O W

MS BTS BSC

CHL_REQ

CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

A2

IMM_ASS_CMD

IMM_ASS

SABM

EST_IND

A3

FIGURE 10 - C O M M O N AS S I G N M E N T F L O W

MS BTS BSC

B1CHL_ACT

ASS_CMD

B2ASS_CMD

ASS_CMD

SABM

EST_IND

B3

MSC

CHL_ACT_ACK

UA

ASS_COMASS_COM

ASS_COMB4

Page 125: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 109

There are two types of handover flows:

Internal Handover

External Handover

FIGURE 11 and FIGURE 12 illustrates the two types of assignment flows.

Internal Handover: Handover without the involvement of MSC.

External Handover: Handover with the involvement of MSC.

FIGURE 11 - I N T E R N AL H AN D O V E R ( I N T R A-B S C H AN D O V E R )

MS BTS BSC

C1CHL_ACT

C2ASS_CMD

ASS_CMD

SABM

EST_IND

C3

MSC

CHL_ACT_ACK

UA

ASS_COMASS_COM

HO_PREFORM

MEAS_REP

MEAS_RES

FIGURE 12 - E X T E R N AL H AN D O V E R ( I N T R A-M S C H AN D O V E R )

MS BTS BSC

D1CHL_ACT

HO_REQ

D2

SABM

HO_DETECT

D3

MSC

CHL_ACT_ACK

UA

HO_COMHO_COM

HO_COM

HO_REQ_ACK

HO_DETECT

HO_ACCESS

PHY_INFO

Page 126: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

110 Confidential and Proprietary Information of ZTE CORPORATION

Table 18 lists all the TCH/F measurement counters.

T AB L E 18 T C H F M E AS U R E M E N T C O U N T E R S

Counter No. Definition

C10301 Number of TCH/F call attempts for assignment (signaling)

C10302 Number of successful TCH/F call attempts for assignment (signaling)

C10303 Number of unsuccessful TCH/F call attempts for assignment (signaling)

C10304 Number of TCH/F call attempts for handover (signaling)

C10305 Number of successful TCH/F call attempts for handover (signaling)

C10306 Number of unsuccessful TCH/F call attempts for handover (signaling)

C10307 Number of BSC attempts to allocate TCH/F for assignment (signaling)

C10308 Number of successful allocation of TCH/F for assignment (signaling)

C10309 Number of unsuccessful TCH/F allocation for assignment (signaling)

C10310 Number of BSC attempts to allocate TCH/F in case of handover (signaling)

C10311 Number of successful allocation of TCH/F in case of handover (signaling)

C10312 Number of unsuccessful TCH/F allocation in case of handover (signaling)

C10313 Number of BSC attempts to assign TCH/F (signaling)

C10314 Number of successful assignment of TCH/F (signaling)

C10315 Number of unsuccessful TCH/F assignment (signaling)

C10316 Number of handover attempts for TCH/F (signaling).

C10317 Number of successful TCH/F handover (Signaling)

C10318 Number of unsuccessful TCH/F handover (Signaling).

C10319 Number of BSC does not receives ‘Handover Fail’ message on the TCH/F (signaling)

C10320 Number of requests for TCH/F assignment (voice)

C10321 Number of successful request for TCH/F assignment (voice)

C10322 Number of unsuccessful request for TCH/F assignment (voice)

C10323 Number of requests for TCH/F handover (voice)

C10324 Number of successful request for TCH/F handover (voice)

C10325 Number of unsuccessful request for TCH/F handover failures (voice)

C10326 Number of BSC attempts to allocate TCH/F for assignment (voice version 1)

C10327 Number of successful allocation of TCH/F for assignment (voice version 1)

C10328 Number of unsuccessful allocation of TCH/F for assignment (voice version1)

C10329 Number of BSC attempts to allocate TCH/F for handover (voice version 1)

C10330 Number of successful TCH/F allocation for handover (voice version 1)

C10331 Number of unsuccessful TCH/F allocation for handover (voice version1)

C10332 Number of BSC attempts to allocate TCH/F for assignment (voice version 2)

Page 127: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 111

C10333 Number of successful allocation of TCH/F for assignment (voice version 2)

C10334 Number of unsuccessful TCH/F allocation for assignment (voice version2)

C10335 Number of BSC attempts to allocate TCH/F for handover (voice version 2)

C10336 Number of successful allocation of TCH/F for handover (voice version 2)

C10337 Number of unsuccessful TCH/F allocation for handover (voice version2)

C10338 Number of BSC attempts to allocate TCH/F for assignment (voice version3)

C10339 Number of successful allocation of TCH/F for assignment (voice version 3)

C10340 Number of unsuccessful TCH/F allocation for assignment (voice version 3)

C10341 Number of BSC attempts to allocate TCH/F for handover (voice version 3)

C10342 Number of successful allocation of TCH/F for handover (voice version 3)

C10343 Number of unsuccessful TCH/F allocation for handover (voice version 3)

C10344 Number of BSC attempts to assign TCH/F (Voice)

C10345 Number of successful assignment of TCH/F (Voice)

C10346 Number of unsuccessful TCH/F assignment (voice)

C10347 Number of handover attempts for TCH/F (Voice).

C10348 Number of successful TCH/F handover (Voice)

C10349 Number of unsuccessful TCH/F handover (Voice).

C10350 Number of BSC does not receives ‘Handover Fail’ message on the TCH/F (Voice)

C10351 Number of requests for TCH/F assignment (data)

C10352 Number of successful request for TCH/F assignment (data)

C10353 Number of unsuccessful request for TCH/F assignment (data)

C10354 Number of requests for TCH/F handover (data)

C10355 Number of successful request for TCH/F handover (data)

C10356 Number of unsuccessful request for TCH/F handover (data)

C10357 Number of BSC attempts to allocate TCH/F for assignment (data)

C10358 Number of successful allocation of TCH/F for assignment (data)

C10359 Number of unsuccessful TCH/F allocation for assignment (data)

C10360 Number of BSC attempts to allocate TCH/F for handover (data)

C10361 Number of successful allocation of TCH/F for handover (data)

C10362 Number of unsuccessful TCH/F allocation for handover (data)

C10363 Number of BSC attempts to assign TCH/F (data)

C10364 Number of successful assignment of TCH/F (data)

C10365 Number of unsuccessful TCH/F assignment (data)

C10366 Number of handover attempts for TCH/F (data).

C10367 Number of successful TCH/F handover (data)

C10368 Number of unsuccessful TCH/F handover (data).

C10369 Number of BSC does not receives ‘Handover Fail’ message on the TCH/F (data)

Page 128: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

112 Confidential and Proprietary Information of ZTE CORPORATION

TCHF Counters Explanation C10301 Definition

Number of TCH/F call attempts for assignment (signaling)

Description

Number of TCH/F call attempts for assignment = Number of successful TCH/F call attempts for assignment (signaling) + Number of unsuccessful TCH/F call attempts for assignment (signaling)

Calculation Formula

C10301 = C10302 + C10303

Measurement Point

Counter ‘C10301’ increments at the same time with counters ‘C10302’ or ‘C10303’.

C10302 Definition

Number of successful TCH/F call attempts for assignment (signaling)

Description

Request for TCH/F assignment only becomes successful when BSC successfully allocates the TCH/F. This counter keeps represents of number of successful requests for TCH/F assignment as a signaling channel.

Measurement Point

Counter ‘C10302’ increments when BSC successfully allocates the TCH/F.

C10303 Definition

Number of unsuccessful TCH/F call attempts for assignment (signaling)

Description

Request for TCH/F assignment becomes unsuccessful when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/F assignment as a signaling channel.

Page 129: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 113

Measurement Point

Counter ‘C10303’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10304 Definition

Number of TCH/F call attempts for handover (signaling)

Description

Number of TCH/F call attempts for handover (signaling) = Number of successful TCH/F call attempts for handover (signaling) + Number of unsuccessful TCH/F call attempts for handover (signaling)

Calculation Formula

C10304 = C10305 + C10306

Measurement Point

Counter ‘C10304’ has the measurement point same like counter ‘C10305’ or counter ‘C10306’.

C10305 Definition

Number of successful TCH/F call attempts for handover (signaling)

Description

Request for TCH/F assignment becomes successful when BSC successfully allocates the TCH/F. This counter is only to keep record of successful number of requests for TCH/F handover as a signaling channel.

Measurement Point

Counter ‘C10305’ increments when BSC successfully allocates the TCH/F.

C10306 Definition

Number of unsuccessful TCH/F call attempts for handover (signaling)

Description

Request for TCH/F assignment becomes unsuccessful when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/F handover as a signaling channel.

Page 130: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

114 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C10306’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10307 Definition

Number of BSC attempts to allocate TCH/F for assignment (signaling)

Description

Counter ‘C10307’ represents the number of BSC attempts to activate TCH/F to assign it to the MS, for the signaling purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (signaling) = Number of successful allocation of TCH/F for assignment (signaling) + Number of unsuccessful TCH/F allocation for assignment (signaling).

(C10307)= C10308 + C10309

Measurement Point

Counter ‘C10307’ increments at the same time with counters ‘C10308’ or ‘C10309’.

C10308 Definition

Number of successful allocation of TCH/F for assignment (signaling)

Description

Counter ‘C10308’ represents the number of BSC successfully activates the TCH/F to assign it to the MS as a signaling channel.

Measurement Point

Counter ‘C10308’ increments when BSC receives ‘Channel Activation Acknowledgement’ message from BTS, in case of successful allocation of the TCH/F.

C10309 Definition

Number of unsuccessful TCH/F allocation for assignment (signaling)

Description

Counter ‘C10309’ represents the number of unsuccessful attempt BSC makes to activate TCH/F to assign it to the MS as a signaling channel. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Page 131: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 115

Measurement Point

Counter ‘C10309’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10310 Definition

Number of BSC attempts to allocate TCH/F in case of handover (signaling)

Description

Counter ‘C10310’ represents the number of BSC attempts to activate TCH/F as a signaling channel in case of handover.

Calculation Formula

Number of BSC attempts to allocate TCH/F in case of handover (signaling) = Number of successful allocation of TCH/F in case of handover (signaling) + Number of TCH/F allocation failures in case of handover (signaling)

C10310 = C10311 + C10312

Measurement Point

Counter ‘C10310’ increments at the same time with counters ‘C10311’ or ‘C10312’.

C10311 Definition

Number of successful allocation of TCH/F in case of handover (signaling)

Description

Counter ‘C10311’ represents the number of BSC successfully activates the TCH/F as a signaling channel purpose when handovers for the MS.

Measurement Point

Counter ‘C10311’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 11 and D2-FIGURE 12).

C10312 Definition

Number of TCH/F allocation failures in case of handover (signaling)

Description

Counter ‘C10312’ represents the number of BSC failures to activate the TCH/F as a signaling channel when handovers for the MS.

Page 132: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

116 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C10312’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10313 Definition

Number of BSC attempts to assign TCH/F (signaling)

Description

Counter ‘C10313’ represents the number of BSC attempts to assign TCH/F to the MS as a signaling channel.

Calculation Formula

Number of BSC attempts to assign TCH/F (signaling) = Number of successful assignment of TCH/F (signaling) + Number of TCH/F allocation failures (signaling)

C10313 = C10314 + C10315

Measurement Point

Counter ‘C10313’ increments at the same time with counters ‘C10314’ or ‘C10315’.

C10314 Definition

Number of successful assignment of TCH/F (signaling)

Description

Counter ‘C10314’ represents the number of BSC successfully assigns the TCH/F as a signaling channel.

Measurement Point

Counter ‘C10314’ increments when BSC receives ‘Establish indication’ message from BTS.

C10315 Definition

Number of TCH/F assignment failures (signaling)

Description

Counter ‘C10315’ represents the number of BSC failures to assign TCH/F as a signaling channel.

Measurement Point

Counter ‘C10315’ increments when BSC receives negative acknowledgment in response to the ‘Assignment Command’ message.

Page 133: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 117

C10316 Definition

Number of handover attempts for TCH/F (signaling).

Description

Counter ‘C10316’ represents the number of BSC attempts to handover the MS on new TCH/F as a signaling channel. Handover involves both intra-cell and inter-cell handover.

Calculation Formula

Number of handover attempts for TCH/F (signaling) = Number of successful TCH/F handover (signaling) + Number of TCH/F handover failures (signaling).

C10316 = C10317 + C10318

Measurement Point

Counter ‘C10316’ has the measurement point same like counter ‘C10317’ or counter ‘C10318’.

C10317 Definition

Number of successful TCH/F handover (Signaling)

Description

Counter ‘C10317’ represents the number of BSC receives signaling about handover success on the new TCH/F, whether it is inter-cell or intra-cell handover.

Measurement Point

Counter ‘C10317” increments when BSC receives ‘Assignment Complete’ (intra-cell handover) or ‘Handover Complete’ message (inter-cell handover) on the new TCH/F. Refer to FIGURE 11-C3 and FIGURE 12-D3.

C10318 Definition

Number of unsuccessful TCH/F handover (Signaling).

Description

Counter ‘C10318’ represents the number of BSC failures to receive signaling about handover success on the new TCH/F, whether it is inter-cell or intra-cell handover.

Measurement Point

Counter ‘C10318” increments when BSC receives ‘Handover Fail’ message (inter-cell handover) on old TCH/F.

Page 134: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

118 Confidential and Proprietary Information of ZTE CORPORATION

C10319 Definition

Number of BSC does not receives ‘Handover Fail’ message on the TCH/F (signaling)

Description

Not Implemented

Measurement Point

Not Implemented

C10320 Definition

Number of requests for TCH/F assignment (voice)

Description

Number of requests for TCH/F assignment (voice) = Number of request for TCH/F assignment successful (voice) + Number of request for TCH/F assignment failures (voice)

Calculation Formula

C10320 = C10321 + C10322

Measurement Point

Counter ‘C10320’ increments at the same time with counters ‘C10321’ or ‘C10322’.

C10321 Definition

Number of request for TCH/F assignment successful (voice)

Description

Request for TCH/F assignment becomes successful when BSC successfully allocates the TCH/F. This counter is only to keep record of number of requests for TCH/F assignment as a voice channel.

Measurement Point

Counter ‘C10302’ increments when BSC successfully allocates the TCH/F.

Page 135: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 119

C10322 Definition

Number of request for TCH/F assignment failures (voice)

Description

Request for TCH/F assignment becomes unsuccessful when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/F assignment as a voice channel.

Measurement Point

Counter ‘C10303’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10323 Definition

Number of requests for TCH/F handover (voice)

Description

Number of requests for TCH/F handover (voice) = Number of successful request for TCH/F handover (voice) + Number of unsuccessful request for TCH/F handover (voice)

Calculation Formula

C10323 = C10324 + C10325

Measurement Point

Counter ‘C10323’ increments at the same time with counters ‘C10324’ or ‘C10325’.

C10324 Definition

Number of request for TCH/F handover successful (voice)

Description

Request for TCH/F handover becomes successful when BSC successfully allocates the TCH/F. This counter is only to keep record of number of requests for TCH/F handover as a voice channel.

Measurement Point

Counter ‘C10324’ increments when BSC successfully allocates the TCH/F.

Page 136: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

120 Confidential and Proprietary Information of ZTE CORPORATION

C10325 Definition

Number of request for TCH/F handover failures (voice)

Description

Request for TCH/F assignment becomes unsuccessful when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/F handover as a voice channel.

Measurement Point

Counter ‘C10325’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10326 Definition

Number of BSC attempts to allocate TCH/F for assignment (voice version 1)

Description

Counter ‘C10310’ represents the number of BSC attempts to activate TCH/F as a voice channel (version 1) for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (voice version 1) = Number of successful allocation of TCH/F for assignment (voice version 1) + Number of unsuccessful TCH/F allocation for assignment (voice version 1)

C10326 = C10327 + C10328

Measurement Point

Counter ‘C10326’ increments at the same time with counters ‘C10327’ or ‘C10328’.

C10327 Definition

Number of successful allocation of TCH/F for assignment (voice version 1)

Description

Counter ‘C10327’ represents the number of BSC successfully activates the TCH/F as a voice channel (version 1) for the assignment purpose.

Page 137: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 121

Measurement Point

Counter ‘C10327’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 13 and B2-FIGURE 14).

C10328 Definition

Number of TCH/F allocation failures for assignment (voice version1)

Description

Counter ‘C10312’ represents the number of times BSC fails to activate the TCH/F as a voice channel (version 1) for the assignment purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10328’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10329 Definition

Number of BSC attempts to allocate TCH/F for handover (voice version 1)

Description

Counter ‘C10329’ represents the number of times BSC attempts to activate TCH/F as a voice channel (version 1) for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (voice version 1) = Number of successful allocation of TCH/F for handover (voice version 1) + Number of unsuccessful TCH/F allocation for handover (voice version 1)

C10329 = C10330 + C10331

Measurement Point

Counter ‘C10329’ increments at the same time with counters ‘C10330’ or ‘C10331’.

Page 138: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

122 Confidential and Proprietary Information of ZTE CORPORATION

C10330 Definition

Number of successful allocation of TCH/F for handover (voice version 1)

Description

Counter ‘C10330’ represents the number of times BSC successfully activates the TCH/F as a voice channel (version 1) in case of handover.

Measurement Point

Counter ‘C10330’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE 10).

C10331 Definition

Number of TCH/F allocation fails for handover (voice version1)

Description

Counter ‘C10331’ represents the number of times BSC fails to activate the TCH/F as a voice channel (version 1) for the handover purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10331’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10332 Definition

Number of BSC attempts to allocate TCH/F for assignment (voice version 2)

Description

Counter ‘C10332’ represents the number of BSC attempts to activate TCH/F as a voice channel (version 2) for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (voice version 2) = Number of successful allocation of TCH/F for assignment (voice version 2) + Number of unsuccessful TCH/F allocation for assignment (voice version 2)

C10332 = C10333 + C10334

Page 139: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 123

Measurement Point

Counter ‘C10332’ increments at the same time with counters ‘C10333’ or‘C10334’.

C10333 Definition

Number of successful allocation of TCH/F for assignment (voice version 2)

Description

Counter ‘C10333’ represents the number of times BSC successfully activates the TCH/F as a voice channel (version 2) for the assignment purpose.

Measurement Point

Counter ‘C10333’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 9 and B2-FIGURE 10).

C10334 Definition

Number of unsuccessful TCH/F allocation for assignment (voice version2)

Description

Counter ‘C10334’ represents the number of times BSC fails to activate the TCH/F as a voice channel (version 2) for the assignment purpose. Causes for the failure are:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10334’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10335 Definition

Number of BSC attempts to allocate TCH/F for handover (voice version 2)

Description

Counter ‘C10335’ represents the number of BSC attempts to activate TCH/F as a voice channel (version 2) for the handover purpose.

Page 140: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

124 Confidential and Proprietary Information of ZTE CORPORATION

Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (voice version 2) = Number of successful allocation of TCH/F for handover (voice version 1) + Number of unsuccessful TCH/F allocation for handover (voice version 1)

C10335 = C10336 + C10337

Measurement Point

Counter ‘C10335’ increments at the same time with counters ‘C10336’ or ‘C10337’.

C10336 Definition

Number of successful allocation of TCH/F for handover (voice version 2)

Description

Counter ‘C10330’ represents the number of times BSC successfully activates the TCH/F as a voice channel (version 1) in case of handover.

Measurement Point

Counter ‘C10336’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE 10).

C10337 Definition

Number of unsuccessful TCH/F allocation for handover (voice version2)

Description

Counter ‘C10337’ represents the number times BSC fails to activate the TCH/F as a voice channel (version 2) for the handover purpose. Causes for the failure are:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10337’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10338 Definition

Number of BSC attempts to allocate TCH/F for assignment (voice version 3)

Page 141: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 125

Description

Counter ‘C10339’ represents the number of BSC attempts to activate TCH/F as a voice channel (version 3) for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (voice version 3) = Number of successful allocation of TCH/F for assignment (voice version 3) + Number of unsuccessful TCH/F allocation for assignment (voice version 3)

C10338 = C10339 + C10330

Measurement Point

Counter ‘C10338’ increments at the same time with counters ‘C10339’ or ‘C10330’.

C10339 Definition

Number of successful allocation of TCH/F for assignment (voice version 3)

Description

Counter ‘C10339’ represents the number of times BSC successfully activates the TCH/F as a voice channel (version 2) for the assignment purpose.

Measurement Point

Counter ‘C10339’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 9 and B2-FIGURE 10).

C10340 Definition

Number of TCH/F allocation failures for assignment (voice version3)

Description

Counter ‘C10340’ represents the number of times BSC fails to activate the TCH/F as a voice channel (version 2) for the assignment purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10340’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

Page 142: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

126 Confidential and Proprietary Information of ZTE CORPORATION

C10341 Definition

Number of BSC attempts to allocate TCH/F for handover (voice version 3)

Description

Counter ‘C10341’ represents the number of BSC attempts to activate TCH/F as a voice channel (version 3) for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (voice version 3) = Number of successful allocation of TCH/F for handover (voice version 3) + Number of unsuccessful TCH/F allocation failures for handover (voice version 3)

C10341 = C10342 + C10343

Measurement Point

Counter ‘C10341’ increments at the same time with counters ‘C10342’ or ‘C10343’.

C10342 Definition

Number of successful allocation of TCH/F for handover (voice version 3)

Description

Counter ‘C10342’ represents the number of times BSC successfully activates the TCH/F as a voice channel (version 3) in case of handover.

Measurement Point

Counter ‘C10342’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE 10).

C10343 Definition

Number of unsuccessful TCH/F allocation for handover (voice version 3)

Description

Counter ‘C10343’ represents the number of times BSC fails to activate the TCH/F as a voice channel (version 3) for the handover purpose. Causes for the failure are:

Timeout for timer T9103

Overload

Function (channel) not available

Page 143: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 127

Measurement Point

Counter ‘C10343’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10344 Definition

Number of BSC attempts to assign TCH/F (Voice)

Description

Counter ‘C10344’ represents the number of BSC attempts to assign TCH/F to the MS in order to carry the user speech.

Calculation Formula

Number of BSC attempts to assign TCH/F (Voice) = Number of successful assignment of TCH/F (Voice) + Number of TCH/F allocation failures (Voice)

C10344 = C10345 + C10346

Measurement Point

Counter ‘C10344’ increments at the same time with counters ‘C10345’ or ‘C10346’.

C10345 Definition

Number of successful assignment of TCH/F (Voice)

Description

Counter ‘C10345’ represents the number of times BSC successfully assigns TCH/F to the MS in order to carry the user speech.

Measurement Point

Counter ‘C10345’ increments when BSC receives ‘Establish indication’ message from BTS (A3-FIGURE 9).

C10346 Definition

Number of TCH/F assignment failures (voice)

Description

Counter ‘C10346’ represents the number of times BSC fails to assign TCH/F to the MS in order to carry the user speech.

Measurement Point

Counter ‘C10346’ increments when BSC receives negative acknowledgment in response to the ‘Assignment Command’ message.

Page 144: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

128 Confidential and Proprietary Information of ZTE CORPORATION

C10347 Definition

Number of handover attempts for TCH/F (Voice).

Description

Counter ‘C10347’ represents the number of BSC attempts to handover the MS on new TCH/F voice channel, in case of both intra-cell and inter-cell handover.

Calculation Formula

Number of handover attempts for TCH/F (Voice) = Number of successful TCH/F handover (Voice) + Number of TCH/F handover failures (Voice).

C10347 = C10348 + C10349

Measurement Point

Counter ‘C10347’ has the measurement point same like counter ‘C10348’ or counter ‘C10349’.

C10348 Definition

Number of successful TCH/F handover (Voice)

Description

Counter ‘C10348’ represents the number of times BSC receives signaling about handover success on the new TCH/F voice channel. Handover includes both inter-cell and intra-cell handover.

Measurement Point

Counter ‘C10348” increments when BSC receives ‘Assignment Complete’ (intra-cell handover) or ‘Handover Complete’ message (inter-cell handover) on the new TCH/F (Voice). Refer to FIGURE 11-C3 and FIGURE 12-D3.

C10349 Definition

Number of unsuccessful TCH/F handover (Voice).

Description

Counter ‘C10349’ represents the number of times BSC fails to receive signaling about handover success on the new TCH/F voice channel. Handover includes both inter-cell and intra-cell handover.

Measurement Point

Counter ‘C10349” increments when BSC receives ‘Handover Fail’ message (inter-cell handover) on old TCH/F.

Page 145: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 129

C10349 Definition

Number of BSC receives ‘Handover Fail’ message on the TCH/F (Voice)

Description

Not Implemented

Measurement Point

Not Implemented

C10350 Definition

Number of BSC does not receives ‘Handover Fail’ message on the TCH/F (Voice)

Description

Not Implemented

Measurement Point

Not Implemented

C10351 Definition

Number of requests for TCH/F assignment (data)

Description

Number of requests for TCH/F assignment (data) = Number of successful request for TCH/F assignment (data) + Number of unsuccessful request for TCH/F assignment (data)

Calculation Formula

C10351 = C10352 + C10353

Measurement Point

Counter ‘C10351’ increments at the same time with counters ‘C10352’ or ‘C10353’.

C10352 Definition

Number of requests for TCH/F assignment successful (data)

Description

Request for TCH/F assignment becomes successful when BSC successfully allocates the TCH/F. This counter is only to keep record of number of requests for TCH/F assignment as a data channel.

Page 146: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

130 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C10352’ increments when BSC successfully allocates the TCH/F.

C10353 Definition

Number of request for TCH/F assignment failures (data)

Description

Request for TCH/F assignment becomes unsuccessful when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/F assignment as a data channel.

Measurement Point

Counter ‘C10353’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10354 Definition

Number of requests for TCH/F handover (data)

Description

Number of requests for TCH/F handover (data) = Number of successful request for TCH/F handover (data) + Number of unsuccessful request for TCH/F handover (data)

Calculation Formula

C10354 = C10355 + C10356

Measurement Point

Counter ‘C10354’ increments at the same time with counters ‘C10355’ or ‘C10356’.

C10355 Definition

Number of request for TCH/F handover successful (data)

Description

Request for TCH/F handover becomes successful when BSC successfully allocates the TCH/F. This counter is only to keep record of number of requests for TCH/F handover as a data channel.

Measurement Point

Counter ‘C10355’ increments when BSC successfully allocates the TCH/F.

Page 147: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 131

C10356 Definition

Number of request for TCH/F handover failures (data)

Description

Request for TCH/F assignment becomes unsuccessful when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/F handover as a data channel.

Measurement Point

Counter ‘C10356’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10357 Definition

Number of BSC attempts to allocate TCH/F for assignment (data)

Description

Counter ‘C10357’ represents the number of BSC attempts to activate TCH/F as a data channel for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (data) = Number of successful allocation of TCH/F for assignment (data) + Number of unsuccessful TCH/F allocation for assignment (data)

C10357 = C10358 + C10359

Measurement Point

Counter ‘C10357’ increments at the same time with counters ‘C10358’ or ‘C10359’.

C10358 Definition

Number of successful allocation of TCH/F for assignment (data)

Description

Counter ‘C10358’ represents the number of times BSC successfully activates the TCH/F as a voice channel (data) for the assignment purpose.

Measurement Point

Counter ‘C10358’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 11 and B2-FIGURE 12).

Page 148: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

132 Confidential and Proprietary Information of ZTE CORPORATION

C10359 Definition

Number of unsuccessful TCH/F allocation for assignment (data)

Description

Counter ‘C10359’ represents the number of times BSC fails to activate the TCH/F as a data channel for the assignment purpose. Causes for the failure are:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10359’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10360 Definition

Number of BSC attempts to allocate TCH/F for handover (data)

Description

Counter ‘C10360’ represents the number of BSC attempts to activate TCH/F as a data channel for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (data) = Number of successful allocation of TCH/F for handover (data) + Number of unsuccessful TCH/F allocation for handover (voice version 3)

C10360 = C10361 + C10362

Measurement Point

Counter ‘C10360’ increments at the same time with counters ‘C10361’ or ‘C10362’.

C10361 Definition

Number of successful allocation of TCH/F for handover (data)

Description

Counter ‘C10361’ represents the number of BSC successfully activates the TCH/F as a data channel in case of handover.

Measurement Point

Counter ‘C10361’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE 10).

Page 149: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 133

C10362 Definition

Number of unsuccessful TCH/F allocation for handover (data)

Description

Counter ‘C10362’ represents the number of times BSC fails to activate the TCH/F as a data channel for the handover purpose. Causes for the failure are:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10362’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10363 Definition

Number of BSC attempts to assign TCH/F (data)

Description

Counter ‘C10363’ represents the number of BSC attempts to assign TCH/F to the MS in order to carry the user data.

Calculation Formula

Number of BSC attempts to assign TCH/F (data) = Number of successful assignment of TCH/F (data) + Number of unsuccessful TCH/F allocation failures (data)

C10363 = C10364 + C10365

Measurement Point

Counter ‘C10363’ increments at the same time with counters ‘C10364’ or ‘C10365’.

C10364 Definition

Number of successful assignment of TCH/F (data)

Description

Counter ‘C10364’ represents the number of times BSC successfully assigns TCH/F to the MS in order to carry the user data.

Measurement Point

Counter ‘C10364’ increments when BSC receives ‘Establish indication’ message from BTS (A3-FIGURE 9).

Page 150: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

134 Confidential and Proprietary Information of ZTE CORPORATION

C10365 Definition

Number of unsuccessful TCH/F assignment (data)

Description

Counter ‘C10365’ represents the number of times BSC fails to assign TCH/F to the MS in order to carry the user data.

Measurement Point

Counter ‘C10365’ increments when BSC receives negative acknowledgment in response to the ‘Assignment Command’ message.

C10366 Definition

Number of handover attempts for TCH/F (data).

Description

Counter ‘C10366’ represents the number of BSC attempts to handover the MS on new TCH/F data channel. Handover involves both intra-cell and inter-cell handover.

Calculation Formula

Number of handover attempts for TCH/F (data) = Number of successful of TCH/F handover (data) + Number of unsuccessful TCH/F handover (data).

C10366 = C10367 + C10368

Measurement Point

Counter ‘C10366’ has the measurement point same like counter ‘C10367’ or counter ‘C10368’.

C10367 Definition

Number of successful TCH/F handover (data)

Description

Counter ‘C10367’ represents the number of times BSC receives signaling about handover success on the new TCH/F data channel. Handover involves both intra-cell and inter-cell handover.

Measurement Point

Counter ‘C10367” increments when BSC receives ‘Assignment Complete’ (intra-cell handover) or ‘Handover Complete’ message (inter-cell handover) on the new TCH/F data channel. Refer to FIGURE 11-C3 and FIGURE 12-D3.

Page 151: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 6 - TCH/F Measurement

Confidential and Proprietary Information of ZTE CORPORATION 135

C10368 Definition

Number of unsuccessful TCH/F handover (data).

Description

Counter ‘C10368’ represents the number of times BSC fails to receive signaling about handover success on the new TCH/F data channel. Handover involves both intra-cell and inter-cell handover.

Measurement Point

Counter ‘C10368” increments when BSC receives ‘Handover Fail’ message (inter-cell handover) on old TCH/F.

C10369 Definition

Number of BSC does not receives ‘Handover Fail’ message on the TCH/F (data)

Description

Not Implemented

Page 152: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

136 Confidential and Proprietary Information of ZTE CORPORATION

This Page is intentionally blank

Page 153: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 137

C h a p t e r 7

Service Access Point Identifier 3

This chapter covers the following topics:

SAPI 3 Measurement

SAPI 3 Counters

SAPI 3 Introduction The SAPI is a 6-bit field in LAPDm and defines the type of user to which a message is addressed. Possible values of SAPI on Air-interface is SAPI=3 and SAPI=0. In this chapter SAPI 3 indicates SAPI=3.

This chapter only discusses the SAPI value equals to three (SAPI=3). SAPI value equals to three (SAPI=3) is used for Supplementary Services (SS) and Short Messages Services (SMS) on Air-interface.

If MS sends Short Message (SM), means MS originated SM (MO-SM). Similarly if MS receives Short Message (SM), means MS terminated SM (MT-SM). On the air interface SACCH/F, SACCH/H, SDCCH, FACCH/F and FACCH/H transport short message. Present system implements counters for SACH/F, SACH/H and SDDCH.

Page 154: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

138 Confidential and Proprietary Information of ZTE CORPORATION

SAPI 3 Counters FIGURE 13 illustrates measurement points for SAPI 3 measurement counters.

FIGURE 13 - S AP I 3 C O U N T E R S M E AS U R E M E N T P O I N T S

BTS BSC

EST_IND(SAPI=3)

EST_CONF(SAPI=3)

DTAP_IND(SAPI=3)

MSC

DTAP_IND(SAPI=3)

DATA_IND(SAPI=3)

A1

A5

A3

A2

A4

EST_REQ(SAPI=3)

Table 14 lists performance counters in SAPI 3 measurement.

TAB L E 14 S AP I 3 C O U N T E R S

Counter No. Counter Definition

C10201 Number of SAPI 3 link establishments on SACCH/F (MO-SM)

C10202 Number of SAPI 3 link establishments on SACCH/H (MO-SM)

C10203 Number of SAPI 3 link establishments on SDCCH (MO-SM)

C10204 Number of SAPI 3 link establishments on FACCH/F (MO-SM)

C10205 Number of SAPI 3 link establishments on FACCH/H (MO-SM)

C10206 Number of SAPI 3 link establishment requests on SACCH/F (MT-SM)

C10207 Number of SAPI 3 link establishment requests on SACCH/H (MT-SM)

C10208 Number of SAPI 3 link establishment requests on SDCCH (MT-SM)

C10209 Number of SAPI 3 link establishment requests on FACCH/F (MT-SM)

C10210 Number of SAPI 3 link establishment requests on FACCH/H (MT-SM)

Page 155: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 7 - Service Access Point Identifier 3

Confidential and Proprietary Information of ZTE CORPORATION 139

Counter No. Counter Definition

C10211 Number of successful SAPI 3 link establishments on SACCH/F (MT-SM)

C10212 Number of successful SAPI 3 link establishments on SACCH/H (MT-SM)

C10213 Number of successful SAPI 3 link establishments on SDCCH (MT-SM)

C10214 Number of successful SAPI 3 link establishments on FACCH/F (MT-SM)

C10215 Number of successful SAPI 3 link establishments on FACCH/H (MT-SM)

C10216 Number of DTAP messages on SDCCH uplink for point-to-point short messages

C10217 Number of DTAP messages on SDCCH downlink for point-to-point short messages

C10218 Number of DTAP messages on FACCH/F uplink for point-to-point short messages

C10219 Number of DTAP messages on FACCH/F downlink for point-to-point short messages

C10220 Number of DTAP messages on FACCH/H uplink for point-to-point short messages

C10221 Number of DTAP messages on FACCH/H downlink for point-to-point short messages

C10222 Number of DTAP messages on SACCH/F uplink for point-to-point short messages

C10223 Number of DTAP messages on SACCH/F downlink for point-to-point short messages

C10224 Number of DTAP messages on SACCH/H uplink for point-to-point short messages

C10225 Number of DTAP messages on SACCH/H downlink for point-to-point short messages

SAPI 3 Counters Explanation C10201 Definition

Number of SAPI 3 link establishments on SACCH/F (MO-SM)

Description

C10201 represents number of link establishments for mobile-originated short messages (MO-SM) through SACCH/F channel. BTS initially sends EST_IND message to BSC. C10201 increments after BSC receive EST_IND message with SAPI=3.

Measurement Point

Refer point A1 in FIGURE 13.

C10202 Definition

Page 156: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

140 Confidential and Proprietary Information of ZTE CORPORATION

Number of SAPI 3 link establishments on SACCH/H. (MO-SM)

Description

C10202 represents number of link establishment for mobile-originated short messages (MO-SM) through SACCH/H channel. BTS initially sends EST_IND message to BSC. C10202 increments after BSC receives EST_IND message with SAPI=3.

Measurement Point

Refer point A1 in FIGURE 13.

C10203 Definition

Number of SAPI 3 link establishment on SDCCH. (MO-SM)

Description

C10203 represents number of link establishment for mobile-originated short messages (MO-SM) through SDCCH. BTS initially sends EST_IND message to BSC. C10203 increments after BSC receives EST_IND message with SAPI=3.

Measurement Point

Refer point A1 in FIGURE 13.

C10204 Definition

Number of SAPI 3 link establishment on FACCH/F. (MO-SM)

Counter C10204 is not in the system at present.

C10205 Definition

Number of SAPI 3 link establishment on FACCH/H (MO-SM)

Counter C10205 is not in system at present.

C10206 Definition

Number of SAPI 3 link establishment requests on SACCH/F. (MT-SM)

Description

C10206 represents number of link establishment requests for mobile-terminated short messages (MO-SM) through SACCH/F channel. Initially MSC sends DTAP_IND message with SAPI=3 and BSC receives this message. If there is no link establishment for the short message

Page 157: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 7 - Service Access Point Identifier 3

Confidential and Proprietary Information of ZTE CORPORATION 141

between BSC and MS, BSC initiates link establishment flow and then C10206 increments.

Measurement Point

Refer point A2 in FIGURE 13.

C10207 Definition

Number of SAPI 3 link establishment requests on SACCH/H (MT-SM)

Description

C10207 represents number of link establishment requests for mobile-terminated short messages (MO-SM) through SACCH/H channel. Initially MSC sends DTAP_IND message and BSC receives this message with SAPI=3. If there is no link establishment for short message between BSC and MS, BSC initiates link establishment flow and then C10207 increments.

Measurement Point

Refer point A2 in FIGURE 13.

C10208 Definition

Number of SAPI 3 link establishment requests on SDCCH (MT-SM)

Description

C10209 represents number of link establishment requests for mobile-terminated short messages (MT-SM) through SDCCH. Initially MSC sends DTAP_IND message and BSC receives this message. If no link establishes for the short message between BSC and MS, the BSC initiates the link establishment flow and then C10208 increments.

Measurement Point

Refer point A2 in FIGURE 13.

C10209 Definition

Number of SAPI 3 link establishment requests on FACCH/F (MT-SM)

Description

Counter C10209 is not in the system at present.

C10210 Definition

Number of SAPI 3 link establishment requests on FACCH/H (MT-SM)

Page 158: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

142 Confidential and Proprietary Information of ZTE CORPORATION

Description

Counter C10210 is not in the system at present.

C10211 Definition

Number of successful SAPI 3 link establishments on SACCH/F (MT-SM)

Description

C10211 represents number of successful link establishments for mobile-terminated short messages (MT-SH) through SACCH/F channel. Initially BTS increments short message link establishment flow and sends link establishment confirmation message EST_CONF to BSC. This indicates successful establishment of short message link, C10211 increments at this point.

Measurement Point

Refer point A3 in FIGURE 13.

C10212 Definition

Number of successful SAPI 3 link establishments on SACCH/H channel (MT-SM)

Description

C10212 represents number of successful link establishments for mobile-terminated short messages (MT-SM) through SACCH/H channel. Initially BTS increments short message link establishment flow and sends link establishment confirmation message EST_CONF to BSC. This process indicates successful establishment of short message link, C10212 increments at this point.

Measurement Point

Refer point A3 in FIGURE 13.

C10213 Definition

Number of successful SAPI 3 link establishments on SDCCH (MT-SM)

Description

C10213 represents number of successful link establishments for mobile-terminated short messages (MT-SM) through SDCCH. Initially BTS increments short message link establishment flow and sends link establishment confirmation message EST_CONF to BSC. This process indicates successful establishment of short message link, C10213 increments at this point.

Page 159: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 7 - Service Access Point Identifier 3

Confidential and Proprietary Information of ZTE CORPORATION 143

Measurement Point

Refer point A3 in FIGURE 13.

C10214 Definition

Number of successful SAPI 3 link establishments on FACCH/F (MT-SM)

Description

Counter C10214 is not in the system at present.

C10215 Definition

Number of successful SAPI 3 link establishments on FACCH/H (MT-SM)

Description

Counter C10215 is not in the system at present.

C10216 Definition

Number of DTAP messages on SDCCH uplink for point-to-point short messages

Description

C10216 represents number of short messages in DTAP packets sent from MS through SDCCH to network side.

Measurement Point

Refer A4 in FIGURE 13.

C10217 Definition

Number of DTAP messages on SDCCH downlink for point-to-point short messages

Description

C10217 represents number of short messages in DTAP packets sent on SDCCH from network side to MS.

Measurement Point

Refer point A5 in FIGURE 13.

Page 160: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

144 Confidential and Proprietary Information of ZTE CORPORATION

C10218 Definition

Number of DTAP messages on FACCH/F uplink for point-to-point short messages.

Description

Counter C10218 is not in the system at present.

C10219 Definition

Number of DTAP messages on FACCH/F downlink for point-to-point short messages

Counter C10219 is not in the system at present.

C10220 Definition

Number of DTAP messages on FACCH/H uplink for point-to-point short messages

Counter C10220 is not in the system at present.

C10221 Definition

Number of DTAP messages on FACCH/H downlink for point-to-point short messages

Counter C10221 is not in system at present

C10222 Definition

Number of DTAP messages on SACCH/F uplink for point-to-point short messages.

Description

C10222 represents number of short messages in DTAP packets sent on SACCH/F from MS to network side.

Measurement Point

Refer point A4 in FIGURE 13.

Page 161: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 7 - Service Access Point Identifier 3

Confidential and Proprietary Information of ZTE CORPORATION 145

C10223 Definition

Number of DTAP messages on SACCH/F downlink for point-to-point short messages

Description

C10223 represents number of short messages in DTAP packets sent on SACCH/F from network side to MS.

Measurement Point

Refer point A5 in FIGURE 13.

C10224 Definition

Number of DTAP messages on SACCH/H uplink for point-to-point short messages

Description

C10224 represents number of short message in DTAP packets sent on SACCH/H from MS to network side.

Measurement Point

Refer point A4 in FIGURE 13.

C10225 Definition

Number of DTAP messages on SACCH/H downlink for point-to-point short messages

Description

10225 represents number of short messages in DTAP packets sent on SACCH/H from network side to MS.

Measurement Point

Refer point A5 in FIGURE 13.

Page 162: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

146 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 163: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 147

C h a p t e r 8

Radio Management Module Measurement

This chapter covers the following topics:

RMM Assignment Measurement

RMM Queue Measurement

RMM Assignment Measurement RR manages radio channels and resources. Radio resource consists of TCH, RR and LAPD signaling. RMM Assignment Measurement provides the statistics of radio channel assignment in RMM. If RMM can not apply radio channel first time, it attempts multiple times. The counters in RMM Assignment records problems from the perspective of a call.

RMM Assignment Counters Table 15 lists all the RMM Assignment Counters.

TAB L E 15 R M M AS S I G N M E N T C O U N T E R S

Counter No. Counter Definition

C10501 Number of general assignment executions for voice channel

C10502 Number of assignments for forced release attempts for voice.

C10503 Number of assignment executions for voice channel due to forced release.

C10504 Number of assignments for queuing attempts for voice channel

C10505 Number of assignments for execution for voice channel due to queuing

C10506 Total duration of successful assignment for queuing for voice channel

C10507 Number of successful assignments of queues for voice channel

C10508 Number of assignments for directed retry attempts for voice channel

Page 164: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

148 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C10509 Number of assignments for execution for voice channel due to directed retry

C10510 Number of general assignments for execution for data

C10511 Number of assignments for forced release attempts for data.

C10512 Number of assignment executions for data due to forced release.

C10513 Number of assignments for queuing attempts for data.

C10514 Number of assignments for execution for data due to queuing

C10515 Total duration of successful assignments for queuing for data

C10516 Number of successful assignments of queues for data

C10517 Number of assignments for directed retry attempts for data.

C10518 Number of assignment executions for data due to directed retry.

RMM Assignment Counters Explanation C10501 Definition

Number of general assignment executions for voice channel.

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. Then BSC attempts to assign a voice channel. C10501 increments for successful voice channel assignment.

Measurement Point

C10501 increments when BSC assigns a voice channel successfully.

C10502 Definition

Number of forced release attempts for voice channel assignments

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If BSC fails to assign a voice channel due to lack of radio resource, BSC attempts for forced release.

Measurement Point

C10502 increments when BSC attempts to release voice channel forcibly.

C10503 Definition

Number of voice channel assignment executions due to forced release.

Page 165: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 8 - Radio Management Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 149

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If BSC fails to assign a voice channel due to lack of radio resource, it performs force release. Force release is successful within fixed time and BSC acquires the voice channel for MS.

Measurement Point

C10503 increments after BSC executes force release assignment and acquires voice channel.

C10504 Definition

Number of queuing attempts for voice channel assignments.

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If BSC fails to assign a voice channel and the system does not allow forced release, BSC attempts for queuing.

Measurement Point

C10504 increments when BSC fails to assign voice channel and BSC attempts to execute queuing operations.

C10505 Definition

Number of voice channel assignment executions due to queuing

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If BSC fails to assign a voice channel and the system does not allow force release, BSC executes queuing. Queuing is successful within the fixed time.

Measurement Point

C10505 increments when BSC executes queuing.

C10506 Definition

Total duration of queuing for successful assignment of voice channel

Description

C10506 represents total duration for queuing in all voice channel assignment flows. To get the time spend on queuing assignment, subtract the time when voice channel enters queuing state from the

Page 166: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

150 Confidential and Proprietary Information of ZTE CORPORATION

current time. To get the total value, C10506 accumulates total time of queuing assignment.

Measurement Point

C10506 increments after BSC executes queuing operation successfully and obtains voice channel.

C10507 Definition

Number of successful assignment for queues for voice channel

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If the BSC fails in assigning a voice channel because of lack of radio resource, it performs queuing. Queuing is successful within the fixed time and the BSC obtains voice channel.

Measurement Point

C10507 increment, if queuing is successful and BSC acquires voice channel for MS.

C10508 Definition

Number of assignment for direct retry attempts for voice channel

Description

Initially the BSC fails in applying for a voice channel. Application cause for voice channel is direct retry or assignment. If the retry condition meets, BSC executes the direct retry.

Measurement Point

C10508 increments when BSC executes direct retry.

C10509 Definition

Number of assignment execution for voice channel due to directed retry.

Description

Initially the BSC executes direct retry. C10509 increments, if the BSC acquires the voice channel for MS.

Measurement Point

C10509 increments when the BSC obtains voice channel.

Page 167: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 8 - Radio Management Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 151

C10510 Definition

Number of general assignment for execution for data

Description

Initially the BSC receives RADIO_APPLY message during channel assignment flow. BSC attempts to assign a data channel. C10510 increments, if data channel assignment is successful.

Measurement Point

C10510 increments when the BSC assigns a data channel successfully.

C10511 Definition

Number of assignment for forced release attempts for data

Description

Initially the BSC receives RADIO_APPLY message during channel assignment flow and the BSC attempts to assign a data channel. If the BSC fails in assigning a data channel due to lack of radio resource, then BSC attempts for forced release and C10511 increments.

Measurement Point

C10511 increments when the BSC attempts for data channel.

C10512 Definition

Number of assignment execution for data due to forced release.

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If BSC fails in assigning a data channel due to lack of radio resource, the BSC performs forced release. If BSC acquires required data channel for MS within fixed time and forced release is successful, C10512 increments.

Measurement Point

C10512 increments when BSC acquires required data channel for MS within fixed time by forced release.

C10513 Definition

Number of assignment for queuing attempts for data.

Page 168: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

152 Confidential and Proprietary Information of ZTE CORPORATION

Description

Initially BSC receives RADIO_APPLY message during channel assignment flow. If BSC fails in assigning a data channel and system does not allow forced release, the BSC attempts for queuing. Queuing attempt for data channel is successful within fixed time to wait until system release other data channel. At successful attempt for data channel after waiting in a queue, C10513 increments.

Measurement Point

C10513 increments when BSC attempts for queuing for data channel.

C10514 Definition

Number of assignment execution for data due to queuing.

Description

Initially the BSC fails in assigning a data channel because no resource is available. Then the BSC performs queuing operation. If the required channel is available within fixed time after queuing operation and the queuing operation is successful, C10514 increment.

Measurement Point

C10514 increments when queuing operation successful and BSC obtains data channel.

C10515 Definition

Total duration of successful assignment for queuing for data

Description

C10515 represents total duration for queuing in all data channel assignment flows. To get the time spent on queuing assignment, subtract the time when the data channel enters queuing state from the current time. To get the value of C10515, accumulate total time spent on queuing assignment.

Measurement Point

C10515 increments after BSC executes queuing operation successfully and obtains data channel.

C10516 Definition

Number of successful assignment of queues for data

Page 169: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 8 - Radio Management Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 153

Description

Initially the BSC receives RADIO_APPLY message during channel assignment flow. If the BTS fails in activating a data channel because of lack of radio resource, it performs queuing. Queuing is successful within fixed time and BSC acquires the data channel for MS.

Measurement Point

C10516 increments when queuing is successful and BSC obtains voice channel

C10517 Definition

Number of assignment for directed retry attempts for data.

Description

Initially the BSC fails in applying for a data channel. Application cause for data channel is direct retry or assignment. If retry condition is met, BSC executes the direct retry.

Measurement Point

C10517 increments when BSC executes direct retry.

C10518 Definition

Number of assignment execution for data due to directed retry.

Description

Initially the BSC executes direct retry. C10518 increments, if BSC acquires the data channel.

Measurement Point

C10518 increments when BSC obtains data channel.

RMM Queue Measurement RMM Queue Measurement involves counters that provide statistics such as queuing due to a temporary failure at the time of acquiring radio resources. These counter include average duration, total duration, number of queues, and number of successful queues. Unit of the measurement is the cell.

Table 16 lists all RMM queuing counters.

Page 170: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

154 Confidential and Proprietary Information of ZTE CORPORATION

RMM Queue Counters

TAB L E 16 R M M AS S I G N M E N T Q U E U E C O U N T E R

Counter No. Counter Definition

C11001 Average length of queue array

C11002 Total duration of queue

C11003 Total number of queues

C11004 Total duration of successful queues

C11005 Total number of successful queues

Above counters not implemented.

Page 171: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 155

C h a p t e r 9

RMM Call Drop Measurement

This chapter covers the following topics:

RMM Call Drop Counters

RMM Call Drop Counters RMM Call Drop Counters provide statistics such as:

SDCCH, TCH/F, and TCH/Hs status.

Signalling, voice, and data type services.

Call drops due to contact loss between RMM and SMM

BTS-site radio link failure and LAPD link failure.

Call drops due to OMC-R force release.

Table 17 lists all RMM call drop counters.

TAB L E 17 R M M C AL L D R O P C O U N T E R S

Counter No. Counter Definition

C10601 Number of failures due to loss of contact with SMM

C10602 Number of radio link failures

C10603 Number of LAPD link failures

C10604 Number of OMC-R forced releases

C10605 Number of forced releases by other calls

C10606 Number of other failures

C10607 Number of failures due to loss of contact with SMM

C10608 Number of radio link failures

C10609 Number of LAPD link failures

C10610 Number of OMC-R forced releases

Page 172: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

156 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C10611 Number of forced releases from other calls

C10612 Number of other failures

C10613 Number of failures due to loss of contact with SMM

C10614 Number of radio link failures

C10615 Number of LAPD link failures

C10616 Number of OMC-R forced releases

C10617 Number of forced releases by other calls

C10618 Number of other failures (On TCH/F voice)

C10619 Number of failures due to loss of contact with SMM

C10620 Number of radio link failures

C10621 Number of LAPD link failures

C10622 Number of OMC-R forced releases

C10623 Number of forced releases by other calls

C10624 Number of other failures

C10625 Number of failures due to loss of contact with SMM

C10626 Number of radio link failures

C10627 Number of LAPD link failures

C10628 Number of OMC-R forced releases

C10629 Number of forced releases by other calls

C10630 Number of other failures

C10631 Number of failures due to loss of contact with SMM

C10632 Number of radio link failures

C10633 Number of LAPD link failures

C10634 Number of OMC-R forced releases

C10635 Number of forced releases by other calls

C10636 Number of other failures

C10637 Number of failures due to loss of contact with SMM

C10638 Number of radio link failures

C10639 Number of LAPD link failures

C10640 Number of OMC-R forced releases

C10641 Number of forced releases by other calls

C10642 Number of other failures

C10643 Number of SDCCH call drops

C10644 Number of TCH/F call drops

C10645 Number of TCH/H call drops

C10646 Call drop on SDCCH due to handover failure

C10647 Call drop on TCH/F signaling due to handover failure

Page 173: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 157

Counter No. Counter Definition

C10648 Call drop on TCH/F voice due to handover failure

C10649 Call drop on TCH/F data due to handover failure

C10650 Call drop on TCH/H signaling due to handover failure

C10651 Call drop TCH/H voice due to handover failure

C10652 Call drop on TCH/H data due to handover failure

Call Drop Counters Explanation C10601 Definition

Number of failures due to loss of contact between RMM and SMM (On SDCCH)

Description

C10601 represents number of call drops due to contact loss between RMM and SMM on SDCCH. ZXG10-BSC system consists of one System Management Module (SMM) and maximum of eight RMMs

During STATUS_QUERY_STATUS_CONFERMATION, RMM sets timer T12

If timer T12 expires for three times consecutively, the link between SMM and RMM breaks and counter C10601 increments.

During EST_IND link establishment flow, RMM set Timer T3.

If T3 timer expires, the link between SMM and RMM breaks and counter C10601 increments.

Measurement Point

C10601 increments when Timer T12 expires for three times consecutively or timer T3 expires.

C10602 Definition

Number of radio link failures (On SDCCH)

Description

C10603 represents number of call drops due to radio link failure on SDCCH.

Measurement Point

C10602 increments when BSC receives ABIS_CONNECTFAILIND message on Abis-interface.

Page 174: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

158 Confidential and Proprietary Information of ZTE CORPORATION

C10603 Definition

Number of LAPD link failures (On SDCCH)

Description

C10603 represents number of call drops due to LAPD link failure on SDCCH.

Measurement Point

C10603 increments when BSC receives LAPD link break message.

C10604 Definition

Number of OMC-R forced releases (On SDCCH)

Description

C10604 represents number of call drops due to SDCCH forced release.

Measurement Point

C10604 increments when BSC receives force release message from OMC-R.

C10605 Definition

Number of forced releases by other calls (On SDCCH)

Description

C10605 represents number of call drops due to force release from high priority calls on SDCCH. Initially BSC receives force release message from BTS for high priority calls and C10605 increments.

Measurement Point

C10605 increments when BSC receives forced release message from BTS.

C10606 Definition

Number of other failures (On SDCCH)

Description

C10606 represents number of call drops due to causes other than above-mentioned cases on SDCCH.

Page 175: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 159

Other causes such as:

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during channel activation.

Measurement Point

C10606 increments when timers T3107, T1, and T3103 expire.

C10607 Definition

Number of failures due to loss of contact between SMM and RMM (On TCH/F signaling channel)

Description

Counter C10607 represents number of call drops due to loss of contact between RMM and SMM on TCH/F channel. ZXG10-BSC system comprises one System Management Module (SMM) and maximum of eight Radio Management Modules (RMMs)

During STATUS_QUERY_STATUS_CONFERMATION RMM sets timer T12.

If timer T12 expires for three times consecutively, the link between SMM and RMM breaks and counter C10607 increments.

During EST_IND link establishment flow, RMM sets Timer T3.

C10607 increments, if T3 timer expires, the link between SMM and RMM breaks.

Measurement Point

C10607 increments when timer T12 expires for three times consecutively or timer T3 expires.

C10608 Definition

Number of radio link failures (On TCH/F signaling channel)

Description

C10608 represents number of call drops due to radio link failure on TCH/F signaling channel.

Measurement Point

C10608 increments when BSC receives ABIS_CONNECTFAILIND message on Abis-interface.

Page 176: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

160 Confidential and Proprietary Information of ZTE CORPORATION

C10609 Definition

Number of LAPD link failures (On TCH/F signaling channel)

Description

C10609 represents number of call drops due to LAPD link failure on TCH/F signaling channel.

Measurement Point

C10609 increments when BSC receives LAPD link break message.

C10610 Definition

Number of OMC-R forced releases (On TCH/F signaling channel)

Description

C10610 represents number of call drops due to forced release message from OMC-R on TCH/F signaling channel.

Measurement Point

C10610 increments when BSC receives forced release message from OMC-R.

C10611 Definition

Number of forced release of other calls (On TCH/F signaling channel)

Description

C10611 represents number of call drops due to forced release of other calls on TCH/F signaling channel.

Measurement Point

C10611 increments when BSC receives forced release message form other calls.

C10612 Definition

Number of other failures (On TCH/F signaling channel)

Description

Counter C10612 represents number of call drops due to other causes except above-mentioned counters on TCH/F signaling channel.

Page 177: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 161

Other causes such as:

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during channel activation.

Measurement Point

C10612 increments when timers T3107, T1, and T3103 expire.

C10613 Definition

Number of link failures due to loss of contact between SMM and RMM (On TCH/F voice channel)

Description

Counter C10613 represents number of call drops due to loss of contact between RMM and SMM on TCH/F channel. ZXG10-BSC system comprises one System Management Module (SMM) and maximum eight Radio Management Modules (RMMs)

During TATUS_QUERY_STATUS_CONFERMATION, RMM sets timer T12.

If timer T12 expires for three times consecutively, the link between SMM and RMM breaks and counter C10613 increments.

During EST_IND link establishment flow, RMM sets Timer T3.

If T3 timer expires, the link between SMM and RMM breaks and counter C10613 increments.

Measurement Point

C10613 increments counting when timer T12 expires for three times consecutively or timer T3 expires.

C10614 Definition

Number of radio link failures (On TCH/F voice channel)

Description

Counter C10614 represents number of call drops due to radio link failure on TCH/F voice channel.

Measurement Point

C10614 increments when BSC receives ABIS_CONNECTFAILIND message on Abis-interface.

Page 178: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

162 Confidential and Proprietary Information of ZTE CORPORATION

C10615 Definition

Number of LAPD link failures (On TCH/F voice channel)

Description

C10415 represents number of call drops due to LAPD link failure on TCH/F voice channel.

Measurement Point

C10615 increments when BSC receives LAPD link break message.

C10616 Definition

Number of forced release of TCH/F voice channel from OMC-R (On TCH/F voice channel)

Description

C10616 represents number of call drops due to TCH/F voice channel force release from OMC-R.

Measurement Point

C10616 increments when BSC receives force release message from OMC-R.

C10617 Definition

Number of forced release of other calls on TCH/F voice channel (On TCH/F voice channel).

Description

C10617 represents number of call drops due to force release of TCH/F voice channel.

Measurement Point

C10617 increments when BSC receives force release message from other calls.

C10618 Definition

Number of other failures (On TCH/F voice channel)

Description

C10618 represents number of call drops due to other causes except above-mentioned counters on TCH/F voice channel.

Page 179: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 163

Other causes are:

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during channel activation.

Measurement Point

C10618 increments when timers T3107, T1, and T3103 expire.

C10619 Definition

Number of TCH/F data channel failures due to loss of contact between SMM and RMM (On TCH/F data channel)

Description

C10619 represents number of call drops due to loss of contact between RMM and SMM on TCH/F data channel. ZXG10-BSC system comprises one System Management Module (SMM) and maximum eight Radio Management Modules (RMMs)

During TATUS_QUERY_STATUS_CONFERMATION, RMM sets timer T12.

If timer T12 expires for three times consecutively, the link between SMM and RMM breaks and counter C10619 increments.

During EST_IND link establishment flow, RMM sets Timer T3.

C10619 increments if T3 timer expires and link breaks between SMM and RMM.

Measurement Point

C10619 increments when timer T12 expires for three times consecutively or the timer T3 expires.

C10620 Definition

Number of radio link failures (On TCH/F data channel)

Description

C10620 represents number of call drops due to radio link failure on TCH/F data channel.

Measurement Point

C1020 increments when BSC receives ABIS_CONNECTFAILIND message on Abis-interface.

Page 180: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

164 Confidential and Proprietary Information of ZTE CORPORATION

C10621 Definition

Number of LAPD link failures (On TCH/F data channel)

Description

Counter C10621 represents number of call drops due to LAPD link failure on TCH/F data channel.

Measurement Point

Counter C10621 increments when BSC receives LAPD link break message.

C10622 Definition

Number of OMC-R forced release.

Description

Counter C10622 represents number of call drops due to force release from OMC-R on TCH/F data channel.

Measurement Point

Counter C10622 increments when BSC receives force release message from OMC-R.

C10623 Definition

Number of forced releases of other calls on TCH/F data channel.

Description

C10623 represents number of call drops due to force release of other calls on TCH/F data channel.

Measurement Point

C10623 increments when BSC receives force release message from other calls.

C10624 Definition

Number of other failures (On TCH/F data channel)

Description

Counter C10624 represents number of call drops due to other causes except above-mentioned counters on TCH/F data channel.

Other causes are:

Page 181: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 165

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during TCH/F data channel activation.

Measurement Point

C10624 increments when timers T3107, T1, and T3103 expire.

C10625 Definition

Number of failures due to loss of contact between SMM and RMM (On TCH/H signaling channel)

Description

Counter C10625 represents number of call drops due to loss of contact between RMM and SMM on TCH/F signaling channel. ZXG10-BSC system comprises one System Management Module (SMM) and maximum eight Radio Management Modules (RMMs).

During STATUS_QUERY_STATUS_CONFERMATION, RMM sets timer T12.

If timer T12 expires for three times consecutively, the link between SMM and RMM breaks and counter C10625 increments.

During EST_IND link establishment flow, RMM sets Timer T3.

C10625 increments if T3 timer expires and link breaks between SMM and RMM.

Measurement Point

C10625 increments when timer T12 expires for three times consecutively or timer T3 expires.

C10626 Definition

Number of radio link failures (On TCH/H signaling channel)

Description

C10626 represents number of call drops due to radio link failure on TCH/H signaling channel.

Measurement Point

C10626 increments when BSC receives Abis Connect_Fail_Ind message on Abis-interface.

Page 182: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

166 Confidential and Proprietary Information of ZTE CORPORATION

C10627 Definition

Number of LAPD link failures (On TCH/H signaling channel)

Description

C10627 represents number of call drops due to LAPD link failure on TCH/H signaling channel.

Measurement Point

C10627 increments when BSC receives LAPD link break message TCH/H signaling channel.

C10628 Definition

Number of TCH/H signaling channel forced releases from OMC-R.

Description

C10628 represents number of call drops due to forced release of TCH/H signaling channel from OMC-R.

Measurement Point

C10628 increments when BSC receives TCH/H signaling channel forced release message from OMC-R.

C10629 Definition

Number of forced releases by other calls

Description

C10629 represents the number of call drops due to forced release of other calls on TCH/H signaling channel.

Measurement Point

C10629 increments when BSC receives forced release message from other calls.

C10630 Definition

Number of other failures

Description

Counter C10630 represents number of call drops due to other causes except above-mentioned counters on TCH/H signaling channel.

Page 183: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 167

Other causes are:

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during TCH/F data channel activation.

Measurement Point

C10630 increments when timers T3107, T1, and T3103 expire.

C10631 Description

Number of failures due to loss of contact between SMM and RMM (On TCH/H voice channel)

Description

Counter C10631 represents number of call drops due to loss of contact between RMM and SMM on TCH/H voice channel. ZXG10-BSC system comprises one System Management Module (SMM) and maximum eight Radio Management Modules (RMMs)

During STATUS_QUERY_STATUS_CONFERMATION, RMM sets timer T12.

If timer T12 expires for three times consecutively, the link between SMM and RMM breaks and counter C10631 increments.

During EST_IND link establishment flow, RMM sets Timer T3.

C10631 increments if T3 timer expires and link breaks between SMM and RMM.

Measurement Point

C10631 increments to count when timer T12 expires for three times consecutively or timer T3 expires.

C10632 Definition

Number of radio link failures (On TCH/H voice channel)

Description

C10632 represents number of call drops due to radio link failure on TCH/H voice channel.

Measurement Point

C10632 increments when BSC receives ABIS_CONNECTFAILIND message on Abis-interface.

Page 184: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

168 Confidential and Proprietary Information of ZTE CORPORATION

C10633 Definition

Number of LAPD link failures (On TCH/H voice channel)

Description

C10633 represents number of call drops due to LAPD link failure on TCH/H voice channel.

Measurement Point

C10633 increments when BSC receives LAPD link break message.

C10634 Definition

Number of forced release of TCH/H voice channel from OMC-R (On TCH/H voice channel)

Description

C10634 represents number of call drops due to force release of TCH/H voice channel from OMC-R.

Measurement Point

C10634 increments when BSC receives TCH/H voice channel forced release message from OMC-R.

C10635 Definition

Number of forced TCH/H voice channel releases from other calls (On TCH/H voice channel)

Description

C10635 represents number of call drops due to forced release of other calls on TCH/H voice channel.

Measurement Point

C10635 increments when BSC receives forced release message from other calls.

C10636 Definition

Number of other failures (On TCH/H voice channel)

Description

Counter C10636 represents number of call drops due to other causes except above-mentioned counters on TCH/H voice channel.

Page 185: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 169

Other causes are:

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during TCH/F data channel activation.

Measurement Point

C10636 increments when Timers T3107, T1, and T3103 expire.

C10637 Definition

Number of failures due to loss of contact between SMM and RMM (On TCH/H data channel)

Description

C10637 represents number of call drops due to loss of contact between RMM and SMM on TCH/H data channel.

Measurement Point

C10637 increments when timer T12 expires for three times consecutively or timer T3 expires.

C10638 Definition

Number of radio link failures (On TCH/H data channel)

Description

C10638 represents number of call drops due to radio link failure on TCH/H data channel.

Measurement Point

C10638 increments when BSC receives ABIS_CONNECTFAILIND message on Abis-interface.

C10639 Definition

Number of LAPD link failures (On TCH/H data channel)

Description

C10639 represents number of call drops due to LAPD link failure on TCH/H data channel.

Page 186: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

170 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C10639 increments when BSC receives LAPD link break message.

C10640 Definition

Number of TCH/H data channel forced release from OMC-R (On TCH/H data channel)

Description

C10640 represents number of call drops due to forced release of TCH/H data channel from OMC-R on.

Measurement Point

C10640 increments when BSC receives forced release message from OMC-R.

C10641 Definition

Number of forced releases from calls (On TCH/H data channel)

Description

C10641 represents the number of call drops due to forced release of other calls on TCH/H data channel.

Measurement Point

C10641 increments when BSC receives forced release message from other calls.

C10642 Definition

Number of other failures (On TCH/H data channel)

Description

C10642 represents the number of call drops due to other causes except above-mentioned counters on TCH/H data channel.

Other causes are:

T3107 timer expires in ASSIGNING status.

T1 timer expires in WAIT_ACCESS status during radio resource valid to assignment or handover complete.

T3103 timer expires when BSC receives EST_IND from MS during TCH/F data channel activation.

Measurement Point

C10642 increments when Timers T3107, T1, and T3103 expire.

Page 187: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 171

C10643 Definition

Number of SDCCH calls drops

Description

Counter C10643 represents number of call drops due to radio link failure, LAPD broken link and handover failure on SDCCH.

At present, the system does not represent failures due to following four types of causes:

Loss of contact with the SMM

Forced release from OMC-R

Forced release by other calls

Any other causes

Measurement Point

C10643 increments due to radio link, LAPD link and handover failure.

C10644 Definition

Number of TCH/F calls drops

Description

C10644 represents number of call drops due to radio link failure, LAPD link break and handover failure on TCH/F channel.

At present, the system does not represent the failures due to following four types of causes:

Loss of contact with the SMM

Forced release from OMC-R

Forced release by other calls

Any other causes

Measurement Point

C10644 increments due to radio link failure, LAPD link break and handover failure.

C10645 Definition

Number of TCH/H calls drops

Page 188: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

172 Confidential and Proprietary Information of ZTE CORPORATION

Description

C10645 represents the number of call drops due to all causes on TCH/H that includes above-mentioned radio link failure, LAPD link break and handover failure.

At present, the system does not represent the failures due to following four types of causes:

Loss of contact with the SMM

Forced release from OMC-R

Forced release by other calls

Any other causes

Measurement Point

C10645 increments when radio link fails, LAPD link breaks and handover fails.

C10646 Definition

Call drop on SDCCH due to handover failure

Description

C10646 represents the total number of call drops due to handovers on SDCCH.

Measurement Point

C10646 increments when Timers T3103, 3107, and T8 expire.

C10647 Definition

Call drop due to handover failure on TCH/F signaling

Description

C10647 represents the total number of call drops due to handovers on TCH/F signaling channel.

Measurement Point

C10647 increments when timers T3103, T3107, and T8 expire.

C10648 Definition

Call drop due to handover failure on TCH/F voice

Page 189: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 9 - RMM Call Drop Measurement

Confidential and Proprietary Information of ZTE CORPORATION 173

Description

C10648 represents total number of call drops due to handovers on TCH/F voice channel.

Measurement Point

C10648 increments when timers T3103, 3107, and T8 expire

C10649 Description

Call drop due to handover failure on TCH/F data

Description

C10649 represents total number of call drops due to handovers on TCH/F data channel.

Measurement Point

C10649 increments when timers T3103, 3107, and T8 expire.

C10650 Definition

Call drop due to handover failure on TCH/H signaling

Description

C10650 represents the total number of call drops due to handovers on TCH/H signaling channel.

Measurement Point

C10650 increments when timers T3103, 3107, and T8 expire.

C10651 Definition

Call drop due to handover failure (On TCH/H voice)

Description

C10651 represents total number of call drops due to handovers on TCH/H voice channel.

Measurement Point

Counter C10651 increments when timers T3103, 3107, and T8 expire.

C10652 Definition

Call drop due to handover failure (On TCH/H data)

Page 190: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

174 Confidential and Proprietary Information of ZTE CORPORATION

Description

C10652 represents the total number of call drops due to handovers on TCH/H data channel.

Measurement Point

C10652 increments when timers T3103, 3107, and T8 expire.

Page 191: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 175

C h a p t e r 10

Handover Cause Measurement

This chapter covers the following topics:

Handover Cause Counters

Handover Cause Counters Handover Cause Counters provides statistics for number of handover out attempts due to various handover causes. BSC determines the handover upon MS measurement report. Handover measurement reports are of great significance at the time of evaluation, adjustment and RF parameters optimization of the network.

Handover Cause Counters Table 18 lists handover cause counters.

TAB L E 18 H AN D O V E R C AU S E C O U N T E R S

Counter No. Counter Definition

C10801 Number of handover attempts due to direct retry

C10802 Number of handover attempts due to uplink received strength (on SDCCH)

C10803 Number of handover attempts due to downlink received strength (on SDCCH)

C10804 Number of handover attempts due to uplink interference (on SDCCH)

C10805 Number of handover attempts due to downlink interference(on SDCCH)

C10806 Number of handover attempts due to C/I RATIO (on SDCCH)

C10807 Number of handover attempts due to PBGT (on SDCCH)

C10808 Number of handover attempts due to large TA (on SDCCH)

C10809 Number of handover attempts due to MSC request (on SDCCH)

C10810 Number of handover attempts due to traffic (on SDCCH)

Page 192: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

176 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C10811 Handover attempt due to any other reason (on SDCCH)

C10812 Handover attempt due to uplink received strength (on TCH/F)

C10813 Handover attempt due to downlink received strength (on TCH/F)

C10814 Handover attempt due to uplink interference (on TCH/F)

C10815 Handover attempt due to downlink interference (on TCH/F)

C10816 Handover attempt due to C/I RATIO (on TCH/F)

C10817 Handover attempt due to PBGT (on TCH/F)

C10818 Handover attempt due to large TA (on TCH/F)

C10819 Handover attempt due to MSC request (on TCH/F)

C10820 Handover attempt due to traffic (on TCH/F)

C10821 Handover attempt due to any other reason (on TCH/F)

C10822 Handover attempt due to uplink received strength (on TCH/H)

C10823 Handover attempt due to downlink received strength (on TCH/H)

C10824 Handover attempt due to uplink interference (on TCH/H)

C10825 Handover attempt due to downlink interference (on TCH/H)

C10826 Handover attempt due to C/I RATIO (on TCH/H)

C10827 Handover attempt due to PBGT (on TCH/H)

C10828 Handover attempt due to large TA (on TCH/H)

C10829 Handover attempt due to MSC request (on TCH/H)

C10830 Handover attempt due to traffic (on TCH/H)

C10831 Handover attempt due to any other reason (on TCH/H)

C10832 Handover attempt due to increased TA in extension cell (on TCH/F)

C10833 Handover attempt due to decreased TA in extension cell (on TCH/F)

C10834 Handover attempt due to uplink quality (on SDCCH)

C10835 Handover attempt due to downlink quality (on SDCCH)

C10836 Handover attempt due to uplink quality (on TCH/F)

C10837 Handover attempt due to downlink quality (on TCH/F)

C10838 Handover attempt due to a good standard level in 3G adjacent cell (on TCH/F)

C10839 Handover attempt due to uplink quality (on TCH/H)

C10840 Handover attempt due to downlink quality (on TCH/H)

C10841 Handover attempt due to good standard level in 3G adjacent cell (on TCH/H)

C10842 Handover attempt due to increased TA in extension cell (on TCH/H)

C10843 Handover attempt due to decreased TA in extension cell (on TCH/H)

C10844 Number of forced transfer handover attempts

C10845 Number of forced handovers during assignment

C10846 Number of forced handovers during handover

Page 193: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 177

Handover Cause Counters Explanation C10801 Definition

Handover attempts due to direct retry

Description

C10801 represents number of handover attempts due to directed retry. In this case, handovers are intra-BSC inter cell and external handover. C10802 triggers due to the DIRECTED RETRY in serving cell when serving cell has congestion during assignments.

Measurement Point

During intra-BSC inter-cell handover, C10802 increments when serving cell sends RADIO APPLY message due to DIRECT RETRY. Similarly, during external, C10802 increments when serving cell sends HANDOVER REQUIRED due to DIRECT RETRY.

C10802 Definition

Handover attempt due to uplink receive strength (on SDCCH)

Description

C10802 represents numbers of handovers due to uplink receive strength. Counter records for both internal and external handovers. C10802 triggers due to uplink received strength on SDCCH of the serving cell.

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10802 increments when serving cell sends RADIO APPLY message due to uplink receiving strength. Similarly, during external handover (intra-BSC) C10802 increments when serving cell sends HANDOVER REQUIRED due to uplink receiving strength.

C10803 Definition

Handover attempt due to downlink receive strength (on SDCCH)

Description

C10803 represents numbers of number of handover attempts due to downlink receive strength. Counter records for both internal and external handovers.

Page 194: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

178 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), counter C10803 increments when serving cell sends RADIO APPLY message due to down link receiving strength. Similarly, during external handover, C10803 increments when the serving cell sends HANDOVER REQUIRED due to down link receiving strength.

C10804 Definition

Handover attempt due to uplink interference (on SDCCH)

Description

C10804 represents number of handovers due to uplink interference. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10804 increments when serving cell sends RADIO APPLY message due to uplink interference. Similarly, during external handover, C10804 increments when serving cell sends HANDOVER REQUIRED due to uplink interference.

C10805 Definition

Handover attempt due to downlink interference (on SDCCH)

Description

C10805 represents number of handovers due to downlink interference. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10805 increments when serving cell sends RADIO APPLY message due to downlink interference. Similarly, during external handover, C10805 increments when serving cell sends HANDOVER REQUIRED due to downlink interference.

C10806 Definition

Handover attempt due to C/I RATIO (on SDCCH)

Description

C10806 represents number of handovers due to C/I RATIO on SDCCH. Counter records for both internal and external handovers.

Page 195: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 179

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10806 increments when serving cell sends RADIO APPLY message due to C/I RATIO. Similarly, during external handover, C10806 increments when serving cell sends HANDOVER REQUIRED due to C/I ratio.

C10807 Definition

Handover attempt due to PBGT (on SDCCH)

Description

C10807 represents number of handovers due to PBGT on SDCCH. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10807 increments when serving cell sends RADIO APPLY message due to PBGT. Similarly, during external handover, C10807 increments when serving cell sends HANDOVER REQUIRED due to PBGT.

C10808 Definition

Handover attempt due to large TA (on SDCCH)

Description

C10808 represents number of handovers due to large TA on SDCCH. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10808 increments when source cell sends RADIO APPLY message due to large TA. Similarly, during external handover, C10808 increments when source cell sends HANDOVER REQUIRED due to large TA.

C10809 Definition

Handover attempt due to MSC request (on SDCCH)

Description

C10809 represents number of handovers due to MSC request on SDCCH. Counter records for both internal and external handovers.

Measurement Point

C10809 increments when serving cell receive HANDOVER ENQUERY message from MSC and sends HANDOVER REQUIRED message to MSC.

Page 196: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

180 Confidential and Proprietary Information of ZTE CORPORATION

C10810 Definition

Handover attempt due to traffic (on SDCCH)

Description

C10810 represents number of handovers due to traffic overload on SDCCH. Counter records for both internal and external handovers.

Measurement Point

Database makes a judgment based on utilizations of serving cell resources and the cell sets threshold. If the traffic exceeds the threshold, BSC sends a message that indicates that cell service is overloaded.

During inter-cell handover, C10810 increments when source cell receives message that indicates that cell service is overloaded and it sends RADIO APPLY message.

Similarly, during handover out C10810 increments when source cell receives message that indicates that cell service is overloaded and it sends HANDOVER REQUIRED.

C10811 Definition

Handover attempt due to any other cause

Description

Counter C10811 represents number of handovers on SDCCH of serving cell due to causes other than above-mentioned causes. Other causes such as fast movement of MS, feeding dips or handover fill-in abnormal. Counter records for both internal and external handovers.

Measurement Point

C10811 increments when serving cell sends Radio Apply message to BSC during intra-cell handover and inter-cell handover on SDCCH in BSC. Similarly, the C10811 increments when serving cell sends HANDOVER REQUIRED message during external handover on SDCCH due to other causes.

C10812 Definition

Handover attempt due to uplink received signal strength

Description

C10812 represents number of handovers due to uplink received signal strength on TCH/F. Counter records for both internal and external handovers. C10812 triggers due to uplink received strength on TCH/F channel of serving cell.

Page 197: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 181

Measurement Point

During intra-cell and inter-cell handover, C10812 increments when serving cell sends RADIO APPLY message due to uplink receiving strength. Similarly, during external handover, C10812 increments when serving cell sends HANDOVER REQUIRED due to uplink receiving strength.

C10813 Definition

Handover attempt due to downlink received signal strength

Description

C10813 represents number of handovers due to downlink received signal strength on TCH/F in serving cell. Counter records for both internal and external handovers. C10813 triggers due to downlink received signal strength on TCH/F channel of serving cell.

Measurement Point

During intra-cell and inter-cell handover, counter C10813 increments when serving cell sends RADIO APPLY message due to downlink receive strength. Similarly, during external handover C10813 increments when serving cell sends HANDOVER REQUIRED due to downlink received signal strength.

C10814 Definition

Handover attempt due to uplink interference

Description

Counter C10814 represents number of handovers due to uplink interference on TCH/F of serving cell. Counter records for both internal and external handovers..

Measurement Point

During intra-cell and inter-cell handover, C10814 increments when serving cell sends RADIO APPLY message due to uplink interference on TCH/F. Similarly, during external handover C10814 increments when serving cell sends HANDOVER REQUIRED due to uplink interference on TCH/F.

C10815 Definition

Handover attempt due to downlink interference

Page 198: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

182 Confidential and Proprietary Information of ZTE CORPORATION

Description

C10815 represents number of handovers due to downlink interference on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10815 increments when serving cell sends RADIO APPLY message due to downlink interference on TCH/F. Similarly, during external handover C10815 increments when serving cell sends HANDOVER REQUIRED due to downlink interference on TCH/F.

C10816 Definition

Handover attempt due to C/I RATIO

Description

C10816 represents number of handovers due to C/I RATIO on TCH/F of serving cell. Counter records for both internal and external handovers..

Measurement Point

During intra-cell and inter-cell handover, C10816 increments when serving cell sends RADIO APPLY message due to C/I RATIO on TCH/F. Similarly, during external handover C10816 increments when serving cell sends HANDOVER REQUIRED due to C/I RATIO on TCH/F.

C10817 Definition

Handover attempt due to PBGT

Description

C10817 represents number of handovers due to PBGT on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10817 increments when serving cell sends RADIO APPLY message due to PBGT on TCH/F. Similarly, during external handover C10817 increments when serving cell sends HANDOVER REQUIRED due to PBGT on TCH/F.

C10818 Definition

Handover attempt due to large TA

Page 199: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 183

Description

C10818 represents number of handovers due to large TA on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10818 increments when serving cell sends RADIO APPLY message due to large TA on TCH/F. Similarly, during external handover C10818 increments when serving cell sends HANDOVER REQUIRED due to large TA on TCH/F.

C10819 Definition

Handover attempt due to MSC request

Description

C10819 represents number of handovers due to MSC request on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

C10819 increments when serving cell receive HANDOVER ENQUERY message from MSC and sends HANDOVER REQUIRED message to MSC.

C10820 Definition

Handover attempt due to traffic over load

Description

C10820 represents number of handovers due to traffic overload on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

Database makes a judgment based on utilizations of serving cell resources and the cell sets threshold. If the traffic exceeds the threshold, BSC sends a message that indicates that cell service is overloaded.

During inter-cell handover, C10820 increments when source cell receives message that indicates that cell service is overloaded and it sends RADIO APPLY message.

Similarly, during handover out C10820 increments when source cell receives message that indicates that cell service is overloaded and it sends HANDOVER REQUIRED.

Page 200: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

184 Confidential and Proprietary Information of ZTE CORPORATION

C10821 Definition

Handover attempt due to any other cause

Description

C10821 represents number of handovers on TCH/F channel of serving cell due to causes other than the above. Other causes are fast movement of MS, feeding dips or handover fill-in abnormal. Counter records for both internal and external handovers.

Measurement Point

C10821 increments when serving cell sends Radio Apply message to BSC during intra-cell handover and inter-cell handover on TCH/F channel in BSC. Similarly C10821 increments when serving cell sends HANDOVER REQUIRED message during external handover on TCH/F due to other causes.

C10822 Definition

Handover attempt due to uplink received signal strength

Description

C10822 represents number of handovers due to uplink received signal strength on TCH/H. Counter records for both internal and external handovers. C10822 triggers due to uplink received signal strength on the TCH/H of serving cell.

Measurement Point

During intra-cell and inter-cell handover, C10822 increments when serving cell sends RADIO APPLY message due to uplink receiving strength.

Similarly, during external handover C10822 increments when serving cell sends HANDOVER REQUIRED due to uplink receiving strength.

C10823 Definition

Handover attempt due to downlink received strength

Description

C10823 represents number of handovers due to downlink received signal strength on TCH/H in serving cell. C10823 triggers due to downlink received strength on the TCH/H of serving cell

Measurement Point

During intra-cell and inter-cell handover, C10823 increments when serving cell sends RADIO APPLY message due to downlink receive

Page 201: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 185

strength. Similarly, during external handover C10823 increments when serving cell sends HANDOVER REQUIRED due to downlink receive strength.

C10824 Definition

Handover attempt due to uplink interference

Description

Counter C10824 represents number of handovers due to uplink interference on TCH/H of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, counter C10824 increments when serving cell sends RADIO APPLY message due to uplink interference on TCH/H. Similarly, during external handover C10824 increments when serving cell sends HANDOVER REQUIRED due to uplink interference on TCH/H.

C10825 Definition

Handover attempt due to downlink interference

Description

C10825 represents number of handovers due to downlink interference on TCH/H of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10825 increments when serving cell sends RADIO APPLY message due to downlink interference on TCH/F. Similarly, during external handover C10825 increments when serving cell sends HANDOVER REQUIRED due to downlink interference on TCH/F

C10826 Definition

Handover attempt due to C/I RATIO

Description

C10826 represents number of handover attempts due to C/I RATIO on TCH/H of serving cell. Counter records for both internal and external handovers.

Page 202: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

186 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

During intra-cell and inter-cell handover, C10826 increments when serving cell sends RADIO APPLY message due to C/I RATIO on TCH/H. Similarly, during external handover C10826 incremented when source cell sends HANDOVER REQUIRED due to C/I RATIO on TCH/H.

C10827 Definition

Handover attempt due to PBGT

Description

C10827 represents number of handovers due to PBGT on TCH/H of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10827 increments when serving cell sends RADIO APPLY message due to PBGT on TCH/H. Similarly, during external handover C10827 increments when serving cell sends HANDOVER REQUIRED due to PBGT on TCH/H.

C10828 Definition

Handover attempt due to large TA

Description

C10828 represents number of handovers due to large TA on TCH/F of serving cell. Counter records for both internal and external handovers..

Measurement Point

During intra-cell and inter-cell handover, C10828 increments to count when serving cell sends RADIO APPLY message due to large TA on TCH/H. Similarly, during external handover the counter C10828 increments to count when serving cell sends HANDOVER REQUIRED due to large TA on TCH/H.

C10829 Definition

Handover attempt due to MSC request

Description

C10829 represents number of handovers due to MSC request on TCH/H of serving cell. Counter records for both internal and external handovers.

Page 203: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 187

Measurement Point

C10829 increments when serving cell receive HANDOVER ENQUERY message from MSC and sends HANDOVER REQUIRED message.

C10830 Definition

Handover attempt due to traffic

Description

C10830 represents number of handovers due to traffic overload on TCH/H of serving cell. Counter records for both internal and external handovers.

Measurement Point

Database makes a judgment based on utilizations of serving cell resources and the cell sets threshold. If the traffic exceeds the threshold, BSC sends a message that indicates that cell service is overloaded.

During inter-cell handover, C10830 increments when source cell receives message that indicates that cell service is overloaded and it sends RADIO APPLY message.

Similarly, during handover out C10830 increments when source cell receives message that indicates that cell service is overloaded and it sends HANDOVER REQUIRED.

C10831 Definition

Handover attempt due to any other cause

Description

C10831 represents number of handovers on TCH/H of serving cell due to other than above-mentioned causes. Other causes are fast movement of MS, feeding dips or handover fill-in abnormal. Counter records for both internal and external handovers.

Measurement Point

C10831 increments when serving cell sends Radio Apply message to BSC during intra-cell handover and inter-cell handover on TCH/H in BSC. Similarly counter C10831 increments when serving cell sends HANDOVER REQUIRED message during external handover on TCH/H due to other causes.

C10832 Definition

Handover attempt due to increase in TA in extension cell (on TCH/F)

Page 204: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

188 Confidential and Proprietary Information of ZTE CORPORATION

Description

C10832 represents number of intra-cell intra-BSC and intra-BSC inter-cell handovers due to large TA on TCH/F channel in current extension cell. Initially subscriber is on TCH/F of common cell TRX. If TA value is too high, BSC handovers subscriber from common cell TRX to extension cell TRX.

Measurement Point

C10832 increments when common cell sends RADI APPLY message due to increased TA on TCH/F.

C10833 Definition

Handover attempt due to decreased TA in extension cell (on TCH/F)

Description

C10833 represents number of intra-cell and inter-cell handovers due to decrease in TA on TCH/F channel of current extension cell. Initially subscriber is in TCH/F channel of extension cell TRX. If TA value decreases, BSC handovers subscriber from extension cell TRX to common cell TRX.

Measurement Point

C10833 increments when extension cell sends RADI APPLY message due to increased TA on TCH/F.

C10834 Definition

Handover attempt due to uplink quality (on SDCCH)

Description

Counter C10834 represents number of handover attempts due to uplink quality on SDCCH of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10834 increments when serving cell sends RADIO APPLY message due to uplink quality. Similarly, during external handover C10834 increments when serving cell sends HANDOVER REQUIRED due to uplink quality.

C10835 Definition

Handover attempt due to downlink quality (on SDCCH)

Page 205: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 189

Description

Counter C10835 represents number of handover attempts due to downlink quality on SDCCH of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10834 increments when serving cell sends RADIO APPLY message due to downlink quality. Similarly, during external handover C10834 increments when serving cell sends HANDOVER REQUIRED due to downlink quality.

C10836 Definition

Handover attempt due to uplink quality (on TCH/F)

Description

C10836 represents number of handover attempts due to uplink quality on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10836 increments when serving cell sends RADIO APPLY message due to uplink quality of TCH/F. Similarly, during external handover C10836 increments when serving cell sends HANDOVER REQUIRED due to uplink quality of TCH/F.

C10837 Definition

Handover attempt due to downlink quality (on TCH/F)

Description

C10837 represents number of handover attempts due to downlink quality on TCH/F of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover, C10837 increments when serving cell sends RADIO APPLY message due to downlink quality of TCH/F. Similarly, during external handover C10837 increments when serving cell sends HANDOVER REQUIRED due to downlink quality of TCH/F.

Page 206: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

190 Confidential and Proprietary Information of ZTE CORPORATION

C10838 Definition

Number of handover attempts due to a good standard level of TCH/F in 3G adjacent cell (ON TCH/F)

Description

C10838 represents number of handovers due to good signal strength of TCH/F in 3G adjacent cells. In this case, handover is out of BSC between BSC and RNC.

Measurement Point

C10838 increments when serving cell sends HANDOVER REQUIRED due to good signal strength of TCH/F in 3G adjacent cell.

C10839 Definition

Handover attempt due to uplink quality (on TCH/H)

Description

C10839 represents number of handover attempts due to uplink quality on TCH/H of serving cell. Counter records for both internal and external handovers..

Measurement Point

During intra-cell and inter-cell handover, counter C10839 increments when serving cell sends RADIO APPLY message due to uplink quality of TCH/H. Similarly, during external handover C10839 increments when serving cell sends HANDOVER REQUIRED due to uplink quality of TCH/H.

C10840 Definition

Handover attempt due to downlink quality (on TCH/H)

Description

C10840 represents number of handover attempts due to downlink quality on TCH/H of serving cell. Counter records for both internal and external handovers.

Measurement Point

During intra-cell and inter-cell handover counter C10840 increments when serving cell sends RADIO APPLY message due to downlink quality of TCH/H. Similarly, during external handover C10840 increments when serving cell sends HANDOVER REQUIRED due to downlink quality of TCH/H.

Page 207: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 10 - Handover Cause Measurement

Confidential and Proprietary Information of ZTE CORPORATION 191

C10841 Definition

Handover attempt due to a good standard level of TCH/H in 3G adjacent cell (ON TCH/H)

Description

C10841 represents number of handover due to good signal strength of TCH/H in 3G adjacent cells. In this case, handover is out of BSC between BSC and RNC.

Measurement Point

C10841 increments when serving cell sends HANDOVER REQUIRED due to good signal strength of TCH/F in 3G adjacent cell.

C10842 Definition

Handover attempt due to increased TA in extension cell (on TCH/H)

Description

C10842 represents number of intra-cell and inter-cell handovers due to increase in TA on TCH/H of current extension cell. Initially subscriber is on TCH/H of TRX of common cell. If TA value is too high, BSC handovers subscriber from common cell TRX to extension cell TRX.

Measurement Point

C10842 increments when common cell sends RADIO APPLY message to BSC due to increased TA.

C10843 Definition

Handover attempt due to decreased TA in extension cell (on TCH/H)

Description

C10843 represents number of intra-cell and inter-cell handovers due to decrease in TA on TCH/H of current extension cell. Initially subscriber is on TCH/H of common cell TRX. If TA value is too low, BSC handovers subscriber from extension cell TRX to common cell TRX.

Measurement Point

C10843 increments when extension cell sends RADIO APPLY message to BSC due to decreased TA

Page 208: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

192 Confidential and Proprietary Information of ZTE CORPORATION

C10844 Definition

Number of forced transfer handover attempts

Description

BSC can not handover users of a cell to other neighboring cell due to downlink path loss and low TA value. This situation creates congestion. When BSC allows forced transfer, BSC forcedly handover users of a cell to other neighboring cell to avoid possible congestion.

Measurement Point

C10844 increments when condition for force transfer of a handover satisfies in a cell and BTS sends RADIO APPLY message to BSC.

C10845 Definition

Number of forced handovers during assignment

Description

BSC can not handover the users in a cell to other neighboring cell due to downlink path loss and low TA value. This situation creates congestion. When BSC allows forced transfer, BSC forcefully handover users of a cell to other neighboring cell to avoid possible congestion.

Measurement Point

C10846 Definition

Number of forced handovers during handover

Description

If parameter configuration allows forced handover in and there are rescue handover requests from high priority subscribers, or, there are external handover in or handover requests indicating pre-empt of channels but no channels available in the object cell, in such a case, a low priority subscriber who has seize channel will be found and be switched to adjacent cell, the released channel will be assigned to the high priority subscriber

Measurement Point

A low priority subscriber, who has seized channel, has been found in handover. Counter increments when the ‘ForcedHoApply’ message is sent to the subscriber.

Page 209: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 193

C h a p t e r 11

General Handover Measurement

This chapter covers the following topics:

Handover Counters

Handover Counters General Handover measurement involves handover counters that provide statistics for handover processes that arises from all types of handover causes. These counters show handover success ratio, number of handover attempts, execution, success and failure. This chapter analyzes handover in aspect of the control entity and provides statistics for both the executions and handover successes. These counters show statistics for request, success and failure of intra-cell handover, intra-BSC inter-cell handover and intra-MSC handover.

Table 19 lists all the handover counters.

TAB L E 19 H AN D O V E R C O U N T E R S

Counter No. Counter Definition

C10901 Number of Intra-BSC inter-cell handover outs

C10902 Number of Intra-BSC inter-cell handover out executions

C10903 Number of successful Intra-BSC inter-cell handover outs

C10904 Number of MSC-controlled handover out attempts

C10905 Number of number of MSC-controlled handover out request failures due to unclear causes

C10906 Number of MSC-controlled handover out request failures due to unavailable ground resource

C10907 Number of MSC-controlled handover out requests failures due to unavailable wireless resource

Page 210: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

194 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C10908 Number of MSC-controlled handover out request failures due to other causes

C10909 Number of MSC-controlled handover out executions

C10910 Number of successful MSC-controlled handover outs

C10911 Number of Intra-BSC inter-cell handover in attempts

C10912 Number of Intra-BSC inter-cell handover in attempts

C10913 Number of successful Intra-BSC inter-cell handover ins

C10914 Number of Intra-BSC handover in attempts

C10915 Number of MSC-controlled handover in attempts for general handover

C10916 Number of MSC-controlled handover ins due to forced-release attempt

C10917 Number of MSC-controlled handover in attempts due to forced release

C10918 Number of MSC-controlled handover ins due to queue attempts

C10919 Number of MSC-controlled handover ins attempts due to queue

C10920 Number of successful MSC-controlled handover ins

C10921 Number of MSC-controlled total handover ins due to queue

C10922 Number of MSC-controlled handover ins due to queues

C10923 Number of successful MSC-controlled total handover ins due to queue

C10924 Number of MSC-controlled successful handover ins due to queues

C10925 Number of handover in attempts from the same layer and same frequency

C10926 Number of successful handover ins from the same layer and same frequency

C10927 Number of handover in attempts to the same layer and same frequency

C10928 Number of successful handover ins to the same layer and same frequency

C10929 Number of handover in attempts from undefined layer and to the same frequency

C10930 Number of successful handover ins from undefined layer and to the same frequency

C10931 Number of handover in attempts to undefined layer and same frequency

C10932 Number of successful handover out to undefined layer and same frequency

C10933 Number of incoming handover attempts from undefined layer GSM900 to current layer GSM1800

C10934 Number of handover in executions from undefined layer (GSM900) to current layer (GSM1800)

C10935 Number of successful handover ins from undefined layer (GSM900) to current layer (GSM1800 )

C10936 Number of handover out attempts from undefined layer (GSM900) to current layer (GSM1800z)

Page 211: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 195

Counter No. Counter Definition

C10937 Number of successful handover outs from undefined layer (GSM900) to current layer (GSM1800z)

C10938 Number of handover in attempts from undefined layer (GSM1800) to current layer (GSM900)

C10939 Number of handover in attempts from undefined layer (GSM1800) to current layer (GSM900)

C10940 Number of successful handover ins from undefined layer (GSM1800) to current layer (GSM900)

C10941 Number of handover out attempts from undefined layer (GSM1800) to current layer (GSM900)

C10942 Number of successful handover outs to undefined layer (GSM1800) to current layer (GSM900)

C10943 Number of handover in attempts from upper layer and same frequency

C10944 Number of successful handover ins from upper layer and same frequency

C10945 Number of handover out attempts to upper layer and same frequency

C10946 Number of successful handover outs to upper layer and same frequency

C10947 Number of handover in attempts from lower layer and same frequency

C10948 Number of successful handover in from lower layer and same frequency

C10949 Number of handover out attempts to lower layer and same frequency

C10950 Number of successful handover out to lower layer and same frequency

C10951 Number of handover in attempts at same layer and from GSM900 to GSM1800

C10952 Number of handover in attempts at same layer and from GSM900 to GSM1800

C10953 Number of successful handover ins at same layer and from GSM900 to GSM1800

C10954 Number of handover-out attempt to same layer and from GSM900 to GSM1800

C10955 Number of successful handover out to same layer and from GSM900 to GSM1800

C10956 Number of handover in attempts at upper layer and from GSM900 to GSM1800

C10957 Number of handover in attempts at upper layer and from GSM900 to GSM1800

C10958 Number of successful handover ins at upper layer and from GSM900 to GSM1800

C10959 Number of handover out attempts to upper layer and from GSM900 to GSM1800

C10960 Number of successful handover outs to upper layer and from GSM900 to GSM1800

C10961 Number of handover in attempt at lower layer and from GSM900 to GSM1800

C10962 Number of handover in attempts at lower layer and from GSM900 to

Page 212: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

196 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

GSM1800

C10963 Number of handover in at lower layer and from GSM900 to GSM1800

C10964 Number of successful handover out attempts to lower layer and from GSM900 to GSM1800

C10965 Number of successful handover out to the lower layer and from GSM900 to GSM1800

C10966 Number of handover in attempts at same layer and from GSM1800 to GSM900

C10967 Number of handover in attempts at same layer and from GSM1800 to GSM900

C10968 Number of successful handover in from same layer and from GSM1800 to GSM900

C10969 Number of handover out attempts to same layer and from GSM1800 to GSM900

C10970 Number of successful handover out to same layer and from GSM1800 to GSM900

C10971 Number of handover in attempts at upper layer and from GSM1800 to GSM900

C10972 Number of handover in attempts at upper layer and from GSM1800 to GSM900

C10973 Number of successful handover ins at upper layer and different frequencies (1800 MHz → 900 MHz)

C10974 Number of handover out attempts to upper layer and from GSM1800 to GSM900

C10975 Number of successful Handover-out to the upper layer and from GSM1800 to GSM900

C10976 Number of handover in attempts at lower layer and from GSM1800 to GSM900

C10977 Number of handover in attempts at lower layer and from GSM1800 to GSM900

C10978 Number of successful handover in at lower layer and from GSM1800 to GSM900

C10979 Number of handover out attempts to lower layer and from GSM1800 to GSM900

C10980 Number of successful handover outs to lower layer and from GSM1800 to GSM900

C10981 Number of intra-cell handover attempts

C10982 Number of intra-cell successful handovers

C10983 Number of intra-cell inner-circle-to-outer-circle handover attempts

C10984 Number of intra-cell successful inner-circle-to-outer-circle handovers

C10985 Number of intra-cell outer-circle-to-inner-circle handover attempts

C10986 Number of successful intra-cell outer-circle-to-inner-circle handovers

C10987 Number of intra-cell inner-circle-to-inner-circle handover attempts

C10988 Number of successful intra-cell inner-circle-to-inner-circle handovers

Page 213: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 197

Counter No. Counter Definition

C10989 Number of intra-cell outer-circle-to-outer-circle handover attempts

C10990 Number of successful intra-cell successful outer-circle-to-outer-circle handovers

C10991 Number of handover out executions from GSM1800 to GSM900

C10992 Number of handover out executions from GSM900 to GSM1800

C10993 Number of 2G to 3G handover attempts

C10994 Number of 2G to 3G handover executions

C10995 Number of successful 2G to 3G handovers

C10996 Number of 3G to 2G handover attempts

C10997 Number of 3G to 2G handover executions

C10998 Number of successful 3G to 2G handovers

C10999 Number of intra-cell handover attempts from TCH/F

C109100 Number of intra-cell TCH/F-to-TCH/F handover executions

C109101 Number of successful intra-cell TCH/F-to-TCH/F handovers

C109102 Number of intra-cell TCH/F-to-TCH/H handover executions

C109103 Number of successful intra-cell TCH/F-to-TCH/H handover

C109104 Number of intra-cell handover attempts from TCH/H

C109105 Number of intra-cell TCH/H-to-TCH/F handover executions

C109106 Number of successful intra-cell TCH/H-to-TCH/F handover

C109107 Number of intra-cell TCH/H-to-TCH/H handover executions

C109108 Number of successful intra-cell TCH/H-to-TCH/H handover

C109109 Number of inter-cell handover attempts times from TCH/F

C109110 Number of inter-cell TCH/F-to-TCH/F handover executions

C109111 Number of successful inter-cell TCH/F-to-TCH/F handovers

C109112 Number of inter-cell TCH/F-to-TCH/H handover executions

C109113 Number of successful inter-cell TCH/F-to-TCH/H handovers

C109114 Number of inter-cell handover attempts from TCH/H

C109115 Number of inter-cell TCH/H-to-TCH/F handover executions

C109116 Number of successful inter-cell TCH/H-to-TCH/F handovers

C109117 Number of inter-cell TCH/H-to-TCH/H handover executions

C109118 Number of successful inter-cell TCH/H-to-TCH/H handovers

C109119 Number of double-frequency external handover-out attempts

C109120 Number of double-frequency external handover-out executions

C109121 Number of successful double-frequency external handover outs

C109122 Number of double-frequency external handover in attempts

C109123 Number of double-frequency external handover in attempts

C109124 Number of successful double-frequency external handover ins

Page 214: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

198 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C109125 Number of intra-cell invalid handovers

C109126 Intra-BSC handover-in forced release attempts

C109127 Intra-BSC handover-in executions (forced release)

C109128 Intra-BSC handover-in queue attempts

C109129 Intra-BSC handover-in executions (queue)

Handover Counters Explanation C10901 Definition

Number of Intra-BSC inter-cell handover outs

Description

C10901 represents number of Intra-BSC inter-cell handover outs. Initially MS in serving cell sends power measurement report to BTS of serving cell. BTS of serving cell analyze the power measurement report, makes its average and sends it to BSC of serving cell. BSC of serving cell analyzes the power measurement report according to handover algorithm and sends RADIO APPLY message to BSC of destination cell. At this time, counter C10901 increments.

Measurement Point

Refer point A1 as shown in FIGURE 14.

FIGURE 14 - I N T R A-BSC I N T E R -C E L L H AN D O V E R M E AS U R E M E N T

A1

BSC:Ori_CellBTS:Ori_CellMS

HANDOVER COMMAND

CHANNEL ACT

A2

CHANNEL ACT ACK

HANDOVER COMPLETE

BTS:Des_Cell

HANDOVER COMMAND

Measurement ReportHandover Algorithm

A3

BSC:Des_Cell

RADIO APPLY

RADIO AVAIL

HANDOVER COMPLETE

Measurement Report

HANDOVER COMPLETE

A4

A5

A6

Page 215: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 199

C10902 Definition

Number of Intra-BSC inter-cell handover out executions

Description

C10902 represents number of actual Intra-BSC inter-cell handover out executions. Initially BSC of serving cell analyzes power measurement report according to handover algorithm and it sends RADIO APPLY message to BSC of destination cell. Then the BSC of destination cell checks radio resource availability and sends CHANNEL ACT message to the BTS of destination cell. If BTS of destination cell has radio channel available then it sends CHANNEL ACT ACK message to BSC of destination cell. At last, BSC of destination cell sends RADIO AVAIL message to BSC of serving cell. C10902 increments if BSC of serving cell receive RADIO AVAIL message from BSC of destination cell.

Measurement Point

Refer point A2, as shown in FIGURE 14.

C10903 Definition

Number of successful Intra-BSC inter-cell handover outs

Description

C10903 represents number of successful Intra-BSC inter-cell handover outs. Initially BSC of serving cell sends HANDOVER COMMAND to BTS of destination cell. Then BTS of serving cell sends HANDOVER COMMAND to MS in serving cell. MS of serving cell sends HANDOVER COMPLETE message to BTS of destination cell. BTS of destination cell sends HANDOVER COMPLETE message to BSC of destination cell. BSC of destination cell receives HANDOVER COMPLETE message at this, C10903 increments.

Measurement Point

Counter C10903 makes statistics at point A3, as shown in FIGURE 14.

C10904 Definition

Number of Intra-MSC out going Handover attempts

Description

C10904 represents number of Intra-MSC handover-out attempts, when BSC sends HANDOVER REQUIRED message to MSC.

Page 216: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

200 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 15 - I N T R A M S C H AN D O V E R S U C C E S S E S

A1

BSCMS MSC

HANDOVER REQUIRED

A3

HANDOVER COMMANDHANDOVER COMMAND

CLEAR COMMAND

A2

FIGURE 16 - I N T R A M S C H AN D O V E R F AI L

A1

BSC MSC

HANDOVER REQUIRED

HANDOVER REQUIRED REJECT

A2,B1,C1,D1

T7 TimeOut

Measurement Point

C10904 makes statistics at point A1, as shown in FIGURE 15 and FIGURE 16.

C10905 Definition

Number of Intra-MSC out going handover request failures due to unclear causes

Description

C10905 represents number of Intra-MSC out going handover attempts failure due to unknown causes. Initially BSC of serving cell sends HANDOVER REQUIRED request to MSC. If timer T7 expires due to unclear causes, the MSC sends HANDOVER REQUIRED REJECTED command to the BSC of serving cell. BSC of serving cell receives HANDOVER REQUIRED REJECTED message from MSC.

Measurement Point

Refer point A2 as shown in FIGURE 16.

Page 217: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 201

C10906 Definition

Number of Intra-MSC out going handover requests failure due to unavailability due to ground resource

Description

C10906 represents number of Intra-MSC out going handover attempts failure due to unavailable ground resource in serving cell. Initially BSC of serving cell sends HANDOVER REQUIRED request to MSC. Due to unavailability of ground resource, MSC sends HANDOVER REQUIRED REJECTED message to the BSC of serving cell. BSC of serving cell receives HANDOVER REQUIRED REJECTED message from MSC. At this time, MSC-controlled out going handover requests fail and C10906 increments.

Measurement Point

Refer point B1, as shown in FIGURE 16.

C10907 Definition

Number of Intra-MSC out going Handover requests failure due to unavailability of wireless resource

Description

C10907 represents number of Intra-MSC out going handover attempts failure due to unavailability of wireless resource. Initially BSC of serving cell sends HANDOVER REQUIRED request to MSC. Due to unavailability of wireless resource, MSC sends HANDOVER REQUIRED REJECTED message to the BSC of serving cell. BSC of serving cell receives HANDOVER REQUIRED REJECTED message from MSC. At this time, MSC-controlled handover-out request fails and counter C10907 increments.

Measurement Point

Refer point C1, as shown in FIGURE 16.

C10908 Definition

Number of Intra-MSC out going handover requests failure due to other causes

Description

C10908 represents number of Intra-MSC out going handover attempts failure due to other causes. These other causes are other than the above-mentioned causes. Initially BSC of serving cell sends HANDOVER

Page 218: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

202 Confidential and Proprietary Information of ZTE CORPORATION

REQUIRED request to MSC. Due to other causes, MSC sends HANDOVER REQUIRED REJECTED message to the BSC of serving cell. BSC of serving cell receives HANDOVER REQUIRED REJECTED message from MSC. At this time, MSC-controlled out going handover requests fails and C10908 increments.

Measurement Point

Refer point D1, as shown in FIGURE 16.

C10909 Definition

Number of Intra-MSC out going handover executions

Description

C10909 represents number of Intra-MSC actual out going handover executions. Initially BSC of serving cell sends HANDOVER REQUIRED request to MSC. Then MSC sends HANDOVER COMMAND message to BSC of serving cell. BSC sends HANDOVER COMMAND message to MS of serving cell.

Measurement Point

Refer point A2, as shown in FIGURE 15

C10910 Definition

Number of successful Intra-MSC out going handovers

Description

C10910 represents number of Intra-MSC out going handover success. Initially BSC of serving cell sends HANDOVER REQUIED message to MSC. Then MSC sends HANDOVER COMMAND message to current BSC as reply. BSC of serving cell sends HANDOVER COMMAND message to MS in serving cell. After successful completion of handover, MSC sends CLEAR command to BSC in serving cell. C10910 increments, when BSC of serving cell receives CLEAR COMMAND message.

Measurement Point

Refer point A3 as shown in FIGURE 15.

C10911 Definition

Number of Intra-BSC Inter-cell handover in attempts

Description

C10911 represents number of successful Intra-BSC handover-ins among Intra-BSC inter-cell handover. Initially MS of serving cell sends

Page 219: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 203

power measurement report to BTS of serving cell. BTS of serving cell makes average of power measurement and send this report to BSC of serving cell. Here BSC of serving cell analyze power measurement according to handover algorithm. If BSC of serving cell decides to handover serving cell MS to destination cell, the BSC of serving cell sends RADIO APPLY message to BSC of destination cell. C10911 increments, when BSC of destination cell receives RADIO APPLY message.

Measurement Point

Refer point A4 as shown in FIGURE 14.

C10912 Definition

Number of Intra-BSC inter-cell handover in attempts

Description

C10912 represents number of Intra-BSC inter-cell handover executions among Intra-BSC inter-cell handover. Initially BSC of serving cell analyzes power measurement report according to handover algorithm and it sends RADIO APPLY message to BSC of destination cell. Then the BSC of destination cell checks radio resource availability and sends CHANNEL ACT message to the BTS of destination cell. If BTS of destination cell has radio channel available then it sends CHANNEL ACT ACK message to BSC of destination cell. At last, BSC of destination cell sends RADIO AVAIL message to BSC of serving cell.

Measurement Point

Refer point A5 as shown in FIGURE 14.

C10913 Definition

Number of successful Intra-BSC inter-cell handover ins

Description

C10913 represents number of handover-in success among Intra-BSC inter-cell handover. Initially BSC of serving cell sends HANDOVER COMMAND to BTS of destination cell. Then BTS of serving cell sends HANDOVER COMMAND to MS in serving cell.

MS of serving cell sends HANDOVER COMPLETE message to BTS of destination cell. BTS of destination cell sends HANDOVER COMPLETE message to BSC of destination cell. BSC of destination cell receives HANDOVER COMPLETE message and sends HANDOVER COMPLETE message as reply to BSC of destination cell.

Measurement Point

Refer point A6 as shown in FIGURE 14.

Page 220: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

204 Confidential and Proprietary Information of ZTE CORPORATION

C10914 Definition

Number of Intra-MSC handover in attempts

Description

C10914 represents number of Intra-MSC external handover in attempts. C10914 increments when BSC of serving cell receives HANDOVER REQUEST message from MSC.

Measurement Point

Refer point A1 as shown in FIGURE 17.

FIGURE 17 - I N T R A MSC H AN D O V E R I N

A1,B1,C1,D1

BSCMS MSC

HANDOVER REQUEST

A3,B3,C3

A2,D2,E2,F2

HANDOVER REQUEST ACK

HANDOVER DETECTHANDOVER COMPLETE

HANDOVER COMPLETE

C10915 Definition

Number of MSC-controlled general handover-in execution

Description

C10915 represents number of Intra-MSC external handover-in executions. C10915 increments when destination cell applies for wireless resource successfully and sends HANDOVER REQUEST ACK message to serving cell.

Measurement Point

Refer point A2 as shown in FIGURE 17.

C10916 Definition

Number of MSC-controlled handover-in attempt by forced-release

Page 221: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 205

Description

C10916 represents number of MSC-controlled external handover-in by forced release. C10916 increments when destination cell receives HANDOVER REQUEST and BSC adopts forced release method to get wireless resource.

Measurement Point

Refer point B1 in FIGURE 17.

C10917 Definition

Number of Intra-MSC handover in attempts by forced release

Description

C10917 represents number of Intra-MSC external handover in attempts by forced release method. C10917 increments when destination cell get wireless resource by forced release.

Measurement Point

Refer point D2 as shown in FIGURE 17.

C10918 Definition

Number of Intra-MSC handover in queue attempts

Description

C10918 represents number of queuing to get resource during Intra-MSC external handover in. BSC makes queue due to unavailable wireless resource. C10918 increments when destination cell receives HANDOVER REQUEST message.

Measurement Point

Refer point C1 as shown in FIGURE 17.

C10919 Definition

Number of queuing executions during Intra-MSC handover in

Description

C10919 represents number of queuing executions during Intra-MSC external handover in to get channel. C10919 increments when target cell gets wireless resource after queuing. It then sends HANDOVER REQUEST ACK to source cell.

Page 222: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

206 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Refer E2 as shown in FIGURE 17.

C10920 Definition

Number of successful Intra-MSC handover in

Description

C10920 represents number of successful Intra-MSC external handover in. C10920 increments when destination cell receives HANDOVER COMPLETE message.

Measurement Point

Refer point A3 as shown in FIGURE 17.

C10921 Definition

Total queue time during incoming Intra-MSC handover

Description

C10921 represents total time used for queuing during Intra-MSC external handover in. Counter increments when BSC obtains wireless resource successfully and queuing expires.

Measurement Point

Refer point D1 as shown in FIGURE 17.

C10922 Definition

Number of queues during Intra-MSC handover in

Description

C10922 represents number of resources obtained by queuing during Intra-MSC external handover in.

Measurement Point

Refer point F2 in FIGURE 17.

C10923 Definition

Total successful queue during Intra-MSC handover in

Page 223: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 207

Description

C10923 represents total time used for successful channel queuing during Intra-MSC external handover in. C10923 increments when destination cell receives HANDOVER COMPLETE message.

Measurement Point

Refer point B3 as shown in FIGURE 17.

C10924 Definition

Number of successful queues during Intra-MSC handover in

Description

C10924 represents number of successful handover when BSC obtains wireless resources by queuing during Intra-MSC external handover-in.

Measurement Point

Refer point C3 as shown in FIGURE 17.

C10925 Definition

Number of handover in attempts from same layer and at the same frequency

Description

C10925 represents number of handover in attempts from same layer and at the same frequency during Intra-BSC inter-cell handover in cell.

Measurement Point

C10925 increments when destination cell receives RADIO APPLY message.

C10926 Definition

Number of successful handover in from same layer and at the same frequency

Description

C10926 represents number of handover in success from same layer and same frequency during Intra-BSC inter-cell handover-in in cell.

Measurement Point

C10926 increments when destination cell receives HANDOVER COMPLETE message.

Page 224: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

208 Confidential and Proprietary Information of ZTE CORPORATION

C10927 Definition

Number of handover out attempts to same layer and at the same frequency

Description

C10927 represents number of handover-out attempt to same layer and at the same frequency during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10927 increments when BSC receives measurement report.

C10928 Definition

Number of handover-out success to same layer and at the same frequency

Description

Counter C10928 represents number of handover-out success to same layer and at the same frequency during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10928 increments when destination cell receives HANDOVER COMPLETE message.

C10929 Definition

Number of handover in attempts from undefined layer and at the same frequency

Description

C10929 represents number of handover in attempts from undefined layer and at the same frequency during Intra-BSC inter-cell handover in a cell.

Measurement Point

C1O929 increments when destination cell receives RADIO APPLY message.

Page 225: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 209

C10930 Definition

Number of successful handover in from undefined layer and at the same frequency

Description

C10930 represents number of handover-in success from undefined layer and same frequency during Intra-BSC inter-cell handover-in in a cell.

Measurement Point

C10930 increments when destination cell receives HANDOVER COMPLETE message.

C10931 Definition

Number of handover out attempts to undefined layer and at the same frequency

Description

C10931 represents number of handover out attempts to undefined layer and at the same frequency during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10931 increments when BSC of serving cell receives measurement report and it sends RADIO APPLY message to destination cell.

C10932 Definition

Number of successful handover out to undefined layer and at the same frequency

Description

C10932 represents number of successful handover out to undefined layer and at the same frequency during Intra-BSC inter-cell handover out in a cell.

Measurement Point

Counter increments when destination cell receives HANDOVER COMPLETE message

Page 226: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

210 Confidential and Proprietary Information of ZTE CORPORATION

C10933 Definition

Number of handover in attempts from undefined layer (GSM 900) to current layer (GSM1800)

Description

C10933 represents number of handover in attempts from undefined layer (GSM900) to current layer (GSM1800) during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10933 increments when destination cell receives RADIO APPLY message.

C10934 Definition

Number of handover in attempts from undefined layer (GSM900) to current layer (GSM1800)

Description

C10934 represents number of handover in attempts from undefined layer (GSM900) to current layer (GSM1800) during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10934 increments when destination cell receives CHL ACTIVE ACK message.

C10935 Definition

Number of successful handover in from undefined layer (GSM900) to current layer (GSM1800)

Description

C10935 represents number of successful handover in from undefined layer (GSM900) to current layer (GSM1800) during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10935 increments when destination cell receives HANDOVER COMPLETE message.

Page 227: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 211

C10936 Definition

Number of handover out attempts from GSM900 to undefined layer (GSM 1800)

Description

C10936 Represents number of out going handover attempts from GSM900 to undefined layer (GSM1800) during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10936 increments when BSC receives measurement report and it sends RADIO APPLY message sends to destination cell.

C10937 Definition

Number of successful handover outs from GSM900 to undefined layer (GSM1800)

Description

C10937 represents number of successful handover outs from GSM900 to undefined layer (GSM1800) during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10937 increments when serving cell receives HANDOVER COMPLETE message.

C10938 Definition

Number of handover in attempts from undefined layer (GSM1800) to current layer (GSM900)

Description

C10939 represents number of handover in attempts from undefined layer (GSM1800) to current layer (GSM900) during Intra-BSC inter-cell handover in a cell.

Measurement Point

Counter increments when destination cell receives RADIO APPLY message.

Page 228: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

212 Confidential and Proprietary Information of ZTE CORPORATION

C10939 Definition

Number of handover in attempts from undefined layer (GSM1800) to current layer (GSM900)

Description

C10939 represents number of handover in attempts from undefined layer (GSM1800) to current layer (GSM900) during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10939 increments when destination cell receives CHL ACTIVE ACK message.

C10940 Definition

Number of successful handover ins from undefined layer (GSM1800) to current layer (GSM900)

Description

C10940 represents number of successful handover in successes from undefined layer (GSM1800) to current layer (GSM900) during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10940 increments when target cell receives HANDOVER COMPLETE message.

C10941 Definition

Number of handover out attempts from GSM1800 to undefined layer (GSM900)

Description

C10941 represents number of handover out attempts from GSM1800 to undefined layer (GSM900) during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10941 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

Page 229: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 213

C10942 Definition

Number of successful handover out success from GSM1800 to undefined layer (GSM1800)

Description

C10942 represents number of successful handover outs from GSM1800 to undefined layer (GSM900) during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10942 increments when serving cell receives HANDOVER COMPLETE message.

C10943 Definition

Number of handover-in attempts from upper layer and at the same frequency

Description

C10943 represents number of handover in attempts from upper layer and at the same frequency during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10943 increments when destination cell receives RADIO APPLY message.

C10944 Definition

Number of successful handover in success from upper layer and at the same frequency

Description

C10944 represents number of successful handover in from upper layer and at the same frequency during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10944 increments when destination cell receives HANDOVER COMPLETE message.

Page 230: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

214 Confidential and Proprietary Information of ZTE CORPORATION

C10945 Definition

Number of handover out attempts to upper layer and same frequency

Description

C10945 represents number of handover out attempts to upper layer and at the same frequency during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10945 makes statistics when BSC receives measurement report and it sends RADIO APPLY message to target cell.

C10946 Definition

Number of successful handover out to upper layer and at the same frequency

Description

C10946 represents number of successful handover outs to upper layer and at the same frequency during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10946 increments when source cell receives HANDOVER COMPLETE message.

C10947 Definition

Number of handover in attempts from lower layer and at the same frequency

Description

C10947 represents number of handover in attempts from the lower layer and at the same frequency during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10947 increments when destination cell receives RADIO APPLY message.

C10948 Definition

Number of successful handover in successes from lower layer and at the same frequency

Page 231: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 215

Description

C10948 represents number of successful handover in from lower layer and at the same frequency during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10948 increments when destination cell receives HANDOVER COMPLETE message.

C10949 Definition

Number of handover out attempts to lower layer and at the same frequency

Description

C10949 represents number of handover out attempts to lower layer and at the same frequency during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10949 increments when BSC receives measurement report and sends RADIO APPLY message to destination cell.

C10950 Definition

Number of successful handover out to lower layer and at the same frequency

Description

C10950 represents number of successful handover out to lower layer and at the same frequency during Intra-BSC inter-cell handover out in a cell.

Measurement Point

Counter C10950 increments when source cell receives HANDOVER COMPLETE message.

C10951 Definition

Number of handover in attempts from same layer and from GSM900 to GSM1800

Description

C10951 represents number of handover in attempts at same layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in a cell.

Page 232: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

216 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C10951 increments when destination cell receives RADIO APPLY message.

C10952 Definition

Number of handover in attempts at same layer and from GSM900 to GSM1800

Description

C10952 represents number of handover in attempts from same layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10953 increments when target cell receives CHL ACTIVE ACK message.

C10953 Definition

Number of successful handover in at same layer and from GSM900 to GSM1800 MHz

Description

C10953 represents number of successful handover in of the same layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10954 increments when destination cell receives HANDOVER COMPLETE message.

C10954 Definition

Number of handover out attempts to same layer and from GSM900 to GSM1800

Description

C10954 represents number of handover out attempts to same layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover-out in a cell.

Page 233: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 217

Measurement Point

C10954 increments when BSC receives measurements report, handover decision occurs and RADIO APPLY message is sent to destination cell.

C10955 Definition

Number of successful handover out to same layer and from GSM900 to GSM1800

Description

C10955 represents number of successful handover out to same layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

Counter C10955 increments when serving cell receives HANDOVER COMPLETE message.

C10956 Definition

Number of handover in attempts from upper layer and from GSM900 to GSM1800

Description

C10956 represents number of handover in attempts from upper layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in a cell.

Measurement Point

Counter C10956 increments when destination cell receives RADIO APPLY message.

C10957 Definition

Number of handover in attempts from upper layer and from GSM900 to GSM1800

Description

C10957 represents number of handover in attempts from upper layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in at the cell.

Page 234: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

218 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter C10957 increments when source cell receives CHL ACTIVE ACK message.

C10958 Definition

Number of handover in successes from upper layer and from GSM900 to GSM1800

Description

C10958 represents number of successful handover in from upper layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in a cell.

Measurement Point

C10958 increments when destination cell receives HANDOVER COMPLETE message.

C10959 Definition

Number of handover out attempts to upper layer and form GSM900 to GSM1800

Description

C10959 represents number of handover out attempts to upper layer and (from GSM900 to GSM1800during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10960 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

C10960 Definition

Number of successful handover out to upper layer and from GSM900 to GSM1800

Description

C10960 represents number of successful handover out to upper layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10960 increments when source cell receives HANDOVER COMPLETE message.

Page 235: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 219

C10961 Definition

Number of handover in attempts from lower layer and from GSM900 to GSM1800

Description

C10961 represents number of handover in attempts from lower layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10961 increments when destination cell receives RADIO APPLY message.

C10962 Definition

Number of handover in attempts from lower layer and from GSM900 to GSM1800

Description

C10962 represents number of handover in attempts from lower layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10963 increments when destination cell receives CHL ACTIVE ACK message.

C10963 Definition

Number of handover-in successes from lower layer and from GSM900 to GSM1800

Description

C10963 represents number of successful handover in from lower layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in at cell.

Measurement Point

C10963 increments when target cell receives HANDOVER COMPLETE message.

Page 236: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

220 Confidential and Proprietary Information of ZTE CORPORATION

C10964 Definition

Number of handover out attempts to lower layer and from GSM900 to GSM1800

Description

C10964 represents number of handover out attempts to lower layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10964 increments when BSC receives measurement report and it sends RADIO APPLY message to target cell.

C10965 Definition

Number of successful handover outs to lower layer and from GSM900 to GSM1800

Description

C10965 represents number of handover out to lower layer and from GSM900 to GSM1800 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10965 increments when serving cell receives HANDOVER COMPLETE message

C10966 Definition

Number of handover in attempts from same layer and from GSM1800 to GSM900

Description

C10966 represents number of handover in attempts from same layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10966 increments when destination cell receives RADIO APPLY message.

Page 237: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 221

C10967 Definition

Number of handover in attempts from same layer and from GSM1800 to GSM900

Description

C10967 represents number of handover in attempts from same layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

Counter C10967 increments when destination cell receives CHL ACTIVE ACK message.

C10968 Definition;

Number of successful handover in from same layer and from GSM1800 to GSM900

Description

C10968 represents number of successful handover in from same layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

Counter C10968 increments when the target cell receives HANDOVER COMPLETE message.

C10969 Definition

Number of handover out attempts to same layer and from GSM1800 to GSM900

Description

C10969 represents number of handover attempts to same layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10969 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

Page 238: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

222 Confidential and Proprietary Information of ZTE CORPORATION

C10970 Definition

Number of successful handover outs to same layer and from GSM1800 to GSM900

Description

C10970 represents number of successful handover to same layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10970 increments when destination cell receives HANDOVER COMPLETE message.

C10971 Definition

Number of handover in attempts from upper layer and from GSM1800 to GSM900

Description

C10971 represents number of handover in attempts from upper layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10971 increments when destination cell receives RADIO APPLY message.

C10972 Definition

Number of handover in attempts from upper layer and from GSM1800 to GSM900

Description

C10972 represents number of handover in attempts from upper layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

Counter C10972 increments when destination cell receives CHL ACTIVE ACK message.

Page 239: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 223

C10973 Definition

Number of successful handover in successes from upper layer and from GSM1800 to GSM900

Description

C10973 represents number of successful handover in from upper layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10973 increments when destination cell receives HANDOVER COMPLETE message.

C10974 Definition

Number of handover out attempts to upper layer from GSM1800 to GSM900

Description

C10974 represents number of handover-out attempts to upper layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover-out in a cell.

Measurement Point

C10974 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

C10975 Definition

Number of successful handover outs to upper layer and from GSM1800 to GSM900

Description

C10975 represents number o number of successful handover outs to upper layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10975 increments when serving cell receives HANDOVER COMPLETE message.

Page 240: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

224 Confidential and Proprietary Information of ZTE CORPORATION

C10976 Definition

Number of handover in attempts from lower layer and from GSM1800 to GSM900

Description

C10976 represents number of handover in attempts from lower layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover-in at a cell.

Measurement Point

C10976 increments when destination cell receives RADIO APPLY message.

C10977 Definition

Number of handover in attempts from lower layer and from GSM1800 to GSM900

Description

C10977 represents number of handover in attempts from lower layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10977 increments when destination cell receives CHL ACTIVE ACK message.

C10978 Definition

Number of successful handover ins from lower layer and from GSM1800 to GSM900

Description

C10978 represents number of successful handover in from lower layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in at a cell.

Measurement Point

C10978 increments when destination cell receives HANDOVER COMPLETE message.

Page 241: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 225

C10979 Definition

Number of handover out attempts to lower layer and from GSM1800 to GSM900

Description

C10979 represents number of handover out attempts to lower layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10979 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

C10980 Definition

Number of successful handover out-out to lower layer and from GSM1800 to GSM900

Description

C1090 represents number of successful handover out to lower layer and from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10980 increments when source cell receives HANDOVER COMPLETE message.

C10981 Definition

Number of Intra-cell handover attempts

Description

When an origination channel requires internal handover, it sends measurements report to BSC. BSC analyzes measurement report, according to handover algorithm. After handover analysis, the BSC decides whether internal handover is required or not. If internal handover is required, BSC sends RADIO APPLY message to destination channel.

Measurement Point

C10981 increments when BSC receives measurement report and it sends RADIO APPLY message to destination channel.

Page 242: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

226 Confidential and Proprietary Information of ZTE CORPORATION

C10982 Definition

Number of successful intra-cell handovers

Description

C10982 represents number of successful intra-cell handovers.

Measurement Point

C10982 increments when origination channel receives ASSIGN COMPLETE message.

C10983 Definition

Number of intra-cell and inner-circle-to-outer-circle handover attempts

Description

C10983 represents number of intra-cell and inner-circle-to-outer-circle handover attempts during intra-cell handover in a concentric circle cell.

For the non-concentric circle cell, following counters related with concentric circle cell is same as intra-cell handover counters.

Measurement Point

C10984 increments when BSC receives measurement report and the BSC sends RADIO APPLY message to destination cell.

C10984 Definition

Number of time of successful intra-cell and inner-circle-to-outer-circle handover

Description

C10984 represents number of successful intra-cell and inner-circle-to-outer-circle handovers during intra-cell handover in a concentric circle cell.

Measurement Point

C10984 increments when serving cell receives ASSIGN COMPLETE message.

C10985 Definition

Number of intra-cell and outer-circle-to-inner-circle handover attempts

Page 243: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 227

Description

C10985 represents number of intra-cell and outer-circle-to-inner-circle handover attempts during intra-cell handover in a concentric circle cell.

Measurement Point

C10985 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

C10986 Definition

Number of successful intra-cell and outer-circle-to-inner-circle handovers

Description

C10987 represents number of intra-cell and outer-circle-to-inner-circle handover attempts during intra-cell handover in a concentric circle cell.

Measurement Point

C10987 increments when destination cell receives ASSIGN COMPLETE message.

C10987 Definition

Number of intra-cell and inner-circle-to-inner-circle handover attempts

Description

C1987 represents number of intra-cell and inner-circle-to-inner-circle handover attempts during intra-cell handover in a concentric circle cell.

Measurement Point

C10987 increments when BSC receives measurement report and BSC sends RADIO APPLY message to destination cell.

C10988 Definition

Number of successful intra-cell and inner-circle-to-inner-circle handovers

Description

C10988 represents number of successful intra-cell and inner-circle-to-inner-circle handovers during intra-cell handover in a concentric circle cell.

Page 244: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

228 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C10988 increments when serving cell receives ASSIGN COMPLETE message

C10989 Definition

Number of Intra-cell and outer-circle-to-outer-circle handover attempts

Description

C10989 represents number of intra-cell and outer-circle-to-outer-circle handover attempts during intra-cell handover in a concentric circle cell.

Measurement Point

C10989 increments when BSC receives measurement report and it sends RADIO APPLY message to destination cell.

C10990 Definition

Number of successful intra-cell and outer-circle-to-outer-circle handovers

Description

C1090 represents number of intra-cell and outer-circle-to-outer-circle handover attempts during intra-cell handover in a concentric circle cell.

Measurement Point

C10991 increments when serving cell receives ASSIGN COMPLETE message.

C10991 Definition

Number of handover out executions from GSM1800 to GSM900

Description

C10991 represents number of handover out executions from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in a cell.

Measurement Point

C10991 increments when BSC receives RADIO AVAIL message from destination cell.

Page 245: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 229

C10992 Definition

Number of handover out executions from GSM900 to GSM1800

Description

C10992 represents number of handover executions from GSM900 to GSM1800 during Intra-BSC inter-cell outgoing handover in a cell.

Measurement Point

C10992 increments when BSC receives RADIO AVAIL message from destination cell.

C10993 Definition

Number of 2G to 3G handover attempts

Description

C10993 represents number of GSM-to-UTRAN handover attempts.

Measurement Point

C10993 increments when BSC judges requirement of GSM cell to UTRAN cell handover and BSC of GSM system sends HANDOVER REQUIRED message to BSC of UTRAN system.

C10994 Definition

Number of 2G to 3G handover executions

Description

C10994 represents number of GSM-to-UTRAN handover executions.

Measurement Point

C10994 increments when BSC receives HANDOVER COMMAND message from UTRAN. It then forwards it to MS.

C10995 Definition

Number of successful 2G to 3G handovers

Description

C10995 represents number of successful GSM-to-UTRAN handovers.

Page 246: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

230 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C10995 increments when BSC of GSM system receives CLEAR COMMAND.

C10996 Definition

Number of 3G to 2G handover attempts

Description

C10996 represents number of UTRAN-to-GSM handover attempts

Measurement Point

C10996 increments when destination cell receives RADIO APPLY message.

C10997 Definition

Number of 3G to 2G handover executions

Description

C10997 represents number of UTRAN-to-GSM handover executions

Measurement Point

C10997 increments when destination cell receives CHL ACTIVE ACK message.

C10998 Definition

Number of successful 3G to 2G handovers

Description

C10998 represents number of successful UTRAN-to-GSM handovers

Measurement Point

C10998 increments when destination cell receives HANDOVER COMPLETE message.

C10999 Definition

Number of intra-cell handover attempts from TCH/F

Page 247: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 231

Description

This index provides statistics for handover out attempts from TCH/F channel at intra-cell handover.

Measurement Point

C10999 increments when destination cell receives RADIO APPLY message.

C109100 Definition

Number of intra-cell and TCH/F-to-TCH/F handover executions

Description

C109100 represents number of handover-out executions from TCH/F channel to TCH/F channel during intra-cell handover.

Measurement Point

C109100 increments when destination cell receives CHL ACTIVE ACK message.

C109101 Definition

Number of successful intra-cell and TCH/F-to-TCH/F handovers

Description

Counter C109101 represents number of successful handover out from TCH/F channel to TCH/F channel during intra-cell handover.

Measurement Point

C109101 increments when destination cell receives ASSIGN COMPLETE message.

C109102 Definition

Number of intra-cell and TCH/F-to-TCH/H handover executions

Description

C109102 represents number of handover out executions from TCH/F channel to TCH/H during intra-cell handover.

Measurement Point

C109102 increments when destination cell receives CHL ACTIVE ACK message.

Page 248: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

232 Confidential and Proprietary Information of ZTE CORPORATION

C109103 Definition

Number of successful intra-cell and TCH/F-to-TCH/H

Description

r C109103 represents number of successful handover out from TCH/F channel to TCH/H during intra-cell handover.

Measurement Point

C109103 increments when destination cell receives ASSIGN COMPLETE message.

C109104 Definition

Number of intra-cell handover attempts from TCH/H

Description

C109104 represents number of handover out attempts from TCH/H during intra-cell handover.

Measurement Point

C109104 increments when destination cell receives RADIO APPLY message.

C109105 Definition

Number of intra-cell handover executions from TCH/H-to-TCH/F

Description

C109106 represents number of handover out executions from TCH/H to TCH/F channel during intra-cell handover.

Measurement Point

C109106 increments when destination cell receives CHL ACTIVE ACK message.

C109106 Definition

Number of successful intra-cell handovers from TCH/H-to-TCH/F

Description

C109106 represents number of successful handover out from TCH/H to TCH/F channel during intra-cell handover.

Page 249: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 233

Measurement Point

C109106 increments when destination cell receives ASSIGN COMPLETE message.

C109107 Definition

Number of intra-cell handover executions from TCH/H-to-TCH/H

Description

C109107 represents number of handover out executions from TCH/H to TCH/H during intra-cell handover.

Measurement Point

C109107 increments when destination cell receives CHL ACTIVE ACK message.

C109108 Definition

Number of successful intra-cell handovers from TCH/H-to-TCH/H

Description

C109109 represents number of successful handover out from the TCH/H to TCH/H at intra-cell handover.

Measurement Point

C109109 increments when destination cell receives ASSIGN COMPLETE message.

C109109 Definition

Number of inter-cell handover attempts from TCH/F

Description

C109109 represents number of handover out attempts from TCH/F channel during Intra-BSC inter-cell handover.

Measurement Point

C109109 increments when destination cell receives RADIO APPLY message.

C109110 Definition

Number of inter-cell handover executions from TCH/F-to-TCH/F

Page 250: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

234 Confidential and Proprietary Information of ZTE CORPORATION

Description

C109110 represents number of handover out executions from TCH/F channel to TCH/F channel during Intra-BSC inter-cell handover.

Measurement Point

C109110 increments when destination cell receives CHL ACTIVE ACK message.

C109111 Definition

Number of successful inter-cell handover from TCH/F-to-TCH/F

Description

C109111 represents number of successful handover out from TCH/F channel to TCH/F channel during Intra-BSC inter-cell handover.

Measurement Point

C109111 increments when destination cell receives ASSIGN COMPLETE message.

C109112 Definition

Number of inter-cell handover executions from TCH/F-to-TCH/H

Description

C10912 represents number of handover out executions from TCH/F channel to TCH/H during Intra-BSC inter-cell handover.

Measurement Point

C109112 increments when destination cell receives CHL ACTIVE ACK message.

C109113 Definition

Number of successful inter-cell handovers from TCH/F-to-TCH/H

Description

C109113 represents number of successful handover out from TCH/F channel to TCH/H during Intra-BSC inter-cell handover.

Measurement Point

C109113 increments when destination cell receives ASSIGN COMPLETE message.

Page 251: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 235

C109114 Definition

Number of inter-cell handover attempts from TCH/H

Description

C109113 represents number of handover out attempts from TCH/H during Intra-BSC inter-cell handover.

Measurement Point

C109114 increments when destination cell receives RADIO APPLY message.

C109115 Definition

Number of inter-cell handover executions from TCH/H-to-TCH/F

Description

C109115 represents number of handover out executions from TCH/H to TCH/F channel during Intra-BSC inter-cell handover.

Measurement Point

C109115 increments when destination cell receives CHL ACTIVE ACK message.

C109116 Definition

Number of successful inter-cell handovers from TCH/H-to-TCH/F

Description

C109116 represents number of successful handover out from TCH/H to TCH/F channel during Intra-BSC inter-cell handover.

Measurement Point

C109116 increments when destination cell receives ASSIGN COMPLETE message

C109117 Definition

Number of inter-cell handover executions from TCH/H-to-TCH/H

Description

C109117 represents number of handover out executions from TCH/H to TCH/H during Intra-BSC inter-cell handover.

Page 252: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

236 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter increments when destination cell receives CHL ACTIVE ACK message.

C109118 Definition

Number of successful inter-cell handovers from TCH/H-to-TCH/H

Description

C109118 represents number of successful handover out from TCH/H to TCH/H during Intra-BSC inter-cell handover.

Measurement Point

C109118 increments when destination cell receives ASSIGN COMPLETE message.

C109119 Definition

Number of double-frequency external handover out attempts

Description

C10919 represents number of handover attempts from serving cell band to destination cell different band during Intra-MSC external handover.

Measurement Point

C109110 increments when serving BSC sends HANDOVER REQUIRED message to destination cell upon receiving MS measurement report.

C109120 Definition

Number of double-frequency external handover out executions

Description

C109120 represents number of handover out executions between serving cell band and different destination cell band during Intra-MSC external handover.

Measurement Point

C109120 increments when BSC receives HANDOVER COMMAND message from A-interface and it sends HANDOVER COMMAND message to MS.

Page 253: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 237

C109121 Definition

Number of successful double-frequency external handover outs

Description

C109121 represents number of successful handovers between serving cell band and different destination cell band during Intra-MSC external handover.

Measurement Point

C109121 increments when BSC receives CLEAR COMMAND message from A-interface.

C109122 Definition

Number of double-frequency external handover-in attempts

Description

C109122 represents number of handover attempts between serving cell bands different from destination cell band during Intra-MSC external handover-in.

Measurement Point

C109123 increments when destination cell receives HANDOVER REQUEST message from A-interface.

C109123 Definition

Number of double-frequency external handover in attempts

Description

C109123 represents number of handover executions between serving cell band and different destination cell band during Intra-MSC external handover-in.

Measurement Point

C109123 increments when destination cell receives CHL ACTIVE ACK message.

C109124 Definition

Number of successful double-frequency external handover ins

Page 254: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

238 Confidential and Proprietary Information of ZTE CORPORATION

Description

C109124 represents number of successful handovers between serving cell band and different destination cell band during Intra-MSC external handover in.

Measurement Point

C109124 increments when destination cell receives HANDOVER COMPLETE message.

C109125 Definition

Number of intra-cell invalid handovers

Description

C109125 represents number of invalid handover. During intra-cell handover, due to uplink or down link interference an MS get a new channel in a new cell. Again if there is uplink and downlink interference occur in new cell MS want to do another handover from recently resided cell. At this time, BSC prohibits the MS from handover due to invalid handover.

Measurement Point

C109125 increments when an MS requires intra-cell handover due to same uplink or downlink interference.

C109126 Definition

Intra-BSC handover-in forced release attempts

Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell handover, this index is used to count the number of obtaining resource by forced release method when no wireless channels are available, which helps to provide frequency information of the forced release of the serving cell which is implemented during intra-BSC inter-cell handover-in or intra-BSC intra-cell handover in the serving cell.

Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the application cause is the inter-cell or intra-cell handover. Counter increments when the forced release is implemented to obtain resource.

Page 255: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 11 - General Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 239

C109127 Definition

Intra-BSC handover-in executions (forced release)

Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell handover, this index is used to count the number of channel handover by forced release method, which helps to provide frequency information of channel handover by forced release during the inter-BSC inter-cell or inter-BSC intra-cell handover in the serving cell.

Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the application cause is the inter-cell or intra-cell handover. Counter increments when the forced release is implemented to obtain resource.

C109128 Definition

Intra-BSC handover-in queue attempts

Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell handover, this index is used to count the number of queuing for resource when no wireless channels are available, which helps to provide frequency information of the queuing which is implemented during intra-BSC inter-cell handover-in or intra-BSC intra-cell handover in the serving cell.

Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the application cause is the inter-cell or intra-cell handover. Counter increments when the queuing for resource is implemented.

C109129 Definition

Intra-BSC handover-in executions (queue)

Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell handover, this index is used to count the number of getting the resource after queuing when no wireless channels are available, which helps to provide frequency information of getting the resource after queuing which is implemented during intra-BSC inter-cell handover-in or intra-BSC intra-cell handover in the serving cell.

Page 256: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

240 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the application cause is the inter-cell or intra-cell handover. Counter increments when the resource is got after queuing.

Page 257: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 241

C h a p t e r 12

Synchronization Mode Handover Measurement

This chapter covers the following topics:

Synchronization Mode Handover Counters

Synchronization Mode Counters These counters provide statistics for Synchronization Mode handovers. Synchronization mode includes Synchronized, non-synchronized, pseudo, asynchronous and pre-synchronous handovers. For Synchronized handovers it requires that the clock of all involving cells should finely synchronize.

Table 20 lists all the Synchronized handover counters.

TAB L E 20 S Y N C H R O N I Z E D H AN D O V E R C O U N T E R S

Counter No. Counter Definition

C11201 Number of synchronous handover executions

C11202 Number of successful synchronous handovers

C11203 Number of pre-synchronous handover executions

C11204 Number of successful pre-synchronous handovers

C11205 Number of pseudo-synchronous handover executions

C11206 Number of successful pseudo-synchronous handovers

C11207 Number of asynchronous handover executions

C11208 Number of successful asynchronous handovers

Page 258: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

242 Confidential and Proprietary Information of ZTE CORPORATION

Synchronization Mode Counters Explanation C11201 Definition

Number of synchronous handover executions

Description

C11201 represents number of handover executions in synchronous handover mode. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover. Channel activation cause is synchronous handover mode.

Measurement Point

C11201 increments when serving cell receive CHLACTIVE ACK message.

C11202 Definition

Number of successful synchronous handovers

Description

C11202 represents number of successful synchronous handover. In this scenario there are intra-cell handover, Intra-MSC external handover in and Intra-BSC inter-cell handover.

Measurement Point

C11202 increments when serving cell receives ASSIGN COMPLETE message during intra-cell synchronous handover. Similarly C11202 increments when serving cell receive HANDOVER COMPLETE message during Intra-MSC external cell handover or Intra-BSC inter-cell synchronous handover.

C11203 Definition

Number of pre-synchronous handover executions

Description

C11203 represents number of handover executions in pre-synchronous handover mode. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover. Channel activation cause is pre-synchronous handover mode.

Page 259: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 12 - Synchronization Mode Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 243

Measurement Point

C11203 increments when serving cell receives CHL ACTIVE ACK message during Intra-MSC external handover in or Intra-BSC inter-cell handover.

C11204 Definition

Number of successful pre-synchronous handovers

Description

C11204 represents number of successful pre-synchronous handovers. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover.

Measurement Point

C11204 increments when serving cell receives HANDOVER COMPLETE message during Intra-MSC external handover or Intra-BSC inter-cell handover.

C11205 Definition

Number of pseudo-synchronous handover executions

Description

C11205 represents number of pseudo-synchronous handover executions. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover. Channel activation cause is synchronous handover mode.

Measurement Point

C11205 increments when serving cell receives CHL ACTIVE ACK message during Intra-MSC external handover in or Intra-BSC inter-cell handover.

C11206 Definition

Number of successful pseudo-synchronous handovers

Description

C11206 represents number of successful pseudo-synchronous handovers. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover.

Measurement Point

Page 260: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

244 Confidential and Proprietary Information of ZTE CORPORATION

C11206 increments when serving cell receives HANDOVER COMPLETE message during Intra-MSC external handover of Intra-BSC inter-cell handover.

C11207 Definition

Number of asynchronous handover executions

Description

C11207 represents number of asynchronous handover executions. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover.

Measurement Point

C11207 increments when serving cell receives CHL ACTIVE ACK message during Intra-MSC external handover in or Intra-BSC inter-cell handover.

C11208 Definition

Number of successful asynchronous handovers

Description

C11208 represents number of successful asynchronous handover. In this scenario there are Intra-MSC external handover in and Intra-BSC inter-cell handover.

Measurement Point

C11208 increments when serving cell receives HANDOVER COMPLETE message during Intra-MSC external handover in of Intra-BSC inter-cell handover.

Page 261: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 245

C h a p t e r 13

Paging Message Measurement

This chapter covers the following topics:

Paging Message Counter

Paging Message Counter Table 21 defines paging measurement counter.

TAB L E 21 P AG I N G M E S S AG E C O U N T E R

Counter No. Counter Definition

C11301 Number of sent paging message

C11301 Definition

Number of sent paging message

Description

C11301 provide statistics for number paging messages send to each relevant cell after BSC receives the paging command from A-interface.

Measurement Point

C11301 increments when BSC sends PAGING COMMAND to the relevant cell.

Page 262: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

246 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank

Page 263: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 247

C h a p t e r 14

Abis-Interface Signaling

This chapter covers the following topics:

Abis-interface Measurement

Abis-interface Measurement Abis-interface Measurement includes counters that provide signaling statistics of Abis-interface. These counters keep the statistics of all the messages that BSC receives or send on the Abis-interface.

Abis-interface Counters Table 22 lists all the Abis-interface message counters.

TAB L E 22 AB I S - I N T E R F AC E M E S S AG E C O U N T E R S

Counter No. Counter Definition

C11401 Number of DATA REQUEST messages

C11402 Number of DATA INDICATION messages

C11403 Number of ERROR INDICATION messages

C11404 Number of ESTABLISH REQUEST messages

C11405 Number of ESTABLISH CONFIRM messages

C11406 Number of ESTABLISH INDICATION messages

C11407 Number of RELEASE REQUEST messages

C11408 Number of RELEASE CONFIRM messages

C11409 Number of RELEASE INDICATION messages

C11410 Number of UNIT DATA REQUEST messages

C11411 Number of UNIT DATA INDICATION messages

C11412 Number of CHANNEL ACTIVATION messages

C11413 Number of CHANNEL ACTIVATION ACK messages

Page 264: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

248 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C11414 Number of CHANNEL ACTIVATION Negative ACK messages

C11415 Number of CONNECTION FAILURE INDICATION messages

C11416 Number of DEACTIVATE SACCH messages

C11417 Number of ENCRYPTION COMMAND messages

C11418 Number of HANDOVER DETECTION messages

C11419 Number of MEASUREMENT RESULT messages

C11420 Number of MODE MODIFY REQUEST messages

C11421 Number of MODE MODIFY ACKNOWLDGE messages

C11422 Number of MODE MODIFY NEGATIVE ACKNOWLDGE messages

C11423 Number of PHYSICAL CONTEXT REQUEST messages

C11424 Number of PHYSICAL CONTEXT CONFIRM messages

C11425 Number of RF CHANNEL RELEASE messages

C11426 Number of MS POWER CONTROL messages

C11427 Number of BS POWER CONTROL messages

C11428 Number of PREPROCESSED CONFIGURE messages

C11429 Number of PREPROCESSED MEASUREMENT RESULT messages

C11430 Number of RF CHANNEL RELEASE ACK messages

C11431 Number of SACCH INFO MODIFY messages

Abis-interface Counters Explanation C11401 Definition

Number of DATA REQUEST messages

Description

C11401 represents number of data REQUEST message needs acknowledgement in the messages send from BSC to LAPD.

Measurement Point

C11401 increments when BSC sends DATA REQUEST message to LAPD.

C11402 Definition

Number of DATA INDICATION messages

Description

C11402 represents number of data indication messages that BSC receives through Abis-interface.

Page 265: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 14 - Abis-Interface Signaling

Confidential and Proprietary Information of ZTE CORPORATION 249

Measurement Point

C11402 increments when BSC receives DATA INDICATION message.

C11403 Definition

Number of ERROR INDICATION messages

Description

When an error occurs in radio channel, BTS sends ERROR INDICATION message to BSC. C11403 represents number of ERROR INDICATION messages that BSC receives through Abis-interface.

Measurement Point

C11403 increments when BSC receives ERROR INDICATION message.

C11404 Definition

Number of ESTABLISH REQUEST messages

Description

C11404 represents number of ESTABLISH REQUEST messages that BSC sends to LAPD. Initially BSC receives short message through A-interface that BSC sends to MS. To originate link establishment process for short message to MS, BSC sends ESTABLISH REQUEST message to LAPD.

Measurement Point

C11404 increments when BSC sends ESTABLISH REQUEST message to LAPD.

C11405 Definition

Number of ESTABLISH CONFIRM messages

Description

C11405 represents number of confirmation messages that BSC receives through Abis-interface. Initially BSC receives ESTABLISH CONFIRM message from LAPD. ESTABLISH CONFIRM message indicates that the link is established successfully. At this time BSC sends short message to MS.

Measurement Point

C11405 increments when BSC receives ESTABLISH CONFIRM message.

Page 266: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

250 Confidential and Proprietary Information of ZTE CORPORATION

C11406 Definition

Number of ESTABLISH INDICATION messages

Description

C11406 represents number of link ESTABLISH INDICATION messages that BSC receives through Abis-interface. Initially MS receives assignment command or handover command from BSC. Then MS sends SABM frame to BTS. When BTS receives SABM frame, it sends link ESTABLISH INDICATION message to BSC. At this time BSC sends short message to MS.

Measurement Point

C11406 increments when BSC receives ESTABLISH INDICATION message.

C11407 Definition

Number of RELEASE REQUEST messages

Description

C11407 represents number of RELEASE REQUEST through Abis-interface that BSC sends to LAPD.

Measurement Point

C11407 increments when BSC sends RELEASE REQUEST message to LAPD.

C11408 Definition

Number of RELEASE CONFIRM messages

Description

C11408 represents number of RELEASE CONFIRM messages that BSC receives through Abis-interface.

Measurement Point

C11408 increments when BSC receives RELEASE CONFIRM message.

C11409 Definition

Number of RELEASE INDICATION messages

Page 267: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 14 - Abis-Interface Signaling

Confidential and Proprietary Information of ZTE CORPORATION 251

Description

After the BSC sends RELEASE REQUEST, the MS releases the channel, and the BTS sends the BSC the RELEASE INDICATION as a reply. This counter provides statistics for the number of release confirm messages that BSC receives through Abis-interface.

Measurement Point

C11409 increments when BSC receives RELEASE INDICATION message.

C11410 Definition

Number of UNIT DATA REQUEST messages

Description

C11410 represents number of unacknowledged data REQUEST messages through Abis-interface that BSC sends to LAPD.

Measurement Point

C11410 increments when BSC sends UNIT DATA REQUEST message to LAPD.

C11411 Definition

Number of UNIT DATA INDICATION messages

Description

C11411 represents number of unacknowledged data indication messages that BSC receives through Abis-interface.

Measurement Point

C11410 increments when BSC sends UNIT DATA INDICATION message to LAPD.

C11412 Definition

Number of CHANNEL ACTIVATION messages

Description

C11412 represents number of channel activation messages send from BSC to LAPD. Initially BSC gets ready to activate a channel due to all type of causes. Then the BSC sends CHANNEL ACTIVATION message to BTS to start channel activation flow.

Page 268: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

252 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C11412 increments when BSC sends CHANNEL ACTIVATION message to LAPD.

C11413 Definition

Number of CHANNEL ACTIVATION ACK messages

Description

C11413 represents number of channel activation acknowledgement messages send from BSC to LAPD. Initially BTS activate channel due to CHANNEL ACTIVATION message from BSC. After completing channel activation, BTS sends CHANNEL ACTIVATION ACK message to BSC. CHANNEL ACTIVATION ACK message is a response from BTS to CHANNEL ACTIVATION message from BSC.

Measurement Point

C11414 increments when BSC receives CHANNEL ACTIVATION ACK message from BTS.

C11414 Definition

Number of CHANNEL ACTIVATION Negative ACK messages

Description

When the BTS cannot complete channel activation due to a cause (like a TRX fault), it sends CHANNEL ACTIVATION NEGATIVE ACK to the BSC. This counter provides statistics for the number of channel activation failure acknowledgement messages that BSC receives through Abis-interface.

Measurement Point

C11414 increments when BSC receives CHANNEL ACTIVATION NEGATIVE ACK message from BTS.

C11415 Definition

Number of CONNECTION FAILURE INDICATION messages

Description

C11415 represents number of channel activation failure acknowledgement messages that BSC receives through Abis-interface.

Initially BTS can not establish connection with MS due to different causes like TRX fault. Then the BTS sends CONNECTION FAILURE INDICATION to BSC to inform it about connection failure.

Page 269: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 14 - Abis-Interface Signaling

Confidential and Proprietary Information of ZTE CORPORATION 253

Measurement Point

C11415 increments when BSC receives CONNECTION FAILURE INDICATION message from.

C11416 Definition

Number of DEACTIVATE SACCH messages

Description

C11416 represents number of DEACTIVATE SACCH messages send from BSC to LAPD. Initially BSC is ready to deactivate SACCH due to radio channel release. Then BSC SENDS DEACTIVATE SACCH message to LAPD to start deactivation flow.

Measurement Point

C11416 increments when BSC sends DEACTIVATE SACCH message to LAPD.

C11417 Definition

Number of ENCRYPTION COMMAND messages

Description

C11417 represents number of encryption commands messages send from BSC to LAPD. Initially BSC sends ENCRIPTION COMMAND message to MS to perform encryption process.

Measurement Point

C11417 increments when BSC sends ENCRYPTION COMMAND message to LAPD.

C11418 Definition

Number of HANDOVER DETECTION messages

Description

C11418 represents number of handover detection messages that BSC receives through Abis-interface. Initially MS receives handover command from BTS during Intra-MSC external handover-in process. Then MS sends SABM frame to start network access process. BTS sends HANDOVER DETECTION message to inform BSC after receiving SABM frame from MS.

Page 270: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

254 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 18 - E X T E R N AL H AN D O V E R I N P R O C E S S (P AR T FL O W )

BTSMS BSC:Dest

HANDOVER DETECT

MSCBSC:Souce

HANDOVER COMMANDHANDOVER COMMAND

SABM

UAA1

Measurement Point

Refer point A1 in FIGURE 18.

C11419 Definition

Number of MEASUREMENT RESULT messages

Description

C11419 represents number of received MEASUREMENT RESULT messages from BTS among Abis-interface messages received at BSC.

Measurement Point

C11419 increments when BSC receives MEASUREMENT RESULT messages in Abis-interface message.

C11420 Definition

Number of MODE MODIFY REQUEST messages

Description

C11421 represents number of MODE MODIFY REQUEST messages that BSC sends through Abis-interface during assignment or handover process.

If assigned channel type is consistent with current channel type and channel modes are inconsistent then BSC sends MODE MODIFY REQUEST to BTS. At this time, C11420 increments

Measurement Point

C11420 increments when BSC sends MODE MODIFY REQUEST message to BTS.

Page 271: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 14 - Abis-Interface Signaling

Confidential and Proprietary Information of ZTE CORPORATION 255

C11421 Definition

Number of MODE MODIFY ACK messages

Description

C11422 represents number of MODE MODIFY ACK messages that BSC receives through Abis-interface. Initially BTS receives MODE MODIFY REQUEST message from BSC. Then the BTS sends MODE MODIFY ACK message to BSC in reply.

Measurement Point

C11421 increments when BSC receives MODE MODIFY ACK message in Abis-interface message.

C11422 Definition

Number of MODE MODIFY Negative ACK messages

Description

C11422 represents number of MODE MODIFY Negative ACK messages that BSC receives through Abis-interface. Initially BTS receives MODE MODIFY REQUEST message from BSC. If BTS can not complete channel mode modification due to some causes, the BTS sends negative acknowledgment to BSC in reply.

Measurement Point

C11422 increments when BSC receives MODE MODIFY NACK message in Abis-interface message.

C11423 Definition

Number of PHYSICAL CONTEXT REQUEST messages

Description

C11423 represents number of PHYSICAL CONTEXT REQUEST messages that BSC sends through Abis-interface.

Measurement Point

C1423 increments when BSC sends PHYSICAL CONTEXT REQUEST message to BTS.

Page 272: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

256 Confidential and Proprietary Information of ZTE CORPORATION

C11424 Definition

Number of PHYSICAL CONTEXT CONFIRM messages

Description

C11425 represents number of PHYSICAL CONTEXT CONFIRM messages that BSC receives through Abis-interface.

Measurement Point

C11424 increments when BSC receives PHYSICAL CONTEXT CONFIRM through Abis-interface message.

C11425 Definition

Number of RF CHANNEL RELEASE messages

Description

C11425 represents number of RF CHANNEL RELEASE messages send from BSC to LAPD. BSC sends RF CHANNEL RELEASE message to BTS to indicate channel release.

Measurement Point

C11426 increments when BSC sends RF CHANNEL RELEASE message.

C11426 Definition

Number of MS POWER CONTROL messages

Description

BSC sends the MS POWER CONTROL message to the MS for power control. This counter provides statistics of the quantity of MS POWER CONTROL messages send from BSC to LAPD.

Measurement Point

C11426 increments when BSC sends MS POWER CONTROL message.

C11427 Definition

Number of BS POWER CONTROL messages

Page 273: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 14 - Abis-Interface Signaling

Confidential and Proprietary Information of ZTE CORPORATION 257

Description

BSC sends the BS POWER CONTROL message to the BS for power control. This counter provides statistics for the number of BS POWER CONTROL messages send from the BSC to LAPD.

Measurement Point

C11427 increments when BSC sends BS POWER CONTROL message to BTS.

C11428 Definition

Number of PREPROCESSED CONFIGURE messages

Description

C11428 represents number of PREPROC CONFIG messages send from BSC to LAPD.

Measurement Point

C11429 increments when BSC sends PREPROC CONFIG message.

C11429 Definition

Number of PREPROCESSED MEASUREMENT RESULT messages

Description

C11429 represents number of PREPROCESSED MEASUREMENT RESULT messages that BSC receives through Abis-interface from BTS.

Measurement Point

C11429 increments when BSC receives PREPROCESSED MEASUREMENT RESULT message in Abis-interface message.

C11430 Definition

Number of RF CHANNEL RELEASE ACK messages

Description

C11430 represents RF CHANNEL RELEASE ACK messages that BSC receives through Abis-interface. Initially BSC sends RF CHANNEL RELEASE message to BTS and MS to start channel release flow. Then BTS and MS complete channel release process and send RF CHANNEL RELEASE ACK message as reply to BSC.

Page 274: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

258 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C11230 increments when BSC receives RF CHANNEL RELEASE ACK in Abis-interface message.

C11431 Definition

Number of SACCH INFO MODIFY messages

Description

C11431 numbers of SACCH INFO MODIFY messages send from BSC to LAPD. BSC sends SACCH INFO MODIFY message to intra-cell MS to inform it about system information modification.

Measurement Point

C11431 increments when BSC sends SACCH INFO MODIFY message.

Page 275: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 259

C h a p t e r 15

Resource Availability Measurement

This chapter covers the following topics:

Resource Availability Counters

Resource Availability Counters Resource Availability Measurement involves counters that provide statistics of channels utilization in a cell. These counters keep the record of the following statistics.

Number of available SDCCH

TCH/H and TCH/F

Average and maximum busy quantities

Total busy time

Total congestion time in cell.

Statistical unit is cell.

Table 23 lists all the Resource Availability Counters.

TAB L E 23 R E S O U R S E AV AI L AB I L I T Y C O U N T E R S

Counter No. Counter Definition

C11501 Mean number of available SDCCHs

C11502 Mean number of unavailable SDCCHs

Page 276: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

260 Confidential and Proprietary Information of ZTE CORPORATION

C11503 Maximum number of busy SDCCHs

C11504 Mean number of busy SDCCHs

C11505 Total SDCCH busy time

C11506 Total SDCCH congestion time

C11507 Mean number of available TCH/Hs

C11508 Mean number of unavailable TCH/Hs

C11509 Maximum number of busy TCH/Hs

C11510 Mean number of busy TCH/Hs

C11511 Total TCH/H busy time

C11512 Total TCH/H congestion time

C11513 Mean number of available TCH/Fs

C11514 Mean number of unavailable TCH/Fs

C11515 Maximum number of busy TCH/Fs

C11516 Mean number of busy TCH/Fs

C11517 Total TCH/F busy time

C11518 Total TCH/F congestion time

C11519 Total number of TRXs

C11520 Total number of healthy TRXs

C11521 Seizure duration of reserved full rate channel

Resource Availability Counters Explanation C11501 Definition

Mean number of available SDCCHs

Description

C11501 represents mean number of SDCCHs available for use in the observed cell.

Measurement Point

C11501 records the result at periodic querying of data base.

C11502 Definition

Mean number of unavailable SDCCHs

Page 277: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 15 - Resource Availability Measurement

Confidential and Proprietary Information of ZTE CORPORATION 261

Description

C11502 represents mean number of SDCCHs unavailable for use in the observed cell including both, idle and busy SDCCHs.

Measurement Point

C11502 records the result at periodic querying of data base.

C11503 Definition

Maximum number of busy SDCCHs

Description

C11503 represents maximum number of SDCCHs that are busy during the observation period.

C11503 increments, if MS occupies SDCCH successfully. C11503 decrements, if MS fails to occupy SDCCH. BSC updates C11503 according to number of seize SDCCHs in a cell, during measurement query. Before MS releases SDCCH in a cell, C11503 also updates number of seize SSDCH channels. C11503 updates number of seize SDCCHs because seizure of SDCCHs in a cell of previous measurement cycle is taken into account.

Measurement Point

C11503 increments at three measurement points:

If maximum busy quantity exceeds the represented value after SDCCH in cell is seize successfully.

If maximum busy quantity exceeds the represented value before SDCCH in cell is released.

If maximum busy quantity exceeds the represented value at time of measurement query.

C11504 Definition

Mean number of busy SDCCH

Description

C11504 represents mean number of SDCCHs that are busy during the observation period.

Measurement Point

During the time measurement cycle, system updates the status of SDCCH (busy or idle) in C11504.

Page 278: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

262 Confidential and Proprietary Information of ZTE CORPORATION

C11505 Definition

Total SDCCHs busy time

Description

C11505 represents total time of SDCCH seizures in a cell. C11505 shows traffic of SDCCHs in a cell.

Measurement Point

C11505 increments when:

MS seizes SDCCH successfully.

MS releases SDCCH.

During timely measurement.

Reported measurement value is accumulation of each measurement value. After each measurement, current time is set as last time for the next measurement. When MS seizes SDCCH successfully, number of seized SDCCH increments by one. When MS releases SDCCH, number of seized SDCCH decrements by one.

Measurement formula:

(Current time – time of last measurement) X (Number of seized SDCCHs)

FIGURE 19 shows measurement calculation procedure.

FIGURE 19 - C AL C U L AT I N G S D C C H B U S Y T I M E

Measurementcircle

SDCCH occupy or releaseOccupation time + = (current time - previous

record time) × occupied quantityPrevious record time = current time

1 added to or reduced from the occupied quantity

SDCCH occupy or releaseSame as the above calculation

Measurement value Same as the above calculation

Time Time

C11506 Definition

Total SDCCH congestion time

Page 279: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 15 - Resource Availability Measurement

Confidential and Proprietary Information of ZTE CORPORATION 263

Description

C11506 represents total SDCCH congestion time. At this time cell can not apply for SDCCH. C11506 marks congestion when MS fails to occupy SDCCH. Similarly counter C11506 clears congestion mark when MS successes to occupy SDCCH. Initially counter C11506 sets congestion mark during SDCCH application. C11506 obtains congestion time at this period by reducing the previous record congestion time from current time. Sum of congestion time of each calculation is the total SDCH channel congestion time.

Measurement Point

C11506 increments at three points:

If congestion mark is set before MS attempts to occupy SDCCH

If congestion mark is set before MS release SDCCH

If congestion mark is set at time of measurement query

C11507 Definition

Mean number of available TCH/Hs

Description

C11507 represents mean number of TCH/Hs available for use in the observed cell.

Measurement Point

Counter increments when database is queried periodically.

C11508 Description

Average number of unavailable TCH/Hs

Definition

C11507 represents mean number of TCH/Hs unavailable for use in the observed cell.

Measurement Point

Counter increments when database is queried periodically.

C11509 Definition

Maximum number of busy TCH/Hs

Description

C11509 represents maximum number of seize TCH/Hs in a cell.

Page 280: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

264 Confidential and Proprietary Information of ZTE CORPORATION

C11509 increments if MS occupies TCH/H successfully. Similarly if MS does not occupy TCH/H successfully, counter C11509 decrements by 1. C11509 updates according to number of seize TCH/Hs in cell at the time of measurement query. Before MS releases TCH/H in a cell, C11509 updates number of seize TCH/Hs in a cell. This is done because seizure of TCH/Hs in a cell of previous measurement cycle is taken into account.

Measurement Point

C11509 increments at three measurement points:

If maximum busy TCH/Hs exceeds the record after successful TCH/H seizure.

If maximum busy TCH/Hs exceeds the record after successful TCH/H release.

If maximum busy TCH/Hs exceeds during measurement cycle.

C11510 Definition

Mean number of busy TCH/Hs

Description

C11510 represents mean number of seize TCH/Hs channels in a cell, during measurement cycle.

In BSC, the seize number of TCH/Hs at cyclic measurement report shows number of busy TCH/Hs.

Measurement Point

C11510 updates seize number of TCH/H after successful TCH/H seizure and release. C11510 increments and measurement report is send to OMC-R.

C11511 Definition

Total TCH/H busy time

Description

C11511 represents total seizure time of each TCH/H in a cell. Total number of seize TCH/H in a cell shows TCH/H traffic in that cell.

There are three measurement points:

C11511 increments when MS obtains TCH/H successfully.

C11511 increments when MS releases TCH/H.

C11511 increments at time of measurement of TCH/H

Page 281: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 15 - Resource Availability Measurement

Confidential and Proprietary Information of ZTE CORPORATION 265

Calculation formula

(Current time – Time of previous measurement) × (Number of MS which are occupying channels)

C11512 Definition

Total TCH/H congestion time

Description

C11512 represents total TCH/H congestion time. At this time cell can not apply for TCH/H. C11512 marks congestion when MS fails to occupy TCH/Hs. Similarly C11512 clears congestion mark when MS successes to occupy TCH/Hs. Initially C11512 sets congestion mark during TCH/H application. C11512 obtains congestion time at this period by subtracting the previous record congestion time from current time. Sum of congestion time of each calculation is the total TCH/H congestion time.

Measurement Point

There are three measurement points:

Counter C11512 increments if counter C11512 sets congestion mark before MS attempts to occupy TCH/H.

Counter C11512 increments if counter C11512 sets congestion mark before MS release TCH/H.

Counter C11512 increments if counter C11512 sets congestion mark at the time of measurement query.

C11513 Definition

Mean number of available TCH/Fs

Description

C11513 represents mean number of TCH/Hs available for use in the observed cell.

Measurement Point

Counter increments when database is queried periodically.

C11514 Definition

Average number of unavailable TCH/Fs

Page 282: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

266 Confidential and Proprietary Information of ZTE CORPORATION

Description

C11514 represents mean number of TCH/Hs unavailable for use in the observed cell.

Measurement Point

Counter increments when database is queried periodically.

C11515 Definition

Maximum number of busy TCH/Fs

Description

C11515 represents maximum number of seize TCH/Fs in a cell.

C11515 increments if MS occupies TCH/F successfully. Similarly if MS does not occupy TCH/F successfully, counter C11515 decrements by 1. C11509 updates according to number of seize TCH/Hs in cell at the time of measurement query. Before MS releases TCH/F in a cell, C11509 updates number of seize TCH/Fs in a cell. This is done because seizure of TCH/Fs in a cell of previous measurement cycle is taken into account.

Measurement Point

C11515 increments at three measurement points:

If maximum busy TCH/Fs exceeds the record after successful TCH/F seizure.

If maximum busy TCH/Fs exceeds the record after successful TCH/F release.

If maximum busy TCH/Fs exceeds during measurement cycle.

C11516 Definition

Mean number of busy TCH/Fs

Description

C11516 represents mean number of seize TCH/F channels in a cell during measurement cycle. In BSC, seize number of TCH/Fs at cyclic measurement report indicates the average busy quantity.

Measurement Point

C11516 updates seize quantity after successful TCH/F seizure and release. C11516 increments and sends it to cyclic measurement report in OMC-R database.

Page 283: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 15 - Resource Availability Measurement

Confidential and Proprietary Information of ZTE CORPORATION 267

C11517 Definition

Total TCH/F busy time

Description

C11517 represents total seize time of TCH/F in a cell. C11517 shows TCH/F traffic in a cell

Measurement Point

C11517 increments when:

MS obtains TCH/F channels successfully

MS releases TCH/F channel

Database query

Calculation Formula

(Current time – time point of previous measurement) × (Number of MS which are occupying TCH/F channels)

C11517 obtains measurement value by accumulating each measurement value.

After each time of accumulation, current time replaces time of previous measurement.

C11517 increments by 1 at TCH/F seizure

C11517 decrements by 1 at TCH/F release

FIGURE 13 shows calculation procedure of measurement of total busy time of TCH/F channel.

C11518 Definition

Total TCH/F congestion time

Description

C11518 records the congestion time of TCH/F.

Calculation Formula

Congestion time = Current Time – Previous Congestion Time

Measurement Point

C11518 increments when:

If congestion mark is set before MS attempts to seize TCH/F

If congestion mark is set before MS release TCH/F

If it sets congestion mark is set at the time of measurement query

Page 284: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

268 Confidential and Proprietary Information of ZTE CORPORATION

C11519 Definition

Total number of TRXs

Description

C11519 represents total number of TRXs configured in a cell.

Measurement Point

Querying OMC-R database during periodical measurement report

C11520 Definition

Total number of healthy TRXs

Description

C11520 represents total TRXs which are working properly in a cell.

Measurement Point

Querying OMC-R database during periodical measurement report

C11521 Definition

Seizure duration of reserved full rate channel

Description

Total time of using reserved channel in cell, which reflects traffic of reserved channels.

There are three measurement points:

C11521 increments after obtaining the reserve channel resources.

C11521increments after releasing reserve channel resources.

C11521 increments during regular measurement.

Calculation Formula

(Current time – time point of last measurement) X number of MSs occupying reserved channels.

Page 285: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 269

C h a p t e r 16

Sub Cell Measurement

This chapter covers the following topics:

Sub Cell Counters

Sub Cell Counters It is important to note here that all the sub cells are part of the dual frequency cell. These counters are for the sub cells of dual frequency cells.

Sub Cell Measurement involves counters that provide statistics such as:

Radio Resources of second sub cell

Handover between first sub cell and second sub cell

Resource Utilization of second sub cell

TAB L E 24 - S U B C E L L C O U N T E R S

Counter No. Definition

C12001 Total number of available TCH/Fs in the second sub cell

C12002 Total number of unavailable TCH/Fs in the second sub cell

C12003 Total number of available TCH/Hs in the second sub cell

C12004 Total number of unavailable TCH/Hs in the second sub cell

C12005 Number of handover attempts from the first sub cell to the second sub cell

C12006 Number of handover execution from the first sub cell to the second sub cell

C12007 Number of successful handover from the first sub cell to the second sub cell

C12008 Number of handover attempts from the second sub cell to the first sub cell

C12009 Number of handover execution from the second sub cell to the first sub cell

Page 286: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

270 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Definition

C12010 Number of successful handover from the second sub cell to the first sub cell

C12011 Number of handover attempts in the second sub cell

C12012 Number of handover execution in the second sub cell

C12013 Number of successful handover in the second sub cell

C12014 Number of outgoing inter-cell handover attempts of the second sub cell

C12015 Number of outgoing inter-cell handover execution of the second sub cell

C12016 Number of successful outgoing inter-cell handover of the second sub cell

C12017 Handover attempts due to uplink receiving strength of the full rate second sub cell

C12018 Handover attempts due to downlink receiving strength of the full rate second sub cell

C12019 Handover attempts due to uplink quality of the full rate second sub cell

C12020 Handover attempts due to downlink quality of the full rate second sub cell

C12021 Handover attempts due to PBGT of the full rate second sub cell

C12022 Handover attempts due to traffic of the full rate second sub cell

C12023 Handover attempts due to other causes of the full rate second sub cell

C12024 Handover attempts due to uplink receiving strength of the half rate second sub cell

C12025 Handover attempts due to downlink receiving strength of the half rate second sub cell

C12026 Handover attempts due to uplink quality of the half rate second sub cell

C12027 Handover attempts due to downlink quality of the half rate second sub cell

C12028 Handover attempts due to PBGT of the half rate second sub cell

C12029 Handover attempts due to traffic of the half rate second sub cell

C12030 Handover attempts due to other causes of the half rate second sub cell

C12031 Number of attempts of TCH/F seizure of the second sub cell (used for assignment)

C12032 Number of successful TCH/F seizure of the second sub cell (used for assignment)

C12033 Number of failed TCH/F seizure of the second sub cell (used for assignment)

C12034 Number of attempts of TCH/F seizure of the second sub cell (used for handover)

C12035 Number of successful TCH/F seizure of the second sub cell (used for handover)

Page 287: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 271

Counter No. Definition

C12036 Number of failed TCH/F seizure of the second sub cell (used for handover)

C12037 Number of attempts of TCH/H seizure of the second sub cell (used for assignment)

C12038 Number of successful TCH/H seizure of the second sub cell (used for assignment)

C12039 Number of failed TCH/H seizure of the second sub cell (used for assignment)

C12040 Number of attempts of TCH/H seizure of the second sub cell (used for handover)

C12041 Number of successful TCH/H seizure of the second sub cell (used for handover)

C12042 Number of failed TCH/H seizure of the second sub cell (used for handover)

C12043 Total number of TCH/F call drops in the second sub cell

C12044 Total number of TCH/H call drops in the second sub cell

C12045 Total TCH/F busy time in the second sub cell

C12046 Total TCH/H busy time in the second sub cell

Sub Cell Counters Explanation C12001 Definition

Total number of available TCH/Fs in the second sub cell

Description

Total number of TCH/Fs those are available for use in the second sub cell.

Measurement Point

Querying the database in periodic measurement reporting

C12002 Definition

Total number of unavailable TCH/Fs in the second sub cell

Description

Total number of TCH/Fs those are unavailable for use in the second sub cell.

Measurement Point

Querying the database in periodic measurement reporting

Page 288: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

272 Confidential and Proprietary Information of ZTE CORPORATION

C12003 Definition

Total number of available TCH/Hs in the second sub cell

Description

Total number of TCH/Hs those are available for use in the second sub cell.

Measurement Point

Querying the database in periodic measurement reporting

C12004 Definition

Total number of unavailable TCH/Hs in the second sub cell

Description

Total number of TCH/Hs those are available for use in the second sub cell.

Measurement Point

Querying the database in periodic measurement reporting

C12005 Definition

Number of handover attempts from the first sub cell to the second sub cell

Description

Number of handover attempts from the first sub cell to the second sub cell in the dual-frequency cell

Measurement Point

Counting upon successful request for the channel of the second sub cell due to the handover attempt from the first sub cell to the second sub cell in the dual-frequency cell

C12006 Definition

Number of handover execution from the first sub cell to the second sub cell

Page 289: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 273

Description

During handover from first sub cell to second sub cell, successful activation of the destination channel in the second sub cell indicates normal handover execution.

Measurement Point

Counting upon receiving channel activation response from second sub cell, during handover from the first sub cell to the second sub cell.

C12007 Definition

Number of successful handover from the first sub cell to the second sub cell

Description

During handover from the first sub cell to the second sub cell, reception of Assignment Complete message on destination channel indicates successful handover.

Measurement Point

C12007 increments at reception of assignment complete message from second sub cell, during handover from the first sub cell to the second sub cell.

C12008 Definition

Number of handover attempts from the second sub cell to the first sub cell

Description

Number of handover attempts from the second sub cell to the first sub cell in the dual-frequency cell

Measurement Point

C12008 increments at successful channel request due to the handover attempt from the second sub cell to the first sub cell.

C12009 Definition

Number of handover execution from the second sub cell to the first sub cell

Page 290: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

274 Confidential and Proprietary Information of ZTE CORPORATION

Description

During handover from the first sub cell to the second sub, successful channel activation in the second sub cell indicates normal handover execution.

Measurement Point

C12009 increments at reception of channel activation message from second sub cell.

C12010 Definition

Number of successful handover from the second sub cell to the first sub cell

Description

During handover from second sub cell to the first sub cell in, reception of Assignment Complete message on the destination channel indicates successful handover.

Measurement Point

C12010 increments at reception of Assignment Complete message on the destination channel of the first sub cell.

C12011 Definition

Number of handover attempts in the second sub cell

Description

Number of internal handover attempts in the second sub cell in the dual-frequency cell

Measurement Point

Counting upon successful channel application for internal handover attempt in the second sub cell in the dual-frequency cell

C12012 Definition

Number of handover execution in the second sub cell

Description

During internal handover in the second sub cell, successful activation of the destination channel indicates normal handover execution.

Page 291: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 275

Measurement Point

C12012 increments at activation response of destination channel during internal handover in the second sub cell.

C12013 Definition

Number of successful handover in the second sub cell

Description

During internal handover in the second sub cell, reception of Assignment Complete message from the MS on the destination channel indicates successful handover.

Measurement Point

C12013 increments at reception of Assignment Complete message on destination channel during internal handover in the second sub cell.

C12014 Definition

Number of outgoing inter-cell handover attempts of the second sub cell

Description

Number of handover attempts from the second sub cell to the BSC cell.

Measurement Point

C12014 increments upon handover attempt to the destination cell in the BSC from the second sub cell.

C12015 Definition

Number of outgoing inter-cell handover execution of the second sub cell

Description

Number of handover execution from the second sub cell in the dual-frequency cell to the BSC cell.

Measurement Point

Counting upon sending of resource availability message to the former channel instance after the destination channel is activated.

Page 292: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

276 Confidential and Proprietary Information of ZTE CORPORATION

C12016 Definition

Number of successful outgoing inter-cell handover of the second sub cell

Description

Number of successful handover outs from second sub to the BSC cell. Reception of Handover Complete message on the destination channel indicates successful handover. After that, the destination channel instance notifies the source instance for successful handover out through the SPS_PNPN_HO_COM message.

Measurement Point

Counting when the source channel instance receives the SPS_PNPN_HO_COM message, in handover from the second sub cell in the dual-frequency cell to the BSC cell

C12017 Definition

Handover attempts due to uplink receiving strength of the full rate second sub cell

Description

This counter represents the number of handover attempts on the TCH/F channel of the second sub cell due to uplink receiving strength. Handover cases such as intra-BSC inter-cell handover and external handover. It provides frequency information about handover from serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

C12017 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12018 Definition

Handover attempts due to downlink receiving strength of the full rate second sub cell

Description

This counter represents the number of handovers on the TCH/F channel of the second sub cell due to downlink receiving strength. Handover includes intra-BSC inter-cell handover and external handover. It provides frequency information about handover from serving cell’s second sub cell due to downlink receiving strength.

Page 293: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 277

Measurement Point

C12018 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12019 Definition

Handover attempts due to uplink quality of the full rate second sub cell

Description

This counter represents the number of handovers due to uplink quality on the TCH/F channel of the second sub cell. Handover includes intra-BSC inter-cell handover and external handover. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

C12019 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12020 Definition

Handover attempts due to downlink quality of the full rate second sub cell

Description

This counter represents the number of handovers due to downlink quality on the TCH/F channel of the second sub cell. Handover includes intra-BSC inter-cell handover and external handover. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

C12020 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12021 Definition

Handover attempts due to PBGT of the full rate second sub cell

Description

This counter represents the number of handovers due to PBGT on the TCH/F channel of the second sub cell. Handover includes intra-BSC

Page 294: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

278 Confidential and Proprietary Information of ZTE CORPORATION

inter-cell handover and external handover. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

C12021 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12022 Definition

Handover attempts due to traffic of the full rate second sub cell

Description

This counter represents the number of handovers due to traffic on the TCH/F channel of the second sub cell. Handover includes intra-BSC inter-cell handover and external handover. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

C12022 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12023 Handover attempts due to other causes of the full rate second sub cell

Description

This counter represents the number of handovers due to other causes on the TCH/F channel of the second sub cell. Handover includes intra-BSC inter-cell handover and external handover. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

C12023 increments at reception of Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) due to uplink receiving strength.

C12024 Definition

Handover attempts due to uplink receiving strength of the half rate second sub cell

Page 295: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 279

Description

This counter represents the number of handovers (including intra-BSC inter-cell handover and external handover), which is due to uplink receiving strength, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to uplink receiving strength, then measurement increments.

C12025 Definition

Handover attempts due to downlink receiving strength of the half rate second sub cell

Description

This index represents the number of handover (including intra-BSC inter-cell handover and external handover), which is due to uplink receiving strength, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to uplink receiving strength, then measurement increments.

C12026 Definition

Handover attempts due to uplink quality of the half rate second sub cell

Description

This index represents the number of handover (including intra-BSC inter-cell handover and external handover), which is due to uplink receiving strength, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Page 296: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

280 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to uplink receiving strength, then measurement increments.

C12027 Definition

Handover attempts due to downlink quality of the half rate second sub cell

Description

This index represents the number of handover (including intra-BSC inter-cell handover and external handover), which is due to uplink receiving strength, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to uplink receiving strength, then measurement increments.

C12028 Definition

Handover attempts due to PBGT of the half rate second sub cell

Description

This index represents the number of handover (including intra-BSC inter-cell handover and external handover), which is due to uplink receiving strength, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to uplink receiving strength, then measurement increments.

Page 297: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 281

C12029 Definition

Handover attempts due to traffic of the half rate second sub cell

Description

This index represents the number of handover (including intra-BSC inter-cell handover and external handover), which is due to uplink receiving strength, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to uplink receiving strength, then measurement increments.

C12030 Definition

Handover attempts due to other causes of the half rate second sub cell

Description

This index represents the number of handover (including intra-BSC inter-cell handover and external handover), which is due to causes except for those of 12024~12029, on the TCH/F channel of the second sub cell. It helps to provide frequency information of handover of the serving cell’s second sub cell due to uplink receiving strength.

Measurement Point

In the second sub cell, if the current channel is TCH/F channel, and after being judged by handover algorithm, Radio Apply (intra-BSC inter-cell handover) or HANDOVER REQUIRED (external handover) are transmitted due to causes except for those of 12024~12029, then measurement increments.

C12031 Definition

Number of attempts of TCH/F seizure of the second sub cell (used for assignment)

Description

Number of attempts of TCH/F seizure of the second sub cell (used for assignment), including cases of successful and failed seizure

Page 298: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

282 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C12031 increments, when TCH/F activates successfully in the second sub cell or fails.

C12032 Definition

Number of successful TCH/F seizure of the second sub cell (used for assignment)

Description

Number of successful TCH/F seizure of the second sub cell (used for assignment)

Measurement Point

C12032 increments when applying for the TCH/F channel succeeds.

C12033 Definition

Number of failed TCH/F seizure of the second sub cell (used for assignment)

Description

Number of failed TCH/F seizure of the second sub cell (used for assignment)

Measurement Point

C12033 increments when applying for the TCH/F channel fails.

C12034 Definition

Number of attempts of TCH/F seizure of the second sub cell (used for handover)

Description

Number of attempts of TCH/F seizure of the second sub cell (used for handover), including cases of successful and failed seizure

Measurement Point

C12034 increments at TCH/F activation in the second sub cell becomes successful or fails.

Page 299: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 283

C12035 Definition

Number of successful TCH/F seizure of the second sub-cell (used for handover)

Description

Number of successful TCH/F seizure of the second sub-cell (used for handover)

Measurement Point

Counter increments when applying for TCH/F channel of the second sub cell succeeds.

C12036 Definition

Number of failed TCH/F seizure of the second sub cell (used for handover)

Description

Number of failed TCH/F seizure of the second sub cell (used for handover)

Measurement Point

Counter increments when applying for TCH/F channel of the second sub cell fails.

C12037 Definition

Number of attempts of TCH/H seizure of the second sub cell (used for assignment)

Description

Number of attempts of TCH/H seizure of the second sub cell (used for assignment), including cases of successful and failed seizure

Measurement Point

C12037 increments if TCH/H activation successes or fails.

C12038 Definition

Number of successful TCH/H seizure of the second sub cell (used for assignment)

Page 300: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

284 Confidential and Proprietary Information of ZTE CORPORATION

Description

Number of successful TCH/H seizure of the second sub cell (used for assignment)

Measurement Point

C12038 increments when applying for TCH/H of the second sub cell succeeds.

C12039 Definition

Number of failed TCH/H seizure of the second sub cell (used for assignment)

Description

Number of failed TCH/H seizure of the second sub cell (used for assignment)

Measurement Point

C12039 increments when applying for TCH/H of the second sub cell fails.

C12040 Definition

Number of attempts of TCH/H seizure of the second sub cell (used for handover)

Description

Number of attempts of TCH/H seizure of the second sub cell (used for handover), including cases of successful and failed seizure

Measurement Point

C12040 increments if TCH/H activation successes or fails in the second sub cell.

C12041 Definition

Number of successful TCH/H seizure of the second sub cell (used for handover)

Description

Number of successful TCH/H seizure of the second sub cell (used for handover)

Page 301: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter16 - Sub Cell Measurement

Confidential and Proprietary Information of ZTE CORPORATION 285

Measurement Point

C12041 increments when applying for TCH/H of the second sub cell succeeds.

C12042 Definition

Number of failed TCH/H seizure of the second sub cell (used for handover)

Description

Number of failed TCH/H seizure of the second sub cell (used for handover)

Measurement Point

C12042 increments when applying for TCH/H of the second sub cell fails.

C12043 Definition

Total number of TCH/F call drop in the second sub cell

Description

Number of voice call drop on the TCH/F of the second sub cell, involving call drop due to intra-cell handover failure (T3107 timer overflow), inter-cell handover failure (T3103 timer overflow), handover out failure (T8 timer overflow), wireless link failure or LAPD interrupt. Refer to the description of Counters C00037 ~ C00039 and Counter C00050 in Section TRX Service Counters Measurement.

Measurement Point

Counting upon receivingT3107 timer overflow, T3103 timer overflow, T8 timer overflow, wireless link failure or LAPD interrupt message on the TCH/F voice channel of the second sub cell

C12044 Definition

Total number of TCH/H call drops in the second sub cell

Description

Number of voice call drop on the TCH/H of the second sub cell, involving call drop due to intra-cell handover failure (T3107 timer overflow), inter-cell handover failure (T3103 timer overflow), handover out failure (T8 timer overflow), wireless link failure or LAPD interrupt. Refer to the description of Counters C00037 ~ C00039 and Counter C00050 in TRX Service Counters Measurement.

Page 302: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

286 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counting upon receivingT3107 timer overflow, T3103 timer overflow, T8 timer overflow, wireless link failure or LAPD interrupt message on the TCH/F voice channel of the second sub cell

C12045 Definition

Total TCH/F busy time in the second sub cell

Description

Total time in which TCH/Fs in the second sub cell are utilized

Measurement Point

There are three measurement points:

Accumulation upon success obtainment of TCH/F resource of the second sub cell

Accumulation upon release of TCH/F resource of the second sub cell

Accumulation of timed measurement obtainment calculation

Measurement formula:

(Current time – Time point of the last measurement) × Number of the MSs which are occupying channels.

C12046 Definition

Total TCH/H busy time in the second sub cell

Measurement Point

There are three measurement points:

Accumulation upon success obtainment of TCH/H resource of the second sub cell

Accumulation upon release of TCH/H resource of the second sub cell

Accumulation of time measurement obtainment calculation

Measurement formula

(Current time – Time point of the last measurement) × Number of the MSs which are occupying channels.

Page 303: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 287

C h a p t e r 17

A-interface Signal Measurement

This chapter includes counters that provide signaling statistics over the A-interface. This Chapter covers following topics:

BSSAP Message Counters

BSSMAP Message Counters

BSSAP Message Counters Signaling over A-interface is in the form of Base Station Subsystem Application Part (BSSAP) messages. BSSAP itself can be separated into the base station subsystem management application part (BSSMAP) and the direct transfer application part (DTAP).

BSSMAP include all messages exchanges between BSC and MSC that are actually processed by the BSC. Examples are Paging, Handover and Reset messages.

DTAP messages comprise all messages exchanged between subsystem of the NSS and MS. DTAP messages are transparent for the BSS. DTAP messages carry Call Control (CC) and Mobility Management (MM) information.

Table 25 represents BSSAP message counters over A-interface.

TAB L E 25 B S S AP M E S S AG E C O U N T E R S

Counter No. Definition

C20101 Number of uplink DTAP messages

C20102 Number of downlink DTAP messages

C20103 Number of uplink BSSMAP messages

C20104 Number of downlink BSSMAP messages

Page 304: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

288 Confidential and Proprietary Information of ZTE CORPORATION

C20105 Number of downlink BSSMAP messages received with error.

BSSAP Message Counters Explanation C20101 Definition

Number of uplink DTAP messages

Description

Counter ‘C20101’ represents the number of DTAP messages that MS sends to MSC.

Measurement Point

Counter ‘C20101’ increments when first DTAP message reaches to the BSC. BSC then passes it to the MSC.

C20102 Definition

Number of downlink DTAP messages

Description

Counter ‘C20102’ represents the number of DTAP messages that MSC sends to the MS.

Measurement Point

Counter ‘C20102’ increments when first DTAP message reaches to the BSC. BSC then passes it to the MS.

C20103 Definition

Number of uplink BSSMAP messages

Description

Counter ‘C20103’ represents the number of BSSMAP messages that BSC sends to the MSC. BSC sends BSSMAP messages along with the following messages:

Connection Request Message

Data Request Message

Unit Data Request Message

Measurement Point

Counter ‘C20103’ increments when BSC sends first BSSMAP message to the MSC.

Page 305: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 17 - A-interface Signal Measurement

Confidential and Proprietary Information of ZTE CORPORATION 289

C20104 Definition

Number of downlink BSSMAP messages

Description

Counter ‘C20104’ represents the number of BSSMAP messages that MSC sends to the BSC. MSC sends BSSMAP messages along with the following messages;

Connection Indication Message

Connection Confirm Message

Data Indication Message

Unit Data Indication Message

Measurement Point

Counter ‘C20104’ increments when BSC receives the first BSSMAP message from the MSC.

C20105 Definition

Number of downlink BSSMAP messages received with error

Description

Counter ‘C20105’ represents the number of BSSMAP messages that MSC sends to BSC, contains error. Error such as:

L3 message length is 0

Miss match between BSSMAP and L3 messages length

Decoding error

Message type error.

Measurement Point

Counter ‘C20105’ increments when BSC receives the first BSSMAP message containing error.

BSSMAP Message Counters BSSMAP include all the messages exchanges between BSC and MSC that are actually processed by the BSC. Examples are Paging, Handover and Reset messages.

Table 26 represents all the BSSMAP Message Counters over the A-interface.

Page 306: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

290 Confidential and Proprietary Information of ZTE CORPORATION

TAB L E 26 B S S M AP M E S S AG E C O U N T E R S

Counter No. Counter Definition

C20001 Number of ASSIGNMENT REQUEST messages

C20002 Number of ASSIGNMENT COMPLETE messages

C20003 Number of ASSIGNMENT FAILURE messages

C20004 Number of HANDOVER REQUEST messages

C20005 Number of HANDOVER REQUIRED messages

C20006 Number of HANDOVER COMMAND messages

C20007 Number of HANDOVER REQUEST ACK messages

C20008 Number of HANDOVER COMPLETE messages

C20009 Number of HANDOVER FAILURE messages

C20010 Number of HANDOVER PERFORMED messages

C20011 Number of HANDOVER REQUIRED REJECT messages

C20012 Number of HANDOVER DETECT messages

C20013 Number of CLEAR COMMAND messages

C20014 Number of CLEAR COMPLETE messages

C20015 Number of CLEAR REQUEST messages

C20016 Number of SAPI “N” REJECT messages

C20017 Number of uplink CONFUSION messages

C20018 Number of downlink CONFUSION messages

C20019 Number of SUSPEND messages

C20020 Number of RESUME messages

C20021 Number of MSC INVOKE TRACE messages

C20022 Number of BSS INVOKE TRACE messages

C20023 Number of CHANGE CIRCUIT messages

C20024 Number of CHANGE CIRCUIT ACKNOWLEDGE messages

C20025 Number of CIPHER MODE COMMAND messages

C20026 Number of CIPHER MODE COMPLETE messages

C20027 Number of CIPHER MODE REJECT messages

C20028 Number of CLASSMARK UPDATE messages

C20029 Number of QUEUING INDICATION messages

C20030 Number of COMPLETE LAYER 3 INFORMATION messages

C20031 Number of CLASSMARK REQUEST messages

C20032 Number of HANDOVER CANDIDATE ENQUIRE messages

C20033 Number of HANDOVER CANDIDATE RESPONSE messages

C20034 Number of uplink RESET messages

C20035 Number of downlink RESET messages

C20036 Number of uplink RESET ACKNOWLEDGE messages

Page 307: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 17 - A-interface Signal Measurement

Confidential and Proprietary Information of ZTE CORPORATION 291

Counter No. Counter Definition

C20037 Number of downlink RESET ACKNOWLEDGE messages

C20038 Number of uplink OVERLOAD messages

C20039 Number of downlink OVERLOAD messages

C20040 Number of uplink RESET CIRCUIT messages

C20041 Number of downlink RESET CIRCUIT messages

C20042 Number of uplink RESET CIRCUIT ACK messages

C20043 Number of downlink RESET CIRCUIT ACK messages

C20044 Number of uplink BLOCK messages

C20045 Number of downlink BLOCK messages

C20046 Number of uplink BLOCKING ACKNOWLEDGE messages

C20047 Number of downlink BLOCKING ACKNOWLEDGE messages

C20048 Number of uplink UNBLOCK messages

C20049 Number of downlink UNBLOCK messages

C20050 Number of uplink UNBLOCKING ACKNOWLEDGE messages

C20051 Number of downlink UNBLOCKING ACKNOWLEDGE messages

C20052 Number of uplink CIRCUIT GROUP BLOCK messages

C20053 Number of downlink CIRCUIT GROUP BLOCK messages

C20054 Number of uplink CIRCUIT GROUP BLOCKING ACKNOWLEDGE messages

C20065 Number of uplink LOAD INDICATION messages

C20066 Number of downlink LOAD INDICATION messages

Page 308: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

292 Confidential and Proprietary Information of ZTE CORPORATION

This Page is intentionally blank

Page 309: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 293

C h a p t e r 18

A- Interface Service Measurement

This chapter covers the following topics:

SMM Assignment Counters

SMM Handover Counters

SMM Call Drop Counters

SMM Assignment Counters SMM Assignment Counters provide statistics for the successful and failed assignments due to different causes, but actually processed by SMM.

Assignment Process Assignment process involves following steps:

1. MSC sends ‘Assignment Request’ message to the SMM through A-interface.

2. SMM checks the circuit status and searches database for the available circuit.

3. SMM also checks the circuit attributes such as circuit rate and voice version.

4. SMM sends ‘Assignment Request’ message to the RMM.

5. RMM sends ‘Assignment Command’ message to the MS.

6. MS sends ‘Assignment Complete’ message to MSC if MS successfully acquires the assignment.

FIGURE 20 illustrates the Assignment Process.

Page 310: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

294 Confidential and Proprietary Information of ZTE CORPORATION

F IGURE 20 - S M M AS S I G N M E N T P R O C E S S

MSC

Assignment Request

Assignment Request

Assignment Complete

Assignment Complete

MS

Assignment Command

Assignment Complete

SMMRMM

TAB L E 27 S M M AS S I G N M E N T C O U N T E R S

Counter No. Counter Definition

C20301 Number of Assignment attempts

C20302 Number of unsuccessful assignments due to Circuit block

C20303 Number of unsuccessful assignments due to Circuit Group Mismatch

C20304 Number of unsuccessful assignments due to timeout

C20305 Number of unsuccessful assignments due to the other causes.

SMM Assignment Counters Explanation C20301 Definition

Number of assignment attempts

Description

Counter ‘C20301’ represents the number of ‘Assignment Request’ messages that BSC receives from the MSC, through A-interface.

Measurement point

Counter ‘C20301’ increments when BSC receives the first ‘Assignment Request’ message from the MSC.

C20302 Definition

Number of unsuccessful assignments due to Circuit block

Description

Page 311: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 18 - A- Interface Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 295

BSC sends ‘Assignment Fail’ messages to MSC if the requested circuit is block, hence assignment fails.

Measurement point

Counter ‘C20302’ increments when BSC sends first ‘Assignment Fail’ message to MSC due to the block circuit.

C20303 Definition

Number of unsuccessful assignments due to Circuit Group Mismatch

Description

MSC sends ‘Assignment Request’ message to the BSC, through A-interface. BSC in reply sends ‘Assignment Fail’ message to the MSC if there is a mismatch between required circuit attributes and BSC configuration. Circuit attributes such as Type, Voice Version and Rate.

Measurement point

Counter ‘C20303’ increments when BSC sends the first ‘Assignment Fail’ message to the MSC due to Circuit Group Mismatch.

C20304 Definition

Number of unsuccessful assignments due to the timeout

Description

When BSC receives ‘Assignment Request’ message:

1. SMM sends ‘Assignment Request’ message to RMM

2. SMM initiates timer T1 and waits for RMM response

3. T1 expires if there is no response from RMM within specified time

4. SMM returns ‘Assignment Fail’ message to MSC.

FIGURE 21 illustrates the Assignment Failure Process within BSS.

Page 312: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

296 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 21 - AS S I G N M E N T F AI L U R E S P R O C E S S

MSCSCMRRM

Assignment Request

Assignment Request

Assignment Complete

Assignment Complete

Set T1

Stop T1

Assignment Request

Assignment RequestSet T1

Assignment FailureT1 Timeout

A

Counter ‘C20304’ represents the number of times BSC sends ‘Assignment Fail’ message to the MSC, specifically due to the timeout.

Measurement point

Counter ‘C20304’ increments when the timer T1 expires. In FIGURE 21, point ‘A’ represents the measurement point.

C20305 Definition

Number of unsuccessful assignments due to the other causes

Description

MSC sends ‘Assignment Request’ message to the BSC, through A-interface. Assignment becomes unsuccessful if message contains errors such as: voice version, rate and field error.

Measurement point

Counter ‘C20305’ increments when BSC sends the first ‘Assignment Fail’ message to the MSC due to other causes.

SMM Handover in Counters SMM Handover Counters provide statistics for the successful and failed handover due to the different causes, but are actually processed by the SMM.

Page 313: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 18 - A- Interface Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 297

SMM Handover in Process Handover-In process involves the following steps:

1. MSC sends ‘Handover Request’ message to the SMM through A-interface.

2. SMM checks the circuit status and searches database for the available circuit.

3. SMM also checks the circuit attributes such as circuit rate and voice version.

4. SMM sends ‘Handover Request’ message to the RMM.

5. RMM sends ‘Handover Command’ message to the MS.

6. MS sends ‘Handover Complete’ message all the way back to MSC if MS successfully acquires the channel.

FIGURE 22 - H AN D O V E R P R O C E S S

MSCSMMRMM

Handover Request

Handover Request

Handover Complete

Handover Complete

MS

Handover Command

Handover Complete

Table 28 represents SMM Handover Counters and their definition.

TAB L E 28 SMM H AN D O V E R C O U N T E R S

Counter No. Counter Definition

C20401 Number of handover in attempts

C20402 Number of unsuccessful handover ins due to Circuit block

C20403 Number of unsuccessful handover ins due to Circuit Group Mismatch

C20404 Number of unsuccessful handover ins due to the timeout

C20405 Number of unsuccessful handover ins due to the other causes.

Handover in Counters Explanation C20401 Definition

Number of Handover in attempts

Page 314: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

298 Confidential and Proprietary Information of ZTE CORPORATION

Description

Counter ‘C20401’ represents the number of ‘Handover Request’ messages that BSC receives from the MSC, through A-interface.

Measurement point

Counter ‘C20401’ increments when BSC receives the first ‘Handover Request’ message from the MSC.

C20402 Definition

Number of unsuccessful handover-ins due to Circuit block

Description

MSC sends ‘Handover Request’ message to BSC through A-interface. BSC searches for the required circuit in database. BSC sends ‘Handover Fail’ message to MSC, If the required circuit is blocked,

Measurement point

Counter ‘C20402’ increments when BSC sends first ‘Handover Fail’ message to MSC due to the block circuit.

C20403 Definition

Number of unsuccessful handover-ins due to Circuit Group Mismatch

Description

MSC sends ‘Handover Request’ message to the BSC, through A-interface. BSC searches for the required circuit in database. BSC sends ‘Handover Fail’ message to MSC, if there is a mismatch between required circuit attributes and BSC configuration. Circuit attributes such as Type, Voice Version and Rate.

Measurement point

Counter ‘C20403’ increments when BSC sends first ‘Handover Fail’ message to MSC due to ‘Circuit Group Mismatch’.

C20404 Definition

Number of unsuccessful handover-ins due to the timeout

Description

When BSC receives ‘Handover Request’ message:

1. SMM sends ‘Handover Request’ message to RMM

2. SMM initiates timer T4 and waits for the RMM response

Page 315: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 18 - A- Interface Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 299

3. Timer T4 expires if there is no response from RMM within the specified time

4. SMM returns ‘Handover Fail’ message to MSC.

FIGURE 23 illustrates the Handover Fail process.

FIGURE 23 - H AN D O V E R FAI L U R E P R O C E S S

MSCSCMRRM

handover Request

handover Request

Handover Complete

Handover Complete

Set T4

Stop T4

Handover Request

Handover RequestSet T4

Handover FailureT4 Timeout

A

Counter ‘C20404’ represents the number of ‘Handover Fail’ messages that BSC sends to MSC due to timeout.

Measurement Point

Counter increments when the timer T4 expires. In FIGURE 23, point ‘A’ represents the measurement point.

C20405 Definition

Number of unsuccessful handover-ins due to the other causes

Description

MSC sends ‘Handover Request’ message to the BSC, through A-interface. Handover fails if message contains errors such as: voice version, rate and field error.

Measurement Point

Counter ‘C20405’ increments when BSC sends the first ‘Handover Fail’ message to MSC due to the other causes.

Page 316: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

300 Confidential and Proprietary Information of ZTE CORPORATION

SMM Call Drop Counters SMM Call Drop counters provide statistics for:

Abnormal call drops

Circuit Release requests from RMM

SCCP link disconnection

Disconnection of SMM and RMM communication

Table 29 represents all SMM Call Drop counters

TAB L E 29 S M M C AL L D R O P C O U N T E R S

Counter No. Counter Definition

C20501 Number of RMM requests for the circuit release.

C20502 Number of abnormal SCCP link disconnections

C20503 Number of call drops due to timeout

C20504 Number of call drops due the other causes

Call Drop Counters Explanation C20501 Definition

Number of RMM requests for the circuit release.

Description

RMM originates the circuit release due to poor radio link level and quality. Counter ‘C20501’ represents the number of RMM requests for circuit release.

Measurement point

Counter increments when SMM receives first ‘Clear Request’ message from the RMM.

C20502 Definition

Number of abnormal SCCP link disconnections

Description

Counter ’C20502’ represents the number of call drops due to abnormal SCCP link disconnections.

Page 317: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 18 - A- Interface Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 301

Measurement point

Counter increments when SMM receives first ‘SCCP DISCONNECT INDICATION’ message.

C20503 Definition

Number of call drops due to timeout

Description

Timer initiates when SMM request RMM services. Call drops if RMM do not respond within the specific time. Following cases may result in a call drop.

SMM and RMM periodically shake hand with each other to refresh the link. SMM sends status query to the RMM. SMM sets the timer (T12) and waits for the RMM response. Timer (T12) expires if SMM do not receive any response from RMM within the specific time, hence call drops.

SMM send ‘Assignment Request’ message to RMM. SMM sets the timer (T1) and waits for RMM response. Timer (T1) expires if SMM do not receive any response from RMM, hence call drops.

SMM sends ‘Handover Request’ message to RMM, during the handover-out process. SMM sets the timer (T8) and waits for RMM response. Timer (T8) expires if SMM do not receive any response from RMM, hence call drops.

SMM sends ‘Handover Request’ message to RMM, during the handover-in process. SMM sets the timer (T4) and waits for RMM response. Timer (T4) expires if SMM do not receive any response from RMM, hence call drops.

Counter ‘C20503’ represents the number of call drops due to the timeout.

Measurement Point

Counter ‘C20503’ increments when:

T12 expires

T1 expires

T8 expires.

T4 expires

C20504 Definition

Number of call drops due the other causes

Description

Call Drops due to the following causes:

Page 318: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

302 Confidential and Proprietary Information of ZTE CORPORATION

SMM receives ‘Handover Complete’ message containing errors

SMM receives ‘Assignment Fail’ or ‘Handover Fail’ message due to no return of the old channel.

SMM receives ‘Change Circuit’ message appears, but circuit application fails.

SMM receives ‘Assignment Complete’ message containing errors

Measurement Point

Counter ‘C20504’ increments when SMM receives:

‘Handover Complete’ message containing errors.

‘Assignment Fail’ or ‘Handover Fail’ message due to no return of the old channel.

‘Change Circuit’ message, but circuit application fails.

‘Assignment Complete’ message containing errors.

Page 319: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 303

C h a p t e r 19

SCCP Connection Measurement

This Chapter covers the following topics:

SCCP Connection Counters

SCCP Connection Counters SCCP Connection Counters provide statistics for SCCP messages that are used to setup an SCCP connection. At the beginning of an SCCP connection setup, either MSC or BSC can initiate the setup process. The SCCP link setup process is shown in FIGURE 24.

FIGURE 24 - SCCP C O N N E C T I O N S E T U P

5(b)

Connection Request

A

Connection Confirm

B

MSCBSC

5(a)

Connection Request

E

Connection Confirm

F

MSCBSC

BSC may be the first one to send ‘Connection Request’ message to MSC, as shown in Fig 5(a). MSC in reply may send ‘Connection Confirm’ message as an acknowledgement. Similar process occurs if MSC initiates the SCCP connection setup, as illustrated in FIGURE 24 (b).

SCCP Message Counters are listed in Table 30.

Page 320: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

304 Confidential and Proprietary Information of ZTE CORPORATION

TAB L E 30 SCCP C O N N E C T I O N C O U N T E R S

Counter No. Counter Definition

C20201 Number of BSC originated SCCP Connection attempts

C20202 Number of BSC originated successful SCCP Connections

C20203 Number of BSC originated unsuccessful SCCP Connections due to timeout

C20204 Number of negative replies for SCCP connection request

C20205 Number of MSC originated SCCP Connection Requests

C20206 Number of MSC originated successful SCCP Connections

SCCP Connection Counters Explanation C20201 Definition

Number of BSC originated SCCP Connection attempts

Description

BSC sends ‘Connection Request’ message to establish an SCCP connection with MSC. Counter ‘C20201’ represents number of ‘Connection Request’ messages that BSC sends to MSC.

Measurement point

Counter ‘C20201’ increments when BSC sends first ‘Connection Request’ message to the MSC (Point ‘A’ in FIGURE 24).

C20202 Definition

Number of BSC originated successful SCCP Connections

Description

BSC sends ‘Connection Request’ message to establish an SCCP connection with MSC. MSC in reply sends ‘Connection Confirm’ message to the BSC. Counter ‘C20202’ represents the number of ‘Connection Confirm’ messages that BSC receives from MSC.

Measurement point

Counter ‘C20202’ increments when BSC receives first ‘Connection Request’ message from the MSC (point ‘B’ in FIGURE 24).

C20203 Definition

Number of BSC originated unsuccessful SCCP Connections due to timeout

Page 321: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter19 - A- Interface Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 305

Description

BSC sends ‘Connection Request’ message to establish an SCCP connection with MSC. On the same time, Timer ‘T9105’ is set on and BSC waits for the MSC response. Timer ‘T9105’ expires if MSC do not respond within the specific time. As a result an SCCP connection setup fails.

Counter ‘C20203’ represents the number of unsuccessful BSC attempts to establish an SCCP connection with the MSC due to timeout.

Measurement point

Counter ‘C20203’ increments at the point when Timer ‘T9105’ expires (Point F in FIGURE 25).

FIGURE 25 - T I M E D E L AY S C E N AR I O I N SCCP C O N N E C T I O N S E T U P

Connection Request

MSCBSC

Set T9105

T 9105 TimeoutF

C20204 Definition

Number of negative replies for SCCP connection request

Description

Counter ‘C20204’ represents the number of ‘Connection Refused’ messages that BSC receives from MSC, in reply to the SCCP Connection Request.

Measurement point

Counter ‘C20204’ increments when BSC receives first ‘Connection Refused’ message from MSC (Point ‘G’ in FIGURE 25).

Page 322: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

306 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 26 - SCCP ‘C O N N E C T I O N R E F U S E D ’ F R O M MSC

Connection Request

Connection Refused

MSCBSC

F

G

C20205 Definition

Number of MSC originated SCCP Connection Requests

Description

MSC sends ‘Connection Request’ message to establish an SCCP connection with BSC. Counter ‘C20205’ represents the number of ‘Connection Request’ messages that BSC receives from MSC.

Measurement point

Counter ‘C20205’ increments when BSC receives first ‘Connection Request’ message to the MSC (Point ‘E’ in FIGURE 24).

C20206 Definition

Number of MSC originated successful SCCP Connections

Description

BSC sends ‘Connection Confirm’ messages to MSC, if SCCP connection setup becomes successful.

Measurement point

Counter ‘C20206’ increments when BSC sends first ‘Connection Confirm’ message to the MSC (point ‘F’ in FIGURE 24).

Page 323: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 307

C h a p t e r 20

Terrestrial Resources Measurement

This chapter covers the following topic:

Trunk Circuit Counters

Trunk Circuit Counters Trunk Circuit counters provide statistics for the all the BSC trunk circuits. Table 31 lists all the Trunk Circuit Counters.

TAB L E 31 TR U N K C I R C U I T C O U N T E R S

Counter No. Counter Definition

C20601 Mean number of available trunk circuits

C20602 Mean number of unavailable trunk circuits

C20603 Maximum number of busy trunk circuits

C20604 Total busy time of trunk circuit

C20605 Total congestion time of trunk circuit

Trunk Circuit Counters Explanation C20601 Definition

Mean number of available trunk circuits

Description

Counter ‘C20601’ represents the mean number of trunk circuits that are normally available to use.

Page 324: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

308 Confidential and Proprietary Information of ZTE CORPORATION

Measurement point

System calculates the mean number of available trunk circuits by timely checking the circuit status and querying the circuit database.

C20602 Definition

Mean number of unavailable trunk circuits

Description

Counter ‘C20602’ represents the mean number of trunk circuits that are normally unavailable to use. Unavailable trunk circuits can be;

Occupied

Blocked

Measurement point

System calculates the mean number of available trunk circuits by timely checking the circuit status and querying the circuit database.

C20603 Definition

Maximum number of busy trunk circuits

Description

Counter ‘C20603’ represents the maximum number of occupied trunk circuits during measurement cycle. System keeps the record of occupied trunk circuit quantity during the measurement cycle. If the occupied trunk circuit quantity exceeds the value of this counter, system records the new value in this counter.

Measurement point

Counter ‘C20603’ increments on three time instances;

When system successfully occupies the circuit

Before system has to releases the circuit

During the time measurement cycle

C20604 Definition

Total busy time of the trunk circuits

Explanation

Counter ‘C20604’ represents the total busy time of all the trunk circuit during measurement cycle.

System represents the busy status of the trunk circuit in a separate variable ‘n’. Each time system occupies the circuit, ‘n’ increments by

Page 325: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 20 - A- Interface Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 309

one. Each time system releases the trunk circuit, ‘n’ decrements by one.

The measurement calculation process is shown in FIGURE 27.

FIGURE 27 - TO T AL B U S Y T I M E F O R T H E TR U N K C I R C U I T S

Measurement circle

Trunk circuit occupy or release

Occupation time + = ( current time -previous record time) ×

1 added to or reduced from the ‘n’

Trunk circuit occupy or release

Same as the above calculation

Measurement value Same as the above calculation

Time Time

n

n = Number of times for the System to occupy the trunk circuit

Previous record time = current time

Calculation Formula

Total occupied Time= (Current Time – Previous Represents Time) * n

Previous Represents Time = Current time.

Where:

n: number of times system occupies the trunk circuits.

Current Time: Time instance at which system occupies the trunk circuits.

Previous Represents Time: Time instance at which system occupied the trunk circuit last time.

(Current Time - Previous Represents Time): occupied time for the trunk circuits.

Another way to calculate the Total occupied time is to accumulate the occupied period at discrete time instances, during the single measurement cycle.

Measurement point

Total occupied time is calculated on three time instances;

When system successfully occupies the trunk circuit

Before system has to releases the trunk circuit

During the time measurement cycle

C20605 Definition

Total congestion time of trunk circuit

Page 326: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

310 Confidential and Proprietary Information of ZTE CORPORATION

Description

Counter ‘C20605’ represents the total time for which trunk circuit can not be applied. When system fails to occupy the trunk circuit, congestion mark is set on. System represents the congestion time once the congestion mark is set on the trunk circuit in database. System clears the congestion mark once the trunk circuit is released.

Measurement formula

If congestion mark is set on, the Total Congestion Time at this point can be calculated as follows.

Total Congestion Time= (Release Time – Previous record congestion Time)

Where;

Release Time: Time instance at which system releases the trunk circuit.

Previous Record Time: Time instance at which system applies for the trunk circuit, but it unavailable due to congestion.

Another way to calculate the Total Congestion Time is to accumulate the congestion period at discrete time instances, during the single measurement cycle.

Measurement point

Total Congestion Time is calculated on three time instances;

When system successfully occupies the trunk circuit

Before system has to releases the trunk circuit

During the time measurement cycle

Page 327: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 311

C h a p t e r 21

TRX LAPD Link Measurement

This chapter covers the following topic:

LAPD Link Counters

LAPD Link Counters LAPD Link Counters provide statistics for the TRX LAPD board, which transfers the signaling messages to its contiguous layers. LAPD link is the data link layer, lies at second level in the hierarchy. System represents the statistics when LAPD board sends or receives the messages.

Table 32 represents all the LAPD link counters.

TAB L E 32 L AP D L I N K C O U N T E R S

Counter No. Counter Definition

C30001 Number of packets transfers from MP to application layer.

C30002 Number of I-frames LAPD link sends through Abis-Interface

C30003 Number of I-frames LAPD link receives through Abis-Interface

C30004 Number of packets LAPD link receives for application layer

C30005 Total number of frames TRX LAPD Link sends on the Abis-interface

C30006 Total number of frames TRX LAPD Link receives through Abis-interface

C30007 Number of lost messages due to Buffer overflow

C30008 Number of TRX LAPD Link data frame retransmissions

Page 328: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

312 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C30009 Number of data frame retransmission requests TRX LAPD Link receives

C30010 Number of successful TRX LAPD Link setups

C30011 Number of TRX LAPD Link disconnections

C30012 Number of LAPD protocol errors

C30013 Packet loss due to flow control

LAPD Link Counters Explanation C30001 Definition

Number of packets transfers from MP to application layer.

Description

LAPD link receives the signaling message from MP (application layer) and breaks it up into the packets. It then transmits all the packets on Abis-interface (Physical layer).

Measurement point

Counter ‘C30001’ increments when TRX LAPD link sends the application layer packet.

C30002 Definition

Number of I-frames LAPD link sends through Abis-Interface

Description

TRX LAPD link receives I-frame from the MP (Application Layer) and breaks it up into the packets. It then transmits all the packets on Abis-interface.

Measurement point

Counter ‘C30002’ increments when the TRX LAPD link sends I frame through Abis-interface.

C30003 Definition

Number of I-frames LAPD link receives through Abis-Interface

Page 329: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 21 - TRX LAPD Link Measurement

Confidential and Proprietary Information of ZTE CORPORATION 313

Description

TRX LAPD link receives I-frame through Abis-Interface and breaks it up into the packets. It then transmits all the packets to MP (Layer 3).

Measurement point

Counter ‘C30003’ increments when the TRX LAPD link receives I frame through Abis-interface.

C30004 Definition

Number of packets LAPD link receives for application layer

Description

LAPD link receives the signaling message from Abis-Interface (physical layer) and breaks it up into the packets. LAPD Link then transmits all the packets to MP (Application layer).

Measurement point

Counter ‘C30004’ increments when TRX LAPD link receives the message that belongs to MP (application layer).

C30005 Definition

Total number of frames TRX LAPD Link sends on the Abis-interface

Description

Counter ‘C30005’ represents the total number of frames that TRX LAPD link sends on the Abis-interface. Total number of frames includes all types of LAPD frames.

Measurement point

Counter ‘C30005’ increments when the TRX LAPD link sends first frame on the Abis-Interface.

C30006 Definition

Total number of frames TRX LAPD Link receives through Abis-interface

Description

Counter ‘C30006’ represents the total number of frames that TRX LAPD link receives from the Abis-interface. Total number of frames includes all types of LAPD frames.

Measurement point

Counter ‘C30006’ increments when the TRX LAPD link receives first frame from the Abis-Interface.

Page 330: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

314 Confidential and Proprietary Information of ZTE CORPORATION

C30007 Definition

Number of lost messages due to Buffer overflow

Description

Each TRX LAPD card contains buffer to accumulate the messages before send out. The buffer overflows if too many messages accumulate in it. As a result buffer tends to loose the messages. Counter ‘C30007’ represents the number of message loss occurs due to buffer overflow.

Measurement point

Counter ‘C30007’ increments when message loss occurs due to buffer overflow.

C30008 Definition

Number of TRX LAPD Link data frame retransmissions

Description

Counter ‘C30008” represents the number of data frames that LAPD link retransmits. Sender keeps on sending the data frames until recipient does not acknowledge the send message.

Measurement Point

Counter ‘C30008” increments when sender retransmits the data frame.

C30009 Definition

Number of data frame retransmission requests TRX LAPD Link receives

Description

Counter ‘C30009’ represents number of data frame retransmission requests, if not received correctly on the first occasion. As a result, sender retransmits the data frame and waits for an acknowledgement.

Measurement point

Counter ‘C30009’ increments when TRX LAPD link receives the retransmission request.

C30010 Definition

Number of successful TRX LAPD Link setups

Page 331: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 21 - TRX LAPD Link Measurement

Confidential and Proprietary Information of ZTE CORPORATION 315

Description

Counter ‘C30010’ represents the number of successful TRX LAPD Link establishments between the two peer entities.

Measurement point

Counter ‘C30010’ increments when the TRX LAPD link is established between the two peer entities.

C30011 Definition

Number of TRX LAPD Link disconnections

Description

Counter ‘C30011’ represents the number of TRX LAPD link disconnections between two peer entities.

Measurement point

Counter ‘C30011’ increments when BSC detects the TRX LAPD link disconnection.

C30012 Definition

Number of LAPD protocol errors

Description

Counter ‘C30012’ represents the number of LAPD messages containing errors, received through Abis-interface.

Measurement point

Counter ‘C30012’ increments when LAPD link receives the message about error in LAPD protocol through Abis-interface.

C30013 Definition

Packet loss due to flow control

Description

Counter ‘C30013’ represents the number of packet loss due to the flow control. Flow control is to reduce the load on CPU.

Measurement point

Counter ‘C30013’ increments when packet loss due to flow control.

Page 332: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

316 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 333: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 317

C h a p t e r 22

Processor Load Measurement

Processor Load Measurement provide statistics for CPU load, memory consumption, service load and file system load in SMM and RMM. The statistical units of measurement are RMM and SMM. Measurement usually occurs after every five minutes.

This chapter covers the following topics:

RMM Load Counters

Service Load Counters

Usability Measurement Counters

SMM Load Counters

File System Load Counters

RMM Load Counters RMM Load Counters provide statistics such as CPU load and memory consumption for RMM.

Table 33 lists RMM Load Counters

TAB L E 33 R M M L O AD C O U N T E R S

Counter No. Definition

C90101 Average load of the processor

C90102 Peak value of the processor load

C90103 Average value of the memory resource utilization

C90104 Peak value of the memory resource utilization

Page 334: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

318 Confidential and Proprietary Information of ZTE CORPORATION

RMM Load Counters Explanation C90101 Definition

Average load of the processor

Description

System collects the samples of the CPU load for RMM, after every ten seconds. System then calculates the average of the collected sample values (after every five minutes). This average value represents the average load on the processor.

Counter ‘C90101’ represents the average CPU load for RMM. System regularly updates the counter every five minutes.

Measurement Point

Counter ‘C90101’ increments when system calculates the average value after every five minutes.

C90102 Definition

Peak value of the processor load

Description

System collects the samples of the CPU load for RMM after every ten seconds. System then calculates the average of the collected sample values (after every five minutes). System compares the calculated average value with the maximum value of the CPU load on the represents. If the average value exceeds the previous represents value, system represents the new peak value in the counter.

Counter ‘C90102’ represents the peak value of the CPU load for RMM.

Measurement Point

Counter ‘C90102’ increments when system selects the new peak value of the CPU load for RMM.

C90103 Definition

Average value of the memory resource utilization

Description

Not in use

Measurement Point

Not in use

Page 335: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter22 - Processor Load Measurement

Confidential and Proprietary Information of ZTE CORPORATION 319

C90104 Definition

Peak value of the memory resource utilization

Description

Not in use

Measurement Point

Not in use

Service Load Counter Service Load Counters provide statistics for the number of service calls for SMM and RMM. Only single counter below identifies the service load on RMM and SMM.

Table 34 represents the Service Load Counter.

TAB L E 34 S E R V I C E L O AD C O U N T E R

Counter No. Definition

C90201 Number of Voice calls service for SMM and RMM.

Service Load Counter Explanation C90201 Definition

Number of Voice Calls service for SMM and RMM.

Description

Counter ‘C90201’ represents the number of voice calls that SMM and RMM receives.

Voice calls service for SMM at AIS instance:

SMM receives ‘Establish Indication’ message from RMM.

SMM receives ‘Handover Request’ message through A-interface.

Service calls for RMM at RMS instance:

RMM receives ‘Assignment Required’ message from BTS.

RMM receives ‘Handover Request’ message from one or more RMM.

Page 336: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

320 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C90201 increments when:

SMM receives ‘Establish Indication’ and ‘Handover Request’ messages.

RMM receives ‘Assignment Required’ and ‘Handover Request’ messages.

Usability Measurement Counter Only single counter in the Table 35 below represents the usability measurement counter.

TAB L E 35 U S AB I L I T Y M E AS U R E M E N T C O U N T E R

Counter No. Definition

C90301 Number of unit restarts

Usability Measurement Counter Explanation C90301 Definition

Number of unit restarts

Description

Counter ‘C90301’ represents the number of times for unit to restart.

Measurement Point

Counter ‘C90301’ increments when system receives HDLC disconnection message.

SMM Load Counters SMM Load Counters provide statistics for CPU load and memory consumption for SMM. Description of the following counters is same as ‘RMM Load Counters’. The only difference is that the following counters provide statistics for SMM.

Table 36 below lists all the SMM load counters.

Page 337: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter22 - Processor Load Measurement

Confidential and Proprietary Information of ZTE CORPORATION 321

TAB L E 36 S M M L O AD C O U N T E R S

Counter No. Definition

C90401 Average load of the processor

C90402 Peak value of the processor load

C90403 Average value of the memory resource utilization

C90404 Peak value of the memory resource utilization

SMM Load Counters Explanation Refer to Section ‘RMM Load Counters’.

File System Load Counters File System Load Counters provide statistics for the system’s read or write frequency on the hard disk for both RMM and SMM. These counters also represent the alarm file and performance measurement file.

TAB L E 37 F I L E S Y S T E M L O AD C O U N T E R S

Counter No. Definition

C90501 Number of file opening

C90502 Number of failed file opening

C90503 Number of file reading

C90504 Number of failed file reading

C90505 Number of file bytes read

C90506 Number of file writing

C90507 Number of failed file writing

C90508 Number of file bytes written

C90509 Number of file closing

C90510 Number of failed file closing

C90511 Number of hard disk goes into the dormant state.

Page 338: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

322 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 339: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 323

C h a p t e r 23

Q3 Module Measurement

This chapter covers the following topics:

Q3 Module Measurement Counters.

Q3 Module Counters Q3 module measurement is an analogy for BSC measurement. Statistics involve assignment, handover and CPU load. The statistics is mainly for RMM. For the SMM, the statistics only involves the CPU load.

Table 38 lists all the Q3 Module Measurement Counters

TAB L E 38 Q3 M O D U L E M E AS U R E M E N T C O U N T E R S

Counter No. Counter Definition

C11801 Number of attempts for immediate assignment.

C11802 Number of successful channel allocations

C11803 Number of successful handovers (intra-cell)

C11804 Number of unsuccessful handovers (intra-cell)

C11805 Number of successful handovers (intra-BSC handover)

C11806 Number of successful handovers due to better uplink quality (inter-cell handovers).

C11807 Number of successful handovers due to better uplink strength (inter-cell handovers).

C11808 Number of successful handovers due to better downlink quality (inter-cell handovers).

Page 340: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

324 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Counter Definition

C11809 Number of successful handovers due to better downlink strength (inter-cell handovers).

C11810 Number of successful handovers (inter-cell) due to large TA.

C11811 Number of successful handovers due to the better target cell (inter-cell handovers).

C11812 Number of successfully handovers due to the OAM interference (inter-cell handovers).

C11813 Number of handovers due to locating retry (inter-cell handover)

C11814 Number of return of the old channel due to handover failure (inter-cell handovers).

C11815 Number of call losses in case of internal handover

C11816 Average load of the processor

C11817 Peak value of the processor load

C11818 Time instance at which CPU load meets or exceeds the peak value

C11819 Time instance at which CPU load meets or exceeds the peak value

Q3 Module Counters Explanation C11801 Definition

Number of attempts for immediate assignment

Description

Counter ‘C11801’ represents the number of RMM attempts for an immediate assignment, when BSC receives ‘Channel Required’ message from BTS.

Measurement Point

Counter ‘C11801’ increments when BSC receives ‘Channel Required’ message from BTS.

C11802 Definition

Number of successful channel allocations

Description

When RMM receives ‘Establish Indication’ message from BTS, it indicates that BSC successfully allocates the channel. Counter ‘C11801’ represents the number of successes for BSC in allocating the channel.

Page 341: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 23 - Q3 Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 325

Measurement Point

Counter ‘C11801’ increments when RMM receives ‘Establish Indication’ message.

C11803 Definition

Number of successful handovers (intra-cell)

Description

In case of successful handover (intra-cell), MS sends ‘Assignment Complete’ message to MSC. Reception of ‘Assignment Complete’ message on the new channel indicates that the handover is successful. FIGURE 28 illustrates the successful intra-cell handover process.

Counter ‘C11802’ represents the number of successful intra-cell handovers

Measurement Point

Counter ‘C11802’ increments when BSC receives ‘Assignment Complete’ message from the MS.

FIGURE 28 - S U C C E S S F U L I N T R A C E L L H AN D O V E R P R O C E S S

RMM

Assignment Command

Assignment Complete(New channel)

MS

C11804 Definition

Number of unsuccessful handovers (intra-cell)

Description

When the handover (intra-cell) fails, MS sends ‘Assignment Fail’ message on the old channel to MSC. FIGURE 29 illustrates the unsuccessful intra-cell handover process.

Counter ‘C11804’ represents the number of unsuccessful intra-cell handovers.

Measurement Point

Counter ‘C11804’ increments when BSC receives ‘Assignment Fail’ message from the MS.

Page 342: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

326 Confidential and Proprietary Information of ZTE CORPORATION

F IGURE 29 - I N T R A-C E L L S H AN D O V E R F I L U R E P R O C E S S

RMM

Assignment Command

Assignment Failure(Old channel)

MS

C11805 Definition

Number of successful handovers (intra-BSC handover)

Description

When BSC successfully handovers the MS to another cell, it receives ‘Handover Complete’ message from the MS. MS sends ‘Handover Complete’ message to the BSC, on the channel assigned to MS in the new cell. FIGURE 30 illustrates the successful inter-cell handover process.

Counter ‘C11805’ represents the number of successful inter-cell handovers

Measurement Point

Counter ‘C11805’ increments when BSC receives ‘Handover Complete’ message from the MS.

FIGURE 30 - S U C C E S S F U L I N T E R -C E L L H AN D O V E R P R O C E S S

RMM

Handover Command

Handover Complete(New channel)

MS

Page 343: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 23 - Q3 Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 327

C11806 Definition

Number of successful handovers due to better uplink quality (inter-cell handovers)

Description

Counter ‘C11806’ represents the number of successful inter-cell handovers to the target cell. Cause of handover is the better uplink quality in the target cell.

Measurement Point

Counter ‘C11806’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

C11807 Definition

Number of successful handovers due to better uplink strength (inter-cell handovers)

Description

Counter ‘C11807’ represents the number of successful inter-cell handovers to the target cell. Cause of handover is the better uplink strength in the target cell.

Measurement Point

Counter ‘C11807’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

C11808 Definition

Number of successful handovers due to better downlink quality (inter-cell handovers)

Description

Counter ‘C11808’ represents the number of successful inter-cell handovers to the target cell. Cause of handover is the better downlink quality in the target cell.

Measurement Point

Counter ‘C11808’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

Page 344: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

328 Confidential and Proprietary Information of ZTE CORPORATION

C11809 Definition

Number of successful handovers due to better downlink strength (inter-cell handovers)

Description

Counter ‘C11809’ represents the number of successful inter-cell handovers to the target cell. Cause for handover is the better downlink strength in the target cell.

Measurement Point

Counter ‘C11809’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

C11810 Definition

Number of successful handovers (inter-cell) due to large TA

Description

Counter ‘C11810’ represents the number of successfully inter-cell handovers to the target cell. Cause for handover is the large distance of MS with the BTS in the serving cell. At the large distance MS may not receive desired signal strength, therefore handover occurs.

Measurement Point

Counter ‘C11810’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

C11811 Definition

Number of successful handovers due to the better target cell (inter-cell handovers).

Description

Counter ‘C11811’ represents the number of successful inter-cell handovers to the target cell. Cause for handover is the better signal strength in the target cell.

Measurement Point

Counter increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

Page 345: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 23 - Q3 Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 329

C11812 Definition

Number of successful handovers due to the OAM interference (inter-cell handovers)

Description

Counter ‘C11812’ represents the number of successful inter-cell handovers to the target cell. Cause for handover is the OAM interference. Handover occurs due to operation and maintenance causes.

Measurement Point

Counter ‘C11812’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

C11813 Definition

Numbers of successful handovers due to locating retry (inter-cell handover)

Description

Counter ‘C11813’ represents the number of successful inter-cell handovers to the target cell. Cause for handover is the locating retry.

Measurement Point

Counter ‘C11813’ increments when BSC receives ‘Handover Complete’ message from MS on the new channel.

C11814 Definition

Number of returns of the old channel due to handover failure (inter-cell handovers)

Description

Counter ‘C11814’ represents the number of BSC fails to handover the MS to the target cell. MS sends ‘Handover Fail’ message on the old channel to BSC, if handover fails. FIGURE 31 illustrates the inter-cell handover failure process.

Measurement Point

Counter ‘C11814’ increments when BSC receives ‘Handover Fail’ message from MS on the old channel.

Page 346: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

330 Confidential and Proprietary Information of ZTE CORPORATION

F IGURE 31 - I N T E R -C E L L H AN D O V E R F AI L U R E P R O C E S S

RMM

Handover Command

Handover Failure(Old channel)

MS

C11815 Definition

Number of call losses in case of internal handover

Description

Call loss occurs if BSC do not receive the following messages within specified time:

‘Assignment Complete’ message on the new channel or ‘Assignment Fail’ message on the old channel in case of intra-cell handover.

‘Handover Complete’ message on the new channel or ‘Handover Fail’ message on the old channel in case of intra-BSC handover.

Measurement Point

Counter ‘C11815’ increments when RMM receives the T3107 overflow and T3103 overflow messages.

C11816 Definition

Average load of the processor

Description

System collects the samples of the CPU load for RMM, after every ten seconds. System calculates the average of the collected sample values after every five minutes. This average value represents the average load on the processor.

Counter ‘C11816’ represents the average CPU load for RMM. System regularly updates the counter every five minutes.

Measurement Point

Counter ‘C11816’ increments when system calculates the average value after every five minutes.

Page 347: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 23 - Q3 Module Measurement

Confidential and Proprietary Information of ZTE CORPORATION 331

Calculation Formula

C11816 = C90101.

C11817 Definition

Peak value of the processor load

Description

System collects the samples of the CPU load for RMM after every ten seconds. System then calculates the average of the collected sample values (after every five minutes). System compares the calculated average value with the maximum value of the CPU load on the record. If the average value exceeds the previous represents value, system represents the new peak value in the counter.

Counter ‘C11817’ represents the peak value of the CPU load for RMM.

Measurement Point

Counter ‘C11817’ increments when system selects the new peak value of the CPU load for RMM.

Calculation Formula

C11817 = C90102.

C11818 Definition

Time instance at which CPU load meets or exceeds the peak value

Description

Counter ‘C11818’ represents the time instance when CPU load meets or exceeds the peak represents value (85%).

Measurement Point

Counter ‘C11818’ increments when the CPU load meets or exceeds the peak represents value, for the first time.

C11819 Definition

Time instance at which CPU load meets or exceeds the peak value

Description

Counter ‘C11819’ represents the total time in which CPU load meets or exceeds the represents peak value (85%).

Page 348: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

332 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

During the sampling process, if CPU load meets or exceeds the peak value (85%), counter ‘C11819’ adds all the preceding time intervals.

Page 349: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 333

C h a p t e r 24

Q3 Cell and BTS Measurement

This Chapter covers the following topics:

Q3 Cell and BTS Counters

Q3 Cell and BTS Counters This chapter introduces the Q3 Cell and Q3 BTS Measurement Counters. These counters provide statistics for received signal level, received signal quality and call distance. Counters represent the measurements of all the frequency TRXs in a cell.

For the counters of Q3 cell BTS measurement, refer to Section. The counter values are sum of the corresponding values of Counters C00017 ~ C00028 by cell. For the measurement mechanisms and measurement points, refer to the corresponding counter in Section.

Table 39 lists all the Q3 Cell Measurement Counters.

TAB L E 39 Q3 C E L L M E AS U R E M E N T C O U N T E R S

Counter No. Description

C02001 Total value of each result of regular scanning of MS utilization power

C02002 Number of regular scanning and sampling of MS utilization power

C02003 Total value of each result of regular scanning of BS utilization power

C02004 Number of regular scanning and sampling of BS utilization power

C02005 Total value of each result of regular scanning of downlink signal level

C02006 Number of regular scanning and sampling of downlink signal level

C02007 Total value of each result of regular scanning of uplink signal level

C02008 Number of regular scanning and sampling of uplink signal level

C02009 Total value of each result of regular scanning of downlink signal quality

C02010 Number of regular scanning and sampling of downlink signal quality

C02011 Total value of each result of regular scanning of uplink signal quality

C02012 Number of regular scanning and sampling of uplink signal quality

Page 350: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

334 Confidential and Proprietary Information of ZTE CORPORATION

Counter No. Description

C02013 Total value of each result of call distance statistics

C02014 Number of call distance sampling

Page 351: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 335

C h a p t e r 25

Adjacent Cell Handover Measurement

This chapter introduces the measurement counters for handover between the specified cells and their adjacent cells. These counters provide statistics for both Intra-BSC handovers and MSC-controlled handovers.

This Chapter covers the following topics:

Adjacent Cell Handover Counters

Adjacent Cell Handover Counters Handover Measurement Counters provides statistics only for the selected cells. For measurement task, at the most 10 cells can be selected. Each selected cell can have up to 32 adjacent cells. These counters provide handover statistics between the selected cells and their adjacent cells. Table 40 lists all the measurement counters.

Before explanation of the counters it is necessary to understand the Intra-MSC handover and Intra-BSC handover.

Intra-MSC Handover 1. Serving BSC takes the Handover decision based on the

measurement reports from the MS.

2. Serving BSC sends ‘Handover Required’ message to MSC if handover is decided.

3. MSC sends ‘Handover Request’ message to the target BSC.

4. Target BSC sends ‘Handover Acknowledge’ to the MSC.

5. MSC sends ‘Handover Command’ to MS through the serving BSC.

6. Handovers between MS and the target BSC.

7. MS sends ‘Handover Complete’ message to the new BSC.

Page 352: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

336 Confidential and Proprietary Information of ZTE CORPORATION

8. MSC sends ‘Channel Release’ command to the old BSC.

9. Old BSC replies ‘Channel Release Acknowledge’ message to MSC.

Intra-BSC Handover 1. Serving BSC takes the Handover decision based on the

measurement reports from the MS.

2. Serving BSC sends ‘Channel Activation’ message to target BTS if handover is decided.

3. Target BTS replies ‘Channel Activation Acknowledge’ to the serving BSC.

4. BSC sends ‘Handover Command’ message to the MS through serving BTS.

5. Handovers between MS and the target BTS.

6. MS sends ‘Handover Complete’ message to the serving BSC on the new channel.

7. New BTS sends ‘Channel Release’ command to the old BTS.

8. Old BTS replies ‘Channel Release Acknowledge’ message to new BTS.

TAB L E 40 AD J AC E N T C E L L H AN D O V E R C O U N T E R S

Counter No. Counter Definition

C11101 Number of handover attempts on the adjacent cell.

C11102 Number of successful handovers from selected cell to the adjacent cell.

C11103 Number of handover attempts from adjacent cell to the selected cell.

C11104 Number of successful handovers from adjacent cell to the selected cell.

C11105 Number of handover attempts from selected cell to the adjacent cell due to better uplink quality.

C11106 Number of handover attempts from selected cell to the adjacent cell due to better downlink quality.

C11107 Number of successful handovers from selected cell to the adjacent cell due to better uplink quality.

C11108 Number of successful handovers from selected cell to the adjacent cell due to better downlink quality.

C11109 Number of handover attempts from selected cell to the adjacent cell due to better uplink strength.

C11110 Number of handover attempts from selected cell to the adjacent cell due to better downlink strength.

C11111 Number of successful handovers from selected cell to the adjacent cell due to better uplink strength.

Page 353: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 25 - Adjacent Cell Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 337

Counter No. Counter Definition

C11112 Number of successful handovers from selected cell to the adjacent cell due to better downlink strength.

C11113 Number of handover attempts from selected cell to the adjacent cell due to PBGT

C11114 Number of successful handovers from selected cell to the adjacent cell due to PBGT

C11115 Number of handover attempts from selected cell to the adjacent cell due to other factors.

Adjacent Cell Handover Counters Explanation C11101 Definition

Number of handover attempts from selected cell to the adjacent cell.

Description

Counter ‘C11101’ represents the number of serving BSC attempts to handover the MS from selected cell to the adjacent cell, whether its Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter increments in either of the following cases. Counter ‘C11101’ increments when:

Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from the serving BSC, in case of Intra-BSC handover.

C11102 Definition

Number of successful handovers from selected cell to the adjacent cell

Description

Counter ‘C11102’ represents the number of BSC successfully handovers the MS from selected cell to the adjacent cell.

Measurement Point

Counter ‘C11102’ increments in either of the following cases:

Page 354: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

338 Confidential and Proprietary Information of ZTE CORPORATION

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11103 Definition

Number of handover attempts from adjacent cell to the selected cell

Description

Counter ‘C11103’ represents the number of BSC attempts to handover the MS from adjacent cell to the selected cell, whether its Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11103’ increments in either of the following cases:

Target BSC receives ‘Handover Request’ message from MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11104 Definition

Number of successful handovers from adjacent cell to the selected cell

Description

Counter ‘C11104’ represents the number of BSC successfully handovers the MS from adjacent cell to the selected cell, whether its Intra-MSC handover or Intra-BSC handover.

Measurement Point

Counter ‘C11104’ increments in either of the following cases. Target BSC receives ‘Handover Complete’ message from MS through MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11105 Definition

Number of handover attempts from selected cell to the adjacent cell due to better uplink quality

Description

Page 355: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 25 - Adjacent Cell Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 339

Counter ‘C11105’ represents the number of BSC attempts to handover the MS from selected cell to the adjacent cell. Cause of handover is the better uplink quality in the target cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11105’ increments in either of the following cases.

Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11106 Definition

Number of handover attempts from selected cell to the adjacent cell due to better downlink quality

Description

Counter ‘C11106’ represents the number of BSC attempts to handover the MS from selected cell to the adjacent cell. Cause of handover attempt is the better downlink quality in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11106’ increments in either of the following cases. Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11107 Definition

Number of successful handovers from selected cell to the adjacent cell due to better uplink quality

Description

Counter ‘C11107’ represents the number of BSC successfully handovers the MS from selected cell to the adjacent cell. Cause of handover is the better uplink quality in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11107’ increments in either of the following cases.

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

Page 356: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

340 Confidential and Proprietary Information of ZTE CORPORATION

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11108 Definition

Number of successful handovers from selected cell to the adjacent cell due to better downlink quality

Description

Counter ‘C11108’ represents the number of BSC successfully handovers the MS from selected cell to the adjacent cell. Cause of handover is the better downlink quality in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11108’ increments in either of the following cases.

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11109 Definition

Number of handover attempts from selected cell to the adjacent cell due to better uplink strength.

Description

Counter ‘C11109’ represents the number of BSC attempts to handover the MS from selected cell to the adjacent cell. Cause of handover attempt is the better uplink strength in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11109’ increments in either of the following cases. Counter increments when:

Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11110 Definition

Page 357: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 25 - Adjacent Cell Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 341

Number of handover attempts from selected cell to the adjacent cell due to better downlink strength.

Description

Counter ‘C11110’ represents the number of BSC attempts to handover the MS from selected cell to the adjacent cell. Cause of handover attempt is the better downlink strength in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11110’ increments in either of the following cases.

Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11111 Definition

Number of successful handovers from selected cell to the adjacent cell due to better uplink strength

Description

Counter ‘C11111’ represents the number of successful handovers from selected cell to the adjacent cell. Cause for handover is the better uplink strength in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C11111’ increments in either of the following cases.

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11112 Definition

Number of successful handovers from selected cell to the adjacent cell due to better downlink strength

Description

Counter ‘C1112’ represents the number of BSC successfully handovers the MS from selected cell to the adjacent cell. Cause of handover is the better downlink strength in the adjacent cell. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Page 358: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

342 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C1112’ increments in either of the following cases.

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11113 Definition

Number of handover attempts from selected cell to the adjacent cell due to PBGT

Description

Counter ‘C1113’ represents the number of BSC attempts to handover the MS from selected cell to the adjacent cell. Cause of handover is PBGT (Intra-MSC handover or intra-BSC handover).

Measurement Point

Counter ‘C1113’ increments in either of the following cases.

Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11114 Definition

Number of successful handovers from selected cell to the adjacent cell due to PBGT

Description

Counter ‘C1114’ represents the number of BSC successfully handovers the MS from selected cell to the adjacent cell. Cause of handover is PBGT (Intra-MSC handover or intra-BSC handover).

Measurement Point

Counter ‘C1114’ increments in either of the following cases:

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

C11115 Definition

Page 359: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 25 - Adjacent Cell Handover Measurement

Confidential and Proprietary Information of ZTE CORPORATION 343

Number of handover attempts from selected cell to the adjacent cell due to other factors.

Description

Counter ‘C1115’ represents the number of BSC attempts to handover the MS from selected cell to the adjacent cell. Cause of handover is the other factors such as traffic or rapid drop. Counter represents for both types of handovers, that is, Intra-MSC handover or intra-BSC handover.

Measurement Point

Counter ‘C1115’ increments in either of the following cases.

Target BSC receives ‘Handover Required’ message from the serving BSC through MSC, in case of Intra-MSC handover.

Target BTS receives ‘Channel Activation’ message from serving BSC, in case of Intra-BSC handover.

C11116 Definition

Number of successful handovers from selected cell to the adjacent cell due to other factors

Description

Counter ‘C1116’ represents the number of BSC successfully handovers the MS from selected cell to the adjacent cell. Cause of handover is the other factors such as traffic or rapid drop.

Measurement Point

Counter ‘C1116’ increments in either of the following cases.

Old BSC receives ‘Channel Release’ message from MSC, in case of Intra-MSC handover.

New BTS receives ‘Handover Complete’ messages from MS, in case of Intra-BSC handover.

Page 360: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

344 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 361: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 345

C h a p t e r 26

Phase-3 NMS Measurement for Cell

This chapter introduces counters for phase-3 NMS – cell basic measurement and measuring points.

Such basic measurement tasks are created as required in accordance with phase three NMS. This task can be obtained from:

Basic measurement summary report

Some required statistics

Corresponding counter used for other measurement task

Phase-3 NMS Counters This measurement task performs statistics on wireless indices involving signal level, signal quality and power control. Measurement counters are listed in Table 41.

TAB L E 41 P H AS E -3 N M S C O U N T E R S

Counter N0 Definition

C80001 Number of SDCCH RF call loss

C80002 Number of paging message sending failed

C80003 Mean number of seize PDCHs

C80004 Number of paging messages deleted from PCH queue

C80005 Number of normal increases of MS power due to uplink signal level.

C80006 Number of rapid increase of mobile station power due to uplink signal level.

C80007 Number of normal increases of MS power due to uplink signal quality.

C80008 Number of rapid increase of mobile station power due to uplink signal quality.

Page 362: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

346 Confidential and Proprietary Information of ZTE CORPORATION

Counter N0 Definition

C80009 Number of normal decrease of MS power due to up link signal level.

C80010 Number of rapid decrease of MS power due to up link signal level.

C80011 Number of normal decrease of MS power due to up link signal quality.

C80012 Number of rapid decrease of MS power due to up link signal quality.

C80013 Number of normal increases of BS power due to down link signal level.

C80014 Number of rapid increases of BS power due to down link signal level

C80015 Number of normal increases of BS power due to down link signal quality.

C80016 Number of rapid increases of BS power due to down link signal quality.

C80017 Number of normal decrease of BS power due to down link signal level.

C80018 Number of rapid decrease of BS power due to down link signal level.

C80019 Number of normal decrease of BS power due to down link signal quality.

C80020 Number of normal decrease of BS power due to down link signal quality.

C80021 Total value of each result of regular scanning of MS utilization power

C80022 Number of regular scanning and sampling of MS utilization power

C80023 Total value of each result of regular scanning of BS utilization power

C80024 Number of regular scanning and sampling of BS utilization power

C80025 Sum of uplink receiving strength of wireless channel

C80026 Sampling number of uplink receiving strength of wireless channel

C80027 Sum of downlink receiving strength of wireless channel

C80028 Number of downlink receiving strength samples of wireless channel

C80029 Sum of uplink quality levels of wireless channel

C80030 Number of uplink quality samples of wireless channel

C80031 Sum of downlink quality levels of wireless channel

C80032 Number of downlink quality samples of wireless channel

C80033 Number of handover out request failure due to unavailable Intra-MSC wireless resource

Page 363: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 26 - Phase-3 NMS Measurement for Cell

Confidential and Proprietary Information of ZTE CORPORATION 347

Counter N0 Definition

C80034 Number of failed SDCCH utilization due to carrier fault

C80035 Number of failed TCH utilization due to carrier fault

C80036 Total number of healthy TRXs

C80037 Number of outgoing dual-band handover execution

C80038 Number of successful outgoing dual-band handover

C80039 Number of incoming dual-band handover execution

C80040 Number of successful incoming dual-band handover

C11715 Number of call loss upon Intra-BSC internal handover failure

Phase-3 NMS Counters Explanation C80001 Definition

Refer C10602 Counter Definition in section Call Drop Counters Explanation

Calculation formula

C8001=C10602

C80002 Definition

Number of paging message sending failed

C80003 Definition

Mean number of seize PDCHs

Description

The number of PDCHs in database is sampled every 10 seconds. The Mean number of seize PDCHs is sum of the sampling values during a period of five minutes divided by sampling time. It reflects Mean number of seize PDCHs in the cell.

C8004 Definition

Number of paging messages deleted from PCH queue

Page 364: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

348 Confidential and Proprietary Information of ZTE CORPORATION

C80005 Definition

Number of normal increases of MS power due to uplink signal level

Description

Total number of MS power normal increase of all the TRXs in cell due to uplink signal level. Refer to C00001 Counter Definition in section Power Control Counters Explanation.

Calculation Formula

C80005= Sum of C00001 counters of all the TRXs in the cell.

C80006 Definition

Number of rapid increase of mobile station power due to uplink signal level

Description

Total number of times fast increase in MS power of all the TRXs in the cell due to uplink signal level.

Calculation Formula

C80006=Sum of C00002 counters of all the TRXs in the cell.

C80007 Definition

Number of normal increases of mobile station power due to uplink signal quality

Description

Total number of times normal increase in MS power of all the TRXs in the cell due to uplink signal quality.

Calculation Formula

C80007=Sum of C00009 counters of all the TRXs in the cell.

C80008 Definition

Number of rapid increase of mobile station power due to uplink signal quality

Page 365: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 26 - Phase-3 NMS Measurement for Cell

Confidential and Proprietary Information of ZTE CORPORATION 349

Description

Total number of times rapid increase in MS power of all the TRXs in the cell due to uplink signal quality.

Calculation Formula

C80008= Sum of C00010 counters of all the TRXs in the cell.

C80009 Definition

Number of normal decrease of mobile station power due to uplink signal level

Description

Total number of times normal decrease in MS power of all the TRXs in the cell due to uplink signal quality.

Calculation Formula

C80009=Sum of C0003 counters of all the TRXs in the cell.

C80010 Definition

Number of rapid increases of mobile station power due to uplink signal level

Description

Total number of times rapid decrease in MS power of all the TRXs in the cell due to uplink signal level.

Calculation formula

C80010=Sum of C0004 counters of all TRXs in the cell.

C80011 Definition

Number of normal decrease of mobile station power due to uplink signal quality

Description

Total number of times normal decrease in MS power of all the TRXs in the cell due to uplink signal quality.

Calculation formula

C80011= sum of C00011 counters of all the TRXs in the cell.

Page 366: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

350 Confidential and Proprietary Information of ZTE CORPORATION

C80012 Definition

Number of rapid decrease of mobile station power due to uplink signal quality

Description

Total number of times fast decrease in MS power of all the TRXs in the cell due to uplink signal quality.

Calculation formula

C80012= sum of C00012 counters of all the TRXs in the cell.

C80013 Definition

Number of normal increases of BS power due to down link signal level

Description

Total number of times normal increase in BS power of all the TRXs in the cell due to down link signal level.

Calculation formula

C80013= Sum of C00005 Counters of all the TRXs in the cell.

C80014 Definition

Number of rapid increase of BS power due to down link signal level

Description

Total number of times rapid increase in BS power of all the TRXs in the cell due to down link signal level.

Calculation formula

C80014= Sum of C00006 Counters of all the TRXs in the cell.

C80015 Definition

Number of normal increases of BS power due to down link signal quality

Page 367: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 26 - Phase-3 NMS Measurement for Cell

Confidential and Proprietary Information of ZTE CORPORATION 351

Description

Total number of times normal increase of BS power of all the TRXs in the cell due to down link signal quality.

Calculation formula

C80015= Sum of C00015 Counters of all the TRXs in the cell.

C80016 Definition

Number of rapid increase of BS power due to down link signal quality

Description

Total number of times rapid increase in BS power of all the TRXs in the cell due to down link signal quality.

Calculation formula

C80016= Sum of C00016 Counters of all the TRXs in the cell.

C80017 Definition

Number of normal decrease of BS power due to down link signal level

Description

Total number of times normal decrease in BS power of all the TRXs in the cell due to down link signal level.

Calculation formula

C80017= Sum of C00007 Counters of all the TRXs in the cell.

C80018 Definition

Number of rapid decrease of BS power due to down link signal level

Description

Total number of times rapid decrease in BS power of all the TRXs in the cell due to down link signal level.

Calculation formula

C80018= Sum of C00008 Counters of all the TRXs in the cell.

Page 368: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

352 Confidential and Proprietary Information of ZTE CORPORATION

C80019 Definition

Number of normal decrease of BS power due to down link signal quality

Description

Total number of times normal decrease in BS power of all the TRXs in the cell due to down link signal quality.

Calculation formula

C80019= Sum of C00015 Counters of all the TRXs in the cell.

C80020 Definition

Number of rapid decrease of BS power due to down link signal quality

Description

Total number of times rapid decrease of BS power of all the TRXs in the cell due to down link signal quality.

Calculation formula

C80020= Sum of C00016 Counters of all the TRXs in the cell.

C80021 Definition

Total value of each result of MS utilization power regular scanning

Description

Total value of each result of ms utilization power regular scanning on all the TRXs in a cell.

Calculation formula

C80021= Sum of C00017 Counters of all the TRXs in the cell.

C80022 Definition

Number of sampling number of MS utilization power regular scanning

Page 369: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 26 - Phase-3 NMS Measurement for Cell

Confidential and Proprietary Information of ZTE CORPORATION 353

Description

Number of sampling number of MS utilization power regular scanning on all the TRXs in the cell.

Calculation formula

C80022= Sum of C00018 Counters of all the TRXs in the cell.

C80023 Definition

Total value of each result of BS utilization power regular scanning

Description

Total value of each result of BS utilization power regular scanning on all the TRXs in the cell.

Calculation formula

C80023= Sum of C00019 Counters of all the TRXs in the cell.

C80024 Definition

Number of sampling number of BS utilization power regular scanning.

Description

Number of sampling number of BS utilization power regular scanning on all the TRXs in the cell. Refer to C00020 in section Power Control Counters Explanation.

Calculation formula

C80024= Sum of C00020 Counters of all the TRXs in the cell

C80025 Definition

Sum of uplink receiving strength of wireless channel

Calculation formula

C80025= C10710.

C80026 Definition

Number of uplink receiving strength samples

Page 370: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

354 Confidential and Proprietary Information of ZTE CORPORATION

Description

Refer to C10707 Counter Definition in section Channels Counters Explanation.

Calculation formula

C80026= C10707.

C80027 Definition

Sum of down link receiving strength of wireless channel

Description

Refer to C10714 Counter Definition in section Channels Counters Explanation.

Calculation formula

C80027= C10714.

C80028 Definition

Number of samples of downlink receiving strength

Description

Refer to C10711 Counter Definition in section Channels Counters Explanation.

Calculation formula

C80028= C10711

C80029 Definition

Sum of the uplink quality level of wireless channel

Description

Refer to C10703 Counter Definition in section Channels Counters Explanation.

Calculation formula

C80029= C10703

Page 371: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 26 - Phase-3 NMS Measurement for Cell

Confidential and Proprietary Information of ZTE CORPORATION 355

C80030 Definition

Number of uplink quality samples of wireless channel

Description

Refer to the description of Counter C10701 in Section Channels Counters Explanation.

Calculation formula

C80030 = C10701

C80031 Definition

Sum of downlink quality levels of wireless channel

Description

Refer to the description of Counter C10706 in Section Channels Counters Explanation.

Calculation formula

C80031 = C10706

C80032 Definition

Number of downlink quality samples of wireless channel

Description

Refer to the description of Counter C10704 in Section Channels Counters Explanation.

Calculation formula

C80032 = C10704

C80033 Definition

Number of handover out request failure due to unavailable Intra-MSC wireless resource

Description

Refer to the description of Counter C10707 in Section Channels Counters Explanation.

Calculation formula

C80033 = C10907

Page 372: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

356 Confidential and Proprietary Information of ZTE CORPORATION

C80034 Description

Number of failed SDCCH utilization due to carrier fault

Description

Number of carrier fault messages returned for SDCCH request from the database

Calculation formula

Counting when carrier fault message is returned for SDCCH request from the database

C80035 Definition

Number of failed TCH utilization due to carrier fault

Description

Number of carrier fault messages returned for TCH request from the database, involving TCH/F and TCH/H

Calculation formula

Counting when carrier fault message is returned for TCH request from the database

C80036 Definition

Total number of healthy TRXs

Description

Refer to the description of Counter C11520 in Resource Availability Counters Explanation

Calculation formula

C80036 = C11520

C80037 Definition

Number of outgoing dual-band handover execution

Description

Refer to the description of Counter C109120 in Resource Availability Counters Explanation.

Page 373: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 26 - Phase-3 NMS Measurement for Cell

Confidential and Proprietary Information of ZTE CORPORATION 357

Calculation formula

C80037 = C109120

C80038 Definition

Number of successful outgoing dual-band handover

Description

Refer to the description of Counter C109121 in Section Handover Counters Explanation.

Calculation formula

C80038 = C109121

C80039 Definition

Number of incoming dual-band handover execution

Description

Refer to the description of Counter C109123 in Section Handover Counters Explanation.

Calculation formula

C80039 = C109123

C80040 Definition

Number of successful incoming dual-band handover

Description

Refer to the description of Counter C109124 in Section Handover Counters Explanation.

Calculation formula

C80040 = C109124

C11715 Definition

Number of call loss upon Intra-BSC internal handover failure

Description

Call loss due to Intra-BSC intra-cell handover failure and inter-cell handover failure.

Page 374: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

358 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C11715 increments when T3103 overflow message receives for Intra-BSC inter-cell handover or the T3107 timer overflow message for Intra-BSC intra-cell handover.

Page 375: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 359

C h a p t e r 27

TCH/H Measurement

This chapter covers the following topics:

TCH/H Counters

TCH/H Counters TCH/H measurement counters provide statistics for the:

TCH/H allocation requests

TCH/H allocations

TCH/H assignment requests

TCH/H assignments

TCH/H handover requests

TCH/H handovers

There are two types of Assignment flow:

Immediate Assignment

Common Assignment

Immediate Assignment: MS originates the assignment request, which BSC has to fulfill.

Common Assignment: MSC originates the assignment command for the MS.

Page 376: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

360 Confidential and Proprietary Information of ZTE CORPORATION

FIGURE 32 and FIGURE 33 illustrates the two types of assignment flows.

FIGURE 32 - I M M I D I AT E AS S I G N M E N T F L O W

MS BTS BSC

CHL_REQ

CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

A2

IMM_ASS_CMD

IMM_ASS

SABM

EST_IND

A3

FIGURE 33 - C O M M O N AS S I G N M E N T F L O W

MS BTS BSC

B1CHL_ACT

ASS_CMD

B2ASS_CMD

ASS_CMD

SABM

EST_IND

B3

MSC

CHL_ACT_ACK

UA

ASS_COMASS_COM

ASS_COMB4

There are two types of handover flows:

Internal Handover

External Handover

FIGURE 34and FIGURE 35 illustrates the two types of assignment flows.

Page 377: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 361

Internal Handover: Handover without the involvement of MSC.

External Handover: Handover with the involvement of MSC.

FIGURE 34 - I N T E R N AL H AN D O V E R ( I N T R A-B S C H AN D O V E R )

MS BTS BSC

C1CHL_ACT

C2ASS_CMD

ASS_CMD

SABM

EST_IND

C3

MSC

CHL_ACT_ACK

UA

ASS_COMASS_COM

HO_PREFORM

MEAS_REP

MEAS_RES

FIGURE 35 - E X T E R N AL H AN D O V E R ( I N T R A-M S C H AN D O V E R )

MS BTS BSC

D1CHL_ACT

HO_REQ

D2

SABM

HO_DETECT

D3

MSC

CHL_ACT_ACK

UA

HO_COMHO_COM

HO_COM

HO_REQ_ACK

HO_DETECT

HO_ACCESS

PHY_INFO

Table 42 lists all the TCH/H measurement counters.

Page 378: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

362 Confidential and Proprietary Information of ZTE CORPORATION

TAB L E 42 T C H / H M E AS U R E M E N T C O U N T E R S

Counter No. Definition

C10401 Number of requests for TCH/H assignment (signaling)

C10402 Number of successful TCH/H assignment request (signaling)

C10403 Number of unsuccessful TCH/H assignment request (signaling)

C10404 Number of requests for TCH/H handover (signaling)

C10405 Number of successful TCH/H handover request(signaling)

C10406 Number of unsuccessful TCH/H handover request(signaling)

C10407 Number of BSC attempts to allocate TCH/H for assignment (signaling)

C10408 Number of successful TCH/H allocation for assignment (signaling)

C10409 Number of unsuccessful TCH/H allocation for assignment (signaling)

C10410 Number of BSC attempts to allocate TCH/H in case of handover (signaling)

C10411 Number of successful TCH/H allocation in case of handover (signaling)

C10412 Number of unsuccessful TCH/H allocation in case of handover (signaling)

C10413 Number of BSC attempts to assign TCH/H (signaling)

C10414 Number of successful TCH/H assignment (signaling)

C10415 Number of unsuccessful TCH/H assignment (signaling)

C10416 Number of handover attempts for TCH/H (signaling).

C10417 Number of successful TCH/H handover (Signaling)

C10418 Number of unsuccessful TCH/H handover (Signaling)

C10419 Number of BSC does not receives ‘Handover Fail’ message on the TCH/H (signaling)

C10420 Number of requests for TCH/H assignment (voice)

C10421 Number of successful TCH/H assignment request (voice)

C10422 Number of unsuccessful TCH/H assignment request (voice)

C10423 Number of requests for TCH/H handover (voice)

C10424 Number of successful TCH/H handover request(voice)

C10425 Number of unsuccessful TCH/H handover request(voice)

C10426 Number of BSC attempts to allocate TCH/H for assignment (voice version 1)

C10427 Number of successful TCH/H allocation for assignment (voice version 1)

C10428 Number of unsuccessful TCH/H allocation for assignment (voice version 1)

C10429 Number of BSC attempts to allocate TCH/H during handover (voice version 1)

C10430 Number of successful TCH/H allocation during handover (voice version 1)

C10431 Number of unsuccessful TCH/H allocation during handover (voice version 1)

Page 379: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 363

C10432 Number of BSC attempts to allocate TCH/H for assignment (voice version 2)

C10433 Number of successful TCH/H allocation for assignment (voice version 2)

C10434 Number of unsuccessful TCH/H allocation for assignment (voice version 2)

C10435 Number of BSC attempts to allocate TCH/H for handover (voice version 2)

C10436 Number of successful TCH/H allocation for handover (voice version 2)

C10437 Number of unsuccessful TCH/H allocation for handover (voice version 2)

C10438 Number of BSC attempts to allocate TCH/H for assignment (voice version 3)

C10439 Number of successful TCH/H allocation for assignment (voice version 3)

C10440 Number of unsuccessful TCH/H allocation for assignment (voice version 3)

C10441 Number of BSC attempts to allocate TCH/H for handover (voice version 3)

C10442 Number of successful TCH/H allocation for handover (voice version 3)

C10443 Number of unsuccessful TCH/H allocation for handover (voice version 3)

C10444 Number of BSC attempts to assign TCH/H (Voice)

C10445 Number of successful TCH/H assignment (Voice)

C10446 Number of unsuccessful TCH/H assignment (Voice)

C10447 Number of handover attempts for TCH/H (Voice).

C10448 Number of successful TCH/H handover (Voice)

C10449 Number of unsuccessful TCH/H handover (Voice)

C10450 Number of BSC does not receives ‘Handover Fail’ message on the TCH/H (Voice)

C10451 Number of requests for TCH/H assignment (data)

C10452 Number of successful TCH/H assignment request (data)

C10453 Number of unsuccessful TCH/H assignment request (data)

C10454 Number of requests for TCH/H handover (data)

C10455 Number of successful request for TCH/H handover (data)

C10456 Number of unsuccessful request for TCH/H handover (data)

C10457 Number of BSC attempts to allocate TCH/H for assignment (data)

C10458 Number of successful TCH/H allocation for assignment (data)

C10459 Number of unsuccessful TCH/H allocation for assignment (data)

C10460 Number of BSC attempts to allocate TCH/H for handover (data)

C10461 Number of successful TCH/H allocation for handover (data)

C10462 Number of unsuccessful TCH/H allocation for handover (data)

C10463 Number of BSC attempts to assign TCH/H (data)

C10464 Number of successful TCH/H assignment (data)

C10465 Number of unsuccessful TCH/H assignment (data)

C10466 Number of handover attempts for TCH/H (data).

C10467 Number of successful TCH/H handover (data)

Page 380: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

364 Confidential and Proprietary Information of ZTE CORPORATION

C10468 Number of unsuccessful TCH/H handover (data)

C10469 Number of BSC does not receives ‘Handover Fail’ message on the TCH/H (data)

TCHH Counters Explanation C10401 Definition

Number of requests for TCH/H assignment (signaling)

Description

Number of requests for TCH/H assignment = Number of successful request for TCH/H assignment (signaling) + Number of unsuccessful request for TCH/H assignment (signaling)

Calculation Formula

C10401 = C10402 + C10403

Measurement Point

Counter ‘C10401’ increments at the same time with counters ‘C10402’ or ‘C10403’.

C10402 Definition

Number of successful request for TCH/H assignment (signaling)

Description

Request for TCH/H assignment is successful when BSC allocates the TCH/H. This counter keeps the represents of number of successful requests for TCH/H assignment as a signaling channel.

Measurement Point

Counter ‘C10402’ increments when BSC successfully allocates the TCH/H.

C10403 Definition

Number of unsuccessful request for TCH/H assignment (signaling)

Description

Request for TCH/H assignment is unsuccessful if BSC receives negative acknowledgement in reply of channel activation request. This counter

Page 381: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 365

keeps represents of number of unsuccessful requests for TCH/H assignment as a signaling channel.

Measurement Point

Counter ‘C10403’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10404 Definition

Number of requests for TCH/H handover (signaling)

Description

Number of requests for TCH/H handover (signaling) = Number of successful request for TCH/H handover (signaling) + Number of unsuccessful request for TCH/H handover (signaling)

Calculation Formula

C10404 = C10405 + C10406

Measurement Point

Counter ‘C10404’ has the measurement point same like counter ‘C10405’ or counter ‘C10406’.

C10405 Definition

Number of successful request for TCH/H handover (signaling)

Description

Request for TCH/H handover is successful when BSC allocates the TCH/H. This counter keeps the represents of number of successful requests for TCH/H handover as a signaling channel.

Measurement Point

Counter ‘C10405’ increments when BSC successfully allocates the TCH/H.

C10406 Definition

Number of unsuccessful request for TCH/H handover (signaling)

Description

Request for TCH/H handover is unsuccessful if BSC receives negative acknowledgement in reply of channel activation request. This counter keeps the represents of number of unsuccessful requests for TCH/H handover as a signaling channel.

Measurement Point

Page 382: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

366 Confidential and Proprietary Information of ZTE CORPORATION

Counter ‘C10406’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10407 Definition

Number of BSC attempts to allocate TCH/H for assignment (signaling)

Description

Counter ‘C10407’ represents the number of BSC attempts to activate TCH/H to assign it to the MS, for the signaling purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (signaling) = Number of successful TCH/H allocation for assignment (signaling) + Number of unsuccessful TCH/H allocation for assignment (signaling)

(C10407)= C10408 + C10409

Measurement Point

Counter ‘C10407’ increments at the same time with counters ‘C10408’ or ‘C10409’.

C10408 Definition

Number of successful TCH/H allocation for assignment (signaling)

Description

Counter ‘C10408’ represents the number of BSC successfully activates the TCH/H, in order to assign it to the MS as a signaling channel.

Measurement Point

Counter ‘C10408’ increments when BSC receives ‘Channel Activation Acknowledgement’ message from BTS, in case of successful allocation of the TCH/H (A2-FIGURE 32).

C10409 Definition

Number of unsuccessful TCH/H allocation for assignment (signaling)

Description

Counter ‘C10409’ represents the number of BSC fails to activate the TCH/H, in order to assign it to the MS as a signaling channel. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Page 383: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 367

Counter ‘C10409’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10410 Definition

Number of BSC attempts to allocate TCH/H in case of handover (signaling)

Description

Counter ‘C10410’ represents the number of BSC attempts to activate TCH/H as a signaling channel in case of handover.

Calculation Formula

Number of BSC attempts to allocate TCH/H in case of handover (signaling) = Number of successful TCH/H allocation in case of handover (signaling) + Number of unsuccessful TCH/H allocation in case of handover (signaling)

C10410 = C10411 + C10412

Measurement Point

Counter ‘C10410’ increments at the same time with counters ‘C10411’ or ‘C10412’.

C10411 Definition

Number of successful TCH/H allocation in case of handover (signaling)

Description

Counter ‘C10411’ represents the number of BSC successfully activates the TCH/H as a signaling channel during the handover.

Measurement Point

Counter ‘C10411’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE 35).

C10412 Definition

Number of unsuccessful TCH/H allocation in case of handover (signaling)

Description

Counter ‘C10412’ represents the number of BSC fails to activate the TCH/H as a signaling channel during the handover.

Measurement Point

Page 384: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

368 Confidential and Proprietary Information of ZTE CORPORATION

Counter ‘C10412’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10413 Definition

Number of BSC attempts to assign TCH/H (signaling)

Description

Counter ‘C10413’ represents the number of BSC attempts to assign TCH/H to the MS as a signaling channel.

Calculation Formula

Number of BSC attempts to assign TCH/H (signaling) = Number of successful TCH/H assignment (signaling) + Number of unsuccessful TCH/H assignment (signaling)

C10413 = C10414 + C10415

Measurement Point

Counter ‘C10413’ increments at the same time with counters ‘C10414’ or ‘C10415’.

C10414 Definition

Number of successful TCH/H assignment (signaling)

Description

Counter ‘C10414’ represents the number of BSC successfully assigns the TCH/H as a signaling channel.

Measurement Point

Counter ‘C10414’ increments when BSC receives ‘Establish indication’ message from BTS (A3-FIGURE 32).

C10415 Definition

Number of unsuccessful TCH/H assignment (signaling)

Description

Counter ‘C10415’ represents the number of BSC fails to assign TCH/H to MS as a signaling channel.

Measurement Point

Counter ‘C10415’ increments when BSC receives negative acknowledgment in response to the ‘Assignment Command’ message.

C10416 Definition

Page 385: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 369

Number of handover attempts for TCH/H (signaling)

Description

Counter ‘C10416’ represents the number of BSC attempts to handover the MS on new TCH/H as a signaling channel. Handover involves both intra-cell and inter-cell handover.

Calculation Formula

Number of handover attempts for TCH/H (signaling) = Number of successful TCH/H handover (Signaling) + Number of successful TCH/H handover (Signaling)

C10416 = C10417 + C10418

Measurement Point

Counter ‘C10416’ has the measurement point same like counter ‘C10417’ or counter ‘C10418’.

C10417 Definition

Number of successful TCH/H handover (Signaling)

Description

Counter ‘C10417’ represents the number of BSC receives signaling of handover success on the new TCH/H. This counter represents for inter-cell and intra-cell handover.

Measurement Point

Counter ‘C10417” increments when BSC receives ‘Assignment Complete’ (intra-cell handover) or ‘Handover Complete’ message (inter-cell handover) on the new TCH/H. Refer to FIGURE 34-C3 and FIGURE 35-D3.

C10418 Definition

Number of unsuccessful TCH/H handover (Signaling)

Description

Counter ‘C10418’ represents the number of BSC does not receive handover success information on the new TCH/H. This counter represents for inter-cell and intra-cell handover.

Measurement Point

Counter ‘C10418” increments when BSC receives ‘Handover Fail’ message (inter-cell handover) on old TCH/H.

Page 386: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

370 Confidential and Proprietary Information of ZTE CORPORATION

C10419 Definition

Number of BSC does not receive ‘Handover Fail’ message on the TCH/H (signaling)

Description

Not Implemented

Measurement Point

Not Implemented

C10420 Definition

Number of requests for TCH/H assignment (voice)

Description

Number of requests for TCH/H assignment (voice) = Number of successful request for TCH/H assignment (voice) + Number of unsuccessful request for TCH/H assignment (voice)

Calculation Formula

C10420 = C10421 + C10422

Measurement Point

Counter ‘C10420’ increments at the same time with counters ‘C10421’ or ‘C10422’.

C10421 Definition

Number of successful request for TCH/H assignment (voice)

Description

Success of TCH/H assignment request depends upon successful TCH/H allocation. This counter keeps the represents of number of successful requests for TCH/H assignment as a voice channel.

Measurement Point

Counter ‘C10402’ increments when BSC successfully allocates the TCH/H.

C10422 Definition

Number of unsuccessful TCH/H assignment (voice)

Page 387: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 371

Description

Request for TCH/H assignment fails if BSC receives negative acknowledgement in reply of channel activation request. This counter keeps the represents of number of unsuccessful requests for TCH/H assignment as a voice channel.

Measurement Point

Counter ‘C10403’ increments when BSC receives the negative acknowledgment in response of the ‘Channel Activation’ message.

C10423 Definition

Number of requests for TCH/H handover (voice)

Description

Number of requests for TCH/H handover (voice) = Number of successful request for TCH/H handover (voice) + Number of unsuccessful request for TCH/H handover (voice)

Calculation Formula

C10423 = C10424 + C10425

Measurement Point

Counter ‘C10423’ increments at the same time with counters ‘C10424’ or ‘C10425’.

C10424 Definition

Number of successful request for TCH/H handover (voice)

Description

Request for TCH/H handover only succeeds when BSC successfully allocates the TCH/H. This counter keeps represents of number of requests for TCH/H handover as a voice channel.

Measurement Point

Counter ‘C10424’ increments when BSC successfully allocates the TCH/H.

C10425 Definition

Number of unsuccessful request for TCH/H handover (voice)

Description

Request for TCH/H handover fails when BSC receives negative acknowledgement for the channel activation request. This counter

Page 388: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

372 Confidential and Proprietary Information of ZTE CORPORATION

keeps the represents of number of unsuccessful requests for TCH/H handover as a voice channel.

Measurement Point

Counter ‘C10425’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10426 Definition

Number of BSC attempts to allocate TCH/H for assignment (voice version 1)

Description

Counter ‘C10410’ represents the number of BSC attempts to activate TCH/H as a voice channel (version 1) for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (voice version 1) = Number of successful TCH/H allocation for assignment (voice version 1) + Number of unsuccessful TCH/H allocation for assignment (voice version 1)

C10426 = C10427 + C10428

Measurement Point

Counter ‘C10426’ increments at the same time with counters ‘C10427’ or ‘C10428’.

C10427 Definition

Number of successful TCH/H allocation for assignment (voice version 1)

Description

Counter ‘C10427’ represents the number of BSC successfully activates the TCH/H as a voice channel (version 1) for the assignment purpose.

Measurement Point

Counter ‘C10427’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE 33).

C10428 Definition

Number of unsuccessful TCH/H allocation for assignment (voice version1)

Page 389: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 373

Description

Counter ‘C10412’ represents the number of BSC fails to activate the TCH/H as a voice channel (version 1) for the assignment purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10428’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10429 Definition

Number of BSC attempts to allocate TCH/H for handover (voice version 1)

Description

Counter ‘C10429’ represents the number of BSC attempts to activate TCH/H as a voice channel (version 1) for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (voice version 1) = Number of successful TCH/H allocation for handover (voice version 1) + Number of unsuccessful TCH/H allocation for handover (voice version 1)

C10429 = C10430 + C10431

Measurement Point

Counter ‘C10429’ increments at the same time with counters ‘C10430’ or ‘C10431’.

C10430 Definition

Number of successful TCH/H allocation for handover (voice version 1)

Description

Counter ‘C10430’ represents the number of BSC successfully activates the TCH/H as a voice channel (version 1) in case of handover.

Measurement Point

Counter ‘C10430’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE 35).

Page 390: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

374 Confidential and Proprietary Information of ZTE CORPORATION

C10431 Definition

Number of unsuccessful TCH/H allocation for handover (voice version1)

Description

Counter ‘C10431’ represents the number of BSC fails to activate TCH/H as a voice channel (version 1) for the handover purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10431’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10432 Definition

Number of BSC attempts to allocate TCH/H for assignment (voice version 2)

Description

Counter ‘C10432’ represents the number of BSC attempts to activate TCH/H as a voice channel (version 2) for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (voice version 2) = Number of successful TCH/H allocation assignment (voice version 2) + Number of unsuccessful TCH/H allocation assignment (voice version 2)

C10432 = C10433 + C10434

Measurement Point

Counter ‘C10432’ increments at the same time with counters ‘C10433’ or ‘C10434’.

C10433 Definition

Number of successful TCH/H allocation assignment (voice version 2)

Description

Counter ‘C10433’ represents the number of BSC successfully activates the TCH/H as a voice channel (version 2) for the assignment purpose.

Page 391: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 375

Measurement Point

Counter ‘C10433’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE 33).

C10434 Definition

Number of unsuccessful TCH/H allocation assignment (voice version 2)

Description

Counter ‘C10434’ represents the number of BSC fails to activate the TCH/H as a voice channel (version 2) for the assignment purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10434’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10435 Definition

Number of BSC attempts to allocate TCH/H for handover (voice version 2)

Description

Counter ‘C10435’ represents the number of BSC attempts to activate TCH/H as a voice channel (version 2) for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (voice version 2) = Number of successful TCH/H allocation for handover (voice version 2) + Number of unsuccessful TCH/H allocation for handover (voice version 2)

C10435 = C10436 + C10437

Measurement Point

Counter ‘C10435’ increments at the same time with counters ‘C10436’ or ‘C10437’.

C10436 Definition

Number of successful TCH/H allocation for handover (voice version 2)

Page 392: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

376 Confidential and Proprietary Information of ZTE CORPORATION

Description

Counter ‘C10430’ represents the number of BSC successfully activates the TCH/H as a voice channel (version 1) in case of handover.

Measurement Point

Counter ‘C10436’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE 35).

C10437 Definition

Number of unsuccessful TCH/H allocation for handover (voice version 2)

Description

Counter ‘C10437’ represents the number of BSC fails to activate the TCH/H as a voice channel (version 2) for the handover purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10437’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10438 Definition

Number of BSC attempts to allocate TCH/H for assignment (voice version 3)

Description

Counter ‘C10439’ represents the number of BSC attempts to activate TCH/H as a voice channel (version 3) for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (voice version 3) = Number of successful TCH/H allocation for assignment (voice version 3) + Number of unsuccessful TCH/H allocation for assignment (voice version 3)

C10438 = C10439 + C10440

Measurement Point

Counter ‘C10438’ increments at the same time with counters ‘C10439’ or ‘C10440’.

Page 393: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 377

C10439 Definition

Number of successful TCH/H allocation for assignment (voice version 3)

Description

Counter ‘C10439’ represents the number of BSC successfully activates the TCH/H as a voice channel (version 2) for the assignment purpose.

Measurement Point

Counter ‘C10439’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE 33).

C10440 Definition

Number of unsuccessful TCH/H allocation for assignment (voice version 3)

Description

Counter ‘C10440’ represents the number of BSC fails to activate the TCH/H as a voice channel (version 2) for the assignment purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10440’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10441 Definition

Number of BSC attempts to allocate TCH/H for handover (voice version 3)

Description

Counter ‘C10441’ represents the number of BSC attempts to activate TCH/H as a voice channel (version 3) for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (voice version 3) = Number of successful TCH/H allocation for handover (voice version 3) + Number of unsuccessful TCH/H allocation for handover (voice version 3)

C10441 = C10442 + C10443

Page 394: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

378 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C10441’ increments at the same time with counters ‘C10442’ or ‘C10443’.

C10442 Definition

Number of successful TCH/H allocation for handover (voice version 3)

Description

Counter ‘C10442’ represents the number of BSC successfully activates the TCH/H as a voice channel (version 3) in case of handover.

Measurement Point

Counter ‘C10442’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE 35).

C10443 Definition

Number of unsuccessful TCH/H allocation for handover (voice version 3)

Description

Counter ‘C10443’ represents the number of BSC fails to activate the TCH/H as a voice channel (version 3) for the handover purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10443’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10444 Definition

Number of BSC attempts to assign TCH/H (Voice)

Description

Counter ‘C10444’ represents the number of BSC attempts to assign TCH/H to the MS in order to carry the user speech.

Calculation Formula

Number of BSC attempts to assign TCH/H (Voice) = Number of successful TCH/H assignment (Voice) + Number of successful TCH/H assignment (Voice)

Page 395: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 379

C10444 = C10445 + C10446

Measurement Point

Counter ‘C10444’ increments at the same time with counters ‘C10445’ or ‘C10446’.

C10445 Definition

Number of successful TCH/H assignment (Voice)

Description

Counter ‘C10445’ represents the number of BSC successfully assigns TCH/H to the MS in order to carry the user speech.

Measurement Point

Counter ‘C10445’ increments when BSC receives ‘Establish indication’ message from BTS (A3-FIGURE 32).

C10446 Definition

Number of unsuccessful TCH/H assignment (Voice)

Description

Counter ‘C10446’ represents the number of BSC fails to assign TCH/H to the MS in order to carry the user speech.

Measurement Point

Counter ‘C10446’ increments when BSC receives negative acknowledgment in response to the ‘Assignment Command’ message.

C10447 Definition

Number of handover attempts for TCH/H (Voice).

Description

Counter ‘C10447’ represents the number of BSC attempts to handover the MS on new TCH/H voice channel, in case of both intra-cell and inter-cell handover.

Calculation Formula

Number of handover attempts for TCH/H (Voice) = Number of successful TCH/H handover (Voice) + Number of successful TCH/H handover (Voice)

C10447 = C10448 + C10449

Page 396: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

380 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

Counter ‘C10447’ has the measurement point same like counter ‘C10448’ or counter ‘C10449’.

C10448 Definition

Number of successful TCH/H handover (Voice)

Description

Counter ‘C10448’ represents the number of BSC receives signaling about handover success on the new TCH/H voice channel. Handover includes both inter-cell and intra-cell handover.

Measurement Point

Counter ‘C10448” increments when BSC receives ‘Assignment Complete’ (intra-cell handover) or ‘Handover Complete’ message (inter-cell handover) on the new TCH/H (Voice). Refer to FIGURE 34-C3 and FIGURE 35-D3.

C10449 Definition

Number of unsuccessful TCH/H handover (Voice)

Description

Counter ‘C10449’ represents the number of BSC fails to receive signaling about handover success on the new TCH/H voice channel. Handover includes both inter-cell and intra-cell handover.

Measurement Point

Counter ‘C10449” increments when BSC receives ‘Handover Fail’ message (inter-cell handover) on old TCH/H.

C10449 Definition

Number of BSC receives ‘Handover Fail’ message on the TCH/H (Voice)

Description

Not Implemented

Measurement Point

Not Implemented

Page 397: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 381

C10450 Definition

Number of BSC does not receives ‘Handover Fail’ message on the TCH/H (Voice)

Description

Not Implemented

Measurement Point

Not Implemented

C10451 Definition

Number of requests for TCH/H assignment (data)

Description

Number of requests for TCH/H assignment (data) = Number of successful request for TCH/H assignment (data) + Number of successful request for TCH/H assignment (data)

Calculation Formula

C10451 = C10452 + C10453

Measurement Point

Counter ‘C10451’ increments at the same time with counters ‘C10452’ or ‘C10453’.

C10452 Definition

Number of successful request for TCH/H assignment (data)

Description

Request for TCH/H assignment only succeeds when BSC successfully allocates the TCH/H. This counter keeps represents of number of requests for TCH/H assignment as a data channel.

Measurement Point

Counter ‘C10452’ increments when BSC successfully allocates the TCH/H.

C10453 Definition

Number of unsuccessful request for TCH/H assignment (data)

Page 398: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

382 Confidential and Proprietary Information of ZTE CORPORATION

Description

Request for TCH/H assignment only fails when BSC receives negative acknowledgement for the channel activation request. This counter is only to keep record of number of unsuccessful requests for TCH/H assignment as a data channel.

Measurement Point

Counter ‘C10453’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10454 Definition

Number of requests for TCH/H handover (data)

Description

Number of requests for TCH/H handover (data) = Number of successful TCH/H request for handover (data) + Number of successful TCH/H request for handover (data)

Calculation Formula

C10454 = C10455 + C10456

Measurement Point

Counter ‘C10454’ increments at the same time with counters ‘C10455’ or ‘C10456’.

C10455 Definition

Number of successful TCH/H request for handover (data)

Description

Request for TCH/H handover only succeeds when BSC successfully allocates the TCH/H. This counter keeps the represents of number of requests for TCH/H handover as a data channel.

Measurement Point

Counter ‘C10455’ increments when BSC successfully allocates the TCH/H.

C10456 Definition

Number of unsuccessful TCH/H request for handover (data)

Description

Request for TCH/H assignment only fails when BSC receives negative acknowledgement for the channel activation request. This counter is

Page 399: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 383

only to keep record of number of unsuccessful requests for TCH/H handover as a data channel.

Measurement Point

Counter ‘C10456’ increments when BSC receives the negative acknowledgment in response to the ‘Channel Activation’ message.

C10457 Definition

Number of BSC attempts to allocate TCH/H for assignment (data)

Description

Counter ‘C10457’ represents the number of BSC attempts to activate TCH/H as a data channel for the assignment purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (data) = Number of successful TCH/H allocation for assignment (data) + Number of unsuccessful TCH/H allocation for assignment (data)

C10457 = C10458 + C10459

Measurement Point

Counter ‘C10457’ increments at the same time with counters ‘C10458’ or ‘C10459’.

C10458 Definition

Number of successful TCH/H allocation for assignment (data)

Description

Counter ‘C10458’ represents the number of BSC successfully activates the TCH/H as a voice channel (data) for the assignment purpose.

Measurement Point

Counter ‘C10458’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE 33).

C10459 Definition

Number of unsuccessful TCH/H allocation for assignment (data)

Description

Counter ‘C10459’ represents the number of BSC fails to activate the TCH/H as a data channel for the assignment purpose. Causes for the failure can be:

Page 400: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

384 Confidential and Proprietary Information of ZTE CORPORATION

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10459’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10460 Definition

Number of BSC attempts to allocate TCH/H for handover (data)

Description

Counter ‘C10460’ represents the number of BSC attempts to activate TCH/H as a data channel for the handover purpose.

Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (data) = Number of successful TCH/H allocation for handover (data) + Number of unsuccessful TCH/H allocation for handover (data)

C10460 = C10461 + C10462

Measurement Point

Counter ‘C10460’ increments at the same time with counters ‘C10461’or ‘C10462’.

C10461 Definition

Number of successful TCH/H allocation for handover (data)

Description

Counter ‘C10461’ represents the number of BSC successfully activates the TCH/H as a data channel in case of handover.

Measurement Point

Counter ‘C10461’ increments when BSC receives ‘Channel Activation Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE 35).

C10462 Definition

Number of unsuccessful TCH/H allocation for handover (data)

Description

Page 401: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 385

Counter ‘C10462’ represents the number of BSC fails to activate the TCH/H as a data channel for the handover purpose. Causes for the failure can be:

Timeout for timer T9103

Overload

Function (channel) not available

Measurement Point

Counter ‘C10462’ increments when BSC receives negative acknowledgment in response to the ‘Channel Activation’ message.

C10463 Definition

Number of BSC attempts to assign TCH/H (data)

Description

Counter ‘C10463’ represents the number of BSC attempts to assign TCH/H to the MS in order to carry the user data.

Calculation Formula

Number of BSC attempts to assign TCH/H (data) = Number of successful TCH/H assignment (data) + Number of unsuccessful TCH/H assignment (data)

C10463 = C10464 + C10465

Measurement Point

Counter ‘C10463’ increments at the same time with counters ‘C10464’ or ‘C10465’.

C10464 Definition

Number of successful TCH/H assignment (data)

Description

Counter ‘C10464’ represents the number of BSC successfully assigns TCH/H to the MS in order to carry the user data.

Measurement Point

Counter ‘C10464’ increments when BSC receives ‘Establish indication’ message from BTS (A3-FIGURE 32).

C10465 Definition

Number of unsuccessful TCH/H assignment (data)

Description

Page 402: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

386 Confidential and Proprietary Information of ZTE CORPORATION

Counter ‘C10465’ represents the number of BSC fails to assign TCH/H to the MS in order to carry the user data.

Measurement Point

Counter ‘C10465’ increments when BSC receives negative acknowledgment in response to the ‘Assignment Command’ message.

C10466 Definition

Number of handover attempts for TCH/H (data).

Description

Counter ‘C10466’ represents the number of BSC attempts to handover the MS on new TCH/H data channel. Handover involves both intra-cell and inter-cell handover.

Calculation Formula

Number of handover attempts for TCH/H (data) = Number of successful TCH/H handover (data) + Number of unsuccessful TCH/H handover (data)

C10466 = C10467 + C10468

Measurement Point

Counter ‘C10466’ has the measurement point same like counter ‘C10467’ or counter ‘C10468’.

C10467 Definition

Number of successful TCH/H handover (data)

Description

Counter ‘C10467’ represents the number of BSC receives signaling about handover success on the new TCH/H data channel. Handover involves both intra-cell and inter-cell handover.

Measurement Point

Counter ‘C10467” increments when BSC receives ‘Assignment Complete’ (intra-cell handover) or ‘Handover Complete’ message (inter-cell handover) on the new TCH/H data channel. Refer to FIGURE 34-C3 and FIGURE 35-D3.

C10468 Definition

Number of unsuccessful TCH/H handover (data)

Description

Page 403: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 27 - TCH/H Measurement

Confidential and Proprietary Information of ZTE CORPORATION 387

Counter ‘C10468’ represents the number of BSC fails to receive signaling about handover success on the new TCH/H data channel. Handover involves both intra-cell and inter-cell handover.

Measurement Point

Counter ‘C10468” increments when BSC receives ‘Handover Fail’ message (inter-cell handover) on old TCH/H.

C10469 Definition

Number of BSC does not receives ‘Handover Fail’ message on the TCH/H (data)

Description

Not Implemented

Measurement Point

Not Implemented

Page 404: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

388 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 405: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 389

C h a p t e r 28

Half Rate Statistics

This chapter provides statistics for the HR related services and resources. Most counters in this chapter depend upon the sum of the other counter values from the previous chapter. Table 43 lists all the HR Measurement Counters and their definition.

This Chapter covers the following topics:

HR Measurement Counters

HR Measurement Counters TAB L E 43 H R M E AS U R E M E N T C O U N T E R S

Counter No. Definition

C11901 Total number of available TCH/Hs

C11902 Total number of unavailable TCH/Hs

C11903 Total number of requests for TCH/H (assignment)

C11904 Total number of unsuccessful TCH/H assignment request

C11905 Total number of requests for TCH/H

C11906 Total number of unsuccessful TCH/H request

C11907 Total number of successful TCH/H assignment

C11908 Total number of successful requests for TCH/H

C11909 Total number of TCH/H call drops

C11910 Total TCH/H busy time

C11911 Number of call drop occurs due to the TCH/H wireless link failure

C11912 Number of call drop occurs due to TCH/H LAPD link failure

C11913 Number of call drop occurs due to TCH/H handover failure

C11914 Maximum number of busy TCH/Hs

C11915 Mean number of busy TCH/Hs

Page 406: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

390 Confidential and Proprietary Information of ZTE CORPORATION

C11916 Total TCH/H congestion time

C11917 Total number of successful TCH/H allocation (assignment)

C11918 Total number of unsuccessful TCH/H allocation (assignment)

C11919 Total number of successful TCH/H allocation

C11920 Total number of unsuccessful TCH/H allocation

C11921 Total number of successful TCH/H assignment

C11922 Total number of unsuccessful TCH/H assignment

C11923 Total number of successful TCH/H handover

C11924 Total number of unsuccessful TCH/H handover

C11925 Total number of BSC does not receives ‘Handover Fail’ message on the TCH/H

C11926 Mean number of idle TCH/Hs with interference band as 1

C11927 Mean number of idle TCH/Hs with interference band as 2

C11928 Mean number of idle TCH/Hs with interference band as 3

C11929 Mean number of idle TCH/Hs with interference band as 4

C11930 Mean number of idle TCH/Hs with interference band as 5

C11931 Number of handover attempts on TCH/H due to better uplink receiving strength the target cell

C11932 Number of handover attempts on TCH/H due to better downlink receiving strength the target cell

C11933 Number of handover attempts on TCH/H due to uplink interference in the serving cell.

C11934 Number of handover attempts on TCH/H due to downlink interference in the serving cell.

C11935 Number of handover attempts on TCH/H due to C/I RATIO concentric circle

C11936 Number of handover attempts on TCH/H due to PBGT

C11937 Number of handover attempts on TCH/H due to large TA

C11938 Number of handover attempts on TCH/H due to better uplink quality in the target cell.

C11939 Number of handover attempts on TCH/H due to better downlink quality in the target cell.

C11940 Number of handover attempts on TCH/H due to other factors

C11941 Number of handover (intra-cell) attempts from serving TCH/F to target TCH/H

C11942 Number of handover (intra-cell) attempts from serving TCH/F to target TCH/F

C11943 Number of successful handover (intra-cell) from serving TCH/F to target TCH/F

C11944 Number of handover execution (intra-cell) from serving TCH/F to target TCH/H

C11945 Number of successful handovers (intra-cell) from serving TCH/F to target TCH/H

Page 407: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 391

C11946 Total number of TCH/H handover (intra-cell) attempts.

C11947 Number of handover execution (intra-cell) from serving TCH/H to target TCH/F

C11948 Number of successful handovers (intra-cell) between serving TCH/H to target TCH/F

C11949 Number of handover (intra-cell) execution between TCH/Hs

C11950 Number of successful handovers (intra-cell) between TCH/Hs

C11951 Number of handover (inter-cell) attempts from TCH/F to any channel in the target cell.

C11952 Number of handover (inter-cell) execution between TCH/Hs

C11953 Number of successful handovers (inter-cell) between TCH/Fs

C11954 Number of handover execution (inter-cell) from serving TCH/F to target TCH/H

C11955 Number of successful handover (inter-cell) from serving TCH/F to target TCH/H

C11956 Number of handover (inter-cell) attempts from TCH/H to any channel in the target cell.

C11957 Number of handover execution (inter-cell) from serving TCH/H to target TCH/F

C11958 Number of successful handover (inter-cell) from serving TCH/H to target TCH/F

C11959 Number of handover (inter-cell) execution between TCH/Hs

C11961 Number of DTAP messages used for point-to-point short messages on uplink FACCH/H

C11962 Number of DTAP messages used for point-to-point short messages on downlink FACCH/H

C11963 Number of DTAP messages used for point-to-point short messages on uplink SACCH/F

C11964 Number of DTAP messages used for point-to-point short messages on downlink SACCH/F

C11965 Number of DTAP messages used for point-to-point short messages on uplink SACCH/H

C11966 Number of DTAP messages used for point-to-point short messages on downlink SACCH/H

C11967 Number of successful handover from TCH full rate to TCH half rate.

C11968 Number of successful handover from TCH half rate to TCH full rate.

C11969 Number of handover from TCH full rate to TCH half rate fails.

C11970 Number of handover from TCH half rate to TCH full rate fails.

C11971 Mean number of HR channels

C11972 Maximum number of HR channels

C11973 Minimum number of HR channels

Page 408: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

392 Confidential and Proprietary Information of ZTE CORPORATION

HR Measurement Counters Explanation C11901 Definition

Total number of available TCH/Hs

Description

Refer to the description of Counter C11507 in Section Explanation of Measurement Counters

Calculation formula

C11901 = C11507

C11902 Definition

Total number of unavailable TCH/Hs

Description

Refer to the description of Counter C11508 in Section Explanation of Measurement Counters

Calculation formula

C11901 = C11508

C11903 Definition

Total number of requests for TCH/H (assignment)

Description

Counter ‘C11903’ represents the total number of requests for TCH/H assignment as a:

Signalling Channel

Voice Channel

Data Channel

Calculation formula

C11903 = C10401 + C10420 + C10451

C11904 Definition

Total number of unsuccessful TCH/H assignment request

Page 409: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 393

Description

Counter ‘C11904’ represents the total number of BSC fails to assign TCH/H as a:

Signalling Channel

Voice Channel

Data Channel

Calculation formula

C11904 = C10403 + C10422 + C10453

C11905 Definition

Total number of requests for TCH/H

Description

Counter ‘C11905’ represents the total number of TCH/H signal, voice and data requests fails in case of both assignment and handover,

Calculation formula

C11905 = C11903 + C10404+ C10423 + C10454

C11906 Definition

Total number of unsuccessful TCH/H request

Description

Counter ‘C11906’ represents the total number of request for TCH/H signal, voice and data fails in case of both assignment and handover.

Calculation formula

C11906 = C11904 + C10406+ C10425 + C10456

C11907 Definition

Total number of successful TCH/H assignment

Description

Counter ‘C11907’ represents the total number of TCH/H signal, voice and data assignments succeed in case of TCH assignment.

Calculation formula

C11907 = C10402 + C10421 + C10452

Page 410: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

394 Confidential and Proprietary Information of ZTE CORPORATION

C11908 Definition

Total number of successful requests for TCH/H

Description

Counter ‘C11908’ represents the total number of TCH/H signal, voice and data assignments succeed in case of both TCH assignment and handover.

Calculation formula

C11908 = C11907 + C10405+ C10424 + C10455

C11909 Definition

Total number of TCH/H call drops

Description

Counter ‘C11909’ represents the total number of TCH/H call drop occurs due to all the causes.

Calculation formula

C11909 = C10645

C11910 Definition

Total TCH/H busy time

Description

Counter ‘C11910’ represents the total busy time of the TCH/H.

Calculation formula

C11910 = C11511

C11911 Definition

Number of call drop occurs due to the TCH/H wireless link failure

Description

Counter ‘C11911’ represents the number of call drops for TCH signal, voice and data channels due to wireless link failure.

Calculation formula

C11911 = C10626 + C10632 + C10638

Page 411: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 395

C11912 Definition

Number of call drop occurs due to TCH/H LAPD link failure

Description

Counter ‘C11912’ represents the number of call drops for TCH signal, voice and data channels due to LAPD link failure

Calculation formula

C11912 = C10627 + C10633 + C10639

C11913 Definition

Number of call drop occurs due to TCH/H handover failure

Description

Counter ‘C11913’ represents the number of call drops for TCH signal, voice and data channels due to handover failure

Calculation formula

C11913 = C10650 + C10651 + C10652

C11914 Definition

Maximum number of busy TCH/Hs

Description

Counter ‘C11914’ represents the maximum number of seize TCH/Hs

Calculation formula

C11914 = C11509

C11915 Definition

Mean number of busy TCH/Hs

Description

Counter ‘C11915’ represents the Mean number of seize TCH/Hs

Calculation formula

C11915 = C11510

Page 412: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

396 Confidential and Proprietary Information of ZTE CORPORATION

C11916

Definition

Total TCH/H congestion time

Description

Counter ‘C11916’ represents the total congestion time of TCH/H.

Calculation formula

C11916 = C11512

C11917 Definition

Total number of successful TCH/H allocation (assignment)

Description

Counter ‘C11917’ represents the total number of BSC successfully allocates the TCH/H signal, voice (V.1, V.2 and V.3) and data channels for the assignment purpose.

Calculation formula

C11917 = C10408+ C10427+ C10433+ C10439+ C10458

C11918 Definition

Total number of unsuccessful TCH/H allocation (assignment)

Description

Counter ‘C11918’ represents the total number of BSC fails to allocate the TCH/H signal, voice (V.1, V.2 and V.3) and data channels for the assignment purpose.

Calculation formula

C11918 = C10409+ C10428+ C10434+ C10440+ C10459

C11919 Definition

Total number of successful TCH/H allocation

Description

Counter ‘C11919’ represents the total number of BSC successfully allocates the TCH/H signal, voice (V.1, V.2 and V.3) and data channels in case of both assignment and handover.

Page 413: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 397

Calculation formula

C11919 = C11917 + C10411+ C10430+ C10436+ C10442+ C10461

C11920 Definition

Total number of unsuccessful TCH/H allocation

Description

Counter ‘C11920’ represents the total number of BSC fails to allocate the TCH/H signal, voice (V.1, V.2 and V.3) and data channels in case of both assignment and handover.

Calculation formula

C11920 = C11918 + C10412+ C10431+ C10437+ C10443+ C10462

C11921 Definition

Total number of successful TCH/H assignment

Description

Counter ‘C11921’ represents the total number of BSC successfully assigns the TCH/H signal, voice and data channels.

Calculation formula

C11921 = C10414 + C10445 + C10464

C11922 Definition

Total number of unsuccessful TCH/H assignment

Description

Counter ‘C11922’ represents the total number of BSC fails to assigns the TCH/H signal, voice and data channels.

Calculation formula

C11922 = C10415 + C10446 + C10465

C11923 Definition

Total number of successful TCH/H handover

Page 414: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

398 Confidential and Proprietary Information of ZTE CORPORATION

Description

Counter ‘C1192’ represents the total number of BSC successfully handovers the MS to the new TCH/H signal, voice and data channels.

Calculation formula

C11923 = C10417 + C10448 + C10467

C11924 Definition

Total number of unsuccessful TCH/H handover

Description

Counter ‘C1124’ represents the total number of BSC fails to handover the MS to the new TCH/H signal, voice and data channels.

Calculation formula

C11924 = C10418 + C10449 + C10468

C10425 Definition

Total number of BSC does not receives ‘Handover Fail’ message on the TCH/H

Calculation formula

C11925 = C10419 + C10450 + C10469

C11926 Definition

Mean number of idle TCH/Hs with interference band as 1

Description

Refer to the description of Counter C10725 in Section Channels Counters Explanation.

Calculation formula

C11926 = C10725

C11927 Definition

Mean number of idle TCH/Hs with interference band as 2

Description

Refer to the description of Counter C10726 in Section Channels Counters Explanation.

Page 415: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 399

Calculation formula

C11927 = C10726

C11928 Definition

Mean number of idle TCH/Hs with interference band as 3

Description

Refer to the description of Counter C10727 in Section Channels Counters Explanation.

Calculation formula

C11928 = C10727

C11929 Definition

Mean number of idle TCH/Hs with interference band as 4

Description

Refer to the description of Counter C10728 in Section Channels Counters Explanation.

Calculation formula

C11929 = C10728

C11930 Definition

Mean number of idle TCH/Hs with interference band as 5

Description

Refer to the description of Counter C10729 in Section Channels Counters Explanation.

Calculation formula

C11930 = C10729

C11931 Definition

Number of handover attempts on TCH/H due to better uplink receiving strength the target cell

Calculation formula

C11931 = C10822

Page 416: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

400 Confidential and Proprietary Information of ZTE CORPORATION

C11932 Definition

Number of handover attempts on TCH/H due to better downlink receiving strength the target cell

Calculation formula

C11932 = C10823

C11933 Definition

Number of handover attempts on TCH/H due to uplink interference in the serving cell.

Description

Counter ‘C11933’ represents the number of BSC attempts to handover (External and Internal) the MS on new TCH/H. Cause of handover is the interference in the uplink channel of the serving cell.

Calculation formula

C11933 = C10824

C11934 Definition

Number of handover attempts on TCH/H due to downlink interference in the serving cell.

Description

Counter ‘C11934’ represents the number of BSC attempts to handover (External and Internal) the MS on new TCH/H. Cause of handover is the interference in the downlink channel of the serving cell.

Calculation formula

C11934 = C10825

C11935 Definition

Number of handover attempts on TCH/H due to C/I RATIO concentric circle

Description

Counter ‘C11935’ represents the number of BSC attempts to handover (External and Internal) the MS on new TCH/H. Cause of handover is large C/I RATIO in the serving TCH/H.

Calculation formula

Page 417: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 401

C11935 = C10826

C11936 Definition

Number of handover attempts on TCH/H due to PBGT

Description

Refer to the description of Counter in Section Handover Cause Counters Explanation.

Calculation formula

C11936 = C10827

C11937 Definition

Number of handover attempts on TCH/H due to large TA

Description

Refer to the description of Counter in Section Handover Cause Counters Explanation.

Calculation formula

C11937 = C10828

C11938 Definition

Number of handover attempts on TCH/H due to better uplink quality in the target cell.

Description

Refer to the description of Counter Section Handover Cause Counters Explanation.

Calculation formula

C11938 = C10839

C11939 Definition

Number of handover attempts on TCH/H due to better downlink quality in the target cell.

Description

Refer to the description of Counter Section Handover Cause Counters Explanation.

Page 418: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

402 Confidential and Proprietary Information of ZTE CORPORATION

Calculation formula

C11939 = C10840

C11940 Definition

Number of handover attempts on TCH/H due to other factors

Description

Other factors such as traffic, rapid drop and fast movement

Calculation formula

C11940 = C10831

C11941 Definition

Number of handover (intra-cell) attempts from serving TCH/F to target TCH/H

Description

Refer to the description of Counter in Section Handover Cause Counters Explanation.

Calculation formula

C11941 = C10999

C11942 Definition

Number of handover (intra-cell) attempts from serving TCH/F to target TCH/F

Description

Not Required in HR Statistics

Calculation formula

C11942 = C109100

C11943 Definition

Number of successful handover (intra-cell) from serving TCH/F to target TCH/F

Description

Not Required in HR Statistics

Page 419: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 403

Calculation formula

C11943 = C109101

C11944 Definition

Number of handover execution (intra-cell) from serving TCH/F to target TCH/H

Description

Refer to the description of Counter C109102 in Section Handover Counters Explanation.

Calculation formula

C11944 = C109102

C11945 Definition

Number of successful handover (intra-cell) from serving TCH/F to target TCH/H

Description

Refer to the description of Counter C109103 in Section Handover Counters Explanation.

Calculation formula

C11945 = C109103

C11946 Definition

Total number of TCH/H handover (intra-cell) attempts.

Description

Refer to the description of Counter C109104 in Section Handover Counters Explanation.

Calculation formula

C11946 = C109104

C11947 Definition

Number of handover execution (intra-cell) from serving TCH/H to target TCH/F

Description

Page 420: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

404 Confidential and Proprietary Information of ZTE CORPORATION

Refer to the description of Counter C109105 in Section Handover Counters Explanation.

Calculation formula

C11947 = C109105

C11948 Definition

Number of successful handovers (intra-cell) between serving TCH/H to target TCH/F

Description

Refer to the description of Counter C109106 in Section Handover Counters Explanation.

Calculation formula

C11948 = C109106

C11949 Definition

Number of handover (intra-cell) execution between TCH/Hs

Description

Refer to the description of Counter C109107 in Section Handover Counters Explanation.

Calculation formula

C11949 = C109107

C11950 Definition

Number of successful handovers (intra-cell) between TCH/Hs

Description

Refer to the description of Counter C109108 in Section Handover Counters Explanation.

Calculation formula

C11950 = C109108

C11951 Definition

Number of handover (inter-cell) attempts from TCH/F to any channel in the target cell.

Page 421: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 405

Description

Refer to the description of Counter C109109 in Section Handover Counters Explanation.

Calculation formula

C11951 = C109109

C11952 Definition

Number of handover (inter-cell) execution between TCH/Hs

Description

Refer to the description of Counter C109110 in Section Handover Counters Explanation.

Calculation formula

C11952 = C109110

C11953 Definition

Number of successful handover (inter-cell) between TCH/Fs

Description

Refer to the description of Counter C109111 in Section Handover Counters Explanation.

Calculation formula

C11953 = C109111

C11954 Definition

Number of handover execution (inter-cell) from serving TCH/F to target TCH/H

Description

Refer to the description of Counter C109112 in Section Handover Counters Explanation.

Calculation formula

C11954 = C109112

C11955 Definition

Page 422: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

406 Confidential and Proprietary Information of ZTE CORPORATION

Number of successful handover (inter-cell) from serving TCH/F to target TCH/H

Description

Refer to the description of Counter C109113 in Section Handover Counters Explanation.

Calculation formula

C11955 = C109113

C11956 Definition

Number of handover (inter-cell) attempts from TCH/H to any channel in the target cell.

Description

Refer to the description of Counter C109114 in Section Handover Counters Explanation.

Calculation formula

C11956 = C109114

C11957 Definition

Number of handover execution (inter-cell) from serving TCH/H to target TCH/F

Description

Refer to the description of Counter C109115 in Section Handover Counters Explanation.

Calculation formula

C11957 = C109115

C11958 Definition

Number of successful handover (inter-cell) from serving TCH/H to target TCH/F

Description

Refer to the description of Counter C109116 in Section Handover Counters Explanation.

Calculation formula

C11958 = C109116

Page 423: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 407

C11959 Definition

Number of handover (inter-cell) execution between TCH/Hs

Description

Refer to the description of Counter C109117 in Section Handover Counters Explanation.

Calculation formula

C11959 = C109117

C11960 Definition

Number of successful handover (inter-cell) between TCH/Hs

Description

Refer to the description of Counter C109118 in Section Handover Counters Explanation.

Calculation formula

C11960 = C109118

C11961 Definition

Number of DTAP messages used for point-to-point short messages on uplink FACCH/H

Description

Refer to the description of Counter C10220 in Section SAPI 3 Counters Explanation.

Calculation formula

C11961 = C10220

C11962 Definition

Number of DTAP messages used for point-to-point short messages on downlink FACCH/H

Description

Refer to the description of Counter C10221 in Section SAPI 3 Counters Explanation.

Calculation formula

Page 424: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

408 Confidential and Proprietary Information of ZTE CORPORATION

C11962 = C10221

C11963 Definition

Number of DTAP messages used for point-to-point short messages on uplink SACCH/F

Description

Refer to the description of Counter C10222 in Section SAPI 3 Counters Explanation.

Calculation formula

C11963 = C10222

C11964 Definition

Number of DTAP messages used for point-to-point short messages on downlink SACCH/F

Description

Refer to the description of Counter C10223 in Section SAPI 3 Counters Explanation.

Calculation formula

C11964 = C10223

C11965 Definition

Number of DTAP messages used for point-to-point short messages on uplink SACCH/H

Description

Refer to the description of Counter C10224 in Section SAPI 3 Counters Explanation.

Calculation formula

C11965 = C10224

C11966 Definition

Number of DTAP messages used for point-to-point short messages on downlink SACCH/H

Description

Page 425: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 409

Refer to the description of Counter C10225 in Section SAPI 3 Counters Explanation.

Calculation formula

C11966 = C10225

C11967 Definition

Number of successful handovers from TCH full rate to TCH half rate

Description

The system triggers TCH/F-TCH/H conversion process according to the set threshold. And TCH/F and TCH/H quantity counted in real time. FIGURE 36 illustrates the conversion process.

FIGURE 36 - CONVERSIONS F R O M T C H / F T O T C H / H

BTS Agt Pn ExchangeProc P0 ExchangeProc

EV_ DYN _ CHANGE _ REQ

EV _BTS_ DATA

EV_BTS_ DATA _ ACK

EV_P0_ DATA

Modify Pn database

Modify Po database

EV _P0_ ACK

Measurement point

Counter ‘C11967’ increments when RMM receives the EV_P0_ACK message during the TCHF_TO_TCHH conversion process.

C11968 Definition

Number of successful handover from TCH half rate to TCH full rate.

Description

Handover process in this case is opposite to the one described in Counter C11967.

Page 426: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

410 Confidential and Proprietary Information of ZTE CORPORATION

Measurement point

Counting when RMM receives the EV_P0_ACK message during TCHH_TO_TCHF conversion process.

C11969 Definition

Number of handover from TCH full rate to TCH half rate fails.

Description

Handover fails if Conversion from TCHF to TCHH is unsuccessful.

Measurement point

Counter ‘C11969’ increments if RMM does not receive the EV_BTS_DATA_ACK or EV_P0_ACK message within specified time.

C11970 Definition

Number of handover from TCH half rate to TCH full rate fails.

Description

Handover fails if Conversion from TCHH to TCHF is unsuccessful.

Measurement point

Counter ‘C11970’ increments if RMM does not receive the EV_BTS_DATA_ACK or EV_P0_ACK message within specified time.

C11971 Definition

Mean number of HR channels

Description

Counter ‘C11971’ represents the Mean number of TCH/Hs in the cell. Mean number of TCH/Hs includes all the available and unavailable TCH/Hs.

Measurement point

Querying the database during periodic measurements

C11972 Definition

Maximum number of HR channels

Description

Page 427: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 28 - Half Rate Statistics

Confidential and Proprietary Information of ZTE CORPORATION 411

Omitted

C11973 Definition

Minimum number of HR channels

Description

Omitted

Page 428: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

412 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 429: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 413

C h a p t e r 29

Reserved Channel Measurement

This chapter covers the following topics:

Reserved Channel Counters

Reserved Channel Counters These counters provide statistics of reserved channels Allocation in case of assignment, internal handover, and external handover-in.

TAB L E 44 C O U N T E R S F O R R E S E R V E D C H AN N E L S

Counter No. Definition

C10470 Number of allocations of reserved full rate channel in assignment (voice)

C10471 Number of allocations of reserved full rate channel in assignment (data)

C10472 Number of allocations of reserved full rate channel in handover (voice)

C10473 Number of allocations of reserved full rate channel in handover (data)

Reserved Channel Counters Explanation C10470 Definition

Number of allocations of reserved full rate channel in assignment (voice)

Page 430: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

414 Confidential and Proprietary Information of ZTE CORPORATION

Description

C10470 represents number of reserved full rate voice channel activations for assignment. It also includes successful channel activations after queuing.

Measurement Point

C10470 increments after each single successful reserved channel activation. (B1 in FIGURE 33)

C10471 Definition

Number of allocations of reserved full rate channel in assignment (data)

Description

C10471 represents number of reserved full rate data channel activations for assignment. It also includes successful channel activations after queuing.

Measurement Point

C10471 increments after each single successful reserved channel activation. (B1 in FIGURE 33)

C10472 Definition

Number of allocating the reserved full rate channel in handover (voice)

Description

C10472 represents number of reserved full rate voice channel activations for handover. It also includes successful channel activations after queuing or force release.

Measurement Point

C10472 increments after each single successful reserved channel activation. (C1 in FIGURE 34 D1 in FIGURE 35)

C10473 Definition

Number of allocating the reserved full rate channel in handover (data)

Description

C10473 represents number of reserved full rate data channel activations for handover. It also includes successful channel activations after queuing or force release.

Page 431: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 29 - Reserved Channel Measurement

Confidential and Proprietary Information of ZTE CORPORATION 415

Measurement Point

C10473 increments after each single successful reserved channel activation. (C1 in FIGURE 34 & D1 in FIGURE 35 )

Page 432: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

416 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 433: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 417

C h a p t e r 30

Packet Switched Service Measurement

This Chapter covers the following topics:

PS Basic Measurement Counters

NS Sub Layer Counters

BSSGP Layer Counters

NSE Performance Statistic Counters

PS Traffic Counters

Resource Management Counters

PS Basic Measurement Counters The PS basic measurement counters are of two types:

Cell Counters

BSC Counters

Cell Counters: PS Basic Measurement Counters that relates to cell.

BSC Counters: PS Basic Measurement Counters that relates to BSC.

Table 45 lists all the PS basic measurement counters that take cell as measurement unit.

TAB L E 45 PS B AS I C M E AS U R E M E N T C O U N T E R S – C E L L AS T H E U N I T

Counter Number. Definition

C70001 Number of “Packet paging” that BSC initiates

C70002 Number of “Circuit paging” that BSC initiates

C70003 Number of used PPCH

Page 434: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

418 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Definition

C70004 Total number of PRACH

C70005 Number of used PAGCH

C70006 Number of conversion from CS1 to CS2

C70007 Number of conversion from CS2 to CS1

C70008 Uplink power control

C70009 Number of forced retracting dynamic PDCH by BSC

C70010 Number of successfully activating dynamic PDCH

C70011 Number of failed activating dynamic PDCH

C70012 Number of PDCH failure

C70013 Number of PDCH failure recovery

C70014 Number of packet messages waiting to be send on PCH-AGCH

C70015 Number of assignment messages waiting to be send on PPCH-PAGCH

C70016 Number of paging messages deleted from PCH queue

C70017 Number of packet paging messages deleted from PPCH queue

C70018 Number of failed transmitted paging messages from the cell

C70019 Average number of available PDCH

C70020 Average number of occupied PDCH

C70021 Maximum number of occupied PDCH

C70022 Minimum number of occupied PDCH

C70023 Average number of messages in PCH-AGCH queue

C70024 Average number of messages in PPCH-PAGCH queue

C70025 Number of failed attempts of requesting packet channel due to number available channels

C70026 Number of “DOWNLOAD-BSS-PFC” message that BSS sends

C70027 Number of “CREATE-BSS-PFC” message that BSS receives

C70028 Number of “CREATE-BSS-PFC-ACK” message that BSS sends

C70029 Number of “CREATE-BSS-PFC-NACK” message that BSS sends

C70030 Number of “MODIFY-BSS-PFC” message that BSS sends

C70031 Number of “MODIFY-BSS-PFC-ACK” message that BSS receives

C70032 Number of “DELETE-BSS-PFC” message that BSS receives

C70033 Number of “DELETE-BSS-PFC-ACK” message that BSS sends

C70034 Number of attempt of increasing timeslot of dynamic Abis-interface

C70035 Number of successful increasing timeslot of dynamic Abis-interface

C70036 Number of attempt of decreasing timeslot of dynamic Abis-interface

C70037 Number of successful decreasing timeslot of dynamic Abis-interface

C70038 Total number of adjusting uplink packet channel frame Number

Page 435: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 419

Counter Number. Definition

C70039 Total number of adjusting downlink packet channel frame Number.

C70040 Total number of requesting uplink packet channel

C70041 Total number of requesting downlink packet channel

C70042 Total number of uplink signaling TBF link establishment

C70043 Total number of downlink signaling TBF link establishment

C70044 Total number of data blocks received by packet uplink channel

C70045 Total number of signaling blocks received by packet uplink channel

C70046 Total number of signaling blocks that packet downlink channel sends

C70047 Total number of data blocks that packet downlink channel sends

C70048 Total number of data blocks sending according to given Abis bandwidth

C70049 Total bytes of effective upper layer protocol data sent by packet downlink channel

C70050 Total bytes of effective upper layer protocol data received by packet uplink channel

C70051 Number of uplink GPRS TBF existing simultaneously in the cell

C70052 Number of downlink GPRS TBF existing simultaneously in the cell

C70053 Number of uplink EGPRS TBF existing simultaneously in the cell

C70054 Number of downlink EGPRS TBF existing simultaneously in the cell

C70055 Total number of GPRS uplink data TBF link establishment

C70056 Total number of establishing GPRS uplink data TBF on PACCH

C70057 Total number of GPRS downlink data TBF link establishment

C70058 Total number of establishing GPRS downlink data TBF on PACCH

C70059 Total data quantity carried by GPRS uplink data TBF

C70060 Total number of completion of GPRS uplink data TBF

C70061 Total duration of GPRS uplink data TBF

C70062 Total data quantity carried by GPRS downlink data TBF

C70063 Total number of completion of GPRS downlink data TBF

C70064 Total duration of GPRS downlink data TBF

C70065 Total number of effective data blocks received by GPRS uplink TBF

C70066 Total number of GPRS uplink TBF NACK blocks

C70067 Total number of effective data blocks that GPRS downlink TBF sends

C70068 Total number of GPRS downlink TBF NACK blocks

C70069 Total number of EGPRS uplink data TBF link establishment

C70070 Total number of establishing EGPRS uplink data TBF on PACCH

C70071 Total number of EGPRS downlink data TBF link establishment

C70072 Total number of establishing EGPRS downlink data TBF on PACCH

C70073 Total data quantity carried by EGPRS uplink data TBF

Page 436: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

420 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Definition

C70074 Total number of completion of EGPRS uplink data TBF

C70075 Total duration of EGPRS uplink data TBF

C70076 Total Number of data carried by EGPRS downlink data TBF

C70077 Total number of completion of EGPRS downlink data TBF

C70078 Total duration of EGPRS downlink data TBF

C70079 Total number of effective data blocks received by EGPRS uplink TBF

C70080 Total number of EGPRS uplink TBF NACK blocks

C70081 Total number of data blocks sent by EGPRS downlink TBF (except for Pending ACK block)

C70082 Total number of EGPRS downlink TBF NACK blocks

C70083 Total number of downlink signaling LLC frame packets

C70084 Total number of discarded downlink signaling LLC frame packets

C70085 Total number of downlink GPRS data frame packets

C70086 Total number of discarded downlink GPRS data frame packets

C70087 Total number of downlink EGPRS data frame packets

C70088 Total number of discarded downlink EGPRS data frame packets

C70089 Number of stale GPRS uplink TBF window

C70090 Number of stale EGPRS uplink TBF window

C70091 Number of stale GPRS downlink TBF window

C70092 Number of stale EGPRS downlink TBF window

C70093 Total number of abnormal release of uplink signaling TBF

C70094 Total number of abnormal release of uplink GPRS data TBF

C70095 Total number of abnormal release of uplink EGPRS data TBF

C70096 Total number of abnormal release of downlink signaling TBF

C70097 Total number of abnormal release of downlink GPRS data TBF

C70098 Total number of abnormal release of downlink EGPRS data TBF

C70099 Number of requests for increasing Abis bandwidth by uplink TBF

C70100 Number of requests for increasing Abis bandwidth by downlink TBF

C70101 Number of handover from GMSK to 8PSK

C70102 Number of handover from 8PSK to GMSK

C70103 Number of handover from CS1, 2 to CS3, 4

C70104 Number of handover from CS3, 4 to CS1, 2

C70105 Total number of data packets send to peripheral modules by BRP

C70106 Total number of data packets that BRP receives from peripheral modules

C70107 Total number of data packets send to BRP by peripheral modules

C70108 Total number of data packets received by peripheral modules that are sent by BRP

Page 437: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 421

Counter Number. Definition

C70109 Number of outgoing handover from cell

C70110 Number of handover-in cell

C70111 Total number of CS1 data blocks received by packet uplink channel

C70112 Total number of CS2 data blocks received by packet uplink channel

C70113 Total number of CS3 data blocks received by packet uplink channel

C70114 Total number of CS4 data blocks received by packet uplink channel

C70115 Total number of CS1 data blocks received by packet downlink channel

C70116 Total number of CS2 data blocks received by packet downlink channel

C70117 Total number of CS3 data blocks received by packet downlink channel

C70118 Total number of CS4 data blocks received by packet downlink channel

C70119 Minimum number of available PDCH

C70120 Total number of uplink blocks received by uplink channel (including DUMMY block)

C70121 Total number of downlink blocks sent by downlink channel (including DUMMY block)

Table 46 lists all the PS Basic Measurement Counters that take BSC as measurement unit.

TAB L E 46 C O U N T E R S F O R PS B AS I C M E AS U R E M E N T – BSC AS U N I T

Counter Number. Definition

C90001 Total number of uplink data packets carried by BRCH

C90002 Total number of downlink data packets carried by BRCH

C90003 Number of interruption due to BRCH receiving failure

C90004 Total number of data packets send to FRP by BRP

C90005 Total number of data packets received by BRP that are sent by FRP

C90006 Total number of data packets send to BRP by FRP

C90007 Total number of data packets received by FRP that are sent by BRP

PS Basic Measurement Counters Explanation C70001 Definition

Number of “Packet paging” that BSC initiates

Description

Page 438: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

422 Confidential and Proprietary Information of ZTE CORPORATION

C70001 represents number of “Packet paging” that BSC initiates. The paging message comes through Gb interface.

Measurement Point

C70001 increments when BSC receives packet paging message on PTP.

C70002 Definition

Number of “Circuit paging” that BSC initiates

Description

C70003 represents number of “Circuit paging” that BSC initiates. Paging message comes through Gb interface.

Measurement Point

C70003 accumulates one every time BSC receives on PTP circuit paging message.

C70003 Definition

Number of used PPCH

Description

C70003 represents number of PPCH in cell, currently in use during statistic period.

Measurement Point

C70004 increments when BSC uses PPCH to send paging message or implements downlink assignment.

C70004 Definition

Number of used PRACH

Description

C70004 represents number of PRACH in cell, currently in use during statistic period.

Measurement Point

C70004 increments when BSC receives uplink request send on PRACH.

C70005 Definition

Number of used PAGCH

Page 439: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 423

Description

C70005 represents number of PAGCH in cell, currently in use during statistic period.

Measurement Point

C70005 increments when BSC uses PAGCH to send uplink assignment message.

C70006 Definition

Number of conversions from CS1 to CS2

Description

C70006 represents number of TBF coding scheme’s conversion from CS1 to CS2.

Measurement Point

C70006 increments when BSC initiates a conversion from CS1 to CS2 according to current channel status and wireless environment.

C70007 Definition

Number of conversion from CS2 to CS1

Description

C70007 represents number of TBF coding scheme’s conversion from CS2 to CS1.

Measurement Point

C70007 increments when BSC initiates a conversion from CS2 to CS1 according to current channel status and wireless environment.

C70008 Definition

Uplink power control

Description

C70008 represents number of uplink power control of mobile phone implementations during uplink TBF process in cell by BSC.

Measurement Point

C70008 increments every time BSC initiates an uplink power control according to the current channel status.

Page 440: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

424 Confidential and Proprietary Information of ZTE CORPORATION

C70009 Definition

Number of forced retractions of dynamic PDCH by BSC

Description

C70009 represents number of dynamic channel conversions from PDTCH to TCH by BSC.

Measurement Point

C70010 increments when BSC converts dynamic channel from PDTCH to TCH successfully.

C70010 Definition

Number of successful activations of dynamic PDCH

Description

C70010 represents number of successful conversions from TCH to dynamic PDTCH

Measurement Point

C70010 increments when BSC converts dynamic channel from TCH to PDTCH successfully.

C70011 Definition

Number of failed dynamic PDCH activations

Description

C70011 represents number of failed conversions from dynamic TCH to PDTCH

Measurement Point

C70011 increments when dynamic channel conversion from TCH to PDTCH becomes unsuccessfully.

C70012 Definition

Number of PDCH failures

Description

C70012 represents number of PDCH failures when PDTCH is blocked.

Measurement Point

Page 441: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 425

BSC represents PDCH blocking times and directly writes it to buffer. C70012 increments every time when PDCH is blocked.

C70013 Definition

Number of PDCH failure recoveries

Description

C70013 represents number of unblocking PDTCH.

Measurement Point

BSC represents PDCH number of unblocks and directly writes it to buffer. C70014 increments every time when PDCH is unblocked.

C70014 Definition

Numbers of packet messages waiting to be send on PCH-AGCH

Description

C70014 represents number of packet messages waiting to be send on PCH-AGCH

Measurement Point

C70014 increments every time when BSC sends assignment message to BTS on CCCH.

C70015 Definition

Numbers of assignment messages waiting to be send on PPCH-PAGCH

Description

C70015 represents number of packet messages waiting to be send on PCH-PAGCH.

Measurement Point

C70015 increments every time when MP Service module sends assignment message on PCCCH to BRP.

C70016 Definition

Number of paging messages deleted from PCH queue

Description

Page 442: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

426 Confidential and Proprietary Information of ZTE CORPORATION

C70016 represents average number of paging messages deleted from PCH queue.

Measurement Point

C70016 increments every time when BTS deletes paging message on PCH.

C70017 Definition

Number of packet paging messages deleted from PPCH queue

Description

C70017 represents average number of paging messages deleted from PPCH queue.

Measurement Point

C70017 increments every time when BTS deletes paging message on PPCH.

C70018 Definition

Number of transmitted paging message failures from cell

Description

C70018 represents number of transmitted paging message failures from cell.

Measurement Point

C70018 increments every time when BTS fails to transmit paging message.

C70010 Definition

Average number of available PDCH

Description

C70010 represents average number of available PDCH in cell.

Measurement Point

BSC records samples and directly writes to buffer. Sampling uses sum/sample rate within five minutes.

C70020 Definition

Page 443: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 427

Average number of occupied PDCH

Description

C70020 represents average number of occupied PDCH in cell.

Measurement Point

BSC records and directly writes to buffer.

C70021 Definition

Maximum number of occupied PDCH

Description

C70021 represents maximum number of occupied PDCH.

Measurement Point

Service module on Mp records and directly writes to buffer.

C70022 Definition

Minimum number of occupied PDCH

Description

C70022 represents minimum number of occupied PDCH

Measurement Point

Service module on Mp records and directly writes to buffer.

C70023 Definition

Average number of messages in PCH-AGCH queue

Description

C70023 represents average number of messages waiting in a queue, will be send on PCH-AGCH.

Measurement Point

BTS service module obtains length of the message that queued on PCH-AGCH at sampling point.

C70024 Definition

Average number of assignment messages in PPCH-PAGCH queue

Page 444: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

428 Confidential and Proprietary Information of ZTE CORPORATION

Description

C70024 represents number of messages waiting in a queue, will be send on PCH-PAGCH

Measurement Point

BTS service module obtains length of the message that queued on PPCH-PAGCH at sampling point.

C70025 Description

Number of failed attempts of requesting packet channel due to unavailability of channels

Definition

C70025 represents average number of packet messages waiting to be send on PCH-PAGCH

Measurement Point

C70025 increments every time when BSC fails to count requests of packet channel due to unavailability of channels.

C70026 Definition

Number of DOWNLOAD-BSS-PFC message that BSS sends

Description

C70026 represents number of DOWNLOAD-BSS-PFC message that BSS sends

Measurement Point

C70026 increments every time Mp service module sends DOWNLOAD-BSS-PFC message.

C70027 Definition

Number of CREATE-BSS-PFC message that BSS receives

Description

C7007 represents number of CREATE-BSS-PFC message that BSS receives

Measurement Point

C70027 increments every time when Mp service module receives CREATE-BSS-PFC message.

Page 445: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 429

C70028 Definition

Number of CREATE-BSS-PFC-ACK message that BSS sends

Description

C70029 represents number of CREATE-BSS-PFC-ACK message that BSS sends

Measurement Point

C70029 increments every time when BSC sends CREATE-BSS-PFC-ACK message.

C70029 Definition

Number of CREATE-BSS-PFC-NACK messages that BSS sends

Description

C70029 represents number of CREATE-BSS-PFC-NACK message send in cell

Measurement Point

C70029 increments every time when BSC sends CREATE-BSS-PFC-NACK message.

C70030 Definition

Number of MODIFY-BSS-PFC message that BSS sends

Description

C70030 represents number of MODIFY-BSS-PFC message send in cell

Measurement Point

C70030 increments every time when BSC sends MODIFY-BSS-PFC message.

C70031 Definition

Number of MODIFY-BSS-PFC-ACK message that BSS receives

Description

C70031 represents number of MODIFY-BSS-PFC-ACK message received in cell

Page 446: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

430 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C70031 increments every time when BSC sends MODIFY-BSS-PFC-ACK message.

C70032 Definition

Number of DELETE-BSS-PFC message that BSS receives

Description

C70033 represents number of “DELETE-BSS-PFC” message received in cell.

Measurement Point

C70033 increments every time when BSC sends DELETE-BSS-PFC message.

C70033 Definition

Number of DELETE-BSS-PFC-ACK message that BSS sends

Description

C70033 represents number of DELETE-BSS-PFC-ACK message that BSS sends in cell.

Measurement Point

C70033 increments every time when BSC sends DELETE-BSS-PFC-ACK message.

C70034 Definition

Number of attempts to increase timeslot of dynamic Abis-interface

Description

C70034 represents number of attempts to expand Abis communication link.

Measurement Point

C70035 increments every time when BRP service module on PCU initiates a dynamic Abis-interface expansion.

C70035 Definition

Number of successful increase in timeslot of dynamic Abis-interface

Page 447: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 431

Description

C70035 represents number of successful expansion of Abis communication link.

Measurement Point

C70035 increments every time when BRP service module on PCU successfully initiates a dynamic Abis-interface expansion.

C70036 Definition

Number of attempts to decrease timeslot of dynamic Abis-interface

Description

C70036 represents number of attempts to decrease Abis communication link.

Measurement Point

C70036 increments every time when BRP service module on PCU initiates a dynamic Abis-interface reduction.

C70037 Definition

Number of successful decrements in timeslots of dynamic Abis-interface

Description

C70037 represents number of attempts to decrease Abis communication link

Measurement Point

C70037 increments every time when BRP service module on PCU successfully initiates a dynamic Abis-interface reduction.

C70038 Definition

Total number of adjustments of frame number of uplink packet channel

Description

C70038 represents number of adjustments of frame number of uplink packet channel in cell

Measurement Point

C70038 increments every time when BRP service module on PCU adjusts frame number of uplink packet channel.

Page 448: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

432 Confidential and Proprietary Information of ZTE CORPORATION

C70039 Definition

Total number of adjustment for frame number of downlink packet channel

Description

C70040 represents total number of times adjustments for frame number of downlink packet channel in the cell

Measurement Point

C70039 increments every time when BRP service module on PCU adjusts frame number of downlink packet channel.

C70040 Definition

Total number of requests for uplink packet channel

Description

C70040 represents total number of requests for uplink packet channel

Measurement Point

C70040 increments every time when MP Service module receives packet channel request that include BCCH, PBCCH, and PACCH.

C70041 Definition

Total number of requests for downlink packet channel

Description

C70041 represents total number of requests for downlink packet channel

Measurement Point

C70041 increments every time when MP Service module receives request for downlink packet channel sent by BRP service module on PCU.

C70042 Definition

Total number of uplink signaling TBF link establishments

Description

C70042 represents total number of uplink signaling TBF link establishments

Page 449: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 433

Measurement Point

C70042 represents every time when MP Service module receives uplink ONE PHASE access request or TWO PHASE access request. This time signaling transmission is required in resource request message.

C70043 Definition

Total number of downlink signaling TBF link establishments

Description

C70043 represents total number of uplink signaling TBF link establishments.

Measurement Point

C70043 increments when MP Service module receives downlink signaling TBF access request sent by BRP.

BSC judges T bit in downlink LLC frame. If T bit equals to zero, then downlink signaling TBF access request initiates. If T bit equals to one, then downlink data TBF link establishment request initiates.

C70044 Definition

Total number of data blocks received by packet uplink channel

Description

C7004 represents number of data blocks received by packet uplink channel.

Measurement Point

C7004 increments when BSC receives effective uplink data block.

The effective data block refers to uplink data block that is located to TBF instance.

C70045 Definition

Total number of signaling blocks received by packet uplink channel

Description

C70045 represents total number of signaling blocks received by packet uplink channel.

Measurement Point

C70045 increments when BSC receives effective uplink signaling block.

Page 450: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

434 Confidential and Proprietary Information of ZTE CORPORATION

The effective signaling block refers to uplink signaling block that is located to uplink signaling block.

C70046 Definition

Total number of signaling blocks that packet downlink channel sends

Description

C70046 represents number of signaling blocks sent by packet downlink channel.

Measurement Point

C70046 increments when BSC successfully sends downlink signaling block.

Sending downlink-signaling block successfully refers to downlink signaling block that system writes in channel data buffer successfully. Downlink signaling block does not include PACKET DUMMY CONTROL message.

C70047 Definition

Total number of data blocks that packet downlink channel sends

Description

C70047 represents total number of data blocks sent by packet downlink channel.

Measurement Point

C70047 increments when BRP service module successfully sends downlink data block.

Sending downlink data block successfully refers to downlink data block, which system writes in channel data buffer successfully.

C70048 Definition

Number of data blocks sending according to given Abis bandwidth

Description

C70048 represents number of data blocks that will be send according to given Abis bandwidth.

Measurement Point

C70048 increments when BRP service module successfully sends data block which accords with maximum bearer capability of Abis bandwidth.

Page 451: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 435

This counter helps to check the relationship between data block coding scheme and bandwidth, as shown in Table 47.

TAB L E 47 C O R R E S P O N D E N C E R E L AT I O N S H I P S B E T W E E N B AN D W I D T H AN D C O D I N G S C H E M E

Abis bandwidth (Timeslot) Coding type

1 CS1, CS2, MCS1 and MCS2

2 CS3, CS4, MCS3, MCS4 and MCS5

3 MCS6

4 MCS7

5 MCS8 and MCS9

C70049 Definition

Total bytes of effective upper layer protocol data sent by packet downlink channel

Description

C70049 represents number of signaling blocks sent by packet downlink channel in cell.

Measurement Point

Number of bytes of LLC frame carried by the data block is added when BSC successfully sends downlink data block.

Successful sending of downlink data block refers to downlink data block that system writes to channel data buffer successfully.

C70050 Definition

Total bytes of effective upper layer protocol data received by packet uplink channel

Description

C70050 represents total bytes of effective upper layer protocol data received by packet uplink channel.

Measurement Point

C70050 increments when BSC successfully receives uplink data block.

C70051 Definition

Number of uplink GPRS TBF existing simultaneously in cell

Page 452: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

436 Confidential and Proprietary Information of ZTE CORPORATION

Description

C70051 represents Number of uplink GPRS TBF existing simultaneously in cell.

Measurement Point

C70051 increments when BSC successfully establishes an uplink GPRS TBF. Similarly, C70051 increments when BSC successfully releases an uplink GPRS TBF.

C70052 Definition

Number of downlink GPRS TBF existing simultaneously in the cell

Description

C70052 represents Number of downlink GPRS TBF existing simultaneously in cell

Measurement Point

C70052 increments when BSC successfully establishes downlink GPRS TBF. Similarly, C70052 decrements when BSC successfully releases downlink GPRS TBF.

C70053 Definition

Number of uplink EGPRS TBF existing simultaneously in cell

Description

C70053 represents Number of uplink EGPRS TBF existing simultaneously in the cell.

Measurement Point

C70053 increments when BSC successfully establishes an uplink EGPRS TBF. Similarly, C70053 decrements when BSC successfully releases an uplink EGPRS TBF.

C70054 Definition

Number of downlink EGPRS TBF existing simultaneously in cell

Description

C70055 represents Number of downlink EGPRS TBF existing simultaneously in cell.

Page 453: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 437

Measurement Point

C70055 increments when BSC successfully establishes a downlink EGPRS TBF. Similarly, C70055 decrements when BSC successfully releases downlink EGPRS TBF.

C70055 Definition

Total number of establishments of GPRS uplink data TBF link

Description

C70055 represents total number of establishments of GPRS uplink data TBF.

Measurement Point

C70055 increments when BSC successfully establishes an uplink GPRS data TBF.

C70056 Definition

Total number of establishing GPRS uplink data TBF on PACCH

Description

C70056 represents number of establishing GPRS uplink data TBF on PACCH.

Measurement Point

C70057 increments when BSC successfully establishes an uplink GPRS data TBF.

C70057 Definition

Total number of GPRS downlink data TBF link establishments

Description

C70057 represents total number of GPRS downlink data TBF link establishment.

Measurement Point

C70057 increments when BSC successfully establishes a downlink GPRS data TBF.

C70058 Definition

Page 454: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

438 Confidential and Proprietary Information of ZTE CORPORATION

Total number of establishing GPRS downlink data TBF on PACCH

Description

C70058 represents total time of GPRS downlink data TBF link establishment on PACCH.

Measurement Point

C70058 increments when BSC successfully establishes a downlink GPRS data TBF.

C70059 Definition

Total number of bytes of LLC frame carried by GPRS uplink data TBF

Description

C70059 represents total number of bytes of LLC frame carried by GPRS uplink data TBF.

Measurement Point

After uplink TBF normal release, BSC adds total number of bytes of LLC frame that TBF transmits to the counter.

C70060 Definition

Total number of completion of GPRS uplink data TBF

Definition

C70060 represents total time of completion of GPRS uplink data TBF.

Measurement Point

C70060 increments when BSC normally releases an uplink data TBF.

C70061 Definition

Total duration of GPRS uplink data TBF

Description

C70061 represents total time of completion of GPRS uplink data TBF.

Measurement Point

C70062 records starting frame number when BSC successfully establishes an uplink data TBF. Similarly, C70062 records ending frame number when BSC normally releases an uplink data TBF. The difference between starting frame number and ending frame number is

Page 455: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 439

duration of TBF. This counter records the duration. Unit of duration is block that is 20 ms.

C70062 Definition

Total number of bytes of LLC frame carried by GPRS downlink data TBF

Description

C70062 represents total number of bytes of LLC frame carried by GPRS downlink data TBF.

Measurement Point

BRP performance measurement module adds counter variable of total bytes number of LLC frame carried by GPRS downlink data TBF that takes cell as unit. Shared memory of service module and performance measurement module saves the variable. BSC adds the total bytes number of LLC frame transmitted by TBF to the counter when a downlink TBF releases normally.

C70063 Definition

Total time of completion of GPRS downlink data TBF

Description

C70063 represents total time of completion of GPRS uplink data TBF.

Measurement Point

C70063 increments when BSC normally releases a downlink data TBF.

C70064 Definition

Total duration of GPRS downlink data TBF

Description

C70064 represents total duration of GPRS downlink data TBF.

Measurement Point

C70064 records starting frame number when BSC successfully establishes downlink data TBF. C70064 records the ending frame number when BSC normally releases a downlink data TBF. The difference between the starting frame number and ending frame number is the duration of TBF. C70064 represents time, which is one block time duration of 20ms.

Page 456: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

440 Confidential and Proprietary Information of ZTE CORPORATION

C70065 Definition

Total number of effective data blocks received by GPRS uplink TBF

Description

The counter represents number of effective data blocks received by GPRS uplink TBF.

Measurement Point

The counter increments to one every time BSC receives an effective data block.

C70066 Definition

Total number of NACK blocks received by GPRS uplink TBF

Description

C70066 represents number of NACK blocks received by GPRS uplink TBF.

Measurement Point

When an uplink TBF normally ends, BSC adds the number of NACK blocks received by the TBF to the counter.

C70067 Definition

Total number of effective data blocks that GPRS downlink TBF sends

Description

C70067 represents number of effective data blocks sent by GPRS downlink TBF.

Measurement Point

When a downlink TBF normally ends, BSC adds number of effective data blocks sent by TBF to the counter.

Effective number of data blocks refers to NACK blocks that is send first time and retransmitted.

C70068 Definition

Total number of GPRS downlink TBF NACK blocks

Description

C70069 represents number of NACK blocks sent by GPRS uplink TBF

Page 457: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 441

Measurement Point

When a downlink TBF normally ends, BSC adds number of NACK blocks sent by TBF to the counter.

C70069 Definition

Total time of establishment of EGPRS uplink data TBF link

Definition

C70069 represents number of establishment of EGPRS uplink data TBF link.

Measurement Point

C70069 increments when BSC successfully establishes a GPRS uplink EGPRS data TBF.

C70070 Definition

Total time of establishing EGPRS uplink data TBF on PACCH

Description

C70070 represents total time of establishing EGPRS uplink data TBF on PACCH.

Measurement Point

C70070 increments when BSC successfully establishes an uplink EGPRS data TBF on PACCH.

C70071 Definition

Total time of EGPRS downlink data TBF link establishment

Description

C70071 represents total time of EGPRS downlink data TBF link establishment.

Measurement Point

C70071 increments when BSC successfully establishes a downlink EGPRS data TBF.

C70072 Definition

Total time of establishing EGPRS downlink data TBF on PACCH

Page 458: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

442 Confidential and Proprietary Information of ZTE CORPORATION

Description

C70072 represents total time of establishing EGPRS downlink data TBF on PACCH.

Measurement Point

C70072 increments when BSC successfully establishes a downlink EGPRS data TBF on PACCH.

C70073 Definition

Total bytes number of LLC frame carried by EGPRS uplink data TBF

Description

C70073 represents total bytes number of LLC frame carried by EGPRS uplink data TBF.

Measurement Point

When an EGPRS uplink data TBF releases normally, BSC adds total bytes number of LLC frame carried by TBF to the counter.

C70074 Definition

Total time of completion of EGPRS uplink data TBF

Description

C70074 represents total time of completion of EGPRS uplink data TBF.

Measurement Point

C70074 increments when BSC normally releases an EGPRS uplink data TBF.

C70075 Definition

Total duration of EGPRS uplink data TBF

Description

C70075 represents time of completion of EGPRS uplink data TBF.

Measurement Point

C70075 records starting frame number when RP service module successfully establishes a downlink data TBF. Similarly, C70075 records ending frame number when BSC normally releases an EGPRS uplink data TBF. The difference between starting frame number and

Page 459: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 443

ending frame number is the duration of TBF. The duration adds to the counter. Unit of duration is block that is 20 ms.

C70076 Definition

Total number of bytes of LLC frame carried by EGPRS downlink data TBF

Description

C70076 represents total number of bytes of LLC frame carried by EGPRS downlink data TBF.

Measurement Point

When an EGPRS downlink data releases normally, BSC adds the total number of bytes of LLC frame transmitted by the TBF to the counter.

C70077 Definition

Total number of completion of EGPRS downlink data TBF

Description

C70077 represents total number of bytes of LLC frame carried by EGPRS downlink data TBF.

Measurement Point

Definition

C70077 increments when BSC normally releases an EGPRS downlink data.

C70078 Definition

Total duration of EGPRS downlink data TBF

Description

C70078 represents total duration of EGPRS downlink data TBF.

Measurement Point

C70078 records starting frame number when BSC successfully establishes a downlink data TBF. C70078 records ending frame number when BSC normally releases an EGPRS downlink data TBF. The difference between starting frame number and ending frame number is the duration of TBF. The duration adds to the counter. Unit of duration is TDMA frame.

Page 460: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

444 Confidential and Proprietary Information of ZTE CORPORATION

C70079 Definition

Total number of effective data blocks received by EGPRS uplink TBF

Description

C70079 represents total number of effective data blocks received by EGPRS uplink TBF.

Measurement Point

When an EGPRS uplink TBF ends normally, BSC adds the number of effective data blocks received by the TBF to the counter.

C70080 Definition

Total number of NACK blocks received by EGPRS uplink TBF

Description

C70080 represents total number of NACK blocks received by EGPRS uplink TBF.

Measurement Point

When an EGPRS uplink TBF ends normally, BSC adds number of effective data blocks received by TBF to the counter.

C70081 Definition

Total number of effective data blocks sent by EGPRS downlink TBF

Description

C70081 represents total number of effective data blocks sent by EGPRS downlink TBF

Measurement Point

When an EGPRS downlink TBF ends normally, BSC adds number of effective data blocks sent by TBF to the counter.

Effective data blocks refer to NACK blocks sent first time and retransmitted.

C70082 Definition

NACK blocks sent by EGPRS downlink TBF

Description

Page 461: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 445

C70082 represents number of NACK blocks sent by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF ends normally, BSC adds number of NACK data blocks sent by the TBF to the counter.

C70083 Definition

Total number of received downlink signaling LLC frame packets

Description

C70083 represents total number of received downlink signaling LLC frame packets.

Measurement Point

C70083 increments when BSC receives a downlink signaling LLC frame.

The signaling LLC frame refers to T bit in a LLC frame when it is set to zero.

C70084 Definition

Total number of discarded downlink signaling LLC frame packets

Description

C70084 represents total number of discarded downlink signaling LLC frame packets.

Measurement Point

C70084 increments when BSC discards a downlink signaling LLC frame.

The signaling LLC frame refers to T bit in a LLC frame when it is set to zero.

C70085 Definition

Total number of received LLC frame packets of downlink GPRS data

Description

C70085 represents total number of received LLC frame packets of downlink GPRS data.

Measurement Point

C70086 increments when BSC receives a downlink GPRS signaling LLC frame.

Page 462: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

446 Confidential and Proprietary Information of ZTE CORPORATION

The signaling LLC frame refers to T bit in a LLC frame when it is set to one.

C70086 Definition

Total number of discarded LLC frame packets of downlink GPRS data

Description

C70086 represents total number of discarded LLC frame packets of downlink GPRS data.

Measurement Point

C70086 increments when BSC discards a downlink GPRS data LLC frame.

The signaling LLC frame refers to T bit in a LLC frame when it is set to one.

C70087 Definition

Total number of received LLC frame packets of downlink GPRS data

Description

C70087 represents total number of received LLC frame packets of downlink GPRS data.

Measurement Point

When BSC receives a downlink EGPRS data LLC frame, The counter increments one

The signaling LLC frame refers to T bit in a LLC frame when it is set to one.

C70088 Definition

Total number of discarded LLC frame packets of downlink GPRS data

Description

C70088 represents total number of discarded LLC frame packets of downlink GPRS data.

Measurement Point

C70088 increments when BSC discards a downlink EGPRS data LLC frame.

The signaling LLC frame refers to T bit in a LLC frame when it is set to one.

Page 463: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 447

C70089 Definition

Time of stale GPRS uplink TBF receiving window

Description

The counter represents time of stale GPRS uplink TBF receiving window

Measurement Point

C70089 increments every time when there is a stale receiving window on uplink GPRS TBF.

A stale receiving window refers to the difference between VR and VQ that equals to the set window maximum value. The received data are discarded due to its size exceeds the window range. FIGURE 37 shows algorithm of uplink TBF receiving window.

FIGURE 37 - C AL C U L AT I N G T I M E O F S T AL E U P L I N K GPRS TBF R E C E I V I N G W I N D O W

YN

N

Y

YY

N

Start

Receiving effective data block

Exceeding the window range?

(VR+WSIZE-VQ) WSIZE=WSIZE?

Does the window stale mark exist?

The counter accumulates one

Set the window stale mark End

C70090 Definition

Page 464: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

448 Confidential and Proprietary Information of ZTE CORPORATION

Time of stale uplink EGPRS TBF receiving window

Description

C70090 represents time of stale uplink EGPRS TBF receiving window

Measurement Point

C70090 increments every time when there is a stale receiving window on uplink EGPRS TBF.

A stale receiving window refers to the difference between VR and VQ that equals to the set window maximum value. The received data are discarded due to its size exceeds the window range.

C70091 Definition

Time of stale downlink GPRS TBF transmitting window

Description

C70091 represents time of stale downlink GPRS TBF transmitting window

Measurement Point

C70091 increments every time when there is a stale receiving window on downlink GPRS TBF.

A stale transmitting window refers to the difference between VS and VA that equals to the set window maximum value. Only NACK block or PENDING ACK block transmits. FIGURE 38 illustrates the algorithm.

Page 465: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 449

FIGURE 38 - C AL C U L AT I N G T I M E O F S T AL E D O W N L I N K GPRS TBF TR AN S M I T T I N G W I N D O W

N

Y

YY

N

(VR+WSIZE-VQ)%WSIZE=WSIZE?

Does the window stale mark exist?

The counter accumulates one

Set the window stale mark End

Start

Transmitting NACK block or PENDING ACK block

C70092 Definition

Time of stale downlink EGPRS TBF transmitting window

Description

C70092 represents time of stale downlink EGPRS TBF transmitting window.

Measurement Point

C70092 increments every time when there is a stale transmitting window on downlink EGPRS TBF.

A stale transmitting window refers to the difference between VS and VA that equals to the set window maximum value. Only NACK block or PENDING ACK block transmits.

C70093 Definition

Total number of abnormal release of uplink signaling TBF

Description

Page 466: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

450 Confidential and Proprietary Information of ZTE CORPORATION

C70093 represents total number of abnormal release of uplink signaling TBF.

Measurement Point

C70094 increments when an uplink signaling TBF releases abnormally.

The signaling TBF is same as before. The abnormal release refers to the releases except for all normal releases mentioned before.

C70094 Definition

Total number of abnormal release of uplink GPRS data TBF

Description

C70094 represents time of abnormal release of uplink GPRS data TBF.

Measurement Point

C70095 increments when an uplink data TBF releases abnormally.

GPRS data TBF defines as before. Abnormal release refers to the releases except for all normal releases mentioned before.

C70095 Definition

Total number of abnormal release of uplink EGPRS data TBF

Description

C70095 represents number of abnormal release of uplink EGPRS data TBF.

Measurement Point

C70095 increments when an uplink EGPRS data TBF releases abnormally.

The EGPRS data TBF is same as before. The abnormal release refers to the releases except for all normal releases mentioned before.

C70096 Definition

Total number of abnormal release of downlink signaling TBF

Description

C70096 represents total number of abnormal release of downlink signaling TBF

Measurement Point

C70096 increments when an uplink signaling TBF releases abnormally.

Page 467: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 451

The downlink signaling TBF is same as before. The abnormal release refers to the releases except for all normally releases mentioned before.

C70097 Definition

Total number of abnormal release of downlink GPRS data TBF

Description

C70097 represents total number of abnormal release of downlink GPRS data TBF.

Measurement Point

C70097 increments when a downlink data TBF releases abnormally.

The GPRS data TBF defines as before. The abnormal release refers to the releases except for all normally releases mentioned before.

C70098 Definition

Total number of abnormal release of downlink EGPRS data TBF

Description

C70098 represents total number of abnormal release of downlink EGPRS data TBF.

Measurement Point

C70098 increments when a downlink EGPRS data TBF releases abnormally.

The EGPRS data TBF is same as before. The abnormal release refers to the releases except for all normal releases mentioned before.

C70099 Definition

Number of requests for increasing Abis bandwidth by uplink TBF

Description

C70099 represents number of requests for increasing Abis bandwidth by uplink TBF.

Measurement Point

C70099 increments when the uplink TBF requests to increase Abis bandwidth.

Page 468: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

452 Confidential and Proprietary Information of ZTE CORPORATION

C70100 Definition

Number of requests for increasing Abis bandwidth by downlink TBF

Description

C70100 represents number of requests for increasing Abis bandwidth by downlink TBF

Measurement Point

C70100 increments when the downlink TBF requests to increase Abis bandwidth.

BSC requests to increase Abis bandwidth when the bandwidth is less than requirement of coding scheme.

C70101 Definition

Number of handovers from GMSK modulation to 8PSK modulation

Description

C70101 represents number of handover from GMSK modulation to 8PSK modulation.

Measurement Point

C70101 increments every time when there is a handover from GMSK to 8PSK.

C70102 Definition

Number of handover from 8PSK modulation to GMSK modulation

Description

C70102 represents number of handover from 8PSK modulation to GMSK modulation.

Measurement Point

C70102 increments every time when there is a handover 8PSK from to GMSK.

Statistics of modulation handover include uplink/downlink TBF.

C70103 Definition

Number of handovers from CS1 and CS2 to CS3 and CS4

Description

Page 469: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 453

C70104 represents number of handovers from CS1 and CS2 to CS3 and CS4.

Measurement Point

C70104 increments every time when there is a handover from CS1 and CS2 to CS3 and CS4.

Statistics of modulation handover include uplink/downlink TBF.

C70104 Definition

Number of handovers from CS3, CS4 to CS1 and CS2

Description

C70104 represents number of handovers from CS3 and CS4 to CS1 and CS2.

Measurement Point

C70104 increments every time when there is a handover from CS3 and CS4 to CS1and CS2.

Statistics of modulation handover include uplink/downlink TBF.

C70105 Definition

Total number of data packets sent to peripheral modules by BRP

Description

C70105 represents number of data packets send to peripheral modules by BRP.

Measurement Point

C70105 increments every time when BRP successfully sends a data packet to peripheral modules.

The successful sending refers to that BRP calls Ethernet communication interface and the return value is normal.

C70106 Definition

Total number of data packets that BRP receives from peripheral modules

Description

C70106 represents number of data packets that peripheral modules send to BRP.

Measurement Point

Page 470: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

454 Confidential and Proprietary Information of ZTE CORPORATION

C70106 increments every time when BRP successfully receives a data packet from peripheral modules.

C70107 Definition

Total number of data packets sent to BRP by peripheral modules

Description

C70107 represents number of data packets sent to BRP by peripheral modules.

Measurement Point

C70107 increments every time when peripheral modules send a data packet.

C70108 Definition

Total number of data packets received by peripheral modules that PCU BRP sends

Description

C70108 represents number of data packets received by BRP that are sent by peripheral modules

Measurement Point

C70108 increments when peripheral modules receive a data packet from BRP.

C70109 Definition

Number of outgoing handover from cell

Description

C70109 represents number of outgoing handover from cell

Measurement Point

C70110 increments every time when there is an outgoing handover from cell.

C70110 Definition

Number of incoming handover in cell

Description

Page 471: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 455

C70110 represents number of incoming handover in cell

Measurement Point

C70110 increments every time when there is a mobile phone incoming handover in cell.

C70111 Definition

Total number of CS1 data blocks received by packet uplink channel

Description

C70111 represents total number of CS1 data blocks received by packet uplink channel.

Measurement Point

C7011 increments every time when BSC receives CS1 data block.

C70112 Definition

Total number of CS2 data blocks received by packet uplink channel

Description

C70112 represents total number of CS2 data blocks received by packet uplink channel.

Measurement Point

C70112 increments every time when BSC receives CS2 data block.

C70113 Definition

Total number of CS3 data blocks received by packet uplink channel

Description

C70113 represents total number of CS3 data blocks received by packet uplink channel.

Measurement Point

C70113 increments every time when BSC receives CS3 data block.

C70114 Definition

Total number of CS4 data blocks received by packet uplink channel

Description

Page 472: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

456 Confidential and Proprietary Information of ZTE CORPORATION

C70114 represents total number of CS4 data blocks received by packet uplink channel.

Measurement Point

C70114 increments every time when BSC receives CS4 data block.

C70115 Definition

Total number of CS1 data blocks sent by packet downlink channel

Description

C70115 represents total number of CS1 data blocks sent by packet downlink channel.

Measurement Point

C70115 increments every time when BSC sends CS1 data block.

C70116 Definition

Total number of CS2 data blocks sent by packet downlink channel

Description

C70116 represents total number of CS2 data blocks sent by packet downlink channel.

Measurement Point

C70116 increments every time when BSC sends CS2 data block.

C70117 Definition

Total number of CS3 data blocks sent by packet downlink channel

Description

C70117 represents total number of CS3 data blocks sent by packet downlink channel.

Measurement Point

C70117 increments every time when BSC sends CS3 data block.

C70118 Definition

Total number of CS4 data blocks sent by packet downlink channel

Description

Page 473: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 457

C70118 represents total number of CS4 data blocks sent by packet downlink channel.

Measurement Point

C70118 increments every time when BSC sends CS4 data block.

C70119 Definition

Minimum number of available PDCH

Description

C70119 represents minimum number of available PDCH

Measurement Point

C70119 records minimum number of available PDCH during the measurement cycle (every fifteen minutes).

C70120 Definition

Total number of uplink blocks received by uplink channel (including DUMMY block)

Description

C70120 represents total number of uplink blocks received by uplink channel (including DUMMY block)

Measurement Point

C70120 increments when BSC receives block. When there is number actual PS service, the DUMMY block records in the counter.

C70121 Definition

Total number of downlink blocks sent by downlink channel (including DUMMY block)

Description

C70121 represents total number of downlink blocks sent by downlink channel (including DUMMY block).

Measurement Point

C70121 increments when BSC sends block. When there is number actual PS service, the DUMMY block records in the counter.

Table 48 shows the calculation and description of the Counters C70501~C70536.

Page 474: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

458 Confidential and Proprietary Information of ZTE CORPORATION

TAB L E 48 C O U N T E R S C70501~C70536

Counter Number. Description Calculation instruction Remark

C70501 Success ratio of uplink TBF link establishment

(C70042+C70055+C70069)/ (C70040×100)

Two-digit-decimal precision; percentage representation

C70502 Success ratio of downlink TBF link establishment

(C70043+C70057+C70071)/ (C70041×100)

Two-digit-decimal precision; percentage representation

C70503 Percentage of uplink signaling TBF in uplink TBF

C70042/(C70042+C70055+ C70069)×100

Two-digit-decimal precision; percentage representation

C70504 Percentage of downlink signaling TBF in downlink TBF

C70043/(C70043+C70057+ C70071)×100

Two-digit-decimal precision; percentage representation

C70505 Percentage of GPRS uplink data TBF in uplink data TBF

C70055/(C70055+C70069)×100

two-digit-decimal precision, percentage representation

C70506

Percentage of GPRS downlink data TBF in downlink data TBF

C70057/(C70057+C70071)×100

two-digit-decimal precision, percentage representation

Counter Number. Description Calculation instruction Remark

C70507 Percentage of uplink packet channel RLC signaling overhead

C70044/(C70044+C70045)×100

two-digit-decimal precision, percentage representation

C70508

Percentage of downlink packet channel RLC signaling overhead

C70046/(C70046+C70047)

two-digit-decimal precision, percentage representation

C70509 Uplink packet channel utilization ratio

(C70044+C70045)/C70120×100

two-digit-decimal precision, percentage representation

C70510 Downlink packet channel utilization ratio

(C70046+C700474)/C70121 ×

100

two-digit-decimal precision, percentage representation

C70511 Abis bandwidth utilization ratio

C70048/(C70046+C70047)×100

two-digit-decimal precision, percentage representation

C70512 Cell RLC layer uplink data throughput

C70050×8/(60×60)(bps) -

Page 475: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 459

C70513

Average RLC uplink data throughput carried on each channel

C70050×8/(60×60×C70019)(bps) -

C70514 Cell RLC layer downlink data throughput

C70049×8/(60×60)(bps) -

C70515

Average RLC downlink data throughput carried on each channel

C70049×8/(60×60×C70019)(bps) -

C70516

Percentage of uplink GPRS data TBF established on PACCH

C70056/ C70055×100

two-digit-decimal precision, percentage representation

C70517

Percentage of downlink GPRS data TBF established on PACCH

C70058/ C70057×100

two-digit-decimal precision, percentage representation

C70518 Average rate of GPRS uplink data TBF

C70059×1000×8/(C70061×20) -

C70519 Average rate of GPRS downlink data TBF

C70062×1000×8/(C70064×20) -

C70520 GPRS RLC uplink block retransmission ratio

C70066/ C70065×100

two-digit-decimal precision, percentage representation

C70521 GPRS RLC downlink block retransmission ratio

C70068/ C70067×100

two-digit-decimal precision, percentage representation

C70522

Percentage of uplink EGPRS data TBF established on PACCH

C70070/ C70069×100

two-digit-decimal precision, percentage representation

C70523

Percentage of downlink EGPRS data TBF established on PACCH

C70072/ C70071×100

two-digit-decimal precision, percentage representation

C70524 Average rate of EGPRS uplink data TBF (felt by user)

C70073×1000×8/(C70075×20) -

C70525

Average rate of EGPRS downlink data TBF (felt by user)

C70076×1000×8/(C70078×20) -

Page 476: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

460 Confidential and Proprietary Information of ZTE CORPORATION

C70526 EGPRS RLC uplink block retransmission ratio

C70080/ C70079×100

two-digit-decimal precision, percentage representation

C70527 EGPRS RLC downlink block retransmission ratio

C70082/ C70081×100

two-digit-decimal precision, percentage representation

C70528 Downlink LLC signaling frame discarding ratio

C70084/ C70083×100

two-digit-decimal precision, percentage representation

C70529 Downlink GPRS data frame discarding ratio

C70086/ C70085×100

two-digit-decimal precision, percentage representation

C70530 Downlink EGPRS data frame discarding ratio

C70088/ C70087×100

two-digit-decimal precision, percentage representation

C70531 Uplink signaling TBF failure ratio

C70093/ C70042×100

two-digit-decimal precision, percentage representation

C70532 Uplink GPRS data TBF failure ratio

C70094/ C70055×100

two-digit-decimal precision, percentage representation

C70533 Uplink EGPRS data TBF failure ratio

C70095/ C70069×100

two-digit-decimal precision, percentage representation

C70534 Downlink signaling TBF failure ratio

C70096/ C70043×100

two-digit-decimal precision, percentage representation

C70535 Downlink GPRS data TBF failure ratio

C70097/ C70057×100

two-digit-decimal precision, percentage representation

C70536 Downlink EGPRS data TBF failure ratio

C70098/ C70071×100

two-digit-decimal precision, percentage representation

Following is specification for basic measurement based on BSC.

C90001 Definition

Total number of uplink data packets carried by BRCH

Page 477: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 461

Description

C90001 represents total number of uplink data packets carried by BRCH.

Measurement Point

C90001 increments when BSC sends the uplink block on BRCH.

C90002 Definition

Total number of downlink data packets carried by BRCH

Definition

C90001 represents total number of downlink data packets carried by BRCH.

Measurement Point

C90002 increments when BSC receives the downlink block on BRCH.

C90003 Definition

Number of interruption due to BRCH receiving failure

Description

C90003 represents number of interruption due to BRCH receiving failure.

Measurement Point

C90003 increments when there is data interruption due to BRCH receiving failure.

C90004 Definition

Total number of data packets sent to FRP by BRP

Description

C90004 represents number of data packets send to FRP by BRP.

Measurement Point

C90004 increments when BRP successfully sends a data packet to FRP.

C90005 Definition

Total number of data packets received by BRP sent by FRP

Page 478: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

462 Confidential and Proprietary Information of ZTE CORPORATION

Description

C90005 represents number of data packets received by BRP that are sent by FRP

Measurement Point

C90005 increments when BRP receives a data packet from FRP.

C90006 Definition

Total number of data packets sent to BRP by FRP

Description

C90006 represents number of data packets send to BRP by FRP

Measurement Point

C90006 increments when FRP successfully sends a data packet to BRP.

C90007 Definition

Total number of data packets received by FRP sent by BRP

Description

C90007 represents number of data packets received by FRP that are sent by BRP

Measurement Point

C90007 increments when FRP receives a data packet from BRP.

PS Traffic Counters PCU records the values of Traffic Statistic Counters and samples every five minutes. The statistic unit of PS traffic statistic counters is cell. Table 49 shows the traffic statistic counters.

TAB L E 49 TR AF F I C S T AT I S T I C C O U N T E R S

Counter Number. Definition

C60001 Number of PPCH used

C60002 Total number of PRACH

C60003 Number of PAGCH used

C60004 Number of handover from CS1 to CS2

C60005 Number of handover from CS2 to CS1

Page 479: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 463

Counter Number. Definition

C60006 Uplink power control

C60007 Number of attempt of increasing timeslot of dynamic Abis-interface

C60008 Number of successful increasing timeslot of dynamic Abis-interface

C60009 Number of attempt of decreasing timeslot of dynamic Abis-interface

C60010 Number of successful decreasing timeslot of dynamic Abis-interface

C60011 Total number of CS1 data blocks received by packet uplink channel

C60012 Total number of CS2 data blocks received by packet uplink channel

C60013 Total number of CS3 data blocks received by packet uplink channel

C60014 Total number of CS4 data blocks received by packet uplink channel

C60015 Total number of MCS1 data blocks received by packet uplink channel

C60016 Total number of MCS2 data blocks received by packet uplink channel

C60017 Total number of MCS3 data blocks received by packet uplink channel

C60018 Total number of MCS4 data blocks received by packet uplink channel

C60019 Total number of MCS5 data blocks received by packet uplink channel

C60020 Total number of MCS6 data blocks received by packet uplink channel

C60021 Total number of MCS7 data blocks received by packet uplink channel

C60022 Total number of MCS8 data blocks received by packet uplink channel

C60023 Total number of MCS9 data blocks received by packet uplink channel

C60024 Total number of CS1 data blocks received by packet downlink channel

C60025 Total number of CS2 data blocks received by packet downlink channel

C60026 Total number of CS3 data blocks received by packet downlink channel

C60027 Total number of CS4 data blocks received by packet downlink channel

C60028 Total number of MCS1 data blocks received by packet downlink channel

Page 480: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

464 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Definition

C60029 Total number of MCS2 data blocks received by packet downlink channel

C60030 Total number of MCS3 data blocks received by packet downlink channel

C60031 Total number of MCS4 data blocks received by packet downlink channel

C60032 Total number of MCS5 data blocks received by packet downlink channel

C60033 Total number of MCS6 data blocks received by packet downlink channel

C60034 Total number of MCS7 data blocks received by packet downlink channel

C60035 Total number of MCS8 data blocks received by packet downlink channel

C60036 Total number of MCS9 data blocks received by packet downlink channel

C60037 Total number of NACK blocks with CS1 coding scheme in GPRS uplink TBF

C60038 Total number of NACK blocks with CS2 coding scheme in GPRS uplink TBF

C60039 Total number of NACK blocks with CS3 coding scheme in GPRS uplink TBF

C60040 Total number of NACK blocks with CS4 coding scheme in GPRS uplink TBF

C60041 Total number of NACK blocks with CS1 coding scheme in GPRS downlink TBF

C60042 Total number of NACK blocks with CS2 coding scheme in GPRS uplink TBF

C60043 Total number of NACK blocks with CS3 coding scheme in GPRS uplink TBF

C60044 Total number of NACK blocks with CS4 coding scheme in GPRS uplink TBF

C60045 Total number of NACK blocks with MCS1 coding scheme in EGPRS uplink TBF

C60046 Total number of NACK blocks with MCS2 coding scheme in EGPRS uplink TBF

C60047 Total number of NACK blocks with MCS3 coding scheme in EGPRS uplink TBF

C60048 Total number of NACK blocks with MCS4 coding scheme in EGPRS uplink TBF

C60049 Total number of NACK blocks with MCS5 coding scheme in EGPRS uplink TBF

C60050 Total number of NACK blocks with MCS6 coding scheme in EGPRS uplink TBF

C60051 Total number of NACK blocks with MCS7 coding scheme in EGPRS uplink TBF

Page 481: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 465

Counter Number. Definition

C60052 Total number of NACK blocks with MCS8 coding scheme in EGPRS uplink TBF

C60053 Total number of NACK blocks with MCS9 coding scheme in EGPRS uplink TBF

C60054 Total number of NACK blocks with MCS1 coding scheme in EGPRS downlink TBF

C60055 Total number of NACK blocks with MCS2 coding scheme in EGPRS downlink TBF

C60056 Total number of NACK blocks with MCS3 coding scheme in EGPRS downlink TBF

C60057 Total number of NACK blocks with MCS4 coding scheme in EGPRS downlink TBF

C60058 Total number of NACK blocks with MCS5 coding scheme in EGPRS downlink TBF

C60059 Total number of NACK blocks with MCS6 coding scheme in EGPRS downlink TBF

C60060 Total number of NACK blocks with MCS7 coding scheme in EGPRS downlink TBF

C60061 Total number of NACK blocks with MCS8 coding scheme in EGPRS downlink TBF

C60062 Total number of NACK blocks with MCS9 coding scheme in EGPRS downlink TBF

C60063 Value of N3101 counter

C60064 Value of N3105 counter

C60065 Number of abnormal releases of uplink TBF due to not receiving resource request

C60066 Number of abnormal releases of uplink signaling TBF due to N3101 overflow

C60067 Number of abnormal releases of uplink signaling TBF due to N3103 overflow

C60068 Number of forced releases of uplink signaling TBF

C60069 Number of abnormal releases of uplink signaling TBF due to dead suspending of the instance

C60070 Number of abnormal releases of uplink signaling TBF due to internal error

C60071 Number of abnormal releases of uplink GPRS TBF due to N3101 overflow

C60072 Number of abnormal releases of uplink GPRS TBF due to N3103 overflow

C60073 Number of forced releases of uplink GPRS TBF

C60074 Number of abnormal releases of uplink GPRS TBF due to dead suspending of the instance

C60075 Number of abnormal releases of uplink GPRS TBF due to internal error

Page 482: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

466 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Definition

C60076 Number of abnormal releases of uplink EGPRS TBF due to N3101 overflow

C60077 Number of abnormal releases of uplink EGPRS TBF due to N3103 overflow

C60078 Number of forced releases of uplink EGPRS TBF

C60079 Number of abnormal releases of uplink EGPRS TBF due to dead suspending of the instance

C60080 Number of abnormal releases of uplink GPRS TBF due to internal error

C60081 Number of abnormal releases of downlink signaling TBF due to POLL overflow

C60082 Number of abnormal releases of downlink signaling TBF due to N3105 overflow

C60083 Number of forced releases of downlink signaling TBF

C60084 Number of abnormal releases of downlink signaling TBF due to dead suspending of the instance

C60085 Number of abnormal releases of downlink signaling TBF due to internal error

C60086 Number of abnormal releases of downlink GPRS data TBF due to POLL overflow

C60087 Number of abnormal releases of downlink GPRS data TBF due to N3105 overflow

C60088 Number of forced releases of downlink GPRS data TBF

C60089 Number of abnormal releases of downlink GPRS data TBF due to dead suspending of the instance

C60090 Number of abnormal releases of downlink GPRS data TBF due to internal error

C60091 Number of abnormal releases of downlink EGPRS data TBF due to POLL overflow

C60092 Number of abnormal releases of downlink EGPRS data TBF due to N3105 overflow

C60093 Number of forced releases of downlink EGPRS data TBF

C60094 Number of abnormal releases of downlink EGPRS data TBF due to dead suspending of the instance

C60095 Number of abnormal releases of downlink GPRS data TBF due to internal error

PS Traffic Counters Explanation C60001 Definition

Number of PPCH used

Page 483: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 467

Description

C60001 represents number of PPCH currently in use during the statistic period.

Measurement Point

C60001 increments every time when BSC uses PPCH to send paging message or BSC sends downlink assignment.

C60002 Definition

Total number of PRACH

Description

C60002 represents number of PRACH currently in use during the statistic period.

Measurement Point

C60002 increments every time when BSC receives the uplink channel request send on PRACHJ

C60003 Definition

Number of PAGCH used

Description

C60003 represents number of PAGCH, currently in use during the statistic period.

Measurement Point

C60003 increments every time when BSC uses PAGCH to send the uplink assignment message.

C60004 Definition

Number of handover from CS1 to CS2

Description

C60005 represents number of TBF coding scheme’s handover from CS1 to CS2.

Measurement Point

C60005 increments every time when BSC initiates a coding scheme handover from CS1 to CS2 according to current channel status and wireless environment.

Page 484: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

468 Confidential and Proprietary Information of ZTE CORPORATION

C60005 Number of handover from CS2 to CS1

Description

C60005 represents number of TBF coding scheme’s handover from CS2 to CS1.

Measurement Point

C60005 increments every time when BSC initiates a coding scheme handover from CS2 to CS1 according to current channel status and wireless environment.

C60006 Definition

Uplink power control

Description

C60006 represents number of uplink power control of the mobile phone by BSC in the uplink TBF procedure.

Measurement Point

C60006 increments every time when BSC initiates an uplink power control according to current channel status.

C60007 Definition

Number of attempt to increase timeslot of dynamic Abis-interface

Description

C60007 represents number of attempt to increase timeslot of dynamic Abis-interface.

Measurement Point

C60007 increments every time when BRP service module on PCU initiates an increasing of dynamic Abis-interface.

C60008 Definition

Number of successful increasing timeslot of dynamic Abis-interface

Description

C6008 represents number of successful increasing timeslot of dynamic Abis communication link.

Measurement Point

Page 485: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 469

C60008 increments every time when BRP service module on PCU successfully initiates an increasing of dynamic Abis-interface.

C60009 Definition

Number of attempt of decreasing timeslot of dynamic Abis-interface

Description

C60009 represents number of attempt of increasing timeslot of dynamic Abis communication link.

Measurement Point

C60009 increments every time when BRP service module on PCU initiates a decreasing of dynamic Abis-interface.

C60010 Definition

Number of successful decreasing timeslot of dynamic Abis-interface

Description

C60010 represents number of successful decreasing timeslot of dynamic Abis communication link.

Measurement Point

C60010 increments every time when BRP service module on PCU successfully initiates a decreasing of dynamic Abis-interface.

C60011 Definition

Total number of CS1 data blocks received by packet uplink channel

Description

C60011 represents number of CS1 data blocks received by packet uplink channel.

Measurement Point

C60011 increments every time when BSC receives an effective CS1 data block.

The effective data block refers to data block that combines into LLC frame.

C60012 Definition

Total number of CS2 data blocks received by packet uplink channel

Page 486: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

470 Confidential and Proprietary Information of ZTE CORPORATION

Description

C60012 represents number of CS2 data blocks received by packet uplink channel.

Measurement Point

C60012 increments every time when BSC receives an effective CS2 data block.

C60013 Definition

Total number of CS3 data blocks received by packet uplink channel

Description

C60013 represents number of CS3 data blocks received by packet uplink channel.

Measurement Point

C60013 increments every time when BSC receives an effective CS3 data block.

C60014 Definition

Total number of CS4 data blocks received by packet uplink channel

Description

C60014 represents number of CS4 data blocks received by packet uplink channel.

Measurement Point

C60014 increments every time when BSC receives an effective CS4 data block.

C60015 Definition

Total number of MCS1 data blocks received by packet uplink channel

Description

C60015 represents number of MCS1 data blocks received by packet uplink channel.

Measurement Point

C60015 increments every time when BSC receives an effective MCS1 data block.

Page 487: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 471

C60016 Definition

Total number of MCS2 data blocks received by packet uplink channel

Description

C60016 represents number of MCS2 data blocks received by packet uplink channel.

Measurement Point

C60016 increments every time when BSC receives an effective MCS2 data block.

C60017 Definition

Total number of MCS3 data blocks received by packet uplink channel

Description

C6007 represents number of MCS3 data blocks received by packet uplink channel.

Measurement Point

C60017 increments every time when BSC receives an effective MCS3 data block.

C60018 Definition

Total number of MCS4 data blocks received by packet uplink channel

Description

C60018 represents number of MCS4 data blocks received by packet uplink channel.

Measurement Point

C60018 increments every time when BSC receives an effective MCS4 data block.

C60019 Definition

Total number of MCS5 data blocks received by packet uplink channel

Definition

C60019 represents number of MCS5 data blocks received by packet uplink channel.

Page 488: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

472 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C60019 increments every time when BSC receives an effective MCS5 data block, The counter increments one.

C60020 Definition

Total number of MCS6 data blocks received by packet uplink channel

Definition

C60020 represents number of MCS6 data blocks received by packet uplink channel.

Measurement Point

C60020 increments every time when BSC receives an effective MCS6 data block.

C60021 Definition

Total number of MCS7 data blocks received by packet uplink channel

Description

C60021 represents number of MCS7 data blocks received by packet uplink channel.

Measurement Point

C60021 increments every time when BSC receives an effective MCS7 data block.

C60022 Definition

Total number of MCS8 data blocks received by packet uplink channel

Description

C60022 represents number of MCS8 data blocks received by packet uplink channel.

Measurement Point

C60022 increments every time when BSC receives an effective MCS8 data block.

C60023 Definition

Total number of MCS9 data blocks received by packet uplink channel

Page 489: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 473

Description

C60023 represents number of MCS9 data blocks received by packet uplink channel.

Measurement Point

C60023 increments every time when BSC receives an effective MCS9 data block.

C60024 Definition

Total number of CS1 data blocks sent by packet downlink channel

Definition

C60024 represents number of CS1 data blocks sent by packet downlink channel.

Measurement Point

C60024 increments every time when BSC sends an effective CS1 data block, the counter increments one.

The effective data block refers to data block, which system writes successfully to channel data buffer.

C60025 Definition

Total number of CS2 data blocks sent by packet downlink channel

Description

C60025 represents number of CS2 data blocks sent by packet downlink channel.

Measurement Point

C60025 increments every time when BSC sends an effective CS2 data block.

C60026 Definition

Total number of CS3 data blocks sent by packet downlink channel

Description

C60026 represents number of CS3 data blocks sent by packet downlink channel.

Measurement Point

Page 490: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

474 Confidential and Proprietary Information of ZTE CORPORATION

C60026 increments every time when BSC sends an effective CS3 data block.

C60027 Definition

Total number of CS4 data blocks sent by packet downlink channel

Description

C60027 represents number of CS4 data blocks sent by packet downlink channel.

Measurement Point

C60027 increments every time when BSC sends an effective CS4 data block.

C60028 Definition

Total number of MCS1 data blocks sent by packet downlink channel

Definition

C60028 represents number of MCS1 data blocks sent by packet downlink channel.

Measurement Point

C60028 increments every time when BSC sends an effective MCS1 data block.

C60029 Definition

Total number of MCS2 data blocks sent by packet downlink channel

Description

C60029 represents number of MCS2 data blocks sent by packet downlink channel.

Measurement Point

C60029 increments every time when BSC sends an effective MCS2 data block.

C60030 Definition

Total number of MCS3 data blocks sent by packet downlink channel

Description

Page 491: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 475

C60030 represents number of MCS3 data blocks sent by packet downlink channel.

Measurement Point

C60030 increments every time when BSC sends an effective MCS3 data block.

C60031 Definition

Total number of MCS4 data blocks sent by packet downlink channel

Description

C60031 represents number of MCS4 data blocks sent by packet downlink channel.

Measurement Point

C60031 increments every time when BSC sends an effective MCS4 data block.

C60032 Definition

Total number of MCS5 data blocks sent by packet downlink channel

Description

C60032 represents number of MCS5 data blocks sent by packet downlink channel.

Measurement Point

C60032 increments every time when BSC sends an effective MCS5 data block.

C60033 Definition

Total number of MCS6 data blocks sent by packet downlink channel

Description

C60033 represents number of MCS6 data blocks sent by packet downlink channel.

Measurement Point

C60033 increments every time when BSC sends an effective MCS6 data block.

C60034 Definition

Page 492: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

476 Confidential and Proprietary Information of ZTE CORPORATION

Total number of MCS7 data blocks sent by packet downlink channel

Description

C60034 represents number of MCS7 data blocks sent by packet downlink channel.

Measurement Point

C60034 increments every time when BSC sends an effective MCS7 data block.

C60035 Definition

Total number of MCS8 data blocks sent by packet downlink channel

Description

C60035 represents number of MCS8 data blocks sent by packet downlink channel.

Measurement Point

C60035 increments every time when BSC sends an effective MCS8 data block.

C60036 Definition

Total number of MCS9 data blocks sent by packet downlink channel

Description

C60036 represents number of MCS9 data blocks sent by packet downlink channel.

Measurement Point

C60036 increments every time when BSC sends an effective MCS9 data block.

C60037 Definition

Total number of NACK blocks with CS1 coding scheme in GPRS uplink TBF

Description

C60037 represents number of CS1 NACK blocks received by GPRS uplink TBF.

Page 493: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 477

Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS1 NACK data blocks received by TBF to C60037.

The NACK data block refers to a data block that locates between VQ and VR and combines into LLC frame (including VQ).

C60038 Definition

Total number of NACK blocks with CS2 coding scheme in GPRS uplink TBF

Description

C60038 represents number of CS2 NACK blocks received by GPRS uplink TBF.

Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS2 NACK data blocks received by TBF to counter.

C60039 Definition

Total number of NACK blocks with CS3 coding scheme in GPRS uplink TBF

Description

C60039 represents number of CS3 NACK blocks received by GPRS uplink TBF.

Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS3 NACK data blocks received by TBF to C60039.

C60040 Definition

Total number of NACK blocks with CS4 coding scheme in GPRS uplink TBF

Description

C60040 represents number of CS4 NACK blocks received by GPRS uplink TBF.

Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS4 NACK data blocks received by the TBF to the counter.

Page 494: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

478 Confidential and Proprietary Information of ZTE CORPORATION

C60041 Definition

Total number of NACK blocks with CS1 coding scheme in GPRS downlink TBF

Description

C60041 represents number of CS1 NACK blocks received by GPRS downlink TBF.

Measurement Point

When a GPRS downlink TBF normally ends, BSC adds the number of CS1 NACK data blocks sent by the TBF t C60041.

C60042 Definition

Total number of NACK blocks with CS2 coding scheme in GPRS downlink TBF

Description

C60042 represents number of CS2 NACK blocks received by GPRS downlink TBF.

Measurement Point

When a GPRS downlink TBF normally ends, BSC will add the number of CS2 NACK data blocks sent by TBF to C60042.

C60043 Definition

Total number of NACK blocks with CS3 coding scheme in GPRS downlink TBF

Description

C60043 represents number of CS3 NACK blocks received by GPRS downlink TBF.

Measurement Point

When a GPRS downlink TBF normally ends, BSC will adds the number of CS3 NACK data blocks sent by TBF to C60043.

C60044 Definition

Total number of NACK blocks with CS4 coding scheme in GPRS downlink TBF

Description

Page 495: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 479

C60044 represents number of CS4 NACK blocks received by GPRS downlink TBF.

Measurement Point

When a GPRS downlink TBF normally ends, BSC adds the number of CS4 NACK data blocks sent by TBF to C60044.

C60045 Definition

Total number of MCS1 NACK blocks received by EGPRS uplink TBF

Description

C60045 represents number of MCS1 NACK blocks received by EGPRS uplink TBF.

Measurement Point

When EGPRS uplink TBF normally ends, BSC adds the value number of MCS1 NACK data blocks received by TBF to C60045

Coding scheme belonging to MSC1 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60046 Definition

Total number of MCS2 NACK blocks received by EGPRS uplink TBF

Description

C60046 represents number of MCS2 NACK blocks received by EGPRS uplink TBF.

Measurement Point

When EGPRS uplink TBF normally ends, BSC adds the number of MCS2 NACK data blocks received by TBF to C60046.

Coding scheme belonging to MSC2 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60047 Definition

Total number of MCS3 NACK blocks received by EGPRS uplink TBF

Description

C60047 represents number of MCS3 NACK blocks received by EGPRS uplink TBF.

Measurement Point

Page 496: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

480 Confidential and Proprietary Information of ZTE CORPORATION

When an EGPRS uplink TBF normally ends, BSC adds the number of MCS3 NACK data blocks received by TBF to C60047.

Coding scheme belonging to MSC3 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60048 Definition

Total number of MCS4 NACK blocks received by EGPRS uplink TBF

Description

C60048 represents number of MCS4 NACK blocks received by EGPRS uplink TBF.

Measurement Point

When an EGPRS uplink TBF normally ends, BSC adds the number of MCS4 NACK data blocks received by the TBF to C60048.

Coding scheme belonging to MSC4 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60049 Definition

Total number of MCS5 NACK blocks received by EGPRS uplink TBF

Description

C60049 represents number of MCS5 NACK blocks received by EGPRS uplink TBF.

Measurement Point

When an EGPRS uplink TBF normally ends, BSC adds the number of MCS5 NACK data blocks received by TBF to C60049.

Coding scheme belonging to MSC5 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60050 Definition

Total number of MCS6 NACK blocks received by EGPRS uplink TBF

Description

C60050 represents number of MCS6 NACK blocks received by EGPRS uplink TBF.

Measurement Point

Page 497: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 481

When an EGPRS uplink TBF normally ends, BSC will add the number of MCS6 NACK data blocks received by TBF to C60050.

Coding scheme belonging to MSC6 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60051 Definition

Total number of MCS7 NACK blocks received by EGPRS uplink TBF

Description

C60051 represents number of MCS7 NACK blocks received by EGPRS uplink TBF.

Measurement Point

When an EGPRS uplink TBF normally ends, BSC adds the number of MCS7 NACK data blocks received by TBF to C60051.

Coding scheme belonging to MSC7 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60052 Definition

Total number of MCS8 NACK blocks received by EGPRS uplink TBF

Description

C60052 represents number of MCS8 NACK blocks received by EGPRS uplink TBF.

Measurement Point

When an EGPRS uplink TBF normally ends, BSC will add the number of MCS8 NACK data blocks received by the TBF to C60052.

Coding scheme belonging to MSC8 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60053 Definition

Total number of MCS9 NACK blocks received by EGPRS uplink TBF

Description

C60053 represents number of MCS9 NACK blocks received by EGPRS uplink TBF.

Measurement Point

Page 498: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

482 Confidential and Proprietary Information of ZTE CORPORATION

When an EGPRS uplink TBF normally ends, BSC adds the number of MCS9 NACK data blocks received by TBF to C60053.

Coding scheme belonging to MSC9 NACK data block refers to data block, which has SPB not equal to 0x01 or 0x10 and locates between VQ and VR. It combines into LLC frame (including VQ).

C60054 Total number of NACK blocks with MCS1 coding scheme in EGPRS downlink TBF

Description

C60054 represents number of MCS8 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS1 NACK data blocks sent by the TBF to C60055.

C60055 Definition

Total number of NACK blocks with MCS2 coding scheme in EGPRS downlink TBF

Description

C60055 represents number of MCS2 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS2 NACK data blocks sent by the TBF to C60055.

C60056 Definition

Total number of NACK blocks with MCS3 coding scheme in EGPRS downlink TBF

Description

C60056 represents number of MCS3 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS3 NACK data blocks sent by TBF to C60056.

Page 499: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 483

C60057 Definition

Total number of NACK blocks with MCS4 coding scheme in EGPRS downlink TBF

Description

C60057 represents number of MCS4 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS4 NACK data blocks sent by TBF to C60057.

C60058 Definition

Total number of NACK blocks with MCS5 coding scheme in EGPRS downlink TBF

Description

C60058 represents number of MCS5 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS5 NACK data blocks sent by TBF to. C60058

C60059 Definition

Total number of NACK blocks with MCS6 coding scheme in EGPRS downlink TBF

Description

C60059 represents number of MCS6 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS6 NACK data blocks sent by TBF to C60059.

C60060 Definition

Total number of NACK blocks with MCS7 coding scheme in EGPRS downlink TBF

Description

Page 500: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

484 Confidential and Proprietary Information of ZTE CORPORATION

C60060 represents number of MCS7 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS7 NACK data blocks sent by TBF to C60060.

C60061 Definition

Total number of NACK blocks with MCS8 coding scheme in EGPRS downlink TBF

Description

C60061 represents number of MCS8 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS8 NACK data blocks sent by TBF to C60060.

C60062 Definition

Total number of NACK blocks with MCS9 coding scheme in EGPRS downlink TBF

Description

C60062 represents number of MCS9 NACK blocks received by EGPRS downlink TBF.

Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of MCS9 NACK data blocks sent by TBF to C60062.

C60063 Definition

Value of N3101 counter

Description

C60063 represents value of N3101 counter.

Measurement Point

When N3101 clears to zero, BSC adds the value of N3101 to C60063.

C60064 Definition

Page 501: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 485

Value of N3105 counter

Description

C60064 represents value of N3105 counter.

Measurement Point

When N3105 clears to zero, BSC adds the value of N3105 to C60064.

C60065 Definition

Number of abnormal releases of uplink TBF due to not receiving resource request

Description

C60065 represents number of abnormal releases of uplink TBF due to not receiving resource request.

Measurement Point

C60065 increments when BSC des not receive resource request on the block that should receive resource request.

C60066 Definition

Number of abnormal releases of uplink signaling TBF due to N3101 overflow

Description

C60066 represents number of abnormal releases of uplink signaling TBF due to N3101 overflow.

Measurement Point

C60066 increments when uplink-signaling TBF releases abnormally due to N3101 overflow.

C60067 Definition

Number of abnormal releases of uplink signaling TBF due to N3103 overflow

Description

C60067 represents number of abnormal releases of uplink signaling TBF due to N3103 overflow.

Measurement Point

Page 502: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

486 Confidential and Proprietary Information of ZTE CORPORATION

C60067 increments when uplink-signaling TBF releases abnormally due to N3103 overflow.

C60068 Definition

Number of abnormal releases of uplink signaling TBF due to forced release

Description

C60068 represents number of abnormal releases of uplink signaling TBF due to forced release.

Measurement Point

C60065 increments when BSC abnormally releases the uplink signaling TBF due to receiving the forced release message.

C60069 Definition

Number of abnormal releases of uplink signaling TBF due to dead suspending of the instance

Description

C60069 represents number of abnormal releases of uplink signaling TBF due to dead suspending of the instance.

Measurement Point

C60069 increments when BSC abnormally releases the uplink signaling TBF due to dead suspending of the instance.

C60070 Definition

Number of abnormal releases of uplink signaling TBF due to internal error

Description

C60070 represents number of abnormal releases of uplink signaling TBF due to internal error.

Measurement Point

C60070 increments when BSC abnormally releases the uplink signaling TBF due to internal error.

C60071 Definition

Page 503: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 487

Number of abnormal releases of uplink GPRS data TBF due to N3101 overflow

Description

C60071 represents number of abnormal releases of uplink GPRS data TBF due to N3101 overflow.

Measurement Point

C60071 increments when BSC abnormally releases the uplink GPRS data TBF due to N3101 overflow.

C60072 Definition

Number of abnormal releases of uplink GPRS data TBF due to N3103 overflow

Description

C60072 represents number of abnormal releases of uplink GPRS data TBF due to N3103 overflow.

Measurement Point

C60072 increments when BSC abnormally releases the uplink GPRS data TBF due to N3103 overflow.

C60073 Definition

Number of abnormal releases of uplink GPRS data TBF due to forced release

Description

C60073 represents number of abnormal releases of uplink GPRS data TBF due to forced release.

Measurement Point

C60073 increments when BSC abnormally releases the uplink GPRS data TBF due to receiving the forced release message.

C60074 Definition

Number of abnormal releases of uplink GPRS data TBF due to dead suspending of the instance

Description

C60074 represents number of abnormal releases of uplink GPRS data TBF due to dead suspending of the instance.

Page 504: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

488 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C60074 increments when BSC abnormally releases the uplink GPRS data TBF due to dead suspending of the instance.

C60075 Definition

Number of abnormal releases of uplink GPRS data TBF due to internal error

Description

C60075 represents number of abnormal releases of uplink GPRS data TBF due to internal error.

Measurement Point

C60075 increments when BSC abnormally releases the uplink GPRS data TBF due to internal error.

C60076 Definition

Number of abnormal releases of uplink EGPRS data TBF due to N3101 overflow

Description

C60076 represents number of abnormal releases of uplink EGPRS data TBF due to N3101 overflow.

Measurement Point

C60076 increments when BSC abnormally releases the uplink EGPRS data TBF due to N3101 overflow.

C60077 Definition

Number of abnormal releases of uplink EGPRS data TBF due to N3103 overflow

Description

C60077 represents number of abnormal releases of uplink EGPRS data TBF due to N3103 overflow.

Measurement Point

C60077 increments when BSC abnormally releases the uplink EGPRS data TBF due to N3103 overflow.

Page 505: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 489

C60078 Definition

Number of abnormal releases of uplink EGPRS data TBF due to forced release

Description

C60078 represents number of abnormal releases of uplink EGPRS data TBF due to forced release.

Measurement Point

C60078 increments when BSC abnormally releases the uplink EGPRS data TBF due to forced release.

C60079 Definition

Number of abnormal release of uplink EGPRS data TBF due to dead suspending of the instance

Description

C60079 represents number of abnormal releases of uplink EGPRS data TBF due to dead suspending of the instance.

Measurement Point

C60079 increments when BSC abnormally releases the uplink EGPRS data TBF due to dead suspending of the instance.

C60080 Definition

Number of abnormal releases of uplink EGPRS data TBF due to internal error

Description

C60080 represents number of abnormal releases of uplink EGPRS data TBF due to internal error.

Measurement Point

C60080 increments when BSC abnormally releases the uplink EGPRS data TBF due to internal error.

The internal error refers to abnormal release case except for those such as forced release, timer overflow, or counter overflow, etc.

C60081 Definition

Page 506: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

490 Confidential and Proprietary Information of ZTE CORPORATION

Number of abnormal releases of downlink signaling TBF due to POLL overflow

Description

C60081 represents number of abnormal releases of downlink signaling TBF due to POLL overflow.

Measurement Point

C60081 increments when BSC abnormally releases the downlink signaling TBF due to POLL overflow.

C60082 Definition

Number of abnormal releases of downlink signaling TBF due to N3105 overflow

Description

C60082 represents number of abnormal releases of downlink signaling TBF due to N3105 overflow.

Measurement Point

C60082 increments when BSC abnormally releases the downlink signaling TBF due to N3105 overflow.

C60083 Definition

Number of abnormal releases of downlink signaling TBF due to forced release

Description

C60083 represents number of abnormal releases of downlink signaling TBF due to forced release.

Measurement Point

C60083 increments when BSC abnormally releases the downlink signaling TBF due to forced release.

C60084 Definition

Number of abnormal releases of downlink signaling TBF due to dead suspending of the instance

Description

C60084 represents number of abnormal releases of downlink signaling TBF due to dead suspending of the instance.

Page 507: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 491

Measurement Point

C60084 increments when BSC abnormally releases the downlink signaling TBF due to dead suspending of the instance.

C60085 Definition

Number of abnormal release of downlink signaling TBF due to internal error

Description

C60085 represents number of abnormal releases of downlink signaling TBF due to internal error.

Measurement Point

C60085 increments when BSC abnormally releases the downlink signaling TBF due to internal error.

The internal error refers to abnormal release case except for those such as forced release, timer overflow, or counter overflow, etc.

C60086 Definition

Number of abnormal release of downlink GPRS data TBF due to POLL overflow

Description

C60086 represents number of abnormal release of downlink GPRS data TBF due to POLL overflow.

Measurement Point

C60086 increments when BSC abnormally releases the downlink GPRS data TBF due to POLL overflow.

C60087 Definition

Number of abnormal release of downlink GPRS data TBF due to N3105 overflow

Description

C60087 represents number of abnormal release of downlink GPRS data TBF due to N3105 overflow.

Measurement Point

C60087 increments when BSC abnormally releases the downlink GPRS data TBF due to N3105 overflow.

Page 508: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

492 Confidential and Proprietary Information of ZTE CORPORATION

C60088 Definition

Number of abnormal release of downlink GPRS data TBF due to forced release

Description

C60088 represents number of abnormal release of downlink GPRS data TBF due to forced release.

Measurement Point

C60088 increments when BSC abnormally releases the downlink GPRS data TBF due to forced release.

C60089 Definition

Number of abnormal release of downlink GPRS data TBF due to dead suspending of the instance

Description

C60089 represents number of abnormal release of downlink GPRS data TBF due to dead suspending of the instance.

Measurement Point

C60089 increments when BSC abnormally releases the downlink GPRS data TBF due to dead suspending of the instance.

C60090 Definition

Number of abnormal release of downlink GPRS data TBF due to internal error

Description

C60090 represents number of abnormal release of downlink GPRS data TBF due to internal error

Measurement Point

C60090 increments when BSC abnormally releases the downlink GPRS data TBF due to internal error.

Note: Internal error refers to abnormal release case except for those such as forced release, timer overflow or counter overflow.

C60091 Definition

Page 509: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 493

Number of abnormal release of downlink EGPRS data TBF due to POLL overflow

Description

C60091 represents number of abnormal release of downlink EGPRS data TBF due to POLL overflow.

Measurement Point

C60091 increments when BSC abnormally releases downlink EGPRS data TBF due to POLL overflow.

C60092 Definition

Number of abnormal release of downlink EGPRS data TBF due to N3105 overflow

Description

C60092 represents number of abnormal release of downlink EGPRS data TBF due to N3105 overflow

Measurement Point

C60092 increments when BSC abnormally releases the downlink EGPRS data TBF due to N3105 overflow.

C60093 Definition

Number of abnormal release of downlink EGPRS data TBF due to forced release

Description

C60093 represents number of abnormal release of downlink EGPRS data TBF due to forced release

Measurement Point

C60093 increments when BSC abnormally releases the downlink EGPRS data TBF due to forced release.

C60094 Definition

Number of abnormal release of downlink EGPRS data TBF due to dead suspending of the instance

Description

C60094 represents number of abnormal release of downlink EGPRS data TBF due to dead suspending of the instance

Page 510: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

494 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

C60094 increments when BSC abnormally releases the downlink EGPRS data TBF due to dead suspending of the instance.

C60095 Definition

Number of abnormal release of downlink EGPRS data TBF due to internal error

Description

C60095 represents number of abnormal release of downlink EGPRS data TBF due to internal error

Measurement Point

C60095 increments when BSC abnormally releases the downlink EGPRS data TBF due to internal error.

Internal error refers to abnormal release case except for those such as forced release, timer overflow or counter overflow.

Table 50 lists the counters, calculated from above mentioned counters.

T AB L E 50 C O U N T E R S C60301~ C60352

Counter Number. Description Calculation instruction Remark

C60301

Percentage of CS1 coding scheme in uplink GPRS data transmission

C60011/(C60011+C60012+C60013+ C60014)×100

two-digit-decimal precision, percentage representation

C60302

Percentage of CS2 coding scheme in uplink GPRS data transmission

C60012/(C60011+C60012+ C60013+ C60014)×100

two-digit-decimal precision, percentage representation

C60303

Percentage of CS3 coding scheme in uplink GPRS data transmission

C60013/(C60011+C60012+ C60013+ C60014)×100

two-digit-decimal precision, percentage representation

C60304

Percentage of CS4 coding scheme in uplink GPRS data transmission

C60014/(C60011+C60012+ C60013+ C60014)×100

two-digit-decimal precision, percentage representation

C60305

Percentage of MCS1 coding scheme in uplink EGPRS data transmission

C60015/(C60015+C60016+ C60017+C60018+C60019+C60020+C60021+C60022+C60023)×100

two-digit-decimal precision, percentage representation

Page 511: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 495

C60306

Percentage of MCS2 coding scheme in uplink EGPRS data transmission

C60016/(C60015+ C60016+C60017+ C60018+ C60019+C60020+ C60021+ C60022+ C60023)×100

two-digit-decimal precision, percentage representation

C60307

Percentage of MCS3 coding scheme in uplink EGPRS data transmission

C60017/( C60015+C60016+ C60017+C60018+C60019+C60020+C60021+C60022+C60023)×100

two-digit-decimal precision, percentage representation

C60308

Percentage of MCS4 coding scheme in uplink EGPRS data transmission

C60018/(C60015+C60016+ C60017+C60018+C60019+C60020+C60021+C60022+C60023)×100

two-digit-decimal precision, percentage representation

C60309

Percentage of MCS5 coding scheme in uplink EGPRS data transmission

C60019/(C60015+C60016+C60017+ C60018+C60019+C60020+C60021+C60022+ C60023)×

100

two-digit-decimal precision, percentage representation

C60310

Percentage of MCS6 coding scheme in uplink EGPRS data transmission

C60020/(C60015+C60016+C60017+ C60018+C60019+C60020+C60021+C60022+ C60023)×

100

two-digit-decimal precision, percentage representation

C60311

Percentage of MCS7 coding scheme in uplink EGPRS data transmission

C60021/(C60015+C60016+C60017+ C60018+C60019+C60020+C60021+C60022+ C60023)×

100

two-digit-decimal precision, percentage representation

C60312

Percentage of MCS8 coding scheme in uplink EGPRS data transmission

C60022/(C60015+C60016+C60017+ C60018+C60019+C60020+C60021+C60022+ C60023)×

100

two-digit-decimal precision, percentage representation

C60313

Percentage of MCS9 coding scheme in uplink EGPRS data transmission

C60023/(C60015+C60016+C60017+ C60018+C60019+C60020+C60021+C60022+ C60023)×

100

two-digit-decimal precision, percentage representation

C60314

Percentage of CS1 coding scheme in downlink GPRS data transmission

C60024/(C60024+C60025+C60026+ C60027)×100

two-digit-decimal precision, percentage representation

C60315

Percentage of CS2 coding scheme in downlink GPRS data transmission

C60025/(C60024+C60025+C60026+ C60027)×100

two-digit-decimal precision, percentage representation

C60316

Percentage of CS3 coding scheme in downlink GPRS data transmission

C60026/(C60024+C60025+C60026+ C60027)×100

two-digit-decimal precision, percentage representation

C60317

Percentage of CS4 coding scheme in downlink GPRS data transmission

C60027/(C60024+C60025+C60026+ C60027)×100

two-digit-decimal precision, percentage representation

Page 512: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

496 Confidential and Proprietary Information of ZTE CORPORATION

C60318

Percentage of MCS1 coding scheme in downlink EGPRS data transmission

C60028/(C60028+C60029+C60030+ C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60319

Percentage of MCS2 coding scheme in downlink EGPRS data transmission

C60029/(C60028+C60029+C60030+C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60320

Percentage of MCS3 coding scheme in downlink EGPRS data transmission

C60030/(C60028+C60029+C60030+ C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60321

Percentage of MCS4 coding scheme in downlink EGPRS data transmission

C60031/(C60028+C60029+C60030+C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60322

Percentage of MCS5 coding scheme in downlink EGPRS data transmission

C60032/(C60028+C60029+C60030+C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60323

Percentage of MCS6 coding scheme in downlink EGPRS data transmission

C60033/(C60028+C60029+C60030+C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60324

Percentage of MCS7 coding scheme in downlink EGPRS data transmission

C60034/(C60028+C60029+C60030+ C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60325

Percentage of MCS8 coding scheme in downlink EGPRS data transmission

C60035/(C60028+C60029+C60030+ C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60326

Percentage of MCS9 coding scheme in downlink EGPRS data transmission

C60036/(C60028+C60029+C60030+C60031+C60032+C60033+C60034+C60035+ C60036)×

100

two-digit-decimal precision, percentage representation

C60327

Percentage of CS1 coding scheme NACK block in GPRS uplink data transmission

C60037/(C60037+C60038+C60039+C60040)×100

two-digit-decimal precision, percentage representation

C60328

Percentage of CS2 coding scheme NACK block in GPRS uplink data transmission

C60038/(C60037+C60038+C60039+C60040)×100

two-digit-decimal precision, percentage representation

Page 513: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 497

C60329

Percentage of CS3 coding scheme NACK block in GPRS uplink data transmission

C60039/(C60037+C60038+C60039+ C60040)×100

two-digit-decimal precision, percentage representation

C60330

Percentage of CS4 coding scheme NACK block in GPRS uplink data transmission

C60040/(C60037+C60038+C60039+C60040)×100

two-digit-decimal precision, percentage representation

C60331

Percentage of CS1 coding scheme NACK block in GPRS downlink data transmission

C60041/(C60041+C60042+C60043+ C60044)×100

two-digit-decimal precision, percentage representation

C60332

Percentage of CS2 coding scheme NACK block in GPRS downlink data transmission

C60042/(C60041+C60042+C60043+C60044)×100

two-digit-decimal precision, percentage representation

C60333

Percentage of CS3 coding scheme NACK block in GPRS downlink data transmission

C60043/(C60041+C60042+C60043+ C60044)×100

two-digit-decimal precision, percentage representation

C60334

Percentage of CS4 coding scheme NACK block in GPRS downlink data transmission

C60044/(C60041+C60042+C60043+C60044)×100

two-digit-decimal precision, percentage representation

C60335

Percentage of MCS1 coding scheme NACK block in EGPRS uplink data transmission

C60045/(C60045+C60046+C60047+C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60336

Percentage of MCS2 coding scheme NACK block in EGPRS uplink data transmission

C60046/(C60045+C60046+C60047+C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60337

Percentage of MCS3 coding scheme NACK block in EGPRS uplink data transmission

C60047/(C60045+C60046+C60047+ C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60338

Percentage of MCS4 coding scheme NACK block in EGPRS uplink data transmission

C60048/(C60045+C60046+C60047+ C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60339

Percentage of MCS5 coding scheme NACK block in EGPRS uplink data transmission

C60049/(C60045+C60046+C60047+C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

Page 514: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

498 Confidential and Proprietary Information of ZTE CORPORATION

C60340

Percentage of MCS6 coding scheme NACK block in EGPRS uplink data transmission

C60050/(C60045+C60046+C60047+ C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60341

Percentage of MCS7 coding scheme NACK block in EGPRS uplink data transmission

C60051/(C60045+C60046+C60047+ C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60342

Percentage of MCS8 coding scheme NACK block in EGPRS uplink data transmission

C60052/(C60045+C60046+C60047+ C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60343

Percentage of MCS9 coding scheme NACK block in EGPRS uplink data transmission

C60053/(C60045+C60046+C60047+C60048+C60049+C60050+C60051+C60052+ C60053)×

100

two-digit-decimal precision, percentage representation

C60344

Percentage of MCS1 coding scheme NACK block in EGPRS downlink data transmission

C60054/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60345

Percentage of MCS2 coding scheme NACK block in EGPRS downlink data transmission

C60055/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60346

Percentage of MCS3 coding scheme NACK block in EGPRS downlink data transmission

C60056/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60347

Percentage of MCS4 coding scheme NACK block in EGPRS downlink data transmission

C60057/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60348

Percentage of MCS5 coding scheme NACK block in EGPRS downlink data transmission

C60058/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60349

Percentage of MCS6 coding scheme NACK block in EGPRS downlink data transmission

C60059/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

Page 515: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 499

C60350

Percentage of MCS7 coding scheme NACK block in EGPRS downlink data transmission

C60060/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60351

Percentage of MCS8 coding scheme NACK block in EGPRS downlink data transmission

C60061/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

C60352

Percentage of MCS9 coding scheme NACK block in EGPRS downlink data transmission

C60062/(C60054+C60055+C60056+C60057+C60058+C60059+C60060+C60061+ C60062)×

100

two-digit-decimal precision, percentage representation

Network Service Sub layer Counters NS sub layer counters takes NSVC as measurement unit. These counters provide statistics such as data transmission, signaling interaction, and abnormal link transmission of NSVC link. Table 51 lists measurement counters.

T AB L E 51 NS S U B L AY E R C O U N T E R S

Counter Number. Definition

C50001 Number of bytes sent by NS sub layer

C50002 Number of bytes received by NS sub layer

C50003 Number of PDU data sent by NS sub layer

C50004 Number of PDU data received by NS sub layer

C50005 Number of PDU data discarded by NS sub layer

C50006 Number of reset messages send to opposite end by NS sub layer

C50007 Number of received reset messages sent by opposite end

C50008 Number of reset confirm messages send to opposite end by NS sub layer

C50009 Number of received reset confirm messages sent by opposite end

C50010 Number of blocking messages send to opposite end by NS sub layer

C50011 Number of received blocking messages sent by opposite end

C50012 Number of blocking confirm messages send to opposite end by NS sub layer

C50013 Number of received blocking confirm messages sent by opposite end

C50014 Number of unblocking messages send to opposite end by NS sub layer

Page 516: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

500 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Definition

C50015 Number of received unblocking messages sent by opposite end

C50016 Number of unblocking confirm messages send to opposite end by NS sub layer

C50017 Number of received unblocking messages sent by opposite end

C50018 Number of abnormal cases in NS transmitting procedure due to network fault

C50019 Number of abnormal cases in NS transmitting procedure due to O&M interference

C50020 Number of abnormal cases in NS transmitting procedure due to equipment fault

C50021 Number of abnormal cases in NS transmitting procedure due to NSVC block

C50022 Number of abnormal cases in NS transmitting procedure due to unknown NSVC

C50023 Number of abnormal cases in NS transmitting procedure due to protocol error

C50024 Number of failed test procedure (after exceeding the maximum times)

C50025 Number of failed blocking procedure (after exceeding the maximum times)

C50026 Number of failed unblocking procedure (after exceeding the maximum times)

Network Service Sub layer Counters Explanation C50001 Definition

Number of bytes sent by NS sub layer

Description

C50001 records number of bytes sent by NS sub layer.

Measurement Point

FR accumulates number of bytes send each time.

C50002 Definition

Number of bytes received by NS sub layer

Description

Page 517: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 501

C50002 records number of bytes received by NS sub layer.

Measurement Point

FR accumulates number of bytes received from Gb interface.

C50003 Definition

Number of PDU data sent by NS sub layer

Description

C50003 records number of PDU sent by NS sub layer.

Measurement Point

FR accumulates one every time when sending a PDC to Gb.

C50004 Definition

Number of PDU data received by NS sub layer

Description

C50004 records number of PDU received by NS sub layer.

Measurement Point

FR accumulates one every time when receiving a PDC from Gb.

C50005 Definition

Number of PDU data discarded by NS sub layer

Description

C50005 records number of PDU discarded by NS sub layer.

Measurement Point

FR accumulates when discarding PDU due to congestion.

C50006 Definition

Number of reset messages sent to opposite end by NS sub layer

Description

C50006 records number of reset messages sent to opposite end by NS sub layer.

Measurement Point

Page 518: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

502 Confidential and Proprietary Information of ZTE CORPORATION

C50006 increments when NSC sending NS_RESET PDU.

C50007 Definition

Number of received reset messages sent by opposite end

Description

C50007 records number of received reset messages sent by opposite end.

Measurement Point

C50007 increments when NSC receiving NS_RESET PDU.

C50008 Definition

Number of reset confirm messages send to opposite end by NS sub layer

Description

C50008 records number of reset confirm messages sent to opposite end by NS sub layer.

Measurement Point

C50008 increments when NSC sending NS_RESETACK PDU.

C50009 Definition

Number of received reset confirm messages sent by opposite end

Description

C50009 increments records number of received reset confirm messages sent by opposite end.

Measurement Point

Definition

C50009 increments when NSC receiving NS_RESET ACK PDU.

C50010 Definition

Number of blocking messages sent to opposite end by NS sub layer

Description

Page 519: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 503

C5001 records Number of blocking messages sent to opposite end by NS sub layer.

Measurement Point

Definition

C50010 increments when NSC sending NS_BLOCK PDU.

C50011 Definition

Number of received blocking messages sent by opposite end

Description

C50011 records Number of received blocking messages sent by opposite end.

Measurement Point

C50011 increments when NSC receiving NS_BLOCK PDU.

C50012 Definition

Number of blocking confirm messages send to opposite end by NS sub layer

Description

C50012 records Number of blocking confirm messages send to opposite end by NS sub layer.

Measurement Point

C50012 increments when NSC sending NS_BLOCK ACK PDU.

C50013 Definition

Number of received blocking confirm messages sent by opposite end

Description

C50013 records Number of received blocking confirm messages sent by opposite end.

Measurement Point

C50013 increments when NSC receiving NS_BLOCK ACK PDU.

C50014 Definition

Page 520: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

504 Confidential and Proprietary Information of ZTE CORPORATION

Number of unblocking messages sent to opposite end by NS sub layer

Description

C50014 records Number of unblocking messages send to opposite end by NS sub layer.

Measurement Point

C50014 increments when NSC sending NS_UNBLOCK PDU.

C50015 Definition;

Number of received unblocking messages sent by opposite end

Description

C50015 records Number of received unblocking messages sent by opposite end.

Measurement Point

C50015 increments when NSC receiving NS_UNBLOCK PDU.

C50016 Definition

Number of unblocking confirm messages send to opposite end by NS sub layer

Description

C50016 records number of unblocking confirm messages sent to opposite end by NS sub layer.

Measurement Point

C50016 increments when NSC sending NS_UNBLOCK ACK PDU.

C50017 Definition

Number of received unblocking messages sent by opposite end

Description

C50017 records Number of received unblocking messages sent by opposite end.

Measurement Point

C50017 increments when NSC receiving NS_UNBLOCK ACK PDU.

Page 521: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 505

C50018 Definition

Number of number of abnormal cases in NS transmitting procedure due to network fault

Description

C50018 records Number of received unblocking messages sent by opposite end.

Measurement Point

C50018 increments when NSVC receiving frame trunk reporting that fault cause is transmission network fault.

C50019 Definition

Number of number of abnormal cases in NS transmitting procedure due to O&M interference

Description

C50019 records number of abnormal cases in NS transmitting procedure due to O&M interference.

Measurement Point

C50019 increments when NSVC receiving background blocking request

C50020 Definition

Number of number of abnormal cases in NS transmitting procedure due to equipment fault

Description

C50020 records number of number of abnormal cases in NS transmitting procedure due to equipment fault.

Measurement Point

C50020 increments when NSVC receiving frame trunk reporting that fault cause is transmission network fault.

C50021 Definition

Number of number of abnormal cases in NS transmitting procedure due to NSVC block

Description

Page 522: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

506 Confidential and Proprietary Information of ZTE CORPORATION

C50021 records number of number of abnormal cases in NS transmitting procedure due to NSVC block.

Measurement Point

C50021 increments when the cause of sending status message is NSVC BLOCKED

C50022 Definition

Number of number of abnormal cases in NS transmitting procedure due to unknown NSVC

Description

C50022 records number of number of abnormal cases in NS transmitting procedure due to unknown NS-VC.

Measurement Point

C50022 increments when the cause of sending status message is NSVC identification error.

C50023 Definition

Number of number of abnormal cases in NS transmitting procedure due to protocol error

Description

C50023 records number of number of abnormal cases in NS transmitting procedure due to protocol error.

Measurement Point

C50023 increments when cause of sending status message is protocol error. It includes PDU semantic error, PDU incompatible with protocol, protocol error, invalid necessary IE and missing necessary IE.

C50024 Definition

Number of failed test procedure (after exceeding the maximum times)

Description

C50024 records number of failed test procedure after exceeding the maximum times.

Measurement Point

C50024 increments when transmission time of NSVC link NS_ALIVE PDU exceeds the maximum retransmission time.

Page 523: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 507

C50025 Definition

Number of failed blocking procedure after exceeding the maximum times

Description

C50025 records number of failed blocking procedure after exceeding the maximum times.

Measurement Point

C50025 increments when transmission time of NSVC link NS_BLOCK PDU exceeds the maximum retransmission time.

C50026 Definition

Number of failed unblocking procedure after exceeding the maximum times

Description

C50026 records number of failed unblocking procedure after exceeding the maximum times.

Measurement Point

C50026 increments when transmission of NSVC link NS_UNBLOCK PDU exceeds the maximum retransmission time.

BSSGP Layer Counters Table 52 lists all BSSGP layer counters.

T AB L E 52 BSSGP L AY E R C O U N T E R S

Counter Number. Description

C51001 Number of BSC receiving PTP packet paging

C51002 Number of BSC receiving PTP circuit paging

C51003 Number of Wireless status PDU messages sent by BSC

C51004 Number of Status messages sent by BSC

C51005 Number of Status messages received by BSC

C51006 Number of Flow control messages sent by BSC

C51007 Number of Flow control ACK messages received by BSC

C51008 Total number of requests of discarding message by BSSGP layer user

Page 524: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

508 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Description

C51009 Number of Wireless status messages sent by BSC due to Losing wireless association with MS

C51010 Number of Wireless status messages sent by BSC due to Bad link quality

C51011 Number of Wireless status messages sent by BSC due to Cell reselection command

C51012 Number of Status messages sent with cause BVCI Unknown

C51013 Number of Status messages sent with cause Cell service congestion

C51014 Number of Status messages sent with cause of protocol error

C51015 Number of Status messages sent with cause Processor overload

C51016 Number of Status messages received with cause BVCI Unknown

C51017 Number of Status messages received with cause Cell service congestion

C51018 Number of Status messages received with cause of protocol error

C51019 Number of Status messages received with cause Processor overload

C51020 Number of Pause messages received by BSC

C51021 Number of Pause ACK messages returned by SGSN

C51022 Number of Pause un ACK messages returned by SGSN

C51023 Number of FLUSH-LL PDU messages received by BSC from SGSN

C51024 Number of FLUSH-LL-ACK messages sent by BSC

C51025 Number of BVC blocking messages that BSS sends

C51026 Number of BVC blocking ACK messages that BSS receives

C51027 Number of BVC unblocking messages that BSS sends

C51028 Number of BVC unblocking ACK messages that BSS receives

C51029 Number of BVC reset messages that BSS sends

C51030 Number of BVC reset messages that BSS receives

C51031 Number of BVC reset ACK messages returned by BSS

C51032 Number of BVC reset ACK messages that BSS receives

BSSGP Counters Explanation C51001 Definition

Number of reception of PTP packet paging of BSC

Description

C51001 records number of BSC receiving PTP packet paging.

Measurement Point

Page 525: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 509

C51001 increments one every time when BSC receives a PTP packet paging.

C51002 Definition

Number of reception of PTP circuit paging by BSC

Description

C51002 records number of BSC receiving PTP circuit paging.

Measurement Point

C51002 increments one every time BSC receiving a PTP circuit paging from GS interface.

C51003 Definition

Number of Wireless state PDU messages sent by BSC

Description

C51003 records number of Wireless state PDU messages sent by BSC.

Measurement Point

C51003 increments one every time BSC transmitting a Radio Status to SGSN, and the message transmits when POLLING timer overflows or T3195 timer overflows.

C51004 Definition

Number of “State” messages sent by BSC

Description

C51004 records number of State messages sent by BSC

Measurement Point

C51004 increments one every time when BSC sends BSSGP STATUS message to SGSN. PDC module returns BSSGP STAUS message to SGSN when it receives messages sent by SGSN that not satisfy receiving conditions.

C51005 Definition

Number of “State” messages received by BSC

Description

Page 526: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

510 Confidential and Proprietary Information of ZTE CORPORATION

C51005 records number of State messages received by BSC.

Measurement Point

C51005 increments one every time when BSC receives a BSSGP STAUS message sent by SGSN.

C51006 Definition

Number of Flow control messages sent by BSC

Description

C51006 records number of Flow control messages sent by BSC.

Measurement Point

C51006 increments one every time when BSC sends a BVC flow control message to SGSN.

C51007 Definition

Number of Flow control ACKNOWLDGMENT messages received by BSC

Description

C51007 records number of Flow control ACKNOWLDGMENT messages received by BSC

Measurement Point

C51007 increments one every time when BSC receives a BVC flows control ACKNOWLDGMENT message sent by SGSN that satisfy conditions.

C51008 Definition

Total number of requests of discarding message by BSSGP layer user

Description

The counter records total number of requests of discarding message by BSSGP layer user.

Measurement Point

The counter increments to one every time BSC sending LLC DISCARD message to SGSN.

C51009 Definition

Page 527: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 511

Number of Wireless state messages sent by BSC due to losing wireless association with MS message

Description

C51009 records number of Wireless state messages sent by BSC due to losing wireless association with MS message.

Measurement Point

C51009 increments when POLLLING timer overflows message.

C51010 Definition

Number of Wireless state messages sent by BSC due to Bad link quality

Description

C51010 represents number of Wireless state messages sent by BSC due to Cell service congesting message.

Measurement Point

C51010 increments when BSC sends wireless state message due to Cell service congesting message.

C51011 Definition

Number of Wireless state messages sent by BSC due to Cell reselection command message

Description

C51011 records number of Wireless state messages sent by BSC due to Cell reselection command message.

Measurement Point

C51010 increments when BSC sending wireless state message due to Cell reselection command message.

C51012 Definition

Number of State messages sent with cause Unknown BVCI message

Description

C51012 records number of State messages sent with cause Unknown BVCI message.

Measurement Point

Page 528: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

512 Confidential and Proprietary Information of ZTE CORPORATION

C51012 increments when BSC sends wireless state message due to Unknown BVCI message.

C51013 Definition

Number of State messages sent with cause Cell service congesting message

Description

C51013 records number of State messages sent with cause Cell service congesting message.

Measurement Point

C51013 increments when BSC sending STATUS message due to cell service congestion message.

C51014 Definition

Number of State messages sent with cause of protocol error

Description

C51014 records number of State messages sent with cause of protocol error message.

Measurement Point

C51014 increments when BSC receives SGSN data with coding/decoding error message.

C51015 Definition

Number of State messages sent with cause Processor overload

Description

C51015 records number of State messages sent with cause Processor overload message.

Measurement Point

The counter increments to one when BSC sends STATUS message with ‘processor overload cause’ message.

C51016 Definition

Number of State messages received with cause Unknown BVCI message

Page 529: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 513

Description

C51016 records number of State messages received with cause Unknown BVCI message.

Measurement Point

C51016 increments when BSC receives STATUS message with cause Unknown BVCI message.

C51017 Definition

Number of State messages received with cause Cell service congesting

Description

C51017 records number of State messages received with cause Cell service congesting message.

Measurement Point

C51017 increments when BSC receiving STATUS message with cell service congestion cause.

C51018 Definition

Number of State messages received with cause of protocol error

Description

C51018 records number of State messages received with cause of protocol error message.

Measurement Point

C51016 increments when BSC receives STATUS message with protocol error cause message.

C51019 Definition

Number of State messages received with cause Processor overload

Description

C51019 records number of State messages received with cause Processor overload

Measurement Point

C51019 increments when BSC receives STATUS message with processor overload cause message.

Page 530: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

514 Confidential and Proprietary Information of ZTE CORPORATION

C51020 Definition

Number of Pause messages received by BSC

Description

C51020 records number of Pause messages received by BSC

Measurement Point

C51020 increments every time BSC receives SUSPEND message from MS.

C51021 Definition

Number of “Pause Acknowledged” messages returned by SGSN

Description

C51021 records number of Pause Acknowledged messages returned by SGSN.

Measurement Point

C51021 increments every time when BSC receives a SUSPEND ACK message sent by SGSN satisfying conditions.

C51022 Definition

Number of Pause un Acknowledged messages returned by SGSN

Description

C51022 records number of Pause un Acknowledged messages returned by SGSN

Measurement Point

C51022 increments every time BSC receiving a SUSPEND NACK message sent by SGSN satisfying conditions

C51023 Definition

Number of FLUSH-LL PDU messages received by BSC from SGSN

Description

C51023 records number of FLUSH-LL PDU messages received by BSC from SGSN.

Measurement Point

Page 531: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 515

C51023 increments every time when BSC receives a FLUSH_LL PDU message sent by SGSN

C51024 Definition

Number of FLUSH-LL-Acknowledged messages sent by BSC

Description

C51024 records number of FLUSH-LL-Acknowledged messages sent by BSC.

Measurement Point

C51024 increments every time when BSC receives a FLUSH_LL_ACK message sent by SGSN.

C51025 Definition

Number of BVC blocking messages that BSS sends

Description

C51025 records number of BVC blocking messages that BSS sends.

Measurement Point

C51025 increments every time when BSC sends a BVC BLOCK message.

C51026 Definition

Number of BVC blocking ACKNOWLDGMENT messages that BSS receives

Description

C51026 records number of BVC blocking ACKNOWLDGMENT messages that BSS receives.

Measurement Point

C51026 increments every time when BSC receives BVC BLOCK ACK message sent by SGSN satisfying conditions.

C51027 Definition

Number of BVC unblocking messages that BSS sends

Page 532: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

516 Confidential and Proprietary Information of ZTE CORPORATION

Description

C51027 records number of BVC unblocking messages that BSS sends.

Measurement Point

C51027 increments every time when BSC sending BVC UNBLOCK message to SGSN.

C51028 Definition

Number of BVC unblocking ACKNOWLDGMENT messages that BSS receives

Description

C51028 records number of BVC unblocking ACKNOWLDGMENT messages that BSS receives.

Measurement Point

C51028 increments every time when BSC receives BVC UNBLCOK ACK message.

C51029 Definition

Number of BVC reset messages that BSS sends

Description

C51029 records number of BVC reset messages that BSS sends.

Measurement Point

C51029 increments every time when BSC sends BVC RESET message to SGSN.

C51030 Definition

Number of BVC reset messages that BSS receives

Description

C51030 records number of BVC reset messages that BSS receives.

Measurement Point

C51030 increments every time when BSC receiving BVC RESET message sent by SGSN.

C51031 Definition

Page 533: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 517

Number of “BVC reset ACKNOWLDGMENT” messages returned by BSS

Description

C51031 records number of BVC reset ACKNOWLDGMENT messages returned by BSS

Measurement Point

C51031 increments every time when BSC sends BVC RESET ACK message to SGSN

C51032 Definition

Number of BVC reset ACKNOWLDGMENT messages that BSS receives

Description

C51032 records number of BVC reset ACKNOWLDGMENT messages that BSS receives.

Measurement Point

C51032 increments every time when BSC receives BVC RESET ACK message sent by SGSN.

NSE Performance Counters T AB L E 53 NSE P E R F O R M AN C E C O U N T E R S

Counter Number. Definition

C52001 Number of CS Paging that BSS receives

C52002 Number of PS Paging that BSS receives

C52003 Total number of status messages sent

C52004 Total number of Status messages received

C52005 Number of Status messages sent with cause BVCI Unknown

C52006 Number of Status messages sent with cause Cell service congestion

C52007 Number of Status messages sent with cause of protocol error

C52008 Number of Status messages sent with cause Processor overload

C52009 Number of Status messages sent with cause of Semantically incorrect PDU

C52010 Number of Status messages sent with cause Invalid mandatory information element

C52011 Number of Status messages sent with cause Missing mandatory IE

C52012 Number of Status messages sent with cause Missing conditional IE

Page 534: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

518 Confidential and Proprietary Information of ZTE CORPORATION

Counter Number. Definition

C52013 Number of Status messages sent with cause Unexpected conditional IE

C52014 Number of Status messages sent with cause Conditional IE error

C52015 Number of Status messages sent with cause Conditional IE error

C52016 Number of Status messages received with cause BVCI Unknown

C52017 Number of Status messages received with cause Cell service congestion

C52018 Number of “Status” messages received with cause of protocol error

C52019 Number of Status messages received with cause Processor overload

C52020 Number of Status messages received with cause BVC blocking

C52021 Number of Status messages received with cause Semantically incorrect PDU

C52022 Number of Status messages received with cause Invalid mandatory IE

C52023 Number of Status messages received with cause Missing mandatory IE

C52024 Number of Status messages received with cause Missing conditional IE

C52025 Number of Status messages received with cause Unexpected conditional IE

C52026 Number of Status messages received with cause Conditional IE error

C52027 Number of Status messages received with cause PDU not compatible with the protocol state

C52028 Number of Status messages received with cause SGSN congestion

C52029 Number of Signaling BVC reset messages sent by Gb

C52030 Number of Signaling BVC reset ACK messages received by Gb

C52031 Number of Signaling BVC reset messages received by Gb

C52032 Number of Signaling BVC reset ACK messages sent by Gb

NSE Performance Counters Explanation C52001 Definition

Number of CS Paging that BSS receives

Description

C52001 records Number of Paging CS messages received by NSE entity on BSC.

Measurement Point

C52001 increments every time when BSC receives PSGING CS message.

Page 535: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 519

C52002 Definition

Number of PS Paging that BSS receives

Description

C52002 records number of Paging PS messages received by NSE entity on BSC.

Measurement Point

C52001 increments when BSC receives PSGING PS message.

C52003 Definition

Total number of status messages sent

Description

C52003 records total number of STATUS messages sent from NSE entity.

NSE entity send STATUS message to opposite end entity when NSE entity receives downlink BSSGP PDU and abnormal cases happens. The message indicates following abnormal cases:

BVCI unknown

cell traffic congestion

Protocol error

Processor overload

Semantically incorrect PDU

Invalid mandatory information

Missing mandatory IE

Missing conditional IE

Measurement Point

C52003 increments when NSE entity in BSC sends message with STATUS type to the opposite end entity

C52004 Definition

Total number of status messages received

Description

C52004 records total number of STATUS messages returned from SGSN.

Page 536: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

520 Confidential and Proprietary Information of ZTE CORPORATION

When BSSGP PDU send to SGSN is abnormal, NSE receives STATUS message returned from the opposite end. The message indicates the following abnormal cases:

BVCI unknown

cell traffic congestion

Protocol error

Processor overload

Semantically incorrect PDU

Invalid mandatory information

Missing mandatory IE

Missing conditional IE

Measurement Point

C52005 get increments when NSE receives STATUS message.

C52005 Number of “Status” messages sent with cause “BVCI Unknown”

Description

C52005 records number of STATUS messages sent to opposite end entity from NSE, with cause “BVCI Unknown”.

Measurement Point

C52005 increments when NSE sends STATUS message to opposite end entity with cause BVCI Unknown.

C52006 Definition

Number of “Status” messages sent due to cell service congestion

Description

Number of STATUS messages sent due to cell service congestion sent to opposite end entity from NSE

Measurement Point

C52006 increments when NSE sending STATUS message to opposite end entity with cause Cell traffic congestion

C52007 Definition

Number of Status messages sent with cause of protocol error

Page 537: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 521

Description

C52007 number of STATUS messages sent to opposite end entity from NSE with cause of Protocol error.

Measurement Point

C52007 increments when NSE sends STATUS message to opposite end entity with cause Protocol error.

C52008 Definition

Number of Status messages sent with cause “Processor overload”

Description

C52008 records number of STATUS messages sent, with cause Protocol error sent to opposite end entity from NSE.

Measurement Point

C52008 increments when NSE sending STATUS message to opposite end entity with cause “Protocol error”

C52009 Definition

Numbers of “Status” messages sent with cause of “Semantically incorrect PDU”

Description

Number of STATUS messages sent with cause “Semantically incorrect PDU” send to opposite end entity from NSE

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “Semantically incorrect PDU”

C52010 Definition

Number of “Status” messages sent with cause “Invalid mandatory information element”

Description

Number of STATUS messages sent to opposite end entity from NSE with cause “Invalid mandatory information”

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “Invalid mandatory information”

Page 538: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

522 Confidential and Proprietary Information of ZTE CORPORATION

C52011 Definition

Number of “Status” messages sent with cause “Missing mandatory IE”

Description

Number of STATUS messages sent to opposite end entity from NSE with cause “Missing mandatory IE”

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “Missing mandatory IE”

C52012 Definition

Number of “Status” messages sent with cause “Missing conditional IE”

Description

Number of STATUS messages sent with cause “Missing conditional IE” to the opposite end entity from NSE

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “Missing conditional IE”

C52013 Definition

Number of “Status” messages sent with cause “Unexpected conditional IE”

Description

Number of STATUS messages sent with cause “Unexpected conditional IE” to opposite end entity from NSE

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “Unexpected conditional IE”

C52014 Definition

Number of “Status” messages sent with cause “Conditional IE error”

Description

Number of STATUS messages sent with cause “Conditional IE error” to opposite end entity from NSE

Page 539: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 523

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “Conditional IE error”

C52015 Definition

Number of “Status” messages sent with cause “PDU not compatible with the protocol state”

Description

Number of STATUS messages sent with cause “PDU not compatible with the protocol state” to the opposite end entity from NSE

Measurement Point

The counter increments to one when NSE sending STATUS message to opposite end entity with cause “PDU not compatible with the protocol state”

C52016 Definition

Number of “Status” messages received with cause “BVCI Unknown”

Description

The measurement value records number of STATUS messages received with cause “BVCI Unknown”

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “BVCI Unknown”

C52017 Definition

Number of “Status” messages received with cause “Cell service congestion”

Description

Number of STATUS messages received by PCU with cause “Cell traffic congestion” from SGSN

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Cell traffic congestion”

Page 540: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

524 Confidential and Proprietary Information of ZTE CORPORATION

C52018 Definition

Number of “Status” messages received with cause of protocol error

Description

The measurement value records number of received STATUS messages with cause “Protocol error”

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Protocol error”

C52019 Definition

Number of “Status” messages received with cause “Processor overload”

Description

Number of STATUS messages received by PCU with cause “Processor overload” from SGSN.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Processor overload”

C52020 Definition

Number of “Status” messages received with cause “BVC blocking”

Description

Number of STATUS messages received by PCU with cause “BVCI-blocked” from SGSN.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “BVCI-blocked”

C52021

Definition

Number of “Status” messages received with cause “Semantically incorrect PDU”

Description

Page 541: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 525

The measurement value records number of received STATUS messages with cause “Semantically incorrect PDU”.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Semantically incorrect PDU”

C52022 Definition

Number of “Status” messages received with cause “Invalid mandatory IE”

Description

The measurement value records number of received STATUS messages with cause “Invalid mandatory IE”.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Invalid mandatory IE”

C52023 Definition

Number of “Status” messages received with cause “Missing mandatory IE”

Definition

The measurement value records number of received STATUS messages with cause “Missing mandatory IE”.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Missing mandatory IE”

C52024 Definition

Number of “Status” messages received with cause “Missing conditional IE”

Definition

The measurement value records number of received STATUS messages with cause “Missing conditional IE”.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Missing conditional IE”

Page 542: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

526 Confidential and Proprietary Information of ZTE CORPORATION

C52025 Definition

Number of “Status” messages received with cause “Unexpected conditional IE”

Description

The measurement value records number of received STATUS messages with cause “Unexpected conditional IE”

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Unexpected conditional IE”

C52026 Definition

Number of “Status” messages received with cause “Conditional IE error”

Description

The measurement value records number of received STATUS messages with cause “Conditional IE error”

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “Conditional IE error”

C52027 Definition

Number of “Status” messages received with cause “PDU not compatible with the protocol state”

Description

The measurement value records number of received STATUS messages with cause “PDU not compatible with the protocol state”.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “PDU not compatible with the protocol state”

C52028 Definition

Number of “Status” messages received with cause “SGSN congestion”

Description

Page 543: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 527

The measurement value records number of received STATUS messages with cause “SGSN congestion”.

Measurement Point

The counter increments to one when PCU receiving STATUS message with cause “SGSN congestion”

C52029 Definition

Number of “Signaling BVC reset” messages sent by Gb

Description

Number of PCU sending signaling BVC reset through Gb.

Measurement Point

The counter increments when the NSE entity on BSC sending message with BVC-RESET type and BVCI is zero

C52030

Definition

Number of “Signaling BVC reset ACK” messages received by Gb

Description

Number of “Signaling BVC reset ACK” messages received by PCU

Measurement Point

The counter increments when the NSE entity on BSC receiving message with BVC-RESET-ACK type and BVCI is zero

C52031 Definition

Number of “Signaling BVC reset” messages received by Gb

Description

Number of “Signaling BVC reset” messages received by PCU.

Measurement Point

The counter increments when the NSE entity on BSC receiving message with BVC-RESET type and BVCI is zero

C52032 Definition

Number of “Signaling BVC reset ACK” messages sent by Gb

Description

Page 544: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

528 Confidential and Proprietary Information of ZTE CORPORATION

After receiving “Signaling BVC reset” messages from Gb interface, PCU will return “Signaling BVC reset ACK” messages.

Measurement Point

The counter increments when the NSE entity on BSC sending message with BVC-RESET-ACK type and BVCI is zero

Resource Management Counters Table 54 represents Counters for Resource Management.

T AB L E 54 R E S O U R C E M AN A G E M E N T C O U N T E R S

Counter Number. Definition

C61001 Number of forced retracting dynamic PDCH by BSC

C61002 Number of successfully activating dynamic PDCH

C61003 Number of failed activating dynamic PDCH

C61004 Number of PDCH failure recovery

C61005 Number of PDCH failure recovery

C61006 Number of cell attempting uplink assignment due to ONE PHASE access

C61007 Number of cell successful uplink assignment due to ONE PHASE access

C61008 Number of cell attempts for uplink assignment due to single block packet access

C61009 Number of cell successful uplink assignment due to single block packet access

C61010 Number of cell attempt uplink assignment due to response paging

C61011 Number of cell successful uplink assignment due to response paging

C61012 Number of cell attempts for uplink assignment due to cell updating

C61013 Number of cell successful uplink assignment due to cell updating

C61014 Number of cell attempts for uplink assignment due to mobility management

C61015 Number of cell successful uplink assignment due to mobility management

C61016 Number of cell attempts for uplink assignment due to TWO PHASE access

C61017 Number of cell successful uplink assignment due to TWO PHASE access

C61018 Number of cell attempts for uplink assignment due to short access

C61019 Number of cell successful uplink assignment due to short access

C61020 Number of messages in PGH-AGCH queue

C61021 Number of assignment messages in PPCH-PAGCH queue

C61022 Number of paging messages deleted from PCH queue

C61023 Number of packet paging messages deleted from PPCH queue

Page 545: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 529

Counter Number. Definition

C61024 Number of paging messages send unsuccessfully from cell

C61025 Average Number of available PDCH

C61026 Maximum Number of available PDCH

C61027 Minimum Number of available PDCH

C61028 Average Number of occupied PDCH

C61029 Maximum Number of occupied PDCH

C61030 Minimum Number of occupied PDCH

C61031 Average number of messages in PCH-AGCH queue

C61032 Average number of messages in PPCH-PAGCH queue

Resource Management Counters Explanation C61001 Definition

Number of forced retracting dynamic PDCH by BSC

Description

The counter indicates number of dynamic PDCH converting into TCH

Measurement Point

The counter increments when dynamic channel forcibly converts from PS state to CS state.

C61002 Definition

Number of successfully activating dynamic PDCH

Description

The counter indicates number of dynamic channel successfully converting from TCH to PDCH

Measurement Point

The counter increments when the flow of dynamic channel converts from TCH to PDCH succeeds

C61003 Definition

Page 546: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

530 Confidential and Proprietary Information of ZTE CORPORATION

Number of failed activating dynamic PDCH

Description

The counter indicates failure number of dynamic channel converting from TCH to PDCH

Measurement Point

When dynamic channel fails to converts from TCH to PDCH, The counter increments to accumulate

C61004 Definition

Number of PDCH failure recovery

Description

The counter indicates number of PDCH failure

Measurement Point

The counter increments when PDCH blocks due to blocking cause

C61005 Definition

Number of PDCH failure recovery

Description

The counter indicates number of PDCH failure blocking recovery

Measurement Point

The counter increments when PDCH is unblocked due to blocking recovery

C61006 Definition

Number of cell attempting uplink assignment due to ONE PHASE access

Description

The counter records number of correct channel requests after receiving the access because that is ONE PHASE access

Measurement Point

After receiving channel request, BSC checks whether the cell, the channel requests and the access cause are correct. C61006 accumulates, if access cause is ONE PHASE access and channel request is correct.

Page 547: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 531

C61007 Definition

Number of cell successful uplink assignment due to ONE PHASE access

Description

The counter records number of successful assignments after receiving ONE PHASE access cause

Measurement Point

When the cell configures PCCCH in the case of ONE PHASE access, The counter increments after BSC database successfully assigns related resource. When the cell does not configure PCCCH in the case of ONE PHASE access, the counter increments after BSC sends instant assignment. It then receives message returned by BTS, which is also send to MS.

C61008 Definition

Number of cell attempts for uplink assignment due to single block packet access

Description

The counter records number of correct channel requests after receiving Single Block access cause.

Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the access cause are correct. C61008 accumulates for correct channel request and access cause is single block access.

C61009 Definition

Number of cell successful uplink assignment due to single block packet access

Description

The counter records number of successful assignment after receiving Single Block access cause

Measurement Point

When the cell configures PCCCH in the case of single block access, The counter increments after BSC database successfully assigning related resource

Page 548: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

532 Confidential and Proprietary Information of ZTE CORPORATION

C61010 Definition

Number of cell attempts for uplink assignment due to response paging

Description

The counter records number of correct channel requests after receiving the access cause, which is response paging.

Measurement Point

Definition

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the access cause are correct. C61010 accumulates for correct channel request and the access cause is response paging.

C61011 Definition

Number of cell successful uplink assignment due to response paging

Description

The counter records number of successful assignment after receiving the access cause, which is response paging

Measurement Point

When the cell configures PCCCH in the case of response paging, The counter increments after BSC database successfully assigning related resource

C61012 Number of cell attempts for uplink assignment due to cell updating

Description

The counter records number of correct channel requests after receiving the access cause, which is cell updating

Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the access cause are correct. C61012 accumulates for correct channel request and the access cause is cell updating.

C61013 Definition

Number of cell successful uplink assignment due to cell updating

Page 549: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 533

Description

The counter records number of successful assignment after receiving the access cause, which is cell updating

Measurement Point

When the cell configures PCCCH in the case of cell updating, the counter increments after BSC database successfully assigning related resource

C61014 Definition

Number of cell attempts for uplink assignment due to mobility management

Description

The counter records number of correct channel requests after receiving the access cause, which is mobility management

Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the access cause are correct. C61014 accumulates for correct channel request and the access cause is mobility management.

C61015 Number of cell successful uplink assignment due to mobility management

Description

The counter records number of successful assignment after receiving the access cause, which is mobility management

Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the mobility management are correct. C61015 accumulates for correct channel request and the access cause is mobility management.

C61016 Definition

Number of cell attempts for uplink assignment due to TWO PHASE access

Description

The counter records number of correct channel requests after receiving the access cause, which is TWO PHASE access.

Page 550: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

534 Confidential and Proprietary Information of ZTE CORPORATION

Measurement Point

After receiving channel request, BSC checks whether the cell the channel requests and the access cause are correct. C61016 accumulates for correct channel request and the access cause is TWO PHASE access.

C61017 Definition

Number of cell successful uplink assignment due to TWO PHASE access

Description

The counter records number of successful assignment after receiving the access cause, which is TWO PHASE access.

Measurement Point

When the cell configures PCCCH in the case of TWO PHASE access, The counter increments after BSC database successfully assigning related resource; when the cell doesn’t configure PCCCH in the case of TWO PHASE access, The counter increments after BSC sends instant assignment and receives message returned by BTS which is also send to MS.

C61018 Definition

Number of cell attempts for uplink assignment due to short access

Description

The counter records number of correct channel requests after receiving the access cause, which is short access.

Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the access cause are correct. C61018 accumulates for correct channel request and the access cause is short access.

C61019 Definition

Number of cell successful uplink assignments due to short access

Description

The counter records number of successful assignments after receiving the access cause, which is short access.

Measurement Point

Page 551: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 535

When the cell configures PCCCH, after receiving channel request, BSC checks whether the cell the channel requests and the short access are correct. C61019 accumulates for correct channel request and the access cause is short access.

C61020 Definition

Number of messages in PGH-AGCH queue

Description

The counter records number of the assignment messages waiting in a queue and will be send on PCH-AGCH.

Measurement Point

Not calculated for the time being

C61021 Definition

Number of assignment messages in PPCH-PAGCH queue

Description

The counter records number of assignment messages waiting in a queue and will be send on PPCH-PAGCH.

Measurement Point

Not calculated for the time being

C61022 Definition

Number of paging messages deleted from PCH queue

Description

The counter records number of paging messages deleted from PCH queue

Measurement Point

Not calculated for the time being

C61023 Definition

Number of packet paging messages deleted from PPCH queue

Description

Page 552: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

536 Confidential and Proprietary Information of ZTE CORPORATION

The counter records number of packet paging messages deleted from PPCH queue

Measurement Point

Not calculated for the time being

C61024 Definition

Number of paging messages sent unsuccessfully from cell

Description

The counter records number of paging messages send unsuccessfully from cell

Measurement Point

Not calculated for the time being

C61025 Definition

Average number of available PDCH

Description

The counter records average Number of available PDCH

Measurement Point

Querying the database every thirty seconds to obtain the number of configured PDCH of the cell.

Sum of available PDCHs within five minutes/number of statistics = Average number of available PDCH

C61025 increments at the time of measurement cycle, every five minutes.

C61026 Definition

Maximum number of available PDCH

Description

The counter records maximum number of available PDCH.

Measurement Point

C61026 increments at the time of measurement cycle, every five minutes.

Page 553: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Chapter 30 - Packet Switched Service Measurement

Confidential and Proprietary Information of ZTE CORPORATION 537

C61027 Definition

Minimum number of available PDCH

Description

The counter records minimum number of available PDCHs.

Measurement Point

C61027 increments at the time of measurement cycle, every five minutes.

C61028 Definition

Average number of occupied PDCH

Description

The counter records average number of assigned PDCHs.

Measurement Point

C61028 increments at the time of measurement cycle, every five minutes.

C61029 Definition

Maximum number of occupied PDCH

Description

The counter records maximum number of assigned PDCH.

Measurement Point

C61029 increments at the time of measurement cycle, every five minutes.

C61030 Definition

Minimum number of occupied PDCH

Description

The counter records minimum number of assigned PDCH.

Measurement Point

C61030 increments at the time of measurement cycle, every five minutes.

Page 554: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

538 Confidential and Proprietary Information of ZTE CORPORATION

C61031 Definition

Average number of messages in PCH-AGCH queue

Description

The counter records average number of messages waiting in a queue and will be send on PCH-AGCH.

Measurement Point

Not calculated for the time being

C61032 Definition

Average number of messages in PPCH-PAGCH queue

Description

The counter records average number of messages waiting in a queue and will be send on PPCH-PAGCH.

Measurement Point

Not calculated for the time being.

Page 555: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 539

A p p e n d i x A

Abbreviations

Abbreviation Full Name

A

Abis A-bis Interface

AIPP A Interface Peripheral Processor

AIU A Interface Unit

AUC Access Unit Controller

B

BAF BSS Adapter Function

BCCH Broadcast Channel

BIE Base station Interface Equipment

BIPP aBis Interface Peripheral Processor

BIU aBis Interface Unit

BOSN Bit Oriented Switching Network

BRP BSSGP RLC/MAC Protocol

BSIA Base Station Interface Adapter

BSC Base Station Controller

BSS Base station Sub System

BSSAP Base station Sub System Application Part

BSSGP Base station Sub System GPRS Protocol

BTS Base Transceiver Station

BVC BSSGP Virtual Connect

C

CBCH Cell Broadcast Channel

CCCH Common Control Channel

CDF Commands Dispatching Function

CLF Commands Logging Function

CMIP Common Management Information Protocol

CMIS Common Management Information Service

Page 556: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter).doc

540 Confidential and Proprietary Information of ZTE CORPORATION

Abbreviation Full Name

CRF Commands Resolution Function

CS Circuit Switched

D

DRT Dual-Rate Transcoder

DSP Digital Signal Processor

E

EDRT Enhanced DRT

EFD Event Forwarding Discriminator

EGSM Extend GSM

ESU Executable Software Unit

F

FN Frame Number

FR Frame Relay

FRP FR Protocol

FTAM File Transfer Access Maintenance

FU Frame Unit

FUC Frame Unit Controller

G

GGSN Gateway GPRS Support Node

GIPP Gb Interface Peripheral Processor

GIU GPRS Interface Unit

GPRS General Packet Radio Service

GSM Globe System for Mobile communication

GSN GPRS Support Node

H

HMS ZXIP10-AS HMS

HSN Hopping Sequence Number

L

LAF Local Access Function

LAPD Link Access Protocol of D-Channel

LMF Local Management Function

LMT Local Management Terminal

M

MAC Medium Access Control

MAF Management Application Functions

MAIO Mobile Allocation Index Offset

MIB Management Information Base

Page 557: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix A - Abbreviations

Confidential and Proprietary Information of ZTE CORPORATION 541

Abbreviation Full Name

MIT MO Instance Tree

MF Mediation Function

MKF MMI Kernel Function

MMI Man Machine Interface

MML Man Machine Language

MO Managed Object

MOC Managed Object Class

MOF MO administration Function

MP Main Processor

MS Mobile Station

MSC Mobile Switch Center

MSF Management Support Function

MTP Message Transfer Part

N

NAF NMC Access Function

NC Network Control

NEF Network Element Function

NMC Network Management Center

NS Network Service

NSVC NS Virtual Circuit

O

OMC Operation Maintenance Center

OMCR Operation Maintenance Center Radio

OOF Operation Outputting Function

OSF Operations Systems Function

P

PACCH Packet Associated Control Channel

PAGCH Paging & Access Granted Channel

PCU Packet Control Unit

PDCH Packet Data Channel

PDTCH Packet Data Traffic Channel

PDU Protocol Data Unit

PP Peripheral Processor

PS Packet Switched

PTM Point To Multipoint

PTP Point To Point

PUC Packet Unit Control

Page 558: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter).doc

542 Confidential and Proprietary Information of ZTE CORPORATION

Abbreviation Full Name

PVC Permanent Virtual Circuit

R

RACH Random Access Channel

RMM Radio Management Module

RLC Radio Link Control

S

SDCCH Specified Control Channel

SGSN Serving GPRS Support Node

SMB Short Message Broadcast

SMM Service Management Module

SMS Short Message Service

SSF Session Services Function

T

TC TransCoder

TCH Traffic Channel

TCPP TransCoder unit Peripheral Processor

TIC Trunk Interface Circuit

TMM Transport Management Module

TMN Telecommunication Management Network

TRAU Transcoder and Rate Adaptor Unit

TRX Transceiver

U

UISF User Interface Support Function

W

WAF Windows Administration Function

WSF WorkStation Function

Page 559: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 543

A p p e n d i x B

Tables

Table 1 chapters summary ...........................................................................xi Table 2 Typographical Conventions.............................................................. xiii Table 3 Mouse Operation Conventions.......................................................... xiv Table 4 Safety Signs...................................................................................xv Table 5 key performance indicators ............................................................... 1 Table 6 power control counters ....................................................................42 Table 7 trx service counters.........................................................................52 Table 8 Paging Measurement Counters ..........................................................75 Table 9 Counters of Carrier Frequency-Level Basic Measurement.......................75 Table 10 TRX power and Temperature counters ..............................................76 Table 11 channel measurement counters.......................................................79 Table 12 random access counters .................................................................92 Table 13 sdcch counters............................................................................104 Table 14 sapi 3 Counters...........................................................................146 Table 15 rmm assignment counters ............................................................155 Table 16 rmm assignment queue counter ....................................................162 Table 17 rmm call drop counters ................................................................163 Table 18 Handover Cause Counters ............................................................183 Table 19 handover counters ......................................................................202 Table 20 synchronized handover counters....................................................251 Table 21 paging message counter...............................................................256 Table 22 abis-interface message counters....................................................258 Table 23 resourse availability counters ........................................................271 Table 24 - sub cell counters......................................................................282 Table 25 bssap message counters ..............................................................301 Table 26 bssmap message counters............................................................304 Table 27 smm assignment Counters ...........................................................309 Table 28 SMM Handover Counters ..............................................................312 Table 29 smm call drop counters ................................................................315 Table 30 SCCP Connection Counters ...........................................................319 Table 31 Trunk Circuit Counters .................................................................322 Table 32 lapd link counters........................................................................326 Table 33 rmm load counters ......................................................................333 Table 34 service load counter ....................................................................336 Table 35 usability measurement counter .....................................................337 Table 36 smm load counters ......................................................................338 Table 37 file system load counters..............................................................338 Table 38 Q3 module measurement counters ................................................341 Table 39 Q3 cell measurement counters ......................................................352 Table 40 adjacent cell handover counters ....................................................355 Table 41 phase-3 nms counters .................................................................364 Table 42 tch/h measurement counters ........................................................381 Table 43 hr measurement counters.............................................................409 Table 44 Counters for Reserved Channels ....................................................435

Page 560: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter).doc

544 Confidential and Proprietary Information of ZTE CORPORATION

Table 45 PS Basic Measurement Counters – Cell as the Unit ...........................439 Table 46 Counters for PS Basic Measurement – BSC as Unit ...........................445 Table 47 Correspondence Relationships between Bandwidth and Coding Scheme

......................................................................................................459 Table 48 Counters C70501~C70536 ...........................................................482 Table 49 Traffic Statistic Counters ..............................................................486 Table 50 Counters C60301~ C60352...........................................................518 Table 51 NS Sub layer Counters .................................................................523 Table 52 BSSGP Layer Counters .................................................................532 Table 53 NSE Performance Counters ...........................................................543 Table 54 Resource Management counters ....................................................554

Page 561: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 547

A p p e n d i x C

Figures

FIGURE 1 - power control process ...............................................................42 FIGURE 2 - intra cell handover process..........................................................55 FIGURE 3 - intra bsc handover process..........................................................56 FIGURE 4 - inter-cell handover failure process................................................59 FIGURE 5 - intra cell handover failure process ................................................60 FIGURE 6 - T8 Timeout ...............................................................................63 FIGURE 7 - random access process...............................................................94 FIGURE 8 - sdcch assignment flow..............................................................103 FIGURE 9 - immediate assignment flow.......................................................115 FIGURE 10 - common assignment flow........................................................115 FIGURE 11 - internal handover (intra-bsc handover) .....................................116 FIGURE 12 - external handover (intra-msc handover)....................................116 FIGURE 13 - sapi 3 Counters measurement points ........................................146 FIGURE 14 - Intra-BSC Inter-cell Handover Measurement ..............................209 FIGURE 15 - intra msc handover successes..................................................210 FIGURE 16 - intra msc handover fail ...........................................................210 FIGURE 17 - Intra MSC Handover in............................................................214 FIGURE 18 - external handover in process (Part Flow) ...................................265 FIGURE 19 - calculating sdcch busy time .....................................................275 FIGURE 20 - smm assignment process ........................................................309 FIGURE 21 - assignment failures Process.....................................................311 FIGURE 22 - handover process...................................................................312 FIGURE 23 - Handover Failure Process ........................................................314 FIGURE 24 - SCCP Connection Setup ..........................................................318 FIGURE 25 - Time Delay Scenario in SCCP Connection Setup..........................320 FIGURE 26 - SCCP ‘Connection Refused’ from MSC........................................321 FIGURE 27 - Total Busy Time for the Trunk Circuits.......................................324 FIGURE 28 - successful intra cell handover process .......................................344 FIGURE 29 - intra-cells handover filure process ............................................345 FIGURE 30 - successful inter-cell handover process.......................................345 FIGURE 31 - inter-cell handover failure process ............................................349 FIGURE 32 - immidiate assignment flow ......................................................379 FIGURE 33 - common assignment flow........................................................379 FIGURE 34 - internal handover (intra-bsc handover) .....................................380 FIGURE 35 - external handover (intra-msc handover)....................................380 FIGURE 36 - CONVERSIONS from tch/f to tch/h............................................430 FIGURE 37 - Calculating Time of Stale Uplink GPRS TBF Receiving Window.......471 FIGURE 38 - Calculating Time of Stale Downlink GPRS TBF Transmitting Window

......................................................................................................473

Page 562: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

548 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 563: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Confidential and Proprietary Information of ZTE CORPORATION 549

A p p e n d i x D

Index

C00001 ............................... 44, 45 C00002 ............................... 44, 46 C00003 ............................... 44, 46 C00004 ............................... 44, 46 C00005 ............................... 44, 47 C00006 ............................... 44, 47 C00007 ............................... 44, 47 C00008 ............................... 44, 47 C00009 ............................... 44, 48 C00010 ............................... 44, 48 C00011 ............................... 44, 48 C00012 ............................... 45, 49 C00013 ............................... 45, 49 C00014 ............................... 45, 49 C00015 ............................... 45, 49 C00016 ............................... 45, 50 C00017 ............................... 45, 50 C00018 ............................... 45, 50 C00019 ............................... 45, 51 C00020 ............................... 45, 51 C00021 ............................... 45, 51 C00022 ............................... 45, 51 C00023 ............................... 45, 52 C00024 ............................... 45, 52 C00025 ............................... 45, 52 C00026 ............................... 45, 53 C00027 ............................... 45, 53 C00028 ............................... 45, 53 C00029 ............................... 54, 57 C00030 ............................... 54, 58 C00031 ............................... 54, 58 C00032 ............................... 54, 59 C00033 ............................... 54, 59 C00034 ............................... 54, 59 C00035 ............................... 54, 59 C00036 ............................... 54, 60 C00037 ............................... 54, 60 C00038 ............................... 54, 60 C00039 ............................... 54, 61 C00040 ............................... 54, 62 C00041 ............................... 54, 62 C00042 ............................... 55, 63 C00043 ............................... 55, 63 C00044 ............................... 55, 63 C00045 ............................... 55, 63 C00046 ............................... 55, 64 C00047 ............................... 55, 64

C00048 ............................... 55, 64 C00049 ............................... 55, 65 C00050 ............................... 55, 65 C00051 ............................... 55, 66 C00052 ............................... 55, 66 C00053 ............................... 55, 66 C00054 ............................... 55, 67 C00055 ............................... 55, 67 C00056 ............................... 55, 67 C00057 ............................... 55, 67 C00058 ............................... 55, 68 C00059 ............................... 55, 68 C00060 ............................... 55, 68 C00061 ............................... 55, 68 C00062 ............................... 55, 69 C00063 ............................... 55, 69 C00064 ............................... 56, 69 C00065 ............................... 56, 69 C00066 ............................... 56, 70 C00067 ............................... 56, 70 C00068 ............................... 56, 70 C00069 ............................... 56, 70 C00070 ............................... 56, 71 C00071 ............................... 56, 71 C00072 ............................... 56, 71 C00073 ............................... 56, 72 C00074 ............................... 56, 72 C00075 ............................... 56, 72 C00076 ............................... 56, 72 C00077 ............................... 56, 73 C00078 ............................... 56, 73 C00079 ............................... 56, 73 C00080 ............................... 56, 73 C00081 ............................... 56, 74 C00082 ............................... 56, 74 C00083 ............................... 56, 74 C00084 ............................... 56, 74 C00085 ............................... 56, 75 C00086 ............................... 56, 75 C00087 ............................... 57, 75 C00088 ............................... 57, 75 C00089 ............................... 57, 76 C00090 ............................... 57, 76 C00091 ............................... 57, 76 C00092 ............................... 57, 76 C01001 .....................................77 C01002 .....................................77

Page 564: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

550 Confidential and Proprietary Information of ZTE CORPORATION

C01003 .....................................77 C01004 .....................................77 C02001 ...................................354 C02002 ...................................354 C02003 ...................................354 C02004 ...................................354 C02005 ...................................354 C02006 ...................................354 C02007 ...................................354 C02008 ...................................355 C02009 ...................................355 C02010 ...................................355 C02011 ...................................355 C02012 ...................................355 C02013 ...................................355 C02014 ...................................355 C10001 ............................... 94, 96 C10002 ............................... 94, 96 C10003 ............................... 95, 97 C10004 ............................... 95, 97 C10005 ............................... 95, 97 C10006 ............................... 95, 98 C10007 ............................... 95, 98 C10008 ............................... 95, 98 C10009 ............................... 95, 98 C10010 ............................... 95, 99 C10011 ............................... 95, 99 C10012 ............................... 95, 99 C10013 ............................. 95, 100 C10014 ............................. 95, 100 C10015 ............................. 95, 100 C10016 ............................. 95, 101 C10017 ............................. 95, 101 C10018 ............................. 95, 101 C10019 ............................. 95, 102 C10020 ............................. 95, 102 C10021 ............................. 95, 102 C10022 ............................. 95, 102 C10023 ............................. 95, 103 C10024 ............................. 95, 103 C10025 ............................. 96, 103 C10101 ...................................106 C10102 ............................106, 108 C10103 ............................106, 108 C10104 ............................106, 108 C10105 ............................106, 109 C10106 ............................106, 109 C10107 ............................106, 110 C10108 ............................106, 110 C10109 ............................106, 110 C10110 ............................106, 111 C10111 ............................106, 111 C10112 ............................106, 111 C10113 ............................106, 112 C10114 ............................106, 112 C10115 ............................106, 112 C10116 ............................106, 113 C10117 ............................106, 113 C10118 ............................106, 113 C10119 ............................106, 114 C10201 ............................148, 149

C10202 ............................148, 150 C10203 ............................148, 150 C10204 ............................148, 150 C10205 ............................148, 150 C10206 ............................148, 151 C10207 ............................149, 151 C10208 ............................149, 151 C10209 ............................149, 152 C10210 ............................149, 152 C10211 ............................149, 152 C10212 ............................149, 152 C10213 ............................149, 153 C10214 ............................149, 153 C10215 ............................149, 153 C10216 ............................149, 153 C10217 ............................149, 153 C10218 ............................149, 154 C10219 ............................149, 154 C10220 ............................149, 154 C10221 ............................149, 154 C10222 ............................149, 154 C10223 ............................149, 155 C10224 ............................149, 155 C10225 ............................149, 155 C10301 ............................119, 122 C10302 ............................119, 122 C10303 ............................119, 122 C10304 ............................119, 123 C10305 ............................119, 123 C10306 ............................119, 123 C10307 ............................119, 124 C10308 ............................119, 124 C10309 ............................119, 124 C10310 ............................119, 125 C10311 ............................119, 125 C10312 ............................119, 125 C10313 ............................119, 126 C10314 ............................119, 126 C10315 ............................119, 126 C10316 ............................119, 127 C10317 ............................119, 127 C10318 ............................119, 127 C10319 ............................119, 128 C10320 ............................119, 128 C10321 ............................119, 128 C10322 ............................120, 129 C10323 ............................120, 129 C10324 ............................120, 129 C10325 ............................120, 130 C10326 ............................120, 130 C10327 ............................120, 130 C10328 ............................120, 131 C10329 ............................120, 131 C10330 ............................120, 132 C10331 ............................120, 132 C10332 ............................120, 132 C10333 ............................120, 133 C10334 ............................120, 133 C10335 ............................120, 133 C10336 ............................120, 134 C10337 ............................120, 134

Page 565: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix D - Index

Confidential and Proprietary Information of ZTE CORPORATION 551

C10338 ............................120, 134 C10339 ............................120, 135 C10340 ............................120, 135 C10341 ............................120, 136 C10342 ............................120, 136 C10343 ............................120, 136 C10344 ............................120, 137 C10345 ............................120, 137 C10346 ............................121, 137 C10347 ............................121, 138 C10348 ............................121, 138 C10349 ............................121, 138 C10350 ............................121, 139 C10351 ............................121, 139 C10352 ............................121, 139 C10353 ............................121, 140 C10354 ............................121, 140 C10355 ............................121, 140 C10356 ............................121, 141 C10357 ............................121, 141 C10358 ............................121, 141 C10359 ............................121, 142 C10360 ............................121, 142 C10361 ............................121, 142 C10362 ............................121, 143 C10363 ............................121, 143 C10364 ............................121, 143 C10365 ............................121, 144 C10366 ............................121, 144 C10367 ............................121, 144 C10368 ............................121, 145 C10369 ............................122, 145 C10401 ............................383, 386 C10402 ............................383, 386 C10403 ............................383, 386 C10404 ............................383, 387 C10405 ............................383, 387 C10406 ............................383, 387 C10407 ............................383, 388 C10408 ............................383, 388 C10409 ............................383, 388 C10410 ............................383, 389 C10411 ............................383, 389 C10412 ............................383, 389 C10413 ............................383, 390 C10414 ............................383, 390 C10415 ............................383, 390 C10416 ............................383, 390 C10417 ............................383, 391 C10418 ............................383, 391 C10419 ............................383, 392 C10420 ............................383, 392 C10421 ............................383, 392 C10422 ............................384, 392 C10423 ............................384, 393 C10424 ............................384, 393 C10425 .....................384, 393, 421 C10426 ............................384, 394 C10427 ............................384, 394 C10428 ............................384, 394 C10429 ............................384, 395

C10430 ............................384, 395 C10431 ............................384, 396 C10432 ............................384, 396 C10433 ............................384, 396 C10434 ............................384, 397 C10435 ............................384, 397 C10436 ............................384, 397 C10437 ............................384, 398 C10438 ............................384, 398 C10439 ............................384, 399 C10440 ............................384, 399 C10441 ............................384, 399 C10442 ............................384, 400 C10443 ............................384, 400 C10444 ............................384, 400 C10445 ............................385, 401 C10446 ............................385, 401 C10447 ............................385, 401 C10448 ............................385, 402 C10449 ............................385, 402 C10450 ............................385, 403 C10451 ............................385, 403 C10452 ............................385, 403 C10453 ............................385, 403 C10454 ............................385, 404 C10455 ............................385, 404 C10456 ............................385, 404 C10457 ............................385, 405 C10458 ............................385, 405 C10459 ............................385, 405 C10460 ............................385, 406 C10461 ............................385, 406 C10462 ............................385, 406 C10463 ............................385, 407 C10464 ............................385, 407 C10465 ............................385, 407 C10466 ............................385, 408 C10467 ............................385, 408 C10468 ............................385, 408 C10469 ............................386, 409 C10470 ...................................435 C10471 ............................435, 436 C10472 ............................435, 436 C10473 ............................435, 436 C10501 ............................157, 158 C10502 ............................157, 158 C10503 ............................157, 159 C10504 ............................157, 159 C10505 ............................157, 159 C10506 ............................157, 160 C10507 ............................158, 160 C10508 ............................158, 160 C10509 ............................158, 160 C10510 ............................158, 161 C10511 ............................158, 161 C10512 ............................158, 161 C10513 ............................158, 162 C10514 ............................158, 162 C10515 ............................158, 162 C10516 ............................158, 163 C10517 ............................158, 163

Page 566: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

552 Confidential and Proprietary Information of ZTE CORPORATION

C10518 ............................158, 163 C10601 ............................165, 168 C10602 ............................165, 168 C10603 ............................165, 168 C10604 ............................165, 169 C10605 ............................165, 169 C10606 ............................165, 169 C10607 ............................166, 170 C10608 ............................166, 170 C10609 ............................166, 170 C10610 ............................166, 171 C10611 ............................166, 171 C10612 ............................166, 171 C10613 ............................166, 171 C10614 ............................166, 172 C10615 ............................166, 172 C10616 ............................166, 172 C10617 ............................166, 173 C10618 ............................166, 173 C10619 ............................166, 173 C10620 ............................166, 174 C10621 ............................166, 174 C10622 ............................166, 175 C10623 ............................166, 175 C10624 ............................166, 175 C10625 ............................166, 175 C10626 ............................166, 176 C10627 ............................166, 176 C10628 ............................166, 177 C10629 ............................166, 177 C10630 ............................167, 177 C10631 ............................167, 177 C10632 ............................167, 178 C10633 ............................167, 178 C10634 ............................167, 178 C10635 ............................167, 179 C10636 ............................167, 179 C10637 ............................167, 179 C10638 ............................167, 180 C10639 ............................167, 180 C10640 ............................167, 180 C10641 ............................167, 181 C10642 ............................167, 181 C10643 ............................167, 181 C10644 ............................167, 182 C10645 ............................167, 182 C10646 ............................167, 183 C10647 ............................167, 183 C10648 ............................167, 183 C10649 ............................167, 183 C10650 ............................167, 184 C10651 ............................167, 184 C10652 ............................167, 184 C10701 ............................... 81, 84 C10702 ............................... 81, 84 C10703 ............................... 81, 84 C10704 ............................... 81, 85 C10705 ............................... 82, 85 C10706 ............................... 82, 85 C10707 ............................... 82, 85 C10708 ............................... 82, 86

C10709 ............................... 82, 86 C10710 ............................... 82, 86 C10711 ............................... 82, 87 C10712 ............................... 82, 87 C10713 ............................... 82, 87 C10714 ............................... 82, 88 C10715 ............................... 82, 88 C10716 ............................... 82, 88 C10717 ............................... 82, 88 C10718 ............................... 82, 89 C10719 ............................... 82, 89 C10720 ............................... 82, 89 C10721 ............................... 82, 89 C10722 ............................... 82, 89 C10723 ............................... 82, 89 C10724 ............................... 82, 89 C10725 ............................... 82, 89 C10726 ............................... 82, 90 C10727 ............................... 82, 90 C10728 ............................... 83, 90 C10729 ............................... 83, 90 C10730 ..........................83, 90, 91 C10731 ............................... 83, 91 C10732 ............................... 83, 91 C10733 .....................................83 C10734 ............................... 83, 91 C10735 ............................... 83, 91 C10736 ............................... 83, 91 C10737 ............................... 83, 91 C10738 ............................... 83, 91 C10739 ............................... 83, 92 C10740 ............................... 83, 92 C10741 ............................... 83, 92 C10742 ............................... 83, 92 C10743 ............................... 83, 92 C10744 ............................... 83, 92 C10745 ............................... 83, 92 C10746 ............................... 83, 92 C10747 ............................... 83, 92 C10748 ............................... 83, 93 C10749 ............................... 83, 93 C10750 ............................... 83, 93 C10751 ............................... 84, 93 C10801 ............................185, 187 C10802 ............................185, 188 C10803 ............................185, 188 C10804 ............................185, 188 C10805 ............................185, 189 C10806 ............................185, 189 C10807 ............................185, 189 C10808 ............................186, 190 C10809 ............................186, 190 C10810 ............................186, 190 C10811 ............................186, 191 C10812 ............................186, 191 C10813 ............................186, 191 C10814 ............................186, 192 C10815 ............................186, 192 C10816 ............................186, 192 C10817 ............................186, 193 C10818 ............................186, 193

Page 567: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix D - Index

Confidential and Proprietary Information of ZTE CORPORATION 553

C10819 ............................186, 193 C10820 ............................186, 194 C10821 ............................186, 194 C10822 ............................186, 195 C10823 ............................186, 195 C10824 ............................186, 195 C10825 ............................186, 196 C10826 ............................186, 196 C10827 ............................186, 196 C10828 ............................186, 197 C10829 ............................186, 197 C10830 ............................187, 197 C10831 ............................187, 198 C10832 ............................187, 198 C10833 ............................187, 198 C10834 ............................187, 199 C10835 ............................187, 199 C10836 ............................187, 199 C10837 ............................187, 200 C10838 ............................187, 200 C10839 ............................187, 200 C10840 ............................187, 201 C10841 ............................187, 201 C10842 ............................187, 201 C10843 ............................187, 202 C10844 ............................187, 202 C10845 ............................187, 202 C10846 ............................187, 202 C10901 ............................204, 210 C10902 ............................204, 211 C10903 ............................204, 211 C10904 ............................204, 212 C10905 ............................204, 213 C10906 ............................204, 213 C10907 ............................205, 213 C10908 ............................205, 214 C10909 ............................205, 214 C10910 ............................205, 214 C109100...........................209, 243 C109101...........................209, 243 C109102...........................209, 243 C109103...........................209, 244 C109104...........................209, 244 C109105...........................209, 244 C109106...........................209, 244 C109107...........................209, 245 C109108...........................209, 245 C109109...........................209, 245 C10911 ............................205, 215 C109110...........................209, 245 C109111...........................209, 246 C109112...........................209, 246 C109113...........................209, 246 C109114...........................209, 247 C109115...........................209, 247 C109116...........................209, 247 C109117...........................209, 247 C109118...........................209, 248 C109119...........................209, 248 C10912 ............................205, 215 C109120...........................209, 248

C109121...........................209, 249 C109122...........................210, 249 C109123...........................210, 249 C109124...........................210, 249 C109125...........................210, 250 C109126...........................210, 250 C109127...........................210, 251 C109128...........................210, 251 C109129...........................210, 251 C10913 ............................205, 216 C10914 ............................205, 216 C10915 ............................205, 217 C10916 ............................205, 217 C10917 ............................205, 217 C10918 ............................205, 217 C10919 ............................205, 218 C10920 ............................205, 218 C10921 ............................205, 218 C10922 ............................205, 219 C10923 ............................205, 219 C10924 ............................205, 219 C10925 ............................205, 219 C10926 ............................205, 220 C10927 ............................205, 220 C10928 ............................205, 220 C10929 ............................205, 221 C10930 ............................206, 221 C10931 ............................206, 221 C10932 ............................206, 221 C10933 ............................206, 222 C10934 ............................206, 222 C10935 ............................206, 222 C10936 ............................206, 223 C10937 ............................206, 223 C10938 ............................206, 223 C10939 ............................206, 224 C10940 ............................206, 224 C10941 ............................206, 224 C10942 ............................206, 225 C10943 ............................206, 225 C10944 ............................206, 225 C10945 ............................206, 226 C10946 ............................206, 226 C10947 ............................206, 226 C10948 ............................206, 226 C10949 ............................206, 227 C10950 ............................206, 227 C10951 ............................206, 227 C10952 ............................206, 228 C10953 ............................207, 228 C10954 ............................207, 228 C10955 ............................207, 229 C10956 ............................207, 229 C10957 ............................207, 229 C10958 ............................207, 230 C10959 ............................207, 230 C10960 ............................207, 230 C10961 ............................207, 231 C10962 ............................207, 231 C10963 ............................207, 231 C10964 ............................207, 232

Page 568: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

554 Confidential and Proprietary Information of ZTE CORPORATION

C10965 ............................207, 232 C10966 ............................207, 232 C10967 ............................207, 233 C10968 ............................207, 233 C10969 ............................207, 233 C10970 ............................207, 234 C10971 ............................207, 234 C10972 ............................207, 234 C10973 ............................207, 235 C10974 ............................207, 235 C10975 ............................207, 235 C10976 ............................208, 236 C10977 ............................208, 236 C10978 ............................208, 236 C10979 ............................208, 237 C10980 ............................208, 237 C10981 ............................208, 237 C10982 ............................208, 238 C10983 ............................208, 238 C10984 ............................208, 238 C10985 ............................208, 238 C10986 ............................208, 239 C10987 ............................208, 239 C10988 ............................208, 239 C10989 ............................208, 240 C10990 ............................208, 240 C10991 ............................208, 240 C10992 ............................208, 241 C10993 ............................208, 241 C10994 ............................208, 241 C10995 ............................208, 241 C10996 ............................208, 242 C10997 ............................208, 242 C10998 ............................208, 242 C10999 ............................209, 242 C11001 ...................................164 C11002 ...................................164 C11003 ...................................164 C11004 ...................................164 C11005 ...................................164 C11101 ............................357, 358 C11102 ............................357, 358 C11103 ............................357, 359 C11104 ............................357, 359 C11105 ............................357, 359 C11106 ............................357, 360 C11107 ............................357, 360 C11108 ............................357, 361 C11109 ............................357, 361 C11110 ............................357, 361 C11111 ............................357, 362 C11112 ............................358, 362 C11113 ............................358, 363 C11114 ............................358, 363 C11115 ............................358, 363 C11116 ...................................364 C11201 ............................253, 255 C11202 ............................253, 255 C11203 ............................253, 255 C11204 ............................253, 256 C11205 ............................253, 256

C11206 ............................253, 256 C11207 ............................253, 257 C11208 ............................253, 257 C11301 ...................................258 C11401 ............................260, 262 C11402 ............................260, 262 C11403 ............................260, 262 C11404 ............................260, 262 C11405 ............................260, 263 C11406 ............................260, 263 C11407 ............................260, 263 C11408 ............................260, 264 C11409 ............................261, 264 C11410 ............................261, 264 C11411 ............................261, 265 C11412 ............................261, 265 C11413 ............................261, 265 C11414 ............................261, 265 C11415 ............................261, 266 C11416 ............................261, 266 C11417 ............................261, 266 C11418 ............................261, 267 C11419 ............................261, 267 C11420 ............................261, 268 C11421 ............................261, 269 C11422 ............................261, 269 C11423 ............................261, 269 C11424 ............................261, 270 C11425 ............................261, 270 C11426 ............................261, 270 C11427 ............................261, 270 C11428 ............................261, 271 C11429 ............................261, 271 C11430 ............................261, 271 C11431 ............................261, 272 C11501 ............................273, 274 C11502 ............................273, 275 C11503 ............................274, 275 C11504 ............................274, 275 C11505 ............................274, 277 C11506 ............................274, 277 C11507 ............................274, 278 C11508 ............................274, 278 C11509 ............................274, 278 C11510 ............................274, 279 C11511 ............................274, 279 C11512 ............................274, 280 C11513 ............................274, 280 C11514 ............................274, 280 C11515 ............................274, 281 C11516 ............................274, 281 C11517 ............................274, 282 C11518 ............................274, 282 C11519 ............................274, 283 C11520 ............................274, 283 C11521 ............................274, 283 C11601 ...................................1, 7 C11602 ...................................1, 7 C11603 ...................................1, 8 C11604 ...................................1, 8 C11605 ...................................1, 8

Page 569: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix D - Index

Confidential and Proprietary Information of ZTE CORPORATION 555

C11606 ...................................2, 9 C11607 ...................................2, 9 C11608 ...................................2, 9 C11609 .................................2, 10 C11610 .................................2, 10 C116100................................6, 36 C116101................................6, 36 C116102................................6, 36 C116103................................6, 37 C116104................................6, 37 C116105................................6, 37 C116106................................6, 37 C116107................................6, 38 C116108................................6, 38 C116109................................6, 38 C11611 .................................2, 10 C116110................................6, 38 C116111................................6, 39 C116112................................6, 39 C116113................................6, 39 C116114................................6, 39 C116115..................................... 6 C116116..................................... 6 C116117..................................... 6 C116118..................................... 6 C116119..................................... 6 C11612 .................................2, 11 C116120..................................... 7 C116121..................................... 7 C116122..................................... 7 C116123..................................... 7 C116124..................................... 7 C116125..................................... 7 C116126..................................... 7 C116127..................................... 7 C116128..................................... 7 C116129..................................... 7 C11613 .................................2, 11 C116130................................7, 40 C116131................................7, 40 C11614 .................................2, 11 C11615 .................................2, 12 C11616 .................................2, 12 C11617 .................................2, 12 C11618 .................................2, 13 C11619 .................................2, 13 C11620 .................................2, 14 C11621 .................................2, 14 C11622 .................................2, 14 C11623 .................................2, 14 C11624 .................................2, 15 C11625 .................................2, 15 C11626 .................................2, 15 C11627 .................................2, 16 C11628 .................................3, 16 C11629 .................................3, 16 C11630 .................................3, 16 C11631 .................................3, 17 C11632 .................................3, 17 C11633 .................................3, 17 C11634 .................................3, 17

C11635 .................................3, 18 C11636 .................................3, 18 C11637 .................................3, 18 C11638 .................................3, 18 C11639 .................................3, 19 C11640 .................................3, 19 C11641 .................................3, 19 C11642 .................................3, 19 C11643 .................................3, 20 C11644 .................................3, 20 C11645 .................................3, 20 C11646 .................................3, 20 C11647 .................................3, 21 C11648 .................................3, 21 C11649 .................................3, 21 C11650 .................................3, 21 C11651 .................................4, 22 C11652 .................................4, 22 C11653 .................................4, 22 C11654 .................................4, 23 C11655 .................................4, 23 C11656 .................................4, 23 C11657 .................................4, 24 C11658 .................................4, 24 C11659 .................................4, 24 C11660 .................................4, 25 C11661 .................................4, 25 C11662 .................................4, 25 C11663 .................................4, 26 C11664 .................................4, 26 C11665 .................................4, 26 C11666 .................................4, 26 C11667 .................................4, 27 C11668 .................................4, 27 C11669 .................................4, 27 C11670 .................................4, 28 C11671 .................................4, 28 C11672 .................................4, 28 C11673 .................................4, 29 C11674 .................................5, 29 C11675 .................................5, 29 C11676 .................................5, 29 C11677 .................................5, 30 C11678 .................................5, 30 C11679 .................................5, 30 C11680 .................................5, 30 C11681 .................................5, 31 C11682 .................................5, 31 C11683 .................................5, 31 C11684 .................................5, 31 C11685 .................................5, 32 C11686 .................................5, 32 C11687 .................................5, 32 C11688 .................................5, 32 C11689 .................................5, 33 C11690 .................................5, 33 C11691 .................................5, 33 C11692 .................................5, 34 C11693 .................................5, 34 C11694 .................................5, 34 C11695 .................................5, 34

Page 570: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

556 Confidential and Proprietary Information of ZTE CORPORATION

C11696 .................................5, 35 C11697 .................................6, 35 C11698 .................................6, 35 C11699 .................................6, 36 C11715 ............................368, 378 C11801 ............................343, 344 C11802 ............................343, 344 C11803 ............................343, 346 C11804 ............................343, 346 C11805 ............................343, 347 C11806 ............................343, 348 C11807 ............................343, 348 C11808 ............................343, 348 C11809 ............................344, 349 C11810 ............................344, 349 C11811 ............................344, 349 C11812 ............................344, 350 C11813 ...................................350 C11814 ............................344, 350 C11815 ............................344, 351 C11816 ............................344, 351 C11817 ............................344, 352 C11818 ............................344, 352 C11819 ............................344, 352 C11901 ............................411, 415 C11902 ............................411, 415 C11903 ............................411, 415 C11904 ............................411, 415 C11905 ............................411, 416 C11906 ............................411, 416 C11907 ............................411, 416 C11908 ............................411, 417 C11909 ............................411, 417 C11910 ............................411, 417 C11911 ............................412, 417 C11912 ............................412, 418 C11913 ............................412, 418 C11914 ............................412, 418 C11915 ............................412, 418 C11916 ............................412, 419 C11917 ............................412, 419 C11918 ............................412, 419 C11919 ............................412, 419 C11920 ............................412, 420 C11921 ............................412, 420 C11922 ............................412, 420 C11923 ............................412, 420 C11924 ............................412, 421 C11925 ...................................412 C11926 ............................412, 421 C11927 ............................412, 421 C11928 ............................412, 422 C11929 ............................412, 422 C11930 ............................412, 422 C11931 ............................412, 422 C11932 ............................412, 423 C11933 ............................412, 423 C11934 ............................413, 423 C11935 ............................413, 423 C11936 ............................413, 424 C11937 ............................413, 424

C11938 ............................413, 424 C11939 ............................413, 424 C11940 ............................413, 425 C11941 ............................413, 425 C11942 ............................413, 425 C11943 ............................413, 425 C11944 ............................413, 426 C11945 ............................413, 426 C11946 ............................413, 426 C11947 ............................413, 426 C11948 ............................413, 427 C11949 ............................413, 427 C11950 ............................413, 427 C11951 ............................413, 427 C11952 ............................413, 428 C11953 ............................413, 428 C11954 ............................413, 428 C11955 ...................................413 C11956 ............................413, 429 C11957 ............................413, 429 C11958 ............................414, 429 C11959 ............................414, 430 C11960 ...................................430 C11961 ............................414, 430 C11962 ............................414, 430 C11963 ............................414, 431 C11964 ............................414, 431 C11965 ............................414, 431 C11966 ............................414, 431 C11967 ............................414, 432 C11968 ............................414, 432 C11969 ............................414, 433 C11970 ............................414, 433 C11971 ............................414, 433 C11972 ............................414, 433 C11973 ............................414, 434 C12001 ............................284, 286 C12002 ............................284, 287 C12003 ............................284, 288 C12004 ............................284, 288 C12005 ............................284, 288 C12006 ............................284, 288 C12007 ............................284, 289 C12008 ............................284, 289 C12009 ............................285, 289 C12010 ............................285, 290 C12011 ............................285, 290 C12012 ............................285, 290 C12013 ............................285, 291 C12014 ............................285, 291 C12015 ............................285, 291 C12016 ............................285, 292 C12017 ............................285, 292 C12018 ............................285, 292 C12019 ............................285, 293 C12020 ............................285, 293 C12021 ............................285, 293 C12022 ............................285, 294 C12023 ............................285, 294 C12024 ............................285, 294 C12025 ............................285, 295

Page 571: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix D - Index

Confidential and Proprietary Information of ZTE CORPORATION 557

C12026 ............................285, 295 C12027 ............................285, 296 C12028 ............................285, 296 C12029 ............................285, 297 C12030 ............................285, 297 C12031 ............................285, 297 C12032 ............................286, 298 C12033 ............................286, 298 C12034 ............................286, 298 C12035 ............................286, 299 C12036 ............................286, 299 C12037 ............................286, 299 C12038 ............................286, 299 C12039 ............................286, 300 C12040 ............................286, 300 C12041 ............................286, 300 C12042 ............................286, 301 C12043 ............................286, 301 C12044 ............................286, 301 C12045 ............................286, 302 C12046 ............................286, 302 C13001 .....................................77 C13002 .....................................77 C13003 .....................................77 C13004 .....................................77 C14001 .....................................78 C14002 .....................................78 C14003 ............................... 78, 79 C14004 ............................... 78, 79 C14005 ............................... 78, 79 C14006 ............................... 78, 79 C20001 ...................................306 C20002 ...................................306 C20003 ...................................306 C20004 ...................................306 C20005 ...................................306 C20006 ...................................306 C20007 ...................................306 C20008 ...................................306 C20009 ...................................306 C20010 ...................................306 C20011 ...................................306 C20012 ...................................306 C20013 ...................................306 C20014 ...................................306 C20015 ...................................306 C20016 ...................................306 C20017 ...................................306 C20018 ...................................306 C20019 ...................................307 C20020 ...................................307 C20021 ...................................307 C20022 ...................................307 C20023 ...................................307 C20024 ...................................307 C20025 ...................................307 C20026 ...................................307 C20027 ...................................307 C20028 ...................................307 C20029 ...................................307 C20030 ...................................307

C20031 ...................................307 C20032 ...................................307 C20033 ...................................307 C20034 ...................................307 C20035 ...................................307 C20036 ...................................307 C20037 ...................................307 C20038 ...................................307 C20039 ...................................307 C20040 ...................................307 C20041 ...................................308 C20042 ...................................308 C20043 ...................................308 C20044 ...................................308 C20045 ...................................308 C20046 ...................................308 C20047 ...................................308 C20048 ...................................308 C20049 ...................................308 C20050 ...................................308 C20051 ...................................308 C20052 ...................................308 C20053 ...................................308 C20054 ...................................308 C20065 ...................................308 C20066 ...................................308 C20101 ............................303, 304 C20102 ............................303, 304 C20103 ............................303, 304 C20104 ............................304, 305 C20105 ............................304, 305 C20201 ...................................321 C20202 ...................................321 C20203 ............................321, 322 C20204 ............................321, 322 C20205 ............................321, 323 C20206 ............................321, 323 C20301 ...................................311 C20302 ...................................311 C20303 ............................311, 312 C20304 ............................311, 312 C20305 ............................311, 313 C20401 ...................................314 C20402 ...................................315 C20403 ...................................315 C20404 ...................................315 C20405 ...................................316 C20501 ...................................317 C20502 ...................................317 C20503 ............................317, 318 C20504 ............................317, 318 C20601 ...................................324 C20602 ............................324, 325 C20603 ............................324, 325 C20604 ............................324, 325 C20605 ............................324, 326 C30001 ............................328, 330 C30002 ............................328, 330 C30003 ............................328, 330 C30004 ............................328, 331 C30005 ............................328, 331

Page 572: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

558 Confidential and Proprietary Information of ZTE CORPORATION

C30006 ............................328, 331 C30007 ............................328, 332 C30008 ............................328, 332 C30009 ............................330, 332 C30010 ............................330, 332 C30011 ............................330, 333 C30012 ............................330, 333 C30013 ............................330, 333 C50001 ............................524, 526 C50002 ............................524, 526 C50003 ............................524, 526 C50004 ............................525, 526 C50005 ............................525, 527 C50006 ............................525, 527 C50007 ............................525, 527 C50008 ............................525, 527 C50009 ............................525, 528 C50010 ............................525, 528 C50011 ............................525, 528 C50012 ............................525, 529 C50013 ............................525, 529 C50014 ............................525, 529 C50015 ............................525, 529 C50016 ............................525, 530 C50017 ............................525, 530 C50018 ............................525, 530 C50019 ............................525, 530 C50020 ............................525, 531 C50021 ............................525, 531 C50022 ............................525, 531 C50023 ............................525, 532 C50024 ............................525, 532 C50025 ............................525, 532 C50026 ............................526, 532 C51001 ............................533, 535 C51002 ............................533, 535 C51003 ............................533, 536 C51004 ............................533, 536 C51005 ............................533, 536 C51006 ............................533, 536 C51007 ............................533, 537 C51008 ............................533, 537 C51009 ............................533, 537 C51010 ............................533, 537 C51011 ............................534, 538 C51012 ............................534, 538 C51013 ............................534, 538 C51014 ............................534, 539 C51015 ............................534, 539 C51016 ............................534, 539 C51017 ............................534, 539 C51018 ............................534, 540 C51019 ............................534, 540 C51020 ............................534, 540 C51021 ............................534, 540 C51022 ............................534, 541 C51023 ............................534, 541 C51024 ............................534, 541 C51025 ............................534, 542 C51026 ............................534, 542 C51027 ............................535, 542

C51028 ............................535, 542 C51029 ............................535, 543 C51030 ............................535, 543 C51031 ............................535, 543 C51032 ............................535, 543 C52001 ............................544, 545 C52002 ............................544, 546 C52003 ............................544, 546 C52004 ............................544, 546 C52005 ............................544, 547 C52006 ............................544, 547 C52007 ............................544, 548 C52008 ............................544, 548 C52009 ............................544, 548 C52010 ............................544, 548 C52011 ............................544, 549 C52012 ............................544, 549 C52013 ............................544, 549 C52014 ............................544, 550 C52015 ............................544, 550 C52016 ............................545, 550 C52017 ............................545, 550 C52018 ............................545, 551 C52019 ............................545, 551 C52020 ............................545, 551 C52021 ...................................545 C52022 ............................545, 552 C52023 ............................545, 552 C52024 ............................545, 552 C52025 ............................545, 553 C52026 ............................545, 553 C52027 ............................545, 553 C52028 ............................545, 554 C52029 ............................545, 554 C52030 ...................................545 C52031 ............................545, 554 C52032 ............................545, 555 C60001 ............................486, 490 C60002 ............................486, 491 C60003 ............................486, 491 C60004 ............................486, 491 C60005 ............................486, 492 C60006 ............................487, 492 C60007 ............................487, 492 C60008 ............................487, 492 C60009 ............................487, 493 C60010 ............................487, 493 C60011 ............................487, 493 C60012 ............................487, 493 C60013 ............................487, 494 C60014 ............................487, 494 C60015 ............................487, 494 C60016 ............................487, 495 C60017 ............................487, 495 C60018 ............................487, 495 C60019 ............................487, 495 C60020 ............................487, 496 C60021 ............................487, 496 C60022 ............................487, 496 C60023 ............................487, 496 C60024 ............................487, 497

Page 573: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix D - Index

Confidential and Proprietary Information of ZTE CORPORATION 559

C60025 ............................487, 497 C60026 ............................487, 497 C60027 ............................487, 498 C60028 ............................487, 498 C60029 ............................488, 498 C60030 ............................488, 498 C60031 ............................488, 499 C60032 ............................488, 499 C60033 ............................488, 499 C60034 ............................488, 499 C60035 ............................488, 500 C60036 ............................488, 500 C60037 ............................488, 500 C60038 ............................488, 501 C60039 ............................488, 501 C60040 ............................488, 501 C60041 ............................488, 502 C60042 ............................488, 502 C60043 ............................488, 502 C60044 ............................488, 502 C60045 ............................488, 503 C60046 ............................488, 503 C60047 ............................488, 503 C60048 ............................488, 504 C60049 ............................488, 504 C60050 ............................488, 504 C60051 ............................488, 505 C60052 ............................489, 505 C60053 ............................489, 505 C60054 ............................489, 506 C60055 ............................489, 506 C60056 ............................489, 506 C60057 ............................489, 507 C60058 ............................489, 507 C60059 ............................489, 507 C60060 ............................489, 507 C60061 ............................489, 508 C60062 ............................489, 508 C60063 ............................489, 508 C60064 ............................489, 508 C60065 ............................489, 509 C60066 ............................489, 509 C60067 ............................489, 509 C60068 ............................489, 510 C60069 ............................489, 510 C60070 ............................489, 510 C60071 ............................489, 510 C60072 ............................489, 511 C60073 ............................489, 511 C60074 ............................489, 511 C60075 ............................489, 512 C60076 ............................490, 512 C60077 ............................490, 512 C60078 ............................490, 513 C60079 ............................490, 513 C60080 ............................490, 513 C60081 ............................490, 513 C60082 ............................490, 514 C60083 ............................490, 514 C60084 ............................490, 514 C60085 ............................490, 515

C60086 ............................490, 515 C60087 ............................490, 515 C60088 ............................490, 516 C60089 ............................490, 516 C60090 ............................490, 516 C60091 ............................490, 516 C60092 ............................490, 517 C60093 ............................490, 517 C60094 ............................490, 517 C60095 ............................490, 518 C60301 ...................................518 C60302 ...................................518 C60303 ...................................518 C60304 ...................................518 C60305 ...................................518 C60306 ...................................519 C60307 ...................................519 C60308 ...................................519 C60309 ...................................519 C60310 ...................................519 C60311 ...................................519 C60312 ...................................519 C60313 ...................................519 C60314 ...................................519 C60315 ...................................520 C60316 ...................................520 C60317 ...................................520 C60318 ...................................520 C60319 ...................................520 C60320 ...................................520 C60321 ...................................520 C60322 ...................................520 C60323 ...................................520 C60324 ...................................521 C60325 ...................................521 C60326 ...................................521 C60327 ...................................521 C60328 ...................................521 C60329 ...................................521 C60330 ...................................521 C60331 ...................................521 C60332 ...................................521 C60333 ...................................522 C60334 ...................................522 C60335 ...................................522 C60336 ...................................522 C60337 ...................................522 C60338 ...................................522 C60339 ...................................522 C60340 ...................................522 C60341 ...................................523 C60342 ...................................523 C60343 ...................................523 C60344 ...................................523 C60345 ...................................523 C60346 ...................................523 C60347 ...................................523 C60348 ...................................523 C60349 ...................................524 C60350 ...................................524 C60351 ...................................524

Page 574: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

560 Confidential and Proprietary Information of ZTE CORPORATION

C60352 ...................................524 C61001 ............................555, 557 C61002 ............................555, 557 C61003 ............................555, 557 C61004 ............................555, 557 C61005 ............................555, 558 C61006 ............................555, 558 C61007 ............................555, 558 C61008 ............................555, 559 C61009 ............................555, 559 C61010 ............................555, 559 C61011 ............................555, 560 C61012 ............................555, 560 C61013 ............................556, 560 C61014 ............................556, 560 C61015 ............................556, 561 C61016 ............................556, 561 C61017 ............................556, 561 C61018 ............................556, 562 C61019 ............................556, 562 C61020 ............................556, 562 C61021 ............................556, 563 C61022 ............................556, 563 C61023 ............................556, 563 C61024 ............................556, 563 C61025 ............................556, 564 C61026 ............................556, 564 C61027 ............................556, 564 C61028 ............................556, 564 C61029 ............................556, 565 C61030 ............................556, 565 C61031 ............................556, 565 C61032 ............................556, 565 C70001 ............................439, 445 C70002 ............................439, 446 C70003 ............................440, 446 C70004 ............................440, 446 C70005 ............................440, 446 C70006 ............................440, 447 C70007 ............................440, 447 C70008 ............................440, 447 C70009 ............................440, 448 C70010 .....................440, 448, 450 C70011 ............................440, 448 C70012 ............................440, 448 C70013 ............................440, 449 C70014 ............................440, 449 C70015 ............................440, 449 C70016 ............................440, 449 C70017 ............................440, 450 C70018 ............................440, 450 C70019 ...................................440 C70020 ............................440, 450 C70021 ............................440, 451 C70022 ............................440, 451 C70023 ............................440, 451 C70024 ............................440, 451 C70025 ............................440, 452 C70026 ............................441, 452 C70027 ............................441, 452 C70028 ............................441, 453

C70029 ............................441, 453 C70030 ............................441, 453 C70031 ............................441, 453 C70032 ............................441, 454 C70033 ............................441, 454 C70034 ............................441, 454 C70035 ............................441, 454 C70036 ............................441, 455 C70037 ............................441, 455 C70038 ............................441, 455 C70039 ............................441, 456 C70040 ............................441, 456 C70041 ............................441, 456 C70042 ............................441, 456 C70043 ............................441, 457 C70044 ............................441, 457 C70045 ............................441, 457 C70046 ............................441, 458 C70047 ............................441, 458 C70048 ............................442, 458 C70049 ............................442, 459 C70050 ............................442, 459 C70051 ............................442, 459 C70052 ............................442, 460 C70053 ............................442, 460 C70054 ............................442, 460 C70055 ............................442, 461 C70056 ............................442, 461 C70057 ............................442, 461 C70058 ............................442, 461 C70059 ............................442, 462 C70060 ............................442, 462 C70061 ............................442, 462 C70062 ............................442, 463 C70063 ............................442, 463 C70064 ............................442, 463 C70065 ............................442, 464 C70066 ............................442, 464 C70067 ............................442, 464 C70068 ............................442, 464 C70069 ............................442, 465 C70070 ............................442, 465 C70071 ............................443, 465 C70072 ............................443, 465 C70073 ............................443, 466 C70074 ............................443, 466 C70075 ............................443, 466 C70076 ............................443, 467 C70077 ............................443, 467 C70078 ............................443, 467 C70079 ............................443, 468 C70080 ............................443, 468 C70081 ............................443, 468 C70082 ............................443, 468 C70083 ............................443, 469 C70084 ............................443, 469 C70085 ............................443, 469 C70086 ............................443, 470 C70087 ............................443, 470 C70088 ............................443, 470 C70089 ............................443, 471

Page 575: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

Appendix D - Index

Confidential and Proprietary Information of ZTE CORPORATION 561

C70090 ............................443, 471 C70091 ............................443, 472 C70092 ............................443, 473 C70093 ............................444, 473 C70094 ............................444, 474 C70095 ............................444, 474 C70096 ............................444, 474 C70097 ............................444, 475 C70098 ............................444, 475 C70099 ............................444, 475 C70100 ............................444, 476 C70101 ............................444, 476 C70102 ............................444, 476 C70103 ............................444, 476 C70104 ............................444, 477 C70105 ............................444, 477 C70106 ............................444, 477 C70107 ............................444, 478 C70108 ............................444, 478 C70109 ............................444, 478 C70110 ............................444, 478 C70111 ............................444, 479 C70112 ............................444, 479 C70113 ............................444, 479 C70114 ............................444, 479 C70115 ............................444, 480 C70116 ............................445, 480 C70117 ............................445, 480 C70118 ............................445, 480 C70119 ............................445, 481 C70120 ............................445, 481 C70121 ............................445, 481 C70501 ...................................482 C70502 ...................................482 C70503 ...................................482 C70504 ...................................482 C70505 ...................................482 C70506 ...................................482 C70507 ...................................482 C70508 ...................................482 C70509 ...................................482 C70510 ...................................482 C70511 ...................................482 C70512 ...................................482 C70513 ...................................483 C70514 ...................................483 C70515 ...................................483 C70516 ...................................483 C70517 ...................................483 C70518 ...................................483 C70519 ...................................483 C70520 ...................................483 C70521 ...................................483 C70522 ...................................483 C70523 ...................................483 C70524 ...................................483 C70525 ...................................483 C70526 ...................................484 C70527 ...................................484 C70528 ...................................484 C70529 ...................................484

C70530 ...................................484 C70531 ...................................484 C70532 ...................................484 C70533 ...................................484 C70534 ...................................484 C70535 ...................................484 C70536 ...................................484 C80001 ............................366, 368 C80002 .......................... 366, 368 C80003 .......................... 366, 368 C80004 ................................. 366 C80005 .......................... 366, 369 C80006 .......................... 366, 369 C80007 .......................... 366, 369 C80008 .......................... 366, 369 C80009 .......................... 367, 370 C80010 .......................... 367, 370 C80011 .......................... 367, 370 C80012 .......................... 367, 371 C80013 .......................... 367, 371 C80014 .......................... 367, 371 C80015 .......................... 367, 371 C80016 .......................... 367, 372 C80017 .......................... 367, 372 C80018 .......................... 367, 372 C80019 .......................... 367, 373 C80020 .......................... 367, 373 C80021 .......................... 367, 373 C80022 ............................367, 373 C80023 ............................367, 374 C80024 ............................367, 374 C80025 ............................367, 374 C80026 ............................367, 374 C80027 ............................367, 375 C80028 ............................367, 375 C80029 ............................367, 375 C80030 ............................367, 376 C80031 ............................367, 376 C80032 ............................367, 376 C80033 ............................367, 376 C80034 ............................368, 377 C80035 ............................368, 377 C80036 ............................368, 377 C80037 ............................368, 377 C80038 ............................368, 378 C80039 ............................368, 378 C8004 .....................................368 C80040 ............................368, 378 C90001 ...................................445 C90002 ...................................445 C90003 ...................................445 C90004 ...................................445 C90005 ...................................445 C90006 ...................................445 C90007 ...................................445 C90101 ............................335, 337 C90102 ............................335, 337 C90103 ............................335, 337 C90104 ............................335, 338 C90201 ...................................338 C90301 ...................................339

Page 576: 12 ZXG10 BSS(V2.95)OperationManual(PerformanceMeasurementCou

ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

562 Confidential and Proprietary Information of ZTE CORPORATION

C90401 ...................................340 C90402 ...................................340 C90403 ...................................340 C90404 ...................................340 C90501 ...................................340 C90502 ...................................340 C90503 ...................................340 C90504 ...................................340

C90505 ...................................340 C90506 ...................................340 C90507 ...................................340 C90508 ...................................340 C90509 ...................................340 C90510 ...................................341 C90511 ...................................341


Recommended